<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Fluke | Kouei Japan Trading | Get Quotation</title>
	<atom:link href="https://koueitrading.com/global/product-cat/fluke/feed/" rel="self" type="application/rss+xml" />
	<link>https://koueitrading.com/global</link>
	<description>Purchase tools and equipments made in Japan</description>
	<lastBuildDate>Fri, 08 May 2026 02:14:57 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.5</generator>

<image>
	<url>https://koueitrading.com/global/wp-content/uploads/2018/01/cropped-KoueiVietnam-logo-32x32.png</url>
	<title>Fluke | Kouei Japan Trading | Get Quotation</title>
	<link>https://koueitrading.com/global</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Fluke 908/909 Frequency Standard</title>
		<link>https://koueitrading.com/global/product/fluke-908-909-frequency-standard/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Fri, 23 Oct 2020 04:10:40 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=127868</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 908/909 Features Accurate reference &#8220;atomic clock&#8221; for automated test systems Affordable and extremely economical Optional carrying case for portability No battery backup required during transport Short warm-up time Specifications Parameter Details Basic model 5&#215;10 MHz, 1&#215;5 MHz: Sine wave &#62;0.6V rms, 50Ω With option 70 10&#215;10 MHz, 1&#215;5 MHz: Sine wave [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-908-909-frequency-standard/">Fluke 908/909 Frequency Standard</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 908/909</p>
<h2 class="features-title">Features</h2>
<ul>
<li>Accurate reference &#8220;atomic clock&#8221; for automated test systems</li>
<li>Affordable and extremely economical</li>
<li>Optional carrying case for portability</li>
<li>No battery backup required during transport</li>
<li>Short warm-up time</li>
</ul>
<p><img decoding="async" class="aligncenter wp-image-127872 size-full" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-23-111901.png" alt="908/909" width="330" height="129" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-23-111901.png 330w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-23-111901-300x117.png 300w" sizes="(max-width: 330px) 100vw, 330px" /></p>
<h2>Specifications</h2>
<table>
<thead>
<tr>
<th><strong>Parameter</strong></th>
<th><strong>Details</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td style="text-align: center;"><strong>Basic model</strong></td>
<td style="text-align: center;">5&#215;10 MHz, 1&#215;5 MHz: Sine wave &gt;0.6V rms, 50Ω</td>
</tr>
<tr>
<td style="text-align: center;"><strong>With option 70</strong></td>
<td style="text-align: center;">10&#215;10 MHz, 1&#215;5 MHz: Sine wave &gt;0.6V rms, 50Ω</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Frequency Stability (1 month)</strong></td>
<td style="text-align: center;">908: 3&#215;10⁻⁹, 909: 5&#215;10⁻¹¹</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Frequency Stability (1 year)</strong></td>
<td style="text-align: center;">908: &lt; 2&#215;10⁻⁸ (1 year), 909: 1&#215;10⁻⁹ (10 years)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Temperature Environment (20°C &#8211; 26°C)</strong></td>
<td style="text-align: center;">908: &lt; 4&#215;10⁻¹⁰ typical, 909: 2&#215;10⁻¹¹ typical value</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Temperature Environment (0°C &#8211; 50°C)</strong></td>
<td style="text-align: center;">908: 2.5&#215;10⁻⁹, 909: 3&#215;10⁻¹⁰</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Short-term stability (10s)</strong></td>
<td style="text-align: center;">908: 5&#215;10⁻¹², 909: 1&#215;10⁻¹¹</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Short-term stability (1s)</strong></td>
<td style="text-align: center;">908: 5&#215;10⁻¹², 909: 3&#215;10⁻¹¹</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Warm up time (+25°C)</strong></td>
<td style="text-align: center;">908: 10 minutes to 5&#215;10⁻⁹, 909: 5.4 minutes to lock</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Operating temperature</strong></td>
<td style="text-align: center;">0°C to +50°C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Storage temperature</strong></td>
<td style="text-align: center;">-40°C to +70°C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Safety standards</strong></td>
<td style="text-align: center;">EN 61010-1, CE compliant</td>
</tr>
<tr>
<td style="text-align: center;"><strong>EMI standards</strong></td>
<td style="text-align: center;">EN 55011 ISM group, class B, EN 50082-2, CE compliant</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Power consumption (908)</strong></td>
<td style="text-align: center;">&lt;20W during warm-up, &lt;7W continuous</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Power consumption (909)</strong></td>
<td style="text-align: center;">&lt;70W during warm-up, &lt;30W continuous</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Dimensions</strong></td>
<td style="text-align: center;">315 x 86 x 395 mm</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Weight</strong></td>
<td style="text-align: center;">4.8 kg (unit only), 7.8 kg (shipping)</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-908-909-frequency-standard/">Fluke 908/909 Frequency Standard</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 720A Kelvin-Varley Voltage Divider</title>
		<link>https://koueitrading.com/global/product/fluke-720a-kelvin-varley-voltage-divider/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 22 Oct 2020 08:49:25 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=127726</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 720A Features The Model 720A Kelvin-Varley Divider is a high resolution ratio standard with 0.1 ppm absolute linearity, 0.1 ppm/°C temperature coefficient and self-calibration capability. Resolution 0.1 ppm, 7 digits Absolute Input Linearity 0.1 ppm Built-in self-calibration bridge Self-calibration possible from the front panel Specification Specification Details Ratio Range 0:1.1 Input [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-720a-kelvin-varley-voltage-divider/">Fluke 720A Kelvin-Varley Voltage Divider</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 720A</p>
<h2 class="features-title">Features</h2>
<p><span class="PrdPlainText">The Model 720A Kelvin-Varley Divider is a high resolution ratio standard with 0.1 ppm absolute linearity, 0.1 ppm/°C temperature coefficient and self-calibration capability.</span></p>
<ul>
<li>Resolution 0.1 ppm, 7 digits</li>
<li>Absolute Input Linearity 0.1 ppm</li>
<li>Built-in self-calibration bridge</li>
<li>Self-calibration possible from the front panel</li>
</ul>
<p><img decoding="async" class="aligncenter wp-image-127731 size-full" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-155939.png" alt="720A" width="323" height="132" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-155939.png 323w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-155939-300x123.png 300w" sizes="(max-width: 323px) 100vw, 323px" /></p>
<h2>Specification</h2>
<table class="dataframe" border="1">
<thead>
<tr style="text-align: right;">
<th style="text-align: center;">Specification</th>
<th style="text-align: center;">Details</th>
</tr>
</thead>
<tbody>
<tr>
<td style="text-align: center;">Ratio Range</td>
<td style="text-align: center;">0:1.1</td>
</tr>
<tr>
<td style="text-align: center;">Input Range</td>
<td style="text-align: center;">0V to 1100V</td>
</tr>
<tr>
<td style="text-align: center;">Resolution</td>
<td style="text-align: center;">0.1 ppm of input, 7 digits</td>
</tr>
<tr>
<td style="text-align: center;">Terminal Linearity</td>
<td style="text-align: center;">±0.1 ppm</td>
</tr>
<tr>
<td style="text-align: center;">Size</td>
<td style="text-align: center;">14 cm H x 48.2 cm W x 33 cm D, rack mount (5.5 in H x 19 in W x 13 in D)</td>
</tr>
<tr>
<td style="text-align: center;">Weight</td>
<td style="text-align: center;">8.16 kg (18 lbs)</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/fluke-720a-kelvin-varley-voltage-divider/">Fluke 720A Kelvin-Varley Voltage Divider</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 792A AC/DC Transfer Standard</title>
		<link>https://koueitrading.com/global/product/fluke-792a-ac-dc-transfer-standard/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 22 Oct 2020 08:30:30 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=127711</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 792A Features The 792A is an ultra-high accuracy AC/DC thermal transfer standard designed to meet the most demanding AC measurement requirements. It uses Fluke&#8217;s patented RMS sensor and thin film range resistors to achieve outstanding transfer accuracy with a total uncertainty of ±10 ppm The 792A has a voltage range of [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-792a-ac-dc-transfer-standard/">Fluke 792A AC/DC Transfer Standard</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 792A</p>
<h2 class="features-title">Features</h2>
<ul>
<li>The 792A is an ultra-high accuracy AC/DC thermal transfer standard designed to meet the most demanding AC measurement requirements.</li>
<li>It uses Fluke&#8217;s patented RMS sensor and thin film range resistors to achieve outstanding transfer accuracy with a total uncertainty of ±10 ppm</li>
<li>The 792A has a voltage range of 2 mV to 1000 V and a frequency range of 10 Hz to 1 MHz.</li>
</ul>
<p><img decoding="async" class="aligncenter wp-image-127724 size-full" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-154604.png" alt="792A" width="211" height="172" /></p>
<h2>Specification</h2>
<table class="dataframe" border="1">
<thead>
<tr style="text-align: right;">
<th style="text-align: center;">Specification</th>
<th style="text-align: center;">Details</th>
</tr>
</thead>
<tbody>
<tr>
<td style="text-align: center;">AC-DC Differential</td>
<td style="text-align: center;">Range: 2mV to 1000V, 10Hz to 1MHz<br />
Best 1 year specification: ±10 ppm</td>
</tr>
<tr>
<td style="text-align: center;">Temperature Stability</td>
<td style="text-align: center;">12 hours are required for stability in the operating environment.</td>
</tr>
<tr>
<td style="text-align: center;">Warm-up Time</td>
<td style="text-align: center;">After stabilization time, leave the power on for 15 minutes.</td>
</tr>
<tr>
<td style="text-align: center;">Temperature Performance</td>
<td style="text-align: center;">Action: 11°C to 35°C<br />
During calibration: 18°C to 28°C<br />
Storage: -40°C to 50°C</td>
</tr>
<tr>
<td style="text-align: center;">Relative humidity</td>
<td style="text-align: center;">Action: &lt;75% at ~30°C, &lt;70% at ~35°C<br />
Storage: &lt;95%, non-condensing</td>
</tr>
<tr>
<td style="text-align: center;">Altitude</td>
<td style="text-align: center;">Action: up to 3,050 m (10,000 ft)<br />
Non-operating: Up to 12,200 m (40,000 ft)</td>
</tr>
<tr>
<td style="text-align: center;">Input Lo side insulation</td>
<td style="text-align: center;">20V to chassis</td>
</tr>
<tr>
<td style="text-align: center;">Guard Insulation</td>
<td style="text-align: center;">10V to input LO or chassis</td>
</tr>
<tr>
<td style="text-align: center;">EMI/RFI</td>
<td style="text-align: center;">FCC Rules Part 15, Subpart J, Class B, VDE 0871, Class B, VDE 0875, Class K</td>
</tr>
<tr>
<td style="text-align: center;">Reliability</td>
<td style="text-align: center;">MIL-STD-28800D, paragraph 3.13.3</td>
</tr>
<tr>
<td style="text-align: center;">Power supply</td>
<td style="text-align: center;">50 Hz to 60 Hz ±5%, Voltage selection 100 V, 120 V, 220 V, 240 V ±10%</td>
</tr>
<tr>
<td style="text-align: center;">Size</td>
<td style="text-align: center;">Transfer Unit: 17.8cm H x 21.6cm W x 30.5cm D<br />
Power Pack: 17.8cm H x 21.6cm W x 30.5cm D<br />
1000V Range Resistor: Height 7.6 cm x Width 8.9 cm x Depth 14.0 cm<br />
Transfer Switch: Height 7.6 cm x Width 8.9 cm x Depth 14.0 cm</td>
</tr>
<tr>
<td style="text-align: center;">Weight</td>
<td style="text-align: center;">Transfer Unit: 8.4 kg<br />
Power Pack: 8.9 kg<br />
1000V Range Resistor: 1.6 kg<br />
Transfer Switch: 1.6 kg</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-792a-ac-dc-transfer-standard/">Fluke 792A AC/DC Transfer Standard</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 732C/ 734C DC Voltage Standards</title>
		<link>https://koueitrading.com/global/product/fluke-732c-734c-dc-voltage-standards/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 22 Oct 2020 08:22:31 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=127702</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 732C / 734C Features The Fluke 732C DC Standard is a RoHS compliant direct current voltage standard ideal for maintaining voltages in primary and secondary standard laboratories. The 732C voltage standards provide outputs of 10 V, 1 V, and 0.1 V, respectively, making them ideal for managing standards in the calibration [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-732c-734c-dc-voltage-standards/">Fluke 732C/ 734C DC Voltage Standards</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 732C / 734C</p>
<h2 class="features-title">Features</h2>
<ul>
<li>The Fluke 732C DC Standard is a RoHS compliant direct current voltage standard ideal for maintaining voltages in primary and secondary standard laboratories.</li>
<li>The 732C voltage standards provide outputs of 10 V, 1 V, and 0.1 V, respectively, making them ideal for managing standards in the calibration lab or for easy transport to remote locations.</li>
<li>The 734C DC voltage standard consists of four electrically and mechanically independent 732C DC standards housed in a rack-sized enclosure.</li>
<li>Base and special models are available, with the special model providing twice the stability of the base model.</li>
</ul>
<p><img loading="lazy" decoding="async" class="alignleft wp-image-127704" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-152402.png" alt="732C / 734C" width="334" height="207" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-152402.png 676w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-152402-300x186.png 300w" sizes="auto, (max-width: 334px) 100vw, 334px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-127705" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-152407.png" alt="732C / 734C" width="262" height="224" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-152407.png 631w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-152407-300x257.png 300w" sizes="auto, (max-width: 262px) 100vw, 262px" /></p>
<h2>Specifications</h2>
<h3>Mains power</h3>
<p>Table 1 shows the available AC power sources. The AC current draw at 120V AC is 0.13A (typical). Table 1: Mains Power Sources</p>
<table class="table" border="1" cellspacing="0" cellpadding="5">
<tbody>
<tr>
<th>732C AC voltage settings</th>
<th>Usable AC voltage</th>
<th>Available frequencies</th>
</tr>
<tr>
<td style="text-align: center;">100V</td>
<td style="text-align: center;">90V to 110V</td>
<td style="text-align: center;">50Hz/60Hz</td>
</tr>
<tr>
<td style="text-align: center;">120V</td>
<td style="text-align: center;">108V to 132V</td>
<td style="text-align: center;">50Hz/60Hz</td>
</tr>
<tr>
<td style="text-align: center;">220V</td>
<td style="text-align: center;">198V to 242V</td>
<td style="text-align: center;">50Hz/60Hz</td>
</tr>
<tr>
<td style="text-align: center;">240V</td>
<td style="text-align: center;">216V to 264V</td>
<td style="text-align: center;">50Hz/60Hz</td>
</tr>
</tbody>
</table>
<table class="table" border="1" cellspacing="0" cellpadding="5">
<tbody>
<tr>
<td style="text-align: center;" rowspan="2"><strong>battery</strong></td>
<td style="text-align: center;">Battery operation</td>
<td style="text-align: center;">The product will operate for at least 72 hours on a full charge (at 23 ±5 °C, with a total current drain at the outputs of 0 mA to 0.1 mA).</td>
</tr>
<tr>
<td style="text-align: center;">Charging time</td>
<td style="text-align: center;">Up to 36 hours (with built-in automatic charger)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>External DC Input</strong></td>
<td style="text-align: center;" colspan="2">The Product can be powered indefinitely through the rear panel input terminals (12 V DC to 15 V DC). The DC power source must be rated ≥300 mA.</td>
</tr>
<tr>
<td style="text-align: center;"><strong>insulation</strong></td>
<td style="text-align: center;" colspan="2">The resistance from any terminal of this product to earth (chassis) ground or to the AC power source is greater than 10,000 MΩ, shunted by less than 1,000 pF.</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Guard and Ground Terminals</strong></td>
<td style="text-align: center;" colspan="2">Chassis ground connections are provided on both the front and rear panels, and an internal guard is accessible through a front panel terminal.</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Output Protection</strong></td>
<td colspan="2">All outputs can be shorted indefinitely without damage to the unit. The 10 V output can withstand voltages from other sources as follows:For voltages ≤220 V DC, the Product is protected for a maximum continuous current of 50 mA.<br />
For voltages ≤1100 V DC, the Product is protected for short periods against up to 25 mA continuous current or 0.6 Joules.</td>
</tr>
</tbody>
</table>
<table class="table" border="1" cellspacing="0" cellpadding="5">
<tbody>
<tr>
<th colspan="2">environment</th>
</tr>
<tr>
<td style="text-align: center;" rowspan="3"><strong>When operating within specifications</strong></td>
<td style="text-align: center;">Temperature range: 15 °C to 35 °C</td>
</tr>
<tr>
<td style="text-align: center;">Relative humidity: 0% to 90% up to 28°C, 80% up to 35°C, 50% up to 50°C, non-condensing</td>
</tr>
<tr>
<td style="text-align: center;">Altitude: 0 m to 1830 m (0 ft to 6000 ft)</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="3"><strong>When operating outside specifications</strong></td>
<td style="text-align: center;">Temperature range: 0 °C to 50 °C</td>
</tr>
<tr>
<td style="text-align: center;">Relative humidity: 0% to 90%, non-condensing</td>
</tr>
<tr>
<td style="text-align: center;">Altitude: 0 m to 3,050 m (0 ft to 10,000 ft)</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="3"><strong>During storage (battery removed)</strong></td>
<td style="text-align: center;">Temperature range: -40°C to 50°C</td>
</tr>
<tr>
<td style="text-align: center;">Relative humidity: non-condensing</td>
</tr>
<tr>
<td style="text-align: center;">Altitude: 0m to 12 200m (0ft to 40 000ft)</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-732c-734c-dc-voltage-standards/">Fluke 732C/ 734C DC Voltage Standards</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 5790B AC Measurement Standard</title>
		<link>https://koueitrading.com/global/product/fluke-5790b-ac-measurement-standard/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 22 Oct 2020 08:11:34 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=127695</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 5790B Features The 5790B can use alone or as a transfer standard for external AC/DC sources. In either case, the tedious switching and calculations are perform automatically by the 5790B the resulting AC/DC difference is display directly on the easy-to-read 6.5 inch color touchscreen display. Specifications Summary Specifications AC/DC voltage Best [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-5790b-ac-measurement-standard/">Fluke 5790B AC Measurement Standard</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 5790B</p>
<h2 class="features-title">Features</h2>
<div id="product-accessory-quicktabs">
<div id="quicktabs-product_details" class="quicktabs_wrapper quicktabs-style-nostyle quicktabs-processed">
<div id="quicktabs_container_product_details" class="quicktabs_main quicktabs-style-nostyle">
<div id="quicktabs_tabpage_product_details_0" class="quicktabs_tabpage">
<div class="view view-product-details view-id-product_details view-display-id-block_3 view-dom-id-2 view-product-details view-id-product_details view-display-id-block_3 view-dom-id-2">
<div class="view-content">
<div class="views-row views-row-1 views-row-odd views-row-first views-row-last">
<div class="views-field-field-product-highlights-value">
<div class="field-content">
<ul>
<li>The 5790B can use alone or as a transfer standard for external AC/DC sources.</li>
<li>In either case, the tedious switching and calculations are perform automatically by the 5790B</li>
<li>the resulting AC/DC difference is display directly on the easy-to-read 6.5 inch color touchscreen display.</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-127697" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-151525.png" alt="5790B" width="633" height="351" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-151525.png 763w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-151525-300x166.png 300w" sizes="auto, (max-width: 633px) 100vw, 633px" /></p>
<h2><strong>Specifications</strong></h2>
<table class="table" border="1" cellspacing="0" cellpadding="5">
<tbody>
<tr>
<td colspan="2" bgcolor="#dde6ed"><strong>Summary Specifications</strong></td>
</tr>
<tr>
<td style="text-align: center;" width="150">AC/DC voltage</td>
<td style="text-align: center;" width="420">
<p data-pm-slice="0 0 []">Best 99%, Absolute Specifications:  ± 24 ppm (1 year, 23 °C to ± 5 °C)</p>
</td>
</tr>
<tr>
<td style="text-align: center;">input</td>
<td>
<p style="text-align: center;">Input 1: 600 µV ~ 1000 V (5% over-range)<br />
Input 2: 600 µV ~ 1000 V (5% over-range)<br />
Aux: 250mV ~ 500mV<br />
Wideband input: &lt;7 V rms wideband</p>
</td>
</tr>
<tr>
<td style="text-align: center;">Warm-up time</td>
<td style="text-align: center;">30 minutes</td>
</tr>
<tr>
<td style="text-align: center;">Relative humidity</td>
<td>
<p style="text-align: center;">Operation: 45% to 50 °C 75% to 45 °C 95% to 30 °C<br />
Storage: &lt;95% non-condensing</p>
</td>
</tr>
<tr>
<td style="text-align: center;">Altitude</td>
<td style="text-align: center;">Operating: 3,050 m (10,000 feet)<br />
Non-operating: 12,200 m (40,000 feet)</td>
</tr>
<tr>
<td style="text-align: center;">temperature</td>
<td>
<p style="text-align: center;">Operating: 0 °C to °50 °C<br />
Calibration: 15 °C to 35 °C<br />
Storage: -40 °C to 70 °C</p>
</td>
</tr>
<tr>
<td colspan="2" bgcolor="#dde6ed"><strong>EMC Compliance</strong></td>
</tr>
<tr>
<td style="text-align: center;">International Standards</td>
<td style="text-align: center;">IEC 61326-1: Controlled Electromagnetic Environment &#8211; CISPR 11: Group 1, Class A</td>
</tr>
<tr>
<td style="text-align: center;">Korea (KCC)</td>
<td style="text-align: center;">Class A Equipment (Industrial Broadcasting &amp; Communication Equipment)</td>
</tr>
<tr>
<td style="text-align: center;">United States (FCC)</td>
<td style="text-align: center;">47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.</td>
</tr>
<tr>
<td style="text-align: center;">surge</td>
<td style="text-align: center;">ANSI C62.41-1980, Category A</td>
</tr>
<tr>
<td style="text-align: center;">Reliability</td>
<td style="text-align: center;">MIL-T-2880D, paragraph 3.13.3</td>
</tr>
<tr>
<td colspan="2" bgcolor="#dde6ed"><strong>General Specifications</strong></td>
</tr>
<tr>
<td style="text-align: center;">size</td>
<td style="text-align: center;">Height: 17.8 cm (7 in) with standard rackmount kit + 1.5 cm (0.6 in)<br />
Width: 43.2 cm (17 in)<br />
Depth: 62 cm (24.8 in)</td>
</tr>
<tr>
<td style="text-align: center;">Maximum power</td>
<td>
<p style="text-align: center;">5790B: 100VA</p>
</td>
</tr>
<tr>
<td style="text-align: center;">weight</td>
<td style="text-align: center;">5790B: 24 kg (53 lb)<br />
With wideband option: 24.5 kg (54 lb)</td>
</tr>
<tr>
<td style="text-align: center;">power supply</td>
<td>
<p style="text-align: center;">50Hz or 60Hz; 100V &#8211; 120V, 220V &#8211; 240V<br />
100V, 110V, 115V, 120V, 200V, 220V, 230V, 240V</p>
</td>
</tr>
<tr>
<td style="text-align: center;">Safety standards</td>
<td style="text-align: center;">Compliant with UL1244, IEC 348-1976, IEC 1010, CSA C22.2 No. 231, ANSI/ISA S82</td>
</tr>
<tr>
<td style="text-align: center;">Remote Interface</td>
<td style="text-align: center;">RS-232, IEEE-488, USB, Ethernet</td>
</tr>
<tr>
<td style="text-align: center;">Confidence level</td>
<td style="text-align: center;">99% unless otherwise specified</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>The post <a href="https://koueitrading.com/global/product/fluke-5790b-ac-measurement-standard/">Fluke 5790B AC Measurement Standard</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 8588A Reference Multimeter</title>
		<link>https://koueitrading.com/global/product/fluke-8588a-reference-multimeter/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 22 Oct 2020 08:06:26 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=127690</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 8588A Features The 8588A Reference Multimeter is designed for calibration and metrology laboratories that require the highest stability to make the most accurate measurements while maintaining maximum confidence in traceability. Specifications 8588A 8558A DC voltage 100mV to 1000V 100mV to 1000V AC voltage 10 mV to 1000 V, 1 Hz to 10 [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-8588a-reference-multimeter/">Fluke 8588A Reference Multimeter</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 8588A</p>
<h2 class="features-title">Features</h2>
<p>The 8588A Reference Multimeter is designed for calibration and metrology laboratories that require the highest stability to make the most accurate measurements while maintaining maximum confidence in traceability.</p>
<h2><img loading="lazy" decoding="async" class="aligncenter wp-image-127692" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-150747.png" alt="8588A" width="279" height="428" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-150747.png 435w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-150747-195x300.png 195w" sizes="auto, (max-width: 279px) 100vw, 279px" /></h2>
<h2>Specifications</h2>
<table class="table" border="1" cellspacing="0" cellpadding="5">
<tbody>
<tr>
<th></th>
<th><strong>8588A</strong></th>
<th><strong>8558A</strong></th>
</tr>
<tr>
<td style="text-align: center;"><strong>DC voltage</strong></td>
<td style="text-align: center;">100mV to 1000V</td>
<td style="text-align: center;">100mV to 1000V</td>
</tr>
<tr>
<td style="text-align: center;"><strong>AC voltage</strong></td>
<td style="text-align: center;">10 mV to 1000 V, 1 Hz to 10 MHz</td>
<td style="text-align: center;">10 mV to 1000 V, 1 Hz to 10 MHz</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Resistance, LoI, HV</strong></td>
<td style="text-align: center;">1 Ω to 10 GΩ</td>
<td style="text-align: center;">1 Ω to 10 GΩ</td>
</tr>
<tr>
<td style="text-align: center;"><strong>DC Current</strong></td>
<td style="text-align: center;">10 µA to 30 A</td>
<td style="text-align: center;">10 µA to 2 A</td>
</tr>
<tr>
<td style="text-align: center;"><strong>AC current</strong></td>
<td style="text-align: center;">10 µA to 30 A, 1 Hz to 100 kHz</td>
<td style="text-align: center;">10 µA to 2A, 1Hz to 100kHz</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Digital V</strong></td>
<td style="text-align: center;">
<div>100 mV to 1000 V, 5 Megasamples/sec, up to 20</div>
<div>MHz BW</div>
</td>
<td>
<div style="text-align: center;">100 mV to 1000 V, 5 Megasamples/sec, up to 20</div>
<div style="text-align: center;">MHz BW</div>
</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Digitize I</strong></td>
<td style="text-align: center;">
<div>10 µA to 30 A, 5 Megasamples/sec, up to 4 MHz BW</div>
</td>
<td style="text-align: center;">
<div>10 µA to 2 A, 5 Megasamples/sec,</div>
<div>Up to 4MHz BW</div>
</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Frequency (V, I, BNC)</strong></td>
<td style="text-align: center;">1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz</td>
<td style="text-align: center;">1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz</td>
</tr>
<tr>
<td style="text-align: center;"><strong>temperature</strong></td>
<td style="text-align: center;">PRT / Thermocouple (ext. CJC)</td>
<td style="text-align: center;">PRT / Thermocouple (ext. CJC)</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-8588a-reference-multimeter/">Fluke 8588A Reference Multimeter</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 8558A 8.5 Digit Digital Multimeter</title>
		<link>https://koueitrading.com/global/product/fluke-8558a-8-5-digit-digital-multimeter/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 22 Oct 2020 07:53:32 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=127680</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 8558A Features The 8558A 8.5-digit multimeter delivers high-resolution digitization at 5 MS/s, ideal for lab and production automation. Fluke&#8217;s high-speed system design offers the fastest direct digitization, significantly improving throughput in automated systems requiring speed and precision. An intuitive interface with nine functions and a color display ensures top accuracy across [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-8558a-8-5-digit-digital-multimeter/">Fluke 8558A 8.5 Digit Digital Multimeter</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 8558A</p>
<h2 class="features-title">Features</h2>
<ul>
<li>The 8558A 8.5-digit multimeter delivers high-resolution digitization at 5 MS/s, ideal for lab and production automation.</li>
<li>Fluke&#8217;s high-speed system design offers the fastest direct digitization, significantly improving throughput in automated systems requiring speed and precision.</li>
<li>An intuitive interface with nine functions and a color display ensures top accuracy across a wide measurement range.</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-127684" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-145943.png" alt="8558A " width="524" height="307" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-145943.png 1113w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-145943-300x176.png 300w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-145943-1024x600.png 1024w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-145943-768x450.png 768w" sizes="auto, (max-width: 524px) 100vw, 524px" /></p>
<h2>Specifications</h2>
<table class="table" border="1" cellspacing="0" cellpadding="5">
<tbody>
<tr>
<th></th>
<th><strong><span>8558A</span></strong></th>
<th><strong><span>8588A</span></strong></th>
</tr>
<tr>
<td style="text-align: center;"><strong><span>DC voltage</span></strong></td>
<td style="text-align: center;"><span>100mV to 1000V</span></td>
<td style="text-align: center;"><span>100mV to 1000V</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>AC voltage</span></strong></td>
<td style="text-align: center;"><span>10 mV to 1000 V, 1 Hz to 10 MHz</span></td>
<td style="text-align: center;"><span>10 mV to 1000 V, 1 Hz to 10 MHz</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>Resistance, LoI, HV</span></strong></td>
<td style="text-align: center;"><span>1 Ω to 10 GΩ</span></td>
<td style="text-align: center;"><span>1 Ω to 10 GΩ</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>DC Current</span></strong></td>
<td style="text-align: center;"><span>10 µA to 2 A</span></td>
<td style="text-align: center;"><span>10 µA to 30 A</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>AC current</span></strong></td>
<td style="text-align: center;"><span>10 µA to 2A, 1Hz to 100kHz</span></td>
<td style="text-align: center;"><span>10 µA to 30 A, 1 Hz to 100 kHz</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>Digital V</span></strong></td>
<td style="text-align: center;"><span>Same</span><span> 100 mV to 1000 V, 5 Megasamples/sec, up to 20 MHz BW</span></td>
<td style="text-align: center;"><span>100 mV to 1000 V, 5 Megasamples/sec, up to 20 MHz BW</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>Digitize I</span></strong></td>
<td style="text-align: center;">
<div><span>10 µA to 2 A, 5 Megasamples/sec,</span></div>
<div><span>Up to 4MHz BW</span></div>
</td>
<td style="text-align: center;"><span>10 µA to 30 A, 5 Megasamples/sec, up to 4 MHz BW</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>Frequency (V, I, BNC)</span></strong></td>
<td style="text-align: center;"><span>1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz</span></td>
<td style="text-align: center;"><span>1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>temperature</span></strong></td>
<td style="text-align: center;"><span>PRT / Thermocouple (ext. CJC)</span></td>
<td style="text-align: center;"><span>PRT / Thermocouple (ext. CJC)</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>Capacitance</span></strong></td>
<td style="text-align: center;"><span>none</span></td>
<td style="text-align: center;"><span>1nF to 100mF</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>RF Power</span></strong></td>
<td style="text-align: center;"><span>none</span></td>
<td style="text-align: center;"><span>R&amp;S NRP Series</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>Ext. DC Current and AC Current</span></strong></td>
<td style="text-align: center;"><span>none</span></td>
<td style="text-align: center;"><span>A40B Current Shunts and Other Shunts</span></td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-8558a-8-5-digit-digital-multimeter/">Fluke 8558A 8.5 Digit Digital Multimeter</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 1620A Digital Thermo-Hygrometer DewK</title>
		<link>https://koueitrading.com/global/product/fluke-1620a-digital-thermo-hygrometer-dewk/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 22 Oct 2020 07:26:50 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=127663</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 1620A Features Excellent accuracy Network connection possible Effective Record Analysis Tool Two interchangeable calibrated sensors Large capacity memory Upgraded Software Specification specification Operating range  0 °C to 50 °C; 0% RH to 100% RH Calibration Temperature Accuracy (“H” model)  ± 0.125 °C (16 °C to 24 °C Calibration Temperature Accuracy (“S” Model) [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-1620a-digital-thermo-hygrometer-dewk/">Fluke 1620A Digital Thermo-Hygrometer DewK</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 1620A</p>
<h2 class="features-title">Features</h2>
<ul>
<li>Excellent accuracy</li>
<li>Network connection possible</li>
<li>Effective Record Analysis Tool</li>
<li>Two interchangeable calibrated sensors</li>
<li>Large capacity memory</li>
<li>Upgraded Software</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-127678 size-full" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-144721.png" alt="1620A" width="575" height="380" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-144721.png 575w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-144721-300x198.png 300w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-144721-180x118.png 180w" sizes="auto, (max-width: 575px) 100vw, 575px" /></p>
<h2>Specification</h2>
<table class="table" border="1" cellspacing="0" cellpadding="4">
<tbody>
<tr>
<td class="bodybold" style="text-align: center;" colspan="2" bgcolor="#dde6ed">specification</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">Operating range</td>
<td class="PrdSpecItem" width="420">
<p style="text-align: center;" data-pm-slice="0 0 []"> 0 °C to 50 °C; 0% RH to 100% RH</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" width="150">
<p style="text-align: center;">Calibration Temperature Accuracy (“H” model)</p>
</td>
<td class="PrdSpecItem" style="text-align: center;" width="420">
<p data-pm-slice="0 0 []"> ± 0.125 °C (16 °C to 24 °C</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">Calibration Temperature Accuracy (“S” Model)</td>
<td class="PrdSpecItem" width="420">
<p style="text-align: center;" data-pm-slice="0 0 []"> ± 0.25 °C (15 °C to 35 °C)</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" width="150">
<p style="text-align: center;">Calibrated relative humidity accuracy (“H” model)</p>
</td>
<td class="PrdSpecItem" style="text-align: center;" width="420">
<p data-pm-slice="0 0 []"> ± 1.5% RH (20% RH to 70% RH)</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">Calibrated relative humidity accuracy (“S” Model)</td>
<td class="PrdSpecItem" width="420">
<p style="text-align: center;" data-pm-slice="0 0 []"> ± 2% RH (20% RH to 70% RH)</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" width="150">
<p style="text-align: center;">Estimated Expected Value  (No warranty)</p>
</td>
<td class="PrdSpecItem" style="text-align: center;" width="420">
<p data-pm-slice="0 0 []"> ±0.5 °C outside calibration range<br />
± 3 % RH outside calibration range</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">Delta Temperature Accuracy</td>
<td class="PrdSpecItem" width="420">
<p style="text-align: center;" data-pm-slice="0 0 []"> ± 0.025 °C for ± 1 ° change in the range 15 °C to 35 °C</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">Temperature resolution</td>
<td class="PrdSpecItem" style="text-align: center;" width="420">
<p data-pm-slice="0 0 []"> Front panel selectable down to 0.001 °C (0.01° for logged data)</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">Delta Humidity Accuracy</td>
<td class="PrdSpecItem" width="420">
<p style="text-align: center;" data-pm-slice="0 0 []"> ± 1.0% RH: ± 5% change in the range of 20% RH to 70% RH</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">Humidity Resolution</td>
<td class="PrdSpecItem" style="text-align: center;" width="420">
<p data-pm-slice="0 0 []"> Front panel selectable down to 0.01% (0.1% for logged data)</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">input</td>
<td class="PrdSpecItem" width="420">
<p style="text-align: center;" data-pm-slice="0 0 []"> Measures temperature and relative humidity with up to two probes, removable, extendable with cable, replaceable, with built-in calibration, assignable 16 character ID (identification number)</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">display</td>
<td class="PrdSpecItem" style="text-align: center;" width="420">
<p data-pm-slice="0 0 []"> 240&#215;128 Graphics Monochrome LCD, password protected, displays temperature/humidity data in graphical, numeric and statistical formats, 16 configurable display settings</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">memory</td>
<td class="PrdSpecItem" width="420">
<p style="text-align: center;" data-pm-slice="0 0 []"> 400,000 records with time stamps</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">alarm</td>
<td class="PrdSpecItem" style="text-align: center;" width="420">
<p data-pm-slice="0 0 []"> Visual, audible and external alarms for temperature, temperature change, RH, RH change and faults (password protected)</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">Alarm Port Output</td>
<td class="PrdSpecItem" width="420">
<p style="text-align: center;" data-pm-slice="0 0 []"> 2.5 mm subminiature plug (normally 0 V, outputs 11-12 V, up to 20 mA when activated)</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">connection</td>
<td class="PrdSpecItem" style="text-align: center;" width="420">
<p data-pm-slice="0 0 []"> Ethernet, RS-232</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">Ethernet</td>
<td class="PrdSpecItem" width="420">
<p style="text-align: center;" data-pm-slice="0 0 []"> RJ45 jack, 10 Base-T or 100 Base-TX; Static or Dynamic (DHCP client) IP address authentication</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">web page</td>
<td class="PrdSpecItem" style="text-align: center;" width="420">
<p data-pm-slice="0 0 []"> Built-in web page interface and functions: device identification, measurements, password-protected device page (can be disabled)</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">attachment</td>
<td class="PrdSpecItem" width="420">
<p style="text-align: center;" data-pm-slice="0 0 []"> Wall mounted (mounting included) or bench mounted</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">power supply</td>
<td class="PrdSpecItem" style="text-align: center;" width="420">
<p data-pm-slice="0 0 []"> 12 V DC from an external 100-240 V AC power adapter</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">Battery Assistance</td>
<td class="PrdSpecItem" width="420">
<p style="text-align: center;" data-pm-slice="0 0 []"> Standard built-in 9 V battery allows measurements even during power outages</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">Dimensions (DewK) ( HxWxD )</td>
<td class="PrdSpecItem" style="text-align: center;" width="420">
<p data-pm-slice="0 0 []"> 125mm x 211mm x 51mm</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">Dimensions (sensor)(Length x diameter)</td>
<td class="PrdSpecItem" width="420">
<p style="text-align: center;" data-pm-slice="0 0 []"> 79mm x 19mm</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">weight</td>
<td class="PrdSpecItem" style="text-align: center;" width="420">
<p data-pm-slice="0 0 []"> 0.7 kg</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">Proofreading</td>
<td class="PrdSpecItem" width="420">
<p style="text-align: center;" data-pm-slice="0 0 []"> NVLAP calibration certificate for temperature and humidity. Data included is for 3 temperature points and 3 humidity points at 20°C. Compliant with NCSL/ISO/IEC 17025:2000 and ANSI/NCSL Z540-1-1994.</p>
</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" width="150">LogWare III (optional software)</td>
<td class="PrdSpecItem" width="420">
<p style="text-align: center;" data-pm-slice="0 0 []"> Requirements: Microsoft® Windows® 2000 (SP4) or XP (SP2), (optional software) IBM compatible Intel Pentium® IV 1 GHz PC processor or higher, 512 MB RAM (1 GB or more recommended), 200 MB HDD space for installation (more is preferred for data storage), CD drive (required for installation)</p>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/fluke-1620a-digital-thermo-hygrometer-dewk/">Fluke 1620A Digital Thermo-Hygrometer DewK</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 2456-LEM Laboratory Environmental Monitor</title>
		<link>https://koueitrading.com/global/product/fluke-2456-lem-laboratory-environmental-monitor/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 22 Oct 2020 07:20:46 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=127656</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 2456-LEM Features Communication via RS-232 or RS-485 Includes software for displaying all parameters, recording data and calibration Accuracy: 0.1 °C, 0.04 inHg (1.3 mbar), 3 % relative humidity Ideal for use in calibration labs, clean rooms, storage facilities or with Ruska piston gauges Instead of mechanical chart recorders Specifications General Specifications [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-2456-lem-laboratory-environmental-monitor/">Fluke 2456-LEM Laboratory Environmental Monitor</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 2456-LEM</p>
<h2 class="features-title">Features</h2>
<ul>
<li><span>Communication via RS-232 or RS-485</span></li>
<li><span>Includes software for displaying all parameters, recording data and calibration</span></li>
<li><span>Accuracy: 0.1 °C, 0.04 inHg (1.3 mbar), 3 % relative humidity</span></li>
<li><span>Ideal for use in calibration labs, clean rooms, storage facilities or with Ruska piston gauges</span></li>
<li><span>Instead of mechanical chart recorders</span></li>
</ul>
<h2><strong>Specifications</strong></h2>
<table class="table" border="1" cellspacing="0" cellpadding="3">
<tbody>
<tr>
<td colspan="2" valign="top"><strong><span>General Specifications</span></strong></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="138"><strong><span>unit</span></strong></td>
<td style="text-align: center;" valign="top" width="474"><strong><span>Temperature:</span></strong><span> °F or °C</span><br />
<strong><span>Pressure:</span></strong><span> mmHg, cmHg, inHg, kPa, mbar, psi, bar, kg/cm2</span><br />
<strong><span>Humidity:</span></strong><span> %RH, </span><strong><span>Air Density:</span></strong><span> g/cm3, kg/m3, lb/in3</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="138"><strong><span>power supply</span></strong></td>
<td style="text-align: center;" valign="top" width="474">
<span>Optional power supply via 10 to 36 V dc, 250 mA max (supplied via 115/230 AC adapter) RS-485.</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="138"><strong><span>Temperature Environment</span></strong></td>
<td style="text-align: center;" valign="top" width="474"><strong><span>Operating</span></strong><span> : 18 °C to 28 °C (64 °F to 82 °F)</span><br />
<strong><span>Storage:</span></strong><span> -20 °C to 70 °C (-4 °F to 158 °F)</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="138"><strong><span>Humidity Environment</span></strong></td>
<td style="text-align: center;" valign="top" width="474"><span>5 % to 95 % RH, non-condensing</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="138"><strong><span>weight</span></strong></td>
<td style="text-align: center;" valign="top" width="474"><span>0.23 kg (0.5 lb)</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="138"><strong><span>size</span></strong></td>
<td style="text-align: center;" valign="top" width="474"><span>(H x W x D) 133.35 mm x 82.55 mm x 31.75 mm (5.25 in x 3.25 in x 1.25 in)</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="138"><strong><span>communication</span></strong></td>
<td style="text-align: center;" valign="top" width="474"><span>RS-232 or RS-485</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="138"><strong><span>Warm-up time</span></strong></td>
<td style="text-align: center;" valign="top" width="474"><span>half an hour</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="138"><strong><span>Data Update</span></strong></td>
<td style="text-align: center;" valign="top" width="474"><span>1 second</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="138"><strong><span>range</span></strong></td>
<td style="text-align: center;" valign="top" width="474"></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="138"><strong><span>Temperature Environment</span></strong></td>
<td style="text-align: center;" valign="top" width="474"><span>18°C to 28°C (64°F to 82°F)</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="138"><strong><span>pressure</span></strong></td>
<td style="text-align: center;" valign="top" width="474"><span>20 inHg to 34 inHg (700 mbar to 1150 mbar)</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="138"><strong><span>Humidity Environment</span></strong></td>
<td style="text-align: center;" valign="top" width="474"><span>5 to 95% RH</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="138"><strong><span>specification</span></strong></td>
<td style="text-align: center;" valign="top" width="474"></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="138"><strong><span>Accuracy</span></strong></td>
<td style="text-align: center;" valign="top" width="474"><strong><span>Temperature</span></strong><span> : ±0.1°C (0.18°F)</span><br />
<strong><span>Pressure:</span></strong><span> ±0.04 inHg (1.3 mbar)</span><br />
<strong><span>Humidity:</span></strong><span> ±3% RH (Accuracy defined as the combined effects of linearity, repeatability and hysteresis)</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="138"><strong><span>Total uncertainty</span></strong></td>
<td style="text-align: center;" valign="top" width="474"><strong><span>Temperature:</span></strong><span> ± 0.5°C (0.9 °F)/year</span><br />
<strong><span>Pressure:</span></strong><span> ± 0.08 inHg (2.7 mbar)/year</span><br />
<strong><span>Humidity:</span></strong><span> ± 10 % RH/year</span></td>
</tr>
<tr>
<td style="text-align: center;" colspan="2" valign="top"><span>Accuracy (uncertainty) formulas follow recommendations from the ISO Guide for Measurement Uncertainty Formulas and include</span><br />
<span>accuracy, stability, temperature effects and RSS for 2 sigma (95%) of the calibration standards .</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="138"><span>software</span></td>
<td style="text-align: center;" valign="top" width="474"><span>Requires Microsoft® Windows® 95 or higher, 1.6 MB free hard disk space,</span><br />
<span>32 MB RAM, RS-232 or RS-485 interface,</span><br />
<span>comprehensive help and system manual included, syntax commands included.</span></td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-2456-lem-laboratory-environmental-monitor/">Fluke 2456-LEM Laboratory Environmental Monitor</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 5128A RapidCal Humidity Calibrator</title>
		<link>https://koueitrading.com/global/product/fluke-5128a-rapidcal-humidity-calibrator/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 22 Oct 2020 07:09:32 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=127648</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 5128A Features Best-in-class system accuracy for reliable humidity probe calibration The time it takes to stabilize at the set humidity and temperature is short, greatly improving work efficiency Supports multi-point calibration of humidity probes at the work site Calibrate multiple humidity probes together Small, lightweight and easy to carry ISO 17025 [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-5128a-rapidcal-humidity-calibrator/">Fluke 5128A RapidCal Humidity Calibrator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 5128A</p>
<h2 class="features-title">Features</h2>
<ul>
<li>Best-in-class system accuracy for reliable humidity probe calibration</li>
<li>The time it takes to stabilize at the set humidity and temperature is short, greatly improving work efficiency</li>
<li>Supports multi-point calibration of humidity probes at the work site</li>
<li>Calibrate multiple humidity probes together</li>
<li>Small, lightweight and easy to carry</li>
<li>ISO 17025 accredited calibration included as standard</li>
<li>Easy maintenance</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-127650" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-141214.png" alt="5128A" width="459" height="261" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-141214.png 748w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-141214-300x170.png 300w" sizes="auto, (max-width: 459px) 100vw, 459px" /></p>
<h2>General Specifications</h2>
<table class="table" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="311">
<p style="text-align: center;">AC power supply voltage</p>
</td>
<td style="text-align: center;" valign="top" width="312">100V to 240V ± 10%</td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="311">Power frequency</td>
<td valign="top" width="312">
<p style="text-align: center;">47Hz to 63Hz</p>
</td>
</tr>
<tr>
<td valign="top" width="311">
<p style="text-align: center;">Power Consumption</p>
</td>
<td style="text-align: center;" valign="top" width="312">300VA</td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="311">Usable test liquid</td>
<td valign="top" width="312">
<p style="text-align: center;">Distilled water</p>
</td>
</tr>
<tr>
<td valign="top" width="311">
<p style="text-align: center;">Warm-up time</p>
</td>
<td style="text-align: center;" valign="top" width="312">Twice the previous warm-up time, up to a maximum of 30 minutes</td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="311">Power Fuse Rating</td>
<td style="text-align: center;" valign="top" width="312">F 4A 250V (fast acting)</td>
</tr>
<tr>
<td valign="top" width="311">
<p style="text-align: center;">Operating humidity range, 18 °C to 28 °C</p>
</td>
<td style="text-align: center;" valign="top" width="312">Maximum 80% RH</td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="311">Storage Temperature and Relative Humidity</td>
<td valign="top" width="312">
<p style="text-align: center;">-20 °C to 50 °C, 0 % to 95 % RH, non-condensing</p>
</td>
</tr>
<tr>
<td valign="top" width="311">
<p style="text-align: center;">Power Output</p>
</td>
<td style="text-align: center;" valign="top" width="312">12 V dc, max 1 A, Fuse: F 1A 250V (fast acting)</td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="311">Computer Interface</td>
<td valign="top" width="312">
<p style="text-align: center;">USB</p>
</td>
</tr>
<tr>
<td valign="top" width="311">
<p style="text-align: center;">Safety standards</p>
</td>
<td style="text-align: center;" valign="top" width="312">IEC 61010-1, Installation Category II, Pollution Degree 2, Indoor use only</td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="311">Altitude</td>
<td valign="top" width="312">
<p style="text-align: center;">2000 m</p>
</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-5128a-rapidcal-humidity-calibrator/">Fluke 5128A RapidCal Humidity Calibrator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 7526A High Precision Process Calibrator</title>
		<link>https://koueitrading.com/global/product/fluke-7526a-high-precision-process-calibrator/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 22 Oct 2020 06:48:20 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=127636</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 7526A Features DC voltage, current, resistance, RTD, thermocouple output and measurement High-precision pressure measurements using Fluke 700 Series or 525A-P Series pressure modules 24 VDC transmitter loop power supply Measuring 4-20 mA Loop Current Automatic switch test function Reading of platinum resistance thermometers with ITS-90 calibration coefficient Specifications DC voltage, output [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-7526a-high-precision-process-calibrator/">Fluke 7526A High Precision Process Calibrator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 7526A</p>
<h2 class="features-title">Features</h2>
<ul>
<li><span>DC voltage, current, resistance, RTD, thermocouple output and measurement</span></li>
<li><span>High-precision pressure measurements using Fluke 700 Series or 525A-P Series pressure modules</span></li>
<li><span>24 VDC transmitter loop power supply</span></li>
<li><span>Measuring 4-20 mA Loop Current</span></li>
<li><span>Automatic switch test function</span></li>
<li><span>Reading of platinum resistance thermometers with ITS-90 calibration coefficient</span></li>
</ul>
<p><img loading="lazy" decoding="async" class="wp-image-127637 size-full alignleft" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-135009.png" alt="7526A" width="224" height="287" /><img loading="lazy" decoding="async" class="alignnone wp-image-127638 size-full" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-135014.png" alt="7526A" width="390" height="292" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-135014.png 390w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-135014-300x225.png 300w" sizes="auto, (max-width: 390px) 100vw, 390px" /></p>
<h2>Specifications</h2>
<table class="table" border="1" cellspacing="0" cellpadding="4">
<tbody>
<tr>
<td style="text-align: center;" colspan="4" bgcolor="#dde6ed"><strong><span>DC voltage, output</span></strong></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="160"><strong><span>Range  </span><sup><span>[1]</span></sup></strong></td>
<td style="text-align: center;" colspan="2" align="center"><strong><span>Absolute Uncertainty, ±</span><br />
<span>(ppm of output + μV), 1 year</span></strong></td>
<td style="text-align: center;" align="center" valign="top" width="250"><strong><span>resolution</span></strong></td>
</tr>
<tr>
<td style="text-align: center;"><span>0 to 100 mV</span></td>
<td style="text-align: center;" align="center" width="99"><span>30</span></td>
<td style="text-align: center;" align="center" width="99"><span>3</span></td>
<td style="text-align: center;" align="center"><span>1 μV</span></td>
</tr>
<tr>
<td style="text-align: center;"><span>0 to 1 V</span></td>
<td style="text-align: center;" align="center"><span>30</span></td>
<td style="text-align: center;" align="center"><span>10</span></td>
<td style="text-align: center;" align="center"><span>10 μV</span></td>
</tr>
<tr>
<td style="text-align: center;"><span>0 to 10 V</span></td>
<td style="text-align: center;" align="center"><span>30</span></td>
<td style="text-align: center;" align="center"><span>100</span></td>
<td style="text-align: center;" align="center"><span>100 μV</span></td>
</tr>
<tr>
<td style="text-align: center;"><span>0 to 100 V</span></td>
<td style="text-align: center;" align="center"><span>30</span></td>
<td style="text-align: center;" align="center"><span>1 mV</span></td>
<td style="text-align: center;" align="center"><span>1 mV</span></td>
</tr>
<tr>
<td style="text-align: center;" colspan="4"><span>TC Output and Input</span></td>
</tr>
<tr>
<td style="text-align: center;"><span>–10mV to 75mV</span></td>
<td style="text-align: center;" align="center"><span>30</span></td>
<td style="text-align: center;" align="center"><span>2</span></td>
<td style="text-align: center;" align="center"><span>10 Ohms</span></td>
</tr>
</tbody>
</table>
<p><span>[1]</span><span> All outputs are positive unless otherwise noted.</span></p>
<table class="table" border="1" cellspacing="0" cellpadding="4">
<tbody>
<tr>
<td colspan="4" bgcolor="#dde6ed"><strong><span>DC voltage,</span></strong><span> isolated input</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="160"><strong><span>range</span></strong></td>
<td style="text-align: center;" colspan="2" align="center"><strong><span>Absolute Uncertainty, ±</span><br />
<span>(ppm of reading + mV),</span><br />
<span>1 year</span></strong></td>
<td style="text-align: center;" align="center" valign="top" width="250"><strong><span>resolution</span></strong></td>
</tr>
<tr>
<td style="text-align: center;" width="160"><span>0 to 10 V</span></td>
<td style="text-align: center;" align="center" width="99"><span>100</span></td>
<td style="text-align: center;" align="center" width="99"><span>0.2</span></td>
<td style="text-align: center;" align="center"><span>100 μV</span></td>
</tr>
<tr>
<td style="text-align: center;" width="160"><span>10V to 100V</span></td>
<td style="text-align: center;" align="center" width="99"><span>100</span></td>
<td style="text-align: center;" align="center"><span>2.0</span></td>
<td style="text-align: center;" align="center"><span>1 mV</span></td>
</tr>
</tbody>
</table>
<table class="table" border="1" cellspacing="0" cellpadding="4">
<tbody>
<tr>
<td colspan="4" bgcolor="#dde6ed"><strong><span>DC current, output</span></strong></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="160"><strong><span>Range </span><sup><span>[1]</span></sup></strong></td>
<td style="text-align: center;" colspan="2" align="center"><strong><span>Absolute Uncertainty,</span><br />
<span>± (ppm of reading + μA),</span><br />
<span>1 year</span></strong></td>
<td style="text-align: center;" align="center" valign="top" width="250"><strong><span>resolution</span></strong></td>
</tr>
<tr>
<td style="text-align: center;" width="160"><span>0 to 100mA</span></td>
<td style="text-align: center;" align="center" width="99"><span>50</span></td>
<td style="text-align: center;" align="center" width="99"><span>1</span></td>
<td style="text-align: center;" align="center"><span>1 μA</span></td>
</tr>
</tbody>
</table>
<p><span>[1]</span><span> ±100 ppm </span><span>of reading for line voltages less than 95 V</span></p>
<table class="table" border="1" cellspacing="0" cellpadding="4">
<tbody>
<tr>
<td colspan="4" bgcolor="#dde6ed"><strong><span>DC current, isolated input</span></strong></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="160"><strong><span>range</span></strong></td>
<td style="text-align: center;" colspan="2" align="center"><strong><span>Absolute Uncertainty, ±</span><br />
<span>(ppm of reading + μA),</span><br />
<span>1 year</span></strong></td>
<td style="text-align: center;" align="center" valign="top" width="250"><strong><span>resolution</span></strong></td>
</tr>
<tr>
<td style="text-align: center;" width="160"><span>0mA to 50mA</span></td>
<td style="text-align: center;" align="center" width="99"><span>100</span></td>
<td style="text-align: center;" align="center" width="99"><span>1</span></td>
<td style="text-align: center;" align="center" width="250"><span>0.1 μA</span></td>
</tr>
<tr>
<td style="text-align: center;" width="160"><span>0 mA to 24 mA </span><sup><span>[1][2]</span></sup><span> (loop powered)</span></td>
<td style="text-align: center;" align="center" width="99"><span>100</span></td>
<td style="text-align: center;" align="center" width="99"><span>1</span></td>
<td style="text-align: center;" align="center" width="250"><span>0.1 μA</span></td>
</tr>
</tbody>
</table>
<p><span>[1] Loop power supply: 24 V ±10%</span><br />
<span>[2] HART resistor: 250 Ω ± 3%</span></p>
<table class="table" border="1" cellspacing="0" cellpadding="4">
<tbody>
<tr>
<td colspan="4" bgcolor="#dde6ed"><strong><span>Resistance, Output</span></strong></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="160"><strong><span>range</span></strong></td>
<td style="text-align: center;" align="center" width="99"><strong><span>Absolute Uncertainty,</span><br />
<span>tcal ± 5 °C, ±</span><br />
<span>Ω, 1 year</span></strong></td>
<td style="text-align: center;" align="center" valign="top" width="250"><strong><span>resolution</span></strong></td>
<td style="text-align: center;" align="center" valign="top" width="250"><strong><span>Nominal Current</span></strong></td>
</tr>
<tr>
<td style="text-align: center;" width="160"><span>5 ohms to 400 ohms</span></td>
<td align="center" width="99"><span>0.015</span></td>
<td align="center" width="99"><span>0.001 Ω</span></td>
<td align="center" width="250"><span>1 to 3mA</span></td>
</tr>
<tr>
<td style="text-align: center;" width="160"><span>5 Ω to 4 kΩ</span></td>
<td align="center" width="99"><span>0.3</span></td>
<td align="center" width="99"><span>0.01 Ω</span></td>
<td align="center" width="250"><span>100 μA to 1 mA</span></td>
</tr>
</tbody>
</table>
<table class="table" border="1" cellspacing="0" cellpadding="4">
<tbody>
<tr>
<td colspan="4" bgcolor="#dde6ed"><strong><span>Resistance, Input</span></strong></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="160"><strong><span>range</span></strong></td>
<td style="text-align: center;" colspan="2" align="center"><strong><span>Absolute Uncertainty, ±</span><br />
<span>(ppm of reading + Ω), 1 year</span></strong></td>
<td style="text-align: center;" align="center" valign="top" width="250"><strong><span>resolution</span></strong></td>
</tr>
<tr>
<td style="text-align: center;" width="160"><span>0 Ω to 400 Ω</span></td>
<td align="center" width="99"><span>20</span></td>
<td align="center" width="99"><span>0.004</span></td>
<td align="center" width="250"><span>0.001 Ω</span></td>
</tr>
<tr>
<td style="text-align: center;" width="160"><span>0 Ω to 4 kΩ</span></td>
<td align="center" width="99"><span>20</span></td>
<td align="center" width="99"><span>0.04</span></td>
<td align="center" width="250"><span>0.01 Ω</span></td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-7526a-high-precision-process-calibrator/">Fluke 7526A High Precision Process Calibrator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 9118A High Precision Thermocouple Calibration Furnace</title>
		<link>https://koueitrading.com/global/product/fluke-9118a-high-precision-thermocouple-calibration-furnace/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 22 Oct 2020 06:40:10 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=127627</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 9118A Features High-precision thermocouple calibration furnace with a maximum temperature of 1200°C The Fluke Calibration 9118A Thermocouple Calibration Furnace is a scalable horizontal furnace with a temperature range of 300°C to 1200°C. It for high-temperature calibration of thermocouples in the aerospace, automotive, energy, metals and plastics industries For comparison calibration of [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-9118a-high-precision-thermocouple-calibration-furnace/">Fluke 9118A High Precision Thermocouple Calibration Furnace</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 9118A</p>
<h2 class="features-title">Features</h2>
<h2><span>High-precision thermocouple calibration furnace with a maximum temperature of 1200°C</span></h2>
<ul>
<li><span>The Fluke Calibration 9118A Thermocouple Calibration Furnace is a scalable horizontal furnace with a temperature range of 300°C to 1200°C.</span></li>
<li><span>It for high-temperature calibration of thermocouples in the aerospace, automotive, energy, metals and plastics industries</span></li>
<li><span>For comparison calibration of precious and base metal thermocouples by instrument manufacturers.</span></li>
<li><span>The 9118A meets the demanding requirements for high-temperature thermocouple calibration </span></li>
<li><span>Offers the best-in-class combination of accuracy, reliability and flexibility in a thermocouple calibration furnace.</span></li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-127632 size-full" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-134310.png" alt="9118A" width="396" height="338" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-134310.png 396w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-134310-300x256.png 300w" sizes="auto, (max-width: 396px) 100vw, 396px" /></p>
<h2>Specifications</h2>
<table class="table" border="1" cellspacing="3" cellpadding="0">
<tbody>
<tr>
<td colspan="2" valign="top" bgcolor="#e9eff4"><strong><em><span>General Specifications</span></em></strong></td>
</tr>
<tr>
<td colspan="2" valign="top"><strong><span>Environmental conditions</span></strong></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="243"><strong><span>Operating temperature</span></strong></td>
<td style="text-align: center;" valign="top" width="372"><span>5°C to 40°C</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="243"><strong><span>Storage temperature</span></strong></td>
<td style="text-align: center;" valign="top" width="372"><span>–20°C to 70°C</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="243"><strong><span>Humidity</span></strong></td>
<td style="text-align: center;" valign="top" width="372"><span>Up to 80% below 31°C (decreases linearly to 50% at 40°C)</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="243"><strong><span>Altitude</span></strong></td>
<td style="text-align: center;" valign="top" width="372"><span>&lt;2,000 m (6,562 feet)</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="243"><strong><span>Power Requirements</span></strong></td>
<td style="text-align: center;" valign="top" width="372"><span>230Vac (±10%), 50/60Hz, 20A</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="243"><strong><span>Heater Power</span></strong></td>
<td style="text-align: center;" valign="top" width="372"><span>4000 W at 230 V ac</span></td>
</tr>
<tr>
<td style="text-align: center;" colspan="2" valign="top"><strong><span>Overcurrent Protection</span></strong></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="243"><strong><span>system</span></strong></td>
<td style="text-align: center;" valign="top" width="372"><span>20 A, 250 V (resettable breaker)</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="243"><strong><span>Main Heater Fuse</span></strong></td>
<td style="text-align: center;" valign="top" width="372"><span>F 12A, 250V</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="243"><strong><span>Zone Heater Fuses</span></strong></td>
<td style="text-align: center;" valign="top" width="372"><span>F 12A, 250V</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="243"><strong><span>Computer Interface</span></strong></td>
<td style="text-align: center;" valign="top" width="372"><span>RS-232 and USB</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="243"><strong><span>display</span></strong></td>
<td style="text-align: center;" valign="top" width="372"><span>Monochrome LCD</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="243"><strong><span>Display resolution</span></strong></td>
<td style="text-align: center;" valign="top" width="372"><span>0.1 °C</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="243"><strong><span>Dimensions (H x W x L)</span></strong></td>
<td style="text-align: center;" valign="top" width="372"><span>400mm x 337mm x 700mm</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="243"><strong><span>weight</span></strong></td>
<td style="text-align: center;" valign="top" width="372"><span>29 kg (without heat equalizing block)</span></td>
</tr>
<tr>
<td style="text-align: center;" colspan="2" valign="top"><strong><span>Heat equalizing block (optional)</span></strong></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="243"><strong><span>Block Material</span></strong></td>
<td style="text-align: center;" valign="top" width="372"><span>alumina</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="243"><strong><span>Block Outer Diameter</span></strong></td>
<td style="text-align: center;" valign="top" width="372"><span>37 mm (1.5 in)</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="243"><strong><span>Block Length</span></strong></td>
<td style="text-align: center;" valign="top" width="372"><span>380 mm (15.0 in)</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="243"><strong><span>Well Diameter</span></strong></td>
<td style="text-align: center;" valign="top" width="372"><span>(4 wells total) 6.7 mm (0.26 inch)</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="243"><strong><span>Well Depth</span></strong></td>
<td style="text-align: center;" valign="top" width="372"><span>365 mm (14.4 in)</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top" width="243"><strong><span>weight</span></strong></td>
<td style="text-align: center;" valign="top" width="372"><span>0.84 kg (heat equalizing block only)</span></td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-9118a-high-precision-thermocouple-calibration-furnace/">Fluke 9118A High Precision Thermocouple Calibration Furnace</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 9150 Thermocouple Calibration Furnace</title>
		<link>https://koueitrading.com/global/product/fluke-9150-thermocouple-calibration-furnace/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 22 Oct 2020 06:32:59 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=127616</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 9150 Features Low-cost thermocouple calibration furnace Low price NIST traceable calibration RS-232 standard equipment Specifications General Specifications Temperature range 150°C to 1200°C Display resolution 0.1 ° to 999.9 ° 1 ° above 1000 °C Stability ±0.5 °C Display accuracy ±5 °C Well Diameter 32 mm Well Depth 140 mm (5.5 in); [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-9150-thermocouple-calibration-furnace/">Fluke 9150 Thermocouple Calibration Furnace</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 9150</p>
<h2 class="features-title">Features</h2>
<p>Low-cost thermocouple calibration furnace</p>
<ul>
<li>Low price</li>
<li>NIST traceable calibration</li>
<li>RS-232 standard equipment</li>
</ul>
<h2>Specifications</h2>
<table class="table" border="1" cellspacing="0" cellpadding="5">
<tbody>
<tr bgcolor="#e9eff4">
<td colspan="2">General Specifications</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Temperature range</strong></td>
<td style="text-align: center;">150°C to 1200°C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Display resolution</strong></td>
<td style="text-align: center;">0.1 ° to 999.9 °<br />
1 ° above 1000 °C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Stability</strong></td>
<td style="text-align: center;">±0.5 °C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Display accuracy</strong></td>
<td style="text-align: center;">±5 °C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Well Diameter</strong></td>
<td style="text-align: center;">32 mm</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Well Depth</strong></td>
<td style="text-align: center;">140 mm (5.5 in); (removable insert 101 mm [4 in] + insulation 38 mm [1.5 in])</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Heating time</strong></td>
<td style="text-align: center;">35 minutes to 1200 °C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Cooling Time</strong></td>
<td style="text-align: center;">140 minutes in blocks</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Well-to-well uniformity</strong></td>
<td style="text-align: center;">±2.5 °C (insert “C”, at 1200 °C)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Stability</strong></td>
<td style="text-align: center;">20 min</td>
</tr>
<tr>
<td style="text-align: center;"><strong>power supply</strong></td>
<td style="text-align: center;">115 VAC (±10%), 10.5 A or 230 VAC (±10%), 5.2 A, switchable, 50/60 Hz, 1200 W</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Dimensions (HxWxD)</strong></td>
<td style="text-align: center;">315 x 208 x 315 mm</td>
</tr>
<tr>
<td style="text-align: center;"><strong>weight</strong></td>
<td style="text-align: center;">13 kg</td>
</tr>
<tr>
<td style="text-align: center;"><strong>NIST traceable calibration</strong></td>
<td style="text-align: center;">Data points: 150 °C, 300 °C, 450 °C, 600 °C, 800 °C, 1000 °C, 1200 °C</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-9150-thermocouple-calibration-furnace/">Fluke 9150 Thermocouple Calibration Furnace</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 9011 High Accuracy Dual Well Calibrator</title>
		<link>https://koueitrading.com/global/product/fluke-9011-high-accuracy-dual-well-calibrator/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 22 Oct 2020 06:25:24 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=127609</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 9011 Features Highest temperature range for a single dry well Two blocks per unit; combined temperature range from –30 °C to 670 °C High temperature block and low temperature block are controlled independently Stability ±0.02 °C Hot block allows for simultaneous calibration of up to eight probes Specification specification High temperature [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-9011-high-accuracy-dual-well-calibrator/">Fluke 9011 High Accuracy Dual Well Calibrator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 9011</p>
<h2 class="features-title">Features</h2>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-127610 size-full" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-132655.png" alt="9011" width="361" height="283" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-132655.png 361w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-132655-300x235.png 300w" sizes="auto, (max-width: 361px) 100vw, 361px" /></p>
<h2><span>Highest temperature range for a single dry well</span></h2>
<ul>
<li><span>Two blocks per unit; combined temperature range from –30 °C to 670 °C</span></li>
<li><span>High temperature block and low temperature block are controlled independently</span></li>
<li><span>Stability ±0.02 °C</span></li>
<li><span>Hot block allows for simultaneous calibration of up to eight probes</span></li>
</ul>
<h2>Specification</h2>
<table class="table" border="1" cellspacing="0" cellpadding="4">
<tbody>
<tr bgcolor="#e9eff4">
<td class="tableHead"><span>specification</span></td>
<td class="tableHead" align="center"><strong><span>High temperature block</span></strong></td>
<td class="tableHead" align="center"><strong><span>Low temperature block</span></strong></td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;"><strong><span>range</span></strong></td>
<td style="text-align: center;" align="center"><span>50°C to 670°C</span></td>
<td style="text-align: center;" align="center"><span>–30°C to 140°C</span></td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;"><strong><span>Accuracy</span></strong></td>
<td style="text-align: center;" align="center"><span>± 0.2 °C at 50 °C</span><br />
<span>± 0.4 °C at 400 °C</span><br />
<span>± 0.65 °C at 600 °C</span></td>
<td style="text-align: center;" align="center"><span>± 0.25 °C (insert wells)</span><br />
<span>± 0.65 °C (fixed wells)</span></td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;"><strong><span>Stability</span></strong></td>
<td align="center"><span>± 0.02 °C at 100 °C</span><br />
<span>± 0.06 °C at 600 °C</span></td>
<td align="center"><span>± 0.02 °C at –30 °C</span><br />
<span>± 0.04 °C at 140 °C</span></td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;"><strong><span>Uniformity</span></strong></td>
<td align="center"><span>± 0.2 °C (typical ± 0.05 °C)</span></td>
<td align="center"><span>± 0.05 °C (insert wells)</span><br />
<span>± 0.25 °C (fixed wells)</span></td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;"><strong><span>Well Depth</span></strong></td>
<td style="text-align: center;" align="center"><span>152 mm</span></td>
<td style="text-align: center;" align="center"><span>124 mm</span></td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;"><strong><span>Heating time to maximum temperature</span></strong></td>
<td align="center"><span>half an hour</span></td>
<td align="center"><span>15 min</span></td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;"><strong><span>Cooling Time</span></strong></td>
<td style="text-align: center;" align="center"><span>120 min (660 °C to 100 °C)</span></td>
<td style="text-align: center;" align="center"><span>30 minutes (140°C to –30°C)</span></td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;"><strong><span>Insert Well</span></strong></td>
<td align="center"><span>Holds one insert (insert is replaceable)</span></td>
<td align="center"><span>One exchangeable insert well and four fixed wells (3.2 mm, 4.8 mm x2, 6.35 mm)</span></td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;"><strong><span>Interface</span></strong></td>
<td style="text-align: center;" colspan="2" align="center"><span>RS-232 interface</span></td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;"><strong><span>power supply</span></strong></td>
<td colspan="2" align="center"><span>115 V ac (± 10 %), 8.8 A or 230 V ac (± 10 %), 4.4 A, switchable, 50/60 Hz, 1150 W</span></td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;"><strong><span>Dimensions (HxWxD)</span></strong></td>
<td style="text-align: center;" colspan="2" align="center"><span>292 x 394 x 267 mm</span></td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;"><strong><span>weight</span></strong></td>
<td colspan="2" align="center"><span>16.4 kg</span></td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;"><strong><span>NIST traceable calibration</span></strong></td>
<td align="center"><span>Data points: 50 °C, 100 °C, 200 °C, 300 °C,</span><br />
<span>400 °C, 500 °C, 600 °C, 660 °C</span></td>
<td align="center"><span>Data points: –30 °C, 0 °C, 25 °C, 50 °C, 75 °C,</span><br />
<span>100 °C, 125 °C, 140 °C</span></td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-9011-high-accuracy-dual-well-calibrator/">Fluke 9011 High Accuracy Dual Well Calibrator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 9101 Zero Point Dry Well</title>
		<link>https://koueitrading.com/global/product/fluke-9101-zero-point-dry-well/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 22 Oct 2020 06:18:43 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=127607</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 9101 Features Ice-free zero reference Portable zero point reference for bus quality stability Easy recalibration ensures long-term reliability When the temperature stabilizes, a light will notify you. Cooling by Peltier element Specification specification Temperature range 0 °C Stability ±0.005°C Total instrument error Typical ± 0.02 °C, maximum ± 0.05 °C (at [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-9101-zero-point-dry-well/">Fluke 9101 Zero Point Dry Well</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 9101</p>
<h2 class="features-title">Features</h2>
<h2><span>Ice-free zero reference</span></h2>
<ul>
<li><span>Portable zero point reference for bus quality stability</span></li>
<li><span>Easy recalibration ensures long-term reliability</span></li>
<li><span>When the temperature stabilizes, a light will notify you.</span></li>
<li><span>Cooling by Peltier element</span></li>
</ul>
<h2>Specification</h2>
<table class="table" border="1" cellspacing="0" cellpadding="4">
<tbody>
<tr bgcolor="#e9eff4">
<td class="tableHead" colspan="2"><span>specification</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>Temperature range</span></strong></td>
<td style="text-align: center;"><span>0 °C</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>Stability</span></strong></td>
<td style="text-align: center;"><span>±0.005°C</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>Total instrument</span><br />
<span>error</span></strong></td>
<td style="text-align: center;"><span>Typical ± 0.02 °C, maximum ± 0.05 °C (at ambient temperature 18 to 25 °C)</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>Stabilization Time</span><br />
</strong></td>
<td style="text-align: center;"><span>Approximately 30 minutes</span><br />
<span>(when it stabilizes at 0 °C, the ready lamp lights up)</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>Temperature coefficient</span></strong></td>
<td style="text-align: center;"><span>±0.005°C/°C</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>Dimensions (H x W x D)</span></strong></td>
<td style="text-align: center;"><span>311 x 216 x 150 mm</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>power supply</span><br />
</strong></td>
<td style="text-align: center;"><span>115 VAC (± 10%), 1 A or 230 VAC (± 10%), 0.5 A (specify at time of order),</span><br />
<span>50/60 Hz, 125 W</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>Well Dimensions</span></p>
<p></strong></td>
<td style="text-align: center;"><span>2 wells 6.4 mm diameter x 152 mm depth,</span><br />
<span>1 well 7 mm diameter x 152 mm depth.</span><br />
<span>Smaller diameters are also available with included insert set.</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>weight</span></strong></td>
<td style="text-align: center;"><span>5.4 kg</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>NIST traceable</span><br />
<span>calibration</span></strong></td>
<td style="text-align: center;"><span>Data point: 0 °C</span></td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-9101-zero-point-dry-well/">Fluke 9101 Zero Point Dry Well</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 9170 Series Metrology Well Calibrator</title>
		<link>https://koueitrading.com/global/product/fluke-9170-series-metrology-well-calibrator/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 22 Oct 2020 06:10:14 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=127600</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 9170 Series Features On-site calibration for lab-level accuracy The world&#8217;s most accurate, stable and uniform industrial heat source Immersion depth: up to 203 mm Models with ITS-90 reference temperature probe have an accuracy of ±0.006 °C The four models cover a temperature range of –45 °C to 700 °C Specification specification [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-9170-series-metrology-well-calibrator/">Fluke 9170 Series Metrology Well Calibrator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 9170 Series</p>
<h2>Features</h2>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-127603 " src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-131500.png" alt="9170 Series" width="266" height="353" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-131500.png 417w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-131500-226x300.png 226w" sizes="auto, (max-width: 266px) 100vw, 266px" /></p>
<h2><span>On-site calibration for lab-level accuracy</span></h2>
<ul>
<li><span>The world&#8217;s most accurate, stable and uniform industrial heat source</span></li>
<li><span>Immersion depth: up to 203 mm</span></li>
<li><span>Models with ITS-90 reference temperature probe have an accuracy of ±0.006 °C</span></li>
<li><span>The four models cover a temperature range of –45 °C to 700 °C</span></li>
</ul>
<h2>Specification</h2>
<table class="table" border="1" cellspacing="0" cellpadding="4">
<tbody>
<tr bgcolor="#e9eff4">
<td class="tableHead" style="text-align: center;"><span>specification</span></td>
<td class="tableHead" style="text-align: center;" colspan="4"><strong><span>Built-in reference thermometer</span></strong></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>Temperature range</span></strong></td>
<td style="text-align: center;" colspan="4"><span>–200 °C 962 °C</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>Resistance Range</span></strong></td>
<td style="text-align: center;" colspan="4"><span>0 Ω to 400 Ω, auto-ranging</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong><span>Characteristics</span></strong></td>
<td style="text-align: center;" colspan="4"><span>ITS-90 Subranges 4, 6, 7, 8, 9, 10, 11 Callendar-Van Dusen (CVD): R </span><sub><span>0</span></sub><span> , a, b, d</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong><span>Resistance Accuracy</span></strong></td>
<td style="text-align: center;" colspan="4"><span>0 Ω to 20 Ω: 0.0005 Ω</span><br />
<span>20 Ω to 400 Ω: 25 ppm</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong><span>Temperature accuracy</span><br />
<span>(not including probe uncertainty)</span></strong></td>
<td style="text-align: center;" colspan="2" valign="top"><strong><span>10 Ω PRT:</span></strong><br />
<span>± 0.013 °C at 0 °C</span><br />
<span>0.014 °C at 155 °C</span><br />
<span>± 0.019 °C at 425 °C</span><br />
<span>± 0.028 °C at 700 °C</span></td>
<td style="text-align: center;" colspan="3"><strong><span>25 Ω and 100 Ω PRT:</span></strong><br />
<span>± 0.005 °C at –100 °C</span><br />
<span>± 0.007 °C at 0 °C</span><br />
<span>0.011 °C at 155 °C</span><br />
<span>± 0.013 °C at 225 °C</span><br />
<span>0.019 °C at 425 °C</span><br />
<span>± 0.027 °C at 661 °C</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong><span>Resistance Resolution</span></strong></td>
<td style="text-align: center;" colspan="4"><span>0 Ω to 20 Ω: 0.0001 Ω</span><br />
<span>20 Ω to 400 Ω: 0.001 Ω</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>Measurement interval</span></strong></td>
<td style="text-align: center;" colspan="4"><span>1 second</span></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span>Connecting to a probe</span></strong></td>
<td style="text-align: center;" colspan="4"><span>Shielded 4-wire, 5-pin DIN connector</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong><span>Proofreading</span></strong></td>
<td style="text-align: center;" colspan="4"><span>NVLAP accredited (built-in reference thermometer only), traceable calibration</span></td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-9170-series-metrology-well-calibrator/">Fluke 9170 Series Metrology Well Calibrator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 9103/ 9140 Field Drywell</title>
		<link>https://koueitrading.com/global/product/fluke-9103-9140-field-drywell/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 22 Oct 2020 06:05:58 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=127595</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 9103/ 9140 Features High performance portable calibrator Lightweight and easy to carry Up to ±0.25 °C accuracy RS-232 interface Easy to recalibrate Specification specification 9103  9140  range  –25 °C to 140 °C (at ambient temperature 23 °C) 35°C to 350°C Accuracy  ± 0.25 °C (± 1 °C for holes larger than [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-9103-9140-field-drywell/">Fluke 9103/ 9140 Field Drywell</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 9103/ 9140</p>
<h2 class="features-title">Features</h2>
<h2><span>High performance portable calibrator</span></h2>
<ul>
<li><span>Lightweight and easy to carry</span></li>
<li><span>Up to ±0.25 °C accuracy</span></li>
<li><span>RS-232 interface</span></li>
<li><span>Easy to recalibrate</span></li>
</ul>
<h2>Specification</h2>
<table class="table" border="1" cellspacing="0" cellpadding="5">
<tbody>
<tr bgcolor="#e9eff4">
<td colspan="3"><span>specification</span></td>
</tr>
<tr>
<td valign="top"></td>
<td align="center" valign="top"><b><span>9103 </span></b></td>
<td align="center" valign="top"><b><span>9140 </span></b></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b><span>range </span></b></td>
<td style="text-align: center;" align="center" valign="top"><span>–25 °C to 140 °C</span><br />
<span>(at ambient temperature 23 °C)</span></td>
<td style="text-align: center;" align="center" valign="top"><span>35°C to 350°C</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b><span>Accuracy </span></b></td>
<td align="center" valign="top"><span>± 0.25 °C (± 1 °C for holes larger than 1/4&#8243; [6.35 mm]) </span></td>
<td align="center" valign="top"><span>± 0.5 °C (± 1 °C for holes larger than 1/4&#8243; [6.35 mm]) </span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b><span>Stability </span></b></td>
<td style="text-align: center;" align="center" valign="top"><span>± 0.02 °C at –25 °C</span><br />
<span>± 0.04 °C at 140 °C </span></td>
<td style="text-align: center;" align="center" valign="top"><span>± 0.03 °C at 50 °C</span><br />
<span>± 0.05 °C at 350 °C </span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b><span>Well-to-well uniformity </span></b></td>
<td align="center" valign="top"><span>± 0.1 °C between similarly sized wells</span></td>
<td align="center" valign="top"><span>± 0.1 °C between similarly sized wells</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b><span>Heating time</span></b></td>
<td style="text-align: center;" align="center" valign="top"><span>Ambient to 140 °C in 18 minutes</span></td>
<td style="text-align: center;" align="center" valign="top"><span>Ambient to 350 °C in 12 minutes</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b><span>Cooling Time</span></b></td>
<td align="center" valign="top"><span>Ambient to –25 °C in 20 minutes</span></td>
<td align="center" valign="top"><span>350 °C to 100 °C in 15 minutes</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b><span>Stability</span></b></td>
<td colspan="2" align="center" valign="top"><span>7 mins</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b><span>Immersion</span></b></td>
<td colspan="2" align="center" valign="top"><span>124 mm</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b><span>insert </span></b></td>
<td style="text-align: center;" colspan="2" align="center" valign="top"><span>Insert A, B, C, or D is included as standard (please specify when ordering). </span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b><span>Insert outer diameter</span></b></td>
<td colspan="2" align="center" valign="top"><span>31.8mm diameter x 124mm</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b><span>Interface </span></b></td>
<td style="text-align: center;" colspan="2" align="center" valign="top"><span>RS-232 interface</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b><span>power supply</span></b></td>
<td align="center" valign="top"><span>115 V ac (± 10 %), 1.3 A or 230 V ac (± 10 %), 0.7 A, switchable, 50/60 Hz, 150 W </span></td>
<td align="center" valign="top"><span>115 V ac (± 10 %), 4.4 A or 230 V ac (± 10 %), 2.2 A, switchable, 50/60 Hz, 500 W </span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b><span>Dimensions (WxHxD) </span></b></td>
<td style="text-align: center;" align="center" valign="top"><span>143 x 261 x 245 mm</span><br />
<span>(5.63 x 10.25 x 9.63 in) </span></td>
<td style="text-align: center;" align="center" valign="top"><span>152 x 86 x 197 mm</span><br />
<span>(6 x 3.375 x 7.75 in) </span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b><span>weight </span></b></td>
<td align="center" valign="top"><span>5.7 kg </span></td>
<td align="center" valign="top"><span>2.7 kg</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b><span>NIST traceable calibration</span></b></td>
<td align="center" valign="top"><span>Data points: –25 °C, 0 °C, 25 °C, 50 °C, 75 °C, 100 °C, and 140 ° </span></td>
<td align="center" valign="top"><span>Data points: 50 °C, 100 °C, 150 °C, 200 °C, 250 °C, 300 °C, and 350 °C </span></td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-9103-9140-field-drywell/">Fluke 9103/ 9140 Field Drywell</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 9009 Industrial Dual Block Calibrator</title>
		<link>https://koueitrading.com/global/product/fluke-9009-industrial-dual-block-calibrator/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 22 Oct 2020 04:47:54 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=127593</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 9009 Features A single unit covers a temperature range from –15 °C to 350 °C Comparison calibration can be performed simultaneously in two wells of each block Rugged, lightweight, waterproof case The 9009 Industrial Dual Block Calibrator can calibrate hot and cold simultaneously. Whether you think of it as doubling the [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-9009-industrial-dual-block-calibrator/">Fluke 9009 Industrial Dual Block Calibrator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 9009</p>
<h2 class="features-title">Features</h2>
<ul>
<li><span>A single unit covers a temperature range from –15 °C to 350 °C</span></li>
<li><span>Comparison calibration can be performed simultaneously in two wells of each block</span></li>
<li><span>Rugged, lightweight, waterproof case</span></li>
</ul>
<p><span>The 9009 Industrial Dual Block Calibrator can calibrate hot and cold simultaneously. Whether you think of it as doubling the number of calibrations you can perform or cutting your calibration time in half, it makes on-site temperature calibration easier than ever before.</span></p>
<h2>Specification</h2>
<table class="table" border="1" cellspacing="0" cellpadding="5">
<tbody>
<tr bgcolor="#e9eff4">
<td colspan="3"><span>specification</span></td>
</tr>
<tr>
<td valign="top"></td>
<td align="center" valign="top"><strong><span>High Temperature Block</span></strong></td>
<td align="center" valign="top"><strong><span>Cold Block</span></strong></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong><span>Temperature range</span></strong></td>
<td style="text-align: center;" align="center" valign="top"><span>50°C to 350°C</span></td>
<td style="text-align: center;" align="center" valign="top"><span>–15 °C to 110 °C (–8 °C when hot block is 350 °C)</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong><span>Accuracy</span></strong></td>
<td align="center" valign="top"><span>±0.6°C</span></td>
<td align="center" valign="top"><span>±0.2°C</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong><span>Stability</span></strong></td>
<td colspan="2" align="center" valign="top"><span>±0.05°C</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong><span>Well-to-well uniformity</span></strong></td>
<td colspan="2" align="center" valign="top"><span>±0.1°C</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong><span>Display resolution</span></strong></td>
<td style="text-align: center;" colspan="2" align="center" valign="top"><span>0.1°</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong><span>Heating time</span></strong></td>
<td align="center" valign="top"><span>30 minutes (heating from 25 °C to 350 °C)</span></td>
<td align="center" valign="top"><span>15 minutes (heating from 25 °C to 110 °C)</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong><span>Cooling Time</span></strong></td>
<td style="text-align: center;" align="center" valign="top"><span>40 minutes (cooling from 350 °C to 100 °C)</span></td>
<td style="text-align: center;" align="center" valign="top"><span>16 min (cooling from 25 °C to –15 °C)</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong><span>Stabilization Time</span></strong></td>
<td colspan="2" align="center" valign="top"><span>8 mins</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong><span>Well Depth</span></strong></td>
<td colspan="2" align="center" valign="top"><span>102 mm</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong><span>Removable inserts</span></strong></td>
<td colspan="2" align="center" valign="top"><span>Two 6.4 mm (1/4 in) and two 4.8 mm (3/16 in) inserts included standard; see &#8220;Product and Accessory Options&#8221; tab for additional inserts.</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong><span>Interface</span></strong></td>
<td style="text-align: center;" colspan="2" align="center" valign="top"><span>RS-232 interface</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong><span>power supply</span></strong></td>
<td colspan="2" align="center" valign="top"><span>115 V ac (± 10 %), 3 A, or 230 V ac (± 10 %), 2 A, specify, 50/60 Hz, 280 W</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong><span>Dimensions (HxWxD)</span></strong></td>
<td colspan="2" align="center" valign="top"><span>178 x 267 x 248 mm</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong><span>weight</span></strong></td>
<td colspan="2" align="center" valign="top"><span>4.5 kg</span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong><span>NIST traceable calibration</span></strong></td>
<td align="center" valign="top"><span>Calibration points: 50 °C, 100 °C, 150 °C, 200 °C, 250 °C, 300 °C, 350 °C</span></td>
<td align="center" valign="top"><span>Calibration points: –8 °C, 0 °C, 25 °C, 50 °C, 75 °C, 100 °C, 110 °C</span></td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-9009-industrial-dual-block-calibrator/">Fluke 9009 Industrial Dual Block Calibrator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 9100S/9102S Handheld Dry Well Calibrator</title>
		<link>https://koueitrading.com/global/product/fluke-9100s-9102s-handheld-dry-well-calibrator/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 22 Oct 2020 04:41:58 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=127587</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 9100S/9102S Features The world&#8217;s smallest, lightest, and most portable dry-well The world&#8217;s smallest dry well Temperature range: –10°C to 375°C Accuracy: ±0.25°C, Stability at 0°C: ±0.05°C RS-232 interface Specification specification 9100S 9102S Temperature range 35°C to 375°C –10 °C to 122 °C (at 23 °C ambient) Accuracy ± 0.25 °C at [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-9100s-9102s-handheld-dry-well-calibrator/">Fluke 9100S/9102S Handheld Dry Well Calibrator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 9100S/9102S</p>
<h2 class="features-title">Features</h2>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-127588 size-full" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-114405.png" alt="9100S/9102S" width="384" height="257" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-114405.png 384w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-114405-300x201.png 300w" sizes="auto, (max-width: 384px) 100vw, 384px" /></p>
<p>The world&#8217;s smallest, lightest, and most portable dry-well</p>
<ul>
<li>The world&#8217;s smallest dry well</li>
<li>Temperature range: –10°C to 375°C</li>
<li>Accuracy: ±0.25°C, Stability at 0°C: ±0.05°C</li>
<li>RS-232 interface</li>
</ul>
<h2><strong>Specification</strong></h2>
<table class="table" border="1" cellspacing="0" cellpadding="4">
<tbody>
<tr bgcolor="#e9eff4">
<td class="tableHead"><strong>specification</strong></td>
<td class="tableHead"><strong>9100S</strong></td>
<td class="tableHead"><strong>9102S</strong></td>
</tr>
<tr>
<td style="text-align: center;"><strong>Temperature range</strong></td>
<td style="text-align: center;">35°C to 375°C</td>
<td style="text-align: center;">–10 °C to 122 °C (at 23 °C ambient)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Accuracy</strong></td>
<td style="text-align: center;">± 0.25 °C at 50 °C; ± 0.25 °C at 100 °C; ± 0.5 °C at 375 °C</td>
<td style="text-align: center;">±0.25°C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Stability</strong></td>
<td style="text-align: center;">± 0.07 °C at 50 °C; ± 0.1 °C at 100 °C; ± 0.3 °C at 375 °C</td>
<td style="text-align: center;">±0.05°C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Well-to-well uniformity</strong></td>
<td style="text-align: center;" colspan="2">±0.2 °C at similar size sensors and same depths</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Heating time</strong></td>
<td style="text-align: center;">35°C to 375°C: 9.5 minutes</td>
<td style="text-align: center;">Ambient to 100 °C: 10 minutes</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Stabilization Time</strong></td>
<td style="text-align: center;">5 mins</td>
<td style="text-align: center;">7 mins</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Cooling Time</strong></td>
<td style="text-align: center;">375 °C to 100 °C: 14 min</td>
<td style="text-align: center;">Ambient to 0 °C: 10 minutes</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Well Depth</strong></td>
<td style="text-align: center;">102 mm; 89 mm for 1.6 mm diameter wells</td>
<td style="text-align: center;">102 mm</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Removable inserts</strong></td>
<td style="text-align: center;">none</td>
<td style="text-align: center;">1.6 mm (1/16 in) to 11.1 mm (7/16 in) [6.4 mm (1/4 in) and 4.8 mm (3/16 in) included standard]</td>
</tr>
<tr>
<td style="text-align: center;"><strong>power supply</strong></td>
<td style="text-align: center;">115Vac (± 10%), 55–65Hz, 1.5A<br />
or<br />
230 V ac (± 10 %), 0.8 A, 45–55 Hz<br />
175 W</td>
<td>
<p style="text-align: center;">94-234Vac (± 10%), 50/60Hz, 60W</p>
<p>&nbsp;</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Dimensions (HxWxD)</strong></td>
<td style="text-align: center;">57 x 125 x 150 mm</td>
<td style="text-align: center;">99 x 140 x 175 mm</td>
</tr>
<tr>
<td style="text-align: center;"><strong>weight</strong></td>
<td style="text-align: center;">1 kg</td>
<td style="text-align: center;">1.8 kg</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Interface</strong></td>
<td style="text-align: center;" colspan="2">RS-232 interface</td>
</tr>
<tr>
<td style="text-align: center;"><strong>NIST traceable calibration</strong></td>
<td style="text-align: center;">Data for 50 °C, 100 °C, 150 °C, 200 °C, 250 °C, 300 °C, 375 °C</td>
<td style="text-align: center;">Data for –10 °C, 0 °C, 25 °C, 50 °C, 75 °C, 100 °C, 122</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-9100s-9102s-handheld-dry-well-calibrator/">Fluke 9100S/9102S Handheld Dry Well Calibrator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 724 Temperature Calibrator</title>
		<link>https://koueitrading.com/global/product/fluke-724-temperature-calibrator/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 22 Oct 2020 04:31:41 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=127582</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 724 Features Heat is proud to present the new Fluke 724 Temperature Calibrator, a powerful, easy-to-use calibrator with measure and source capabilities to test and calibrate almost any thermometer. Easy-to-read dual display lets you check input and output simultaneously Measures RTDs, thermocouples, resistance, and voltage for testing sensors and transmitters Simulates [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-724-temperature-calibrator/">Fluke 724 Temperature Calibrator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 724</p>
<h2 class="features-title">Features</h2>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-127585 size-full" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-113816.png" alt="724" width="375" height="329" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-113816.png 375w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-22-113816-300x263.png 300w" sizes="auto, (max-width: 375px) 100vw, 375px" /></p>
<p><strong>Heat is proud to present</strong><br />
the new Fluke 724 Temperature Calibrator, a powerful, easy-to-use calibrator with measure and source capabilities to test and calibrate almost any thermometer.</p>
<ul>
<li>Easy-to-read dual display lets you check input and output simultaneously</li>
<li>Measures RTDs, thermocouples, resistance, and voltage for testing sensors and transmitters</li>
<li>Simulates or generates thermocouples, RTDs, voltages, and resistances for the purpose of calibrating transmitters</li>
<li>Performs fast linear tests with 25% and 100% steps</li>
<li>Runs remote tests with auto-step and auto-ramp</li>
<li>Loop supply with simultaneous current measurement is used to power the transmitter during testing</li>
<li>Compact, streamlined design makes it easy to carry</li>
<li>Rugged and reliable design for outdoor use</li>
<li>Backlight allows you to work even in dimly lit areas</li>
<li>Large battery capacity with 4 AA batteries</li>
<li>Easy-to-replace battery case cover</li>
</ul>
<h2>Specifications:</h2>
<div id="fluke-product-display-specs">
<div id="product-specs">
<div id="specification_content">
<table class="dataframe" border="1">
<thead>
<tr style="text-align: right;">
<th>Measurement Type</th>
<th>Range</th>
<th>Accuracy</th>
</tr>
</thead>
<tbody>
<tr>
<td style="text-align: center;">DC voltage</td>
<td style="text-align: center;">30.000 V</td>
<td style="text-align: center;">0.02 % + 2 counts (upper display)</td>
</tr>
<tr>
<td style="text-align: center;">DC voltage</td>
<td style="text-align: center;">20.000 V</td>
<td style="text-align: center;">0.02 % + 2 counts (lower display)</td>
</tr>
<tr>
<td style="text-align: center;">DC voltage</td>
<td style="text-align: center;">100.00 mV</td>
<td style="text-align: center;">0.02% + 2 counts</td>
</tr>
<tr>
<td style="text-align: center;">DC voltage</td>
<td style="text-align: center;">-10.00mV to 75.00mV</td>
<td style="text-align: center;">0.025 % + 1 count (through TC connector)</td>
</tr>
<tr>
<td style="text-align: center;">DC Current</td>
<td style="text-align: center;">24.000mA</td>
<td style="text-align: center;">0.02% + 2 counts</td>
</tr>
<tr>
<td style="text-align: center;">Resistance</td>
<td style="text-align: center;">0.0 to 400.0 Ω</td>
<td style="text-align: center;">0.1 Ω (4-wire), 0.15 Ω (2-wire and 3-wire)</td>
</tr>
<tr>
<td style="text-align: center;">Resistance</td>
<td style="text-align: center;">401 to 1500 ohms</td>
<td style="text-align: center;">0.5 Ω (4-wire), 1 Ω (2-wire and 3-wire)</td>
</tr>
<tr>
<td style="text-align: center;">Resistance</td>
<td style="text-align: center;">1500 to 3200 ohms</td>
<td style="text-align: center;">1 Ω (4-wire), 1.5 Ω (2-wire and 3-wire)</td>
</tr>
<tr>
<td style="text-align: center;">DC voltage</td>
<td style="text-align: center;">100.00 mV</td>
<td style="text-align: center;">0.02% + 2 counts</td>
</tr>
<tr>
<td style="text-align: center;">DC voltage</td>
<td style="text-align: center;">10.000 V</td>
<td style="text-align: center;">0.02% + 2 counts</td>
</tr>
<tr>
<td style="text-align: center;">DC voltage</td>
<td style="text-align: center;">-10.00mV to 75.00mV</td>
<td style="text-align: center;">0.025 % + 1 count (through TC connector)</td>
</tr>
<tr>
<td style="text-align: center;">Resistance</td>
<td style="text-align: center;">15.0 to 400.0 Ω</td>
<td style="text-align: center;">0.15 Ω (excitation current 0.15 to 0.5 mA), 0.1 Ω (excitation current 0.5 to 2 mA)</td>
</tr>
<tr>
<td style="text-align: center;">Resistance</td>
<td style="text-align: center;">401 to 1500 ohms</td>
<td style="text-align: center;">0.5 Ω (excitation current 0.05 to 0.8 mA)</td>
</tr>
<tr>
<td style="text-align: center;">Resistance</td>
<td style="text-align: center;">1500 to 3200 ohms</td>
<td style="text-align: center;">1 Ω (excitation current 0.05 to 0.4 mA)</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>The post <a href="https://koueitrading.com/global/product/fluke-724-temperature-calibrator/">Fluke 724 Temperature Calibrator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 714B Thermocouple Calibrator</title>
		<link>https://koueitrading.com/global/product/fluke-714b-thermocouple-calibrator/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Wed, 07 Oct 2020 01:53:09 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125935</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 714B Features The 714B can measure and simulate 17 different thermocouples and mV Measures 4 to 20 mA signals and simultaneously emits a temperature signal Magnetic hangers designed to fit each device are included as standard. Configurable 0% and 100% source settings for quick checking of 25% linearity Linear ramp and [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-714b-thermocouple-calibrator/">Fluke 714B Thermocouple Calibrator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 714B</p>
<h2 class="features-title">Features</h2>
<div id="keyfeature_content" data-readmore="" aria-expanded="true">
<ul>
<li>The 714B can measure and simulate 17 different thermocouples and mV</li>
<li>Measures 4 to 20 mA signals and simultaneously emits a temperature signal</li>
<li>Magnetic hangers designed to fit each device are included as standard.</li>
<li>Configurable 0% and 100% source settings for quick checking of 25% linearity</li>
<li>Linear ramp and 25% step auto ramp based on 0% and 100% settings</li>
<li>Dual input and backlit display for easy reading of measurements</li>
<li>Settings from when the power was turned off are remembered when the power is turned on, making it easy to resume testing</li>
<li>1 year/2 year specifications and traceable calibration certificate</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-125938" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-07-085649.png" alt="714B" width="426" height="294" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-07-085649.png 577w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-07-085649-300x207.png 300w" sizes="auto, (max-width: 426px) 100vw, 426px" /></p>
<h2>Specifications</h2>
<div id="fluke-product-display-specs">
<div id="product-specs">
<div id="specification_content">
<table class="border-one" width="100%">
<tbody>
<tr>
<td class="bodybold" style="text-align: center;" colspan="2">General Specifications</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Maximum voltage applied between any terminal and ground, or between any two terminals</td>
<td style="text-align: center;">30V</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Operating temperature</td>
<td style="text-align: center;">-10°C to 50°C</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Storage temperature</td>
<td style="text-align: center;">-30°C to 60°C</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Operating altitude</td>
<td style="text-align: center;">2,000m</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Storage altitude</td>
<td style="text-align: center;">12,000 m</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;" rowspan="5">Relative Humidity (% RH, non-condensing)</td>
<td style="text-align: center;">No condensation</td>
</tr>
<tr>
<td style="text-align: center;">90% (10°C to 30°C)</td>
</tr>
<tr>
<td style="text-align: center;">75% (30°C to 40°C)</td>
</tr>
<tr>
<td style="text-align: center;">45% (40°C to 50°C)</td>
</tr>
<tr>
<td style="text-align: center;">(No condensation)</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">vibration</td>
<td style="text-align: center;">MIL-T-28800E, Class 2</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Drop Test</td>
<td style="text-align: center;">1 m</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">IP Rating</td>
<td style="text-align: center;">IEC 60529: IP52</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Electromagnetic environment</td>
<td style="text-align: center;">IEC 61326-1, portable</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Safety</td>
<td style="text-align: center;">IEC 61010-1, 30 V max (to earth), Pollution Degree 2</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">power supply</td>
<td style="text-align: center;">4 AA batteries (NEDA 1.5A, IEC LR6)</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Dimensions (H x W x L)</td>
<td style="text-align: center;">52.5mm x 84mm x 188.5mm</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">weight</td>
<td style="text-align: center;">515 g</td>
</tr>
</tbody>
</table>
<table class="border-one" width="100%">
<tbody>
<tr>
<td class="bodybold" style="text-align: center;" colspan="2">DC mA measurement</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">resolution</td>
<td style="text-align: center;">0 to 24mA</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">range</td>
<td style="text-align: center;">0.001mA</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Accuracy (% of reading + counts)</td>
<td style="text-align: center;">0.010% + 2 μA</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Temperature coefficient</td>
<td style="text-align: center;">±(0.002% of reading + 0.002% of range)/°C (&lt;18°C, or &gt;28°C)</td>
</tr>
</tbody>
</table>
<table class="border-one" width="100%">
<tbody>
<tr>
<td class="bodybold" style="text-align: center;" colspan="2">Millivolt Measurement and Source</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">resolution</td>
<td style="text-align: center;">-10mV to 75mV</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">range</td>
<td style="text-align: center;">0.01mV</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Accuracy (% of reading + counts)</td>
<td style="text-align: center;">0.015% + 10 μA</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Temperature coefficient</td>
<td style="text-align: center;">±(0.002% of reading + 0.002% of range)/°C (&lt;18°C, or &gt;28°C)</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>The post <a href="https://koueitrading.com/global/product/fluke-714b-thermocouple-calibrator/">Fluke 714B Thermocouple Calibrator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 712B RTD Calibrator</title>
		<link>https://koueitrading.com/global/product/fluke-712b-rtd-calibrator/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Wed, 07 Oct 2020 01:43:23 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125929</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 712B Features The 712B can measure and simulate 13 different types of RTDs and resistances Measures 4 to 20 mA signals and simultaneously emits a temperature signal Magnetic hangers designed to fit each device are included as standard. Configurable 0% and 100% source settings for quick checking of 25% linearity Linear [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-712b-rtd-calibrator/">Fluke 712B RTD Calibrator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 712B</p>
<h2>Features</h2>
<div id="keyfeature_content" data-readmore="" aria-expanded="true">
<ul>
<li>The 712B can measure and simulate 13 different types of RTDs and resistances</li>
<li>Measures 4 to 20 mA signals and simultaneously emits a temperature signal</li>
<li>Magnetic hangers designed to fit each device are included as standard.</li>
<li>Configurable 0% and 100% source settings for quick checking of 25% linearity</li>
<li>Linear ramp and 25% step auto ramp based on 0% and 100% settings</li>
<li>Dual input and backlit display for easy reading of measurements</li>
<li>Settings from when the power was turned off are remembered when the power is turned on, making it easy to resume testing</li>
<li>1 year/2 year specifications and traceable calibration certificate</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-125930" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-07-084713.png" alt="712B" width="404" height="273" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-07-084713.png 580w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-07-084713-300x203.png 300w" sizes="auto, (max-width: 404px) 100vw, 404px" /></p>
<h2>Specifications</h2>
<div id="fluke-product-display-specs">
<div id="product-specs">
<div id="specification_content">
<div class="clickability">
<table>
<tbody>
<tr>
<th>General Specifications</th>
<th></th>
</tr>
<tr>
<td style="text-align: center;">Maximum voltage applied between any terminal and ground, or between any two terminals</td>
<td style="text-align: center;">30V</td>
</tr>
<tr>
<td style="text-align: center;">Operating temperature</td>
<td style="text-align: center;">-10°C to 50°C</td>
</tr>
<tr>
<td style="text-align: center;">Storage temperature</td>
<td style="text-align: center;">-30°C to 60°C</td>
</tr>
<tr>
<td style="text-align: center;">Operating altitude</td>
<td style="text-align: center;">2,000m</td>
</tr>
<tr>
<td style="text-align: center;">Storage altitude</td>
<td style="text-align: center;">12,000 m</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="5">Relative Humidity (% RH, non-condensing)</td>
<td style="text-align: center;">No condensation</td>
</tr>
<tr>
<td style="text-align: center;">90% (10°C to 30°C)</td>
</tr>
<tr>
<td style="text-align: center;">75% (30°C to 40°C)</td>
</tr>
<tr>
<td style="text-align: center;">45% (40°C to 50°C)</td>
</tr>
<tr>
<td style="text-align: center;">(No condensation)</td>
</tr>
<tr>
<td style="text-align: center;">Vibration</td>
<td style="text-align: center;">MIL-T-28800E, Class 2</td>
</tr>
<tr>
<td style="text-align: center;">Drop Test</td>
<td style="text-align: center;">1 m</td>
</tr>
<tr>
<td style="text-align: center;">IP Rating</td>
<td style="text-align: center;">IEC 60529: IP52</td>
</tr>
<tr>
<td style="text-align: center;">Electromagnetic environment</td>
<td style="text-align: center;">IEC 61326-1, portable</td>
</tr>
<tr>
<td style="text-align: center;">Safety</td>
<td style="text-align: center;">IEC 61010-1, 30 V max (to earth), Pollution Degree 2</td>
</tr>
<tr>
<td style="text-align: center;">Power supply</td>
<td style="text-align: center;">4 AA batteries (NEDA 1.5A, IEC LR6)</td>
</tr>
<tr>
<td style="text-align: center;">Dimensions (H x W x L)</td>
<td style="text-align: center;">52.5mm x 84mm x 188.5mm</td>
</tr>
<tr>
<td style="text-align: center;">Weight</td>
<td style="text-align: center;">515 g</td>
</tr>
</tbody>
</table>
<h2>DC mA Measurement</h2>
<table>
<tbody>
<tr>
<td style="text-align: center;">Resolution</td>
<td style="text-align: center;">0 to 24mA</td>
</tr>
<tr>
<td style="text-align: center;">Range</td>
<td style="text-align: center;">0.001mA</td>
</tr>
<tr>
<td style="text-align: center;">Accuracy (% of reading + counts)</td>
<td style="text-align: center;">0.010% + 2 μA</td>
</tr>
<tr>
<td style="text-align: center;">Temperature coefficient</td>
<td style="text-align: center;">±(0.002% of reading + 0.002% of range)/°C (&lt;18°C, or &gt;28°C)</td>
</tr>
</tbody>
</table>
<h2>Resistance Measurement</h2>
<table>
<tbody>
<tr>
<td style="text-align: center;">Resistance Range</td>
<td style="text-align: center;">Accuracy (% of reading + counts)</td>
</tr>
<tr>
<td style="text-align: center;">0.00 Ω to 400.00 Ω</td>
<td style="text-align: center;">0.015% + 0.05 Ω</td>
</tr>
<tr>
<td style="text-align: center;">400.0 Ω to 4000.0 Ω</td>
<td style="text-align: center;">0.015% + 0.5 Ω</td>
</tr>
<tr>
<td style="text-align: center;" colspan="2">Note: Reading accuracy is based on 4-wire input. For 3-wire resistance measurements, assume all 3 leads are matched, add 0.05 Ω (0.00 Ω to 400.00 Ω), 0.2 Ω (400.0 Ω to 4000.0 Ω) to spec.</td>
</tr>
<tr>
<td style="text-align: center;">Temperature coefficient</td>
<td style="text-align: center;">±(0.002% of reading + 0.002% of range)/°C (&lt;18°C, or &gt;28°C)</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<div></div>
</div>
</div>
</div>
</div>
</div>The post <a href="https://koueitrading.com/global/product/fluke-712b-rtd-calibrator/">Fluke 712B RTD Calibrator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 9132/9133 Portable Radiation Thermometer Calibrator</title>
		<link>https://koueitrading.com/global/product/fluke-9132-9133-portable-radiation-thermometer-calibrator/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Wed, 07 Oct 2020 01:14:50 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125915</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 9132/9133 Features Infrared thermometer verification –30 °C to 500 °C) 57 mm large blackbody target A well for a reference resistance thermometer is provided, allowing contact type measurements Small and lightweight Specification Specification 9133 9132 Temperature range –30 °C to 150 °C (ambient temperature 23 °C) 50°C to 500°C Accuracy ±0.4°C [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-9132-9133-portable-radiation-thermometer-calibrator/">Fluke 9132/9133 Portable Radiation Thermometer Calibrator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 9132/9133</p>
<h2>Features</h2>
<ul>
<li>Infrared thermometer verification –30 °C to 500 °C)</li>
<li>57 mm large blackbody target</li>
<li>A well for a reference resistance thermometer is provided, allowing contact type measurements</li>
<li>Small and lightweight</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-125924 size-full" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-07-083548.png" alt="9132/9133" width="266" height="239" /></p>
<h2>Specification</h2>
<table class="table" border="1" cellspacing="0" cellpadding="4">
<tbody>
<tr bgcolor="#e9eff4">
<td class="tableHead" style="text-align: center;">Specification</td>
<td class="tableHead" style="text-align: center;"><strong>9133</strong></td>
<td class="tableHead" style="text-align: center;"><strong>9132</strong></td>
</tr>
<tr>
<td style="text-align: center;">Temperature range</td>
<td style="text-align: center;">–30 °C to 150 °C (ambient temperature 23 °C)</td>
<td style="text-align: center;">50°C to 500°C</td>
</tr>
<tr>
<td style="text-align: center;">Accuracy</td>
<td style="text-align: center;">±0.4°C</td>
<td style="text-align: center;">± 0.5 °C at 100 °C<br />
± 0.8 °C at 500 °C</td>
</tr>
<tr>
<td style="text-align: center;">Stability</td>
<td style="text-align: center;">±0.1°C</td>
<td style="text-align: center;">± 0.1°C at 100°C<br />
± 0.3°C at 500°C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Target Size</strong></td>
<td style="text-align: center;" colspan="2">57 mm</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Target emissivity</strong></td>
<td style="text-align: center;" colspan="2">0.95 (± 0.02 in the wavelength range 8 to 14 µm)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>resolution</strong></td>
<td style="text-align: center;" colspan="2">0.1°</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Heating time</strong></td>
<td style="text-align: center;">15 minutes (25 °C to 150 °C)</td>
<td style="text-align: center;">30 minutes (50 °C to 500 °C)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Cooling Time</strong></td>
<td style="text-align: center;">15 min (25 °C to –20 °C)</td>
<td style="text-align: center;">30 minutes (500 °C to 100 °C)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Interface</strong></td>
<td style="text-align: center;" colspan="2">RS-232 interface</td>
</tr>
<tr>
<td style="text-align: center;">power supply</td>
<td style="text-align: center;">115 V ac (± 10%), 1.5 A, or<br />
230 V ac (± 10%), 1.0 A,<br />
switchable, 50/60 Hz, 200 W</td>
<td style="text-align: center;">115 V ac (± 10 %), 3 A or<br />
230 V ac (± 10 %), 1.5 A,<br />
switchable, 50/60 Hz, 340 W</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Dimensions (HxWxD)<br />
</strong></td>
<td style="text-align: center;">152 x 286 x 267 mm</td>
<td style="text-align: center;">102 x 152 x 178 mm</td>
</tr>
<tr>
<td style="text-align: center;"><strong>weight</strong></td>
<td style="text-align: center;">4.6 kg</td>
<td style="text-align: center;">1.8 kg</td>
</tr>
<tr>
<td style="text-align: center;"><strong>NIST-traceable contact calibration</strong></td>
<td style="text-align: center;">Data points: –30°C, 0°C, 25°C, 75°C, 100°C, 125°C, 150°C</td>
<td style="text-align: center;">Data points: 50°C, 100°C, 200°C, 250°C, 300°C, 400°C, 500°C</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-9132-9133-portable-radiation-thermometer-calibrator/">Fluke 9132/9133 Portable Radiation Thermometer Calibrator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 6109A / 7109A Portable Calibration Baths</title>
		<link>https://koueitrading.com/global/product/fluke-6109a-7109a-portable-calibration-baths/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 03 Oct 2020 08:08:33 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125694</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 6109A / 7109A Features Calibrate up to four tri-clamp sanitary sensors per batch with ± 0.1 °C temperature display accuracy. Covers a wide temperature range: 6109A: 35 °C to 250 °C 7109A: -25 °C to 140 °C. Stainless steel casing that withstands harsh cleaning solutions; it&#8217;s easy to transport and maintain. [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-6109a-7109a-portable-calibration-baths/">Fluke 6109A / 7109A Portable Calibration Baths</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 6109A / 7109A</p>
<h2 class="features-title">Features</h2>
<div id="keyfeature_content">
<ul>
<li>Calibrate up to four tri-clamp sanitary sensors per batch with ± 0.1 °C temperature display accuracy.</li>
<li>Covers a wide temperature range: 6109A: 35 °C to 250 °C</li>
<li>7109A: -25 °C to 140 °C.</li>
<li>Stainless steel casing that withstands harsh cleaning solutions; it&#8217;s easy to transport and maintain.</li>
</ul>
<p><img loading="lazy" decoding="async" class="alignleft wp-image-125696" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-151348.png" alt="6109A / 7109A" width="306" height="242" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-151348.png 502w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-151348-300x237.png 300w" sizes="auto, (max-width: 306px) 100vw, 306px" /> <img loading="lazy" decoding="async" class="wp-image-125697 alignleft" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-151341.png" alt="" width="365" height="256" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-151341.png 575w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-151341-300x211.png 300w" sizes="auto, (max-width: 365px) 100vw, 365px" /></p>
<h2><strong>Specifications</strong></h2>
<table>
<tbody>
<tr>
<th>Specification</th>
<th>Details</th>
</tr>
<tr>
<td style="text-align: center;">Size</td>
<td style="text-align: center;">Height: 382 mm (15 in)<br />
Width: 242 mm (9.5 in)<br />
Depth: 400 mm (15.7 in)</td>
</tr>
<tr>
<td style="text-align: center;">Weight</td>
<td style="text-align: center;">6109A: 16 kg (35 lb)<br />
7109A: 20 kg (44 lb)</td>
</tr>
<tr>
<td style="text-align: center;">Fluid volume</td>
<td style="text-align: center;">2.5 liters (0.66 gallons)</td>
</tr>
<tr>
<td style="text-align: center;">Fluid working area</td>
<td style="text-align: center;">75 mm x 75 mm (3 in x 3 in)</td>
</tr>
<tr>
<td style="text-align: center;">Maximum fluid depth</td>
<td style="text-align: center;">154 mm (6.1 in)</td>
</tr>
<tr>
<td style="text-align: center;">Factory calibration</td>
<td style="text-align: center;">Traceable NVLAP-accredited calibration included</td>
</tr>
</tbody>
</table>
<h3>Temperature Specifications</h3>
<p>The temperature specifications describe the Absolute Instrumental Uncertainty at 95% level of confidence (coverage factor k = 2) within one year from calibration. The specifications include environmental temperature effects from 13 °C to 33 °C.</p>
<table>
<tbody>
<tr>
<th>Specification</th>
<th>6109A</th>
<th>7109A</th>
</tr>
<tr>
<td style="text-align: center;">Range (at 25 °C ambient temperature)</td>
<td style="text-align: center;">35 °C to 250 °C</td>
<td style="text-align: center;">–25 °C to 140 °C (–15 °C cover off)</td>
</tr>
<tr>
<td style="text-align: center;">Accuracy (maximum permissible error)</td>
<td style="text-align: center;">0.1 °C</td>
<td style="text-align: center;">0.1 °C</td>
</tr>
<tr>
<td style="text-align: center;">Display resolution</td>
<td style="text-align: center;">0.01 °, 0.001°</td>
<td style="text-align: center;">0.01 °, 0.001°</td>
</tr>
<tr>
<td style="text-align: center;">Stability</td>
<td style="text-align: center;">0.015 °C</td>
<td style="text-align: center;">0.01 °C</td>
</tr>
<tr>
<td style="text-align: center;">Typical uniformity</td>
<td style="text-align: center;">0.03 °C up to 200 °C<br />
0.04 °C above 200 °C</td>
<td style="text-align: center;">0.02 °C</td>
</tr>
<tr>
<td style="text-align: center;">Repeatability</td>
<td style="text-align: center;">0.04 °C</td>
<td style="text-align: center;">0.04 °C</td>
</tr>
<tr>
<td style="text-align: center;">Typical heating time</td>
<td style="text-align: center;">35 °C to 100 °C: 25 minutes<br />
100 °C to 250 °C: 45 minutes</td>
<td style="text-align: center;">–25 °C to 25 °C: 35 minutes<br />
25 °C to 140 °C: 55 minutes</td>
</tr>
<tr>
<td style="text-align: center;">Typical cooling time</td>
<td style="text-align: center;">250 °C to 100 °C: 35 minutes<br />
100 °C to 35 °C: 55 minutes</td>
<td style="text-align: center;">140 °C to 25 °C: 45 minutes<br />
25 °C to –25 °C: 75 minutes</td>
</tr>
<tr>
<td style="text-align: center;">Typical settling time</td>
<td style="text-align: center;">15 minutes</td>
<td style="text-align: center;">10 minutes</td>
</tr>
</tbody>
</table>
<h3 data-pm-slice="0 0 []">Process Input Module specifications (-P models)</h3>
<p>The Input Module specifications describe the Absolute Instrumental Uncertainty at 95% level of confidence (coverage factor k = 2) within one year from calibration. The specifications include calibration uncertainty, linearity, repeatability, resolution, stability, and environmental temperature effects from 13 °C to 33 °C.</p>
<table>
<tbody>
<tr>
<th>Function</th>
<th>Range</th>
<th>Accuracy (Maximum Permissible Error)</th>
</tr>
<tr>
<td style="text-align: center;">Reference input resistance</td>
<td style="text-align: center;">0 Ω to 42 Ω<br />
42 Ω to 400 Ω</td>
<td style="text-align: center;">0.0025 Ω<br />
0.006%</td>
</tr>
<tr>
<td style="text-align: center;">Reference input temperature</td>
<td style="text-align: center;">–25 °C to 250 °C</td>
<td style="text-align: center;">0.007% + 0.015 °C</td>
</tr>
<tr>
<td style="text-align: center;">Resistance sensing current</td>
<td style="text-align: center;">1 mA</td>
<td style="text-align: center;">8%</td>
</tr>
<tr>
<td style="text-align: center;">DUT 4-wire resistance</td>
<td style="text-align: center;">0 Ω to 31 Ω<br />
31 Ω to 400 Ω</td>
<td style="text-align: center;">0.0025 Ω<br />
0.008%</td>
</tr>
<tr>
<td style="text-align: center;">DUT 3-wire resistance accuracy</td>
<td style="text-align: center;">0 Ω to 400 Ω</td>
<td style="text-align: center;">0.12 Ω</td>
</tr>
<tr>
<td style="text-align: center;">Thermocouple mV</td>
<td style="text-align: center;">–10 mV to 100 mV</td>
<td style="text-align: center;">0.025% + 0.01 mV</td>
</tr>
<tr>
<td style="text-align: center;">Reference junction temperature</td>
<td style="text-align: center;">0 °C to 40 °C</td>
<td style="text-align: center;">0.35 °C</td>
</tr>
<tr>
<td style="text-align: center;">Thermocouple temperature</td>
<td style="text-align: center;">–25 °C to 250 °C<br />
0 °C to 250 °C</td>
<td style="text-align: center;">J: 0.44 °C<br />
E: 0.44 °C<br />
L: 0.42 °C<br />
K: 0.49 °C<br />
N: 0.57 °C<br />
U: 0.48 °C<br />
T: 0.53 °C<br />
M: 0.48 °C<br />
R: 1.92 °C<br />
D: 1.12 °C<br />
S: 1.88 °C<br />
G/W: 3.34 °C<br />
C: 0.84 °C</td>
</tr>
<tr>
<td style="text-align: center;">mA range</td>
<td style="text-align: center;">0 mA to 22 mA</td>
<td style="text-align: center;">0.02% + 0.002 mA</td>
</tr>
<tr>
<td style="text-align: center;">Loop power</td>
<td style="text-align: center;">24 V dc</td>
<td style="text-align: center;">± 6 V</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
</div>The post <a href="https://koueitrading.com/global/product/fluke-6109a-7109a-portable-calibration-baths/">Fluke 6109A / 7109A Portable Calibration Baths</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 6102/ 7102/ 7103 Micro-Bath Thermometer Calibrators</title>
		<link>https://koueitrading.com/global/product/fluke-6102-7102-7103-micro-bath-thermometer-calibrators/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 03 Oct 2020 08:01:04 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125686</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 6102/ 7102/ 7103 Features World’s smallest portable calibration baths Calibrates sensors of any size or shape Stability to ±0.015 °C Ranges from –30 °C to 200 °C Specifications 6102  7102  7103  Range  35 °C to 200 °C (95 °F to 392 °F) –5 °C to 125 °C (23 °F to 257 °F) –30 °C to 125 °C (–22 °F to 257 °F) Accuracy  [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-6102-7102-7103-micro-bath-thermometer-calibrators/">Fluke 6102/ 7102/ 7103 Micro-Bath Thermometer Calibrators</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 6102/ 7102/ 7103</p>
<h2>Features</h2>
<ul>
<li>World’s smallest portable calibration baths</li>
<li>Calibrates sensors of any size or shape</li>
<li>Stability to ±0.015 °C</li>
<li>Ranges from –30 °C to 200 °C</li>
</ul>
<p><img loading="lazy" decoding="async" class="alignleft wp-image-125688" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-150443.png" alt="6102/ 7102/ 7103" width="211" height="307" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-150443.png 371w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-150443-206x300.png 206w" sizes="auto, (max-width: 211px) 100vw, 211px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-125689" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-150424.png" alt="6102/ 7102/ 7103" width="251" height="287" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-150424.png 499w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-150424-262x300.png 262w" sizes="auto, (max-width: 251px) 100vw, 251px" /></p>
<h2>Specifications</h2>
<table class="table" border="1" cellspacing="0" cellpadding="5">
<tbody>
<tr valign="top" bgcolor="#e9eff4">
<td valign="top"></td>
<td align="center" valign="top"><b>6102 </b></td>
<td align="center" valign="top"><b>7102 </b></td>
<td align="center" valign="top"><b>7103 </b></td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><b>Range </b></td>
<td align="center" valign="top">35 °C to 200 °C<br />
(95 °F to 392 °F)</td>
<td align="center" valign="top">–5 °C to 125 °C<br />
(23 °F to 257 °F)</td>
<td align="center" valign="top">–30 °C to 125 °C<br />
(–22 °F to 257 °F)</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><b>Accuracy </b></td>
<td colspan="3" align="center" valign="top">± 0.25 °C</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><b>Stability </b></td>
<td align="center" valign="top">± 0.02 °C at 100 °C<br />
(oil 5013)<br />
± 0.03 °C at 200 °C<br />
(oil 5013)</td>
<td align="center" valign="top">± 0.015 °C at –5 °C<br />
(oil 5010)<br />
± 0.03 °C at 121 °C<br />
(oil 5010)</td>
<td align="center" valign="top">± 0.03 °C at –25 °C<br />
(oil 5010)<br />
± 0.05 °C at 125 °C<br />
(oil 5010)</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><b>Uniformity </b></td>
<td colspan="3" align="center" valign="top">± 0.02 °C</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><b>Resolution </b></td>
<td colspan="3" align="center" valign="top">0.01 °C/°F</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><b>Operating Temperature </b></td>
<td colspan="3" align="center" valign="top">5 °C to 45 °C</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><b>Heating Time </b></td>
<td align="center" valign="top">25 °C to 200 °C:<br />
40 minutes</td>
<td align="center" valign="top">25 °C to 100 °C:<br />
30 minutes</td>
<td align="center" valign="top">25 °C to 100 °C:<br />
35 minutes</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><b>Cooling Time </b></td>
<td align="center" valign="top">200 °C to 100 °C:<br />
35 minutes</td>
<td align="center" valign="top">25 °C to 0 °C:<br />
30 minutes</td>
<td align="center" valign="top">25 °C to –25 °C:<br />
45 minutes</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><b>Well Size </b></td>
<td colspan="3" align="center" valign="top">64 mm dia. x 140 mm deep (2.5 x 5.5 in) (working area is 48 mm [1.9 in] in diameter)</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><b>Size (WxHxD) </b></td>
<td align="center" valign="top">14 x 26 x 20 cm<br />
(5.5 x 10.38 x 8 in)</td>
<td align="center" valign="top">18 x 31 x 24 cm<br />
(7.2 x 12 x 9.5 in)</td>
<td align="center" valign="top">23 x 34 x 26 cm<br />
(9 x 13.2 x 10.5 in)</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><b>Weight </b></td>
<td align="center" valign="top">4.5 kg (10 lb) with fluid</td>
<td align="center" valign="top">6.8 kg (15 lb) with fluid</td>
<td align="center" valign="top">9.8 kg (22 lb) with fluid</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><b>Volume </b></td>
<td align="center" valign="top">0.75 L (1.6 pints)</td>
<td align="center" valign="top">0.75 L (1.6 pints)</td>
<td align="center" valign="top">1.0 L (2.11 pints)</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><b>Power </b></td>
<td align="center" valign="top">115 V ac (± 10 %), 2.3 A or 230 V ac (± 10 %), 1.1 A, switchable, 50/60 Hz,<br />
270 W</td>
<td align="center" valign="top">115 V ac (± 10 %), 1.8 A or 230 V ac (± 10 %), 0.9 A, switchable, 50/60 Hz,<br />
200 W</td>
<td align="center" valign="top">94–234 V ac (± 10 %), 50/60 Hz, 400 W</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><b>Computer Interface </b></td>
<td colspan="3" align="center" valign="top">RS-232 interface</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><b>NIST-Traceable Calibration </b></td>
<td align="center" valign="top">Data at 50 °C, 100 °C, 150 °C, and 200 °C</td>
<td align="center" valign="top">Data at –5 °C, 25 °C, 55 °C, 90 °C, and 121 °C</td>
<td align="center" valign="top">Data at –25 °C, 0 °C, 25 °C, 50 °C, 75 °C, 100 °C, and 125 °C</td>
</tr>
<tr valign="top">
<td style="text-align: center;" rowspan="3" valign="top"><b><strong>Commonly Used Fluids<sup>1</sup></strong> </b></td>
<td align="center" valign="top">Water (distilled)</td>
<td align="center" valign="top">Do <u>not</u> use Water <sup>2</sup></td>
<td align="center" valign="top">Water (distilled)</td>
</tr>
<tr valign="top">
<td align="center" valign="top">Mineral Oil</td>
<td align="center" valign="top">Mineral Oil</td>
<td align="center" valign="top">Mineral Oil</td>
</tr>
<tr valign="top">
<td align="center" valign="top">Silicone Oil</td>
<td align="center" valign="top">Silicone Oil</td>
<td align="center" valign="top">Silicone Oil</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table class="table" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="99%"><sup>1</sup> Refer to the Users Guide for information on selecting the right bath fluid for your application.</td>
</tr>
<tr>
<td><sup>2</sup> If the 7102 tank coating is damaged, corrosion will occur due to dissimilar metals in contact with water.</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-6102-7102-7103-micro-bath-thermometer-calibrators/">Fluke 6102/ 7102/ 7103 Micro-Bath Thermometer Calibrators</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 9190A Ultra-Cool Field Metrology Well</title>
		<link>https://koueitrading.com/global/product/fluke-9190a-ultra-cool-field-metrology-well/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 03 Oct 2020 07:47:39 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125677</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 9190A Features Wide temperature range: –95 °C to 140 °C. Excellent accuracy Accuracy using built-in reference thermometer readout: ± 0.05 °C full range. Display accuracy: ± 0.2 °C full range. Best-in-class stability: ± 0.015 °C full range Specifications Specification Details Temperature range at 23°C –95°C to 140°C (–139°F to 284°F) Display [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-9190a-ultra-cool-field-metrology-well/">Fluke 9190A Ultra-Cool Field Metrology Well</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 9190A</p>
<h2 class="features-title">Features</h2>
<div id="keyfeature_content">
<ul>
<li>Wide temperature range: –95 °C to 140 °C.</li>
<li>Excellent accuracy</li>
<li>Accuracy using built-in reference thermometer readout: ± 0.05 °C full range.</li>
<li>Display accuracy: ± 0.2 °C full range.</li>
<li>Best-in-class stability: ± 0.015 °C full range</li>
</ul>
<p><img loading="lazy" decoding="async" class="alignleft wp-image-125683" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-145617.png" alt="9190A" width="307" height="212" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-145617.png 563w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-145617-300x207.png 300w" sizes="auto, (max-width: 307px) 100vw, 307px" /> <img loading="lazy" decoding="async" class="wp-image-125684 alignleft" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-145603.png" alt="" width="260" height="288" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-145603.png 318w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-145603-271x300.png 271w" sizes="auto, (max-width: 260px) 100vw, 260px" /></p>
<h2>Specifications</h2>
<div id="fluke-product-display-specs">
<div id="product-specs">
<div id="specification_content">
<div class="clickability">
<table>
<tbody>
<tr>
<th>Specification</th>
<th>Details</th>
</tr>
<tr>
<td style="text-align: center;">Temperature range at 23°C</td>
<td style="text-align: center;">–95°C to 140°C (–139°F to 284°F)</td>
</tr>
<tr>
<td style="text-align: center;">Display accuracy</td>
<td style="text-align: center;">±0.2°C full range</td>
</tr>
<tr>
<td style="text-align: center;">Accuracy with external reference<sup>3</sup></td>
<td style="text-align: center;">±0.05°C full range</td>
</tr>
<tr>
<td style="text-align: center;">Stability</td>
<td style="text-align: center;">±0.015°C full range</td>
</tr>
<tr>
<td style="text-align: center;">Axial uniformity at 40 mm (1.6 in)</td>
<td style="text-align: center;">±0.05°C full range</td>
</tr>
<tr>
<td style="text-align: center;">Radial gradient</td>
<td style="text-align: center;">±0.01°C full range</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="5">Loading effect</td>
<td style="text-align: center;">(with a 6.35 mm reference probe and three 6.35 mm probes)</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">±0.006°C full range</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">(versus display with one 6.35 mm probe)</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">±0.25°C at –95°C</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">±0.10°C at 140°C</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="2">Operating conditions</td>
<td style="text-align: center;">0°C to 35°C, 0% to 90% RH (non-condensing)</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">RH (non-condensing) &lt; 2000 m altitude</td>
</tr>
<tr>
<td style="text-align: center;">Environmental conditions for all specifications except temperature range</td>
<td style="text-align: center;">13°C to 33°C</td>
</tr>
<tr>
<td style="text-align: center;">Immersion (well) depth</td>
<td style="text-align: center;">160 mm (6.3 in)</td>
</tr>
<tr>
<td style="text-align: center;">Well diameter</td>
<td style="text-align: center;">30 mm (1.18 in)</td>
</tr>
<tr>
<td style="text-align: center;">Heating time<sup>1</sup></td>
<td style="text-align: center;">–95°C to 140°C: 40 min</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="3">Cooling time<sup>1</sup></td>
<td style="text-align: center;">23°C to –90°C: 80 min</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">23°C to –95°C: 90 min</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">140°C to 23°C: 60 min</td>
</tr>
<tr>
<td style="text-align: center;">Stabilization time<sup>2</sup></td>
<td style="text-align: center;">15 min</td>
</tr>
<tr>
<td style="text-align: center;">Resolution</td>
<td style="text-align: center;">0.01°</td>
</tr>
<tr>
<td style="text-align: center;">Display</td>
<td style="text-align: center;">LCD, °C or °F user-selectable</td>
</tr>
<tr>
<td style="text-align: center;">Size (H x W x D)</td>
<td style="text-align: center;">480 x 205 x 380 mm (18.8 x 8.0 x 14.9 in)</td>
</tr>
<tr>
<td style="text-align: center;">Weight</td>
<td style="text-align: center;">16 kg (35 lb)</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="2">Power requirements</td>
<td style="text-align: center;">100 V to 115 V (±10%) 50/60 Hz, 575 W</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">200 V to 230 V (±10%) 50/60 Hz, 575 W</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="2">System fuse ratings</td>
<td style="text-align: center;">115 V: 6.3 A T 250 V</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">230 V: 3.15 A T 250 V</td>
</tr>
<tr>
<td style="text-align: center;">4–20 mA fuse (-P model only)</td>
<td style="text-align: center;">50 mA F 250 V</td>
</tr>
<tr>
<td style="text-align: center;">Computer interface</td>
<td style="text-align: center;">RS-232, and USB Serial included</td>
</tr>
<tr>
<td style="text-align: center;">Safety</td>
<td style="text-align: center;">IEC 61010-1, Installation Category II, Pollution degree 2</td>
</tr>
<tr>
<td style="text-align: center;">Electromagnetic environment</td>
<td style="text-align: center;">IEC 61326-1: Basic</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="4">Refrigerants</td>
<td style="text-align: center;">R32 (Difluoromethane)</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">&lt; 20 g, ASHRAE safety group A2L</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">R704 (Helium)</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">&lt; 20 g, ASHRAE safety group A1</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table>
<tbody>
<tr>
<td style="text-align: center;" rowspan="5">Built-in reference thermometer readout accuracy (4-wire reference probe)<sup>3</sup></td>
<td style="text-align: center;">±0.010°C at –95°C</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">±0.013°C at –25°C</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">±0.015°C at 0°C</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">±0.020°C at 50°C</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">±0.025°C at 140°C</td>
</tr>
<tr>
<td style="text-align: center;">Reference resistance range</td>
<td style="text-align: center;">0 Ω to 400 Ω</td>
</tr>
<tr>
<td style="text-align: center;">Reference resistance accuracy<sup>4</sup></td>
<td style="text-align: center;">0 Ω to 42 Ω: ±0.0025 Ω<br />
42 Ω to 400 Ω: ±60 ppm of reading</td>
</tr>
<tr>
<td style="text-align: center;">Reference characterizations</td>
<td style="text-align: center;">ITS-90, CVD, IEC-751, resistance</td>
</tr>
<tr>
<td style="text-align: center;">Reference measurement capability</td>
<td style="text-align: center;">4-wire</td>
</tr>
<tr>
<td style="text-align: center;">Reference probe connection</td>
<td style="text-align: center;">6-pin din with INFO-CON technology</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="4">Built-in RTD thermometer readout accuracy</td>
<td style="text-align: center;">NI-120: ±0.015°C at 0°C</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">PT-100 (385): ±0.02°C at 0°C</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">(3926): ±0.02°C at 0°C</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">PT-100 (JIS): ±0.02°C at 0°C</td>
</tr>
<tr>
<td style="text-align: center;">RTD resistance range</td>
<td style="text-align: center;">0 Ω to 400 Ω</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="2">Resistance accuracy<sup>4</sup></td>
<td style="text-align: center;">0 Ω to 25 Ω: ±0.002 Ω</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">25 Ω to 400 Ω: ±80 ppm of reading</td>
</tr>
<tr>
<td style="text-align: center;">RTD characterizations</td>
<td style="text-align: center;">PT-100 (385), (JIS), (3926), NI-120, resistance</td>
</tr>
<tr>
<td style="text-align: center;">RTD measurement capability</td>
<td style="text-align: center;">2-wire, 3-wire, and 4-wire RTD with jumpers only</td>
</tr>
<tr>
<td style="text-align: center;">RTD connection</td>
<td style="text-align: center;">4-terminal input</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="11">Built-in TC thermometer readout accuracy<sup>5</sup></td>
<td style="text-align: center;">Type J: ±0.70°C at 140°C</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">K: ±0.75°C at 140°C</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">Type T: ±0.60°C at 140°C</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">E: ±0.60°C at 140°C</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">Type R: ±1.60°C at 140°C</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">Type S: ±1.60°C at 140°C</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">M: ±0.65°C at 140°C</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">Type L: ±0.65°C at 140°C</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;"> U: ±0.70°C at 140°C</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">Type N: ±0.75°C at 140°C</td>
</tr>
<tr>
<td class="nobold" style="text-align: center;">C: ±1.00°C at 140°C</td>
</tr>
<tr>
<td style="text-align: center;">TC millivolt range</td>
<td style="text-align: center;">–10 mV to 75 mV</td>
</tr>
<tr>
<td style="text-align: center;">Voltage accuracy</td>
<td style="text-align: center;">0.025% of reading +0.01 mV</td>
</tr>
<tr>
<td style="text-align: center;">Internal cold junction compensation accuracy</td>
<td style="text-align: center;">±0.35°C (ambient of 13°C to 33°C)</td>
</tr>
<tr>
<td style="text-align: center;">TC connection</td>
<td style="text-align: center;">Miniature connectors (ASTM E1684)</td>
</tr>
<tr>
<td style="text-align: center;">Built-in mA readout accuracy</td>
<td style="text-align: center;">0.02% of reading + 0.002 mA</td>
</tr>
<tr>
<td style="text-align: center;">mA range</td>
<td style="text-align: center;">Cal 4-22 mA, Spec 4-24 mA</td>
</tr>
<tr>
<td style="text-align: center;">mA connection</td>
<td style="text-align: center;">2 terminal input</td>
</tr>
<tr>
<td style="text-align: center;">Loop power function</td>
<td style="text-align: center;">24 V DC loop power</td>
</tr>
<tr>
<td style="text-align: center;">Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)</td>
<td style="text-align: center;">±0.005% of range per °C</td>
</tr>
</tbody>
</table>
<p class="nobold small-font">1. For ambient temperature of 23°C.<br />
2. Time from when the SETPOINT is reached to when the unit is within stability specification.<br />
3. The temperature range may be limited by the reference probe connected to the readout. The built-in reference accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors.<br />
4. Measurement accuracy specifications apply within the operating range and assume 4 wires for PRTs. With 3-wire RTDs add 0.05 Ω to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires.<br />
5. The thermocouple input readout is sensitive to EM fields in the frequency range of 500 MHz to 700 MHz.</p>
<p>&nbsp;</p>
<div></div>
</div>
</div>
</div>
</div>
</div>The post <a href="https://koueitrading.com/global/product/fluke-9190a-ultra-cool-field-metrology-well/">Fluke 9190A Ultra-Cool Field Metrology Well</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 9142 Field Metrology Well</title>
		<link>https://koueitrading.com/global/product/fluke-9142-field-metrology-well/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 03 Oct 2020 07:34:18 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125667</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 9142 Features Lightweight, portable, and fast Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current True reference thermometry with accuracy to ±0.01 °C On-board automation and documentation Metrology performance in accuracy, stability, uniformity, and loading Specifications Specification Details Temperature range at 23°C –25°C to 150°C (–13°F to 302°F) Display accuracy [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-9142-field-metrology-well/">Fluke 9142 Field Metrology Well</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 9142</p>
<h2>Features</h2>
<ul>
<li>Lightweight, portable, and fast</li>
<li>Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current</li>
<li>True reference thermometry with accuracy to ±0.01 °C</li>
<li>On-board automation and documentation</li>
<li>Metrology performance in accuracy, stability, uniformity, and loading</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-125673 size-full" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-143819.png" alt="9142" width="588" height="410" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-143819.png 588w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-143819-300x209.png 300w" sizes="auto, (max-width: 588px) 100vw, 588px" /></p>
<h2>Specifications</h2>
<div id="fluke-product-display-specs">
<div id="product-specs">
<div id="specification_content">
<div class="clickability">
<table>
<tbody>
<tr>
<th>Specification</th>
<th>Details</th>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Temperature range at 23°C</td>
<td style="text-align: center;">–25°C to 150°C (–13°F to 302°F)</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Display accuracy</td>
<td style="text-align: center;">±0.2°C full range</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Stability</td>
<td style="text-align: center;">±0.01°C full range</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Axial uniformity at 40 mm (1.6 in)</td>
<td style="text-align: center;">±0.05°C full range</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Radial uniformity</td>
<td style="text-align: center;">±0.01°C full range</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes)</td>
<td style="text-align: center;">±0.006°C full range</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Hysteresis</td>
<td style="text-align: center;">0.025</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Operating conditions</td>
<td style="text-align: center;">0°C to 50°C, 0% to 90% RH (non-condensing)</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Environmental conditions (for all specifications except temperature range)</td>
<td style="text-align: center;">13°C to 33°C</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Immersion (well) Depth</td>
<td style="text-align: center;">150 mm (5.9 in)</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Insert OD</td>
<td style="text-align: center;">30 mm (1.18 in)</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Heating time</td>
<td style="text-align: center;">16 min: 23°C to 140°C<br />
23 min: 23°C to 150°C<br />
25 min: –25°C to 150°C</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Cooling time</td>
<td style="text-align: center;">15 min: 23°C to –25°C<br />
25 min: 150°C to –23°C</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Resolution</td>
<td style="text-align: center;">0.01°</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Display</td>
<td style="text-align: center;">LCD, °C or °F user-selectable</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Size (H x W x D)</td>
<td style="text-align: center;">290 x 185 x 295 mm (11.4 x 7.3 x 11.6 in)</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Weight</td>
<td style="text-align: center;">8.16 kg (18 lb)</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Power requirements</td>
<td style="text-align: center;">100 V to 115 V (±10%) 50/60 Hz, 635 W<br />
230 V (±10%) 50/60 Hz, 575 W</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Computer interface</td>
<td style="text-align: center;">RS-232 interface</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Calibration</td>
<td style="text-align: center;">NVLAP accredited calibration included</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Automation</td>
<td style="text-align: center;">Use the 1586A Super-DAQ to automate temperature sensor calibration</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table>
<tbody>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Built-in reference thermometer readout accuracy (4-Wire Reference Probe)<sup>1</sup></td>
<td style="text-align: center;">±0.010°C at -25°C<br />
±0.015°C at 0°C<br />
±0.020°C at 50°C<br />
±0.025°C at 150°C<br />
±0.030°C at 200°C<br />
±0.040°C at 350°C<br />
±0.050°C at 420°C<br />
±0.070°C at 660°C</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Reference resistance range</td>
<td style="text-align: center;">0 ohms to 400 ohms</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Reference resistance accuracy<sup>2</sup></td>
<td style="text-align: center;">0 ohms to 42 ohms: ±0.0025 ohms<br />
42 ohms to 400 ohms: ±60 ppm of reading</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Reference characterizations</td>
<td style="text-align: center;">ITS-90, CVD, IEC-751, Resistance</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Reference measurement capability</td>
<td style="text-align: center;">4-wire</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Reference probe connection</td>
<td style="text-align: center;">6-pin Din with Infocon Technology</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Built-in RTD thermometer readout accuracy</td>
<td style="text-align: center;">NI-120: ±0.015°C at 0°C<br />
PT-100 (JIS): ±0.02°C at 0°C</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">RTD resistance range</td>
<td style="text-align: center;">0 ohms to 400 ohms</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">RTD resistance accuracy<sup>2</sup></td>
<td style="text-align: center;">0 ohms to 25 ohms: ±0.002 ohms<br />
25 ohms to 400 ohms: ±80 ppm of reading</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">RTD characterizations</td>
<td style="text-align: center;">PT-100 (385), (JIS), (3926), NI-120, Resistance</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">RTD measurement capability</td>
<td style="text-align: center;">4-wire RTD (2-,3-wire RTD w/ Jumpers only)</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">RTD connection</td>
<td style="text-align: center;">4 terminal input</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Built-in TC thermometer readout accuracy</td>
<td style="text-align: center;">Type J: ±0.7°C at 660°C<br />
Type K: ±0.8°C at 660°C<br />
T: ±0.8°C at 400°C<br />
Type E: ±0.7°C at 660°C<br />
R: ±1.4°C at 660°C<br />
Type S: ±1.5°C at 660°C<br />
M: ±1.4°C at 660°C<br />
Type L: ±0.7°C at 660°C<br />
U: ±0.75°C at 600°C<br />
Type N: ±0.9°C at 660°C<br />
Type C: ±1.1°C at 660°C</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">TC millivolt range</td>
<td style="text-align: center;">–10 mV to 75 mV</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Voltage accuracy</td>
<td style="text-align: center;">0.025% of reading + 0.01 mV</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Internal cold junction compensation accuracy</td>
<td style="text-align: center;">±0.35°C (ambient of 13°C to 33°C)</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">TC connection</td>
<td style="text-align: center;">Small connectors</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Built-in mA readout accuracy</td>
<td style="text-align: center;">0.02% of reading + 2 mV</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">mA range</td>
<td style="text-align: center;">Cal 4-22 mA, Spec 4-24 mA</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">mA connection</td>
<td style="text-align: center;">2 terminal input</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Loop power function</td>
<td style="text-align: center;">24 V DC loop power</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)</td>
<td style="text-align: center;">±0.005% of range per °C</td>
</tr>
</tbody>
</table>
<p class="nobold small-font">1. The temperature range may be limited by the reference probe connected to the readout. The Built-In Reference Thermometer Readout Accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors.<br />
2. Measurement accuracy specifications apply within the operating range and assume 4-wires for PRTs. With 3-wire RTDs add 0.05 ohms to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires.</p>
<p>&nbsp;</p>
<div></div>
</div>
</div>
</div>
</div>The post <a href="https://koueitrading.com/global/product/fluke-9142-field-metrology-well/">Fluke 9142 Field Metrology Well</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 9132/ 9133 Portable Infrared Calibrators</title>
		<link>https://koueitrading.com/global/product/fluke-9132-9133-portable-infrared-calibrators/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 03 Oct 2020 07:22:01 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125650</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 9132/ 9133 Features Certify IR pyrometers from –30 °C to 500 °C (–22 °F to 932 °F) Large 57 mm (2.25 in) blackbody target RTD reference well for contact temperature measurement Small, compact design in a blackbody calibrator Specifications Specifications 9133 9132 Temperature Range –30 °C to 150 °C at 23 [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-9132-9133-portable-infrared-calibrators/">Fluke 9132/ 9133 Portable Infrared Calibrators</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 9132/ 9133</p>
<h2>Features</h2>
<ul>
<li>Certify IR pyrometers from –30 °C to 500 °C (–22 °F to 932 °F)</li>
<li>Large 57 mm (2.25 in) blackbody target</li>
<li>RTD reference well for contact temperature measurement</li>
<li>Small, compact design in a blackbody calibrator</li>
</ul>
<p><img loading="lazy" decoding="async" class="alignleft wp-image-125654" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-142325.png" alt="9132/ 9133" width="323" height="197" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-142325.png 762w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-142325-300x183.png 300w" sizes="auto, (max-width: 323px) 100vw, 323px" /> <img loading="lazy" decoding="async" class="wp-image-125656 alignleft" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-142329.png" alt="" width="287" height="182" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-142329.png 732w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-142329-300x191.png 300w" sizes="auto, (max-width: 287px) 100vw, 287px" /></p>
<h2>Specifications</h2>
<table class="table" border="1" cellspacing="0" cellpadding="4">
<tbody>
<tr bgcolor="#e9eff4">
<td class="tableHead" style="text-align: center;">Specifications</td>
<td class="tableHead" style="text-align: center;"><strong>9133</strong></td>
<td class="tableHead" style="text-align: center;"><strong>9132</strong></td>
</tr>
<tr>
<td style="text-align: center;"><strong>Temperature Range</strong></td>
<td style="text-align: center;">–30 °C to 150 °C at 23 °C ambient<br />
(–22 °F to 302 °F at 73 °F ambient)</td>
<td style="text-align: center;">50 °C to 500 °C<br />
(122°F to 932°F)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Type of Calibration</strong></td>
<td style="text-align: center;">NIST traceable contact calibration</td>
<td style="text-align: center;">NIST traceable radiometric</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Accuracy</strong></td>
<td style="text-align: center;">± 0.4 °C (± 0.72 °F)</td>
<td style="text-align: center;">
<div>0.5 °C + 0.3 % of reading</div>
<div>0.8 °F + 0.3 % of reading</div>
</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Stability</strong></td>
<td style="text-align: center;">± 0.1 °C (± 0.18 °F)</td>
<td style="text-align: center;">± 0.1°C at 100°C<br />
(± 0.18°F at 212°F)<br />
± 0.3°C at 500°C<br />
(± 0.54°F at 932°F)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Target Size</strong></td>
<td style="text-align: center;" colspan="2">57 mm (2.25 in)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Target Emissivity</strong></td>
<td style="text-align: center;">
<div>0.95 (± 0.02 from 8 to 14 μm)</div>
<div></div>
</td>
<td style="text-align: center;">Radiometrically calibrated to 0.95</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Resolution</strong></td>
<td style="text-align: center;" colspan="2">0.1 °</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Heating Time</strong></td>
<td style="text-align: center;">15 minutes (25 °C to 150 °C)</td>
<td style="text-align: center;">30 minutes (50 °C to 500 °C)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Cooling Time</strong></td>
<td style="text-align: center;">15 minutes (25 °C to –20 °C)</td>
<td style="text-align: center;">30 minutes (500 °C to 100 °C)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Computer Interface</strong></td>
<td style="text-align: center;" colspan="2">RS-232 interface</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Power</strong></td>
<td style="text-align: center;">115 V ac (± 10 %), 1.5 A, or<br />
230 V ac (± 10 %), 1.0 A,<br />
switchable, 50/60 Hz, 200 W</td>
<td style="text-align: center;">115 V ac (± 10 %), 3 A or<br />
230 V ac (± 10 %), 1.5 A,<br />
switchable, 50/60 Hz, 340 W</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Size (HxWxD)<br />
</strong></td>
<td style="text-align: center;">152 x 286 x 267 mm<br />
(6 x 11.25 x 10.5 in)</td>
<td style="text-align: center;">102 x 152 x 178 mm<br />
(4 x 6 x 7 in )</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Weight</strong></td>
<td style="text-align: center;">4.6 kg (10 lb)</td>
<td style="text-align: center;">1.8 kg (4 lb)</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-9132-9133-portable-infrared-calibrators/">Fluke 9132/ 9133 Portable Infrared Calibrators</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 4180/ 4181 Precision Infrared Calibrators</title>
		<link>https://koueitrading.com/global/product/fluke-4180-4181-precision-infrared-calibrators/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 03 Oct 2020 07:13:00 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125630</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 4180/ 4181 Features Calibrated radiometrically for meaningful, consistent results. Accredited calibration included Accurate, reliable performance from –15 °C to 500 °C Large target size of 152 mm (6 in) is required for calibrating most thermometers. Light instrument weight of 8.6 kg (19 lbs) makes it easy to lift and carry. Intuitive, [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-4180-4181-precision-infrared-calibrators/">Fluke 4180/ 4181 Precision Infrared Calibrators</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 4180/ 4181</p>
<h2>Features</h2>
<ul class="PrdPlainText">
<li>Calibrated radiometrically for meaningful, consistent results.</li>
<li>Accredited calibration included</li>
<li>Accurate, reliable performance from –15 °C to 500 °C</li>
<li>Large target size of 152 mm (6 in) is required for calibrating most thermometers.</li>
<li>Light instrument weight of 8.6 kg (19 lbs) makes it easy to lift and carry.</li>
<li>Intuitive, easy-to-read display that indicates when temperature is stable.</li>
</ul>
<p><img loading="lazy" decoding="async" class="alignleft wp-image-125640" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-141812.png" alt="4180/ 4181" width="252" height="362" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-141812.png 421w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-141812-209x300.png 209w" sizes="auto, (max-width: 252px) 100vw, 252px" /> <img loading="lazy" decoding="async" class="wp-image-125641 alignleft" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-141830.png" alt="" width="277" height="369" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-141830.png 466w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-141830-225x300.png 225w" sizes="auto, (max-width: 277px) 100vw, 277px" /></p>
<h2>Specifications</h2>
<table>
<tbody>
<tr>
<th>Specification</th>
<th>4180</th>
<th>4181</th>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Temperature range (@ 23 °C ambient, 0.95 emissivity)</td>
<td style="text-align: center;">–15 °C to 120 °C</td>
<td style="text-align: center;">35 °C to 500 °C</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Display accuracy<sup>1</sup></td>
<td style="text-align: center;">± 0.40 °C at –15 °C<br />
± 0.40 °C at 0 °C<br />
± 0.50 °C at 50 °C<br />
± 0.50 °C at 100 °C<br />
± 0.55 °C at 120 °C</td>
<td style="text-align: center;">± 0.35 °C at 35 °C<br />
± 0.50 °C at 100 °C<br />
± 0.70 °C at 200 °C<br />
± 1.20 °C at 350 °C<br />
± 1.60 °C at 500 °C</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Stability</td>
<td style="text-align: center;">± 0.10 °C at –15 °C<br />
± 0.05 °C at 0 °C<br />
± 0.10 °C at 120 °C</td>
<td style="text-align: center;">± 0.05 °C at 35 °C<br />
± 0.20 °C at 200 °C<br />
± 0.40 °C at 500 °C</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Uniformity (5.0 in dia of center of target)<sup>2</sup></td>
<td style="text-align: center;">± 0.15 °C at –15 °C<br />
± 0.10 °C at 0 °C<br />
± 0.25 °C at 120 °C</td>
<td style="text-align: center;">± 0.10 °C at 35 °C<br />
± 0.50 °C at 200 °C<br />
± 1.00 °C at 500 °C</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Uniformity (2.0 in dia of center of target)<sup>2</sup></td>
<td style="text-align: center;">± 0.10 °C at –15 °C<br />
± 0.10 °C at 0 °C<br />
± 0.20 °C at 120 °C</td>
<td style="text-align: center;">± 0.10 °C at 35 °C<br />
± 0.25 °C at 200 °C<br />
± 0.50 °C at 500 °C</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Heating time</td>
<td style="text-align: center;">15 min: –15 °C to 120 °C<br />
14 min: 23 °C to 120 °C</td>
<td style="text-align: center;">45 min: 35 °C to 500 °C</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Cooling time</td>
<td style="text-align: center;">15 min: 120 °C to 23 °C<br />
20 min: 23 °C to –15 °C</td>
<td style="text-align: center;">100 min: 500 °C to 35 °C<br />
40 min: 500 °C to 100 °C</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Stabilization time</td>
<td style="text-align: center;" colspan="2">10 minutes</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Nominal emissivity<sup>3</sup></td>
<td style="text-align: center;" colspan="2">0.95</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Thermometer emissivity compensation</td>
<td style="text-align: center;" colspan="2">0.9 to 1.0</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Target diameter</td>
<td style="text-align: center;" colspan="2">152.4 mm (6 in)</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Computer interface</td>
<td style="text-align: center;" colspan="2">RS-232</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Power</td>
<td style="text-align: center;">115 V ac (± 10%), 6.3 A, 50/60 Hz, 630 W<br />
230 V ac (± 10%), 3.15 A, 50/60 Hz, 630 W</td>
<td style="text-align: center;">115 V ac (± 10%), 10 A, 50/60 Hz, 1000 W<br />
230 V ac (± 10%), 5 A, 50/60 Hz, 1000 W</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Fuse(s)</td>
<td style="text-align: center;">115 V ac 6.3 A, 250 V, slow blow<br />
230 V ac 3.15 A, 250 V, T</td>
<td style="text-align: center;">115 V ac 10 A, 250 V, fast blow<br />
230 V ac 5 A, 250 V, F</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Size (HxWxD)</td>
<td style="text-align: center;">356 mm x 241 mm x 216 mm (14 in x 9.5 in x 8.5 in)</td>
<td style="text-align: center;">356 mm x 241 mm x 216 mm (14 in x 9.5 in x 8.5 in)</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Weight</td>
<td style="text-align: center;">9.1 kg (20 lb)</td>
<td style="text-align: center;">9.5 kg (21 lb)</td>
</tr>
</tbody>
</table>
<p><strong>Notes:</strong><br />
1. For 8 µm to 14 µm spectral band thermometers with emissivity set between 0.9 and 1.0.<br />
2. The uniformity specification refers to how IR thermometers with different spot sizes both focused at the center of the target will measure the same temperature.<br />
3. The target has a nominal emissivity of 0.95, however it is radiometrically calibrated to minimize emissivity related uncertainties.</p>
<p>&nbsp;</p>
<div></div>The post <a href="https://koueitrading.com/global/product/fluke-4180-4181-precision-infrared-calibrators/">Fluke 4180/ 4181 Precision Infrared Calibrators</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 7900 Controller for Rosemount-Designed Baths</title>
		<link>https://koueitrading.com/global/product/fluke-7900-controller-for-rosemount-designed-baths/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 03 Oct 2020 07:06:25 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125621</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 7900 Features All the features of the Fluke Calibration 2100 Controller Installs easily Two independent over-temperature cutout circuits Specification Specification Details Temperature control range –100 °C to 400 °C Optional ranges None Stability ± 0.003 (± 0.001 typical) Stabilization time 30 minutes Display accuracy ± 1 °C Cooling control LN2 – [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-7900-controller-for-rosemount-designed-baths/">Fluke 7900 Controller for Rosemount-Designed Baths</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 7900</p>
<h2>Features</h2>
<ul>
<li>
<div>All the features of the Fluke Calibration 2100 Controller</div>
</li>
<li>
<div>Installs easily</div>
</li>
<li>
<div>Two independent over-temperature cutout circuits</div>
</li>
</ul>
<h2>Specification</h2>
<table>
<tbody>
<tr>
<th>Specification</th>
<th>Details</th>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Temperature control range</td>
<td style="text-align: center;">–100 °C to 400 °C</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Optional ranges</td>
<td style="text-align: center;">None</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Stability</td>
<td style="text-align: center;">± 0.003 (± 0.001 typical)</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Stabilization time</td>
<td style="text-align: center;">30 minutes</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Display accuracy</td>
<td style="text-align: center;">± 1 °C</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Cooling control</td>
<td style="text-align: center;">LN<sub>2</sub> – automatic</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Heating control</td>
<td style="text-align: center;">2-position, firmware or user controlled</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Firmware high-temp cutout</td>
<td style="text-align: center;">Yes, volatile, programmable (independent of the controller)</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Hardware high-temp cutout</td>
<td style="text-align: center;">Thermocouple controlled</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Memory</td>
<td style="text-align: center;">Non-volatile; 8 programmable set-points, each with ramp and soak features</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Programmable soak time</td>
<td style="text-align: center;">1 to 500 minutes</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Control sensor</td>
<td style="text-align: center;">100-ohm PRT; alpha = 0.00385</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Interface</td>
<td style="text-align: center;">RS-232 and IEEE standard</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Operating temperature</td>
<td style="text-align: center;">5 °C to 50 °C</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Operating voltage</td>
<td style="text-align: center;">115 VAC (±10 %), 60 Hz</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">CE mark</td>
<td style="text-align: center;">Contact Fluke Calibration</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Current rating</td>
<td style="text-align: center;">20 amps maximum</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Dimensions (W x H X D)</td>
<td style="text-align: center;">311 x 114 x 279 mm (12.25 x 4.5 x 11 in)</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Weight</td>
<td style="text-align: center;">4 kg (9 lb)</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Installation</td>
<td style="text-align: center;">Freestanding or rack-mounted with optional hardware</td>
</tr>
</tbody>
</table>
<div></div>The post <a href="https://koueitrading.com/global/product/fluke-7900-controller-for-rosemount-designed-baths/">Fluke 7900 Controller for Rosemount-Designed Baths</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 2100/ 2200 Benchtop Temperature Controllers</title>
		<link>https://koueitrading.com/global/product/fluke-2100-2200-benchtop-temperature-controllers/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 03 Oct 2020 06:58:15 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125611</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 2100/ 2200 Features Most stable temperature controllers available Resolution as high as 0.00018°C RS-232 interface included for automating applications Specifications Specification Details Temperature range 2100: –100 °C to 670 °C 2200: –100 °C to 800 °C Control stability 2100: ±0.0005 °C to ±0.002 °C 2200: ±0.005 °C to ±0.02 °C (depends [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-2100-2200-benchtop-temperature-controllers/">Fluke 2100/ 2200 Benchtop Temperature Controllers</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 2100/ 2200</p>
<h2>Features</h2>
<ul>
<li>Most stable temperature controllers available</li>
<li>Resolution as high as 0.00018°C</li>
<li>RS-232 interface included for automating applications</li>
</ul>
<h2>Specifications</h2>
<table>
<tbody>
<tr>
<th>Specification</th>
<th>Details</th>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Temperature range</td>
<td style="text-align: center;"><strong>2100</strong>: –100 °C to 670 °C<br />
<strong>2200</strong>: –100 °C to 800 °C</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Control stability</td>
<td style="text-align: center;"><strong>2100</strong>: ±0.0005 °C to ±0.002 °C<br />
<strong>2200</strong>: ±0.005 °C to ±0.02 °C<br />
(depends on system design)</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Display accuracy (with probes shown below)</td>
<td style="text-align: center;">±1.0 °C without system calibration</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Display resolution</td>
<td style="text-align: center;">0.01 °</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Set-point resolution</td>
<td style="text-align: center;"><strong>2100</strong>: 0.0002 ° in high-resolution mode<br />
<strong>2200</strong>: 0.01 °</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Auxiliary and heater output</td>
<td style="text-align: center;"><strong>2100</strong>: 100–125 nominal VAC or 230 nominal VAC (internally switchable), 50/60 Hz, 10 A max.<br />
<strong>2200</strong>: 100–230 VAC, 50/60 Hz, 10 A max.</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Heater output</td>
<td style="text-align: center;">Solid-state relay</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Dimensions (H x W x D)</td>
<td style="text-align: center;"><strong>2100</strong>: 72 x 172 x 250 mm (2.83 x 6.75 x 9.86 in)<br />
<strong>2200</strong>: 72 x 114 x 178 mm (2.85 x 4.5 x 7 in)</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">Probes</td>
<td style="text-align: center;"><strong>2620</strong>: RTD, 280 x 4.8 mm (11 x 0.187 in), –100 to 550 °C<br />
<strong>2622</strong>: RTD, 229 x 4.8 mm (9 x 0.187 in), –100 to 550 °C<br />
<strong>2624</strong>: RTD, 356 x 4.8 mm (14 x 0.187 in), –100 to 550 °C<br />
<strong>2611</strong>: Thermistor, 229 x 5.5 mm (9 x 0.218 in), –10 °C to 110 °C (2100 controller only)</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<div></div>The post <a href="https://koueitrading.com/global/product/fluke-2100-2200-benchtop-temperature-controllers/">Fluke 2100/ 2200 Benchtop Temperature Controllers</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 7911A2 Constant Temperature Ice Bath</title>
		<link>https://koueitrading.com/global/product/fluke-7911a2-constant-temperature-ice-bath/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 03 Oct 2020 06:52:36 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125602</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 7911A2 Features Lower uncertainty zero-point (to ± 0.002 °C uniformity) Affordable—amazing price for this uniformity and stability Many probes can be checked/calibrated at once Specifications Specifications Uniformity ± 0.002 °C† Stability ± 0.002 °C† Optimal Temp. Zone 64 mm dia. x 203 mm D (2.5 x 8 in) Size 185 mm [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-7911a2-constant-temperature-ice-bath/">Fluke 7911A2 Constant Temperature Ice Bath</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 7911A2</p>
<h2>Features</h2>
<ul>
<li>Lower uncertainty zero-point (to ± 0.002 °C uniformity)</li>
<li>Affordable—amazing price for this uniformity and stability</li>
<li>Many probes can be checked/calibrated at once</li>
</ul>
<h2>Specifications</h2>
<table class="table" border="1" cellspacing="0" cellpadding="4">
<tbody>
<tr>
<td colspan="2" bgcolor="#e9eff4">
<h3>Specifications</h3>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Uniformity</strong></td>
<td style="text-align: center;" valign="top">± 0.002 °C<sup>†</sup></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Stability</strong></td>
<td style="text-align: center;" valign="top">± 0.002 °C<sup>†</sup></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Optimal Temp. Zone</strong></td>
<td style="text-align: center;" valign="top">64 mm dia. x 203 mm D (2.5 x 8 in)</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Size</strong></td>
<td style="text-align: center;" valign="top">185 mm dia. x 490 mm D (7 x 19 in)</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Tank Capacity</strong></td>
<td style="text-align: center;" valign="top">5 Liters, 150 mm dia. x 300 mm D (6 x 12 in)</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Weight</strong></td>
<td style="text-align: center;" valign="top">13.5 lb (6.1 kg)</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Power</strong></td>
<td style="text-align: center;" valign="top">115 V ac (± 10 %), 60 Hz, 1 A or<br />
230 V ac (± 10 %), 50 Hz, 0.5 A</td>
</tr>
<tr>
<td colspan="2" valign="top"><sup>†</sup>based on a properly made ice bath mixture</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-7911a2-constant-temperature-ice-bath/">Fluke 7911A2 Constant Temperature Ice Bath</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 7009/7108/7015 Resistor Baths</title>
		<link>https://koueitrading.com/global/product/fluke-7009-7108-7015-resistor-baths/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 03 Oct 2020 06:48:50 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125594</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 7009/7108/7015 Features Three size options for any quantity of resistors Stability to ±0.0007 °C Independent high- and low-temperature cutout circuit Minimal long-term drift Specifications Specifications 7015 7009 7108 Range 0 °C to 50 °C† 0 °C to 50 °C† 20 °C to 30 °C Stability at 25 °C ±0.0007 °C (water) [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-7009-7108-7015-resistor-baths/">Fluke 7009/7108/7015 Resistor Baths</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 7009/7108/7015</p>
<h2>Features</h2>
<ul>
<li>Three size options for any quantity of resistors</li>
<li>Stability to ±0.0007 °C</li>
<li>Independent high- and low-temperature cutout circuit</li>
<li>Minimal long-term drift</li>
</ul>
<h2>Specifications</h2>
<table class="table" border="1" cellspacing="0" cellpadding="4">
<tbody>
<tr bgcolor="#e9eff4">
<td class="tableHead">
<h3>Specifications</h3>
</td>
<td class="tableHead" align="center">
<h3><strong>7015</strong></h3>
</td>
<td class="tableHead" align="center">
<h3><strong>7009</strong></h3>
</td>
<td class="tableHead" align="center">
<h3><strong>7108</strong></h3>
</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><strong>Range</strong></td>
<td style="text-align: center;" align="center" valign="top">0 °C to 50 °C<sup>†</sup></td>
<td style="text-align: center;" align="center" valign="top">0 °C to 50 °C<sup>†</sup></td>
<td style="text-align: center;" align="center" valign="top">20 °C to 30 °C</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><strong>Stability at 25 °C</strong></td>
<td style="text-align: center;" colspan="2" align="center" valign="top">±0.0007 °C (water)<br />
±0.001 °C (mineral oil 5011)</td>
<td style="text-align: center;" align="center" valign="top">±0.002 °C (water)<br />
±0.004 °C (mineral oil 5011)</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><strong>Uniformity</strong></td>
<td colspan="2" align="center" valign="top">±0.003 °C at 25 °C (water)<br />
±0.005 °C at 25 °C (mineral oil 5011)</td>
<td align="center" valign="top">±0.005 °C (water)<br />
±0.008 °C (mineral oil 5011)</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><strong>Temperature Setting</strong></td>
<td colspan="3" align="center" valign="top">Digital display with push-button data entry</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><strong>Set-Point Resolution</strong></td>
<td style="text-align: center;" colspan="3" align="center" valign="top">0.002 °C; high-resolution mode, 0.00003 °C</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><strong>Display Resolution</strong></td>
<td colspan="3" align="center" valign="top">0.01 °C</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><strong>Digital Setting Accuracy</strong></td>
<td style="text-align: center;" colspan="2" align="center" valign="top">±1 °C</td>
<td style="text-align: center;" align="center" valign="top">±0.5 °C</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><strong>Digital Setting Repeatability</strong></td>
<td colspan="3" align="center" valign="top">±0.01 °C</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><strong>Heaters</strong></td>
<td style="text-align: center;" colspan="2" align="center" valign="top">500 and 1000 Watts</td>
<td style="text-align: center;" align="center" valign="top">Peltier heating/cooling</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><strong>Cooling Capacity</strong></td>
<td colspan="2" align="center" valign="top">100 to 200 Watts</td>
<td align="center" valign="top">100 W in ambient 23 °C</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><strong>Access Opening</strong></td>
<td style="text-align: center;" align="center" valign="top">699 x 279 mm (27.5 x 11 in)</td>
<td style="text-align: center;" align="center" valign="top">699 x 559 mm (27.5 x 22 in)</td>
<td style="text-align: center;" align="center" valign="top">356 x 356 mm (14 x 14 in)</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><strong>Bath Chamber Dimensions (HxWxD) (unobstructed space)</strong></td>
<td align="center" valign="top">699 x 279 x 330 mm<br />
(27.5 x 11 x 13 in)</td>
<td align="center" valign="top">669 x 559 x 330 mm<br />
(27.5 x 22 x 13 in)</td>
<td align="center" valign="top">356 x 203 x 355 mm<br />
(14 x 8 x 14 in)</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><strong>Depth</strong></td>
<td style="text-align: center;" colspan="2" align="center" valign="top">330 mm (13 in)</td>
<td style="text-align: center;" align="center" valign="top">203 mm (8 in)</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><strong>Wetted Parts</strong></td>
<td colspan="2" align="center" valign="top">304 stainless steel</td>
<td align="center" valign="top">Tank: 304 stainless steel<br />
Resistor rack: hard-anodized, perforated aluminum</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><strong>Safety Cutout</strong></td>
<td style="text-align: center;" colspan="2" align="center" valign="top">Factory-set high temperature</td>
<td style="text-align: center;" align="center" valign="top">n/a</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><strong>Power</strong></td>
<td align="center" valign="top">115 VAC (±10 %), 60 Hz, 15 A or 230 VAC, 50 or 60 Hz, 8 A, specify</td>
<td align="center" valign="top">230 VAC (±10 %), 50 or 60 Hz, 12 A (specify frequency)</td>
<td align="center" valign="top">115 VAC (±10 %), 50/60 Hz, 3 A or 230 VAC (±10 %), 50/60 Hz, 1.6 A, specify</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><strong>Volume</strong></td>
<td style="text-align: center;" align="center" valign="top">95 liters (25 gallons)</td>
<td style="text-align: center;" align="center" valign="top">167 liters (44 gallons)</td>
<td style="text-align: center;" align="center" valign="top">51 liters (13.2 gallons)</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><strong>Weight</strong></td>
<td align="center" valign="top">141 kg (310 lb.)</td>
<td align="center" valign="top">150 kg (330 lb.)</td>
<td align="center" valign="top">35 kg (75 lb.)</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><strong>Size (HxWxD)</strong></td>
<td style="text-align: center;" align="center" valign="top">1219 x 1118 x 559 mm<br />
(48 x 44 x 22 in)</td>
<td style="text-align: center;" align="center" valign="top">1092 x 1130 x 864 mm<br />
(43 x 44.5 x 34 in)</td>
<td style="text-align: center;" align="center" valign="top">489 x 413 x 559 mm<br />
(19.25 x 22 x 25 in)</td>
</tr>
<tr valign="top">
<td style="text-align: center;" valign="top"><strong>Automation</strong></td>
<td colspan="3" valign="top">Use the 1586A Super-DAQ to automate temperature sensor calibration</td>
</tr>
<tr valign="top">
<td colspan="4"><sup>†</sup>Although the 7015 and 7009 baths are capable of reaching higher temperatures, they are designed for use with standard resistors. Therefore, the soft cutout of the instrument has been set at the factory to 50°C to protect standard resistors placed in the bath.</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-7009-7108-7015-resistor-baths/">Fluke 7009/7108/7015 Resistor Baths</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 6054/6055/7007 Deep-Well Baths</title>
		<link>https://koueitrading.com/global/product/fluke-6054-6055-7007-deep-well-baths/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 03 Oct 2020 06:43:50 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125586</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 6054/6055/7007 Features Constant liquid levels through concentric-tube design Special design for sighting LIG thermometers Depth up to 60 cm (24 in) Optional interface packages control all settings Specifications 7007 6054 6055 Range –5 °C to 110 °C 50 °C to 300 °C 200 °C to 550 °C Temperature Stability ± 0.001 [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-6054-6055-7007-deep-well-baths/">Fluke 6054/6055/7007 Deep-Well Baths</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 6054/6055/7007</p>
<h2>Features</h2>
<ul>
<li>Constant liquid levels through concentric-tube design</li>
<li>Special design for sighting LIG thermometers</li>
<li>Depth up to 60 cm (24 in)</li>
<li>Optional interface packages control all settings</li>
</ul>
<h2>Specifications</h2>
<div id="quicktabs-tabs-wrapper"></div>
<div id="quicktabs_container_product_details" class="quicktabs_main quicktabs-style-nostyle">
<div id="quicktabs_tabpage_product_details_2" class="quicktabs_tabpage">
<div class="view view-product-details view-id-product_details view-display-id-block_1 view-dom-id-4 view-product-details view-id-product_details view-display-id-block_1 view-dom-id-4">
<div class="view-content">
<div class="views-row views-row-1 views-row-odd views-row-first views-row-last">
<div class="views-field-field-product-specifications-value">
<div class="field-content">
<table class="table" border="1" cellspacing="0" cellpadding="5">
<tbody>
<tr bgcolor="#dde6ed">
<td>
<h2></h2>
</td>
<td>
<h3 style="text-align: center;"><strong>7007</strong></h3>
</td>
<td style="text-align: center;">
<h3><strong>6054</strong></h3>
</td>
<td>
<h3 style="text-align: center;"><strong>6055</strong></h3>
</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Range</strong></td>
<td style="text-align: center;">–5 °C to 110 °C</td>
<td style="text-align: center;">50 °C to 300 °C</td>
<td style="text-align: center;">200 °C to 550 °C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Temperature Stability</strong></td>
<td style="text-align: center;">± 0.001 °C at 0 °C (water/ethanol)<br />
± 0.001 °C at 25 °C (water)<br />
0.003 °C at 100 °C (oil 5012)</td>
<td style="text-align: center;">± 0.003 °C at 100 °C (oil 5012)<br />
± 0.005 °C at 300 °C (oil 5017)</td>
<td style="text-align: center;">± 0.003 °C at 200 °C (salt)<br />
± 0.01 °C at 550 °C (salt)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Temperature Uniformity</strong></td>
<td style="text-align: center;">± 0.004 °C at 0 °C (ethanol)<br />
± 0.007 °C at 100 °C (oil 5012)</td>
<td style="text-align: center;">± 0.007 °C at 100 °C (oil 5012)<br />
± 0.015 °C at 300 °C (oil 5017)</td>
<td style="text-align: center;">± 0.005 °C at 200 °C (salt)<br />
± 0.010 °C at 550 °C (salt)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Temperature Setting</strong></td>
<td style="text-align: center;" colspan="3">Digital display with push-button data entry</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Set-Point Resolution</strong></td>
<td style="text-align: center;">0.002 °C, high res. 0.00003 °C</td>
<td style="text-align: center;" colspan="2">0.01 °C, high res. 0.00018 °C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Display Temperature Resolution</strong></td>
<td style="text-align: center;" colspan="3">0.01 °C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Digital Setting Accuracy</strong></td>
<td style="text-align: center;" colspan="3">± 1 °C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Digital Setting Repeatability</strong></td>
<td style="text-align: center;">± 0.005 °C</td>
<td style="text-align: center;" colspan="2">± 0.01 °C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Heaters</strong></td>
<td style="text-align: center;">250 to 1000 W</td>
<td style="text-align: center;">250 to 1000 W</td>
<td style="text-align: center;">260 to 2080 W</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Working Area</strong></td>
<td style="text-align: center;">178 mm dia. (7 in)</td>
<td style="text-align: center;">196 mm dia. (7.7 in)</td>
<td style="text-align: center;">107 mm dia. (4.2 in)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Depth</strong></td>
<td style="text-align: center;">24 in</td>
<td style="text-align: center;">24 in</td>
<td style="text-align: center;">24 in</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Wetted Parts</strong></td>
<td style="text-align: center;" colspan="3">304 stainless steel</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Power</strong></td>
<td style="text-align: center;">230 V ac (± 10 %), 50 or 60 Hz, 15 A<br />
(Specify frequency, contact Fluke Calibration if CE<br />
mark required.)</td>
<td style="text-align: center;">230 V ac (± 10 %), 50/60 Hz,<br />
15 A max</td>
<td style="text-align: center;">230 V ac (± 10 %), 50/60 Hz, 15 A</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Volume</strong></td>
<td style="text-align: center;">42 liters (11.2 gal)</td>
<td style="text-align: center;">50 liters (13.2 gal)</td>
<td style="text-align: center;">19.8 liters<br />
(5.2 gal, 43 kg [95 lb] of bath salt)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Size (D x W x H)</strong></td>
<td style="text-align: center;">470 x 775 x 194 mm to working surface (18.5 x 30.5 x 47 in), 1397 mm (55 in) to top of stir motor, 914 mm (36 in) to control panel</td>
<td style="text-align: center;">572 x 762 x 1219 mm to working surface (22.5 x 30 x 48 in), 1422 mm (56 in) to top of stir motor box, 914 mm (36 in) to control panel</td>
<td style="text-align: center;">572 x 775 x 1219 mm to working surface (22.5 x 30.5 x 48 in), 1524 mm (60 in) to top of stir motor box, 914 mm (36 in) to control panel</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Distance from Line of Sight to Top of Fluid</strong></td>
<td style="text-align: center;">9.5 mm (3/8 in)</td>
<td style="text-align: center;" colspan="2">15.9 mm (5/8 in)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Automation </strong></td>
<td style="text-align: center;" colspan="3">Use the 1586A Super-DAQ to automate temperature sensor calibration. For IEEE-488, add the 2001-IEEE to the automation package.</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Weight</strong></td>
<td style="text-align: center;" colspan="3">70.8 kg (156 lb)</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>The post <a href="https://koueitrading.com/global/product/fluke-6054-6055-7007-deep-well-baths/">Fluke 6054/6055/7007 Deep-Well Baths</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 7060/7080 Really Cold Temperature Calibration Baths</title>
		<link>https://koueitrading.com/global/product/fluke-7060-7080-really-cold-temperature-calibration-baths/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 03 Oct 2020 06:21:30 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125561</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 7060/7080 Features Self-contained refrigeration—no LN2 or chiller required Temperatures as low as –80 °C in real metrology baths Best stability and uniformity available at –80 °C and below Large working areas for increased throughput Specifications Specifications 7060 7080 Range −60 °C to 110 °C −80 °C to 110 °C Stability ±0.0025 °C [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-7060-7080-really-cold-temperature-calibration-baths/">Fluke 7060/7080 Really Cold Temperature Calibration Baths</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 7060/7080</p>
<h2>Features</h2>
<ul>
<li>Self-contained refrigeration—no LN<sub>2</sub> or chiller required</li>
<li>Temperatures as low as –80 °C in real metrology baths</li>
<li>Best stability and uniformity available at –80 °C and below</li>
<li>Large working areas for increased throughput</li>
</ul>
<h2>Specifications</h2>
<table class="table" border="1" cellspacing="0" cellpadding="4">
<tbody>
<tr bgcolor="#e9eff4">
<td class="tableHead">Specifications</td>
<td class="tableHead" align="center">7060</td>
<td class="tableHead" align="center">7080</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Range</strong></td>
<td style="text-align: center;" align="center">−60 °C to 110 °C</td>
<td style="text-align: center;" align="center">−80 °C to 110 °C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Stability</strong></td>
<td align="center">±0.0025 °C at −60 °C (methanol)<br />
±0.002 °C at 0 °C (methanol)<br />
±0.0015 °C at 25 °C (water)<br />
±0.003 °C at 100 °C (oil 5012)</td>
<td align="center">±0.0025 °C at −80 °C (methanol)<br />
±0.0015 °C at 0 °C (methanol)<br />
±0.0015 °C at 25 °C (water)<br />
±0.003 °C at 100 °C (oil 5012)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Uniformity</strong></td>
<td style="text-align: center;" align="center">±0.005 °C at −60 °C (methanol)<br />
±0.005 °C at 0 °C (methanol)<br />
±0.003 °C at 25 °C (water)<br />
±0.005 °C at 100 °C (oil 5012)</td>
<td style="text-align: center;" align="center">±0.007 °C at −80 °C (methanol)<br />
±0.005 °C at 0 °C (methanol)<br />
±0.003 °C at 25 °C (water)<br />
±0.005 °C at 100 °C (oil 5012)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Temperature Setting</strong></td>
<td style="text-align: center;" colspan="2">Digital display with push-button data entry</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Set-Point Resolution</strong></td>
<td style="text-align: center;" colspan="2">0.01 °C; high-resolution mode, 0.00007 °C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Display Resolution</strong></td>
<td style="text-align: center;" colspan="2">0.01 °C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Digital Setting Accuracy</strong></td>
<td style="text-align: center;" colspan="2">±1 °C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Digital Setting Repeatability</strong></td>
<td style="text-align: center;" colspan="2">±0.01 °C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Heaters</strong></td>
<td style="text-align: center;" colspan="2">500 and 1000 Watts</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Access Opening</strong></td>
<td style="text-align: center;" colspan="2">127 x 254 mm (5 x 10 in)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Depth</strong></td>
<td style="text-align: center;" colspan="2">305 mm (12 in)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Wetted Parts</strong></td>
<td style="text-align: center;" colspan="2">304 stainless steel</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Power</strong></td>
<td style="text-align: center;" colspan="2">230 VAC (±10 %), 50 or 60 Hz, 13 A, single phase, specify frequency</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Volume</strong></td>
<td style="text-align: center;" colspan="2">27 liters (7.2 gallons)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Weight</strong></td>
<td style="text-align: center;" colspan="2">159 kg (350 lb.)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Size (HxWxD)</strong></td>
<td style="text-align: center;" colspan="2">1168 x 775 x 483 mm (46 x 30.5 x 19 in)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Automation </strong></td>
<td style="text-align: center;" colspan="2">Use the 1586A Super-DAQ to automate temperature sensor calibration</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-7060-7080-really-cold-temperature-calibration-baths/">Fluke 7060/7080 Really Cold Temperature Calibration Baths</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 6020 High Temperature Calibration Oil Bath</title>
		<link>https://koueitrading.com/global/product/fluke-6020-high-temperature-calibration-oil-bath/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 03 Oct 2020 06:16:58 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125550</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 6020 Features Large-capacity tanks for higher productivity Calibrations up to 300 °C Built-in cooling coils for faster cooling Stability to ±0.001 °C Specifications Specifications 6020 Range 40 °C to 300 °C† Stability ±0.001 °C at 40 °C (water) ±0.003 °C at 100 °C (oil 5012) ±0.005 °C at 300 °C (oil [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-6020-high-temperature-calibration-oil-bath/">Fluke 6020 High Temperature Calibration Oil Bath</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 6020</p>
<h2>Features</h2>
<ul>
<li>Large-capacity tanks for higher productivity</li>
<li>Calibrations up to 300 °C</li>
<li>Built-in cooling coils for faster cooling</li>
<li>Stability to ±0.001 °C</li>
</ul>
<h2>Specifications</h2>
<table class="table" border="1" cellspacing="0" cellpadding="5">
<tbody>
<tr bgcolor="#e9eff4">
<td colspan="2">Specifications</td>
</tr>
<tr>
<td valign="top"></td>
<td align="center" valign="top"><strong>6020</strong></td>
</tr>
<tr>
<td valign="top"><strong>Range</strong></td>
<td align="center" valign="top">40 °C to 300 °C<sup>†</sup></td>
</tr>
<tr>
<td valign="top"><strong>Stability</strong></td>
<td align="center" valign="top">±0.001 °C at 40 °C (water)<br />
±0.003 °C at 100 °C (oil 5012)<br />
±0.005 °C at 300 °C (oil 5017)</td>
</tr>
<tr>
<td valign="top"><strong>Uniformity</strong></td>
<td align="center" valign="top">±0.002 °C at 40 °C (water)<br />
±0.004 °C at 100 °C (oil 5012)<br />
±0.012 °C at 300 °C (oil 5017)</td>
</tr>
<tr>
<td valign="top"><strong>Temperature Setting</strong></td>
<td align="center" valign="top">Digital display with push-button data entry</td>
</tr>
<tr>
<td valign="top"><strong>Set-Point Resolution</strong></td>
<td align="center" valign="top">0.01 °C; high-resolution mode, 0.00018 °C</td>
</tr>
<tr>
<td valign="top"><strong>Display<br />
Temperature Resolution</strong></td>
<td align="center" valign="top">0.01 °C</td>
</tr>
<tr>
<td valign="top"><strong>Digital Setting Accuracy</strong></td>
<td align="center" valign="top">±1 °C</td>
</tr>
<tr>
<td valign="top"><strong>Digital Setting Repeatability</strong></td>
<td align="center" valign="top">±0.02 °C</td>
</tr>
<tr>
<td valign="top"><strong>Heaters</strong></td>
<td align="center" valign="top">350 and 1050 watts</td>
</tr>
<tr>
<td valign="top"><strong>Access Opening<br />
(call for custom openings)</strong></td>
<td align="center" valign="top">127 x 254 mm (5 x 10 in)</td>
</tr>
<tr>
<td valign="top"><strong>Depth</strong></td>
<td align="center" valign="top">305 mm (12 in)</td>
</tr>
<tr>
<td valign="top"><strong>Wetted Parts</strong></td>
<td align="center" valign="top">304 stainless steel</td>
</tr>
<tr>
<td valign="top"><strong>Power</strong></td>
<td align="center" valign="top">115 VAC (±10 %), 50/60 Hz, 10 A or 230 VAC (±10 %), 50/60 Hz, 5 A, specify</td>
</tr>
<tr>
<td valign="top"><strong>Volume</strong></td>
<td align="center" valign="top">27 liters (7.2 gallons)</td>
</tr>
<tr>
<td valign="top"><strong>Weight</strong></td>
<td align="center" valign="top">32 kg (70 lb.)</td>
</tr>
<tr>
<td valign="top"><strong>Size (HxWxD)</strong></td>
<td align="center" valign="top">648 x 406 x 508 mm<br />
(25.5 x 16 x 20 in)</td>
</tr>
<tr>
<td valign="top"><strong>Automation Package</strong></td>
<td align="center" valign="top">MetTemp II software and RS-232 computer interface are included for setting bath temperature via remote computer. For IEEE-488, add the 2001-IEEE.</td>
</tr>
<tr>
<td colspan="2"><sup>†</sup>External cooling required for operation below 40 °C. Cooling coils are built into the</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-6020-high-temperature-calibration-oil-bath/">Fluke 6020 High Temperature Calibration Oil Bath</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 7340/7380 Compact Temperature Calibration Baths</title>
		<link>https://koueitrading.com/global/product/fluke-7340-7380-compact-temperature-calibration-baths/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 03 Oct 2020 06:12:14 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125542</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 7340/7380 Features Stability and uniformity each better than ±0.008°C Metrology-level performance in lab-friendly sizes Convenient use on benchtops or on matching carts Specifications Specifications . 7340 7380 Range –40 °C to 150 °C –80 °C to 100 °C Stability ± 0.005 °C at –40 °C (ethanol) ± 0.005 °C at 25 [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-7340-7380-compact-temperature-calibration-baths/">Fluke 7340/7380 Compact Temperature Calibration Baths</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 7340/7380</p>
<h2>Features</h2>
<ul>
<li>Stability and uniformity each better than ±0.008°C</li>
<li>Metrology-level performance in lab-friendly sizes</li>
<li>Convenient use on benchtops or on matching carts</li>
</ul>
<h2><strong>Specifications</strong></h2>
<table class="table" border="1" cellspacing="0" cellpadding="5">
<tbody>
<tr>
<td colspan="5" bgcolor="#e9eff4"><strong>Specifications</strong></td>
</tr>
<tr>
<td width="20%"><span style="color: #fffff0;">.</span></td>
<td align="center" width="20%"><strong>7340</strong></td>
<td align="center" width="20%"><strong>7380</strong></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Range</strong></td>
<td style="text-align: center;" align="center" valign="top">–40 °C to 150 °C</td>
<td style="text-align: center;" align="center" valign="top">–80 °C to 100 °C</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Stability</strong></td>
<td align="center" valign="top">± 0.005 °C at<br />
–40 °C (ethanol)<br />
± 0.005 °C at<br />
25 °C (water)<br />
± 0.007 °C at<br />
150 °C (oil 5012)</td>
<td align="center" valign="top">± 0.006 °C at<br />
–80 °C (ethanol)<br />
± 0.010 °C at<br />
0 °C (ethanol)<br />
± 0.010 °C at<br />
100 °C (oil 5012)</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Uniformity</strong></td>
<td style="text-align: center;" align="center" valign="top">±0.006 °C at<br />
–40 °C (ethanol)<br />
±0.005 °C at<br />
2 5 °C (water)<br />
±0.010 °C at<br />
150 °C (oil 5012)</td>
<td style="text-align: center;" align="center" valign="top">±0.008 °C at<br />
–80 °C (ethanol)<br />
±0.012 °C<br />
at 0 °C (ethanol)<br />
±0.012 °C at<br />
100 °C<br />
(oil 5012)</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Heating Time<sup>†</sup></strong></td>
<td align="center" valign="top">60 minutes,<br />
from 25°C<br />
to 150°C<br />
(oil 5012)</td>
<td align="center" valign="top">25 minutes,<br />
from 25 °C<br />
to 100 °C<br />
(oil 5010)</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Cooling Time</strong></td>
<td style="text-align: center;" align="center" valign="top">110 minutes,<br />
from 25°C<br />
to –40°C<br />
(ethanol)</td>
<td style="text-align: center;" align="center" valign="top">130 minutes,<br />
from 25 °C<br />
to –80 °C<br />
(ethanol)</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Stabilization Time</strong></td>
<td colspan="2" align="center" valign="top">15–20 minutes</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Temperature Setting</strong></td>
<td style="text-align: center;" colspan="2" align="center" valign="top">Digital display with push-button data entry</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Set-Point Resolution</strong></td>
<td align="center" valign="top">0.01°; 0.00018° in high-resolution mode</td>
<td align="center" valign="top">0.01°</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Display Resolution</strong></td>
<td style="text-align: center;" colspan="2" align="center" valign="top">0.01 °</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Digital Setting Accuracy</strong></td>
<td colspan="2" align="center" valign="top">± 0.5 °C</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Digital Setting Repeatability</strong></td>
<td style="text-align: center;" colspan="2" align="center" valign="top">± 0.01 °C</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Access Opening</strong></td>
<td align="center" valign="top">94 x 172 mm (3.7 x 6.8 in)</td>
<td align="center" valign="top">86 x 114 mm (3.25 x 4.5 in)</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Working Area</strong></td>
<td style="text-align: center;" align="center" valign="top">81 x 133 mm (3.2 x 5.25 in)</td>
<td style="text-align: center;" align="center" valign="top">86 x 114 mm (3 x 4 in)</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Depth</strong></td>
<td align="center" valign="top">234 mm (9.25 in)</td>
<td align="center" valign="top">178 mm (7 in)</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Wetted Parts</strong></td>
<td style="text-align: center;" colspan="2" align="center" valign="top">304 stainless steel</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Power</strong></td>
<td align="center" valign="top">115 V ac (±10 %), 60 Hz, 15 A or 230 V ac<br />
(±10 %), 50 Hz, 8 A, specify, 1400 VA</td>
<td align="center" valign="top">115 V ac (±10 %) 60 Hz, 16 A or 230 V ac<br />
(±10 %),50 Hz, 8 A, specify</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Volume</strong></td>
<td style="text-align: center;" align="center" valign="top">9.2 liters (2.4 gal)</td>
<td style="text-align: center;" align="center" valign="top">4 liters (1 gal)</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Size (WxDxH)</strong></td>
<td align="center" valign="top">305 x 622 x 584 mm (12 x 24.5 x 23 in) off cart; 305 x 622 x 819 mm (12 x 24.5 x 32.25 in) on cart</td>
<td align="center" valign="top">305 x 610 x 762 mm (12 x 24 x 30 in)</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Weight</strong></td>
<td style="text-align: center;" align="center" valign="top">35.4 kg (78 lb)</td>
<td style="text-align: center;" align="center" valign="top">52 kg (115 lb)</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Automation</strong></td>
<td colspan="2" valign="top">Use the 1586A Super-DAQ to automate temperature sensor calibration</td>
</tr>
<tr>
<td colspan="3">†Rated at nominal 115 V (or optional 230 V)</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-7340-7380-compact-temperature-calibration-baths/">Fluke 7340/7380 Compact Temperature Calibration Baths</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 7312 Triple Point of Water Maintenance Bath</title>
		<link>https://koueitrading.com/global/product/fluke-7312-triple-point-of-water-maintenance-bath/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 03 Oct 2020 03:54:20 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125489</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 7312 Features Maintains TPW cells for up to six weeks Optional immersion freezer for simple cell freezing Independent cutout circuit protects cells from breaking General Specifications Range –5 °C to 110 °C Stability ±0.001 °C at 0 °C (alcohol-water mix) ±0.004 °C at 30 °C (alcohol-water mix) Uniformity ±0.003 °C at [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-7312-triple-point-of-water-maintenance-bath/">Fluke 7312 Triple Point of Water Maintenance Bath</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 7312</p>
<h2>Features</h2>
<ul>
<li>Maintains TPW cells for up to six weeks</li>
<li>Optional immersion freezer for simple cell freezing</li>
<li>Independent cutout circuit protects cells from breaking</li>
</ul>
<table class="table" border="1" cellspacing="0" cellpadding="5">
<tbody>
<tr bgcolor="#e9eff4">
<td colspan="2">
<h2>General Specifications</h2>
</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Range</strong></td>
<td style="text-align: center;">–5 °C to 110 °C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Stability</strong></td>
<td style="text-align: center;">±0.001 °C at 0 °C (alcohol-water mix)<br />
±0.004 °C at 30 °C (alcohol-water mix)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Uniformity</strong></td>
<td style="text-align: center;">±0.003 °C at 0 °C (alcohol-water mix)<br />
±0.006 °C at 30 °C (alcohol-water mix)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>TPW Duration</strong></td>
<td style="text-align: center;">Six weeks, typical (assumes correctly formed ice mantle)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Set-Point Accuracy</strong></td>
<td style="text-align: center;">±0.05 °C at 0 °C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Set-Point Repeatability</strong></td>
<td style="text-align: center;">±0.01 °C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Display Resolution</strong></td>
<td style="text-align: center;">±0.01 °C</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Set-Point Resolution</strong></td>
<td style="text-align: center;">±0.002 °C; 0.00003 °C in high-resolution mode</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Access Opening</strong></td>
<td style="text-align: center;">121 x 97 mm (4.75 x 3.8 in)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Immersion Depth</strong></td>
<td style="text-align: center;">496 mm (19.5 in)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Volume</strong></td>
<td style="text-align: center;">19 liters (5 gallons)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Communications</strong></td>
<td style="text-align: center;">RS-232 included</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Power</strong></td>
<td style="text-align: center;">115 VAC (±10 %), 60 Hz or 230 VAC (±10 %), 50 Hz, specify</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Size (HxWxD)</strong></td>
<td style="text-align: center;">819 x 305 x 622 mm (12 x 24.5 x 32.25 in)</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Weight</strong></td>
<td style="text-align: center;">34 kg (75 lb.)</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-7312-triple-point-of-water-maintenance-bath/">Fluke 7312 Triple Point of Water Maintenance Bath</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 7008/7037/7012/7011 Refrigerated Temperature Calibration Baths</title>
		<link>https://koueitrading.com/global/product/fluke-7008-7037-7012-7011-refrigerated-temperature-calibration-baths/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 03 Oct 2020 03:40:43 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125421</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 7008/7037/7012/7011 Features Stability to ±0.0007 °C Best digital temperature controller available “Super Tweak” function provides set-point resolution to 0.00003 °C Excellent for maintaining fixed-point cells Specifications Specifications Model 7008 7037 7012 7011 Range –5 °C to 110 °C –40 °C to 110 °C –10 °C to 110 °C Stability ±0.0007 °C [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-7008-7037-7012-7011-refrigerated-temperature-calibration-baths/">Fluke 7008/7037/7012/7011 Refrigerated Temperature Calibration Baths</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 7008/7037/7012/7011</p>
<h2>Features</h2>
<ul>
<li>Stability to ±0.0007 °C</li>
<li>Best digital temperature controller available</li>
<li>“Super Tweak” function provides set-point resolution to 0.00003 °C</li>
<li>Excellent for maintaining fixed-point cells</li>
</ul>
<p><img loading="lazy" decoding="async" class="alignleft wp-image-125484 size-full" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-104218-1.png" alt="7008/7037/7012/7011" width="294" height="231" /> <img loading="lazy" decoding="async" class="alignnone wp-image-125485" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-104213-1.png" alt="7008/7037/7012/7011" width="331" height="255" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-104213-1.png 349w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-104213-1-300x231.png 300w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-104213-1-248x190.png 248w" sizes="auto, (max-width: 331px) 100vw, 331px" /></p>
<h2>Specifications</h2>
<table class="table" border="1" cellspacing="0" cellpadding="4">
<tbody>
<tr>
<td class="bodybold" style="text-align: center;" colspan="5" bgcolor="#dde6ed">Specifications</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b>Model</b></td>
<td style="text-align: center;" valign="top">
<div align="center"><b>7008</b></div>
</td>
<td style="text-align: center;" valign="top">
<div align="center"><b>7037</b></div>
</td>
<td style="text-align: center;" valign="top">
<div align="center"><b>7012</b></div>
</td>
<td style="text-align: center;" valign="top">
<div align="center"><b>7011</b></div>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b>Range</b></td>
<td style="text-align: center;" valign="top">
<div align="center">–5 °C to 110 °C</div>
</td>
<td style="text-align: center;" valign="top">
<div align="center">–40 °C to 110 °C</div>
</td>
<td colspan="2" valign="top">
<div style="text-align: center;" align="center">–10 °C to 110 °C</div>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b>Stability</b></td>
<td valign="top">
<div align="center">±0.0007 °C at 25 °C (water)<br />
±0.001 °C at 25 °C (mineral oil)</div>
</td>
<td valign="top">
<div align="center">±0.002 °C at –40 °C (ethanol)<br />
±0.0015 °C at 25 °C (water)<br />
±0.003 °C at 100 °C (oil 5012)</div>
</td>
<td colspan="2" valign="top">
<div align="center">±0.0008 °C at 0 °C (ethanol)<br />
±0.0008 °C at 25 °C (water)<br />
±0.003 °C at 100 °C (oil 5012)</div>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b>Uniformity</b></td>
<td valign="top">
<div align="center">±0.003 °C at 25 °C (water)<br />
±0.004 °C at 25 °C (mineral oil)</div>
</td>
<td valign="top">
<div align="center">±0.004 °C at –40 °C (ethanol)<br />
±0.002 °C at 25 °C (water)<br />
±0.004 °C at 100 °C (oil 5012)</div>
</td>
<td colspan="2" valign="top">
<div align="center">±0.003 °C at 0 °C (ethanol)<br />
±0.002 °C at 25 °C (water)<br />
±0.004 °C at 100 °C (oil 5012)</div>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b>Temperature Setting</b></td>
<td colspan="4" valign="top">
<div align="center">Digital display with push-button data entry</div>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b>Set-Point Resolution</b></td>
<td valign="top">
<div align="center">0.002 °C; high-resolution mode, 0.00003 °C</div>
</td>
<td valign="top">
<div align="center">0.01 °C; high-resolution mode, 0.00007 °C</div>
</td>
<td colspan="2" valign="top">
<div align="center">0.002 °C; high-resolution mode, 0.00003 °C</div>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b>Display Resolution</b></td>
<td colspan="4" valign="top">
<div align="center">0.01 °C</div>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b>Digital Setting Accuracy</b></td>
<td style="text-align: center;" colspan="4" valign="top">
<div align="center">±1 °C</div>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b>Digital Setting Repeatability</b></td>
<td colspan="2" valign="top">
<div align="center">±0.01 °C</div>
</td>
<td colspan="2" valign="top">
<div align="center">±0.005 °C</div>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b>Heaters</b></td>
<td style="text-align: center;" colspan="4" valign="top">
<div align="center">500 and 1000 Watts</div>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b>Access Opening (call for customs)</b></td>
<td valign="top">
<div align="center">324 x 184 mm(12.75 x 7.25 in)</div>
</td>
<td colspan="2" valign="top">
<div align="center">162 x 292 mm(6.38 x 11.5 in)</div>
</td>
<td valign="top">
<div align="center">127 x 254 mm(5 x 10 in)</div>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b>Depth</b></td>
<td style="text-align: center;" valign="top">
<div align="center">331 mm (13 in)</div>
</td>
<td style="text-align: center;" colspan="2" valign="top">
<div align="center">457 mm (18 in)</div>
</td>
<td style="text-align: center;" valign="top">
<div align="center">305 mm (12 in)</div>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b>Wetted Parts</b></td>
<td colspan="4" valign="top">
<div align="center">304 Stainless Steel</div>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b>Power</b></td>
<td style="text-align: center;" valign="top">
<div align="center">115 VAC (±10 %), 60 Hz, 14 A or 230 VAC, 50 or 60 Hz, 8 A, specify</div>
</td>
<td style="text-align: center;" valign="top">
<div align="center">115 VAC (±10 %), 60 Hz, 16 A or 230 VAC (±10 %), 50 or 60 Hz, 9 A (specify voltage and frequency)</div>
</td>
<td style="text-align: center;" colspan="2" valign="top">
<div align="center">115 VAC (±10 %), 60 Hz, 14 A or 230 VAC (±10 %), 50 Hz, 7 A, specify</div>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b>Volume</b></td>
<td valign="top">
<div align="center">42 liters (11.2 gal)</div>
</td>
<td colspan="2" valign="top">
<div align="center">42 liters (11.2 gal)</div>
</td>
<td valign="top">
<div align="center">27 liters (7.2 gal)</div>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b>Weight</b></td>
<td style="text-align: center;" valign="top">
<div align="center">61 kg (135 lb)</div>
</td>
<td style="text-align: center;" colspan="2" valign="top">
<div align="center">68 kg (150 lb)</div>
</td>
<td style="text-align: center;" valign="top">
<div align="center">56.7 kg (125 lb)</div>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b>Size</b></td>
<td valign="top">
<div align="center">610 x 775 x 483 mm (24 x 30.5 x 19 in)</div>
</td>
<td valign="top">
<div align="center">775 x 768 x 483 mm (30.5 x 30.25 x 19 in)</div>
</td>
<td valign="top">
<div align="center">762 x 686 x 401 mm (30 x 27 x 15.8 in)</div>
</td>
<td valign="top">
<div align="center">559 x 686 x 401 mm (22 x 27 x 15.8 in)</div>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><b>Automation</b></td>
<td colspan="4" valign="top">Use the 1586A Super-DAQ to automate temperature sensor calibration</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/fluke-7008-7037-7012-7011-refrigerated-temperature-calibration-baths/">Fluke 7008/7037/7012/7011 Refrigerated Temperature Calibration Baths</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke 6331/7321/7341/7381 Deep-Well Compact Baths</title>
		<link>https://koueitrading.com/global/product/fluke-6331-7321-7341-7381-deep-well-compact-baths/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 03 Oct 2020 02:09:44 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125392</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: 6331/7321/7341/7381 Features 457 mm (18 in) of depth with just 15.9 liters (4.2 gal) of fluid Perfect for liquid-in-glass thermometers with optional LIG kit Fast, quiet, compact (yet deep!), and economical Specifications Specifications Range 6331  35 °C to 300 °C 7321  –20 °C to 150 °C 7341  –45 °C to 150 [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-6331-7321-7341-7381-deep-well-compact-baths/">Fluke 6331/7321/7341/7381 Deep-Well Compact Baths</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: 6331/7321/7341/7381</p>
<h2>Features</h2>
<ul>
<li>457 mm (18 in) of depth with just 15.9 liters (4.2 gal) of fluid</li>
<li>Perfect for liquid-in-glass thermometers with optional LIG kit</li>
<li>Fast, quiet, compact (yet deep!), and economical</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-125417" src="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-103411.png" alt="6331/7321/7341/7381" width="457" height="358" srcset="https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-103411.png 840w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-103411-300x235.png 300w, https://koueitrading.com/global/wp-content/uploads/2024/10/Screenshot-2024-10-03-103411-768x602.png 768w" sizes="auto, (max-width: 457px) 100vw, 457px" /></p>
<h2>Specifications</h2>
<div id="quicktabs-tabs-wrapper"></div>
<div id="quicktabs_container_product_details" class="quicktabs_main quicktabs-style-nostyle">
<div id="quicktabs_tabpage_product_details_2" class="quicktabs_tabpage">
<div class="view view-product-details view-id-product_details view-display-id-block_1 view-dom-id-4 view-product-details view-id-product_details view-display-id-block_1 view-dom-id-4">
<div class="view-content">
<div class="views-row views-row-1 views-row-odd views-row-first views-row-last">
<div class="views-field-field-product-specifications-value">
<table width="208">
<tbody>
<tr>
<td style="text-align: center;" colspan="3" width="208">Specifications</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="4" width="78">Range</td>
<td style="text-align: center;" width="51">6331</td>
<td style="text-align: center;" width="79"> 35 °C to 300 °C</td>
</tr>
<tr>
<td style="text-align: center;" width="51">7321</td>
<td style="text-align: center;" width="79"> –20 °C to 150 °C</td>
</tr>
<tr>
<td style="text-align: center;" width="51">7341</td>
<td style="text-align: center;" width="79"> –45 °C to 150 °C</td>
</tr>
<tr>
<td style="text-align: center;" width="51">7381</td>
<td style="text-align: center;" width="79"> –80 °C to 110 °C</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="12" width="78">Stability</td>
<td style="text-align: center;" rowspan="3" width="51">6331</td>
<td style="text-align: center;" width="79">±0.007 °C at 100 °C (oil 5012)</td>
</tr>
<tr>
<td style="text-align: center;" width="79">±0.010 °C at 200 °C (oil 5017)</td>
</tr>
<tr>
<td style="text-align: center;" width="79">±0.015 °C at 300 °C (oil 5017)</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="3" width="51">7321</td>
<td style="text-align: center;" width="79">±0.005°C at –20°C (ethanol)</td>
</tr>
<tr>
<td style="text-align: center;" width="79">±0.005°C at 25°C (water)</td>
</tr>
<tr>
<td style="text-align: center;" width="79">±0.007°C at 150°C (oil 5012)</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="3" width="51">7341</td>
<td style="text-align: center;" width="79"> ±0.005°C at –45°C (ethanol)</td>
</tr>
<tr>
<td style="text-align: center;" width="79">±0.005°C at 25°C (water)</td>
</tr>
<tr>
<td style="text-align: center;" width="79">±0.007°C at 150°C (oil 5012)</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="3" width="51">7381</td>
<td style="text-align: center;" width="79">±0.006°C at –80°C (ethanol)</td>
</tr>
<tr>
<td style="text-align: center;" width="79">±0.005°C at 0°C (ethanol)</td>
</tr>
<tr>
<td style="text-align: center;" width="79">±0.005°C at 100°C (oil 5012)</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="12" width="78">Uniformity</td>
<td style="text-align: center;" rowspan="3" width="51">6331</td>
<td style="text-align: center;" width="79">±0.007 °C at 100 °C (oil 5012)</td>
</tr>
<tr>
<td style="text-align: center;" width="79">±0.017 °C at 200 °C (oil 5017)</td>
</tr>
<tr>
<td style="text-align: center;" width="79">±0.025 °C at 300 °C (oil 5017)</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="3" width="51">7321</td>
<td style="text-align: center;" width="79">±0.007 °C at –20 °C (ethanol)</td>
</tr>
<tr>
<td style="text-align: center;" width="79">±0.00 7 °C at 2 5°C (water)</td>
</tr>
<tr>
<td style="text-align: center;" width="79">±0.010°C at 150 °C (oil 5012)</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="3" width="51">7341</td>
<td style="text-align: center;" width="79">±0.007 °C at –45 °C (ethanol)</td>
</tr>
<tr>
<td style="text-align: center;" width="79">±0.007 °C at 25 °C (water)</td>
</tr>
<tr>
<td style="text-align: center;" width="79">±0.010 °C at 150 °C (oil 5012)</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="3" width="51">7381</td>
<td style="text-align: center;" width="79">±0.007 °C at –80 °C (ethanol)</td>
</tr>
<tr>
<td style="text-align: center;" width="79">±0.007 °C at 0 °C (ethanol)</td>
</tr>
<tr>
<td style="text-align: center;" width="79">±0.007 °C at 100 °C (oil 5012)</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="4" width="78">Heating Time†</td>
<td style="text-align: center;" width="51">6331</td>
<td style="text-align: center;" width="79"> 130 minutes, from 40 °C to 300 °C (oil 5017)</td>
</tr>
<tr>
<td style="text-align: center;" width="51">7321</td>
<td style="text-align: center;" width="79"> 120 minutes, from 25 °C to 150 °C (oil 5012)</td>
</tr>
<tr>
<td style="text-align: center;" width="51">7341</td>
<td style="text-align: center;" width="79"> 120 minutes, from 25 °C to 150 °C (oil 5012)</td>
</tr>
<tr>
<td style="text-align: center;" width="51">7381</td>
<td style="text-align: center;" width="79"> 60 minutes, from 25 °C to 100 °C (oil 5012)</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="4" width="78">Cooling Time†</td>
<td style="text-align: center;" width="51">6331</td>
<td style="text-align: center;" width="79"> 14 hours, from 300 °C to 100 °C (oil 5017)</td>
</tr>
<tr>
<td style="text-align: center;" width="51">7321</td>
<td style="text-align: center;" width="79"> 110 minutes, from 25 °C to –20 °C (ethanol)</td>
</tr>
<tr>
<td style="text-align: center;" width="51">7341</td>
<td style="text-align: center;" width="79"> 130 minutes, from 25°C to –45°C (ethanol)</td>
</tr>
<tr>
<td style="text-align: center;" width="51">7381</td>
<td style="text-align: center;" width="79"> 210 minutes, from 25 °C to –80 °C (ethanol)</td>
</tr>
<tr>
<td style="text-align: center;" width="78">Stabilization Time</td>
<td style="text-align: center;" width="51"></td>
<td style="text-align: center;" width="79"> 15–20 minutes</td>
</tr>
<tr>
<td style="text-align: center;" width="78">Temperature Setting</td>
<td style="text-align: center;" width="51"></td>
<td style="text-align: center;" width="79"> Digital display with push-button data entry</td>
</tr>
<tr>
<td style="text-align: center;" width="78">Set-Point Resolution</td>
<td style="text-align: center;" width="51"></td>
<td style="text-align: center;" width="79"> 0.01°; 0.00018° in high-resolution mode</td>
</tr>
<tr>
<td style="text-align: center;" width="78">Display Resolution</td>
<td style="text-align: center;" width="51"></td>
<td style="text-align: center;" width="79"> 0.01°</td>
</tr>
<tr>
<td style="text-align: center;" width="78">Digital Setting Accuracy</td>
<td style="text-align: center;" width="51"></td>
<td style="text-align: center;" width="79"> ±1°C</td>
</tr>
<tr>
<td style="text-align: center;" width="78">Digital Setting Repeatability</td>
<td style="text-align: center;" width="51"></td>
<td style="text-align: center;" width="79"> ±0.01°C</td>
</tr>
<tr>
<td style="text-align: center;" width="78">Access Opening</td>
<td style="text-align: center;" width="51"></td>
<td style="text-align: center;" width="79"> 120 x 172 mm (4.7 x 6.8 in)</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="2" width="78">Depth</td>
<td style="text-align: center;" width="51"></td>
<td style="text-align: center;" width="79"> 457 mm (18 in) without Liquid-in-Glass Thermometer Cal Kit</td>
</tr>
<tr>
<td style="text-align: center;" width="51"></td>
<td style="text-align: center;" width="79"> 482 mm (19 in) with Liquid-in-Glass Thermometer Cal Kit</td>
</tr>
<tr>
<td style="text-align: center;" width="78">Wetted Parts</td>
<td style="text-align: center;" width="51"></td>
<td style="text-align: center;" width="79"> 304 stainless steel</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="7" width="78">Power†</td>
<td style="text-align: center;" rowspan="2" width="51">6331</td>
<td style="text-align: center;" width="79">115 VAC (±10 %), 50/60 Hz, 14.8 A or</td>
</tr>
<tr>
<td style="text-align: center;" width="79">230 VAC (±10 %), 50/60 Hz, 7.4 A, specify</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="2" width="51">7321</td>
<td style="text-align: center;" width="79">115 VAC (±10 %), 60 Hz, 14 A or</td>
</tr>
<tr>
<td style="text-align: center;" width="79">230 VAC (±10 %), 50 Hz, 7 A, specify</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="2" width="51">7341</td>
<td style="text-align: center;" width="79">115 VAC (±10 %), 60 Hz, 16 A or</td>
</tr>
<tr>
<td style="text-align: center;" width="79">230 VAC (±10 %), 50 Hz, 8 A, specify</td>
</tr>
<tr>
<td style="text-align: center;" width="51">7381</td>
<td style="text-align: center;" width="79">230 VAC (±10 %), 50 or 60 Hz, specify, 10 A</td>
</tr>
<tr>
<td style="text-align: center;" width="78">Volume</td>
<td style="text-align: center;" width="51"></td>
<td style="text-align: center;" width="79">15.9 liters (4.2 gal)</td>
</tr>
<tr>
<td style="text-align: center;" width="78">Size (HxWxD)</td>
<td width="51"></td>
<td style="text-align: center;" width="79">1067 x 356 x 788 mm (940 mm from floor to tank access opening) [42 x 14 x 31 in (37 in from floor to tank access opening)]</td>
</tr>
<tr>
<td style="text-align: center;" rowspan="4" width="78">Weight</td>
<td style="text-align: center;" width="51">6331</td>
<td style="text-align: center;" width="79"> 41 kg (90 lb.)</td>
</tr>
<tr>
<td style="text-align: center;" width="51">7321</td>
<td style="text-align: center;" width="79"> 62 kg (137 lb.)</td>
</tr>
<tr>
<td style="text-align: center;" width="51">7341</td>
<td style="text-align: center;" width="79"> 68 kg (150 lb.)</td>
</tr>
<tr>
<td style="text-align: center;" width="51">7381</td>
<td style="text-align: center;" width="79"> 91 kg (200 lb.)</td>
</tr>
<tr>
<td style="text-align: center;" width="78">Automation</td>
<td style="text-align: center;" width="51"></td>
<td style="text-align: center;" width="79"> Use the 1586A Super-DAQ to automate temperature sensor calibration</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>The post <a href="https://koueitrading.com/global/product/fluke-6331-7321-7341-7381-deep-well-compact-baths/">Fluke 6331/7321/7341/7381 Deep-Well Compact Baths</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke Mini Fixed-Point Cells</title>
		<link>https://koueitrading.com/global/product/fluke-mini-fixed-point-cells/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 03 Oct 2020 01:58:12 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125389</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Product name: Mini Fixed-Point Cells Features Lower uncertainties than comparison calibrations All ITS-90 fixed points from TPW to copper Reduced equipment and annual recalibration costs Specifications Model Number Fixed Point Temperature (°C) Outside Diameter Inside Diameter Total Cell Height Immersion Depth1 Cell Only2 Simple Realization2 5901B-G Water T.P. 0.01 30 mm 8 [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-mini-fixed-point-cells/">Fluke Mini Fixed-Point Cells</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Product name: Mini Fixed-Point Cells</p>
<h2>Features</h2>
<ul>
<li>Lower uncertainties than comparison calibrations</li>
<li>All ITS-90 fixed points from TPW to copper</li>
<li>Reduced equipment and annual recalibration costs</li>
</ul>
<h2>Specifications</h2>
<table>
<tbody>
<tr>
<th>Model Number</th>
<th>Fixed Point</th>
<th>Temperature (°C)</th>
<th>Outside Diameter</th>
<th>Inside Diameter</th>
<th>Total Cell Height</th>
<th>Immersion Depth<sup>1</sup></th>
<th>Cell Only<sup>2</sup></th>
<th>Simple Realization<sup>2</sup></th>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">5901B-G</td>
<td style="text-align: center;">Water T.P.</td>
<td style="text-align: center;">0.01</td>
<td style="text-align: center;">30 mm</td>
<td style="text-align: center;">8 mm</td>
<td style="text-align: center;">170 mm</td>
<td style="text-align: center;">117 mm</td>
<td style="text-align: center;">0.2</td>
<td style="text-align: center;">0.5</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">5914A</td>
<td style="text-align: center;">Indium F.P.</td>
<td style="text-align: center;">156.5985</td>
<td style="text-align: center;">43 mm</td>
<td style="text-align: center;">8 mm</td>
<td style="text-align: center;">214 mm</td>
<td style="text-align: center;">140 mm</td>
<td style="text-align: center;">1.0</td>
<td style="text-align: center;">2.0</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">5915A</td>
<td style="text-align: center;">Tin F.P.</td>
<td style="text-align: center;">231.928</td>
<td style="text-align: center;">43 mm</td>
<td style="text-align: center;">8 mm</td>
<td style="text-align: center;">214 mm</td>
<td style="text-align: center;">140 mm</td>
<td style="text-align: center;">1.4</td>
<td style="text-align: center;">3.0</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">5916A</td>
<td style="text-align: center;">Zinc F.P.</td>
<td style="text-align: center;">419.527</td>
<td style="text-align: center;">43 mm</td>
<td style="text-align: center;">8 mm</td>
<td style="text-align: center;">214 mm</td>
<td style="text-align: center;">140 mm</td>
<td style="text-align: center;">1.6</td>
<td style="text-align: center;">4.0</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">5917A</td>
<td style="text-align: center;">Aluminum F.P.</td>
<td style="text-align: center;">660.323</td>
<td style="text-align: center;">43 mm</td>
<td style="text-align: center;">8 mm</td>
<td style="text-align: center;">214 mm</td>
<td style="text-align: center;">140 mm</td>
<td style="text-align: center;">4.0</td>
<td style="text-align: center;">10.0</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">5918A</td>
<td style="text-align: center;">Silver F.P.</td>
<td style="text-align: center;">961.78</td>
<td style="text-align: center;">43 mm</td>
<td style="text-align: center;">8 mm</td>
<td style="text-align: center;">214 mm</td>
<td style="text-align: center;">140 mm</td>
<td style="text-align: center;">7.0</td>
<td style="text-align: center;">n/a</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">5919A</td>
<td style="text-align: center;">Copper F.P.</td>
<td style="text-align: center;">1084.62</td>
<td style="text-align: center;">43 mm</td>
<td style="text-align: center;">8 mm</td>
<td style="text-align: center;">214 mm</td>
<td style="text-align: center;">140 mm</td>
<td style="text-align: center;">15.0</td>
<td style="text-align: center;">n/a</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">5944</td>
<td style="text-align: center;">Indium F.P.</td>
<td style="text-align: center;">156.5985</td>
<td style="text-align: center;">41.3 mm</td>
<td style="text-align: center;">7.8 mm</td>
<td style="text-align: center;">222 mm</td>
<td style="text-align: center;">156 mm</td>
<td style="text-align: center;">0.7</td>
<td style="text-align: center;">1.4</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">5945</td>
<td style="text-align: center;">Tin F.P.</td>
<td style="text-align: center;">231.928</td>
<td style="text-align: center;">41.3 mm</td>
<td style="text-align: center;">7.8 mm</td>
<td style="text-align: center;">222 mm</td>
<td style="text-align: center;">156 mm</td>
<td style="text-align: center;">0.8</td>
<td style="text-align: center;">1.6</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">5946</td>
<td style="text-align: center;">Zinc F.P.</td>
<td style="text-align: center;">419.527</td>
<td style="text-align: center;">41.3 mm</td>
<td style="text-align: center;">7.8 mm</td>
<td style="text-align: center;">222 mm</td>
<td style="text-align: center;">156 mm</td>
<td style="text-align: center;">1.0</td>
<td style="text-align: center;">2.0</td>
</tr>
<tr>
<td class="PrdSpecItem" style="text-align: center;">5947</td>
<td style="text-align: center;">Aluminum F.P.</td>
<td style="text-align: center;">660.323</td>
<td style="text-align: center;">41.3 mm</td>
<td style="text-align: center;">7.8 mm</td>
<td style="text-align: center;">222 mm</td>
<td style="text-align: center;">156 mm</td>
<td style="text-align: center;">2.0</td>
<td style="text-align: center;">4.0</td>
</tr>
<tr>
<td colspan="9">Uncertainty (mK) k=2</p>
<p><sup>1</sup> Distance from the bottom of the central well to the surface of the pure metal.</p>
<p><sup>2</sup> &#8220;Cell Only&#8221; refers to the expanded uncertainty of the cell when realized by traditional methods and maintained using traditional maintenance devices. &#8220;Simple Realization&#8221; refers to the expanded uncertainty of the cell when realized using practical methods (melting points instead of freezing points or slush ice instead of an ice mantle, for example) and maintained using Hart’s 9210 and 9260 mini cell maintenance apparatus.</td>
</tr>
</tbody>
</table>
<div></div>The post <a href="https://koueitrading.com/global/product/fluke-mini-fixed-point-cells/">Fluke Mini Fixed-Point Cells</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluke ITS-90 Fixed-Point Cells</title>
		<link>https://koueitrading.com/global/product/fluke-its-90-fixed-point-cells/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 03 Oct 2020 01:51:14 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=125387</guid>

					<description><![CDATA[<p>Manufacturer: Fluke Calibration Model: ITS-90 Features Best cell uncertainties commercially available Every ITS-90 fixed point available from argon to copper Plateaus last days (gallium for weeks and TPW for months) Manufactured and tested by Fluke Calibration’s primary standards scientists Specifications Model Fixed Point Style Assigned Value (°C) Outside Diameter Inside Diameter Total Outside Cell Height Depth‡ Cell [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/fluke-its-90-fixed-point-cells/">Fluke ITS-90 Fixed-Point Cells</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Fluke Calibration<br />
Model: ITS-90</p>
<h2>Features</h2>
<ul>
<li>Best cell uncertainties commercially available</li>
<li>Every ITS-90 fixed point available from argon to copper</li>
<li>Plateaus last days (gallium for weeks and TPW for months)</li>
<li>Manufactured and tested by Fluke Calibration’s primary standards scientists</li>
</ul>
<h2>Specifications</h2>
<table>
<tbody>
<tr>
<th>Model</th>
<th>Fixed Point</th>
<th>Style</th>
<th>Assigned Value (°C)</th>
<th>Outside Diameter</th>
<th>Inside Diameter</th>
<th>Total Outside Cell Height</th>
<th>Depth<sup>‡</sup></th>
<th>Cell Uncertainty (mK, k=2)</th>
<th>Certification (mK, k=2)<sup>†</sup></th>
</tr>
<tr>
<td style="text-align: center;">5900E</td>
<td style="text-align: center;">Mercury</td>
<td style="text-align: center;">Stainless Steel</td>
<td style="text-align: center;">–38.8344</td>
<td style="text-align: center;">31 mm</td>
<td style="text-align: center;">8.2 mm</td>
<td style="text-align: center;">470 mm</td>
<td style="text-align: center;">200 mm</td>
<td style="text-align: center;">0.2</td>
<td style="text-align: center;">0.25</td>
</tr>
<tr>
<td style="text-align: center;">5904</td>
<td style="text-align: center;">Indium</td>
<td style="text-align: center;">Traditional Quartz Glass</td>
<td style="text-align: center;">156.5985</td>
<td style="text-align: center;">48 mm</td>
<td style="text-align: center;">8 mm</td>
<td style="text-align: center;">285 mm</td>
<td style="text-align: center;">195 mm</td>
<td style="text-align: center;">0.7</td>
<td style="text-align: center;">0.7</td>
</tr>
<tr>
<td style="text-align: center;">5905</td>
<td style="text-align: center;">Tin</td>
<td style="text-align: center;">Traditional Quartz Glass</td>
<td style="text-align: center;">231.928</td>
<td style="text-align: center;">48 mm</td>
<td style="text-align: center;">8 mm</td>
<td style="text-align: center;">285 mm</td>
<td style="text-align: center;">195 mm</td>
<td style="text-align: center;">0.5</td>
<td style="text-align: center;">0.8</td>
</tr>
<tr>
<td style="text-align: center;">5906</td>
<td style="text-align: center;">Zinc</td>
<td style="text-align: center;">Traditional Quartz Glass</td>
<td style="text-align: center;">419.527</td>
<td style="text-align: center;">48 mm</td>
<td style="text-align: center;">8 mm</td>
<td style="text-align: center;">285 mm</td>
<td style="text-align: center;">195 mm</td>
<td style="text-align: center;">0.9</td>
<td style="text-align: center;">1.0</td>
</tr>
<tr>
<td style="text-align: center;">5907</td>
<td style="text-align: center;">Aluminum</td>
<td style="text-align: center;">Traditional Quartz Glass</td>
<td style="text-align: center;">660.323</td>
<td style="text-align: center;">48 mm</td>
<td style="text-align: center;">8 mm</td>
<td style="text-align: center;">285 mm</td>
<td style="text-align: center;">195 mm</td>
<td style="text-align: center;">1.3</td>
<td style="text-align: center;">1.8</td>
</tr>
<tr>
<td style="text-align: center;">5908</td>
<td style="text-align: center;">Silver</td>
<td style="text-align: center;">Traditional Quartz Glass</td>
<td style="text-align: center;">961.78</td>
<td style="text-align: center;">48 mm</td>
<td style="text-align: center;">8 mm</td>
<td style="text-align: center;">285 mm</td>
<td style="text-align: center;">195 mm</td>
<td style="text-align: center;">2.4</td>
<td style="text-align: center;">4.5</td>
</tr>
<tr>
<td style="text-align: center;">5909</td>
<td style="text-align: center;">Copper</td>
<td style="text-align: center;">Traditional Quartz Glass</td>
<td style="text-align: center;">1084.62</td>
<td style="text-align: center;">48 mm</td>
<td style="text-align: center;">8 mm</td>
<td style="text-align: center;">285 mm</td>
<td style="text-align: center;">195 mm</td>
<td style="text-align: center;">10.1</td>
<td style="text-align: center;">12.0</td>
</tr>
<tr>
<td style="text-align: center;">5924</td>
<td style="text-align: center;">Indium</td>
<td style="text-align: center;">Open Quartz Glass</td>
<td style="text-align: center;">156.5985</td>
<td style="text-align: center;">50 mm</td>
<td style="text-align: center;">8 mm</td>
<td style="text-align: center;">596 mm</td>
<td style="text-align: center;">195 mm</td>
<td style="text-align: center;">0.7</td>
<td style="text-align: center;">0.7</td>
</tr>
<tr>
<td style="text-align: center;">5925</td>
<td style="text-align: center;">Tin</td>
<td style="text-align: center;">Open Quartz Glass</td>
<td style="text-align: center;">231.928</td>
<td style="text-align: center;">50 mm</td>
<td style="text-align: center;">8 mm</td>
<td style="text-align: center;">596 mm</td>
<td style="text-align: center;">195 mm</td>
<td style="text-align: center;">0.5</td>
<td style="text-align: center;">0.8</td>
</tr>
<tr>
<td style="text-align: center;">5926</td>
<td style="text-align: center;">Zinc</td>
<td style="text-align: center;">Open Quartz Glass</td>
<td style="text-align: center;">419.527</td>
<td style="text-align: center;">50 mm</td>
<td style="text-align: center;">8 mm</td>
<td style="text-align: center;">596 mm</td>
<td style="text-align: center;">195 mm</td>
<td style="text-align: center;">0.9</td>
<td style="text-align: center;">1.0</td>
</tr>
<tr>
<td style="text-align: center;">5927A-L</td>
<td style="text-align: center;">Aluminum</td>
<td style="text-align: center;">Open Quartz Glass (long)</td>
<td style="text-align: center;">660.323</td>
<td style="text-align: center;">50 mm</td>
<td style="text-align: center;">8 mm</td>
<td style="text-align: center;">696 mm</td>
<td style="text-align: center;">195 mm</td>
<td style="text-align: center;">1.3</td>
<td style="text-align: center;">1.8</td>
</tr>
<tr>
<td style="text-align: center;">5927A-S</td>
<td style="text-align: center;">Aluminum</td>
<td style="text-align: center;">Open Quartz Glass (short)</td>
<td style="text-align: center;">660.323</td>
<td style="text-align: center;">50 mm</td>
<td style="text-align: center;">8 mm</td>
<td style="text-align: center;">596 mm</td>
<td style="text-align: center;">195 mm</td>
<td style="text-align: center;">1.3</td>
<td style="text-align: center;">1.8</td>
</tr>
<tr>
<td style="text-align: center;">5928</td>
<td style="text-align: center;">Silver</td>
<td style="text-align: center;">Open Quartz Glass</td>
<td style="text-align: center;">961.78</td>
<td style="text-align: center;">50 mm</td>
<td style="text-align: center;">8 mm</td>
<td style="text-align: center;">696 mm</td>
<td style="text-align: center;">195 mm</td>
<td style="text-align: center;">2.4</td>
<td style="text-align: center;">4.5</td>
</tr>
<tr>
<td style="text-align: center;">5929</td>
<td style="text-align: center;">Copper</td>
<td style="text-align: center;">Open Quartz Glass</td>
<td style="text-align: center;">1084.62</td>
<td style="text-align: center;">50 mm</td>
<td style="text-align: center;">8 mm</td>
<td style="text-align: center;">696 mm</td>
<td style="text-align: center;">195 mm</td>
<td style="text-align: center;">10</td>
<td style="text-align: center;">12.0</td>
</tr>
<tr>
<td style="text-align: center;">5943</td>
<td style="text-align: center;">Gallium</td>
<td style="text-align: center;">Stainless Steel</td>
<td style="text-align: center;">29.7646</td>
<td style="text-align: center;">38.1 mm</td>
<td style="text-align: center;">8.2 mm</td>
<td style="text-align: center;">250 mm</td>
<td style="text-align: center;">168 mm</td>
<td style="text-align: center;">0.1</td>
<td style="text-align: center;">0.1</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>