	 
	 
	 
<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>KOKEN LTD. | Kouei Japan Trading | Get Quotation</title>
	<atom:link href="https://koueitrading.com/global/product-cat/koken-ltd/feed/" rel="self" type="application/rss+xml" />
	<link>https://koueitrading.com/global</link>
	<description>Purchase tools and equipments made in Japan</description>
	<lastBuildDate>Thu, 19 Mar 2026 04:05:32 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.5</generator>

<image>
	<url>https://koueitrading.com/global/wp-content/uploads/2018/01/cropped-KoueiVietnam-logo-32x32.png</url>
	<title>KOKEN LTD. | Kouei Japan Trading | Get Quotation</title>
	<link>https://koueitrading.com/global</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Koken BL-7005 Bresslink</title>
		<link>https://koueitrading.com/global/product/koken-bl-7005-bresslink/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 19 Mar 2020 03:46:43 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=193582</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: BL-7005 Breath-Link SeriesLightweight and High-Performance for Welding Operations BL-7005 Starting April 2022, for indoor metal welding operations, the use of high-efficiency protective masks appropriate for the measured welding fume concentration will be required. Higher welding fume concentrations will necessitate masks with a higher assigned protection factor.The BL-7005 is a high-end model [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-bl-7005-bresslink/">Koken BL-7005 Bresslink</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: BL-7005</p>
<p>Breath-Link Series<br data-start="89" data-end="92" />Lightweight and High-Performance for Welding Operations</p>
<h2>BL-7005</h2>
<p>Starting April 2022, for indoor metal welding operations, the use of high-efficiency protective masks appropriate for the measured welding fume concentration will be required. Higher welding fume concentrations will necessitate masks with a higher assigned protection factor.<br data-start="406" data-end="409" />The BL-7005 is a high-end model suitable for welding operations requiring a protection factor up to 33.</p>
<p data-start="63" data-end="149"><img fetchpriority="high" decoding="async" class="aligncenter wp-image-56286" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-08_101719-removebg-preview.png" alt="" width="306" height="313" />Sakai Model<br data-start="75" data-end="78" />BL-7005<br data-start="85" data-end="88" data-is-only-node="" />Includes battery and charger</p>
<p data-start="63" data-end="149">Lightest PL2 model in the domestic market *Note 1<br data-start="93" data-end="96" />Assigned Protection Factor: 33<br data-start="124" data-end="127" />Extended filter life *Note 2</p>
<p data-start="153" data-end="263">*Note 1: Among domestic PAPR (PL2 Model) products, released in June 2021 (based on company research).<br />
*Note 2: Compared to the BL-1005-02 model.</p>
<p data-start="153" data-end="263"><img decoding="async" class="aligncenter size-full wp-image-56287" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-08_101851-removebg-preview.png" alt="" width="200" height="179" /></p>
<p data-start="153" data-end="263">Sakai Model<br data-start="75" data-end="78" />BL-7005AL<br data-start="87" data-end="90" data-is-only-node="" />Includes battery and charger<br data-start="107" data-end="110" />Radiant heat reduction<br data-start="127" data-end="130" />Constructed with aluminum vapor deposition</p>
<p data-start="153" data-end="263">A high-end model has been added to the 1005 series, which is highly popular in the welding industry.</p>
<p data-start="153" data-end="263"><img decoding="async" class=" wp-image-193590 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-3-300x41.jpg" alt="" width="739" height="101" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-3-300x41.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-3-768x104.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-3.jpg 1024w" sizes="(max-width: 739px) 100vw, 739px" />Because it is an upgraded model based on the long-selling 1005 series, users transitioning to a powered air-purifying respirator can do so with confidence. (Sakai Model BL-7005)</p>
<h3 data-start="153" data-end="263"><strong>Sakai Model BL-7005</strong><br data-start="83" data-end="86" /><strong>The long-selling 1005 series known for &#8216;ease of use&#8217; has now evolved with higher &#8216;performance&#8217; and lighter weight.</strong></h3>
<h2 data-start="63" data-end="90"><strong data-start="63" data-end="90">5 Benefits of Breath-Link</strong></h2>
<p data-start="92" data-end="327">Based on Breath Synchronized Blower System (BSFS) technology, it delivers air during inhalation and stops blowing during exhalation. This reduces fan noise, provides safety and comfort, and lowers operating costs.</p>
<ol>
<li data-start="332" data-end="556"><strong data-start="332" data-end="363">Lightest PL2 model in the domestic market</strong> (approx. 290g)<br data-start="371" data-end="374" />With high fan efficiency reducing battery size requirements, the use of a compact battery combined with the facepiece results in a lightweight product that is easy to wear for long periods without feeling heavy.</li>
<li data-start="561" data-end="701"><strong data-start="561" data-end="605">Extended filter life via new fiber structure</strong><br data-start="605" data-end="608" />Compared to conventional filters, the new filter provides high collection efficiency (PL2) while allowing for longer continuous usage.</li>
<li data-start="706" data-end="773"><strong data-start="706" data-end="726">Long battery life</strong><br data-start="726" data-end="729" />Reduced fan noise operation helps minimize battery consumption.</li>
<li data-start="778" data-end="944"><strong data-start="778" data-end="798">Natural breathing</strong><br data-start="798" data-end="801" />Improves breathing dynamics during various tasks and reduces the discomfort of wearing a mask. It provides a natural breathing sensation as if not wearing a mask at least.</li>
<li data-start="949" data-end="1072"><strong data-start="949" data-end="964">High safety</strong><br data-start="964" data-end="967" />With a positive pressure design, it minimizes the ingress of dust and moisture into the facepiece, thereby increasing protective efficiency.</li>
</ol>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56289" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-102840.png" alt="" width="294" height="250" /></p>
<h2>Other Features</h2>
<ul>
<li data-start="11" data-end="117">Use with welding mask: Can be used together with a welding mask and is compatible with welding surfaces.</li>
<li data-start="120" data-end="209">Voice: Allows voice transmission inside the mask and enables communication with others.</li>
<li data-start="212" data-end="304">Fit check: Enables quick checking of the mask’s seal using the integrated fit-testing kit.</li>
<li data-start="307" data-end="405">Notification: Notifies the battery replacement time through an “airflow conditioning” indicator.</li>
<li data-start="408" data-end="499">Silicone: Made of durable silicone with high heat resistance, providing comfortable wear.</li>
<li data-start="502" data-end="633">Auto on/off: The fan automatically starts when wearing the mask and breathing in, and automatically stops when the mask is removed.</li>
</ul>
<p><img loading="lazy" decoding="async" class=" wp-image-193589 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-2-300x105.jpg" alt="" width="523" height="183" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-2-300x105.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-2-768x270.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-2.jpg 1024w" sizes="auto, (max-width: 523px) 100vw, 523px" /></p>
<h2>Performance and Specifications</h2>
<table>
<tbody>
<tr>
<th class="header-col" colspan="2"><strong>Model Name (Product Code)</strong></th>
<td class="data-cell" style="width: 30%;">BL-7005</td>
<td class="data-cell" style="width: 30%;">BL-7005AL</td>
</tr>
<tr>
<th class="header-col" colspan="2"><strong>National Assay Certificate</strong></th>
<td class="data-cell" colspan="2">No. TP122</td>
</tr>
<tr>
<th class="header-col" colspan="2"><strong>Head Harness</strong></th>
<td class="data-cell" colspan="2">SB/SA Type</td>
</tr>
<tr>
<th class="header-col" colspan="2"><strong>Applicable Filter</strong></th>
<td class="data-cell" colspan="2">Mighty Micron Filter for BL-7005</td>
</tr>
<tr>
<th class="header-col" rowspan="3"><strong>Classification</strong></th>
<th class="sub-header"><strong>Fan Performance</strong></th>
<td class="data-cell" colspan="2">Standard Airflow Type</td>
</tr>
<tr>
<th class="sub-header"><strong>Inward Leakage Performance</strong></th>
<td class="data-cell" colspan="2">Class A (Below 1.0%)</td>
</tr>
<tr>
<th class="sub-header"><strong>Filter Material Performance (Particle Collection Efficiency)</strong></th>
<td class="data-cell" colspan="2">PL2 (99.0% or higher)</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-bg text-left" colspan="2"><strong>Model Name (Product Code)</strong></th>
<td class="text-left">BL-7005</td>
<td class="text-left">BL-7005AL</td>
</tr>
<tr>
<th class="header-bg text-left" colspan="2"><strong>National Assay Certificate</strong></th>
<td class="text-left" colspan="2">No. TP122</td>
</tr>
<tr>
<th class="header-bg text-left" colspan="2"><strong>Head Harness</strong></th>
<td class="text-left" colspan="2">SB/SA Type</td>
</tr>
<tr>
<th class="header-bg text-left" colspan="2"><strong>Applicable Filter</strong></th>
<td class="text-left" colspan="2">Mighty Micron Filter for BL-7005</td>
</tr>
<tr>
<th class="header-bg text-left col-header-main" rowspan="3"><strong>Classification</strong></th>
<th class="header-bg text-left col-header-sub"><strong>Fan Performance</strong></th>
<td class="text-left" colspan="2">Standard Airflow Type</td>
</tr>
<tr>
<th class="header-bg text-left"><strong>Inward Leakage Performance</strong></th>
<td class="text-left" colspan="2">Class A (Below 1.0%)</td>
</tr>
<tr>
<th class="header-bg text-left"><strong>Filter Material Performance</strong><br />
<strong>(Particle Collection Efficiency)</strong></th>
<td class="text-left" colspan="2">PL2 (99.0% or higher)</td>
</tr>
<tr>
<th class="header-bg text-left" colspan="2"><strong>Rated Operating Time<sup>※1</sup></strong></th>
<td class="text-left" colspan="2">Approx. 6.7 hours</td>
</tr>
<tr>
<th class="header-bg text-left" colspan="2"><strong>Actual Operating Time<sup>※2</sup></strong></th>
<td class="text-left" colspan="2">Approx. 4 ~ 9 hours</td>
</tr>
<tr>
<th class="header-bg text-left" colspan="2"><strong>Weight</strong></th>
<td class="text-left" colspan="2">Under 298g (Average 288g)</td>
</tr>
<tr>
<th class="header-bg text-left" colspan="2"><strong>Battery</strong></th>
<td class="text-left" colspan="2">Dedicated Rechargeable Lithium-ion Battery<br />
(Rated Voltage: 3.7V &#8211; Rated Capacity: 1100mAh)</td>
</tr>
<tr>
<th class="header-bg text-left" colspan="2"><strong>Recharge Cycles</strong></th>
<td class="text-left" colspan="2">Approx. 300 cycles<sup>※3</sup></td>
</tr>
<tr>
<th class="header-bg text-left" colspan="2"><strong>Charging Time</strong></th>
<td class="text-left" colspan="2">Approx. 3 hours<sup>※3</sup></td>
</tr>
<tr>
<th class="header-bg text-left" colspan="2"><strong>Electric Fan Durability</strong></th>
<td class="text-left" colspan="2">Approx. 2000 hours<sup>※3</sup></td>
</tr>
</tbody>
</table>
<p data-start="128" data-end="280"><strong data-start="128" data-end="144">※1: </strong>The duration positive internal pressure is maintained under standard national respiratory conditions during normal room operations.<br />
<strong data-start="282" data-end="298">※2: </strong>The duration positive internal pressure is maintained in a dusty environment, utilizing respiratory data from actual workers.</p>
<h2 data-start="128" data-end="280">Information on Welding Masks</h2>
<ul>
<li data-start="96" data-end="167">New fume countermeasures based on specific revised regulations.</li>
<li data-start="170" data-end="234">How to select a new mask based on specific revised regulations.</li>
<li data-start="237" data-end="291">Recommended masks for each required protection factor, etc.</li>
</ul>
<p><strong data-start="293" data-end="307">Note: </strong><em data-start="310" data-end="377">Protective regulations to prevent health hazards caused by specific chemical substances.</em></p>
<p><img loading="lazy" decoding="async" class=" wp-image-193588 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-3-300x111.jpg" alt="" width="511" height="189" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-3-300x111.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-3-768x285.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-3.jpg 1024w" sizes="auto, (max-width: 511px) 100vw, 511px" /></p>
<ul>
<li>Product colors may slightly differ from actual colors due to printing or photography lighting.</li>
<li>Product specifications and designs are subject to change without prior notice for continuous improvement.</li>
</ul>The post <a href="https://koueitrading.com/global/product/koken-bl-7005-bresslink/">Koken BL-7005 Bresslink</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken BL-1005-02 Bresslink</title>
		<link>https://koueitrading.com/global/product/koken-bl-1005-02-bresslink/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 19 Mar 2020 03:31:44 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=193572</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: BL-1005-02 Sakai Model BL-1005-02 Powered Air-Purifying Respirator (PAPR)Breath-Link Series Lightweight DesignApprox. 270g Benefits of &#8220;Breath-Link&#8221; during inhalation Easy Breathing Extended Work Duration Sakai Model BL-1005-02Includes Battery and ChargerNational Assay Certificate: No. TP1 From arc welding to tin plating countermeasures Sakai Model BL-1005-02Following the best-selling 1005 protective mask model, this is a [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-bl-1005-02-bresslink/">Koken BL-1005-02 Bresslink</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: BL-1005-02</p>
<h2>Sakai Model BL-1005-02</h2>
<p>Powered Air-Purifying Respirator (PAPR)<br data-start="125" data-end="128" data-is-only-node="" />Breath-Link Series</p>
<p data-start="63" data-end="95">Lightweight Design<br data-start="81" data-end="84" />Approx. 270g</p>
<p data-start="97" data-end="132">Benefits of &#8220;Breath-Link&#8221; during inhalation</p>
<ol>
<li data-start="137" data-end="150">Easy Breathing</li>
<li data-start="154" data-end="176">Extended Work Duration</li>
</ol>
<p data-start="178" data-end="260">Sakai Model BL-1005-02<br data-start="198" data-end="201" />Includes Battery and Charger<br data-start="218" data-end="221" />National Assay Certificate: No. TP1</p>
<p data-start="178" data-end="260">From arc welding to tin plating countermeasures</p>
<h3 data-start="178" data-end="260">Sakai Model BL-1005-02<br data-start="86" data-end="89" />Following the best-selling 1005 protective mask model, this is a Powered Air-Purifying Respirator (PAPR).</h3>
<h2 data-start="178" data-end="260">What is the Breath-Link Ventilation System?</h2>
<p>The Breath-Link series is equipped with a ventilation function synchronized with the user&#8217;s breathing rhythm, known as <strong data-start="193" data-end="201">BSFS</strong>. BSFS implements &#8220;silent blowing&#8221; during inhalation, which not only enhances protection but also minimizes breathing resistance and conserves power consumption.</p>
<p><img loading="lazy" decoding="async" class="wp-image-193579 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-3-3-300x115.jpg" alt="" width="459" height="176" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-3-3-300x115.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-3-3-768x296.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-3-3.jpg 1024w" sizes="auto, (max-width: 459px) 100vw, 459px" /><img loading="lazy" decoding="async" class=" wp-image-193578 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-3-300x183.jpg" alt="" width="454" height="277" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-3-300x183.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-3-768x468.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-3.jpg 1024w" sizes="auto, (max-width: 454px) 100vw, 454px" /></p>
<p data-start="63" data-end="91"><strong data-start="63" data-end="91">1. Benefits of Breath-Link</strong></p>
<ol>
<li data-start="96" data-end="204"><strong data-start="96" data-end="111">Easy Breathing</strong><br data-start="111" data-end="114" />Minimizes breathing discomfort by adjusting the airflow in synchronization with the user&#8217;s respiratory rhythm.</li>
<li data-start="209" data-end="344"><strong data-start="209" data-end="235">Extended Work Duration</strong><br data-start="235" data-end="238" />By restricting unnecessary noisy fan operation, the device consumes less power, allowing for longer continuous working hours.</li>
<li data-start="349" data-end="494"><strong data-start="349" data-end="380">Lightweight at approx. 270g</strong><br data-start="380" data-end="383" />Due to low power consumption, a smaller battery can be used, reducing the total mask weight to approximately 270g for easy mobility.</li>
</ol>
<p data-start="496" data-end="615"><strong data-start="496" data-end="516">2. Battery Drop Prevention</strong><br data-start="516" data-end="519" />The mask features a &#8220;release lever&#8221; inside the battery compartment to secure the battery and prevent it from falling out.</p>
<p data-start="496" data-end="615"><img loading="lazy" decoding="async" class="size-medium wp-image-193577 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-4-300x176.jpg" alt="" width="300" height="176" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-4-300x176.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-4-768x450.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-4.jpg 1024w" sizes="auto, (max-width: 300px) 100vw, 300px" /></p>
<p data-start="617" data-end="770"><strong data-start="617" data-end="655">3. Charger Replacement Parts</strong><br data-start="655" data-end="658" />Replacement components include the battery charger, filter cover, and other accessories, ensuring convenient maintenance when needed.</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56304" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-08_111951-removebg-preview.png" alt="" width="174" height="64" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56305" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-08_111942-removebg-preview.png" alt="" width="172" height="99" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56306" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-08_111929-removebg-preview.png" alt="" width="142" height="101" /></td>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><strong data-start="65" data-end="79">Battery Charger</strong>: For BL-1005-02</td>
<td><strong data-start="103" data-end="117">Filter Cover</strong>: For BL-1005-02</td>
<td><strong data-start="141" data-end="158">Exhalation Valve</strong>: Model T-8K</td>
</tr>
</tbody>
</table>
<h2 data-start="63" data-end="80"><strong data-start="63" data-end="80">Features</strong></h2>
<ul>
<li data-start="84" data-end="198"><strong data-start="84" data-end="107">Fit Checker</strong><br data-start="107" data-end="110" />Allows for quick and easy seal checks thanks to the integrated fit checker mechanism.</li>
<li data-start="202" data-end="316"><strong data-start="202" data-end="218">Adjustability</strong><br data-start="218" data-end="221" />Mask size and fit can be easily adjusted with the provided adjustable harness options.</li>
<li data-start="320" data-end="410"><strong data-start="320" data-end="363">High Airflow &amp; Anti-Corrosion</strong><br data-start="363" data-end="366" />Utilizes electrostatic filters to reduce operational noise while ensuring high performance.</li>
<li data-start="414" data-end="506"><strong data-start="414" data-end="450">High Elasticity and Durability</strong><br data-start="450" data-end="453" />Employs SB/SA type harnesses known for superior elasticity and long-lasting durability.</li>
<li data-start="510" data-end="596"><strong data-start="510" data-end="531">Silicone Material</strong><br data-start="531" data-end="534" />Made with highly durable and heat-resistant silicone for the facepiece.</li>
<li data-start="600" data-end="681"><strong data-start="600" data-end="621">Lightweight and Ergonomic</strong><br data-start="621" data-end="624" />Lightweight design makes it easy to carry and perfectly suited for active work environments.</li>
<li data-start="685" data-end="819"><strong data-start="685" data-end="703">Auto ON/OFF</strong><br data-start="703" data-end="706" />The fan automatically starts when the mask is donned and inhalation begins, and stops automatically when removed.</li>
<li data-start="823" data-end="898"><strong data-start="823" data-end="836">Alert System</strong><br data-start="836" data-end="839" />Provides notifications for battery replacement via the &#8220;Airflow Regulation&#8221; fan alert.</li>
<li data-start="902" data-end="942"><strong data-start="902" data-end="940">Compatible with Welding Shields+</strong></li>
</ul>
<h2>Performance and Specifications</h2>
<table>
<tbody>
<tr>
<th class="header-col" colspan="2"><strong>Model Name (Product Code)</strong></th>
<td class="data-cell" style="width: 27%;">BL-1005-02</td>
<td class="data-cell" style="width: 28%;">BL-1005X-02</td>
</tr>
<tr>
<th class="header-col" colspan="2"><strong>National Assay Certificate</strong></th>
<td class="data-cell">No. TP1</td>
<td class="data-cell">No. TP4</td>
</tr>
<tr>
<th class="header-col" colspan="2"><strong>Head Harness</strong></th>
<td class="data-cell">SB/SA Type</td>
<td class="data-cell">XRB/XRA Type</td>
</tr>
<tr>
<th class="header-col" colspan="2"><strong>Applicable Filter</strong></th>
<td class="data-cell" colspan="2">Mighty Micron Filter for BL-1005</td>
</tr>
<tr>
<th class="header-col" rowspan="3"><strong>Classification</strong></th>
<th class="sub-header"><strong>Fan Performance</strong></th>
<td class="data-cell" colspan="2">Standard Airflow Type</td>
</tr>
<tr>
<th class="sub-header"><strong>Inward Leakage Performance</strong></th>
<td class="data-cell" colspan="2">Class A (Below 1.0%)</td>
</tr>
<tr>
<th class="sub-header"><strong>Filter Material Performance</strong><br />
<strong>(Particle Collection Efficiency)</strong></th>
<td class="data-cell" colspan="2">PL1 (95.0% or higher)</td>
</tr>
<tr>
<th></th>
<th class="sub-header"><strong>Assigned Protection Factor</strong></th>
<td class="data-cell" colspan="2">14<sup>※4</sup></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-bg" colspan="2"><strong>Rated Operating Time<sup>※1</sup></strong></th>
<td class="data-cell" colspan="2">Average 8.5 hours</td>
</tr>
<tr>
<th class="header-bg" colspan="2"><strong>Actual Operating Time<sup>※2</sup></strong></th>
<td class="data-cell" colspan="2">Approx. 3.5 ~ 11 hours</td>
</tr>
<tr>
<th class="header-bg" colspan="2"><strong>Weight</strong></th>
<td class="data-cell">Under 278g (Avg. 271g)</td>
<td class="data-cell">Under 285g (Avg. 278g)</td>
</tr>
<tr>
<th class="header-bg" colspan="2"><strong>Battery</strong></th>
<td class="data-cell" colspan="2">Dedicated Rechargeable Lithium-ion Battery<br />
(Rated Voltage: 3.7V &#8211; Rated Capacity: 1100mAh)</td>
</tr>
<tr>
<th class="header-bg" colspan="2"><strong>Recharge Cycles</strong></th>
<td class="data-cell" colspan="2">Approx. 300 cycles<sup>※3</sup></td>
</tr>
<tr>
<th class="header-bg" colspan="2"><strong>Charging Time</strong></th>
<td class="data-cell" colspan="2">Approx. 3 hours<sup>※3</sup></td>
</tr>
<tr>
<th class="header-bg" colspan="2"><strong>Electric Fan Durability</strong></th>
<td class="data-cell" colspan="2">Approx. 2000 hours<sup>※3</sup></td>
</tr>
</tbody>
</table>
<p data-start="79" data-end="231"><strong data-start="79" data-end="95">Note 1:</strong><br data-start="95" data-end="98" />The duration positive internal pressure is maintained under standard national respiratory conditions during normal room operations.<br />
<strong data-start="233" data-end="249">Note 2:</strong><br data-start="249" data-end="252" />The duration positive internal pressure is maintained in a dusty environment, utilizing respiratory data from actual workers.<br />
<strong data-start="363" data-end="379">Note 3:</strong><br data-start="379" data-end="382" />Depending on usage conditions, the duration of positive internal pressure may be shorter than stated.<br />
<strong data-start="458" data-end="474">Note 4:</strong><br data-start="474" data-end="477" />Applicable for welding operations where the required protection factor is below 14.</p>
<p data-start="538" data-end="550"><strong data-start="538" data-end="548">Disclaimer:</strong></p>
<ul>
<li data-start="553" data-end="644">Product colors may slightly vary from actual colors due to printing and photographic conditions.</li>
<li data-start="647" data-end="758">Test results are for reference only. Actual operating times may vary based on the specific work environment.</li>
<li data-start="761" data-end="857">Product specifications and designs are subject to change without prior notice for continuous improvement.</li>
</ul>The post <a href="https://koueitrading.com/global/product/koken-bl-1005-02-bresslink/">Koken BL-1005-02 Bresslink</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken BL-321 Series Bresslink</title>
		<link>https://koueitrading.com/global/product/koken-bl-321-series-bresslink/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 19 Mar 2020 03:28:20 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=193566</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: BL-321 Series Lightweight performance in a cordless design Sakai Model BL-321 Series A Powered Air-Purifying Respirator (PAPR) that minimizes leakage risks, ensuring safety while reducing the physical burden on the user through a lightweight facepiece design integrated with a motor and battery.The BL-321 series utilizes &#8220;Breath-Link&#8221; technology to synchronize airflow with [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-bl-321-series-bresslink/">Koken BL-321 Series Bresslink</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: BL-321 Series</p>
<p><strong>Lightweight performance in a cordless design</strong></p>
<h2 data-start="104" data-end="131"><strong data-start="104" data-end="131">Sakai Model BL-321 Series</strong></h2>
<p data-start="133" data-end="591">A Powered Air-Purifying Respirator (PAPR) that minimizes leakage risks, ensuring safety while reducing the physical burden on the user through a lightweight facepiece design integrated with a motor and battery.<br data-start="314" data-end="317" />The BL-321 series utilizes &#8220;Breath-Link&#8221; technology to synchronize airflow with the user&#8217;s breathing rhythm, reducing fatigue and conserving battery power during use. This is a lightweight, cordless series featuring a compact battery, delivering both comfort and safety.</p>
<p data-start="133" data-end="591">Lightest weight in the domestic market※<br data-start="98" data-end="101" />Enhanced water resistance<br data-start="135" data-end="138" data-is-only-node="" />Replaceable filters (PL1/PL3 classifications)</p>
<p data-start="133" data-end="591">※The BL-321S is a Japanese domestic PAPR product, released in May 2018 (according to company research).</p>
<p data-start="133" data-end="591"><img loading="lazy" decoding="async" class="aligncenter wp-image-56310" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-08_113549-removebg-preview.png" alt="" width="187" height="225" /></p>
<p data-start="133" data-end="591"><strong data-start="65" data-end="89">Sakai Model BL-321S-02</strong><br data-start="89" data-end="92" />Powered Air-Purifying Respirator<br data-start="128" data-end="131" data-is-only-node="" />Uses BLA-62 Filter<br data-start="152" data-end="155" />Particle Collection Efficiency: 95.0% or higher (PL1)</p>
<p data-start="133" data-end="591"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56311" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-08_113728-removebg-preview.png" alt="" width="158" height="197" /></p>
<p data-start="133" data-end="591"><strong data-start="194" data-end="218">Sakai Model BL-321H-02</strong><br data-start="218" data-end="221" />Powered Air-Purifying Respirator<br data-start="257" data-end="260" data-is-only-node="" />Uses BRD-82 Filter<br data-start="281" data-end="284" />Particle Collection Efficiency: 99.97% or higher (PL3)</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<th class="xl65" style="height: 14.4pt; width: 240pt;" colspan="5" width="320" height="19"><strong>One device suited for multiple operations!</strong></th>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19">Metal grinding and general dust</td>
<td>Welding operations</td>
<td>Tunnel construction</td>
<td>Asbestos removal</td>
<td>Indium handling operations</td>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56312" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-113919.png" alt="" width="300" height="210" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56313" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-113927.png" alt="" width="286" height="214" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56314" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-113934.png" alt="" width="286" height="211" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56315" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-113941.png" alt="" width="284" height="208" /></p>
<p>(BL-321H model only)</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56316" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-113947.png" alt="" width="285" height="210" /></p>
<p>(BL-321H model only)</td>
</tr>
</tbody>
</table>
<h2>Easier to use with Breath-Link Technology</h2>
<p data-start="109" data-end="490">Breath-Link technology, featuring a unique blower structure <strong data-start="170" data-end="180">(BSFS)</strong>, implements &#8220;silent blowing&#8221; during inhalation and stops blowing during exhalation, minimizing fatigue when wearing the respirator. By utilizing a cordless electric fan, this product reduces power consumption while achieving a significantly lighter weight compared to conventional devices.</p>
<ul>
<li data-start="494" data-end="621"><strong data-start="494" data-end="513">Lightweight</strong><br data-start="513" data-end="516" />Improved fan efficiency reduces battery power consumption, allowing for a smaller battery and greater mobility.</li>
<li data-start="625" data-end="732"><strong data-start="625" data-end="640">Easy Breathing</strong><br data-start="640" data-end="643" />Synchronized airflow matches your breathing rhythm, reducing the discomfort often associated with wearing masks.</li>
<li data-start="736" data-end="856"><strong data-start="736" data-end="761">Reduced Operating Costs</strong><br data-start="761" data-end="764" />Precise control of fan rotation speed conserves energy and lowers long-term operating costs.</li>
</ul>
<h2>Airflow Warning System for Safe Operation</h2>
<p data-start="118" data-end="263">To maintain the safety of a Powered Air-Purifying Respirator, it is crucial to sustain adequate airflow and keep the internal facepiece pressure positive.<br data-start="231" data-end="234" data-is-only-node="" />The BL-321 notifies the user via an &#8220;airflow alert&#8221; if the internal pressure drops due to filter clogging or battery depletion, which causes a reduction in airflow.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56317" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-114331.png" alt="" width="229" height="171" /></p>
<p data-start="102" data-end="174">The system maintains stable internal pressure until a filter replacement is required.</p>
<ul>
<li data-start="178" data-end="284">Filter clogs → Airflow decreases → Internal pressure drops → Constant airflow warning triggered</li>
<li data-start="287" data-end="347">Battery consumption notification → Low battery alert triggered</li>
</ul>
<p data-start="349" data-end="434">Rhythmic airflow helps regulate pressure and minimizes energy consumption.</p>
<h2>Performance and Specifications</h2>
<table class="spec-table">
<tbody>
<tr>
<th class="bg-header" colspan="2"><strong>Model Name (Product Code)</strong></th>
<td class="col-data">Sakai Model BL-321S-02</td>
<td class="col-data">Sakai Model BL-321H-02</td>
</tr>
<tr>
<th class="bg-header" colspan="2"><strong>National Assay Certificate</strong></th>
<td>No. TP100</td>
<td>No. TP101</td>
</tr>
<tr>
<th class="bg-header" colspan="2"><strong>Applicable Filter</strong></th>
<td>Alpha Ring Filter BLA-62</td>
<td>Alpha Ring Filter BRD-82</td>
</tr>
<tr>
<th class="bg-header" colspan="2"><strong>Head Harness</strong></th>
<td colspan="2">SBW/SAW Type</td>
</tr>
<tr>
<th class="bg-header col-header-main" rowspan="3"><strong>Classification</strong></th>
<th class="bg-header col-header-sub"><strong>Fan Performance</strong></th>
<td colspan="2">High Airflow Type</td>
</tr>
<tr>
<th class="bg-header"><strong>Inward Leakage Performance</strong></th>
<td>Class B (Below 5.0%)</td>
<td>Class S (Below 0.1%)</td>
</tr>
<tr>
<th class="bg-header"><strong>Filter Material Performance</strong></th>
<td>PL1 (95.0% or higher)</td>
<td>PL3 (99.97% or higher)</td>
</tr>
<tr>
<th class="bg-header" colspan="2"><strong>Rated Operating Time<sup>※1</sup></strong></th>
<td>Approx. 3.5 hours</td>
<td>Approx. 3 hours</td>
</tr>
<tr>
<th class="bg-header" colspan="2"><strong>Actual Operating Time<sup>※2</sup></strong></th>
<td>Approx. 5 ~ 9 hours</td>
<td>Approx. 3 ~ 6 hours</td>
</tr>
<tr>
<th class="bg-header" colspan="2"><strong>Weight</strong></th>
<td>Under 252g (Avg. 245g)</td>
<td>Under 265g (Avg. 257g)</td>
</tr>
<tr>
<th class="bg-header" colspan="2"><strong>Battery</strong></th>
<td colspan="2">Dedicated Rechargeable Lithium-ion Battery (Rated Voltage: 3.7V &#8211; Rated Capacity: 1100mAh)</td>
</tr>
<tr>
<th class="bg-header" colspan="2"><strong>Recharge Cycles</strong></th>
<td colspan="2">Approx. 300 cycles<sup>※3</sup></td>
</tr>
<tr>
<th class="bg-header" colspan="2"><strong>Charging Time</strong></th>
<td colspan="2">Approx. 3 hours<sup>※3</sup></td>
</tr>
<tr>
<th class="bg-header" colspan="2"><strong>Electric Fan Durability</strong></th>
<td colspan="2">Approx. 2,000 hours<sup>※3</sup></td>
</tr>
</tbody>
</table>
<p>※1 The duration positive pressure is maintained inside the mask under high airflow breathing conditions in a standard room (National Assay Standard).<br />
※2 The duration positive pressure is maintained inside the mask in a dusty environment, based on actual worker breathing data during operations.<br />
※3 May be shorter depending on usage conditions.</p>
<h2>Water-Resistant Design Prevents Ingress ※1</h2>
<p data-start="132" data-end="392"><img loading="lazy" decoding="async" class="aligncenter wp-image-56318" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-114344.png" alt="" width="176" height="170" />Further improved water resistance necessary for actual field work, achieving an IP55 dust and water resistance rating ※2. Designed to protect against dust and water jets. Can be used during sudden rain or in operations involving water splashing.</p>
<p data-start="394" data-end="408"><strong data-start="394" data-end="408">Notes:</strong></p>
<ul>
<li data-start="411" data-end="494"><strong data-start="411" data-end="417">※1</strong>: Water resistance is not guaranteed in all usage situations.</li>
<li data-start="497" data-end="581"><strong data-start="497" data-end="503">※2</strong>: Complies with JIS C0920 standard for degrees of protection provided by enclosures (IP Code).</li>
</ul>
<h2>Maintenance</h2>
<p data-start="82" data-end="232">Adhered dust can be cleaned off with running water.<br data-start="121" data-end="124" />For stubborn dirt that cannot be wiped away, the unit can be cleaned by washing it with water. <strong data-start="227" data-end="232">※</strong></p>
<p data-start="234" data-end="248"><strong data-start="234" data-end="248">Notes:</strong></p>
<ul>
<li data-start="251" data-end="306"><strong data-start="251" data-end="256">※</strong>: Be sure to use the maintenance plug (sold separately) during washing.</li>
<li data-start="309" data-end="374"><strong data-start="309" data-end="314">※</strong>: Do not submerge the unit in a bucket or spray water into the inside of the mask.</li>
<li data-start="377" data-end="422"><strong data-start="377" data-end="382">※</strong>: The battery and filters cannot be washed with water.</li>
</ul>
<p><img loading="lazy" decoding="async" class="size-medium wp-image-193568 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-1-3-300x224.jpg" alt="" width="300" height="224" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-1-3-300x224.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-1-3-768x574.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-1-3.jpg 1024w" sizes="auto, (max-width: 300px) 100vw, 300px" /></p>
<h2>Battery Drop Prevention</h2>
<p>The battery is secured by a &#8220;Release Lever&#8221; inside the battery case to prevent it from falling out.</p>
<p><img loading="lazy" decoding="async" class="size-medium wp-image-193570 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-2-2-300x136.jpg" alt="" width="300" height="136" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-2-2-300x136.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-2-2-768x347.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-2-2.jpg 1024w" sizes="auto, (max-width: 300px) 100vw, 300px" /></p>
<p data-start="63" data-end="86"><strong data-start="63" data-end="86">Other Features:</strong></p>
<ul>
<li data-start="90" data-end="239"><strong data-start="90" data-end="116">Failsafe Protection</strong><br data-start="116" data-end="119" />Even if the battery is removed or depleted, the mask maintains particulate protection equivalent to a standard non-powered dust respirator.</li>
<li data-start="243" data-end="395"><strong data-start="243" data-end="278">Auto ON/OFF Function</strong><br data-start="278" data-end="281" />The fan automatically starts when the mask is donned and the user inhales, and it automatically stops when the mask is removed.</li>
<li data-start="399" data-end="479"><strong data-start="399" data-end="420">Silicone Material</strong><br data-start="420" data-end="423" />Utilizes silicone material for a comfortable and durable skin seal.</li>
<li data-start="483" data-end="564"><strong data-start="483" data-end="499">SBW/SAW Type Harness</strong><br data-start="499" data-end="502" />Uses SBW/SAW type harnesses for high durability and stress resistance.</li>
<li data-start="568" data-end="657"><strong data-start="568" data-end="584">Speaking Diaphragm</strong><br data-start="584" data-end="587" />Equipped with a built-in voice transmitter to allow communication and instructions while wearing the mask.</li>
</ul>
<p><strong>Disclaimer:</strong></p>
<ul>
<li data-start="77" data-end="167">The color of the product may differ from the actual color due to printing or photography lighting.</li>
<li data-start="170" data-end="270">Product specifications and designs are subject to change without prior notice for improvement purposes.</li>
</ul>The post <a href="https://koueitrading.com/global/product/koken-bl-321-series-bresslink/">Koken BL-321 Series Bresslink</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken BL-1180H Dust Respirator</title>
		<link>https://koueitrading.com/global/product/koken-bl-1180h-dust-respirator/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 19 Mar 2020 03:22:49 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=193562</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: BL-1180H Usable for a wide variety of tasks! Replaceable Dust Respirator Sakai Model BL-1180H The BL-1180H is the highest-performing dust respirator in our protective mask lineup, featuring an RL3 classification (particle collection efficiency over 99.9%). This mask can be used for both indoor and outdoor construction site operations. Featuring replaceable filters, [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-bl-1180h-dust-respirator/">Koken BL-1180H Dust Respirator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: BL-1180H</p>
<p><strong>Usable for a wide variety of tasks!</strong></p>
<p>Replaceable Dust Respirator<br />
Sakai Model BL-1180H</p>
<p>The BL-1180H is the highest-performing dust respirator in our protective mask lineup, featuring an RL3 classification (particle collection efficiency over 99.9%).</p>
<p>This mask can be used for both indoor and outdoor construction site operations. Featuring replaceable filters, it fits the profile of a half-face dust mask. Additionally, the filter can be swapped with a chemical cartridge for use as a gas mask in toxic environments.</p>
<table>
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter wp-image-56323" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-08_132933-removebg-preview-1.png" alt="" width="199" height="225" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56324" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-133053.png" alt="" width="139" height="113" /></td>
</tr>
<tr>
<td><strong>National Model Assay Certificate No. TM788</strong></td>
<td><strong>Alpha Ring Filter</strong><br data-start="128" data-end="131" data-is-only-node="" /><strong>Model RD-8</strong></td>
</tr>
</tbody>
</table>
<p><strong>RL3<br />
Primary Applications<br />
</strong></p>
<ul>
<li data-start="91" data-end="145">Asbestos removal operations (Level 1 tasks) ※1</li>
<li data-start="148" data-end="197">Indium compound manufacturing and handling operations</li>
<li data-start="200" data-end="228">Dioxin handling operations</li>
<li data-start="231" data-end="250">Welding operations</li>
<li data-start="253" data-end="270">Grinding operations</li>
</ul>
<p data-start="274" data-end="362"><strong>Note:</strong> Usage may be restricted depending on conditions such as workplace concentration levels.<br />
For details, please refer to the &#8220;Examples of Applicable Work&#8221; below.</p>
<p data-start="274" data-end="362"><strong>Examples of Applicable Work</strong><br data-start="99" data-end="102" />Dust types and work descriptions</p>
<ul>
<li data-start="144" data-end="338"><strong data-start="144" data-end="186">Work with risk of Dioxin exposure</strong>:<br data-start="187" data-end="190" />Level 1 tasks utilizing asbestos removal masks classified under &#8220;Category 3&#8221; or &#8220;Category 4&#8221; for asbestos abatement.</li>
<li data-start="343" data-end="452"><strong data-start="343" data-end="390">Indium compound manufacturing and handling</strong>:<br data-start="391" data-end="394" />Tasks where indium compound concentrations are below 3 µg/m³.</li>
<li data-start="457" data-end="585"><strong data-start="457" data-end="493">Metal-related operations</strong>:<br data-start="494" data-end="497" />Tasks generating metal fumes (including welding fumes) in areas where metal fumes are present.</li>
<li data-start="590" data-end="741"><strong data-start="590" data-end="655">Work generating dust from substances with concentrations below 0.1 mg/m³</strong>:<br data-start="656" data-end="659" />Tasks in areas where dust is generated from substances at concentrations lower than 0.1 mg/m³.</li>
</ul>
<p data-start="760" data-end="875"><strong data-start="760" data-end="766">※1</strong>: When removing Level 1 plasterboards using cutting methods, powered air-purifying respirators (PAPR) must be used.<br />
<strong data-start="878" data-end="884">※2</strong>: Welding operations requiring a protection factor below 10.</p>
<h2 data-start="760" data-end="875">Replace Filter with a Chemical Cartridge for Gas Mask Usage</h2>
<p>Painting, washing, and degreasing operations, as well as solvent handling tasks.</p>
<p>By exchanging the filter for an absorbent cartridge, it can be used as a G-7 Gas Mask.<br data-start="292" data-end="295" />National Model Assay Certificate No. TN382.</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56325" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-133349.png" alt="" width="233" height="274" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56326" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-133359.png" alt="" width="149" height="85" /></td>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><strong>When KGC-10C Cartridge is attached</strong></td>
<td><strong>KGC-10C-03 Organic Vapor Cartridge</strong><br />
Select the appropriate cartridge based on the specific gases and vapors in the environment.<br />
See the back page for &#8220;Compatible Cartridge Types&#8221;.</td>
</tr>
</tbody>
</table>
<h2>Respirator Features</h2>
<p><strong>For the 1180H model equipped with the Fit Checker, simply pull the lever to perform an immediate Fit Check.</strong><br data-start="208" data-end="211" />Pull up the Fit Checker and instantly test for leaks!</p>
<p>Even with a high-efficiency filter, wearing the mask incorrectly negates its protective value. With the integrated Fit Checker model, a simple lever operation is all it takes to perform a user seal check, making fit verification fast and easy.</p>
<p><img loading="lazy" decoding="async" class="wp-image-193564 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-13-300x104.jpg" alt="" width="479" height="166" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-13-300x104.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-13-768x266.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-13.jpg 1024w" sizes="auto, (max-width: 479px) 100vw, 479px" /></p>
<p><strong>Facepiece contact area designed for optimal fit</strong></p>
<p data-start="122" data-end="322">Skin-friendly silicone material<br data-start="161" data-end="164" />The silicone facepiece reduces skin irritation and is less likely to cause dryness. This material remains highly flexible, accommodating facial movements to provide a stable and comfortable fit.</p>
<p data-start="324" data-end="580">Freeposition Underchin<br data-start="340" data-end="343" />A specialized design providing an optimal facial contact shape.<br data-start="401" data-end="404" />By adjusting the nose section first and then securing the chin area, the mask accommodates varying face sizes, preventing leaks in vulnerable areas such as the bridge of the nose.</p>
<p data-start="324" data-end="580"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56328" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-134427.png" alt="" width="293" height="140" /></p>
<h2>Respirator Performance Specifications</h2>
<table class="spec-table">
<tbody>
<tr>
<th class="header-dark-blue" colspan="3"><strong>Dust Respirator</strong></th>
</tr>
<tr>
<th class="bg-light-blue" colspan="2"><strong>Model Name (Product Code)</strong></th>
<td class="bg-white">Sakai Model 1180H</td>
</tr>
<tr>
<th class="bg-light-blue" colspan="2"><strong>National Assay Certificate</strong></th>
<td class="bg-white">No. TM788</td>
</tr>
<tr>
<th class="bg-light-blue" colspan="2"><strong>Filter Material</strong></th>
<td class="bg-white">Alpha Ring Filter Model RD-8</td>
</tr>
<tr>
<th class="bg-light-blue" colspan="2"><strong>Classification</strong></th>
<td class="bg-white">Replaceable Type ・ Direct Connection</td>
</tr>
<tr>
<th class="bg-light-blue" colspan="2"><strong>Respirator Type</strong></th>
<td class="bg-white">Half-face</td>
</tr>
<tr>
<th class="bg-light-blue" colspan="2"><strong>Performance (Classification)</strong></th>
<td class="bg-white">RL3</td>
</tr>
<tr>
<th class="bg-light-blue" colspan="2"><strong>Assigned Protection Factor</strong></th>
<td class="bg-white">10</td>
</tr>
<tr>
<th class="vertical-header" rowspan="5"><strong>Internal</strong><br />
<strong>Standard</strong></th>
<th class="bg-light-blue"><strong>Particle Collection Efficiency</strong></th>
<td class="bg-white">Above 99.9%</td>
</tr>
<tr>
<th class="bg-light-blue"><strong>Inhalation Resistance</strong></th>
<td class="bg-white">Below 88Pa (including filter)</td>
</tr>
<tr>
<th class="bg-light-blue"><strong>Exhalation Resistance</strong></th>
<td class="bg-white">Below 45Pa</td>
</tr>
<tr>
<th class="bg-light-blue"><strong>CO2 Concentration Increase</strong></th>
<td class="bg-white">Below 0.5%</td>
</tr>
<tr>
<th class="bg-light-blue"><strong>Weight</strong></th>
<td class="bg-white">Below 134g (including filter)</td>
</tr>
<tr>
<th class="bg-light-blue" colspan="2"><strong>Inhalation Resistance Increase (Average)</strong></th>
<td class="bg-white">89Pa</td>
</tr>
</tbody>
</table>
<p>The figures above indicate the performance when using the standard product (Size M mask, RB type harness) without any accessories/options attached.<br />
Masks are available in two sizes: Size M (Standard) and Size S.</p>
<h2>Compatible Filters</h2>
<table class="filter-table">
<tbody>
<tr>
<th class="header-green"><strong>Filter Name</strong></th>
<th class="header-green"><strong>Model Name When Attached</strong></th>
<th class="header-green" style="width: 15%;"><strong>Dust Protection</strong><br />
<strong>(Classification)</strong></th>
</tr>
<tr>
<td class="bg-beige">Alpha Ring Filter<br />
Model RD-8 (Included)</td>
<td class="bg-beige">Sakai Model 1180H<br />
No. TM788</td>
<td class="bg-beige text-center">RL3</td>
</tr>
<tr>
<td class="bg-beige">Alpha Ring Filter<br />
Model LAS-51 (Sold separately)</td>
<td class="bg-beige">Sakai Model 1180-05<br />
No. TM538</td>
<td class="bg-beige text-center">RL2</td>
</tr>
</tbody>
</table>
<p>The 1180H model can be used as the 1180-05 model dust respirator by replacing the filter with the LAS-51 Alpha Ring Filter. Please check the instruction manual for applicable operations.</p>
<h2>Compatible Chemical Cartridges (Sold Separately)</h2>
<table class="spec-table">
<tbody>
<tr>
<th class="header-dark-green" style="width: 20%;"><strong>Target Gas Type</strong></th>
<th class="header-dark-green" style="width: 60%;"><strong>Cartridge Name</strong></th>
<th class="header-dark-green" style="width: 20%;"><strong>Dust Protection</strong><br />
<strong>(Classification)</strong></th>
</tr>
<tr>
<td class="bg-light-green" rowspan="2">For Halogen Gases</td>
<td class="bg-light-green">KGC-10A-03 For Halogen Gases</td>
<td class="bg-light-green text-center">&#8212;&#8211;</td>
</tr>
<tr>
<td class="bg-light-green">KGC-10A-03 For Halogen Gases<br />
When Mighty Micron Filter is attached</td>
<td class="bg-light-green text-center">Yes (S1) <sup>※1※3</sup></td>
</tr>
<tr>
<td class="bg-light-green" rowspan="2">For Acid Gases</td>
<td class="bg-light-green">KGC-10B-03 For Acid Gases</td>
<td class="bg-light-green text-center">&#8212;&#8211;</td>
</tr>
<tr>
<td class="bg-light-green">KGC-10B-03 For Acid Gases<br />
When Mighty Micron Filter is attached</td>
<td class="bg-light-green text-center">Yes <sup>※1※2※3</sup></td>
</tr>
<tr>
<td class="bg-light-green" rowspan="6">For Organic Vapors</td>
<td class="bg-light-green">KGC-10C-03 For Organic Vapors</td>
<td class="bg-light-green text-center">&#8212;&#8211;</td>
</tr>
<tr>
<td class="bg-light-green">KGC-10C-03 For Organic Vapors<br />
When Mighty Micron Filter is attached</td>
<td class="bg-light-green text-center">Yes (S1) <sup>※1※3</sup></td>
</tr>
<tr>
<td class="bg-light-green">Model KGC-10 L For Organic Vapors (C)</td>
<td class="bg-light-green text-center">&#8212;&#8211;</td>
</tr>
<tr>
<td class="bg-light-green">Model KGC-10 L For Organic Vapors (C)<br />
When Mighty Micron Filter is attached</td>
<td class="bg-light-green text-center">Yes (S1) <sup>※1※3</sup></td>
</tr>
<tr>
<td class="bg-light-green">KGC-10MC-04 For Organic Vapors ・ Dust</td>
<td class="bg-light-green text-center">Yes (S1) <sup>※1※3</sup></td>
</tr>
<tr>
<td class="bg-light-green">Model KGC-10 LMC-02 For Organic Vapors ・ Dust</td>
<td class="bg-light-green text-center">Yes (S1) <sup>※1※3</sup></td>
</tr>
<tr>
<td class="bg-light-green">For Ethylene Oxide</td>
<td class="bg-light-green">KGC-10EOG (Pack of 5) For Ethylene Oxide</td>
<td class="bg-light-green text-center">&#8212;&#8211;</td>
</tr>
<tr>
<td class="bg-light-green">For Formaldehyde</td>
<td class="bg-light-green">KGC-10FA-03 (Pack of 5) For Formaldehyde</td>
<td class="bg-light-green text-center">&#8212;&#8211;</td>
</tr>
<tr>
<td class="bg-light-green" rowspan="2">For Formaldehyde<br />
・ Organic Vapors</td>
<td class="bg-light-green">Model KGC-10 L FA For Formaldehyde ・ Organic Vapors</td>
<td class="bg-light-green text-center">&#8212;&#8211;</td>
</tr>
<tr>
<td class="bg-light-green">Model KGC-10 L FA For Formaldehyde ・ Organic Vapors<br />
When Mighty Micron Filter is attached</td>
<td class="bg-light-green text-center">Yes (S1) <sup>※1※3</sup></td>
</tr>
</tbody>
</table>
<p>※1 Attached to the chemical cartridge for use against dust mixed in toxic gases or vapors.<br />
※2 Represents a testing standard equivalent to &#8220;Class S1&#8221; of the national assay regulations.<br />
※3 The Assigned Protection Factor against dust, etc., is &#8220;4&#8221;.</p>The post <a href="https://koueitrading.com/global/product/koken-bl-1180h-dust-respirator/">Koken BL-1180H Dust Respirator</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken Hi-Luck Product Series</title>
		<link>https://koueitrading.com/global/product/koken-hi-luck-product-series/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Tue, 17 Mar 2020 07:31:06 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=193354</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. If you prioritize fit capability: Hi-Luck Series by SakaiThe Hi-Luck series is designed with a three-dimensional FF Lip (Free Fit Lip) structure that enhances fitting capabilities.Masks equipped with the FF Lip provide high airtightness and easily adapt to facial movements, delivering a natural, secure fit. &#160; Excellent skin contact feel and superior [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-hi-luck-product-series/">Koken Hi-Luck Product Series</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.</p>
<p><img loading="lazy" decoding="async" class=" wp-image-193358 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-2-300x204.jpg" alt="" width="399" height="271" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-2-300x204.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-2-768x522.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-2.jpg 1024w" sizes="auto, (max-width: 399px) 100vw, 399px" /></p>
<p><strong>If you prioritize fit capability:</strong></p>
<p><strong data-start="49" data-end="84">Hi-Luck Series by Sakai</strong><br data-start="84" data-end="87" />The <strong data-start="101" data-end="112" data-is-only-node="">Hi-Luck</strong> series is designed with a three-dimensional <strong data-start="149" data-end="159">FF Lip (Free Fit Lip)</strong> structure that enhances fitting capabilities.<br data-start="191" data-end="194" />Masks equipped with the <strong data-start="210" data-end="220">FF Lip</strong> provide high airtightness and easily adapt to facial movements, delivering a natural, secure fit.</p>
<p>&nbsp;</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56334" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-140735.png" alt="" width="230" height="237" /></p>
<ul>
<li data-start="156" data-end="210">Excellent skin contact feel and superior moisture absorption.</li>
<li data-start="213" data-end="284">Easy to don and reduces skin irritation due to the use of urethane rubber material.</li>
<li data-start="287" data-end="332">Fit can be adjusted while wearing the mask.</li>
<li data-start="335" data-end="421">Convenient folding function for easy carrying (excluding Hi-Luck 550/555 models).</li>
<li data-start="424" data-end="485">Prevents internal condensation and features an anti-fog filter design.</li>
</ul>
<p>To protect the environment, no metal components are used, ensuring safe disposal via incineration.</p>
<h2><strong>Hi-Luck</strong> Series</h2>
<table>
<tbody>
<tr>
<th class="header-col" colspan="3" rowspan="2"><strong>Product Name /</strong><br />
<strong>Image</strong></th>
<th style="text-align: left;"><strong>Hi-Luck 350 DS2 N95</strong><br />
<strong>Hi-Luck 350T DS2</strong></th>
<th style="text-align: left;"><strong>Hi-Luck 355 DS2</strong><br />
<strong>Hi-Luck 355T DS2</strong></th>
<th style="text-align: left;"><strong>Hi-Luck 650 DS2</strong><br />
<strong>Hi-Luck 650T DS2</strong></th>
<th style="text-align: left;"><strong>Hi-Luck 550 DS1</strong></th>
</tr>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56335" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-141047.png" alt="" width="202" height="186" /></p>
<div class="protection-factor">Assigned Protection Factor: 10</div>
</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56336" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-141054.png" alt="" width="211" height="179" /></p>
<div class="protection-factor">Assigned Protection Factor: 10</div>
</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56337" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-141101.png" alt="" width="208" height="184" /></p>
<div class="protection-factor">Assigned Protection Factor: 10</div>
</td>
<td>Deodorizing Type<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56338" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-141116.png" alt="" width="121" height="118" /></p>
<div class="protection-factor">Assigned Protection Factor: 4</div>
</td>
</tr>
<tr>
<th class="header-col" colspan="3"><strong>Features / Certification Code</strong></th>
<td class="text-left small-text">National Certification No. TM339 / TM609<br />
※Image shows Hi-Luck 350</td>
<td class="text-left small-text"><strong>With Exhalation Valve</strong><br />
National Certification No. TM340 / TM628</td>
<td class="text-left small-text"><strong>Uses Bipro-Micron Filter</strong><br />
(Also available as 655/655T with valve)<br />
National Certification No. TM597</td>
<td class="text-left small-text"><strong>Removes trace organic odors simultaneously with dust</strong><br />
(Also available as 555 with valve)<br />
National Certification No. TM383</td>
</tr>
<tr>
<th rowspan="9"><strong>Performance</strong></th>
<th class="header-col text-left" colspan="2"><strong>Particle Collection Efficiency (NaCl Particles)</strong></th>
<td>95.0% or higher (98.4%)</td>
<td>95.0% or higher (97.9%)</td>
<td>95.0% or higher (99.4%)</td>
<td>80.0% or higher (88.2%)</td>
</tr>
<tr>
<th class="header-col text-left" colspan="2"><strong>Inhalation Resistance</strong></th>
<td>50Pa or less (35Pa)</td>
<td>50Pa or less (37Pa)</td>
<td>50Pa or less (36Pa)</td>
<td>40Pa or less (29Pa)</td>
</tr>
<tr>
<th class="header-col text-left" colspan="2"><strong>Exhalation Resistance</strong></th>
<td>50Pa or less (35Pa)</td>
<td>36Pa or less (21Pa)</td>
<td>50Pa or less (36Pa)</td>
<td>40Pa or less (28Pa)</td>
</tr>
<tr>
<th class="header-col text-left" colspan="2"><strong>Resistance Increase Value</strong></th>
<td>&#8212;&#8212; (135Pa)</td>
<td>&#8212;&#8212; (203Pa)</td>
<td>&#8212;&#8212; (90Pa)</td>
<td>&#8212;&#8212; (91Pa)</td>
</tr>
<tr>
<th class="header-col text-left" colspan="2"><strong>CO2 Concentration Increase / Dead Space Volume</strong></th>
<td>1.0% or less / 400cm<sup>3</sup> or less<br />
(0.45% / 178cm<sup>3</sup>)</td>
<td>1.0% or less / 400cm<sup>3</sup> or less<br />
(0.41% / 165cm<sup>3</sup>)</td>
<td>1.0% or less / 400cm<sup>3</sup> or less<br />
(0.37% / 149cm<sup>3</sup>)</td>
<td>1.0% or less / 400cm<sup>3</sup> or less<br />
(0.73% / 293cm<sup>3</sup>)</td>
</tr>
<tr>
<th class="header-col text-left" colspan="2"><strong>Wet Resistance Value</strong></th>
<td>&#8212;&#8212; (31Pa)</td>
<td>&#8212;&#8212; (22Pa)</td>
<td>&#8212;&#8212; (30Pa)</td>
<td>&#8212;&#8212; (23Pa)</td>
</tr>
<tr>
<th class="header-col text-left" style="position: relative;" rowspan="2"><strong>Weight</strong></th>
<th><strong>Standard</strong></th>
<td>350: 12.1g or less (9.1g)</td>
<td>355: 14.1g or less (11.1g)</td>
<td>650: 12.6g or less (9.9g)</td>
<td>550: 12.3g or less (9.8g)</td>
</tr>
<tr>
<th><strong>Hook Type (T)</strong></th>
<td>350T: 12.7g or less (9.7g)</td>
<td>355T: 14.5g or less (11.5g)</td>
<td>650T: 13.1g or less (10.2g)</td>
<td>&#8212;&#8212;</td>
</tr>
<tr>
<th class="header-col text-left" colspan="2"><strong>Maximum Use Time Limit</strong></th>
<td>13 hours</td>
<td>15 hours</td>
<td>20 hours</td>
<td>12 hours</td>
</tr>
</tbody>
</table>
<p>* Values in parentheses ( ) represent the measured average values.</p>The post <a href="https://koueitrading.com/global/product/koken-hi-luck-product-series/">Koken Hi-Luck Product Series</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken VP-300 Personal Cooling Unit</title>
		<link>https://koueitrading.com/global/product/koken-vp-300-personal-cooling-unit/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Tue, 17 Mar 2020 07:20:27 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=193348</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: VP-300 Are you prepared for heatstroke prevention? Starting June 1, 2025, revised industrial safety regulations will take effect, making heatstroke prevention a mandatory obligation. To prevent severe heatstroke among workers at risk, employers must implement &#8220;preparatory measures,&#8221; &#8220;establish protocols,&#8221; and &#8220;notify relevant parties.&#8221; Blast away the heat inside your work clothes [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-vp-300-personal-cooling-unit/">Koken VP-300 Personal Cooling Unit</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: VP-300</p>
<p>Are you prepared for heatstroke prevention?<br />
Starting June 1, 2025, revised industrial safety regulations will take effect, making heatstroke prevention a mandatory obligation. To prevent severe heatstroke among workers at risk, employers must implement &#8220;preparatory measures,&#8221; &#8220;establish protocols,&#8221; and &#8220;notify relevant parties.&#8221;</p>
<p data-start="52" data-end="99"><img loading="lazy" decoding="async" class="size-medium wp-image-193352 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-2-224x300.jpg" alt="" width="224" height="300" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-2-224x300.jpg 224w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-2.jpg 765w" sizes="auto, (max-width: 224px) 100vw, 224px" /></p>
<p data-start="52" data-end="99"><strong data-start="52" data-end="99">Blast away the heat inside your work clothes</strong></p>
<h2>VP-300 Personal Cooling Unit</h2>
<p data-start="56" data-end="118"><strong data-start="56" data-end="118">Designed for body cooling in high-temperature environments:</strong></p>
<p data-start="120" data-end="192">★ <strong data-start="122" data-end="146">No power supply required</strong>【*1】<br data-start="150" data-end="153" />Can be operated without electricity.</p>
<p data-start="194" data-end="290">★ <strong data-start="196" data-end="230">High cooling performance, compact design</strong><br data-start="230" data-end="233" />Provides effective cooling in hot environments.</p>
<p data-start="292" data-end="385">★ <strong data-start="294" data-end="325">Adjustable airflow function</strong>【*2】<br data-start="329" data-end="332" />Adjust airflow volume to suit the specific work environment.</p>
<p data-start="387" data-end="492">★ <strong data-start="389" data-end="446">Selectable product lines: Collar type and Long-tube type</strong><br data-start="446" data-end="449" />Options available for collar styles (standard and long).</p>
<p data-start="494" data-end="674">★ <strong data-start="496" data-end="536">Heat-resistant and impact-resistant materials</strong><br data-start="536" data-end="539" />Durable materials reduce the unit&#8217;s weight on the body, while the temperature control valve ensures efficient cooling operation.</p>
<p data-start="681" data-end="872"><strong data-start="681" data-end="694">Notes</strong>:<br data-start="695" data-end="698" />【*1】 Uses compressed air available from existing pneumatic systems or cooling air lines.<br data-start="783" data-end="786" />【*2】 The adjustment function allows the user to change air speed and regulate the temperature accordingly.</p>
<h2 data-start="681" data-end="872">Visible Cooling Effectiveness</h2>
<table class="data-table">
<tbody>
<tr>
<th class="header-cyan"><strong>Inlet Air Pressure</strong></th>
<th class="header-cyan"><strong>Air Consumption (L/min)</strong></th>
<th class="header-cyan"><strong>Cool Air Output (L/min)</strong></th>
</tr>
<tr class="row-light-cyan">
<td>0.3 MPa</td>
<td>260 L</td>
<td>Approx. 240 L</td>
</tr>
<tr class="row-light-cyan">
<td>0.4 MPa</td>
<td>340 L</td>
<td>Approx. 310 L</td>
</tr>
<tr class="row-light-cyan">
<td>0.5 MPa</td>
<td>410 L</td>
<td>Approx. 380 L</td>
</tr>
</tbody>
</table>
<p>Values measured with the air adjustment valve set to MAXIMUM (MAX).</p>
<p><strong>Thermal imaging representing body surface temperature</strong></p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56342" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-144101.png" alt="" width="456" height="367" /></td>
<td class="xl65" style="width: 48pt;" rowspan="2" width="64">High temperatures visible in the torso, arms, neck, and head.</td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56343" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-144118.png" alt="" width="409" height="367" /></td>
<td class="xl65" style="width: 48pt;" rowspan="2" width="64">Torso temperature is reduced, and cooling effects are clearly visible in the arms, neck, and head.</td>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><strong>Before use</strong></td>
<td><strong>During use</strong></td>
</tr>
</tbody>
</table>
<h2>Combinable Product Options</h2>
<p><img loading="lazy" decoding="async" class=" wp-image-193351 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-3-300x168.jpg" alt="" width="487" height="273" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-3-300x168.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-3-1024x572.jpg 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-3-768x429.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-3.jpg 1375w" sizes="auto, (max-width: 487px) 100vw, 487px" /></p>The post <a href="https://koueitrading.com/global/product/koken-vp-300-personal-cooling-unit/">Koken VP-300 Personal Cooling Unit</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken FIT-II Qualitative Fit Test Kit</title>
		<link>https://koueitrading.com/global/product/koken-fit-ii-qualitative-fit-test-kit/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Tue, 17 Mar 2020 07:17:37 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=193346</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: FIT-II Koken FIT-II Qualitative Fit Test Kit JIS T 8150:2021 Standard Mandatory Statutory Fit Testing: Required for welding operations【*1】, and Class III management areas【*2】 Uses Sodium Saccharin solution (sweet taste component) Includes 10 test hoods for multi-person testing Features clear labeling to distinguish between sensitivity and fit test solutions ※1 Regulations [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-fit-ii-qualitative-fit-test-kit/">Koken FIT-II Qualitative Fit Test Kit</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: FIT-II</p>
<h2>Koken FIT-II Qualitative Fit Test Kit</h2>
<p data-start="28" data-end="109"><strong>JIS T 8150:2021 Standard</strong></p>
<p data-start="28" data-end="90"><strong>Mandatory Statutory Fit Testing:</strong><br />
Required for welding operations【*1】, and Class III management areas【*2】</p>
<ul>
<li data-start="168" data-end="224">Uses Sodium Saccharin solution (sweet taste component)</li>
<li data-start="227" data-end="288">Includes 10 test hoods for multi-person testing</li>
<li data-start="291" data-end="350">Features clear labeling to distinguish between sensitivity and fit test solutions</li>
</ul>
<p data-start="44" data-end="167">※1 Regulations on fit testing mandated by the Ministry of Health, Labour and Welfare (MHLW Notification No. 286, July 31, 2020).<br />
※2 Statutory fit testing under MHLW Notification No. 91 (effective May 31, 2022; applied from April 2024).</p>
<p data-start="44" data-end="167"><img loading="lazy" decoding="async" class="aligncenter wp-image-56347" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-150034.png" alt="" width="290" height="305" /></p>
<h3 data-start="73" data-end="87"><strong>Kit Contents</strong></h3>
<ol>
<li data-start="91" data-end="126">Test Hoods: 10 units</li>
<li data-start="130" data-end="168">Sensitivity Nebulizer: 1 unit</li>
<li data-start="172" data-end="219">Sensitivity Test Solution: 5ml x 12 bottles</li>
<li data-start="223" data-end="272">Fit Test Nebulizer: 1 unit</li>
<li data-start="276" data-end="334">Fit Test Solution: 5ml x 12 bottles</li>
<li data-start="338" data-end="414">Nebulizer base: 1 unit (can be used as a stand for nebulizers)</li>
</ol>
<h3><strong>Replacement Parts</strong></h3>
<p>◆ <strong>FIT-II Replacement Hoods</strong> (10 hoods): 1<br data-start="490" data-end="493" />◆ <strong>FIT-II Replacement Solution Set</strong>: 3 &amp; 5 (Sensitivity and Fit Test solutions, 12 bottles each)<br data-start="615" data-end="618" />◆ <strong>FIT-II Replacement Nebulizers</strong> (set of 2): 2 &amp; 4 (Includes 2 nebulizers and 2 labels)</p>
<p><strong>Perform your first fit test with confidence!</strong><br />
<strong>Video guides for smooth fit testing procedures</strong></p>
<h3 data-path-to-node="3">VIDEO-GUIDED FIT TESTING</h3>
<p>Easily understand the &#8220;complete fit test sequence,&#8221; ranging from the &#8220;threshold screening test&#8221; (mandatory before qualitative fit testing) to the actual fit test procedure and corrective actions for failed results. The content also explains key points for instructing and training the test subjects.</p>
<h2>Video Content</h2>
<p data-start="74" data-end="112"><strong>Introduction to Fit Testing</strong>:</p>
<ul>
<li data-start="118" data-end="151">Objectives of fit testing.</li>
<li data-start="157" data-end="198">Full fit test workflow.</li>
<li data-start="204" data-end="239">Precautions during the testing process.</li>
</ul>
<p data-start="244" data-end="272"><strong>User Training &amp; Donning</strong>:</p>
<ul>
<li data-start="278" data-end="312">Pre-use inspection of the mask.</li>
<li data-start="318" data-end="339">Correct donning techniques.</li>
<li data-start="345" data-end="384">User seal check methods (positive/negative pressure).</li>
</ul>
<p data-start="345" data-end="384"><strong>Statutory Fit Test Execution</strong>:</p>
<ul>
<li data-start="429" data-end="474">Taste threshold screening method.</li>
<li data-start="480" data-end="520">Step-by-step fit test protocol.</li>
<li data-start="526" data-end="567">Guidance for failed test results.</li>
</ul>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19">
<p data-start="47" data-end="69"><strong>1) Normal Breathing</strong></p>
<ul data-start="71" data-end="216">
<li data-start="71" data-end="131">
<p data-start="73" data-end="131">Subject stands still and breathes normally as if in a typical work setting.</p>
</li>
<li data-start="133" data-end="216">
<p data-start="135" data-end="154">During the test: Subject breathes through the mouth and confirms no sweet taste is detected.</p>
</li>
</ul>
<p data-start="218" data-end="249"><strong>Duration: 1 minute</strong></p>
</td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56348" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-151025.png" alt="" width="315" height="262" /></td>
</tr>
</tbody>
</table>
<p>Video: Performing the Fit Test</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19">Pass Criteria: Fit Factor must reach 100 or higher</td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56349" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-151107.png" alt="" width="245" height="223" /></td>
</tr>
</tbody>
</table>
<p>Video: Assessment guidance and troubleshooting for failed tests</p>The post <a href="https://koueitrading.com/global/product/koken-fit-ii-qualitative-fit-test-kit/">Koken FIT-II Qualitative Fit Test Kit</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken 1005 Series Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-1005-series-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Tue, 17 Mar 2020 06:52:18 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=193335</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: 1005 Series Important points when wearing a mask Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself from inhaling dust while wearing a dust mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical. [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-1005-series-dust-mask/">Koken 1005 Series Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: 1005 Series</p>
<h2>Important points when wearing a mask</h2>
<p>Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself from inhaling dust while wearing a dust mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Using unique technology, wool fibers are electrostatically charged, allowing electrostatic force to draw particles to the fiber surface. This is the primary mechanism for capturing particles. A high-density fiber structure is unnecessary, successfully integrating the two contrasting features: &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221; It consistently maintains the highest standard of performance and quality, making it an excellent long-term filter solution.</p>
<table style="border-collapse: collapse; width: 640px; height: 264px;" border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applied products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the fiber density of the filter enhances collection efficiency. To meet airflow resistance standards, paper filters traditionally require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into pristine circular shapes in a single process, creating the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table style="border-collapse: collapse; width: 641px; height: 304px;" border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" alt="" width="329" height="127" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applied products are from page P.8 to P.11</p>
<p data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<th style="height: 14.4pt; width: 48pt;" width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td style="width: 48pt;" width="64">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the &#8220;Dust Respirator Standards&#8221;.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" style="width: 45%;" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct-Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table" style="font-size: 12px;">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Particles</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ /min</td>
<td class="text-center" colspan="2">85 ℓ /min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement; must meet values in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" style="font-size: 12px;" colspan="2">For NaCl test aerosol<br />
Load up to 100mg</td>
<td class="text-left" style="font-size: 12px;" colspan="2">For DOP test aerosol<br />
Load up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or higher</td>
<td>RL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or higher</td>
<td>RL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or higher</td>
<td>RL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or higher</td>
<td>DL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or higher</td>
<td>DL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or higher</td>
<td>DL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" style="text-align: center;" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" style="text-align: center;" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" style="text-align: center;" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" style="text-align: center;" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>( ) indicates products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col" style="width: 25%;">Exhalation valve operation leak test</td>
<td>&#8211; When air is drawn, the internal pressure must decrease immediately<br />
&#8211; The time for internal pressure to return to normal atmospheric pressure must be 15 seconds or more</td>
</tr>
<tr>
<th class="header-col"><strong>Carbon Dioxide (CO2) Concentration Increase</strong></th>
<td class="content-col" colspan="2">Using a test headform and an artificial lung to inhale/exhale air containing CO2. The difference in CO2 concentration in the inhaled air between wearing and not wearing the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space Volume</strong></th>
<td class="content-col" colspan="2">Value calculated from the (Carbon Dioxide Concentration Increase Test)</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Aerosol</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">Measured at 40 ℓ/min after loading test dust at 85 ℓ/min</td>
</tr>
<tr>
<td class="header-sub">Amount loaded onto dust respirator</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test aerosol and collection efficiency </span><span class="bottom-left-text">Disposable Type<br />
／Replaceable Type</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" style="width: 25%;" rowspan="2"><strong>Classification</strong><br />
<strong>(Collection efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender" style="font-weight: normal; font-size: 12px;"><strong>Test aerosol is</strong><br />
<strong>Solid Sodium Chloride (NaCl)</strong></th>
<th class="bg-lavender" style="font-weight: normal; font-size: 12px;"><strong>Test aerosol is</strong><br />
<strong>Liquid Dioctyl</strong><br />
<strong>Phthalate (DOP)</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (Above 80.0%)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (Above 95.0%)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (Above 99.9%)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (Above 80.0%)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (Above 95.0%)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (Above 99.9%)</td>
</tr>
</tbody>
</table>
<h2>High Efficiency Filter + Ergonomic Face Seal</h2>
<h3>2. Facepiece Fit Technology</h3>
<p>Even if a dust mask has a high collection efficiency filter, it is ineffective if dust leaks through the facepiece seal during use. The primary cause of exposure is the &#8220;gap at the facial contact area.&#8221; We consider mask fit to be just as important as filter performance. Therefore, our company developed technology to enhance the airtightness of the facial contact area early on.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" alt="" width="247" height="326" /><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and effortlessly adapts to facial movements, ensuring a comfortable fit and stability during use.</p>
<p><strong>HAWC harness strap</strong><br />
The strap design ensures a high level of fit, maximizing the &#8220;suction&#8221; effect when wearing the mask to ensure an airtight seal on the face. <img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" alt="" width="145" height="163" /></p>
<p><strong>Freeposition Underchin</strong><br />
The unique curve of the facial contact area prevents dust entry. The nose section is aligned first, allowing it to accommodate various facial dimensions and providing a secure fit for a wide range of face sizes (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" alt="" width="192" height="115" /></p>
<p><strong data-start="56" data-end="112">Fit Status of the Freeposition Underchin Facepiece</strong><br data-start="112" data-end="115" />(Cross-sectional simulation to show the contact position between the mask and the chin).</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><strong data-start="56" data-end="94">For large faces:</strong><br data-start="94" data-end="97" />Uses the outer section of the mask to adjust the fit around the chin.</td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td style="width: 48pt;" width="64"><strong data-start="164" data-end="202">For small faces:</strong><br data-start="202" data-end="205" />Uses the inner section of the mask to adjust the fit around the chin.</td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr style="height: 14.4pt;">
<th class="xl65" style="height: 14.4pt; width: 96pt;" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" style="width: 96pt;" colspan="2" width="128"><strong>Wearing Stability</strong></th>
<th class="xl65" style="width: 96pt;" colspan="2" width="128"><strong>Internal Fit Checker</strong></th>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed for various face shapes; the cushion naturally fits your face.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Utilizes a 3D poly-band harness that matches head shapes to enhance fit and seal.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>Fit checker is integrated inside, helping to check the mask seal at any time (available for models 1005, 1010A, 1015, 1180 series).</td>
</tr>
</tbody>
</table>
<h2>Replaceable Dust Mask<br data-start="54" data-end="57" />Mighty Micron Filter</h2>
<p data-start="27" data-end="97"><strong data-start="27" data-end="97">The yellow filter is the hallmark<br data-start="66" data-end="69" />Mighty Micron Filter</strong></p>
<p data-start="99" data-end="454">Thanks to proprietary technology, this filter is created by electrostatically charging the base wool fiber material. In addition to a strong electrostatic force, a 3-layer structure with a void space between two collection layers achieves low fiber density while combining two opposing characteristics: high collection efficiency and low inhalation resistance.</p>
<p data-start="99" data-end="454"><img loading="lazy" decoding="async" class="aligncenter wp-image-56369" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/1.png" alt="" width="659" height="295" /></p>
<ul>
<li data-start="24" data-end="136">Fit checker: Perform a seal test (fit test) simply by operating a lever.</li>
<li data-start="139" data-end="241">Under-chin: Unique curve design enhances the seal at the facial contact area.</li>
<li data-start="244" data-end="335">Silicone: Uses soft, skin-friendly silicone for a comfortable wearing experience.</li>
<li data-start="338" data-end="405">Size S available: Small face size options are available for these models.</li>
<li data-start="408" data-end="497">Micron: Employs high-performance electrostatic filters compliant with RL classifications.</li>
</ul>
<h4 data-start="27" data-end="81"><strong>Sakai – Model 1005R-08</strong></h4>
<p data-start="27" data-end="81">Integrated Fit Checker – Suitable for welding operations</p>
<p data-start="111" data-end="182">Model Assay Certificate: TM540<br data-start="150" data-end="153" />Assigned Protection Factor: 10<br />
Classification: RL2</p>
<p data-start="111" data-end="182"><img loading="lazy" decoding="async" class="aligncenter wp-image-56370" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-102456.png" alt="" width="274" height="267" /></p>
<ul>
<li data-start="48" data-end="102">Fit Checker (Integrated seal check lever)</li>
<li data-start="105" data-end="147">Under-chin support</li>
<li data-start="150" data-end="176">Silicone seal</li>
<li data-start="179" data-end="206">Size S available</li>
<li data-start="209" data-end="230">Micron Filter</li>
</ul>
<table class="spec-table">
<tbody>
<tr>
<th class="col-label"><strong>Collection Efficiency</strong></th>
<td class="col-limit">95.0% or higher</td>
<td class="col-avg">(Average 99.1%)</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-limit">75Pa or less</td>
<td class="col-avg">(Average 58Pa)</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-limit">52Pa or less</td>
<td class="col-avg">(Average 31Pa)</td>
</tr>
<tr>
<th class="col-label"><strong>Resistance Increase</strong></th>
<td class="col-limit">―</td>
<td class="col-avg">(Average 68Pa)</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-limit">155g or less</td>
<td class="col-avg">(Average 143g)</td>
</tr>
<tr>
<th class="col-label"><strong>Harness</strong></th>
<td style="text-align: left;">RB Type</td>
<td class="col-avg"></td>
</tr>
</tbody>
</table>
<h4 data-start="27" data-end="122">Sakai – Model 1005RR-05</h4>
<p data-start="27" data-end="122">Compatible with KBC filter for ozone and organic odor removal<br data-start="95" data-end="98" />Integrated Fit Checker</p>
<p data-start="151" data-end="222">Model Assay Certificate: TM541<br data-start="190" data-end="193" />Assigned Protection Factor: 10</p>
<p data-start="224" data-end="278">Compatible with KBC filter<br data-start="257" data-end="260" />Classification: RL2</p>
<p data-start="224" data-end="278"><img loading="lazy" decoding="async" class="aligncenter wp-image-56371" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-102831.png" alt="" width="275" height="265" /></p>
<ul>
<li data-start="48" data-end="102">Fit Checker</li>
<li data-start="105" data-end="147">Under-chin support</li>
<li data-start="150" data-end="176">Silicone seal</li>
<li data-start="179" data-end="206">Size S available</li>
<li data-start="209" data-end="230">Micron Filter</li>
</ul>
<table class="spec-table">
<tbody>
<tr>
<th class="col-label"><strong>Collection Efficiency</strong></th>
<td class="col-limit">95.0% or higher</td>
<td class="col-avg">(Average 99.0%)</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-limit">73Pa or less</td>
<td class="col-avg">(Average 56Pa)</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-limit">52Pa or less</td>
<td class="col-avg">(Average 31Pa)</td>
</tr>
<tr>
<th class="col-label"><strong>Resistance Increase</strong></th>
<td class="col-limit">―</td>
<td class="col-avg">(Average 66Pa)</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-limit">157g or less</td>
<td class="col-avg">(Average 145g)</td>
</tr>
<tr>
<th class="col-label"><strong>Harness</strong></th>
<td style="text-align: left;">RB Type</td>
<td style="text-align: left;"></td>
</tr>
</tbody>
</table>
<h4 data-start="27" data-end="132">Sakai – Model 1005R-AL-02</h4>
<p data-start="27" data-end="132">Suitable for environments with radiant heat<br data-start="81" data-end="84" />Aluminized coating<br data-start="105" data-end="108" />Integrated Fit Checker</p>
<p data-start="163" data-end="234">Model Assay Certificate: TM543<br data-start="202" data-end="205" />Assigned Protection Factor: 10</p>
<p data-start="236" data-end="254">Classification: RL2</p>
<p data-start="236" data-end="254"><img loading="lazy" decoding="async" class="aligncenter wp-image-56372" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-103226.png" alt="" width="274" height="273" /></p>
<ul>
<li data-start="48" data-end="102">Fit Checker</li>
<li data-start="105" data-end="147">Under-chin support</li>
<li data-start="150" data-end="176">Silicone seal</li>
<li data-start="179" data-end="206">Size S available</li>
<li data-start="209" data-end="230">Micron Filter</li>
</ul>
<table class="spec-table">
<tbody>
<tr>
<th class="col-label"><strong>Collection Efficiency</strong></th>
<td class="col-limit">95.0% or higher</td>
<td class="col-avg">(Average 98.9%)</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-limit">75Pa or less</td>
<td class="col-avg">(Average 58Pa)</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-limit">52Pa or less</td>
<td class="col-avg">(Average 29Pa)</td>
</tr>
<tr>
<th class="col-label"><strong>Resistance Increase</strong></th>
<td class="col-limit">―</td>
<td class="col-avg">(Average 70Pa)</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-limit">165g or less</td>
<td class="col-avg">(Average 143g)</td>
</tr>
<tr>
<th class="col-label"><strong>Harness</strong></th>
<td style="text-align: left;">RB Type</td>
<td style="text-align: left;"></td>
</tr>
</tbody>
</table>
<h4 data-start="27" data-end="152">Sakai – Model 1005RRX-05</h4>
<p data-start="27" data-end="152">Compatible with KBC filter for ozone and organic odor removal<br data-start="99" data-end="102" />Integrated Fit Checker<br data-start="126" data-end="129" />4-point head harness</p>
<p data-start="182" data-end="253">Model Assay Certificate: TM542<br data-start="221" data-end="224" />Assigned Protection Factor: 10</p>
<p data-start="255" data-end="309">Compatible with KBC filter<br data-start="288" data-end="291" />Classification: RL2</p>
<p data-start="255" data-end="309"><img loading="lazy" decoding="async" class="aligncenter wp-image-56373" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-103419.png" alt="" width="274" height="260" /></p>
<ul>
<li data-start="48" data-end="102">Fit Checker</li>
<li data-start="105" data-end="147">Under-chin support</li>
<li data-start="150" data-end="176">Silicone seal</li>
<li data-start="179" data-end="206">Size S available</li>
<li data-start="209" data-end="230">Micron Filter</li>
</ul>
<table class="spec-table">
<tbody>
<tr>
<th class="col-label"><strong>Collection Efficiency</strong></th>
<td class="col-limit">95.0% or higher</td>
<td class="col-avg">(Average 99.0%)</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-limit">73Pa or less</td>
<td class="col-avg">(Average 55Pa)</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-limit">52Pa or less</td>
<td class="col-avg">(Average 30Pa)</td>
</tr>
<tr>
<th class="col-label"><strong>Resistance Increase</strong></th>
<td class="col-limit">―</td>
<td class="col-avg">(Average 66Pa)</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-limit">168g or less</td>
<td class="col-avg">(Average 155g)</td>
</tr>
<tr>
<th class="col-label"><strong>Harness</strong></th>
<td style="text-align: left;">XRB Type</td>
<td style="text-align: left;"></td>
</tr>
</tbody>
</table>
<p data-start="22" data-end="74"><strong data-start="22" data-end="72">▲ Shared Replacement Parts for 1005 Series</strong></p>
<ul>
<li data-start="77" data-end="111">Inhalation Valve (Circular)</li>
<li data-start="114" data-end="138">Exhalation Valve (T-6K)</li>
<li data-start="141" data-end="179">Moisture Sponge (Egg-shaped)</li>
</ul>
<h4>Replacement Filters · Optional Accessories</h4>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56374" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-103919.png" alt="" width="416" height="173" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56375" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-103926.png" alt="" width="406" height="176" /></td>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19">Mighty Micron Filter for 1005-02</td>
<td>KBC Filter for 1005 (Ozone &amp; organic odor removal, 5 sets/pack) (Optional)<br data-start="116" data-end="119" />→ For 1005RR / 1005RRX</td>
</tr>
</tbody>
</table>
<p><strong data-start="31" data-end="57">（Head Harness Types）</strong><br data-start="57" data-end="60" />Please replace the head straps periodically.</p>
<p><img loading="lazy" decoding="async" class="size-medium wp-image-193333 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-1-2-300x189.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-1-2-300x189.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-1-2-768x484.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-1-2.jpg 1024w" alt="" width="300" height="189" /></p>
<h3 data-start="81" data-end="139"><strong data-start="85" data-end="139">Collection Efficiency with DOP Particles (using 1005R)</strong></h3>
<p><img loading="lazy" decoding="async" class=" wp-image-193342 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-3-2-300x195.jpg" alt="" width="355" height="231" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-3-2-300x195.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-3-2-768x500.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-3-2-180x118.jpg 180w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-3-2.jpg 1024w" sizes="auto, (max-width: 355px) 100vw, 355px" /></p>
<p data-start="141" data-end="400">Up to a load of 200 mg of DOP particles, the minimum collection efficiency was 98.74%. Even for DOP particles—which tend to degrade electrostatic forces faster than other oil mists—the Mighty Micron filter maintains very high performance.</p>
<h3 data-start="407" data-end="480"><strong data-start="411" data-end="480">Collection Efficiency against Welding Fume (30 mg/m³) – using 1005R</strong></h3>
<p><img loading="lazy" decoding="async" class=" wp-image-193343 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-2-300x181.jpg" alt="" width="356" height="215" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-2-300x181.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-2-768x463.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-2.jpg 1024w" sizes="auto, (max-width: 356px) 100vw, 356px" /></p>
<p data-start="482" data-end="769">During the accumulation of 100 mg of welding fume, the minimum collection efficiency was 99.927%. After this, the mechanical sieving effect becomes dominant, maintaining extremely high efficiency. → Efficiency at 100 mg load: 99.993%.</p>
<h2 data-start="67" data-end="133"><strong>Built-in Fit Checker – Rapid Seal Verification</strong></h2>
<p data-start="135" data-end="444">Regardless of filter efficiency, a mask provides no protection if not worn correctly. For this reason, national regulations require replaceable dust masks to have an easy method for fit testing.<br />
Our company was the first in Japan to develop an integrated fit checker, allowing for simpler seal checks. There is no need for external testing equipment; users can verify the fit instantly on-site.<br />
This design encourages workers to perform seal checks every time they don the mask, ensuring consistent safety.</p>
<p data-start="916" data-end="981"><strong>Applicable Series:</strong><br data-start="941" data-end="944" />1005 series, 1010A, 1015, 1180 series</p>
<p data-start="916" data-end="981"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56377" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-105132.png" alt="" width="251" height="324" /> <img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56378" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-105145.png" alt="" width="249" height="325" /></p>
<p data-start="916" data-end="981">Simply move the lever to close the inhalation port and perform a negative pressure seal check.</p>
<h4 data-start="26" data-end="158">Sakai Model 1010A-06</h4>
<p data-start="26" data-end="158">RL1 Rating<br data-start="33" data-end="36" />Integrated Fit Checker<br data-start="81" data-end="84" />Lightest in class: 76 g (compared to other replaceable filter models from Koken)</p>
<p data-start="160" data-end="256">Model Assay Certificate: TM560<br data-start="225" data-end="228" />Assigned Protection Factor: 4</p>
<p data-start="160" data-end="256"><img loading="lazy" decoding="async" class="aligncenter wp-image-56382" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-105843.png" alt="" width="227" height="231" /></p>
<ul>
<li data-start="28" data-end="80">Fit Checker</li>
<li data-start="83" data-end="117">Mighty Micron Filter</li>
</ul>
<table>
<tbody>
<tr>
<th class="label-col"><strong>Collection Efficiency</strong></th>
<td class="value-col">80.0% or higher<br />
(Average 94.4%)</td>
</tr>
<tr>
<th class="label-col"><strong>Inhalation Resistance</strong></th>
<td class="value-col">70Pa or less<br />
(Average 59Pa)</td>
</tr>
<tr>
<th class="label-col"><strong>Exhalation Resistance</strong></th>
<td class="value-col">63Pa or less<br />
(Average 38Pa)</td>
</tr>
<tr>
<th class="label-col"><strong>Resistance Increase</strong></th>
<td class="value-col">―<br />
(Average 109Pa)</td>
</tr>
<tr>
<th class="label-col"><strong>Weight</strong></th>
<td class="value-col">83g or less<br />
(Average 76g)</td>
</tr>
<tr>
<th class="label-col"><strong>Harness</strong></th>
<td class="value-col">RB Type</td>
</tr>
</tbody>
</table>
<p><strong>Replacement Parts</strong></p>
<ul>
<li data-start="63" data-end="106">Inhalation Valve – Oval type (Small)</li>
<li data-start="109" data-end="147">Exhalation Valve – T-6K type</li>
<li data-start="150" data-end="199">Moisture Sponge – Egg-shaped</li>
</ul>
<h4 data-start="263" data-end="319">Sakai Model 1015-02</h4>
<p data-start="263" data-end="319">RL2 Rating<br data-start="270" data-end="273" />Integrated Fit Checker<br data-start="297" data-end="300" />Silicone Facepiece</p>
<p data-start="321" data-end="417" data-is-last-node="" data-is-only-node="">Model Assay Certificate: TM570<br data-start="385" data-end="388" />Assigned Protection Factor: 10</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56383" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-105905.png" alt="" width="226" height="236" /></p>
<ul>
<li data-start="134" data-end="183">Fit Checker</li>
<li data-start="186" data-end="230">Freeposition Underchin design</li>
<li data-start="233" data-end="259">Silicone seal</li>
<li data-start="262" data-end="286">Mighty Micron Filter</li>
</ul>
<div class="table-title">
<table class="spec-table">
<tbody>
<tr>
<th class="label-col"><strong>Collection Efficiency</strong></th>
<td class="value-col">95.0% or higher<br />
(Average 98.6%)</td>
</tr>
<tr>
<th class="label-col"><strong>Inhalation Resistance</strong></th>
<td class="col-value">80Pa or less<br />
(Average 66Pa)</td>
</tr>
<tr>
<th class="label-col"><strong>Exhalation Resistance</strong></th>
<td class="col-value">60Pa or less<br />
(Average 28Pa)</td>
</tr>
<tr>
<th class="label-col"><strong>Resistance Increase</strong></th>
<td class="col-value">―<br />
(Average 107Pa)</td>
</tr>
<tr>
<th class="label-col"><strong>Weight</strong></th>
<td class="col-value">129g or less<br />
(Average 113g)</td>
</tr>
<tr>
<th class="label-col"><strong>Harness</strong></th>
<td class="col-value">RB Type</td>
</tr>
</tbody>
</table>
</div>
<p><strong>Replacement Parts</strong></p>
<ul>
<li data-start="352" data-end="393">Inhalation Valve (Oval small type)</li>
<li data-start="396" data-end="432">Exhalation Valve (T-6K type)</li>
<li data-start="435" data-end="481">Moisture Sponge (Egg-shaped)</li>
</ul>The post <a href="https://koueitrading.com/global/product/koken-1005-series-dust-mask/">Koken 1005 Series Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken 1021 Series And 1091D-04 Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-1021-series-and-1091d-04-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Tue, 17 Mar 2020 06:34:39 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=193328</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: 1021 Series and 1091D-04 Important points when wearing a mask Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself while wearing a dust mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical. 1. [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-1021-series-and-1091d-04-dust-mask/">Koken 1021 Series And 1091D-04 Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: 1021 Series and 1091D-04</p>
<h2>Important points when wearing a mask</h2>
<p>Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself while wearing a dust mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<h4><strong>Mighty (Uni) Micron Filter</strong></h4>
<p>Using unique technology, wool fibers are electrostatically charged, allowing electrostatic force to draw particles to the fiber surface. This is the primary mechanism for capturing particles. A high-density fiber structure is unnecessary, successfully integrating the two contrasting features: &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221; It consistently maintains the highest standard of performance and quality, making it an excellent long-term filter solution.</p>
<table style="border-collapse: collapse; width: 640px; height: 264px;" border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applied products are on P.4 ~ 6, P.11</p>
<h4><strong>Alpha Ring Filter</strong></h4>
<p data-start="57" data-end="197">Increasing the fiber density of the filter enhances collection efficiency. To meet airflow resistance standards, paper filters traditionally require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into pristine circular shapes in a single process, creating the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table style="border-collapse: collapse; width: 641px; height: 304px;" border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" alt="" width="329" height="127" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applied products are from page P.8 to P.11</p>
<h4 data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></h4>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<th style="height: 14.4pt; width: 48pt;" width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td style="width: 48pt;" width="64">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the &#8220;Dust Respirator Standards&#8221;.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" style="width: 45%;" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct-Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table" style="font-size: 12px;">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Particles</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride) particles</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate) particles</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ /min</td>
<td class="text-center" colspan="2">85 ℓ /min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement; must meet values in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" style="font-size: 12px;" colspan="2">For NaCl test aerosol<br />
Loaded up to 100mg</td>
<td class="text-left" style="font-size: 12px;" colspan="2">For DOP test aerosol<br />
Loaded up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or higher</td>
<td>RL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or higher</td>
<td>RL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or higher</td>
<td>RL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or higher</td>
<td>DL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or higher</td>
<td>DL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or higher</td>
<td>DL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" style="text-align: center;" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" style="text-align: center;" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" style="text-align: center;" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" style="text-align: center;" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>( ) indicates products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col" style="width: 25%;">Exhalation valve operation leak test</td>
<td>&#8211; When air is drawn, the internal pressure must decrease immediately<br />
&#8211; The time for internal pressure to return to normal atmospheric pressure must be 15 seconds or more</td>
</tr>
<tr>
<th class="header-col"><strong>Carbon Dioxide (CO2) Concentration Increase</strong></th>
<td class="content-col" colspan="2">Using a test headform and an artificial lung to inhale/exhale air containing CO2. The difference in CO2 concentration in the inhaled air between wearing and not wearing the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space Volume</strong></th>
<td class="content-col" colspan="2">Value calculated from the (Carbon Dioxide Concentration Increase Test)</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Particles</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">Measured at 40 ℓ/min after loading test dust at 85 ℓ/min</td>
</tr>
<tr>
<td class="header-sub">Amount loaded onto dust respirator</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test aerosol and collection efficiency </span><span class="bottom-left-text">Disposable Type<br />
／Replaceable Type</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" style="width: 25%;" rowspan="2"><strong>Classification</strong><br />
<strong>(Collection efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender" style="font-weight: normal; font-size: 12px;"><strong>Test aerosol is</strong><br />
<strong>Solid Sodium Chloride (NaCl)</strong></th>
<th class="bg-lavender" style="font-weight: normal; font-size: 12px;"><strong>Test aerosol is</strong><br />
<strong>Liquid Dioctyl</strong><br />
<strong>Phthalate (DOP)</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (Above 80.0%)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (Above 95.0%)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (Above 99.9%)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (Above 80.0%)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (Above 95.0%)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (Above 99.9%)</td>
</tr>
</tbody>
</table>
<h2>High Efficiency Filter + Ergonomic Face Seal</h2>
<h3>2. Facepiece Fit Technology</h3>
<p>Even if a dust mask has a high collection efficiency filter, it is ineffective if dust leaks through the facepiece seal during use. This is primarily caused by a &#8220;gap at the facial contact area.&#8221; We consider mask fit to be as important as filter performance. Therefore, our company has long developed technology to enhance the airtightness of the facial contact area.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" alt="" width="247" height="326" /><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and effortlessly adapts to facial movements, ensuring a comfortable fit. The material is also stable during use.</p>
<p><strong>HAWC harness strap</strong><br />
The strap design ensures a high level of fit, maximizing the &#8220;suction&#8221; effect when wearing the mask to ensure an airtight facial seal. <img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" alt="" width="145" height="163" /></p>
<p><strong>Freeposition Underchin</strong><br />
The unique curve of the facial contact area prevents dust entry. The nose section is aligned first, allowing it to accommodate various facial dimensions and providing a secure fit for a wide range of face sizes (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" alt="" width="192" height="115" /></p>
<p><strong data-start="56" data-end="112">Fit Status of the Freeposition Underchin Facepiece</strong><br data-start="112" data-end="115" />(Cross-sectional simulation to show the contact position between the mask and the chin).</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><strong data-start="56" data-end="94">For large faces:</strong><br data-start="94" data-end="97" />Uses the outer section of the mask to adjust the fit around the chin.</td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td style="width: 48pt;" width="64"><strong data-start="164" data-end="202">For small faces:</strong><br data-start="202" data-end="205" />Uses the inner section of the mask to adjust the fit around the chin.</td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr style="height: 14.4pt;">
<th class="xl65" style="height: 14.4pt; width: 96pt;" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" style="width: 96pt;" colspan="2" width="128"><strong>Wearing Stability</strong></th>
<th class="xl65" style="width: 96pt;" colspan="2" width="128"><strong>Internal Fit Checker</strong></th>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed for various face shapes; the cushion naturally fits your face.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Utilizes a 3D poly-band harness that matches head shapes to enhance fit and seal.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>Fit checker is integrated inside, allowing for seal checks at any time (available for models 1005, 1010A, 1015, 1180 series).</td>
</tr>
</tbody>
</table>
<h2 data-start="111" data-end="182">Replaceable Dust Mask<br data-start="98" data-end="101" />Mighty Micron Filter</h2>
<p><strong data-start="31" data-end="57">（Head Harness Types）</strong><br data-start="57" data-end="60" />Please replace the head straps periodically.</p>
<p><img loading="lazy" decoding="async" class="size-medium wp-image-193333 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-1-2-300x189.jpg" alt="" width="300" height="189" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-1-2-300x189.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-1-2-768x484.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-1-2.jpg 1024w" sizes="auto, (max-width: 300px) 100vw, 300px" /></p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56388" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-111728.png" alt="" width="249" height="333" /></p>
<h3 data-start="31" data-end="117"><strong data-start="31" data-end="117">Koken’s Unique Facial Seal – Extreme Focus on Fit</strong></h3>
<p><strong data-start="123" data-end="136">Shape (</strong><strong data-start="139" data-end="177">Freeposition Underchin Mask)</strong></p>
<p data-start="179" data-end="523">The “Freeposition Underchin Mask” allows the user, when donning, to first set the nose portion in the correct position. The underchin support then automatically settles into place, achieving an optimal wrap-around fit. Regardless of face size, almost anyone can achieve a secure seal and soft wearing feel with just one mask size.</p>
<p><strong data-start="529" data-end="541">Material (</strong><strong data-start="544" data-end="577">Silicone – Flexible and Stable)</strong></p>
<p data-start="579" data-end="891" data-is-last-node="" data-is-only-node="">Silicone material is hypoallergenic and unlikely to cause skin dryness. It remains flexible according to facial expressions, ensuring stable and comfortable wear. Additionally, it is highly resistant to skin oils and easy to clean, making it suitable for long-term use in professional environments.</p>
<h3>Features</h3>
<ul>
<li data-start="28" data-end="145">Under-chin design: Enhanced seal at the facial contact points due to specialized curvature.</li>
<li data-start="149" data-end="272">Silicone: Soft, skin-friendly material for a comfortable wearing experience.</li>
<li data-start="276" data-end="360">Size S available: Size options for individuals with smaller facial dimensions.</li>
<li data-start="364" data-end="487">Speaking Diaphragm: Enables clear verbal communication and commands while wearing the mask.</li>
<li data-start="491" data-end="606">Micron: Employs high-performance electrostatic filters compliant with RL classifications.</li>
</ul>
<h3>Sakai Model 1021R-07</h3>
<p data-start="26" data-end="112">RL2 Rating<br data-start="33" data-end="36" />Low-profile filter design ensures a clear downward field of vision.<br />
Type Certification: TM545<br />
Assigned Protection Factor: 10</p>
<p data-start="217" data-end="247">Compatible with KBC filters</p>
<p data-start="217" data-end="247"><img loading="lazy" decoding="async" class="aligncenter wp-image-56390" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-112326-1.png" alt="" width="287" height="240" /></p>
<ul>
<li data-start="276" data-end="300">Under-chin Seal</li>
<li data-start="303" data-end="322">Silicone Facepiece</li>
<li data-start="325" data-end="338">Size S Available</li>
<li data-start="341" data-end="358">Micron Filter</li>
</ul>
<table class="spec-table">
<tbody>
<tr>
<th class="label-col" style="width: 50%;"><strong>Particle Collection Efficiency</strong></th>
<td class="value-col">95.0% or higher<br />
(Average 98.0%)</td>
</tr>
<tr>
<th class="label-col"><strong>Inhalation Resistance</strong></th>
<td class="value-col">80Pa or less<br />
(Average 51Pa)</td>
</tr>
<tr>
<th class="label-col"><strong>Exhalation Resistance</strong></th>
<td class="value-col">52Pa or less<br />
(Average 29Pa)</td>
</tr>
<tr>
<th class="label-col"><strong>Resistance Increase</strong></th>
<td class="value-col">―<br />
(Average 87Pa)</td>
</tr>
<tr>
<th class="label-col"><strong>Weight</strong></th>
<td class="value-col">160g or less<br />
(Average 149g)</td>
</tr>
<tr>
<th class="label-col"><strong>Head Harness</strong></th>
<td class="value-col">RB Type</td>
</tr>
</tbody>
</table>
<p>Replacement Parts: Exhalation Valve – T-6K type</p>
<h3>Sakai Model 1021RX-05</h3>
<p data-start="26" data-end="83">RL2 Rating<br data-start="33" data-end="36" />4-point head harness prevents mask shifting</p>
<p>Type Certification: TM546<br />
Assigned Protection Factor: 10</p>
<p data-start="184" data-end="217">Compatible with KBC filters</p>
<p data-start="184" data-end="217"><img loading="lazy" decoding="async" class="aligncenter wp-image-56391" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-112645.png" alt="" width="289" height="243" /></p>
<ul>
<li data-start="248" data-end="273">Under-chin Seal</li>
<li data-start="276" data-end="308">Silicone Facepiece</li>
<li data-start="311" data-end="326">Size S Available</li>
<li data-start="329" data-end="362">Micron Filter</li>
</ul>
<div class="spec-table-container">
<table class="spec-table">
<tbody>
<tr>
<th class="label-col" style="width: 50%;"><strong>Particle Collection Efficiency</strong></th>
<td class="value-col">95.0% or higher<br />
(Average 98.0%)</td>
</tr>
<tr>
<th class="label-col"><strong>Inhalation Resistance</strong></th>
<td class="value-col">80Pa or less<br />
(Average 53Pa)</td>
</tr>
<tr>
<th class="label-col"><strong>Exhalation Resistance</strong></th>
<td class="value-col">52Pa or less<br />
(Average 29Pa)</td>
</tr>
<tr>
<th class="label-col"><strong>Resistance Increase</strong></th>
<td class="value-col">―<br />
(Average 86Pa)</td>
</tr>
<tr>
<th class="label-col"><strong>Weight</strong></th>
<td class="value-col">163g or less<br />
(Average 154g)</td>
</tr>
<tr>
<th class="label-col"><strong>Head Harness</strong></th>
<td class="value-col">XRB Type</td>
</tr>
</tbody>
</table>
</div>
<p>Replacement Parts: Exhalation Valve – T-6K type</p>
<h3>Sakai Model 1091D-04</h3>
<p data-start="26" data-end="150">RL2 Rating<br data-start="33" data-end="36" />4-point harness with integrated speaking diaphragm<br data-start="71" data-end="74" />Facilitates verbal communication and instructions while wearing the mask.</p>
<p>Type Certification: TM548<br />
Assigned Protection Factor: 10</p>
<p data-start="257" data-end="292">Compatible with KBC filters</p>
<p data-start="257" data-end="292"><img loading="lazy" decoding="async" class="aligncenter wp-image-56392" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-113208.png" alt="" width="294" height="238" /></p>
<ul>
<li data-start="325" data-end="350">Under-chin Seal</li>
<li data-start="353" data-end="385">Silicone Facepiece</li>
<li data-start="388" data-end="406">Speaking Diaphragm</li>
<li data-start="409" data-end="423">Micron Filter</li>
</ul>
<div class="table-container">
<table>
<tbody>
<tr>
<th class="col-label" style="width: 50%;"><strong>Particle Collection Efficiency</strong></th>
<td class="col-value">95.0% or higher<br />
(Average 98.1%)</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-value">80Pa or less<br />
(Average 55Pa)</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-value">35Pa or less<br />
(Average 17Pa)</td>
</tr>
<tr>
<th class="col-label"><strong>Resistance Increase</strong></th>
<td class="col-value">―<br />
(Average 85Pa)</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-value">178g or less<br />
(Average 173g)</td>
</tr>
<tr class="last-data-row">
<th class="col-label"><strong>Head Harness</strong></th>
<td class="col-value">XRB Type</td>
</tr>
</tbody>
</table>
</div>
<p><span class="blue-dot">*</span>The Model 1091SD-03 is also available with an RB-type head harness.<br />
Replacement Parts: Exhalation Valve T-1 (T-1 type)</p>
<h4><strong data-start="26" data-end="43">4-Point Support</strong><br data-start="43" data-end="46" /><strong data-start="46" data-end="87">XRB Type Head Harness (1021RX / 1091D)</strong></h4>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56393" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-113454.png" alt="" width="159" height="185" /></p>
<p data-start="89" data-end="293" data-is-last-node="" data-is-only-node="">The 4-point harness secures the mask at four locations (top, bottom, left, and right) to contour firmly to the face. Even during work involving heavy head movement, the mask remains stable and maintains a tight seal.</p>
<p data-start="26" data-end="72">▲ Common Replacement Parts for All 3 Models</p>
<ul>
<li data-start="75" data-end="100">Inhalation Valve (Circular)</li>
<li data-start="103" data-end="139">Moisture Sponge (Oval type)</li>
</ul>
<p><strong>Replacement Filters · Optional Accessories</strong></p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56394" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-114327.png" alt="" width="266" height="134" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56395" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-114339.png" alt="" width="254" height="117" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56396" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-114345.png" alt="" width="208" height="128" /></td>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19">Mighty Micron Filter for Model 1021-02</td>
<td>KBC Filter for 1021 / 1091 (Optional)<br data-start="267" data-end="270" />Ozone and organic odor removal (5 sets per pack)<br data-start="316" data-end="319" />Applicable models: 1021R / 1021RX / 1091D</td>
<td>Fit Tester Type F (Optional)<br data-start="477" data-end="480" />Left &amp; Right Set</td>
</tr>
</tbody>
</table>
<h2>Related Protective Equipment</h2>
<h3><strong>Dust Safety Goggles</strong><br />
Prevent eye injury caused by particulates.</h3>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56397" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-114911.png" alt="" width="340" height="245" /></p>
<p><strong>Sakai Model KR-11</strong></p>
<p data-start="48" data-end="515">These are goggle-style safety glasses designed for easy combination with our half-face dust masks. Equipped with high-performance ventilators and dual-sided anti-fog treated lenses. They can be worn over prescription glasses, ensuring safer operations. (Note: Large glasses may not be compatible.)</p>
<p data-start="48" data-end="515"><img loading="lazy" decoding="async" class="aligncenter wp-image-56398" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-115105.png" alt="" width="323" height="204" /></p>
<p data-start="522" data-end="568"><strong>High-Performance Ventilators</strong></p>
<ul>
<li data-start="572" data-end="645">Lens: Cellulose-based plastic (dual-sided anti-fog treatment)</li>
<li data-start="648" data-end="679">Frame: Soft vinyl</li>
<li data-start="682" data-end="700">Headband: Nylon</li>
</ul>
<h3><strong>Dust Protective Hood</strong><br />
Prevents dust accumulation on the <strong data-start="72" data-end="86">head and shoulders</strong>.</h3>
<p><strong>Sakai – Type A</strong><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56399" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-115238.png" alt="" width="244" height="277" /></p>
<div class="table-container">
<table>
<tbody>
<tr>
<th class="col-label" style="width: 50%;"><strong>Compatible Masks</strong></th>
<td class="col-value">Hi-Luck, 1010A, etc.</td>
</tr>
<tr>
<th class="col-label"><strong>Vision Window</strong></th>
<td class="col-value">Cellulose Plastic</td>
</tr>
<tr>
<th class="col-label"><strong>Fabric</strong></th>
<td class="col-value">Canvas</td>
</tr>
</tbody>
</table>
</div>
<p><strong>Sakai – Type C</strong> <img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56400" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-115246.png" alt="" width="259" height="295" /></p>
<div class="table-container">
<table>
<tbody>
<tr class="feature-row">
<th colspan="2"><strong>Features inhalation port, front button style</strong></th>
</tr>
<tr>
<th class="col-label" style="width: 50%;"><strong>Compatible Masks</strong></th>
<td class="col-value">Hi-Luck, 1010A, 1021R, 1121R, 1005R, etc.</td>
</tr>
<tr>
<th class="col-label"><strong>Vision Window</strong></th>
<td class="col-value">Cellulose Plastic</td>
</tr>
<tr>
<th class="col-label"><strong>Fabric</strong></th>
<td class="col-value">Canvas</td>
</tr>
</tbody>
</table>
</div>
<p data-start="26" data-end="105">※ Masks shown in illustrations are not included with the hood.</p>
<p data-start="107" data-end="164" data-is-last-node="" data-is-only-node=""><strong>Note:</strong> Product is not water-resistant.</p>
<h2>Associated Testing Equipment</h2>
<h3><strong>Filter Replacement Indicator – Type 7M / 7S</strong></h3>
<p data-start="108" data-end="204"><strong>Type 7M (For Medium facepieces):</strong><br />
1005, 1021, 1091, 1121, 1191, 1122, 1181, 7191, 7121, 6061</p>
<p data-start="206" data-end="278"><strong>Type 7S (For Small facepieces):</strong><br />
1005, 1021, 1121, 1122, 1181, 7121</p>
<p data-start="280" data-end="588">This tester is compatible with masks using Mighty Micron or Alpha Ring filters. Dust accumulation status on the filter is displayed via color-coded indicators, allowing clear confirmation and precise determination of the filter replacement schedule.</p>
<p><strong>Options</strong></p>
<ul>
<li data-start="609" data-end="642">For Model 1010</li>
<li data-start="645" data-end="717">For Model 1111 / 1180 (Compatible with 1015)</li>
<li data-start="720" data-end="774">Medium Facepiece Connector</li>
<li data-start="777" data-end="829">Small Facepiece Connector</li>
</ul>
<p data-start="831" data-end="873" data-is-last-node="" data-is-only-node="">※ Not compatible with Model 1180 size S.</p>
<p data-start="831" data-end="873" data-is-last-node="" data-is-only-node=""><img loading="lazy" decoding="async" class="size-medium wp-image-193331 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-12-243x300.jpg" alt="" width="243" height="300" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-12-243x300.jpg 243w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-12-768x949.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-12.jpg 829w" sizes="auto, (max-width: 243px) 100vw, 243px" /></p>
<ul>
<li data-start="82" data-end="127">Power Consumption: 50 W</li>
<li data-start="130" data-end="172">Power Supply: AC 100 V</li>
<li data-start="175" data-end="212">Weight: 6.5 kg</li>
</ul>
<h3><strong>Qualitative Fit Test Kit FIT-Ⅱ</strong></h3>
<p data-start="71" data-end="250">This kit is used for performing qualitative fit testing to assess whether the mask fits the user&#8217;s face securely with an airtight seal. (Complies with JIS T 8150)</p>
<ul>
<li data-start="254" data-end="326">Uses Sodium Saccharin solution (sweet taste component).</li>
<li data-start="329" data-end="410">Includes 10 hoods, convenient for testing multiple personnel.</li>
<li data-start="413" data-end="541">Distinct color-coded labels for easy identification of screening (sensitivity) and fit test solutions.</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56402" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-120048.png" alt="" width="254" height="298" /></p>The post <a href="https://koueitrading.com/global/product/koken-1021-series-and-1091d-04-dust-mask/">Koken 1021 Series And 1091D-04 Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken 1521 Series Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-1521-series-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Tue, 17 Mar 2020 06:31:20 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=193326</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: 1521 Series Important points when wearing a mask Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself from inhaling particles while wearing a dust mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical. [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-1521-series-dust-mask/">Koken 1521 Series Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: 1521 Series</p>
<h2>Important points when wearing a mask</h2>
<p>Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself from inhaling particles while wearing a dust mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Through unique technology, wool fibers are electrostatically charged, allowing electrostatic force to draw particles to the fiber surface. This is the primary mechanism for collecting particles. A high-density fiber structure is unnecessary, successfully integrating the two contrasting features: &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221; It consistently maintains the highest standard of performance and quality, making it an excellent long-term filter solution.</p>
<table>
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applied products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the fiber density of the filter enhances collection efficiency. To meet airflow resistance standards, paper filters traditionally require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into pristine circular shapes in a single process, creating the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" alt="" width="329" height="127" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applied products are from page P.8 to P.11</p>
<p data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<th style="height: 14.4pt; width: 48pt;" width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td style="width: 48pt;" width="64">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the &#8220;Dust Respirator Standards&#8221;.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" style="width: 45%;" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct-Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table" style="font-size: 12px;">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Particles</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ /min</td>
<td class="text-center" colspan="2">85 ℓ /min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Collection Efficiency</strong><br />
<strong>(Measured continuously; must meet right-column values)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" style="font-size: 12px;" colspan="2">NaCl Test Particles<br />
Load up to 100mg</td>
<td class="text-left" style="font-size: 12px;" colspan="2">DOP Test Particles<br />
Load up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or higher</td>
<td>RL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or higher</td>
<td>RL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or higher</td>
<td>RL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or higher</td>
<td>DL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or higher</td>
<td>DL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or higher</td>
<td>DL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" style="text-align: center;" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" style="text-align: center;" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" style="text-align: center;" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" style="text-align: center;" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>Values in ( ) refer to products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col" style="width: 25%;">Airtightness performance test for the exhalation valve</td>
<td>&#8211; Internal pressure must drop immediately when air is drawn.<br />
&#8211; Time for internal pressure to return to normal atmospheric pressure must be 15 seconds or more.</td>
</tr>
<tr>
<th class="header-col"><strong>Carbon Dioxide (CO2) Concentration Increase</strong></th>
<td class="content-col" colspan="2">Measured using a test headform and artificial lung to inhale/exhale CO2-enriched air. The difference in CO2 concentration in inhaled air with and without the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space</strong></th>
<td class="content-col" colspan="2">Value calculated from the (CO2 Concentration Increase Test).</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase Value</strong></th>
<td class="header-sub">Test Particles</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">Measured at 40 ℓ/min after loading test dust at 85 ℓ/min.</td>
</tr>
<tr>
<td class="header-sub">Amount Loaded onto Dust Mask</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Particles &amp; Collection Efficiency </span><span class="bottom-left-text">Disposable Type<br />
/ Replaceable Type</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" style="width: 25%;" rowspan="2"><strong>Classification</strong><br />
<strong>(Collection Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender" style="font-weight: normal; font-size: 12px;"><strong>Solid NaCl Test Particles</strong></th>
<th class="bg-lavender" style="font-weight: normal; font-size: 12px;"><strong>Liquid DOP Test Particles</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Mask</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (Above 80.0%)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (Above 95.0%)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (Above 99.9%)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Mask</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (Above 80.0%)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (Above 95.0%)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (Above 99.9%)</td>
</tr>
</tbody>
</table>
<h2>High Performance Filter + Ergonomic Face Seal</h2>
<h3>2. Facepiece Fit Technology</h3>
<p>Even if a dust mask has a high collection efficiency filter, it is ineffective if dust leaks through the seal between the face and the mask. The primary cause is the &#8220;gap at the facial contact area.&#8221; We consider mask fit to be as important as filter performance. Therefore, our company developed technology to enhance the airtightness of the facepiece seal early on.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" alt="" width="247" height="326" /><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and effortlessly adapts to facial movements, ensuring a comfortable fit. The material is also stable during long-term use.</p>
<p><strong>HAWC harness strap</strong><br />
The strap design ensures high tension and maximizes the “suction” effect when wearing the mask, ensuring an airtight facial seal. <img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" alt="" width="145" height="163" /></p>
<p><strong>Freeposition Underchin</strong><br />
The unique curve of the facial contact area prevents dust entry. By aligning the nose section first, it accommodates various facial dimensions, providing a secure fit for a wide range of face sizes (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" alt="" width="192" height="115" /></p>
<p><strong>Fit Status of the Freeposition Underchin Mask</strong><br data-start="112" data-end="115" />(Cross-sectional simulation to show the contact position between the mask and the chin).</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><strong data-start="56" data-end="94">For large faces:</strong><br data-start="94" data-end="97" />The outer section of the mask adjusts the fit around the chin.</td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td style="width: 48pt;" width="64"><strong data-start="164" data-end="202">For small faces:</strong><br data-start="202" data-end="205" />The inner section of the mask adjusts the fit around the chin.</td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr style="height: 14.4pt;">
<th class="xl65" style="height: 14.4pt; width: 96pt;" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" style="width: 96pt;" colspan="2" width="128"><strong>Wearing Stability</strong></th>
<th class="xl65" style="width: 96pt;" colspan="2" width="128"><strong>Built-in Fit Checker</strong></th>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>The cushion naturally conforms to various face shapes and sizes for a seamless fit.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Uses a 3D-shaped polyband harness that contours to the head, enhancing fit and sealing performance.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>Built-in fit checker allows you to test the mask&#8217;s seal at any time (available for 1005, 1010A, 1015, 1180 series).</td>
</tr>
</tbody>
</table>
<h2 data-start="26" data-end="80"><strong data-start="26" data-end="80">Replaceable Dust Mask – Alpha Ring Filter</strong></h2>
<p data-start="82" data-end="140"><strong data-start="82" data-end="140">Alpha Ring Filter with concentric design and compact shape</strong></p>
<p data-start="142" data-end="665" data-is-last-node="" data-is-only-node="">Paper filters that enhance particle collection efficiency by increasing fiber density traditionally require an expanded surface area to meet airflow resistance standards.<br data-start="295" data-end="298" />The Alpha Ring filter was the first domestically developed filter using ultra-fine fibers molded into a round pleat structure.<br data-start="457" data-end="460" />By continuing to expand the filtration surface area, the filter maintains a compact shape while achieving lower breathing resistance, resulting in higher and more stable performance.</p>
<p data-start="142" data-end="665" data-is-last-node="" data-is-only-node=""><img loading="lazy" decoding="async" class="aligncenter wp-image-56406" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122720.png" alt="" width="298" height="236" /></p>
<p data-start="26" data-end="84"><strong data-start="26" data-end="84">All Alpha Ring filters are water-repellent treated</strong></p>
<p data-start="26" data-end="84"><img loading="lazy" decoding="async" class="aligncenter wp-image-56407" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122749.png" alt="" width="168" height="140" /></p>
<p data-start="86" data-end="307">The filter is treated for water repellency to limit the adherence of mist or droplets, ensuring breathing remains easy during use.<br data-start="224" data-end="227" />Additionally, this treatment is effective against oil mist.</p>
<p data-start="314" data-end="338"><strong data-start="314" data-end="338">HAWC Lip (High Adaptable Wide Concave)</strong></p>
<p data-start="314" data-end="338"><img loading="lazy" decoding="async" class="aligncenter wp-image-56408" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122803.png" alt="" width="149" height="184" /></p>
<p data-start="340" data-end="498">The facial contact area has a wide concave surface that surrounds the face. When the harness is tightened, a suction effect is created, resulting in high airtightness.</p>
<p data-start="500" data-end="602" data-is-last-node="" data-is-only-node="">*HAWC stands for High Adaptable Wide Concave<br data-start="554" data-end="557" />*Image shown is the Model 1021H.</p>
<p data-start="500" data-end="602" data-is-last-node="" data-is-only-node=""><strong>(Head Harness Types)</strong><br data-start="46" data-end="49" />Please replace head straps periodically.</p>
<p data-start="500" data-end="602" data-is-last-node="" data-is-only-node=""><img loading="lazy" decoding="async" class=" wp-image-192866 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11-300x94.jpg" sizes="auto, (max-width: 543px) 100vw, 543px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11-300x94.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11-768x241.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11.jpg 1024w" alt="" width="543" height="170" /></p>
<h2 data-start="26" data-end="63"><strong data-start="65" data-end="86">Sakai Model 1521H</strong></h2>
<p data-start="26" data-end="63">Durable silicone facepiece, easy to clean</p>
<p data-start="65" data-end="158">Model Assay Certificate: TM534<br data-start="120" data-end="123" />Assigned Protection Factor: 50 (RL3)</p>
<p data-start="160" data-end="312">Also applicable for use as a gas mask (1521HG · Class L3)<br data-start="238" data-end="241" />(Model Assay Certificate: TN399)<br data-start="274" data-end="277" />Note: Absorbent canisters are sold separately.</p>
<p data-start="160" data-end="312"><img loading="lazy" decoding="async" class="aligncenter wp-image-56409" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-123057.png" alt="" width="261" height="236" /></p>
<ul>
<li data-start="339" data-end="400">Silicone Construction</li>
<li data-start="403" data-end="416">HAWC Lip</li>
<li data-start="419" data-end="474">Speaking Diaphragm</li>
<li data-start="477" data-end="504">Spatter-shielding Surface</li>
</ul>
<div class="table-container">
<table>
<tbody>
<tr>
<th class="col-label"><strong>Particle Collection Efficiency</strong></th>
<td class="col-value">
<div class="value-wrapper">99.9% or higher<br />
(Average 99.99%)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">115Pa or less<br />
(Average 90Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">45Pa or less<br />
(Average 33Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Resistance Increase</strong></th>
<td class="col-value">
<div class="value-wrapper">―<br />
(Average 108Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-value">
<div class="value-wrapper">625g or less<br />
(Average 595g)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Head Harness</strong></th>
<td class="col-value">Type H-VII Rubber Harness</td>
</tr>
</tbody>
</table>
</div>
<p data-start="26" data-end="57"><strong data-start="26" data-end="55">Replacement Parts</strong></p>
<ul>
<li data-start="60" data-end="90">Inhalation Valve: Type 29</li>
<li data-start="93" data-end="132">Partitioned Inhalation Valve: Type NC2</li>
<li data-start="135" data-end="160">Exhalation Valve: Type T-6K</li>
</ul>
<h2 data-start="112" data-end="170"><strong data-start="172" data-end="193">Sakai Model 1521U</strong></h2>
<p data-start="112" data-end="170">High-safety full-face mask, suitable for nanomaterials</p>
<p data-start="172" data-end="265">Model Assay Certificate: TM675<br data-start="227" data-end="230" />Assigned Protection Factor: 50 (RL3)</p>
<p data-start="267" data-end="520">The particle collection efficiency reaches 99.999% (average value), meeting high safety requirements for handling nanomaterials.<br data-start="409" data-end="412" />The full-face design combined with the HAWC Lip creates an exceptional airtight seal, significantly enhancing protection levels.</p>
<p data-start="267" data-end="520"><img loading="lazy" decoding="async" class="aligncenter wp-image-56410" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-125525.png" alt="" width="261" height="231" /></p>
<ul>
<li data-start="550" data-end="661">HAWC Lip</li>
<li data-start="664" data-end="748">Speaking Diaphragm</li>
<li data-start="751" data-end="822">Anti-fouling Surface</li>
<li data-start="825" data-end="904">Silicone Facepiece</li>
</ul>
<div class="table-container">
<table>
<tbody>
<tr>
<th class="col-label"><strong>Particle Collection Efficiency</strong></th>
<td class="col-value">
<div class="value-wrapper">99.99% or higher<br />
(Average 99.999%)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">137Pa or less<br />
(Average 98Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">60Pa or less<br />
(Average 33Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Resistance Increase</strong></th>
<td class="col-value">
<div class="value-wrapper">―<br />
(Average 112Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-value">
<div class="value-wrapper">625g or less<br />
(Average 589g)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Head Harness</strong></th>
<td class="col-value">Type H-VII Rubber Harness</td>
</tr>
</tbody>
</table>
<h3 data-start="26" data-end="61">Notes on Filter Replacement</h3>
<p data-start="88" data-end="354">As dust accumulates in the filter, breathing resistance increases, making respiration more difficult.<br data-start="201" data-end="204" />Furthermore, besides difficult breathing, if the mask does not fit perfectly against the face, dust can bypass the filter through any gaps.</p>
<ul>
<li data-start="358" data-end="489">Always perform a seal check before use and ensure the mask is firmly secured to your face.</li>
<li data-start="492" data-end="589">Replace the filter before breathing becomes difficult to prevent excessive resistance buildup.</li>
</ul>
<p data-start="591" data-end="705" data-is-last-node="" data-is-only-node="">*If you have any questions regarding replacement, please contact our office or local agent.</p>
</div>
<p><strong>Replacement Filters · Optional Accessories</strong></p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><strong data-start="43" data-end="51">RD-6</strong> (For: 1721H, 1521H, 7121R, 7191DK)</td>
<td style="width: 48pt;" width="64"><strong data-start="125" data-end="134">RD-6U</strong> (For: 7191DKU, 1521U)</td>
<td style="width: 48pt;" width="64"><strong data-start="195" data-end="203">RD-8</strong> (For: 1180H)</td>
<td style="width: 48pt;" width="64"><strong data-start="240" data-end="250">LAS-52</strong> (For: 1781DW)</td>
<td style="width: 48pt;" width="64"><strong data-start="303" data-end="314">LAS-52C</strong> (For: 1781DWC)</td>
<td style="width: 48pt;" width="64"><strong data-start="28" data-end="72">(Optional) Fit Tester – Type V</strong><br data-start="72" data-end="75" />Applied models: 1721H, 1521H, 1521U, 7121R, 7191DK, 7191DKU</td>
<td style="width: 48pt;" width="64"><strong data-start="149" data-end="193">(Optional) Fit Tester – Type F</strong><br data-start="193" data-end="196" />Applied models: 1781DW, 1781DWC</td>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56411" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-125924.png" alt="" width="154" height="110" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56412" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-125934.png" alt="" width="154" height="108" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56413" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-125953.png" alt="" width="145" height="115" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56414" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-130005.png" alt="" width="142" height="109" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56415" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-130016.png" alt="" width="153" height="112" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56416" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-131200.png" alt="" width="199" height="122" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56417" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-131207.png" alt="" width="209" height="116" /></td>
</tr>
<tr>
<td height="19">2 pcs/set — Threaded</td>
<td>2 pcs/set — Threaded</td>
<td>Threaded</td>
<td>2 pcs/set — Threaded</td>
<td>2 pcs/set — Threaded</td>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<ul>
<li data-start="28" data-end="137">Fit Checker: Simply operate the lever to perform a user seal check (fit test).</li>
<li data-start="140" data-end="226">Under-Chin: Unique curve enhances the airtight seal between face and mask.</li>
<li data-start="229" data-end="347">Silicone: Soft, skin-friendly material; silicone facepiece ensures comfortable long-term wear.</li>
<li data-start="350" data-end="436">HAWC Lip: Achieves high airtightness via &#8220;suction effect&#8221;; applied to full-face models.</li>
<li data-start="439" data-end="498">Size S available: Size S options for users with petite faces.</li>
<li data-start="501" data-end="620">Low breathing resistance: Employs Alpha Ring filter technology for reduced breathing effort during long shifts.</li>
<li>Speaking Diaphragm: Integrated device enables clear verbal communication while wearing the mask.</li>
<li>Activated Carbon: Effectively neutralizes low-concentration ozone; utilizes carbon-impregnated filters.</li>
<li>Surface Hardening: Visor lens is treated to resist scratches.</li>
<li>Special Surface Hardening: Advanced coating provides superior scratch protection over standard treatments.</li>
</ul>
<p><strong data-start="452" data-end="462">Note:</strong> Consumable components and filters should be replaced promptly according to the maintenance schedule.</p>The post <a href="https://koueitrading.com/global/product/koken-1521-series-dust-mask/">Koken 1521 Series Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken 1721H-03 Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-1721h-03-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Tue, 17 Mar 2020 06:27:17 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=193324</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: 1721H-03 Important Points When Wearing a Respirator Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself from inhaling dust while wearing a respirator, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and the face are critical. 1. Filter [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-1721h-03-dust-mask/">Koken 1721H-03 Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: 1721H-03</p>
<h2>Important Points When Wearing a Respirator</h2>
<p>Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself from inhaling dust while wearing a respirator, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and the face are critical.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Using unique technology, wool fibers are electrostatically charged, allowing electrostatic force to draw particles to the fiber surface. This is the primary mechanism for capturing particles. A high-density fiber structure is unnecessary, successfully integrating the two contrasting features: &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221; It consistently maintains the highest standard of performance and quality, making it an excellent long-term filter solution.</p>
<table>
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applied products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the fiber density of the filter enhances collection efficiency. To meet airflow resistance standards, paper filters traditionally require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into pristine circular shapes in a single process, creating the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" alt="" width="329" height="127" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applied products are from page P.8 to P.11</p>
<p data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<th style="height: 14.4pt; width: 48pt;" width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td style="width: 48pt;" width="64">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the &#8220;Dust Respirator Standards&#8221;.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" style="width: 45%;" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct-Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table" style="font-size: 12px;">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Particles</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ /min</td>
<td class="text-center" colspan="2">85 ℓ /min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement; must meet values in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" style="font-size: 12px;" colspan="2">For NaCl test aerosol<br />
Loaded up to 100mg</td>
<td class="text-left" style="font-size: 12px;" colspan="2">For DOP test aerosol<br />
Loaded up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or higher</td>
<td>RL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or higher</td>
<td>RL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or higher</td>
<td>RL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or higher</td>
<td>DL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or higher</td>
<td>DL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or higher</td>
<td>DL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" style="text-align: center;" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" style="text-align: center;" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" style="text-align: center;" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" style="text-align: center;" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td style="text-align: center;" colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>( ) indicates products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col" style="width: 25%;">Exhalation valve operation leak test</td>
<td>&#8211; When air is drawn, the internal pressure must decrease immediately<br />
&#8211; The time for internal pressure to return to normal atmospheric pressure must be 15 seconds or more</td>
</tr>
<tr>
<th class="header-col"><strong>Carbon Dioxide (CO2) Concentration Increase</strong></th>
<td class="content-col" colspan="2">Using a test headform and an artificial lung to inhale/exhale air containing CO2. The difference in CO2 concentration in the inhaled air between wearing and not wearing the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space Volume</strong></th>
<td class="content-col" colspan="2">Calculated from the (Carbon Dioxide Concentration Increase Test)</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Particles</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">Measured at 40 ℓ/min after loading test dust at 85 ℓ/min</td>
</tr>
<tr>
<td class="header-sub">Amount loaded onto dust respirator</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Aerosol and Efficiency </span><span class="bottom-left-text">Disposable Type<br />
/ Replaceable Type</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" style="width: 25%;" rowspan="2"><strong>Classification</strong><br />
<strong>(Particle Collection Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender" style="font-weight: normal; font-size: 12px;"><strong>Test aerosol is solid NaCl</strong></th>
<th class="bg-lavender" style="font-weight: normal; font-size: 12px;"><strong>Test aerosol is liquid DOP</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (80.0% or higher)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (95.0% or higher)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (99.9% or higher)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (80.0% or higher)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (95.0% or higher)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (99.9% or higher)</td>
</tr>
</tbody>
</table>
<h2>High Efficiency Filter + Ergonomic Face Seal</h2>
<h3>2. Facepiece Fit Technology</h3>
<p>Even if a dust mask has a high collection efficiency filter, it is meaningless if particles leak through the seal during use. The primary cause of exposure is the &#8220;gap at the facial contact area.&#8221; We consider mask fit to be as important as filter performance. Therefore, our company developed technology to enhance the airtightness of the facepiece seal early on.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" alt="" width="247" height="326" /><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and effortlessly adapts to facial movements, ensuring wearing comfort and stability during use.</p>
<p><strong>HAWC harness strap</strong><br />
The strap design ensures a high level of fit, maximizing the &#8220;suction&#8221; effect when wearing the mask to ensure an airtight seal on the face. <img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" alt="" width="145" height="163" /></p>
<p><strong>Freeposition Under-Chin</strong><br />
The special shape of the facial contact area prevents dust entry. The nose section is aligned first, allowing it to accommodate various facial dimensions and providing a secure fit for a wide range of face sizes (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" alt="" width="192" height="115" /></p>
<p><strong>Fit Status of the Freeposition Under-Chin Facepiece</strong><br data-start="112" data-end="115" />(Cross-sectional simulation to show the contact position between the mask and the chin).</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><strong data-start="56" data-end="94">For large faces:</strong><br data-start="94" data-end="97" />Uses the outer section of the mask to adjust the fit around the chin.</td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td style="width: 48pt;" width="64"><strong data-start="164" data-end="202">For small faces:</strong><br data-start="202" data-end="205" />Uses the inner section of the mask to adjust the fit around the chin.</td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr style="height: 14.4pt;">
<th class="xl65" style="height: 14.4pt; width: 96pt;" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" style="width: 96pt;" colspan="2" width="128"><strong>Wearing Stability</strong></th>
<th class="xl65" style="width: 96pt;" colspan="2" width="128"><strong>Internal Fit Checker</strong></th>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed for various face shapes; the cushion naturally fits your face.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Utilizes a 3D poly-band harness that matches head shapes to enhance the feeling of fit and seal.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>Fit checker is integrated inside, helping to check the mask seal at any time (available for models 1005, 1010A, 1015, 1180 series).</td>
</tr>
</tbody>
</table>
<h2 data-start="26" data-end="80"><strong data-start="26" data-end="80">Replaceable Dust Respirator – Alpha Ring Filter</strong></h2>
<p data-start="82" data-end="140"><strong data-start="82" data-end="140">Alpha Ring Filter with concentric design and compact shape</strong></p>
<p data-start="142" data-end="665" data-is-last-node="" data-is-only-node="">Paper filters that enhance particle collection efficiency by increasing fiber density often require an expanded surface area to meet airflow resistance standards.<br data-start="295" data-end="298" />The Alpha Ring filter was the first domestically developed filter using ultra-fine fibers molded into a round pleat structure.<br data-start="457" data-end="460" />Currently, by continuing to expand the filtration surface area, the filter maintains a compact shape while achieving lower breathing resistance, resulting in higher and more stable performance.</p>
<p data-start="142" data-end="665" data-is-last-node="" data-is-only-node=""><img loading="lazy" decoding="async" class="aligncenter wp-image-56406" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122720.png" sizes="auto, (max-width: 298px) 100vw, 298px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122720.png 391w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122720-300x238.png 300w" alt="" width="298" height="236" /></p>
<p data-start="26" data-end="84"><strong data-start="26" data-end="84">All Alpha Ring filters are water-repellent treated</strong></p>
<p data-start="26" data-end="84"><img loading="lazy" decoding="async" class="aligncenter wp-image-56407" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122749.png" alt="" width="168" height="140" /></p>
<p data-start="86" data-end="307">The filter is treated for water repellency to limit the adherence of mist or droplets, ensuring breathing remains easy during use.<br data-start="224" data-end="227" />Additionally, this treatment is effective against oil mist.</p>
<p data-start="314" data-end="338"><strong data-start="314" data-end="338">HAWC Lip (High Adaptable Wide Concave)</strong></p>
<p data-start="314" data-end="338"><img loading="lazy" decoding="async" class="aligncenter wp-image-56408" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122803.png" alt="" width="149" height="184" /></p>
<p data-start="340" data-end="498">The facial contact area has a wide concave surface that surrounds the face. When the harness is tightened, a suction effect is created, resulting in high airtightness.</p>
<p data-start="500" data-end="602" data-is-last-node="" data-is-only-node="">*HAWC stands for High Adaptable Wide Concave<br data-start="554" data-end="557" />*Image shown is the Model 1021H.</p>
<p data-start="500" data-end="602" data-is-last-node="" data-is-only-node=""><strong>(Head Harness Types)</strong><br data-start="46" data-end="49" />Please replace head straps periodically.</p>
<p data-start="500" data-end="602" data-is-last-node="" data-is-only-node=""><img loading="lazy" decoding="async" class=" wp-image-192866 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11-300x94.jpg" sizes="auto, (max-width: 543px) 100vw, 543px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11-300x94.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11-768x241.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11.jpg 1024w" alt="" width="543" height="170" /></p>
<h2 data-start="26" data-end="65"><strong data-start="77" data-end="104">Sakaki – Model 1721H-03</strong></h2>
<p data-start="26" data-end="65">High-durability protective goggles and facepiece</p>
<p data-start="67" data-end="170">RL3 Rating<br data-start="74" data-end="77" />Type Certification: TM646<br data-start="138" data-end="141" />Assigned Protection Factor: 50</p>
<p data-start="172" data-end="323">Additionally, it can be used as a gas mask<br data-start="226" data-end="229" />(Model 1721HG · Class L3)<br data-start="256" data-end="259" />(Absorbent canisters sold separately)<br data-start="288" data-end="291" data-is-only-node="" />(Type Certification: TN75)</p>
<p data-start="172" data-end="323"><img loading="lazy" decoding="async" class="aligncenter wp-image-56422" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-133104.png" alt="" width="266" height="308" /></p>
<ul>
<li data-start="352" data-end="363">HAWC Lip</li>
<li data-start="366" data-end="422">Speaking Diaphragm (facilitates communication and commands)</li>
<li data-start="425" data-end="461">Hardened visor surface treatment</li>
</ul>
<div class="table-title">
<table class="spec-table">
<tbody>
<tr>
<th class="col-label"><strong>Particle Collection Efficiency</strong></th>
<td class="col-value">
<div class="value-wrapper">99.9% or higher<br />
(Average 99.99%)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">115Pa or less<br />
(Average 91Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">60Pa or less<br />
(Average 34Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Resistance Increase</strong></th>
<td class="col-value">
<div class="value-wrapper">―<br />
(Average 106Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-value">
<div class="value-wrapper">554g or less<br />
(Average 536g)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Head Harness</strong></th>
<td class="col-value">HV Type Rubber Harness</td>
</tr>
</tbody>
</table>
</div>
<p data-start="26" data-end="58"><strong data-start="26" data-end="58">Shared Replacement Parts</strong></p>
<ul>
<li data-start="62" data-end="90">Inhalation Valve: circular type</li>
<li data-start="93" data-end="136">Partitioned Inhalation Valve: NC type</li>
<li data-start="139" data-end="176">Exhalation Valve: T-6K type (white)</li>
</ul>
<div class="table-container">
<h3 data-start="26" data-end="61">Notes on Filter Replacement</h3>
<p data-start="88" data-end="354">As dust accumulates in the filter, breathing resistance increases, making respiration more difficult.<br data-start="201" data-end="204" />Furthermore, beyond difficult breathing, if the mask does not fit perfectly against the face, dust can bypass the filter through any gaps.</p>
<ul>
<li data-start="358" data-end="489">Always perform a seal check before use and ensure the mask is firmly secured to your face.</li>
<li data-start="492" data-end="589">Replace the filter before breathing becomes difficult to prevent excessive resistance buildup.</li>
</ul>
<p data-start="591" data-end="705" data-is-last-node="" data-is-only-node="">*If you have any questions regarding replacement, please contact our office or local agent.</p>
</div>
<p><strong>Replacement Filters · Optional Accessories</strong></p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong data-start="43" data-end="51">RD-6</strong> (For: 1721H, 1521H, 7121R, 7191DK)</td>
<td width="64"><strong data-start="125" data-end="134">RD-6U</strong> (For: 7191DKU, 1521U)</td>
<td width="64"><strong data-start="195" data-end="203">RD-8</strong> (For: 1180H)</td>
<td width="64"><strong data-start="240" data-end="250">LAS-52</strong> (For: 1781DW)</td>
<td width="64"><strong data-start="303" data-end="314">LAS-52C</strong> (For: 1781DWC)</td>
<td width="64"><strong data-start="28" data-end="72">(Optional) Fit Tester – Type V</strong><br data-start="72" data-end="75" />Applied models: 1721H, 1521H, 1521U, 7121R, 7191DK, 7191DKU</td>
<td width="64"><strong data-start="149" data-end="193">(Optional) Fit Tester – Type F</strong><br data-start="193" data-end="196" />Applied models: 1781DW, 1781DWC</td>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56411" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-125924.png" alt="" width="154" height="110" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56412" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-125934.png" alt="" width="154" height="108" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56413" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-125953.png" alt="" width="145" height="115" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56414" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-130005.png" alt="" width="142" height="109" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56415" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-130016.png" alt="" width="153" height="112" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56416" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-131200.png" alt="" width="199" height="122" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56417" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-131207.png" alt="" width="209" height="116" /></td>
</tr>
<tr>
<td height="19">2 pcs/set — Threaded</td>
<td>2 pcs/set — Threaded</td>
<td>Threaded</td>
<td>2 pcs/set — Threaded</td>
<td>2 pcs/set — Threaded</td>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<ul>
<li data-start="28" data-end="137">Fit Checker: Simply operate the lever to perform a user seal check (fit test).</li>
<li data-start="140" data-end="226">Under-Chin: Unique curve enhances the airtight seal between face and mask.</li>
<li data-start="229" data-end="347">Silicone: Soft, skin-friendly material; silicone facepiece ensures comfortable long-term wear.</li>
<li data-start="350" data-end="436">HAWC Lip: High airtightness achieved through a &#8220;suction effect&#8221;; applied to full-face models.</li>
<li data-start="439" data-end="498">Size S available: Size S options for users with petite faces.</li>
<li data-start="501" data-end="620">Low breathing resistance: Employs Alpha Ring filter technology for reduced breathing effort during long shifts.</li>
<li>Speaking Diaphragm: Integrated device enables clear verbal communication while wearing the mask.</li>
<li>Activated Carbon: Effectively neutralizes low-concentration ozone; utilizes carbon-impregnated filters.</li>
<li>Surface Hardening: Visor lens is treated to resist scratches.</li>
<li>Special Surface Hardening: Advanced coating provides superior scratch protection over standard treatments.</li>
</ul>
<p><strong data-start="452" data-end="462">Note:</strong> Consumable components and filters should be replaced early and on schedule.</p>The post <a href="https://koueitrading.com/global/product/koken-1721h-03-dust-mask/">Koken 1721H-03 Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken 1781 Series Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-1781-series-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Tue, 17 Mar 2020 06:21:00 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=193322</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: 1781 Series Important points when wearing a mask Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself from inhaling dust while wearing a dust mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical. [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-1781-series-dust-mask/">Koken 1781 Series Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: 1781 Series</p>
<h2>Important points when wearing a mask</h2>
<p>Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself from inhaling dust while wearing a dust mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Using unique technology, wool fibers are electrostatically charged, allowing electrostatic force to draw particles to the fiber surface. This is the primary mechanism for capturing particles. A high-density fiber structure is unnecessary, successfully integrating the two contrasting features: &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221; It consistently maintains the highest standard of performance and quality, making it an excellent long-term filter solution.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" sizes="auto, (max-width: 317px) 100vw, 317px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png 317w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333-300x204.png 300w" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" sizes="auto, (max-width: 316px) 100vw, 316px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png 316w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322-300x227.png 300w" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applied products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the fiber density of the filter enhances collection efficiency. To meet airflow resistance standards, paper filters traditionally require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into pristine circular shapes in a single process, creating the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" sizes="auto, (max-width: 329px) 100vw, 329px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751-300x116.png 300w" alt="" width="329" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" sizes="auto, (max-width: 321px) 100vw, 321px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png 321w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803-300x227.png 300w" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applied products are from page P.8 to P.11</p>
<p data-start="46" data-end="81"><strong>Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong>Dust Respirator Standards</strong></th>
<td width="64">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the “Dust Respirator Standards”.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct-Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Particles</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride) particles</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate) particles</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ /min</td>
<td class="text-center" colspan="2">85 ℓ /min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement; must meet values in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" colspan="2">For NaCl particles<br />
Load up to 100mg</td>
<td class="text-left" colspan="2">For DOP particles<br />
Load up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or higher</td>
<td>RL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or higher</td>
<td>RL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or higher</td>
<td>RL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or higher</td>
<td>DL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or higher</td>
<td>DL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or higher</td>
<td>DL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>( ) is for products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col">Exhalation valve leak test</td>
<td>– Internal pressure must drop immediately during suction.<br />
– Time for internal pressure to return to normal must be 15 seconds or more.</td>
</tr>
<tr>
<th class="header-col"><strong>CO2 Concentration Increase</strong></th>
<td class="content-col" colspan="2">Measured using a test headform and artificial lung. The difference in CO2 concentration in inhaled air with and without the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space</strong></th>
<td class="content-col" colspan="2">Value calculated from the CO2 Concentration Increase Test.</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Particles</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">After dust accumulation at 85 ℓ/min, measurement is taken at 40 ℓ/min.</td>
</tr>
<tr>
<td class="header-sub">Dust Accumulation Amount</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Aerosol and Collection Efficiency </span><span class="bottom-left-text">Disposable Type<br />
/ Replaceable Type</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" rowspan="2"><strong>Classification</strong><br />
<strong>(Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender"><strong>Test aerosol is solid NaCl</strong></th>
<th class="bg-lavender"><strong>Test aerosol is liquid DOP</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (Above 80.0%)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (Above 95.0%)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (Above 99.9%)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (Above 80.0%)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (Above 95.0%)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (Above 99.9%)</td>
</tr>
</tbody>
</table>
<h2>High Efficiency Filter + Face-Friendly Surface</h2>
<h3>2. Surface Engineering for a Better Facial Fit</h3>
<p>Even if a dust respirator has a high collection efficiency filter, it is meaningless if dust leaks through the face-to-mask seal during use. This is primarily caused by a &#8220;gap at the face contact area when worn.&#8221; We consider mask fit to be as important as filter performance. Therefore, our company has developed technology to enhance the airtightness of the facial contact area.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" sizes="auto, (max-width: 247px) 100vw, 247px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg 775w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-227x300.jpg 227w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-768x1015.jpg 768w" alt="" width="247" height="326" /></p>
<p><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and effortlessly adapts to facial movements, ensuring a comfortable fit. The material also remains stable during use.</p>
<p><strong>HAWC harness strap</strong><br />
The strap design ensures a high level of fit, maximizing the &#8220;suction&#8221; effect when wearing the mask to ensure an airtight seal on the face.<img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" sizes="auto, (max-width: 145px) 100vw, 145px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png 319w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014-267x300.png 267w" alt="" width="145" height="163" /></p>
<p><strong>Freeposition Underchin</strong><br />
The unique curve of the face contact area prevents dust from leaking in. By aligning the nose portion first, it accommodates various facial dimensions, providing a secure fit for a wide range of face sizes (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" sizes="auto, (max-width: 192px) 100vw, 192px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png 410w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024-300x180.png 300w" alt="" width="192" height="115" /></p>
<p><strong data-start="56" data-end="112">Fit Status of the Freeposition Underchin Facepiece</strong><br data-start="112" data-end="115" />(Simulated image with the mask cut away to clearly show where it contacts the chin).</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong data-start="56" data-end="94">For large faces:</strong><br data-start="94" data-end="97" />Uses the outer section of the mask to adjust the fit around the chin.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td width="64"><strong data-start="164" data-end="202">For small faces:</strong><br data-start="202" data-end="205" />Uses the inner section of the mask to adjust the fit around the chin.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Wearing Safety</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Internal Fit Checker</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed for various face shapes; the cushion naturally fits your face.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Utilizes a 3D poly-band harness that matches head shapes to enhance the feeling of fit and seal.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>Fit checker is integrated inside, helping to check the mask seal at any time (for 1005, 1010A, 1015, 1180 series).</td>
</tr>
</tbody>
</table>
<h2 data-start="26" data-end="80"><strong data-start="26" data-end="80">Replaceable Dust Respirator – Alpha Ring Filter</strong></h2>
<p data-start="82" data-end="140"><strong data-start="82" data-end="140">Alpha Ring Filter with concentric design and compact shape</strong></p>
<p data-start="142" data-end="665" data-is-last-node="" data-is-only-node="">Paper filters that enhance particle collection efficiency by increasing fiber density often require an expanded surface area to meet airflow resistance standards.<br data-start="295" data-end="298" />The Alpha Ring filter was the first domestically developed filter using ultra-fine fibers molded into a round pleat structure.<br data-start="457" data-end="460" />Currently, by continuing to expand the filtration surface area, the filter maintains a compact shape while achieving lower breathing resistance, resulting in higher and more stable performance.</p>
<p data-start="142" data-end="665" data-is-last-node="" data-is-only-node=""><img loading="lazy" decoding="async" class="aligncenter wp-image-56406" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122720.png" sizes="auto, (max-width: 298px) 100vw, 298px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122720.png 391w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122720-300x238.png 300w" alt="" width="298" height="236" /></p>
<p data-start="26" data-end="84"><strong data-start="26" data-end="84">All Alpha Ring filters are water-repellent treated</strong></p>
<p data-start="26" data-end="84"><img loading="lazy" decoding="async" class="aligncenter wp-image-56407" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122749.png" alt="" width="168" height="140" /></p>
<p data-start="86" data-end="307">The filter is treated for water repellency to limit the adherence of mist or droplets, ensuring breathing remains easy during use.<br data-start="224" data-end="227" />Additionally, this treatment is effective against oil mist.</p>
<p data-start="314" data-end="338"><strong data-start="314" data-end="338">HAWC Lip (High Adaptable Wide Concave)</strong></p>
<p data-start="314" data-end="338"><img loading="lazy" decoding="async" class="aligncenter wp-image-56408" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122803.png" alt="" width="149" height="184" /></p>
<p data-start="340" data-end="498">The facial contact area has a wide concave surface that surrounds the face. When the harness is tightened, a suction effect is created, resulting in high airtightness.</p>
<p data-start="500" data-end="602" data-is-last-node="" data-is-only-node="">*HAWC stands for High Adaptable Wide Concave<br data-start="554" data-end="557" />*Image shown is the Model 1021H.</p>
<p data-start="500" data-end="602" data-is-last-node="" data-is-only-node=""><strong>(Head Harness Types)</strong><br data-start="46" data-end="49" />Please replace head straps periodically.</p>
<p data-start="500" data-end="602" data-is-last-node="" data-is-only-node=""><img loading="lazy" decoding="async" class=" wp-image-192866 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11-300x94.jpg" sizes="auto, (max-width: 543px) 100vw, 543px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11-300x94.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11-768x241.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11.jpg 1024w" alt="" width="543" height="170" /></p>
<h2 data-start="26" data-end="121"><strong data-start="123" data-end="148">Sakai Model 1781DW-02</strong></h2>
<p data-start="26" data-end="121">Protective goggles and mask materials with high durability.<br data-start="74" data-end="77" />Utilizes HAWC lip for high airtightness seal.</p>
<p data-start="153" data-end="186">Type Certification: TM405<br />
Assigned Protection Factor: 14 (RL2)</p>
<p data-start="153" data-end="186"><img loading="lazy" decoding="async" class="aligncenter wp-image-56425" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-134257.png" alt="" width="238" height="242" /></p>
<ul>
<li data-start="257" data-end="270">HAWC Lip</li>
<li data-start="273" data-end="325">Low inhalation resistance</li>
<li data-start="328" data-end="383">Speaking Diaphragm (facilitates communication/instructions)</li>
<li data-start="386" data-end="424">Lens surface hardening</li>
</ul>
<div class="spec-table-container">
<table class="spec-table">
<tbody>
<tr>
<th class="col-label"><strong>Particle Collection Efficiency</strong></th>
<td class="col-value">
<div class="value-wrapper">95.0% or higher<br />
(Average 98.8%)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">80Pa or less<br />
(Average 56Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">60Pa or less<br />
(Average 32Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Resistance Increase</strong></th>
<td class="col-value">
<div class="value-wrapper">―<br />
(Average 70Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-value">
<div class="value-wrapper">565g or less<br />
(Average 537g)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Head Harness</strong></th>
<td class="col-value">HV Type Harness</td>
</tr>
</tbody>
</table>
</div>
<p data-start="426" data-end="448">Replacement Parts:</p>
<ul>
<li data-start="451" data-end="479">Inhalation Valve: circular type</li>
<li data-start="482" data-end="525">Inhalation Valve with partition: NC type</li>
<li data-start="528" data-end="565">Exhalation Valve: T-6K type (white)</li>
</ul>
<p>When using RL3 high-efficiency filter series or 1781DWC for tasks like welding or grinding, if there is a possibility of sparks, spatter, or hot slag, it is mandatory to install the dedicated inhalation port cover (sold separately) before use.</p>
<h2 data-start="26" data-end="132"><strong data-start="134" data-end="162">Sakai Model 1781DWC-02</strong></h2>
<p data-start="26" data-end="132">Utilizes deodorizing filter – long-term use type.<br data-start="72" data-end="75" /><strong>Danger:</strong> This is not a gas mask.</p>
<p data-start="167" data-end="200">Type Certification: TM426<br />
Assigned Protection Factor: 14 (RL2)</p>
<p data-start="167" data-end="200"><img loading="lazy" decoding="async" class="aligncenter wp-image-56426" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-134934.png" alt="" width="239" height="260" /></p>
<ul>
<li data-start="269" data-end="282">HAWC Lip</li>
<li data-start="285" data-end="310">Low inhalation resistance</li>
<li data-start="313" data-end="331">Speaking Diaphragm</li>
<li data-start="334" data-end="354">Activated Carbon</li>
<li data-start="357" data-end="376">Hardened surface</li>
</ul>
<div class="table-container">
<table>
<tbody>
<tr>
<th class="col-label"><strong>Particle Collection Efficiency</strong></th>
<td class="col-value">
<div class="value-wrapper">95.0% or higher<br />
(Average 99.0%)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">80Pa or less<br />
(Average 52Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">60Pa or less<br />
(Average 34Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Resistance Increase</strong></th>
<td class="col-value">
<div class="value-wrapper">―<br />
(Average 63Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-value">
<div class="value-wrapper">565g or less<br />
(Average 535g)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Head Harness</strong></th>
<td class="col-value">HV Type Harness</td>
</tr>
</tbody>
</table>
</div>
<p data-start="378" data-end="402">Replacement Parts:</p>
<ul>
<li data-start="405" data-end="430">Inhalation Valve (circular)</li>
<li data-start="433" data-end="459">Isolation Inhalation Valve (NC)</li>
<li data-start="462" data-end="497">Exhalation Valve T-6K (white)</li>
</ul>
<div class="table-container">
<h3 data-start="26" data-end="61">Notes on Filter Replacement</h3>
<p data-start="88" data-end="354">As dust accumulates in the filter, breathing resistance increases, making respiration more difficult.<br data-start="201" data-end="204" />Furthermore, beyond difficult breathing, if the mask does not fit perfectly against the face, dust can bypass the filter through any gaps.</p>
<ul>
<li data-start="358" data-end="489">Always perform a seal check before use and ensure the mask is firmly secured to your face.</li>
<li data-start="492" data-end="589">Replace the filter before breathing becomes difficult to prevent excessive resistance buildup.</li>
</ul>
<p data-start="591" data-end="705" data-is-last-node="" data-is-only-node="">*If you have any questions regarding replacement, please contact our office or local agent.</p>
</div>
<p><strong>Replacement Filters · Optional Accessories</strong></p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong data-start="43" data-end="51">RD-6</strong> (for: 1721H, 1521H, 7121R, 7191DK)</td>
<td width="64"><strong data-start="125" data-end="134">RD-6U</strong> (for: 7191DKU, 1521U)</td>
<td width="64"><strong data-start="195" data-end="203">RD-8</strong> (for: 1180H)</td>
<td width="64"><strong data-start="240" data-end="250">LAS-52</strong> (for: 1781DW)</td>
<td width="64"><strong data-start="303" data-end="314">LAS-52C</strong> (for: 1781DWC)</td>
<td width="64"><strong data-start="28" data-end="72">(Optional) Fit Test Device – Type V</strong><br data-start="72" data-end="75" />Applied to models: 1721H, 1521H, 1521U, 7121R, 7191DK, 7191DKU</td>
<td width="64"><strong data-start="149" data-end="193">(Optional) Fit Test Device – Type F</strong><br data-start="193" data-end="196" />Applied to models: 1781DW, 1781DWC</td>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56411" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-125924.png" alt="" width="154" height="110" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56412" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-125934.png" alt="" width="154" height="108" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56413" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-125953.png" alt="" width="145" height="115" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56414" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-130005.png" alt="" width="142" height="109" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56415" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-130016.png" alt="" width="153" height="112" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56416" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-131200.png" alt="" width="199" height="122" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56417" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-131207.png" alt="" width="209" height="116" /></td>
</tr>
<tr>
<td height="19">2 pcs/pack — threaded</td>
<td>2 pcs/pack — threaded</td>
<td>threaded</td>
<td>2 pcs/pack — threaded</td>
<td>2 pcs/pack — threaded</td>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<ul>
<li data-start="28" data-end="137">Fit checker: Simply pull the lever to perform a user seal test.</li>
<li data-start="140" data-end="226">Under-chin: Unique curve enhances the airtight seal between face and mask.</li>
<li data-start="229" data-end="347">Silicone: Soft, skin-friendly material; silicone seal provides a comfortable fit.</li>
<li data-start="350" data-end="436">HAWC Lip: Achieves high airtightness via &#8220;suction effect&#8221;; applied to full-face models.</li>
<li data-start="439" data-end="498">Size S available: Size S options for users with petite faces.</li>
<li data-start="501" data-end="620">Low breathing resistance: Employs Alpha Ring filter technology for reduced breathing effort during long shifts.</li>
<li>Speaking Diaphragm: Integrated device enables clear verbal communication while wearing the mask.</li>
<li>Activated Carbon: Effectively neutralizes low-concentration ozone; utilizes carbon-impregnated filters.</li>
<li>Surface Hardening: The visor lens is treated to resist scratches.</li>
<li>Special Surface Hardening: Advanced coating provides superior scratch protection over standard treatments.</li>
</ul>
<p><strong data-start="452" data-end="462">Note:</strong> Consumable components and filters should be replaced early and on schedule.</p>The post <a href="https://koueitrading.com/global/product/koken-1781-series-dust-mask/">Koken 1781 Series Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken 7121R-03 Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-7121r-03-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 14 Mar 2020 03:43:41 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192870</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: 7121R-03 Important Points When Wearing a Respirator Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself from inhaling dust while wearing a mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical. 1. Filter [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-7121r-03-dust-mask/">Koken 7121R-03 Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: 7121R-03</p>
<h2>Important Points When Wearing a Respirator</h2>
<p>Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself from inhaling dust while wearing a mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Using unique technology, wool fibers are electrostatically charged, allowing electrostatic force to draw particles to the fiber surface. This is the primary mechanism for collecting particles. A high-density fiber structure is unnecessary, successfully integrating the two contrasting features: &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221; It consistently maintains the highest standard of performance and quality, making it an excellent long-term filter solution.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" sizes="auto, (max-width: 317px) 100vw, 317px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png 317w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333-300x204.png 300w" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" sizes="auto, (max-width: 316px) 100vw, 316px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png 316w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322-300x227.png 300w" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applied products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the fiber density of the filter enhances collection efficiency. To meet airflow resistance standards, paper filters traditionally require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into pristine circular shapes in a single process, creating the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" sizes="auto, (max-width: 329px) 100vw, 329px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751-300x116.png 300w" alt="" width="329" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" sizes="auto, (max-width: 321px) 100vw, 321px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png 321w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803-300x227.png 300w" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applied products are from page P.8 to P.11</p>
<p data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td width="64">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the “Dust Respirator Standards”.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct-Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Aerosol</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride) particles</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate) particles</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ /min</td>
<td class="text-center" colspan="2">85 ℓ /min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement; must meet values in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" colspan="2">For NaCl test aerosol<br />
Load up to 100mg</td>
<td class="text-left" colspan="2">For DOP test aerosol<br />
Load up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or higher</td>
<td>RL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or higher</td>
<td>RL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or higher</td>
<td>RL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or higher</td>
<td>DL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or higher</td>
<td>DL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or higher</td>
<td>DL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>( ) indicates products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col">Exhalation valve operation leak test</td>
<td>– Internal pressure must drop immediately when air is sucked<br />
– The time for internal pressure to return to normal atmospheric pressure must be 15 seconds or more</td>
</tr>
<tr>
<th class="header-col"><strong>Carbon Dioxide (CO2) Concentration Increase</strong></th>
<td class="content-col" colspan="2">Using a test headform and an artificial lung to inhale/exhale air containing CO2. The difference in CO2 concentration in the inhaled air between wearing and not wearing the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space Volume</strong></th>
<td class="content-col" colspan="2">Calculated from the (Carbon Dioxide Concentration Increase Test)</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Aerosol</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">Measured at 40 ℓ/min after loading test dust at 85 ℓ/min</td>
</tr>
<tr>
<td class="header-sub">Amount loaded onto dust respirator</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Aerosol and Collection Efficiency </span><span class="bottom-left-text">Disposable Type<br />
/ Replaceable Type</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" rowspan="2"><strong>Classification</strong><br />
<strong>(Particle Collection Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender"><strong>Test aerosol is solid Sodium Chloride (NaCl)</strong></th>
<th class="bg-lavender"><strong>Test aerosol is liquid Dioctyl Phthalate (DOP)</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
</tbody>
</table>
<h2>High Efficiency Filter + Face-Friendly Surface</h2>
<h3>2. Surface Engineering for a Better Facial Fit</h3>
<p>Even if a dust mask has a high collection efficiency filter, it is meaningless if dust leaks through the facepiece seal during use. This is primarily caused by a &#8220;gap at the face contact area when worn.&#8221; We consider the fit of the mask to be as important as the filter performance. Therefore, our company has developed technology to enhance the airtightness of the facial contact area.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" sizes="auto, (max-width: 247px) 100vw, 247px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg 775w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-227x300.jpg 227w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-768x1015.jpg 768w" alt="" width="247" height="326" /><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and easily adapts to facial movements, ensuring wearing comfort and stability during use.</p>
<p><strong>HAWC harness strap</strong><br />
The strap design ensures a high level of fit, maximizing the &#8220;suction&#8221; effect when wearing the mask to ensure an airtight facial seal.<img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" sizes="auto, (max-width: 145px) 100vw, 145px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png 319w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014-267x300.png 267w" alt="" width="145" height="163" /></p>
<p><strong>Freeposition Underchin</strong><br />
The special shape of the facial contact area prevents dust from leaking in. By aligning the nose portion first, it accommodates various facial dimensions, providing a secure fit for a wide range of face sizes (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" sizes="auto, (max-width: 192px) 100vw, 192px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png 410w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024-300x180.png 300w" alt="" width="192" height="115" /></p>
<p><strong data-start="56" data-end="112">Fit Status of the Freeposition Underchin Facepiece</strong><br data-start="112" data-end="115" />(Cross-sectional simulation to show the contact position between the mask and the chin).</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong data-start="56" data-end="94">For large faces:</strong><br data-start="94" data-end="97" />Uses the outer section of the mask to adjust the fit around the chin.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td width="64"><strong data-start="164" data-end="202">For small faces:</strong><br data-start="202" data-end="205" />Uses the inner section of the mask to adjust the fit around the chin.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Wearing Safety</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Internal Fit Checker</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed for various face shapes; the cushion naturally fits your face.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Utilizes a 3D poly-band harness that matches head shapes to enhance the feeling of fit and seal.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>Fit checker is integrated inside, helping to check the mask seal at any time (for 1005, 1010A, 1015, 1180 series).</td>
</tr>
</tbody>
</table>
<h2 data-start="26" data-end="80"><strong data-start="26" data-end="80">Replaceable Dust Respirator – Alpha Ring Filter</strong></h2>
<p data-start="82" data-end="140"><strong data-start="82" data-end="140">Alpha Ring Filter with concentric design and compact shape</strong></p>
<p data-start="142" data-end="665" data-is-last-node="" data-is-only-node="">Paper filters that enhance particle collection efficiency by increasing fiber density often require an expanded surface area to meet airflow resistance standards.<br data-start="295" data-end="298" />The Alpha Ring filter was the first domestically developed filter using ultra-fine fibers molded into a round pleat structure.<br data-start="457" data-end="460" />Currently, by continuing to expand the filtration surface area, the filter maintains a compact shape while achieving lower breathing resistance, resulting in higher and more stable performance.</p>
<p data-start="142" data-end="665" data-is-last-node="" data-is-only-node=""><img loading="lazy" decoding="async" class="aligncenter wp-image-56406" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122720.png" sizes="auto, (max-width: 298px) 100vw, 298px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122720.png 391w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122720-300x238.png 300w" alt="" width="298" height="236" /></p>
<p data-start="26" data-end="84"><strong data-start="26" data-end="84">All Alpha Ring filters are water-repellent treated</strong></p>
<p data-start="26" data-end="84"><img loading="lazy" decoding="async" class="aligncenter wp-image-56407" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122749.png" alt="" width="168" height="140" /></p>
<p data-start="86" data-end="307">The filter is treated for water repellency to limit the adherence of mist or droplets, ensuring breathing remains easy during use.<br data-start="224" data-end="227" />Additionally, this treatment is effective against oil mist.</p>
<p data-start="314" data-end="338"><strong data-start="314" data-end="338">HAWC Lip (High Adaptable Wide Concave)</strong></p>
<p data-start="314" data-end="338"><img loading="lazy" decoding="async" class="aligncenter wp-image-56408" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122803.png" alt="" width="149" height="184" /></p>
<p data-start="340" data-end="498">The facial contact area has a wide concave surface that surrounds the face. When the harness is tightened, a suction effect is created, resulting in high airtightness.</p>
<p data-start="500" data-end="602" data-is-last-node="" data-is-only-node="">*HAWC stands for High Adaptable Wide Concave<br data-start="554" data-end="557" />*Image shown is the Model 1021H.</p>
<p data-start="500" data-end="602" data-is-last-node="" data-is-only-node=""><strong>(Head Harness Types)</strong><br data-start="46" data-end="49" />Please replace head straps periodically.</p>
<p data-start="500" data-end="602" data-is-last-node="" data-is-only-node=""><img loading="lazy" decoding="async" class=" wp-image-192866 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11-300x94.jpg" sizes="auto, (max-width: 543px) 100vw, 543px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11-300x94.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11-768x241.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11.jpg 1024w" alt="" width="543" height="170" /></p>
<h2 data-start="26" data-end="105"><strong data-start="107" data-end="133">Sakai Model 7121R-03</strong></h2>
<p data-start="26" data-end="105">The basic RL3 model manufactured by our company<br data-start="79" data-end="82" />Size S facepiece available</p>
<p data-start="138" data-end="171">Type Certification: TM644<br />
Assigned Protection Factor: 10 (RL3)</p>
<p data-start="211" data-end="293">Additionally, it can be used as a gas mask<br data-start="265" data-end="268" />(Model 7121RG · Class L3)</p>
<p data-start="296" data-end="325">Absorbent canisters sold separately<br />
Type Certification: TN237</p>
<p data-start="296" data-end="325"><img loading="lazy" decoding="async" class="aligncenter wp-image-56430" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-135542.png" alt="" width="276" height="231" /></p>
<ul>
<li data-start="390" data-end="444">Under-chin seal (improves face seal contact)</li>
<li data-start="447" data-end="485">Silicone facepiece (soft, skin-friendly)</li>
<li data-start="488" data-end="501">Size S available</li>
</ul>
<div class="table-container">
<table>
<tbody>
<tr>
<th class="col-label"><strong>Particle Collection Efficiency</strong></th>
<td class="col-value">
<div class="value-wrapper">99.9% or higher<br />
(Average 99.99%)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">85Pa or less<br />
(Average 68Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">52Pa or less<br />
(Average 30Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Resistance Increase</strong></th>
<td class="col-value">
<div class="value-wrapper">―<br />
(Average 85Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-value">
<div class="value-wrapper">172g or less<br />
(Average 157g)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Head Harness</strong></th>
<td class="col-value">RB Type</td>
</tr>
</tbody>
</table>
</div>
<p data-start="503" data-end="527">Replacement Parts:</p>
<ul>
<li data-start="530" data-end="555">Inhalation Valve (circular)</li>
<li data-start="558" data-end="583">Exhalation Valve T-6K</li>
<li data-start="586" data-end="613">Moisture Sponge (egg-shaped)</li>
</ul>
<div class="table-container">
<h3 data-start="26" data-end="61">Notes on Filter Replacement</h3>
<p data-start="88" data-end="354">As dust accumulates in the filter, airflow resistance increases, making breathing more difficult.<br data-start="201" data-end="204" />Furthermore, besides difficult breathing, if the mask is not perfectly sealed against the face, dust may enter through gaps created by the increased breathing effort.</p>
<ul>
<li data-start="358" data-end="489">Always perform a seal check before use and ensure the mask is firmly secured to the face.</li>
<li data-start="492" data-end="589">Replace the filter before breathing becomes difficult to prevent excessive airflow resistance.</li>
</ul>
<p data-start="591" data-end="705" data-is-last-node="" data-is-only-node="">*If you have any questions regarding part replacement, please contact our office or local agent.</p>
</div>
<p><strong>Replacement Filters · Optional Accessories</strong></p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong data-start="43" data-end="51">RD-6</strong> (For: 1721H, 1521H, 7121R, 7191DK)</td>
<td width="64"><strong data-start="125" data-end="134">RD-6U</strong> (For: 7191DKU, 1521U)</td>
<td width="64"><strong data-start="195" data-end="203">RD-8</strong> (For: 1180H)</td>
<td width="64"><strong data-start="240" data-end="250">LAS-52</strong> (For: 1781DW)</td>
<td width="64"><strong data-start="303" data-end="314">LAS-52C</strong> (For: 1781DWC)</td>
<td width="64"><strong>(Optional) Fit Tester – Type V</strong><br data-start="72" data-end="75" />Applied models: 1721H, 1521H, 1521U, 7121R, 7191DK, 7191DKU</td>
<td width="64"><strong>(Optional) Fit Tester – Type F</strong><br data-start="193" data-end="196" />Applied models: 1781DW, 1781DWC</td>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56411" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-125924.png" alt="" width="154" height="110" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56412" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-125934.png" alt="" width="154" height="108" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56413" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-125953.png" alt="" width="145" height="115" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56414" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-130005.png" alt="" width="142" height="109" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56415" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-130016.png" alt="" width="153" height="112" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56416" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-131200.png" alt="" width="199" height="122" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56417" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-131207.png" alt="" width="209" height="116" /></td>
</tr>
<tr>
<td height="19">2 pcs/set — Threaded</td>
<td>2 pcs/set — Threaded</td>
<td>Threaded</td>
<td>2 pcs/set — Threaded</td>
<td>2 pcs/set — Threaded</td>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<ul>
<li data-start="28" data-end="137">Fit Checker: Just operate the lever to perform a user seal check (fit test).</li>
<li data-start="140" data-end="226">Under-Chin: Unique curve enhances the airtight seal between face and mask.</li>
<li data-start="229" data-end="347">Silicone: Soft, skin-friendly material; silicone facepiece ensures comfortable long-term wear.</li>
<li data-start="350" data-end="436">HAWC Lip: High airtightness achieved through a &#8220;suction effect&#8221;; applied to full-face models.</li>
<li data-start="439" data-end="498">Size S Available: Small face size options are available for these models.</li>
<li data-start="501" data-end="620">Low Breathing Resistance: Alpha Ring filter technology allows for prolonged usage with minimal fatigue.</li>
<li>Speaking Diaphragm: Integrated device enables clear verbal communication while wearing the mask.</li>
<li>Activated Carbon: Effectively neutralizes low-concentration ozone; utilizes carbon-impregnated filters.</li>
<li>Surface Hardening: The visor lens is treated to resist scratches.</li>
<li>Special Surface Hardening: Advanced coating provides superior scratch protection over standard treatments.</li>
</ul>
<p><strong>Note:</strong> Consumable components and filters should be replaced promptly according to the maintenance schedule.</p>The post <a href="https://koueitrading.com/global/product/koken-7121r-03-dust-mask/">Koken 7121R-03 Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken 7191 Series Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-7191-series-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 14 Mar 2020 03:40:28 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192868</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: 7191 Series Important Points When Wearing a Respirator Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself from inhaling dust while wearing a mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical. 1. [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-7191-series-dust-mask/">Koken 7191 Series Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: 7191 Series</p>
<h2>Important Points When Wearing a Respirator</h2>
<p>Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself from inhaling dust while wearing a mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Using unique technology, wool fibers are electrostatically charged, allowing electrostatic force to draw particles to the fiber surface. This is the primary mechanism for capturing particles. A high-density fiber structure is unnecessary, successfully integrating the two contrasting features: &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221; It consistently maintains the highest standard of performance and quality, making it an excellent long-term filter solution.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" sizes="auto, (max-width: 317px) 100vw, 317px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png 317w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333-300x204.png 300w" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" sizes="auto, (max-width: 316px) 100vw, 316px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png 316w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322-300x227.png 300w" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applied products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the fiber density of the filter enhances collection efficiency. To meet airflow resistance standards, paper filters traditionally require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into pristine circular shapes in a single process, creating the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" sizes="auto, (max-width: 329px) 100vw, 329px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751-300x116.png 300w" alt="" width="329" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" sizes="auto, (max-width: 321px) 100vw, 321px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png 321w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803-300x227.png 300w" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applied products are from page P.8 to P.11</p>
<p data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td width="64">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the “Dust Respirator Standards”.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct-Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Particles</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ /min</td>
<td class="text-center" colspan="2">85 ℓ /min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement; must meet values in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" colspan="2">For NaCl particles<br />
Load up to 100mg</td>
<td class="text-left" colspan="2">For DOP particles<br />
Load up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or higher</td>
<td>RL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or higher</td>
<td>RL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or higher</td>
<td>RL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or higher</td>
<td>DL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or higher</td>
<td>DL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or higher</td>
<td>DL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>Values in ( ) are for products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col">Exhalation valve operation leak test</td>
<td>– Internal pressure must drop immediately during suction.<br />
– Time for internal pressure to return to normal must be 15 seconds or more.</td>
</tr>
<tr>
<th class="header-col"><strong>Carbon Dioxide (CO2) Concentration Increase</strong></th>
<td class="content-col" colspan="2">Measured using a test headform and artificial lung. The difference in CO2 concentration in inhaled air with and without the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space</strong></th>
<td class="content-col" colspan="2">Value calculated from the CO2 Concentration Increase Test.</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Particles</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">After dust accumulation at 85 ℓ/min, measurement is taken at 40 ℓ/min.</td>
</tr>
<tr>
<td class="header-sub">Dust Accumulation Amount</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Aerosol and Collection Efficiency </span><span class="bottom-left-text">Disposable Type<br />
/ Replaceable Type</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" rowspan="2"><strong>Classification</strong><br />
<strong>(Particle Collection Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender"><strong>Test aerosol is solid Sodium Chloride (NaCl)</strong></th>
<th class="bg-lavender"><strong>Test aerosol is liquid Dioctyl Phthalate (DOP)</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
</tbody>
</table>
<h2>High-Performance Filter + Facepiece Designed for Easy Fit</h2>
<h3>2. Facepiece Fit Technology</h3>
<p>Even if a dust respirator has a high collection efficiency filter, it is meaningless if dust leaks through the face-to-mask seal during use. This is primarily caused by a &#8220;gap at the face contact area when worn.&#8221; We consider the fit of the mask to be as important as the filter performance. Therefore, our company has developed technologies to enhance the airtightness of the facepiece seal.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" sizes="auto, (max-width: 247px) 100vw, 247px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg 775w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-227x300.jpg 227w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-768x1015.jpg 768w" alt="" width="247" height="326" /><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and effortlessly adapts to body movements, ensuring a comfortable fit and stability during use.</p>
<p><strong>HAWC Lip Structure</strong><br />
The lip design ensures a high degree of adhesion, maximizing the &#8220;suction cup&#8221; effect when wearing the mask to ensure an airtight facial seal.<img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" sizes="auto, (max-width: 145px) 100vw, 145px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png 319w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014-267x300.png 267w" alt="" width="145" height="163" /></p>
<p><strong>Free Position Under Chin</strong><br />
The unique curve of the face contact area prevents dust from leaking in. By aligning the nose portion first, it accommodates various facial dimensions, providing a secure fit for a wide range of face sizes (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" sizes="auto, (max-width: 192px) 100vw, 192px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png 410w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024-300x180.png 300w" alt="" width="192" height="115" /></p>
<p><strong data-start="56" data-end="112">Fit Status of the Free Position Under Chin Mask</strong><br data-start="112" data-end="115" />(Simulated image with the mask cut away to clearly show where it contacts the chin).</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong data-start="56" data-end="94">For individuals with large faces:</strong><br data-start="94" data-end="97" />The outer section of the mask rests naturally against the chin to provide a proper fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td width="64"><strong data-start="164" data-end="202">For individuals with small faces:</strong><br data-start="202" data-end="205" />The inner section of the mask naturally positions itself against the chin to secure the fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Wearing Stability</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Built-in Fit Checker</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed to naturally conform to various facial sizes and shapes, providing a seamless fit.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Uses a 3D-shaped polyband harness that conforms to the shape of the head, enhancing fit and sealing performance.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>A built-in fit checker allows you to test the mask&#8217;s seal at any time (available for the 1005, 1010A, 1015, and 1180 series).</td>
</tr>
</tbody>
</table>
<p data-start="36" data-end="48"><strong data-start="31" data-end="55">Head Harness Types</strong><br data-start="55" data-end="58" />Please replace the head straps periodically.</p>
<p data-start="36" data-end="48"><img loading="lazy" decoding="async" class=" wp-image-192866 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11-300x94.jpg" sizes="auto, (max-width: 543px) 100vw, 543px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11-300x94.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11-768x241.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11.jpg 1024w" alt="" width="543" height="170" /></p>
<h2 data-start="72" data-end="132"><strong data-start="134" data-end="165">Sakai Model 7191DK-03</strong></h2>
<p data-start="72" data-end="132">Equipped with a speaking diaphragm for clear communication and instructions.</p>
<p data-start="134" data-end="241">RL3 Classification<br data-start="165" data-end="168" />Type Certification: TM645<br data-start="209" data-end="212" />Assigned Protection Factor: 10</p>
<p data-start="243" data-end="381">Can be used as a gas mask (Model 7191DKG · Class L3)<br data-start="307" data-end="310" />(Absorbent canisters sold separately)<br data-start="337" data-end="340" />Type Certification: TN179</p>
<p data-start="243" data-end="381"><img loading="lazy" decoding="async" class="aligncenter wp-image-56433" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-141105.png" alt="" width="290" height="240" /></p>
<ul>
<li data-start="412" data-end="426">Under Chin Cushion</li>
<li data-start="429" data-end="451">Silicone Facepiece</li>
<li data-start="454" data-end="468">Speaking Diaphragm</li>
</ul>
<div class="spec-table-container">
<table class="spec-table">
<tbody>
<tr>
<th class="col-label"><strong>Particle Collection Efficiency</strong></th>
<td class="col-value">
<div class="value-wrapper">99.9% or more<br />
(Average 99.99%)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">85Pa or less<br />
(Average 69Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">35Pa or less<br />
(Average 18Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Resistance Increase</strong></th>
<td class="col-value">
<div class="value-wrapper">―<br />
(Average 84Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-value">
<div class="value-wrapper">198g or less<br />
(Average 183g)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Head Harness</strong></th>
<td class="col-value">XDB Type</td>
</tr>
</tbody>
</table>
</div>
<p data-start="470" data-end="494">Replacement Parts:</p>
<ul>
<li data-start="497" data-end="518">Inhalation Valve (Circular)</li>
<li data-start="521" data-end="535">Exhalation Valve T-1K</li>
<li data-start="538" data-end="563">Egg-shaped Moisture Sponge</li>
</ul>
<h2 data-start="570" data-end="611"><strong data-start="730" data-end="762">Sakai Model 7191DKU-02</strong></h2>
<p data-start="570" data-end="611">Suitable for nanomaterial handling.<br />
Particle collection efficiency: 99.999% (average value).<br />
Equipped with a speaking diaphragm allowing conversation while wearing the mask.</p>
<p data-start="730" data-end="838">RL3 Classification<br />
Type Certification: TM674<br data-start="806" data-end="809" />Assigned Protection Factor: 10</p>
<p data-start="730" data-end="838"><img loading="lazy" decoding="async" class="aligncenter wp-image-56434" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-141124.png" alt="" width="289" height="239" /></p>
<ul>
<li data-start="869" data-end="883">Under Chin Cushion</li>
<li data-start="886" data-end="908">Silicone Facepiece</li>
<li data-start="911" data-end="925">Speaking Diaphragm</li>
</ul>
<div class="table-title">
<table class="spec-table">
<tbody>
<tr>
<th class="col-label"><strong>Particle Collection Efficiency</strong></th>
<td class="col-value">
<div class="value-wrapper">99.99% or more<br />
(Average 99.999%)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">105Pa or less<br />
(Average 69Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">35Pa or less<br />
(Average 20Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Resistance Increase</strong></th>
<td class="col-value">
<div class="value-wrapper">―<br />
(Average 85Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-value">
<div class="value-wrapper">203g or less<br />
(Average 183g)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Head Harness</strong></th>
<td class="col-value">XDB Type</td>
</tr>
</tbody>
</table>
</div>
<p data-start="927" data-end="951">Replacement Parts:</p>
<ul>
<li data-start="954" data-end="975">Inhalation Valve (Circular)</li>
<li data-start="978" data-end="992">Exhalation Valve T-1K</li>
<li data-start="995" data-end="1020">Egg-shaped Moisture Sponge</li>
</ul>
<div class="table-container">
<h3 data-start="26" data-end="61">Notes on Filter Replacement</h3>
<p data-start="88" data-end="354">As dust accumulates in the filter, airflow resistance increases, making breathing more difficult. Furthermore, if the mask is not perfectly sealed against the face, dust may enter through gaps created by the increased breathing effort.</p>
<ul>
<li data-start="358" data-end="489">Always perform a seal check before use and ensure the mask is firmly secured to the face.</li>
<li data-start="492" data-end="589">Replace the filter before breathing becomes difficult to prevent excessive airflow resistance.</li>
</ul>
<p data-start="591" data-end="705" data-is-last-node="" data-is-only-node="">*If you have any questions regarding part replacement, please contact our office or local agent.</p>
</div>
<p><strong>Replacement Filters · Optional Accessories</strong></p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong data-start="43" data-end="51">RD-6</strong> (For: 1721H, 1521H, 7121R, 7191DK)</td>
<td width="64"><strong data-start="125" data-end="134">RD-6U</strong> (For: 7191DKU, 1521U)</td>
<td width="64"><strong data-start="195" data-end="203">RD-8</strong> (For: 1180H)</td>
<td width="64"><strong data-start="240" data-end="250">LAS-52</strong> (For: 1781DW)</td>
<td width="64"><strong data-start="303" data-end="314">LAS-52C</strong> (For: 1781DWC)</td>
<td width="64"><strong data-start="28" data-end="72">(Optional) Fit Tester – Type V</strong><br data-start="72" data-end="75" />Applied models: 1721H, 1521H, 1521U, 7121R, 7191DK, 7191DKU</td>
<td width="64"><strong data-start="149" data-end="193">(Optional) Fit Tester – Type F</strong><br data-start="193" data-end="196" />Applied models: 1781DW, 1781DWC</td>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56411" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-125924.png" alt="" width="154" height="110" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56412" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-125934.png" alt="" width="154" height="108" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56413" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-125953.png" alt="" width="145" height="115" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56414" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-130005.png" alt="" width="142" height="109" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56415" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-130016.png" alt="" width="153" height="112" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56416" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-131200.png" alt="" width="199" height="122" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56417" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-131207.png" alt="" width="209" height="116" /></td>
</tr>
<tr>
<td height="19">2 pcs/set — Threaded</td>
<td>2 pcs/set — Threaded</td>
<td>Threaded</td>
<td>2 pcs/set — Threaded</td>
<td>2 pcs/set — Threaded</td>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<ul>
<li data-start="28" data-end="137">Fit Checker: Just operate the lever to perform a user seal check (fit test).</li>
<li data-start="140" data-end="226">Under-Chin: Unique curve enhances the airtight seal between face and mask.</li>
<li data-start="229" data-end="347">Silicone: Soft, skin-friendly material; silicone facepiece ensures comfortable long-term wear.</li>
<li data-start="350" data-end="436">HAWC Lip: High airtightness achieved through a &#8220;suction effect&#8221;; applied to full-face models.</li>
<li data-start="439" data-end="498">Size S Available: Small face size options are available for these models.</li>
<li data-start="501" data-end="620">Low Breathing Resistance: Alpha Ring filter technology allows for prolonged usage with minimal fatigue.</li>
<li>Speaking Diaphragm: Integrated device enables clear verbal communication while wearing the mask.</li>
<li>Activated Carbon: Effectively neutralizes low-concentration ozone; utilizes carbon-impregnated filters.</li>
<li>Surface Hardening: The visor lens is treated to resist scratches.</li>
<li>Special Surface Hardening: Advanced coating provides superior scratch protection over standard treatments.</li>
</ul>
<p><strong>Note:</strong> Consumable components and filters should be replaced promptly according to the maintenance schedule.</p>The post <a href="https://koueitrading.com/global/product/koken-7191-series-dust-mask/">Koken 7191 Series Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken 1180H Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-1180h-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 14 Mar 2020 03:29:15 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192857</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: 1180H Important points when wearing a mask Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself from inhaling dust while wearing a mask, the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical. 1. Filter Technology [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-1180h-dust-mask/">Koken 1180H Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: 1180H</p>
<h2>Important points when wearing a mask</h2>
<p>Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself from inhaling dust while wearing a mask, the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Using unique technology, wool fibers are electrostatically charged, allowing electrostatic force to draw particles to the fiber surface. This is the primary mechanism for capturing particles. A high-density fiber structure is unnecessary, successfully integrating the two contrasting features: &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221; It consistently maintains the highest standard of performance and quality, making it an excellent long-term filter solution.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" sizes="auto, (max-width: 317px) 100vw, 317px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png 317w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333-300x204.png 300w" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" sizes="auto, (max-width: 316px) 100vw, 316px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png 316w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322-300x227.png 300w" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applied products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the fiber density of the filter enhances collection efficiency. To meet airflow resistance standards, paper filters traditionally require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into pristine circular shapes in a single process, creating the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" sizes="auto, (max-width: 329px) 100vw, 329px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751-300x116.png 300w" alt="" width="329" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" sizes="auto, (max-width: 321px) 100vw, 321px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png 321w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803-300x227.png 300w" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applied products are from page P.8 to P.11</p>
<p data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td width="64">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the “Dust Respirator Standards”.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct-Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Particles</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ /min</td>
<td class="text-center" colspan="2">85 ℓ /min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement; must meet values in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" colspan="2">For NaCl particles<br />
Load up to 100mg</td>
<td class="text-left" colspan="2">For DOP particles<br />
Load up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or higher</td>
<td>RL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or higher</td>
<td>RL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or higher</td>
<td>RL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or higher</td>
<td>DL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or higher</td>
<td>DL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or higher</td>
<td>DL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>Values in ( ) are for products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col">Exhalation valve leak test</td>
<td>– Internal pressure must drop immediately during suction.<br />
– Time for internal pressure to return to normal must be 15 seconds or more.</td>
</tr>
<tr>
<th class="header-col"><strong>CO2 Concentration Increase</strong></th>
<td class="content-col" colspan="2">Measured using a test headform and artificial lung. The difference in CO2 concentration in inhaled air with and without the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space</strong></th>
<td class="content-col" colspan="2">Value calculated from the CO2 Concentration Increase Test.</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Particles</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">After dust accumulation at 85 ℓ/min, measurement is taken at 40 ℓ/min.</td>
</tr>
<tr>
<td class="header-sub">Dust Accumulation Amount</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Particles &amp; Efficiency </span><span class="bottom-left-text">Disposable / Replaceable</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" rowspan="2"><strong>Classification</strong><br />
<strong>(Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender"><strong>Test particle: Solid NaCl</strong></th>
<th class="bg-lavender"><strong>Test particle: Liquid DOP</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (≥ 80.0%)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (≥ 95.0%)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (≥ 99.9%)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (≥ 80.0%)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (≥ 95.0%)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (≥ 99.9%)</td>
</tr>
</tbody>
</table>
<h2>High Efficiency Filter + Face-Friendly Surface</h2>
<h3>2. Surface Engineering for a Better Facial Fit</h3>
<p>Even if a dust mask has a high collection efficiency filter, it is useless if dust leaks in through the facepiece seal. The primary cause of leakage is the “gap at the contact area when wearing the mask.” We consider the fit of the mask to be as important as the filter performance. Therefore, our company has developed technology to enhance the airtightness of the facial contact area.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" sizes="auto, (max-width: 247px) 100vw, 247px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg 775w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-227x300.jpg 227w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-768x1015.jpg 768w" alt="" width="247" height="326" /><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and easily adapts to body movements, ensuring wearing comfort and stability during use.</p>
<p><strong>HAWC harness strap</strong><br />
The strap design ensures a high level of fit, maximizing the &#8220;suction&#8221; effect when wearing the mask to ensure an airtight seal on the face.<img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" sizes="auto, (max-width: 145px) 100vw, 145px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png 319w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014-267x300.png 267w" alt="" width="145" height="163" /></p>
<p><strong>Freeposition Underchin</strong><br />
The special shape of the facial contact area prevents dust entry. The nose section is adjustable for different sizes, ensuring a perfect fit for a wide range of facial dimensions (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" sizes="auto, (max-width: 192px) 100vw, 192px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png 410w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024-300x180.png 300w" alt="" width="192" height="115" /></p>
<p><strong data-start="56" data-end="112">Fit Status of the Freeposition Underchin Facepiece</strong><br data-start="112" data-end="115" />(Cross-sectional simulation to show the contact position between the mask and the chin).</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong data-start="56" data-end="94">For large faces:</strong><br data-start="94" data-end="97" />Uses the outer section of the mask to adjust the fit around the chin.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td width="64"><strong data-start="164" data-end="202">For small faces:</strong><br data-start="202" data-end="205" />Uses the inner section of the mask to adjust the fit around the chin.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Wearing Safety</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Internal Fit Checker</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed for various face shapes; the cushion naturally fits your face.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Utilizes a 3D poly-band harness that matches head shapes to enhance the feeling of fit and seal.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>Fit checker is integrated inside, helping to check the mask seal at any time (for 1005, 1010A, 1015, 1180 series).</td>
</tr>
</tbody>
</table>
<h2 data-start="26" data-end="80"><strong data-start="26" data-end="80">Replaceable Dust Respirator – Alpha Ring Filter</strong></h2>
<p data-start="82" data-end="140"><strong data-start="82" data-end="140">Alpha Ring Filter with concentric design and compact shape</strong></p>
<p data-start="142" data-end="665" data-is-last-node="" data-is-only-node="">Paper filters that enhance particle collection efficiency by increasing fiber density often require an expanded surface area to meet airflow resistance standards.<br data-start="295" data-end="298" />The Alpha Ring filter was the first domestically developed filter using ultra-fine fibers molded into a round pleat structure.<br data-start="457" data-end="460" />Currently, by continuing to expand the filtration surface area, the filter maintains a compact shape while achieving lower breathing resistance, resulting in higher and more stable performance.</p>
<p data-start="142" data-end="665" data-is-last-node="" data-is-only-node=""><img loading="lazy" decoding="async" class="aligncenter wp-image-56406" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122720.png" sizes="auto, (max-width: 298px) 100vw, 298px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122720.png 391w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122720-300x238.png 300w" alt="" width="298" height="236" /></p>
<p data-start="26" data-end="84"><strong data-start="26" data-end="84">All Alpha Ring filters are water-repellent treated</strong></p>
<p data-start="26" data-end="84"><img loading="lazy" decoding="async" class="aligncenter wp-image-56407" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122749.png" alt="" width="168" height="140" /></p>
<p data-start="86" data-end="307">The filter is treated for water repellency to limit the adherence of mist or droplets, ensuring breathing remains easy during use.<br data-start="224" data-end="227" />Additionally, this treatment is effective against oil mist.</p>
<p data-start="314" data-end="338"><strong data-start="314" data-end="338">HAWC Lip (High Adaptable Wide Concave)</strong></p>
<p data-start="314" data-end="338"><img loading="lazy" decoding="async" class="aligncenter wp-image-56408" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-122803.png" alt="" width="149" height="184" /></p>
<p data-start="340" data-end="498">The facial contact area has a wide concave surface that surrounds the face. When the harness is tightened, a suction effect is created, resulting in high airtightness.</p>
<p data-start="500" data-end="602" data-is-last-node="" data-is-only-node="">*HAWC stands for High Adaptable Wide Concave.<br data-start="554" data-end="557" />*Image shown is the Model 1021H.</p>
<p data-start="500" data-end="602" data-is-last-node="" data-is-only-node=""><strong>(Head Harness Types)</strong><br data-start="46" data-end="49" />Please replace head straps periodically.</p>
<p data-start="500" data-end="602" data-is-last-node="" data-is-only-node=""><img loading="lazy" decoding="async" class=" wp-image-192866 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11-300x94.jpg" alt="" width="543" height="170" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11-300x94.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11-768x241.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-11.jpg 1024w" sizes="auto, (max-width: 543px) 100vw, 543px" /></p>
<h2 data-start="72" data-end="138">Sakai Model 1180H</h2>
<p data-start="72" data-end="138">The company&#8217;s basic RL3 model – lightweight at only 114 g</p>
<p data-start="139" data-end="214">Built-in seal check lever (Fit Checker)<br data-start="185" data-end="188" />Size S available</p>
<p data-start="216" data-end="319">RL3 Rating<br data-start="243" data-end="246" />Model Assay Certificate: TM788<br data-start="287" data-end="290" />Assigned Protection Factor: 10</p>
<p data-start="321" data-end="443">Can be used as a gas mask with G-7 configuration<br data-start="369" data-end="372" />(Absorbent canisters sold separately)<br data-start="399" data-end="402" />Gas Mask Certificate: TN382</p>
<p data-start="321" data-end="443"><img loading="lazy" decoding="async" class="aligncenter wp-image-56437" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-141822.png" alt="" width="266" height="279" /></p>
<ul>
<li data-start="475" data-end="510">Fit Checker (Integrated seal test lever)</li>
<li data-start="513" data-end="527">Under-Chin Ergonomics</li>
<li data-start="530" data-end="552">Silicone Seal</li>
<li data-start="555" data-end="564">Size S available</li>
</ul>
<div class="spec-table-container">
<table class="spec-table">
<tbody>
<tr>
<th class="col-label"><strong>Particle Collection Efficiency</strong></th>
<td class="col-value">
<div class="value-wrapper">99.9% or higher<br />
(Average 99.99%)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">88Pa or less<br />
(Average 69Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">45Pa or less<br />
(Average 30Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance Increase</strong></th>
<td class="col-value">
<div class="value-wrapper">―<br />
(Average 89Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-value">
<div class="value-wrapper">134g or less<br />
(Average 114g)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Harness</strong></th>
<td class="col-value">RB Type</td>
</tr>
</tbody>
</table>
</div>
<p data-start="566" data-end="581">Option: Moisture Sponge Type A</p>
<p data-start="605" data-end="629">Replacement Parts:</p>
<ul>
<li data-start="632" data-end="654">Inhalation Valve: Small 03 type</li>
<li data-start="657" data-end="675">Exhalation Valve: T-7 type</li>
</ul>
<div class="table-container">
<h3 data-start="26" data-end="61">Notes on Filter Replacement</h3>
<p data-start="88" data-end="354">As dust accumulates in the filter, breathing resistance increases, making respiration more difficult.<br data-start="201" data-end="204" />Furthermore, besides difficult breathing, if the mask does not fit perfectly against the face, dust can bypass the filter through any gaps.</p>
<ul>
<li data-start="358" data-end="489">Always perform a seal check before use and ensure the mask is firmly secured to your face.</li>
<li data-start="492" data-end="589">Replace the filter before breathing becomes difficult to prevent excessive resistance buildup.</li>
</ul>
<p data-start="591" data-end="705" data-is-last-node="" data-is-only-node="">*If you have any questions regarding replacement, please contact our office or local distributor.</p>
</div>
<p><strong>Replacement Filters · Optional Accessories</strong></p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong data-start="43" data-end="51">RD-6</strong> (for: 1721H, 1521H, 7121R, 7191DK)</td>
<td width="64"><strong data-start="125" data-end="134">RD-6U</strong> (for: 7191DKU, 1521U)</td>
<td width="64"><strong data-start="195" data-end="203">RD-8</strong> (for: 1180H)</td>
<td width="64"><strong data-start="240" data-end="250">LAS-52</strong> (for: 1781DW)</td>
<td width="64"><strong data-start="303" data-end="314">LAS-52C</strong> (for: 1781DWC)</td>
<td width="64"><strong>(Optional) Fit Test Device – Type V</strong><br data-start="72" data-end="75" />Applied to models: 1721H, 1521H, 1521U, 7121R, 7191DK, 7191DKU</td>
<td width="64"><strong>(Optional) Fit Test Device – Type F</strong><br data-start="193" data-end="196" />Applied to models: 1781DW, 1781DWC</td>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56411" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-125924.png" alt="" width="154" height="110" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56412" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-125934.png" alt="" width="154" height="108" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56413" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-125953.png" alt="" width="145" height="115" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56414" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-130005.png" alt="" width="142" height="109" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56415" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-130016.png" alt="" width="153" height="112" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56416" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-131200.png" alt="" width="199" height="122" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56417" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-131207.png" alt="" width="209" height="116" /></td>
</tr>
<tr>
<td height="19">2 pcs/set — screw connection</td>
<td>2 pcs/set — screw connection</td>
<td>screw connection</td>
<td>2 pcs/set — screw connection</td>
<td>2 pcs/set — screw connection</td>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<ul>
<li data-start="28" data-end="137">Fit Checker: Simply pull the lever to perform a user seal test.</li>
<li data-start="140" data-end="226">Under-Chin: Unique curved shape enhances the seal between face and mask.</li>
<li data-start="229" data-end="347">Silicone: Soft, skin-friendly material; silicone seal provides a comfortable fit.</li>
<li data-start="350" data-end="436">HAWC Lip: Achieves high airtightness via &#8220;suction effect&#8221;; applied to full-face models.</li>
<li data-start="439" data-end="498">Size S available: Smaller size for individuals with petite faces.</li>
<li data-start="501" data-end="620">Low breathing resistance: Uses Alpha Ring filters for reduced breathing effort during long-term use.</li>
<li>Speaking Diaphragm: Facilitates clear communication and verbal instructions without mask removal.</li>
<li>Activated Carbon: Simultaneously removes low-concentration ozone; utilizes carbon-impregnated filters.</li>
<li>Surface Hardening: Visor surface is treated to resist scratches.</li>
<li>Special Surface Hardening: Enhanced scratch protection compared to standard hardening treatments.</li>
</ul>
<p><strong>Note:</strong> Consumable components and filters should be replaced early and on schedule.</p>
<p>Would you like me to explain the differences between the RL2 and RL3 classifications mentioned in this document?</p>The post <a href="https://koueitrading.com/global/product/koken-1180h-dust-mask/">Koken 1180H Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken 1181 Series Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-1181-series-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 14 Mar 2020 03:26:44 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192854</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: 1181 Series Important points when wearing a mask Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself from inhaling particles while wearing a dust mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical. [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-1181-series-dust-mask/">Koken 1181 Series Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: 1181 Series</p>
<h2>Important points when wearing a mask</h2>
<p>Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself from inhaling particles while wearing a dust mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Using unique technology, wool fibers are electrostatically charged, allowing electrostatic force to draw particles to the fiber surface. This is the primary mechanism for collecting particles. A high-density fiber structure is unnecessary, successfully integrating the two contrasting features: &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221; It consistently maintains the highest standard of performance and quality, making it an excellent long-term filter solution.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" sizes="auto, (max-width: 317px) 100vw, 317px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png 317w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333-300x204.png 300w" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" sizes="auto, (max-width: 316px) 100vw, 316px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png 316w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322-300x227.png 300w" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applied products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the fiber density of the filter enhances collection efficiency. To meet airflow resistance standards, paper filters traditionally require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into pristine circular shapes in a single process, creating the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" sizes="auto, (max-width: 329px) 100vw, 329px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751-300x116.png 300w" alt="" width="329" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" sizes="auto, (max-width: 321px) 100vw, 321px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png 321w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803-300x227.png 300w" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applied products are from page P.8 to P.11</p>
<p data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td width="64">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the “Dust Respirator Standards”.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct-Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Particles</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ /min</td>
<td class="text-center" colspan="2">85 ℓ /min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement; must meet values in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" colspan="2">For NaCl particles<br />
Load up to 100mg</td>
<td class="text-left" colspan="2">For DOP particles<br />
Load up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or higher</td>
<td>RL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or higher</td>
<td>RL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or higher</td>
<td>RL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or higher</td>
<td>DL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or higher</td>
<td>DL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or higher</td>
<td>DL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>Values in ( ) are for products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col">Exhalation valve leak test</td>
<td>– Internal pressure must drop immediately during suction.<br />
– Time for internal pressure to return to normal must be 15 seconds or more.</td>
</tr>
<tr>
<th class="header-col"><strong>CO2 Concentration Increase</strong></th>
<td class="content-col" colspan="2">Measured using a test headform and artificial lung. The difference in CO2 concentration in inhaled air with and without the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space</strong></th>
<td class="content-col" colspan="2">Value calculated from the CO2 Concentration Increase Test.</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Particles</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">After dust accumulation at 85 ℓ/min, measurement is taken at 40 ℓ/min.</td>
</tr>
<tr>
<td class="header-sub">Dust Accumulation Amount</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Particles &amp; Efficiency </span><span class="bottom-left-text">Disposable / Replaceable</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" rowspan="2"><strong>Classification</strong><br />
<strong>(Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender"><strong>Test particle: Solid NaCl</strong></th>
<th class="bg-lavender"><strong>Test particle: Liquid DOP</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (≥ 80.0%)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (≥ 95.0%)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (≥ 99.9%)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (≥ 80.0%)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (≥ 95.0%)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (≥ 99.9%)</td>
</tr>
</tbody>
</table>
<h2>High Efficiency Filter + Face-Friendly Surface</h2>
<h3>2. Surface Engineering for a Better Facial Fit</h3>
<p>Even if a dust mask has a high collection efficiency filter, it is useless if dust leaks in through the facepiece seal. The primary cause of leakage is the “gap at the contact area when wearing the mask.” We consider the fit of the mask to be as important as the filter performance. Therefore, our company has developed technology to enhance the airtightness of the facial contact area.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" sizes="auto, (max-width: 247px) 100vw, 247px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg 775w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-227x300.jpg 227w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-768x1015.jpg 768w" alt="" width="247" height="326" /></p>
<p><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and easily adapts to body movements, ensuring wearing comfort and stability during use.</p>
<p><strong>HAWC Harness</strong><br />
The harness design ensures high tension and maximizes the “suction” effect when wearing the mask, guaranteeing an airtight seal on the face.<img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" sizes="auto, (max-width: 145px) 100vw, 145px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png 319w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014-267x300.png 267w" alt="" width="145" height="163" /></p>
<p><strong>Freeposition Underchin</strong><br />
The special shape of the facial contact area prevents dust entry. The nose section is adjustable for different sizes, ensuring a perfect fit for a wide range of facial dimensions (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" sizes="auto, (max-width: 192px) 100vw, 192px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png 410w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024-300x180.png 300w" alt="" width="192" height="115" /></p>
<p><strong data-start="56" data-end="112">Fit Status of the Freeposition Underchin Facepiece</strong><br data-start="112" data-end="115" />(Cross-sectional simulation to show the contact position between the mask and the chin).</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong>For large faces:</strong><br data-start="94" data-end="97" />Uses the outer section of the mask to adjust the fit around the chin.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td width="64"><strong>For small faces:</strong><br data-start="202" data-end="205" />Uses the inner section of the mask to adjust the fit around the chin.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Wearing Safety</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Internal Fit Checker</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed for various face shapes; the cushion naturally fits your face.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Utilizes a 3D poly-band harness that matches head shapes to enhance the feeling of fit and seal.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>Built-in fit checker allows for seal checks at any time (for models 1005, 1010A, 1015, 1180 series).</td>
</tr>
</tbody>
</table>
<p data-start="36" data-end="48"><strong>Head Strap Types</strong><br data-start="55" data-end="58" />Please replace the head straps periodically.</p>
<p data-start="36" data-end="48"><img loading="lazy" decoding="async" class="size-medium wp-image-192603 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2-300x187.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2-300x187.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2-768x478.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2.jpg 1024w" alt="" width="300" height="187" /></p>
<h2 data-start="160" data-end="185"><strong>Sakaki – Model 1181R-03</strong></h2>
<p data-start="49" data-end="158">RL2 Classification<br />
Low inhalation resistance: 37 Pa<br data-start="81" data-end="84" />Dual filter type, suitable for long work hours.</p>
<p data-start="190" data-end="219">Model Assay Certificate: TM224<br />
Assigned Protection Factor: 10</p>
<p data-start="190" data-end="219"><img loading="lazy" decoding="async" class="aligncenter wp-image-56440" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-151707.png" alt="" width="292" height="235" /></p>
<ul>
<li data-start="280" data-end="318">Undercut (Seal enhancement design)</li>
<li data-start="321" data-end="337">Silicone Facepiece</li>
<li data-start="340" data-end="363">Low Respiratory Resistance</li>
<li data-start="366" data-end="377">Size S Available</li>
</ul>
<table class="spec-table">
<tbody>
<tr>
<th class="col-label"><strong>Particle Collection Efficiency</strong></th>
<td class="col-value">
<div class="value-wrapper">95.0% or higher<br />
(Average 99.4%)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">50Pa or less<br />
(Average 37Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">52Pa or less<br />
(Average 29Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance Increase</strong></th>
<td class="col-value">
<div class="value-wrapper">―<br />
(Average 45Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-value">
<div class="value-wrapper">165g or less<br />
(Average 143g)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Harness</strong></th>
<td class="col-value">RB Type</td>
</tr>
</tbody>
</table>
<p data-start="31" data-end="54">Replacement Parts: Exhalation valve: T-6K type</p>
<h2 data-start="537" data-end="563"><strong>Sakaki – Model 1181RC-02</strong></h2>
<p data-start="397" data-end="484">RL2 Classification<br />
Dual filter type, low inhalation resistance<br data-start="437" data-end="440" />Uses activated carbon blended filters.</p>
<p data-start="486" data-end="535"><strong>Danger:</strong> This is not a dedicated gas mask for high concentrations.</p>
<p data-start="568" data-end="597">Model Assay Certificate: TM230<br />
Assigned Protection Factor: 10</p>
<p data-start="568" data-end="597"><img loading="lazy" decoding="async" class="aligncenter wp-image-56441" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-151716.png" alt="" width="292" height="237" /></p>
<ul>
<li data-start="658" data-end="696">Undercut (Seal enhancement design)</li>
<li data-start="699" data-end="715">Silicone Facepiece</li>
<li data-start="718" data-end="729">Size S Available</li>
<li data-start="732" data-end="755">Low Respiratory Resistance</li>
<li data-start="758" data-end="772">Activated Carbon</li>
</ul>
<div class="table-title">
<table class="spec-table">
<tbody>
<tr>
<th class="col-label"><strong>Particle Collection Efficiency</strong></th>
<td class="col-value">
<div class="value-wrapper">95.0% or higher<br />
(Average 99.0%)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">50Pa or less<br />
(Average 35Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">52Pa or less<br />
(Average 31Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance Increase</strong></th>
<td class="col-value">
<div class="value-wrapper">―<br />
(Average 41Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-value">
<div class="value-wrapper">165g or less<br />
(Average 141g)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Harness</strong></th>
<td class="col-value">RB Type</td>
</tr>
</tbody>
</table>
<p>Replacement Parts: Exhalation valve: T-6K type</p>
<p data-start="31" data-end="77"><strong>▲ Shared Replacement Parts for 6 Models (1181R-03, 1121R-08, 1191SD-03, etc.)</strong></p>
<ul>
<li data-start="80" data-end="104">Inhalation valve: circular type</li>
<li data-start="107" data-end="139">Moisture sponge: oval type</li>
</ul>
<p data-start="151" data-end="154"><strong>Note:</strong><br />
When using 1181RC or 1180C for welding or grinding where sparks or spatter occur, it is mandatory to install the dedicated inhalation port cover (sold separately) before use.</p>
<h3>Replacement Filters · Optional Accessories</h3>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><strong>LAS-52</strong> <em>(for Model 1181R)</em></td>
<td style="width: 48pt;" width="64"><strong>LAS-52C</strong> <em>(for Model 1181RC)</em></td>
<td style="width: 48pt;" width="64"><strong>LAS-1</strong> <em>(for Models 1121R, 1121RX, 1191SD, 1191D)</em></td>
<td style="width: 48pt;" width="64"><strong>LAS-51</strong> <em>(for Model 1180)</em></td>
<td style="width: 48pt;" width="64"><strong>LAS-51C</strong> <em>(for Model 1180C)</em></td>
<td style="width: 48pt;" width="64"><strong>KBC Filter for 1121 / 1191</strong><br data-start="68" data-end="71" /><em>(Ozone &amp; organic odor removal – pack of 5)</em><br data-start="118" data-end="121" />For: 1121R / 1121RX / 1191SD / 1191D / 1122R<br data-start="184" data-end="187" />(Optional)</td>
<td style="width: 48pt;" width="64"><strong>Fit Test Device – Type F</strong><br data-start="245" data-end="248" />For: 1181R, 1181RC, 1121R, 1121RX, 1191SD, 1191D<br data-start="315" data-end="318" />(Optional)</td>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56448" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152816-removebg-preview.png" alt="" width="175" height="122" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56447" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152823-removebg-preview.png" alt="" width="174" height="124" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56446" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152827-removebg-preview.png" alt="" width="176" height="136" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56445" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152834-removebg-preview.png" alt="" width="162" height="114" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56444" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152839-removebg-preview.png" alt="" width="155" height="123" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56443" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152848-removebg-preview.png" alt="" width="232" height="121" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56442" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152853-removebg-preview.png" alt="" width="254" height="139" /></td>
</tr>
<tr>
<td height="19">Screw-in – pack of 2</td>
<td>Screw-in – pack of 2</td>
<td>Pack of 2</td>
<td>Screw-in – pack of 2</td>
<td>Screw-in – pack of 2</td>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<ul>
<li data-start="69" data-end="170">Under Chin Design: Specialized curve enhances seal at facial contact points.</li>
<li data-start="174" data-end="309">Silicone: Soft, skin-friendly material for a comfortable wearing experience. Facepiece seal uses silicone.</li>
<li data-start="313" data-end="392">Size S Available: Size S is available for users with smaller faces.</li>
<li data-start="396" data-end="516">Low Inhalation Resistance: Uses Alpha Ring filters with low breathing resistance, allowing for long work hours.</li>
<li data-start="520" data-end="637">Speaking Diaphragm: Allows communication and commands while wearing the mask.</li>
<li data-start="641" data-end="749">Activated Carbon: Effectively removes low-concentration ozone using carbon-treated filters.</li>
<li data-start="753" data-end="867">Micron Filter: High-efficiency electrostatic filter material compliant with RL classification.</li>
<li data-start="871" data-end="999">Fit Checker: Lever mechanism for easy seal testing.</li>
</ul>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td class="xl65" style="height: 28.8pt; width: 48pt;" rowspan="2" width="64" height="38">
<p data-start="31" data-end="62"><strong>Double-Layer Bonnet Structure</strong></p>
<p data-start="64" data-end="422">The exhalation valve is shielded inside the bonnet from external factors like wind. Exhaled air accumulated in the upper bonnet acts as a barrier, preventing direct external impact and protecting the valve. This significantly improves exhalation valve performance and stability under real usage conditions.</p>
</td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56450" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447.png" alt="" width="203" height="202" /></td>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><strong>Note on Replacement</strong><br data-start="1030" data-end="1033" />Always replace filters and wearable parts promptly as recommended.</td>
</tr>
</tbody>
</table>
</div>The post <a href="https://koueitrading.com/global/product/koken-1181-series-dust-mask/">Koken 1181 Series Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken 1121 Series Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-1121-series-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 14 Mar 2020 03:22:02 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192852</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: 1121 Series Important points when wearing a mask Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself while wearing a dust mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical. 1. Filter Technology [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-1121-series-dust-mask/">Koken 1121 Series Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: 1121 Series</p>
<h2>Important points when wearing a mask</h2>
<p>Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself while wearing a dust mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Using unique technology, wool fibers are electrostatically charged, allowing electrostatic force to draw particles to the fiber surface. This is the primary mechanism for capturing particles. A high-density fiber structure is unnecessary, successfully integrating the two contrasting features: &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221; It consistently maintains the highest standard of performance and quality, making it an excellent long-term filter solution.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" sizes="auto, (max-width: 317px) 100vw, 317px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png 317w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333-300x204.png 300w" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" sizes="auto, (max-width: 316px) 100vw, 316px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png 316w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322-300x227.png 300w" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applied products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the fiber density of the filter enhances collection efficiency. To meet airflow resistance standards, paper filters traditionally require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into pristine circular shapes in a single process, creating the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" sizes="auto, (max-width: 329px) 100vw, 329px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751-300x116.png 300w" alt="" width="329" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" sizes="auto, (max-width: 321px) 100vw, 321px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png 321w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803-300x227.png 300w" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applied products are from page P.8 to P.11</p>
<p data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td width="64">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the “Dust Respirator Standards”.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct-Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Particles</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ /min</td>
<td class="text-center" colspan="2">85 ℓ /min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement; must meet values in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" colspan="2">For NaCl particles<br />
Load up to 100mg</td>
<td class="text-left" colspan="2">For DOP particles<br />
Load up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or higher</td>
<td>RL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or higher</td>
<td>RL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or higher</td>
<td>RL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or higher</td>
<td>DL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or higher</td>
<td>DL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or higher</td>
<td>DL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>Values in ( ) are for products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col">Exhalation valve leak test</td>
<td>– Internal pressure must drop immediately during suction.<br />
– Time for internal pressure to return to normal must be 15 seconds or more.</td>
</tr>
<tr>
<th class="header-col"><strong>CO2 Concentration Increase</strong></th>
<td class="content-col" colspan="2">Measured using a test headform and artificial lung. The difference in CO2 concentration in inhaled air with and without the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space</strong></th>
<td class="content-col" colspan="2">Value calculated from the CO2 Concentration Increase Test.</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Particles</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">After dust accumulation at 85 ℓ/min, measurement is taken at 40 ℓ/min.</td>
</tr>
<tr>
<td class="header-sub">Dust Accumulation Amount</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Particles &amp; Efficiency </span><span class="bottom-left-text">Disposable / Replaceable</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" rowspan="2"><strong>Classification</strong><br />
<strong>(Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender"><strong>Test particle: Solid NaCl</strong></th>
<th class="bg-lavender"><strong>Test particle: Liquid DOP</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (≥ 80.0%)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (≥ 95.0%)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (≥ 99.9%)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (≥ 80.0%)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (≥ 95.0%)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (≥ 99.9%)</td>
</tr>
</tbody>
</table>
<h2>High Efficiency Filter + Face-Friendly Surface</h2>
<h3>2. Surface Engineering for a Better Facial Fit</h3>
<p>Even if a dust mask has a high collection efficiency filter, it is useless if dust leaks in through the facepiece seal. The primary cause of leakage is the “gap at the contact area when wearing the mask.” We consider the fit of the mask to be as important as the filter performance. Therefore, our company has developed technology to enhance the airtightness of the facial contact area.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" sizes="auto, (max-width: 247px) 100vw, 247px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg 775w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-227x300.jpg 227w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-768x1015.jpg 768w" alt="" width="247" height="326" /><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and easily adapts to body movements, ensuring wearing comfort and stability during use.</p>
<p><strong>HAWC Harness</strong><br />
The harness design ensures high tension and maximizes the “suction” effect when wearing the mask, guaranteeing an airtight seal on the face.<img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" sizes="auto, (max-width: 145px) 100vw, 145px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png 319w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014-267x300.png 267w" alt="" width="145" height="163" /></p>
<p><strong>Freeposition Underchin</strong><br />
The special shape of the facial contact area prevents dust entry. The nose section is adjustable for different sizes, ensuring a perfect fit for a wide range of facial dimensions (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" sizes="auto, (max-width: 192px) 100vw, 192px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png 410w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024-300x180.png 300w" alt="" width="192" height="115" /></p>
<p><strong data-start="56" data-end="112">Fit Status of the Freeposition Underchin Facepiece</strong><br data-start="112" data-end="115" />(Cross-sectional simulation to show the contact position between the mask and the chin).</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong data-start="56" data-end="94">For large faces:</strong><br data-start="94" data-end="97" />Uses the outer section of the mask to adjust the fit around the chin.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td width="64"><strong data-start="164" data-end="202">For small faces:</strong><br data-start="202" data-end="205" />Uses the inner section of the mask to adjust the fit around the chin.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Wearing Safety</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Internal Fit Checker</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed for various face shapes; the cushion naturally fits your face.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Utilizes a 3D poly-band harness that matches head shapes to enhance the feeling of fit and seal.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>Built-in fit checker allows for seal checks at any time (for models 1005, 1010A, 1015, 1180 series).</td>
</tr>
</tbody>
</table>
<p data-start="36" data-end="48"><strong data-start="31" data-end="55">Head Strap Types</strong><br data-start="55" data-end="58" />Please replace the head straps periodically.</p>
<p data-start="36" data-end="48"><img loading="lazy" decoding="async" class="size-medium wp-image-192603 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2-300x187.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2-300x187.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2-768x478.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2.jpg 1024w" alt="" width="300" height="187" /></p>
<h2 data-start="80" data-end="117"><strong data-start="118" data-end="143">Sakai – Model 1121R-08</strong></h2>
<p data-start="80" data-end="117">RL2 – Dual filter mask, easy to breathe</p>
<p>Type Certification: TM231<br />
Assigned Protection Factor: 10<br />
Compatible with KBC filter</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56455" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_154435-removebg-preview.png" alt="" width="270" height="226" /></p>
<ul>
<li>Under Chin Design</li>
<li>Silicone Facepiece</li>
<li>Size S available</li>
</ul>
<div class="spec-table-container">
<div class="table-title">
<table class="spec-table">
<tbody>
<tr>
<th class="col-label"><strong>Particle Collection Efficiency</strong></th>
<td class="col-value">
<div class="value-wrapper">95.0% or higher<br />
(Average 98.8%)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">64Pa or less<br />
(Average 44Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">52Pa or less<br />
(Average 29Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance Increase</strong></th>
<td class="col-value">
<div class="wrapper">―<br />
(Average 71Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-value">
<div class="value-wrapper">167g or less<br />
(Average 144g)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Head Harness</strong></th>
<td class="col-value">RB Type</td>
</tr>
</tbody>
</table>
</div>
<p>Replacement Parts: Exhalation valve: T-6K type</p>
</div>
<h2 data-start="317" data-end="367"><strong data-start="368" data-end="394">Sakai – Model 1121RX-04</strong></h2>
<p data-start="317" data-end="367">RL2 – Stable fit with 4-point head strap</p>
<p>Type Certification: TM311<br />
Assigned Protection Factor: 10<br />
Compatible with KBC filter</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56456" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_154445-removebg-preview.png" alt="" width="270" height="215" /></p>
<ul>
<li>Under Chin Design</li>
<li>Silicone Facepiece</li>
<li>Size S available</li>
</ul>
<div class="table-title">
<table class="spec-table">
<tbody>
<tr>
<th class="col-label"><strong>Particle Collection Efficiency</strong></th>
<td class="col-value">
<div class="value-wrapper">95.0% or higher<br />
(Average 99.0%)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">64Pa or less<br />
(Average 48Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">47Pa or less<br />
(Average 29Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance Increase</strong></th>
<td class="col-value">
<div class="value-wrapper">―<br />
(Average 68Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-value">
<div class="value-wrapper">172g or less<br />
(Average 150g)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Head Harness</strong></th>
<td class="col-value">XRB Type</td>
</tr>
</tbody>
</table>
</div>
<p>Replacement Parts: Exhalation valve: T-6K type</p>
<p data-start="31" data-end="77"><strong>▲ Shared Replacement Parts for 6 Models (1181R-03, 1121R-08, 1191SD-03, etc.)</strong></p>
<ul>
<li data-start="80" data-end="104">Inhalation valve: Circular type</li>
<li data-start="107" data-end="139">Moisture sponge: Oval type</li>
</ul>
<h3 data-start="141" data-end="406">Replacement Filters · Optional Accessories</h3>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong>LAS-52</strong> <em>(for 1181R)</em></td>
<td width="64"><strong>LAS-52C</strong> <em>(for 1181RC)</em></td>
<td width="64"><strong>LAS-1</strong> <em>(for 1121R, 1121RX, 1191SD, 1191D)</em></td>
<td width="64"><strong>LAS-51</strong> <em>(for 1180)</em></td>
<td width="64"><strong>LAS-51C</strong> <em>(for 1180C)</em></td>
<td width="64"><strong>KBC Filter for 1121 / 1191</strong><br data-start="68" data-end="71" /><em>(Ozone &amp; organic odor removal – pack of 5)</em><br data-start="118" data-end="121" />For: 1121R / 1121RX / 1191SD / 1191D / 1122R<br data-start="184" data-end="187" />(Optional)</td>
<td width="64"><strong>Fit Test Device – Type F</strong><br data-start="245" data-end="248" />For: 1181R, 1181RC, 1121R, 1121RX, 1191SD, 1191D<br data-start="315" data-end="318" />(Optional)</td>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56448" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152816-removebg-preview.png" alt="" width="175" height="122" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56447" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152823-removebg-preview.png" alt="" width="174" height="124" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56446" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152827-removebg-preview.png" alt="" width="176" height="136" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56445" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152834-removebg-preview.png" alt="" width="162" height="114" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56444" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152839-removebg-preview.png" alt="" width="155" height="123" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56443" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152848-removebg-preview.png" alt="" width="232" height="121" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56442" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152853-removebg-preview.png" alt="" width="254" height="139" /></td>
</tr>
<tr>
<td height="19">Screw-in connection – Pack of 2</td>
<td>Screw-in connection – Pack of 2</td>
<td>Pack of 2</td>
<td>Screw-in connection – Pack of 2</td>
<td>Screw-in connection – Pack of 2</td>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<ul>
<li data-start="69" data-end="170">Underchin: Specialized curve improves facial seal.</li>
<li data-start="174" data-end="309">Silicone: Soft, skin-friendly material provides a comfortable wearing experience. Facepiece uses a silicone seal.</li>
<li data-start="313" data-end="392">Size S available: Smaller facial dimensions are catered for with Size S.</li>
<li data-start="396" data-end="516">Low Resistance: Uses Alpha Ring filter for low breathing effort, suitable for long-duration work.</li>
<li data-start="520" data-end="637">Speaking Diaphragm: Enables clear communication and commands while wearing the mask.</li>
<li data-start="641" data-end="749">Activated Carbon: Simultaneously removes low-concentration ozone using carbon-treated filters.</li>
<li data-start="753" data-end="867">Micron Filter: High-efficiency electrostatic filter compliant with RL classification.</li>
<li data-start="871" data-end="999">Fit Checker: Simple lever mechanism to perform fit tests at any time.</li>
</ul>
<table>
<tbody>
<tr>
<td class="xl65" rowspan="2" width="64" height="38">
<p data-start="31" data-end="62"><strong>Double-Layer Bonnet Structure</strong></p>
<p data-start="64" data-end="422">The exhalation valve is shielded inside the bonnet, protecting it from external factors like wind. Exhaled air within the upper bonnet acts as a barrier, preventing direct external impact and protecting the valve. This significantly improves exhalation valve performance and stability under real usage conditions.</p>
</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56450" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447.png" sizes="auto, (max-width: 203px) 100vw, 203px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447.png 203w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-150x150.png 150w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-72x72.png 72w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-200x200.png 200w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-120x120.png 120w" alt="" width="203" height="202" /></td>
</tr>
<tr>
<td height="19"><strong>Note on Replacement</strong><br data-start="1030" data-end="1033" />Always replace consumable parts like filters early as recommended.</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/koken-1121-series-dust-mask/">Koken 1121 Series Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken 1191 Series Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-1191-series-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 14 Mar 2020 03:08:10 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192850</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: 1191 Series Important points when wearing a mask Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself from inhaling dust while wearing a mask, the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical. 1. Filter [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-1191-series-dust-mask/">Koken 1191 Series Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: 1191 Series</p>
<h2>Important points when wearing a mask</h2>
<p>Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself from inhaling dust while wearing a mask, the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Through unique technology, wool fibers are electrostatically charged, allowing electrostatic force to draw particles to the fiber surface. This is the primary mechanism for collecting particles. A high-density fiber structure is unnecessary, successfully integrating the two contrasting features: &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221; It consistently maintains the highest standard of performance and quality, making it an excellent long-term filter solution.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" sizes="auto, (max-width: 317px) 100vw, 317px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png 317w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333-300x204.png 300w" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" sizes="auto, (max-width: 316px) 100vw, 316px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png 316w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322-300x227.png 300w" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applied products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the fiber density of the filter enhances collection efficiency. To meet airflow resistance standards, paper filters traditionally require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into pristine circular shapes in a single process, creating the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" sizes="auto, (max-width: 329px) 100vw, 329px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751-300x116.png 300w" alt="" width="329" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" sizes="auto, (max-width: 321px) 100vw, 321px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png 321w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803-300x227.png 300w" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applied products are from page P.8 to P.11</p>
<p data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td width="64">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the “Dust Respirator Standards”.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct-Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Particles</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ /min</td>
<td class="text-center" colspan="2">85 ℓ /min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement; must meet values in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" colspan="2">For NaCl particles<br />
Load up to 100mg</td>
<td class="text-left" colspan="2">For DOP particles<br />
Load up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or higher</td>
<td>RL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or higher</td>
<td>RL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or higher</td>
<td>RL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or higher</td>
<td>DL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or higher</td>
<td>DL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or higher</td>
<td>DL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>( ) indicates products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col">Exhalation valve leak test</td>
<td>– Internal pressure must drop immediately during suction.<br />
– Time for internal pressure to return to normal must be 15 seconds or more.</td>
</tr>
<tr>
<th class="header-col"><strong>CO2 Concentration Increase</strong></th>
<td class="content-col" colspan="2">Measured using a test headform and artificial lung. The difference in CO2 concentration in inhaled air with and without the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space</strong></th>
<td class="content-col" colspan="2">Value calculated from the CO2 Concentration Increase Test.</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Particles</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">After dust accumulation at 85 ℓ/min, measurement is taken at 40 ℓ/min.</td>
</tr>
<tr>
<td class="header-sub">Dust Accumulation Amount</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Particles &amp; Efficiency </span><span class="bottom-left-text">Disposable / Replaceable</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" rowspan="2"><strong>Classification</strong><br />
<strong>(Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender"><strong>Test particle: Solid NaCl</strong></th>
<th class="bg-lavender"><strong>Test particle: Liquid DOP</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (≥ 80.0%)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (≥ 95.0%)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (≥ 99.9%)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (≥ 80.0%)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (≥ 95.0%)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (≥ 99.9%)</td>
</tr>
</tbody>
</table>
<h2>High Efficiency Filter + Face-Friendly Surface</h2>
<h3>2. Surface Engineering for a Better Facial Fit</h3>
<p>Even if a dust mask has a high collection efficiency filter, it is useless if dust leaks in through the facepiece seal. The primary cause of leakage is the “gap at the contact area when wearing the mask.” We consider the fit of the mask to be as important as the filter performance. Therefore, our company has developed technology to enhance the airtightness of the facial contact area.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" sizes="auto, (max-width: 247px) 100vw, 247px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg 775w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-227x300.jpg 227w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-768x1015.jpg 768w" alt="" width="247" height="326" /><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and easily adapts to body movements, ensuring wearing comfort and stability during use.</p>
<p><strong>HAWC Harness</strong><br />
The harness design ensures high tension and maximizes the “suction” effect when wearing the mask, guaranteeing an airtight seal on the face.<img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" sizes="auto, (max-width: 145px) 100vw, 145px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png 319w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014-267x300.png 267w" alt="" width="145" height="163" /></p>
<p><strong>Freeposition Underchin</strong><br />
The special shape of the facial contact area prevents dust entry. The nose section is adjustable for different sizes, ensuring a perfect fit for a wide range of facial dimensions (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" sizes="auto, (max-width: 192px) 100vw, 192px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png 410w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024-300x180.png 300w" alt="" width="192" height="115" /></p>
<p><strong data-start="56" data-end="112">Fit Status of the Freeposition Underchin Facepiece</strong><br data-start="112" data-end="115" />(Cross-sectional simulation to show the contact position between the mask and the chin).</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong data-start="56" data-end="94">For large faces:</strong><br data-start="94" data-end="97" />Uses the outer section of the mask to adjust the fit around the chin.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td width="64"><strong data-start="164" data-end="202">For small faces:</strong><br data-start="202" data-end="205" />Uses the inner section of the mask to adjust the fit around the chin.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Wearing Safety</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Internal Fit Checker</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed for various face shapes; the cushion naturally fits your face.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Utilizes a 3D poly-band harness that matches head shapes to enhance the feeling of fit and seal.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>Fit checker is integrated inside, helping to check the mask seal at any time (for 1005, 1010A, 1015, 1180 series).</td>
</tr>
</tbody>
</table>
<p data-start="36" data-end="48"><strong data-start="31" data-end="55">Head Strap Types</strong><br data-start="55" data-end="58" />Please replace the head straps periodically.</p>
<p data-start="36" data-end="48"><img loading="lazy" decoding="async" class="size-medium wp-image-192603 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2-300x187.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2-300x187.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2-768x478.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2.jpg 1024w" alt="" width="300" height="187" /></p>
<h2 data-start="559" data-end="596"><strong>Sakaki – Model 1191SD-03</strong></h2>
<p data-start="559" data-end="596">RL2 Classification – Easy to wear with RB-style harness</p>
<p data-start="628" data-end="661">Model Assay Certificate: TM318<br />
Assigned Protection Factor: 10<br />
Compatible with KBC filters</p>
<p data-start="628" data-end="661"><img loading="lazy" decoding="async" class="aligncenter wp-image-56459" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_155416-removebg-preview.png" alt="" width="276" height="226" /></p>
<ul>
<li data-start="698" data-end="726">Undercut Seal</li>
<li data-start="698" data-end="726">Silicone Facepiece</li>
<li data-start="698" data-end="726">Speaking Diaphragm</li>
</ul>
<div class="spec-table-container">
<table class="spec-table">
<tbody>
<tr>
<th class="col-label"><strong>Particle Collection Efficiency</strong></th>
<td class="col-value">
<div class="value-wrapper">95.0% or higher<br />
(Average 99.1%)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">64Pa or less<br />
(Average 48Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">33Pa or less<br />
(Average 20Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance Increase</strong></th>
<td class="col-value">
<div class="value-wrapper">―<br />
(Average 77Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-value">
<div class="value-wrapper">185g or less<br />
(Average 166g)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Harness</strong></th>
<td class="col-value">RB Type</td>
</tr>
</tbody>
</table>
</div>
<div class="spec-table-container">Replacement Parts: Exhalation valve – T-1 type</div>
<h2 data-start="791" data-end="862"><strong>Sakaki – Model 1191D-03</strong></h2>
<p data-start="791" data-end="862">RL2 Classification – Equipped with speaking diaphragm for easy communication and commands</p>
<p data-start="893" data-end="926">Model Assay Certificate: TM232<br />
Assigned Protection Factor: 10<br />
Compatible with KBC filters</p>
<p data-start="893" data-end="926"><img loading="lazy" decoding="async" class="aligncenter wp-image-56460" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_155406-removebg-preview.png" alt="" width="275" height="212" /></p>
<ul>
<li data-start="994" data-end="1049">Undercut Seal</li>
<li data-start="994" data-end="1049">Silicone Facepiece</li>
<li data-start="994" data-end="1049">Speaking Diaphragm</li>
</ul>
<div class="table-title">
<table class="spec-table">
<tbody>
<tr>
<th class="col-label"><strong>Particle Collection Efficiency</strong></th>
<td class="col-value">
<div class="value-wrapper">95.0% or higher<br />
(Average 98.9%)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">64Pa or less<br />
(Average 47Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">35Pa or less<br />
(Average 18Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance Increase</strong></th>
<td class="col-value">
<div class="value-wrapper">―<br />
(Average 73Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-value">
<div class="value-wrapper">188g or less<br />
(Average 168g)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Harness</strong></th>
<td class="col-value">XRB Type</td>
</tr>
</tbody>
</table>
</div>
<p>Replacement Parts: Exhalation valve – T-1 type</p>
<p data-start="31" data-end="77"><strong>▲ Common Replacement Parts for 6 Models (1181R-03, 1121R-08, 1191SD-03, etc.)</strong></p>
<ul>
<li data-start="80" data-end="104">Inhalation valve: circular type</li>
<li data-start="107" data-end="139">Moisture sponge: oval type</li>
</ul>
<h3 data-start="141" data-end="406">Replacement Filters · Optional Accessories</h3>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong>LAS-52</strong> <em>(for 1181R)</em></td>
<td width="64"><strong>LAS-52C</strong> <em>(for 1181RC)</em></td>
<td width="64"><strong>LAS-1</strong> <em>(for 1121R, 1121RX, 1191SD, 1191D)</em></td>
<td width="64"><strong>LAS-51</strong> <em>(for 1180)</em></td>
<td width="64"><strong>LAS-51C</strong> <em>(for 1180C)</em></td>
<td width="64"><strong>KBC Filter for 1121 / 1191</strong><br data-start="68" data-end="71" /><em>(Ozone &amp; organic odor removal – pack of 5)</em><br data-start="118" data-end="121" />For models: 1121R / 1121RX / 1191SD / 1191D / 1122R<br data-start="184" data-end="187" />(Optional)</td>
<td width="64"><strong>Fit Checker – Type F</strong><br data-start="245" data-end="248" />For models: 1181R, 1181RC, 1121R, 1121RX, 1191SD, 1191D<br data-start="315" data-end="318" />(Optional)</td>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56448" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152816-removebg-preview.png" alt="" width="175" height="122" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56447" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152823-removebg-preview.png" alt="" width="174" height="124" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56446" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152827-removebg-preview.png" alt="" width="176" height="136" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56445" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152834-removebg-preview.png" alt="" width="162" height="114" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56444" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152839-removebg-preview.png" alt="" width="155" height="123" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56443" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152848-removebg-preview.png" alt="" width="232" height="121" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56442" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152853-removebg-preview.png" alt="" width="254" height="139" /></td>
</tr>
<tr>
<td height="19">Screw-in – pack of 2</td>
<td>Screw-in – pack of 2</td>
<td>Pack of 2</td>
<td>Screw-in – pack of 2</td>
<td>Screw-in – pack of 2</td>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<ul>
<li data-start="69" data-end="170">Under Chin: Enhanced facial seal thanks to the specialized ergonomic curve.</li>
<li data-start="174" data-end="309">Silicone: Soft, skin-friendly material for a comfortable wearing experience.</li>
<li data-start="313" data-end="392">Small Size Available: Option for users with smaller facial dimensions.</li>
<li data-start="396" data-end="516">Low Inhalation Resistance: Employs Alpha Ring filter technology for reduced breathing effort.</li>
<li data-start="520" data-end="637">Speaking Diaphragm: Allows for verbal communication and commands while wearing the mask.</li>
<li data-start="641" data-end="749">Activated Carbon: Simultaneously removes low concentrations of ozone.</li>
<li data-start="753" data-end="867">Micron: High-efficiency electrostatic filter material compliant with RL classification.</li>
<li data-start="871" data-end="999">Fit Checker: Simple lever mechanism to perform fit tests at any time.</li>
</ul>
<table>
<tbody>
<tr>
<td class="xl65" rowspan="2" width="64" height="38">
<p data-start="31" data-end="62"><strong>Double-Layer Bonnet Structure</strong></p>
<p data-start="64" data-end="422">The exhalation valve is shielded within the bonnet, protecting it from external elements like wind. Exhaled air within the upper bonnet acts as a barrier, improving valve stability and performance during active site use.</p>
</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56450" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447.png" sizes="auto, (max-width: 203px) 100vw, 203px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447.png 203w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-150x150.png 150w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-72x72.png 72w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-200x200.png 200w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-120x120.png 120w" alt="" width="203" height="202" /></td>
</tr>
<tr>
<td height="19"><strong>Note on Replacement</strong><br data-start="1030" data-end="1033" />Consumable parts such as filters should be replaced promptly as recommended.</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/koken-1191-series-dust-mask/">Koken 1191 Series Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken 1180 Series Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-1180-series-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 14 Mar 2020 03:05:05 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192848</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: 1180 Series Important points when wearing a mask Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself while wearing a dust mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical. 1. Filter Technology [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-1180-series-dust-mask/">Koken 1180 Series Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: 1180 Series</p>
<h2>Important points when wearing a mask</h2>
<p>Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself while wearing a dust mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Using unique technology, wool fibers are electrostatically charged, allowing electrostatic force to draw particles to the fiber surface. This is the primary mechanism for capturing particles. A high-density fiber structure is unnecessary, successfully integrating the two contrasting features: &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221; It consistently maintains the highest standard of performance and quality, making it an excellent long-term filter solution.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" sizes="auto, (max-width: 317px) 100vw, 317px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png 317w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333-300x204.png 300w" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" sizes="auto, (max-width: 316px) 100vw, 316px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png 316w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322-300x227.png 300w" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applied products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the fiber density of the filter enhances collection efficiency. To meet airflow resistance standards, paper filters traditionally require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into pristine circular shapes in a single process, creating the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" sizes="auto, (max-width: 329px) 100vw, 329px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751-300x116.png 300w" alt="" width="329" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" sizes="auto, (max-width: 321px) 100vw, 321px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png 321w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803-300x227.png 300w" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applied products are from page P.8 to P.11</p>
<p data-start="46" data-end="81"><strong>Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong>Dust Respirator Standards</strong></th>
<td width="64">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the “Dust Respirator Standards”.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct-Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Particles</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ/min</td>
<td class="text-center" colspan="2">85 ℓ/min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement; must meet values in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" colspan="2">For NaCl particles<br />
Load up to 100mg</td>
<td class="text-left" colspan="2">For DOP particles<br />
Load up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or higher</td>
<td>RL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or higher</td>
<td>RL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or higher</td>
<td>RL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or higher</td>
<td>DL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or higher</td>
<td>DL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or higher</td>
<td>DL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test Flow Rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test Flow Rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>Values in ( ) are for products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col">Exhalation valve leak test</td>
<td>– Internal pressure must drop immediately during suction.<br />
– Time for internal pressure to return to normal must be 15 seconds or more.</td>
</tr>
<tr>
<th class="header-col"><strong>CO2 Concentration Increase</strong></th>
<td class="content-col" colspan="2">Measured using a test headform and artificial lung. The difference in CO2 concentration in inhaled air with and without the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space</strong></th>
<td class="content-col" colspan="2">Value calculated from the CO2 Concentration Increase Test.</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Particles</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">After dust accumulation at 85 ℓ/min, measurement is taken at 40 ℓ/min.</td>
</tr>
<tr>
<td class="header-sub">Dust Accumulation Amount</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Particles &amp; Efficiency </span><span class="bottom-left-text">Disposable / Replaceable</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" rowspan="2"><strong>Classification</strong><br />
<strong>(Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender"><strong>Test particle: Solid NaCl</strong></th>
<th class="bg-lavender"><strong>Test particle: Liquid DOP</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (≥ 80.0%)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (≥ 95.0%)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (≥ 99.9%)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (≥ 80.0%)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (≥ 95.0%)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (≥ 99.9%)</td>
</tr>
</tbody>
</table>
<h2>High Efficiency Filter + Face-Friendly Surface</h2>
<h3>2. Surface Engineering for a Better Facial Fit</h3>
<p>Even if a dust mask has a high collection efficiency filter, it is useless if dust leaks in through the facepiece seal. The primary cause of leakage is the “gap at the contact area when wearing the mask.” We consider the fit of the mask to be as important as the filter performance. Therefore, our company has developed technology to enhance the airtightness of the facial contact area.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" sizes="auto, (max-width: 247px) 100vw, 247px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg 775w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-227x300.jpg 227w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-768x1015.jpg 768w" alt="" width="247" height="326" /></p>
<p><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and easily adapts to body movements, ensuring wearing comfort and stability during use.</p>
<p><strong>HAWC Harness</strong><br />
The harness design ensures high tension and maximizes the “suction” effect when wearing the mask, guaranteeing an airtight seal on the face.<img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" sizes="auto, (max-width: 145px) 100vw, 145px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png 319w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014-267x300.png 267w" alt="" width="145" height="163" /></p>
<p><strong>Freeposition Under-Chin</strong><br />
The special shape of the facial contact area prevents dust entry. The nose section is adjustable for different sizes, ensuring a perfect fit for a wide range of facial dimensions (see image below).<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" sizes="auto, (max-width: 192px) 100vw, 192px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png 410w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024-300x180.png 300w" alt="" width="192" height="115" /></p>
<p><strong>Fit Status of the Freeposition Under-Chin Facepiece</strong><br data-start="112" data-end="115" />(Cross-sectional simulation to show the contact position between the mask and the chin).</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong>For large faces:</strong><br data-start="94" data-end="97" />Uses the outer section of the mask to adjust the fit around the chin.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td width="64"><strong>For small faces:</strong><br data-start="202" data-end="205" />Uses the inner section of the mask to adjust the fit around the chin.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Wearing Safety</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Internal Fit Checker</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed for various face shapes; the cushion naturally fits your face.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Utilizes a 3D poly-band harness that matches head shapes to enhance the feeling of fit and seal.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>Built-in fit checker allows for seal checks at any time (for models 1005, 1010A, 1015, 1180 series).</td>
</tr>
</tbody>
</table>
<p data-start="36" data-end="48"><strong>Harness Types</strong><br data-start="55" data-end="58" />Please replace the harness regularly.</p>
<p data-start="36" data-end="48"><img loading="lazy" decoding="async" class="size-medium wp-image-192603 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2-300x187.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2-300x187.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2-768x478.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2.jpg 1024w" alt="" width="300" height="187" /></p>
<h2>Sakaki – Model 1180-05</h2>
<p data-start="80" data-end="133">Double-layer bonnet structure protecting the exhalation valve.</p>
<p data-start="134" data-end="227">RL2 Classification<br />
Built-in Fit Checker<br data-start="180" data-end="183" />Compact, lightweight model – 99 g<br data-start="206" data-end="209" />Size S available</p>
<p data-start="260" data-end="303">Model Assay Certificate: TM538<br />
Assigned Protection Factor: 10</p>
<p data-start="337" data-end="419">Can be used as a gas mask (G-7 configuration)<br data-start="385" data-end="388" />(Absorbent canisters sold separately)</p>
<p data-start="422" data-end="463">Gas Mask Certificate: TN382</p>
<p data-start="422" data-end="463"><img loading="lazy" decoding="async" class="aligncenter wp-image-56463" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_161359-removebg-preview.png" alt="" width="200" height="227" /></p>
<p data-start="465" data-end="480">Option: Moisture Sponge Type A</p>
<ul>
<li data-start="912" data-end="950">Fit Checker (rapid seal test)</li>
<li data-start="953" data-end="975">Under-Chin cushion</li>
<li data-start="978" data-end="994">Silicone facepiece</li>
<li data-start="997" data-end="1006">Size S available</li>
</ul>
<div class="spec-table-container">
<table class="spec-table">
<tbody>
<tr>
<th class="col-label"><strong>Particle Collection Efficiency</strong></th>
<td class="col-value">
<div class="value-wrapper">95.0% or higher<br />
(Average 98.0%)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">80Pa or less<br />
(Average 72Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">45Pa or less<br />
(Average 25Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance Increase</strong></th>
<td class="col-value">
<div class="value-wrapper">―<br />
(Average 123Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-value">
<div class="value-wrapper">114g or less<br />
(Average 99g)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Harness</strong></th>
<td class="col-value">RB Type</td>
</tr>
</tbody>
</table>
<p data-start="504" data-end="528">Consumable Parts:</p>
<ul>
<li data-start="531" data-end="557">Inhalation valve: Small 03 type</li>
<li data-start="560" data-end="580">Exhalation valve: T-7 type</li>
</ul>
<h2>Sakaki – Model 1180C-05</h2>
<p data-start="587" data-end="626">Equipped with Activated Carbon Filter</p>
<p data-start="627" data-end="722">RL2 Classification<br />
Suitable for organic odors and ozone below permissible levels<br data-start="687" data-end="690" />Built-in Fit Checker</p>
<p data-start="724" data-end="772"><strong>Warning:</strong> Not a dedicated gas mask for high concentrations.</p>
<p data-start="806" data-end="849">Model Assay Certificate: TM539<br />
Assigned Protection Factor: 10</p>
<p data-start="806" data-end="849"><img loading="lazy" decoding="async" class="wp-image-56464 aligncenter" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_161841-removebg-preview.png" alt="" width="200" height="218" /></p>
<p data-start="806" data-end="849">Option: Moisture Sponge Type A</p>
<ul data-start="804" data-end="881">
<li data-start="912" data-end="950">Fit Checker (rapid seal test)</li>
<li data-start="953" data-end="975">Under-Chin cushion</li>
<li data-start="978" data-end="994">Silicone facepiece</li>
<li data-start="997" data-end="1006">Size S available</li>
<li data-start="1009" data-end="1030">Low inhalation resistance</li>
<li data-start="1033" data-end="1054">Activated carbon filter</li>
</ul>
<div class="spec-table-container">
<table class="spec-table">
<tbody>
<tr>
<th class="col-label"><strong>Particle Collection Efficiency</strong></th>
<td class="col-value">
<div class="value-wrapper">95.0% or higher<br />
(Average 98.8%)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">80Pa or less<br />
(Average 71Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">45Pa or less<br />
(Average 27Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance Increase</strong></th>
<td class="col-value">
<div class="value-wrapper">―<br />
(Average 133Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-value">
<div class="value-wrapper">113g or less<br />
(Average 98g)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Harness</strong></th>
<td class="col-value">RB Type</td>
</tr>
</tbody>
</table>
</div>
<p data-start="1095" data-end="1119">Consumable Parts:</p>
<ul>
<li data-start="1122" data-end="1148">Inhalation valve: Small 03 type</li>
<li data-start="1151" data-end="1171">Exhalation valve: T-7 type</li>
</ul>
<p><strong>▲ Shared Replacement Parts for 6 Models (1181R-03, 1121R-08, 1191SD-03, etc.)</strong></p>
<ul>
<li data-start="80" data-end="104">Inhalation valve: circular type</li>
<li data-start="107" data-end="139">Moisture sponge: oval type</li>
</ul>
<h3>Replacement Filters · Optional Accessories</h3>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong>LAS-52</strong> <em>(for 1181R)</em></td>
<td width="64"><strong>LAS-52C</strong> <em>(for 1181RC)</em></td>
<td width="64"><strong>LAS-1</strong> <em>(for 1121R, 1121RX, 1191SD, 1191D)</em></td>
<td width="64"><strong>LAS-51</strong> <em>(for 1180)</em></td>
<td width="64"><strong>LAS-51C</strong> <em>(for 1180C)</em></td>
<td width="64"><strong>KBC Filter for 1121 / 1191</strong><br data-start="68" data-end="71" /><em>(Ozone &amp; organic odor removal – pack of 5)</em><br data-start="118" data-end="121" />For: 1121R / 1121RX / 1191SD / 1191D / 1122R<br data-start="184" data-end="187" />(Optional)</td>
<td width="64"><strong>Fit Test Device – Type F</strong><br data-start="245" data-end="248" />For: 1181R, 1181RC, 1121R, 1121RX, 1191SD, 1191D<br data-start="315" data-end="318" />(Optional)</td>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56448" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152816-removebg-preview.png" alt="" width="175" height="122" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56447" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152823-removebg-preview.png" alt="" width="174" height="124" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56446" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152827-removebg-preview.png" alt="" width="176" height="136" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56445" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152834-removebg-preview.png" alt="" width="162" height="114" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56444" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152839-removebg-preview.png" alt="" width="155" height="123" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56443" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152848-removebg-preview.png" alt="" width="232" height="121" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56442" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152853-removebg-preview.png" alt="" width="254" height="139" /></td>
</tr>
<tr>
<td height="19">Screw-in – Pack of 2</td>
<td>Screw-in – Pack of 2</td>
<td>Pack of 2</td>
<td>Screw-in – Pack of 2</td>
<td>Screw-in – Pack of 2</td>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<ul>
<li data-start="69" data-end="170">Under Chin: Specialized curve enhances seal at facial contact points.</li>
<li data-start="174" data-end="309">Silicone: Soft, skin-friendly material provides a comfortable wearing feel. Facepiece seal uses silicone.</li>
<li data-start="313" data-end="392">Size S Available: Small size option for users with petite faces.</li>
<li data-start="396" data-end="516">Low Resistance: Uses Alpha Ring filter for low breathing resistance, allowing for long-duration work.</li>
<li data-start="520" data-end="637">Speaking Diaphragm: Allows communication and instructions to be heard without removing the mask.</li>
<li data-start="641" data-end="749">Activated Carbon: Effectively removes low-concentration ozone using carbon-treated filters.</li>
<li data-start="753" data-end="867">Micron: High-performance electrostatic filter compliant with RL classification.</li>
<li data-start="871" data-end="999">Fit Checker: Perform a manual seal test by simply operating the lever.</li>
</ul>
<table>
<tbody>
<tr>
<td class="xl65" rowspan="2" width="64" height="38">
<p data-start="31" data-end="62"><strong>Double-Layer Bonnet Structure</strong></p>
<p data-start="64" data-end="422">The exhalation valve is shielded inside the bonnet from external factors like wind. Exhaled air accumulated in the upper bonnet acts as a buffer (barrier), preventing direct external impact and protecting the valve. This significantly improves exhalation valve performance and stability under real usage conditions.</p>
</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56450" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447.png" sizes="auto, (max-width: 203px) 100vw, 203px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447.png 203w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-150x150.png 150w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-72x72.png 72w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-200x200.png 200w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-120x120.png 120w" alt="" width="203" height="202" /></td>
</tr>
<tr>
<td height="19"><strong>Note on Replacement</strong><br data-start="1030" data-end="1033" />Always replace filters and consumable parts according to recommended schedules.</td>
</tr>
</tbody>
</table>
</div>The post <a href="https://koueitrading.com/global/product/koken-1180-series-dust-mask/">Koken 1180 Series Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken 1122R-03 Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-1122r-03-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Sat, 14 Mar 2020 02:17:18 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192838</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: 1122R-03 Important points when wearing a mask Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself while wearing a dust mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical. 1. Filter Technology with [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-1122r-03-dust-mask/">Koken 1122R-03 Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: 1122R-03</p>
<h2>Important points when wearing a mask</h2>
<p>Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself while wearing a dust mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Using unique technology, wool fibers are electrostatically charged, allowing electrostatic force to draw particles to the fiber surface. This is the primary mechanism for capturing particles. A high-density fiber structure is unnecessary, successfully integrating the two contrasting features: &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221; It consistently maintains the highest standard of performance and quality, making it an excellent long-term filter solution.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" sizes="auto, (max-width: 317px) 100vw, 317px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png 317w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333-300x204.png 300w" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" sizes="auto, (max-width: 316px) 100vw, 316px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png 316w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322-300x227.png 300w" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applied products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the fiber density of the filter enhances collection efficiency. To meet airflow resistance standards, paper filters traditionally require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into pristine circular shapes in a single process, creating the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" sizes="auto, (max-width: 329px) 100vw, 329px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751-300x116.png 300w" alt="" width="329" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" sizes="auto, (max-width: 321px) 100vw, 321px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png 321w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803-300x227.png 300w" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applied products are from page P.8 to P.11</p>
<p data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td width="64">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the “Dust Respirator Standards”.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct-Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Particles</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ /min</td>
<td class="text-center" colspan="2">85 ℓ /min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement; must meet values in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" colspan="2">For NaCl particles<br />
Load up to 100mg</td>
<td class="text-left" colspan="2">For DOP particles<br />
Load up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or higher</td>
<td>RL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or higher</td>
<td>RL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or higher</td>
<td>RL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or higher</td>
<td>DL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or higher</td>
<td>DL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or higher</td>
<td>DL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>Values in ( ) are for products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col">Exhalation valve leak test</td>
<td>– Internal pressure must drop immediately during suction.<br />
– Time for internal pressure to return to normal must be 15 seconds or more.</td>
</tr>
<tr>
<th class="header-col"><strong>CO2 Concentration Increase</strong></th>
<td class="content-col" colspan="2">Measured using a test headform and artificial lung. The difference in CO2 concentration in inhaled air with and without the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space</strong></th>
<td class="content-col" colspan="2">Value calculated from the CO2 Concentration Increase Test.</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Particles</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">After dust accumulation at 85 ℓ/min, measurement is taken at 40 ℓ/min.</td>
</tr>
<tr>
<td class="header-sub">Dust Accumulation Amount</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Particles &amp; Efficiency </span><span class="bottom-left-text">Disposable / Replaceable</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" rowspan="2"><strong>Classification</strong><br />
<strong>(Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender"><strong>Test particle: Solid NaCl</strong></th>
<th class="bg-lavender"><strong>Test particle: Liquid DOP</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (≥ 80.0%)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (≥ 95.0%)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (≥ 99.9%)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (≥ 80.0%)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (≥ 95.0%)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (≥ 99.9%)</td>
</tr>
</tbody>
</table>
<h2>High Efficiency Filter + Face-Friendly Surface</h2>
<h3>2. Surface Engineering for a Better Facial Fit</h3>
<p>Even if a dust mask has a high collection efficiency filter, it is useless if dust leaks in through the facepiece seal. The primary cause of leakage is the “gap at the contact area when wearing the mask.” We consider the fit of the mask to be as important as the filter performance. Therefore, our company has developed technology to enhance the airtightness of the facial contact area.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" sizes="auto, (max-width: 247px) 100vw, 247px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg 775w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-227x300.jpg 227w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-768x1015.jpg 768w" alt="" width="247" height="326" /><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and easily adapts to body movements, ensuring wearing comfort and stability during use.</p>
<p><strong>HAWC Harness</strong><br />
The harness design ensures high tension and maximizes the “suction” effect when wearing the mask, guaranteeing an airtight seal on the face.<img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" sizes="auto, (max-width: 145px) 100vw, 145px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png 319w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014-267x300.png 267w" alt="" width="145" height="163" /></p>
<p><strong>Freeposition Underchin</strong><br />
The special shape of the facial contact area prevents dust entry. The nose section is adjustable for different sizes, ensuring a perfect fit for a wide range of facial dimensions (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" sizes="auto, (max-width: 192px) 100vw, 192px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png 410w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024-300x180.png 300w" alt="" width="192" height="115" /></p>
<p><strong data-start="56" data-end="112">Fit Status of the Freeposition Underchin Facepiece</strong><br data-start="112" data-end="115" />(Cross-sectional simulation to show the contact position between the mask and the chin).</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong>For large faces:</strong><br data-start="94" data-end="97" />Uses the outer section of the mask to adjust the fit around the chin.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td width="64"><strong>For small faces:</strong><br data-start="202" data-end="205" />Uses the inner section of the mask to adjust the fit around the chin.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Wearing Safety</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Internal Fit Checker</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed for various face shapes; the cushion naturally fits your face.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Utilizes a 3D poly-band harness that matches head shapes to enhance the feeling of fit and seal.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>Built-in fit checker allows for seal checks at any time (for models 1005, 1010A, 1015, 1180 series).</td>
</tr>
</tbody>
</table>
<p data-start="36" data-end="48"><strong>Harness Types</strong><br data-start="55" data-end="58" />Please replace the harness regularly.</p>
<p data-start="36" data-end="48"><img loading="lazy" decoding="async" class="size-medium wp-image-192603 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2-300x187.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2-300x187.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2-768x478.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2.jpg 1024w" alt="" width="300" height="187" /></p>
<h2>Sakai – Model 1122R-03</h2>
<p data-start="69" data-end="152">Dust and Toxic Gas Mask – Dual-protection line for enhanced air filtration efficiency</p>
<p>Model Assay Certificate: TM209<br />
Assigned Protection Factor: 10<br />
Compatible with KBC filters</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56468" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-14_102146-removebg-preview.png" alt="" width="314" height="245" /></p>
<ul>
<li>Under-chin seal: Soft silicone facepiece</li>
<li>Size S available for small faces</li>
<li>Low respiratory resistance for improved filtration efficiency</li>
</ul>
<p data-start="470" data-end="501">Compatible with LAS-12 filters<br />
Optional: Type F Fit Tester</p>
<table class="spec-table">
<tbody>
<tr>
<th class="col-label"><strong>Particle Collection Efficiency</strong></th>
<td class="col-value">
<div class="value-wrapper">95.0% or higher<br />
(Average 98.8%)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">55Pa or less<br />
(Average 37Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">52Pa or less<br />
(Average 31Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance Increase</strong></th>
<td class="col-value">
<div class="value-wrapper">―<br />
(Average 45Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-value">
<div class="value-wrapper">170g or less<br />
(Average 145g)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Harness</strong></th>
<td class="col-value">RB Type</td>
</tr>
</tbody>
</table>
<p data-start="50" data-end="72">Replacement Parts:</p>
<ul>
<li data-start="75" data-end="100">Circular Inhalation Valve</li>
<li data-start="103" data-end="129">Exhalation Valve (T-6K)</li>
<li data-start="132" data-end="155">Egg-shaped Moisture Sponge</li>
</ul>
<p data-start="31" data-end="77"><strong>▲ Shared Replacement Parts for 6 Models (1181R-03, 1121R-08, 1191SD-03, etc.)</strong></p>
<ul>
<li data-start="80" data-end="104">Inhalation valve: circular type</li>
<li data-start="107" data-end="139">Moisture sponge: oval type</li>
</ul>
<h3>Replacement Filters · Accessories (Optional)</h3>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong>LAS-52</strong> <em>(for 1181R)</em></td>
<td width="64"><strong>LAS-52C</strong> <em>(for 1181RC)</em></td>
<td width="64"><strong>LAS-1</strong> <em>(for 1121R, 1121RX, 1191SD, 1191D)</em></td>
<td width="64"><strong>LAS-51</strong> <em>(for 1180)</em></td>
<td width="64"><strong>LAS-51C</strong> <em>(for 1180C)</em></td>
<td width="64"><strong>KBC Filter for 1121 / 1191</strong><br data-start="68" data-end="71" /><em>(Ozone &amp; organic odor removal – pack of 5)</em><br data-start="118" data-end="121" />For: 1121R / 1121RX / 1191SD / 1191D / 1122R<br data-start="184" data-end="187" />(Optional)</td>
<td width="64"><strong>Type F Fit Tester</strong><br data-start="245" data-end="248" />For: 1181R, 1181RC, 1121R, 1121RX, 1191SD, 1191D<br data-start="315" data-end="318" />(Optional)</td>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56448" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152816-removebg-preview.png" alt="" width="175" height="122" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56447" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152823-removebg-preview.png" alt="" width="174" height="124" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56446" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152827-removebg-preview.png" alt="" width="176" height="136" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56445" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152834-removebg-preview.png" alt="" width="162" height="114" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56444" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152839-removebg-preview.png" alt="" width="155" height="123" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56443" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152848-removebg-preview.png" alt="" width="232" height="121" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56442" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152853-removebg-preview.png" alt="" width="254" height="139" /></td>
</tr>
<tr>
<td height="19">Screw-in – Pack of 2</td>
<td>Screw-in – Pack of 2</td>
<td>Pack of 2</td>
<td>Screw-in – Pack of 2</td>
<td>Screw-in – Pack of 2</td>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<ul>
<li data-start="69" data-end="170">Under Chin: Specialized curve enhances seal at facial contact points.</li>
<li data-start="174" data-node-end="309">Silicone: Soft, skin-friendly material provides a comfortable wearing feel. Facepiece seal uses silicone.</li>
<li data-start="313" data-end="392">Size S Available: Small size option for users with petite faces.</li>
<li data-start="396" data-end="516">Low Resistance: Uses Alpha Ring filter for low breathing resistance, allowing for long-duration work.</li>
<li data-start="520" data-end="637">Speaking Diaphragm: Allows conversation and instructions to be heard without removing the mask.</li>
<li data-start="641" data-end="749">Activated Carbon: Effectively removes low-concentration ozone using carbon-treated filters.</li>
<li data-start="753" data-end="867">Micron: High-performance electrostatic filter compliant with RL classification.</li>
<li data-start="871" data-end="999">Fit Checker: Perform a manual seal test by simply operating the lever.</li>
</ul>
<table>
<tbody>
<tr>
<td class="xl65" rowspan="2" width="64" height="38">
<p data-start="31" data-end="62"><strong>Double-Layer Bonnet Structure</strong></p>
<p data-start="64" data-end="422">The exhalation valve is shielded inside the bonnet from external factors like wind. Exhaled air accumulated in the upper bonnet acts as a buffer (barrier), preventing direct external impact and protecting the valve. This significantly improves exhalation valve performance and stability under real usage conditions.</p>
</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56450" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447.png" sizes="auto, (max-width: 203px) 100vw, 203px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447.png 203w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-150x150.png 150w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-72x72.png 72w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-200x200.png 200w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-120x120.png 120w" alt="" width="203" height="202" /></td>
</tr>
<tr>
<td height="19"><strong>Note on Replacement</strong><br data-start="1030" data-end="1033" />Always replace filters and consumable parts according to recommended schedules.</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/koken-1122r-03-dust-mask/">Koken 1122R-03 Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken 1111-03 Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-1111-03-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 12 Mar 2020 06:54:15 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192601</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: 1111-03 Important points when wearing a mask Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself while wearing a dust mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical. 1. Filter Technology with [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-1111-03-dust-mask/">Koken 1111-03 Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: 1111-03</p>
<h2>Important points when wearing a mask</h2>
<p>Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself while wearing a dust mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are critical.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Using unique technology, wool fibers are electrostatically charged, allowing electrostatic force to draw particles to the fiber surface. This is the primary mechanism for capturing particles. A high-density fiber structure is unnecessary, successfully integrating the two contrasting features: &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221; It consistently maintains the highest standard of performance and quality, making it an excellent long-term filter solution.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" sizes="auto, (max-width: 317px) 100vw, 317px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png 317w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333-300x204.png 300w" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" sizes="auto, (max-width: 316px) 100vw, 316px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png 316w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322-300x227.png 300w" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applied products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the fiber density of the filter enhances collection efficiency. To meet airflow resistance standards, paper filters traditionally require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into pristine circular shapes in a single process, creating the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" sizes="auto, (max-width: 329px) 100vw, 329px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751-300x116.png 300w" alt="" width="329" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" sizes="auto, (max-width: 321px) 100vw, 321px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png 321w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803-300x227.png 300w" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applied products are from page P.8 to P.11</p>
<p data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td width="64">In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the “Dust Respirator Standards”.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct-Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Particles</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Nồng độ</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ /min</td>
<td class="text-center" colspan="2">85 ℓ /min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement; must meet values in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" colspan="2">For NaCl particles<br />
Load up to 100mg</td>
<td class="text-left" colspan="2">For DOP particles<br />
Load up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or higher</td>
<td>RL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or higher</td>
<td>RL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or higher</td>
<td>RL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or higher</td>
<td>DL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or higher</td>
<td>DL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or higher</td>
<td>DL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ /min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>Values in ( ) are for products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col">Exhalation valve leak test</td>
<td>– Internal pressure must drop immediately during suction.<br />
– Time for internal pressure to return to normal must be 15 seconds or more.</td>
</tr>
<tr>
<th class="header-col"><strong>CO2 Concentration Increase</strong></th>
<td class="content-col" colspan="2">Measured using a test headform and artificial lung. The difference in CO2 concentration in inhaled air with and without the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space</strong></th>
<td class="content-col" colspan="2">Value calculated from the CO2 Concentration Increase Test.</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Particles</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">After dust accumulation at 85 ℓ/min, measurement is taken at 40 ℓ/min.</td>
</tr>
<tr>
<td class="header-sub">Dust Accumulation Amount</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Particles &amp; Efficiency </span><span class="bottom-left-text">Disposable / Replaceable</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" rowspan="2"><strong>Classification</strong><br />
<strong>(Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender"><strong>Test particle: Solid NaCl</strong></th>
<th class="bg-lavender"><strong>Test particle: Liquid DOP</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (≥ 80.0%)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (≥ 95.0%)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (≥ 99.9%)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (≥ 80.0%)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (≥ 95.0%)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (≥ 99.9%)</td>
</tr>
</tbody>
</table>
<h2>High Efficiency Filter + Face-Friendly Surface</h2>
<h3>2. Surface Engineering for a Better Facial Fit</h3>
<p>Even if a dust mask has a high collection efficiency filter, it is useless if dust leaks in through the facepiece seal. The primary cause of leakage is the “gap at the contact area when wearing the mask.” We consider the fit of the mask to be as important as the filter performance. Therefore, our company has developed technology to enhance the airtightness of the facial contact area.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" sizes="auto, (max-width: 247px) 100vw, 247px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg 775w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-227x300.jpg 227w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-768x1015.jpg 768w" alt="" width="247" height="326" /><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and easily adapts to body movements, ensuring wearing comfort and stability during use.</p>
<p><strong>HAWC Harness</strong><br />
The harness design ensures high tension and maximizes the “suction” effect when wearing the mask, guaranteeing an airtight seal on the face.<img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" sizes="auto, (max-width: 145px) 100vw, 145px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png 319w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014-267x300.png 267w" alt="" width="145" height="163" /></p>
<p><strong>Freeposition Under-Chin</strong><br />
The special shape of the facial contact area prevents dust entry. The nose section is adjustable for different sizes, ensuring a perfect fit for a wide range of facial dimensions (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" sizes="auto, (max-width: 192px) 100vw, 192px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png 410w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024-300x180.png 300w" alt="" width="192" height="115" /></p>
<p><strong data-start="56" data-end="112">Fit Status of the Freeposition Under-Chin Facepiece</strong><br data-start="112" data-end="115" />(Cross-sectional simulation to show the contact position between the mask and the chin).</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong>For large faces:</strong><br data-start="94" data-end="97" />Uses the outer section of the mask to adjust the fit around the chin.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td width="64"><strong>For small faces:</strong><br data-start="202" data-end="205" />Uses the inner section of the mask to adjust the fit around the chin.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Wearing Safety</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Internal Fit Checker</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed for various face shapes; the cushion naturally fits your face.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Utilizes a 3D poly-band harness that matches head shapes to enhance the feeling of fit and seal.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>Built-in fit checker allows for seal checks at any time (for models 1005, 1010A, 1015, 1180 series).</td>
</tr>
</tbody>
</table>
<p data-path-to-node="4,0,0"><b data-path-to-node="4,0,0" data-index-in-node="32">Headband Types<br />
</b>Please replace headbands on a regular basis.<b data-path-to-node="4,0,0" data-index-in-node="32"><br />
</b></p>
<p><img loading="lazy" decoding="async" class="size-medium wp-image-192603 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2-300x187.jpg" alt="" width="300" height="187" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2-300x187.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2-768x478.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-2.jpg 1024w" sizes="auto, (max-width: 300px) 100vw, 300px" /></p>
<h2>KOKEN LTD. Model 1111-03</h2>
<p>A protective mask with a double-layered structure for exhaust valve protection.</p>
<p data-start="135" data-end="170">Test Certification: Model Standard TM208<br />
Protection Factor: 10</p>
<p data-start="200" data-end="285">Key Features: Lightweight design weighing only 88g, providing efficient protection for the facial area.</p>
<p data-start="44" data-end="68">Replacement Filter: LAS-11</p>
<p data-start="44" data-end="68"><img loading="lazy" decoding="async" class="aligncenter wp-image-56471" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-103215.png" alt="" width="210" height="241" /></p>
<ul>
<li data-start="46" data-end="83">Facepiece gasket</li>
<li data-start="87" data-end="112">Silicone material</li>
<li data-start="116" data-end="146">Low inhalation resistance</li>
</ul>
<p data-start="70" data-end="83">Options:</p>
<ul>
<li data-start="86" data-end="107">Fit Tester Type G</li>
<li data-start="110" data-end="131">Moisture Sponge Type A</li>
</ul>
<div class="spec-table-container">
<table class="spec-table">
<tbody>
<tr>
<th class="col-label"><strong>Particle Collection Efficiency</strong></th>
<td class="col-value">
<div class="value-wrapper">95.0% or higher<br />
(Average 98.5%)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">80Pa or less<br />
(Average 63Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">55Pa or less<br />
(Average 32Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance Increase</strong></th>
<td class="col-value">
<div class="value-wrapper">―<br />
(Average 131Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-value">
<div class="value-wrapper">104g or less<br />
(Average 88g)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Harness</strong></th>
<td class="col-value">RB Type</td>
</tr>
</tbody>
</table>
</div>
<p data-start="133" data-end="155">Replacement Accessories:</p>
<ul>
<li>Inhalation Valve: Type 36</li>
<li>Exhalation Valve: Type T-6K</li>
</ul>
<p><strong>▲ Shared Replacement Parts for 6 Models (1181R-03, 1121R-08, 1191SD-03, etc.)</strong></p>
<ul>
<li>Inhalation valve: circular type</li>
<li>Moisture sponge: oval type</li>
<li>Replacement filters · Accessories (optional)</li>
</ul>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong>LAS-52</strong> <em>(for Model 1181R)</em></td>
<td width="64"><strong>LAS-52C</strong> <em>(for Model 1181RC)</em></td>
<td width="64"><strong>LAS-1</strong> <em>(for Models 1121R, 1121RX, 1191SD, 1191D)</em></td>
<td width="64"><strong>LAS-51</strong> <em>(for Model 1180)</em></td>
<td width="64"><strong>LAS-51C</strong> <em>(for Model 1180C)</em></td>
<td width="64"><strong>KBC Filter for 1121 / 1191</strong><br data-start="68" data-end="71" /><em>(Ozone and organic odor removal – pack of 5)</em><br data-start="118" data-end="121" />For models: 1121R / 1121RX / 1191SD / 1191D / 1122R<br data-start="184" data-end="187" />(Optional)</td>
<td width="64"><strong>Fit Checker – Type F</strong><br data-start="245" data-end="248" />For models: 1181R, 1181RC, 1121R, 1121RX, 1191SD, 1191D<br data-start="315" data-end="318" />(Optional)</td>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-54448" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152816-removebg-preview.png" alt="" width="175" height="122" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-54447" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152823-removebg-preview.png" alt="" width="174" height="124" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-54446" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152827-removebg-preview.png" alt="" width="176" height="136" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-54445" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152834-removebg-preview.png" alt="" width="162" height="114" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-54444" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152839-removebg-preview.png" alt="" width="155" height="123" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-54443" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152848-removebg-preview.png" alt="" width="232" height="121" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-54442" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152853-removebg-preview.png" alt="" width="254" height="139" /></td>
</tr>
<tr>
<td height="19">Screw-on – pack of 2</td>
<td>Screw-on – pack of 2</td>
<td>Pack of 2</td>
<td>Screw-on – pack of 2</td>
<td>Screw-on – pack of 2</td>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<ul>
<li data-start="69" data-end="170">Under-Chin design: Special curved shape improves seal at the facial contact area.</li>
<li data-start="174" data-end="309">Silicone: Soft, skin-friendly material for a comfortable fit. The mask uses a silicone seal.</li>
<li data-start="313" data-end="392">Size S Available: Size S is available for users with smaller faces.</li>
<li data-start="396" data-end="516">Low Inhalation Resistance: Uses Alpha Ring filters with low breathing resistance, suitable for long work hours.</li>
<li data-start="520" data-end="637">Speaking Diaphragm: Allows communication and commands without removing the mask.</li>
<li data-start="641" data-end="749">Activated Carbon: Simultaneously removes low-concentration ozone with activated carbon filters.</li>
<li data-start="753" data-end="867">Micron: High-efficiency electrostatic filter material, compatible with RL ratings.</li>
<li data-start="871" data-end="999">Fit Checker: Perform a fit test easily using the manual lever.</li>
</ul>
<table>
<tbody>
<tr>
<td class="xl65" rowspan="2" width="64" height="38">
<p data-start="31" data-end="62"><strong>Double-Layer Bonnet Structure</strong></p>
<p data-start="64" data-end="422">The exhalation valve is positioned inside the bonnet, shielding it from external factors like wind.<br data-start="152" data-end="155" />Exhaled air accumulated in the upper bonnet acts as a buffer (barrier), preventing direct external impact and protecting the valve.<br data-start="311" data-end="314" />This significantly improves exhalation valve performance and stability under real usage conditions.</p>
</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56450" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447.png" sizes="auto, (max-width: 203px) 100vw, 203px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447.png 203w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-150x150.png 150w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-72x72.png 72w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-200x200.png 200w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-120x120.png 120w" alt="" width="203" height="202" /></td>
</tr>
<tr>
<td height="19"><strong>Note on Replacement</strong><br data-start="1030" data-end="1033" />Always replace consumable parts like filters early as recommended.</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/koken-1111-03-dust-mask/">Koken 1111-03 Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken 6061G-03 Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-6061g-03-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 12 Mar 2020 06:44:28 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192597</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: 6061G-03 Important Points When Wearing a Mask Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous dust. To protect yourself from inhaling particles while wearing a dust mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and the face are critical. 1. [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-6061g-03-dust-mask/">Koken 6061G-03 Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: 6061G-03</p>
<h2>Important Points When Wearing a Mask</h2>
<p>Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous dust. To protect yourself from inhaling particles while wearing a dust mask, both the performance of the filter and the &#8220;tight seal&#8221; (fit) between the mask and the face are critical.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Through unique technology, wool fibers are electrostatically charged, allowing electrostatic force to draw particles to the fiber surface. This is the primary mechanism for collecting particles. A high-density fiber structure is unnecessary, successfully integrating the two contrasting features: &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221; It consistently maintains the highest standard of performance and quality, making it an excellent long-term filter solution.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" sizes="auto, (max-width: 317px) 100vw, 317px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png 317w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333-300x204.png 300w" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" sizes="auto, (max-width: 316px) 100vw, 316px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png 316w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322-300x227.png 300w" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applied products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the fiber density of the filter enhances collection efficiency. To meet airflow resistance standards, paper filters traditionally require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into pristine circular shapes in a single process, creating the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" sizes="auto, (max-width: 329px) 100vw, 329px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751-300x116.png 300w" alt="" width="329" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" sizes="auto, (max-width: 321px) 100vw, 321px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png 321w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803-300x227.png 300w" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applied products are from page P.8 to P.11</p>
<p data-start="46" data-end="81"><strong>Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to model standards based on national regulations. These standards are diverse, ensuring that products meeting strict safety requirements are manufactured.</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong>Dust Respirator Standards</strong></th>
<td width="64">In addition to JIS standards, dust respirators are tested according to model standards based on national regulations. These standards are diverse, ensuring that products meeting strict safety requirements are manufactured.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the “Dust Respirator Standards”.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct-Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Particles</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ/min</td>
<td class="text-center" colspan="2">85 ℓ/min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Collection Efficiency</strong><br />
<strong>(Continuous measurement, must meet the value in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" colspan="2">For NaCl particles<br />
Load up to 100mg</td>
<td class="text-left" colspan="2">For DOP particles<br />
Load up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or higher</td>
<td>RL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or higher</td>
<td>RL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or higher</td>
<td>RL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or higher</td>
<td>DL1</td>
<td class="text-center">80.0% or higher</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or higher</td>
<td>DL2</td>
<td class="text-center">95.0% or higher</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or higher</td>
<td>DL3</td>
<td class="text-center">99.9% or higher</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test Flow Rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test Flow Rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>Values in ( ) are for products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col">Exhalation valve leak test</td>
<td>– Internal pressure must drop immediately during suction.<br />
– Time for internal pressure to return to normal must be 15 seconds or more.</td>
</tr>
<tr>
<th class="header-col"><strong>CO2 Concentration Increase</strong></th>
<td class="content-col" colspan="2">Measured using a test headform and artificial lung. The difference in CO2 concentration in inhaled air with and without the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space</strong></th>
<td class="content-col" colspan="2">Value calculated from the CO2 Concentration Increase Test.</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Particles</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">After dust accumulation at 85 ℓ/min, measurement is taken at 40 ℓ/min.</td>
</tr>
<tr>
<td class="header-sub">Dust Accumulation Amount</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Particles &amp; Efficiency </span><span class="bottom-left-text">Disposable / Replaceable</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" rowspan="2"><strong>Classification</strong><br />
<strong>(Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender"><strong>Test particle: Solid NaCl</strong></th>
<th class="bg-lavender"><strong>Test particle: Liquid DOP</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (≥ 80.0%)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (≥ 95.0%)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (≥ 99.9%)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (≥ 80.0%)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (≥ 95.0%)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (≥ 99.9%)</td>
</tr>
</tbody>
</table>
<h2>High Efficiency Filter + Face-Friendly Surface</h2>
<h3>2. Surface Engineering for a Better Facial Fit</h3>
<p>Even if a dust mask has a high collection efficiency filter, it is useless if dust leaks in through the facepiece seal. The primary cause of leakage is the “gap at the contact area when wearing the mask.” We consider the fit of the mask to be as important as the filter performance. Therefore, our company has developed technology to enhance the airtightness of the facial contact area.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" sizes="auto, (max-width: 247px) 100vw, 247px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg 775w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-227x300.jpg 227w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-768x1015.jpg 768w" alt="" width="247" height="326" /></p>
<p><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and easily adapts to body movements, ensuring wearing comfort and stability during use.</p>
<p><strong>HAWC Harness</strong><br />
The harness design ensures high tension and maximizes the “suction” effect when wearing the mask, guaranteeing an airtight seal on the face.<img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" sizes="auto, (max-width: 145px) 100vw, 145px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png 319w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014-267x300.png 267w" alt="" width="145" height="163" /></p>
<p><strong>Free-Position Under-Chin</strong><br />
The special shape of the facial contact area prevents dust entry. The nose section is adjustable for different sizes, ensuring a perfect fit for a wide range of facial dimensions (see image below).<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" sizes="auto, (max-width: 192px) 100vw, 192px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png 410w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024-300x180.png 300w" alt="" width="192" height="115" /></p>
<p><strong>Fit Status of the Free-Position Under-Chin Facepiece</strong><br data-start="112" data-end="115" />(Cross-sectional simulation to show the contact position between the mask and the chin).</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong>For large faces:</strong><br data-start="94" data-end="97" />Uses the outer section of the mask to adjust the fit around the chin.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td width="64"><strong>For small faces:</strong><br data-start="202" data-end="205" />Uses the inner section of the mask to adjust the fit around the chin.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Wearing Safety</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Internal Fit Checker</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed for various face shapes; the cushion naturally fits your face.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Utilizes a 3D poly-band harness that matches head shapes to enhance the feeling of fit and seal.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>Built-in fit checker allows for seal checks at any time (for models 1005, 1010A, 1015, 1180 series).</td>
</tr>
</tbody>
</table>
<p data-start="36" data-end="48"><strong>Harness Types</strong><br data-start="55" data-end="58" />Please replace the harness regularly.</p>
<p data-start="36" data-end="48"><img loading="lazy" decoding="async" class=" wp-image-192599 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-1-300x187.jpg" alt="" width="347" height="216" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-1-300x187.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-1-768x478.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-1.jpg 1024w" sizes="auto, (max-width: 347px) 100vw, 347px" /></p>
<h2>Replaceable Dust Mask – Mighty Micron Filter</h2>
<h3>Sakaki &#8211; Model 6061G-03</h3>
<p data-start="46" data-end="150">RL1<br data-start="107" data-end="110" />For protection against extremely low concentrations of Carbon Monoxide (CO)</p>
<p data-start="152" data-end="241">Model Assay Standard TM615<br data-start="221" data-end="224" />Protection Factor: 4</p>
<p data-start="243" data-end="261"><img loading="lazy" decoding="async" class="aligncenter wp-image-56474" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-14_104720-removebg-preview.png" alt="" width="303" height="223" /></p>
<ul>
<li data-start="264" data-end="273">Gasket</li>
<li data-start="276" data-end="285">Silicone</li>
<li data-start="288" data-end="296">Micron</li>
</ul>
<div class="spec-table-container">
<table class="spec-table">
<tbody>
<tr>
<th class="col-label"><strong>Particle Collection Efficiency</strong></th>
<td class="col-value">
<div class="value-wrapper">80.0% or more<br />
(Average 95.3%)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">70Pa or less<br />
(Average 58Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Exhalation Resistance</strong></th>
<td class="col-value">
<div class="value-wrapper">47Pa or less<br />
(Average 31Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Inhalation Resistance Increase</strong></th>
<td class="col-value">
<div class="value-wrapper">―<br />
(Average 91Pa)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Weight</strong></th>
<td class="col-value">
<div class="value-wrapper">286g or less<br />
(Average 259g)</div>
</td>
</tr>
<tr>
<th class="col-label"><strong>Harness</strong></th>
<td class="col-value">RB Type</td>
</tr>
</tbody>
</table>
</div>
<p data-start="46" data-end="73">Replacement Parts:</p>
<ul>
<li data-start="76" data-end="104">Inhalation Filter (Circular)</li>
<li data-start="107" data-end="131">Exhalation Valve (T-6K)</li>
<li data-start="134" data-end="173">Moisture Sponge (Cylindrical)</li>
</ul>
<p data-start="39" data-end="75"><strong>Regarding the Operating Environment for 6061G:</strong></p>
<p data-start="77" data-end="234">In activities such as roadwork or cooking, high levels of carbon dioxide (CO₂) may be generated, which must be removed while simultaneously discharging exhaust gases.</p>
<p data-start="236" data-end="248"><strong>Note:</strong></p>
<ul>
<li data-start="251" data-end="300">The 6061G-03 is not a gas mask.</li>
</ul>
<p data-start="303" data-end="318"><strong>Warning:</strong></p>
<ul>
<li data-start="323" data-end="402">Do not use in oxygen-deficient or toxic gas environments.</li>
<li data-start="407" data-end="539">Do not use in environments with CO concentrations above 50 ppm, as it can lead to fatal carbon monoxide poisoning.</li>
</ul>
<p><strong>Replacement Accessories and Options</strong><br data-start="72" data-end="75" />Accessory set for 6061G-02 filter material (includes filter)<img loading="lazy" decoding="async" class=" wp-image-192598 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-10-300x177.jpg" alt="" width="444" height="262" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-10-300x177.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-10-768x452.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-10.jpg 1024w" sizes="auto, (max-width: 444px) 100vw, 444px" /></p>
<p data-start="31" data-end="77"><strong>▲ Shared Replacement Parts for 6 Models (1181R-03, 1121R-08, 1191SD-03, etc.)</strong></p>
<ul>
<li data-start="80" data-end="104">Inhalation Valve: Circular type</li>
<li data-start="107" data-end="139">Moisture Sponge: Oval type</li>
</ul>
<h3 data-start="141" data-end="406">Replacement Filters · Optional Accessories</h3>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong>LAS-52</strong> <em>(for Model 1181R)</em></td>
<td width="64"><strong>LAS-52C</strong> <em>(for Model 1181RC)</em></td>
<td width="64"><strong>LAS-1</strong> <em>(for Models 1121R, 1121RX, 1191SD, 1191D)</em></td>
<td width="64"><strong>LAS-51</strong> <em>(for Model 1180)</em></td>
<td width="64"><strong>LAS-51C</strong> <em>(for Model 1180C)</em></td>
<td width="64"><strong>KBC Filter for 1121 / 1191</strong><br data-start="68" data-end="71" /><em>(Ozone &amp; organic odor removal – 5 sets)</em><br data-start="118" data-end="121" />For: 1121R / 1121RX / 1191SD / 1191D / 1122R<br data-start="184" data-end="187" />(Optional)</td>
<td width="64"><strong>Fit Test Device – Type F</strong><br data-start="245" data-end="248" />For: 1181R, 1181RC, 1121R, 1121RX, 1191SD, 1191D<br data-start="315" data-end="318" />(Optional)</td>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56448" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152816-removebg-preview.png" alt="" width="175" height="122" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56447" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152823-removebg-preview.png" alt="" width="174" height="124" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56446" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152827-removebg-preview.png" alt="" width="176" height="136" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56445" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152834-removebg-preview.png" alt="" width="162" height="114" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56444" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152839-removebg-preview.png" alt="" width="155" height="123" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56443" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152848-removebg-preview.png" alt="" width="232" height="121" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56442" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-13_152853-removebg-preview.png" alt="" width="254" height="139" /></td>
</tr>
<tr>
<td height="19">Screw-in – Pack of 2</td>
<td>Screw-in – Pack of 2</td>
<td>Pack of 2</td>
<td>Screw-in – Pack of 2</td>
<td>Screw-in – Pack of 2</td>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<ul>
<li data-start="69" data-end="170">Under Chin: Specialized curve enhances facial seal.</li>
<li data-start="174" data-end="309">Silicone: Soft, skin-friendly material for a comfortable wearing experience.</li>
<li data-start="313" data-end="392">Size S Available: Sizes for individuals with smaller faces.</li>
<li data-start="396" data-end="516">Low Respiratory Resistance: Alpha Ring filter allows for extended work periods.</li>
<li data-start="520" data-end="637">Speaking Diaphragm: Enables clear communication without mask removal.</li>
<li data-start="641" data-end="749">Activated Carbon: Effectively removes low-concentration ozone.</li>
<li data-start="753" data-end="867">Micron: High-performance electrostatic filter compliant with RL classification.</li>
<li data-start="871" data-end="999">Fit Checker: Lever mechanism for easy seal testing.</li>
</ul>
<table>
<tbody>
<tr>
<td class="xl65" rowspan="2" width="64" height="38">
<p data-start="31" data-end="62"><strong>Double-Layer Bonnet Structure</strong></p>
<p data-start="64" data-end="422">The exhalation valve is shielded inside the bonnet from external factors like wind. Exhaled air accumulated in the upper bonnet acts as a barrier, protecting the valve and improving stability in real-world conditions.</p>
</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56450" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447.png" sizes="auto, (max-width: 203px) 100vw, 203px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447.png 203w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-150x150.png 150w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-72x72.png 72w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-200x200.png 200w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-13-153447-120x120.png 120w" alt="" width="203" height="202" /></td>
</tr>
<tr>
<td height="19"><strong>Note on Replacement</strong><br data-start="1030" data-end="1033" />Always replace filters and wearable parts according to recommended schedules.</td>
</tr>
</tbody>
</table>The post <a href="https://koueitrading.com/global/product/koken-6061g-03-dust-mask/">Koken 6061G-03 Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken Hi-Luck 350 Disposable Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-hi-luck-350-disposable-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 12 Mar 2020 06:38:48 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192595</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: Hi-Luck 350 Important points when wearing a respirator Dust respirators use high-efficiency filters to prevent the inhalation of hazardous dust. To protect yourself from inhaling dust when wearing a dust respirator, the performance of this filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are extremely important. 1. [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-hi-luck-350-disposable-dust-mask/">Koken Hi-Luck 350 Disposable Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: Hi-Luck 350</p>
<h2>Important points when wearing a respirator</h2>
<p>Dust respirators use high-efficiency filters to prevent the inhalation of hazardous dust. To protect yourself from inhaling dust when wearing a dust respirator, the performance of this filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are extremely important.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Through unique technology, the sheep wool is electrostatically charged, and this electrostatic force draws particles to the fiber surface. This is the primary mechanism for collecting particles. A high-density fiber structure is not required, thus integrating the two contrasting features of &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221;</p>
<p>It consistently maintains the highest standard of performance and quality, and has been utilized for a long time as an outstanding filter.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" sizes="auto, (max-width: 317px) 100vw, 317px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png 317w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333-300x204.png 300w" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" sizes="auto, (max-width: 316px) 100vw, 316px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png 316w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322-300x227.png 300w" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applicable products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the filter&#8217;s fiber density improves collection efficiency. To meet airflow resistance standards, paper filters require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into a pristine circular shape in a single process to create the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" sizes="auto, (max-width: 329px) 100vw, 329px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751-300x116.png 300w" alt="" width="329" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" sizes="auto, (max-width: 321px) 100vw, 321px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png 321w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803-300x227.png 300w" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applicable products are from P.8 to P.11</p>
<p data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to national assay standards based on national regulations. The contents of these standards are comprehensive, ensuring the manufacture of products that meet strict safety requirements.</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td width="64">In addition to JIS standards, dust respirators are tested according to national assay standards based on national regulations. The contents of these standards are comprehensive, ensuring the manufacture of products that meet strict safety requirements.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the &#8220;Dust Respirator Standards&#8221;.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Aerosol</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride) particles</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate) particles</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ/min</td>
<td class="text-center" colspan="2">85 ℓ/min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement, must meet the value in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" colspan="2">For NaCl test aerosol<br />
Loaded up to 100mg</td>
<td class="text-left" colspan="2">For DOP test aerosol<br />
Loaded up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or more</td>
<td>RL1</td>
<td class="text-center">80.0% or more</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or more</td>
<td>RL2</td>
<td class="text-center">95.0% or more</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or more</td>
<td>RL3</td>
<td class="text-center">99.9% or more</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or more</td>
<td>DL1</td>
<td class="text-center">80.0% or more</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or more</td>
<td>DL2</td>
<td class="text-center">95.0% or more</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or more</td>
<td>DL3</td>
<td class="text-center">99.9% or more</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>( ) indicates products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col">Exhalation valve operation leak test</td>
<td>&#8211; When air is drawn, the internal pressure must decrease immediately<br />
&#8211; The time for internal pressure to return to normal atmospheric pressure must be 15 seconds or more</td>
</tr>
<tr>
<th class="header-col"><strong>Carbon Dioxide (CO2) Concentration Increase</strong></th>
<td class="content-col" colspan="2">Using a test headform and an artificial lung to inhale/exhale air containing CO2. The difference in CO2 concentration in the inhaled air between wearing and not wearing the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space Volume</strong></th>
<td class="content-col" colspan="2">Calculated from the (Carbon Dioxide Concentration Increase Test)</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Aerosol</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">Measured at 40 ℓ/min after loading test dust at 85 ℓ/min</td>
</tr>
<tr>
<td class="header-sub">Amount loaded onto dust respirator</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Aerosol and Collection Efficiency </span><span class="bottom-left-text">Disposable Type<br />
/ Replaceable Type</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" rowspan="2"><strong>Classification</strong><br />
<strong>(Particle Collection Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender"><strong>Test aerosol is solid Sodium Chloride (NaCl)</strong></th>
<th class="bg-lavender"><strong>Test aerosol is liquid Dioctyl Phthalate (DOP)</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
</tbody>
</table>
<h2>High-Performance Filter + Facepiece Designed for Easy Fit</h2>
<h3>2. Facepiece Fit Technology</h3>
<p>Even if a dust respirator has a high collection efficiency filter, it is meaningless if dust leaks through the face-to-mask seal during use. This is primarily caused by a &#8220;gap at the face contact area when worn.&#8221;</p>
<p>We consider mask fit to be just as important as filter performance. Therefore, our company has long developed technologies to enhance the airtightness of the facepiece seal.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" sizes="auto, (max-width: 247px) 100vw, 247px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg 775w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-227x300.jpg 227w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-768x1015.jpg 768w" alt="" width="247" height="326" /></p>
<p><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and effortlessly adapts to facial movements, ensuring a comfortable fit. The material also remains stable during use.</p>
<p><strong>HAWC Lip Structure</strong><br />
The lip design ensures a high degree of adhesion, maximizing the &#8220;suction cup&#8221; effect when wearing the mask to ensure an airtight facial seal.<img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" sizes="auto, (max-width: 145px) 100vw, 145px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png 319w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014-267x300.png 267w" alt="" width="145" height="163" /></p>
<p><strong>Free Position Under Chin</strong><br />
The unique curve of the face contact area prevents dust from leaking in. By aligning the nose portion first, it accommodates various facial dimensions, providing a secure fit for a wide range of face sizes (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" sizes="auto, (max-width: 192px) 100vw, 192px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png 410w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024-300x180.png 300w" alt="" width="192" height="115" /></p>
<p><strong data-start="56" data-end="112">Fit Status of the Free Position Under Chin Mask</strong><br data-start="112" data-end="115" />(Simulated image with the mask cut away to clearly show where it contacts the chin).</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong data-start="56" data-end="94">For individuals with large faces:</strong><br data-start="94" data-end="97" />The outer section of the mask rests naturally against the chin to provide a proper fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td width="64"><strong data-start="164" data-end="202">For individuals with small faces:</strong><br data-start="202" data-end="205" />The inner section of the mask naturally positions itself against the chin to secure the fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Wearing Stability</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Built-in Fit Checker</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed to naturally conform to various facial sizes and shapes, providing a seamless fit.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Uses a 3D-shaped polyband harness that conforms to the shape of the head, cradling it to enhance fit and sealing performance.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>A built-in fit checker allows you to test the mask&#8217;s seal at any time (available for the 1005, 1010A, 1015, and 1180 series).</td>
</tr>
</tbody>
</table>
<h2>Disposable Mask</h2>
<p data-start="64" data-end="89"><strong data-start="64" data-end="89">FF Lip (Free Fit Lip)</strong></p>
<p data-start="91" data-end="595">The most important factor when choosing a disposable mask is ensuring a secure fit to the face. The reason the Hi-Lack series provides an excellent fit is that the FF Lip has a shape that easily adapts to various facial sizes and contours.</p>
<p data-start="91" data-end="595">The FF Lip features a wide surface area and a soft design, providing superior sealing capability while easily conforming to facial movements. This prevents seal displacement during use, delivering a natural and tight seal as if the mask were custom-made.</p>
<p data-start="91" data-end="595"><img loading="lazy" decoding="async" class="aligncenter wp-image-56478" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954.png" alt="" width="254" height="233" /></p>
<p data-start="91" data-end="595"><strong>Three Types of Straps to Choose From</strong></p>
<p data-start="91" data-end="595"><img loading="lazy" decoding="async" class=" wp-image-192566 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-300x79.jpg" alt="" width="516" height="136" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-300x79.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-768x203.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1.jpg 1024w" sizes="auto, (max-width: 516px) 100vw, 516px" /></p>
<p data-start="22" data-end="80"><strong data-start="22" data-end="80">Adjusting the Strap Length for a Perfect Fit</strong></p>
<p data-start="82" data-end="266">To ensure proper mask adhesion, &#8220;adjusting the strap length&#8221; is crucial. If the straps do not fit well or if a gap forms during work, it is unsafe.</p>
<ul>
<li data-start="270" data-end="315">The straps must be positioned correctly for stability.</li>
<li data-start="318" data-end="356">Adjust the length to ensure a snug fit.</li>
</ul>
<p data-start="22" data-end="57"><strong data-start="22" data-end="57">Uses a Synthetic Rubber Strap</strong></p>
<p data-start="59" data-end="154">The strap absorbs moisture well, feels soft against the skin, and prevents allergic reactions associated with natural rubber.</p>
<p data-start="59" data-end="154"><img loading="lazy" decoding="async" class="aligncenter wp-image-56480" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421.png" alt="" width="195" height="178" /></p>
<p data-start="156" data-end="243" data-is-last-node="" data-is-only-node="">The strap length can be adjusted while wearing the mask to accommodate different facial sizes.</p>
<p data-start="22" data-end="62"><strong data-start="22" data-end="62">Easy to Wear &#8211; T-Type (Hook Style)</strong></p>
<ul>
<li data-start="66" data-end="83">Does not tangle hair.</li>
<li data-start="86" data-end="122">Adjustable strap length.</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56481" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505.png" alt="" width="207" height="150" /></p>
<p data-start="124" data-end="203" data-is-last-node="" data-is-only-node="">Simply pull the strap over the head, wrap it around the sides, and secure it with the hook.</p>
<p data-start="0" data-end="46"><strong data-start="0" data-end="46">Even Softer Wearing Feel (TK Hook Style)</strong></p>
<ul>
<li data-start="50" data-end="67">Does not tangle hair.</li>
<li data-start="70" data-end="121">Adjustable strap length and tension.</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56482" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626.png" alt="" width="198" height="145" /></p>
<p data-start="123" data-end="225" data-is-last-node="" data-is-only-node="">The tightness of the upper and lower straps can be individually adjusted for an optimal fit, reducing pressure on the ears.</p>
<h2 data-start="123" data-end="225">High-Luck Series</h2>
<h3 data-start="0" data-end="35"><strong data-start="0" data-end="35">Information on Hi-Luck 350 Respirator</strong></h3>
<p data-start="36" data-end="91">DS2 Standard: Achieves a particle collection efficiency of 95% or higher. Widely easy to use, this model also complies with N95 standards.</p>
<p data-start="36" data-end="91"><img loading="lazy" decoding="async" class="aligncenter wp-image-56483" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-112214.png" alt="" width="241" height="205" /></p>
<ul>
<li>FF (Form Fit)</li>
<li>Shape Recovery</li>
</ul>
<p data-start="39" data-end="118"><strong data-start="39" data-end="53">Standard</strong>: Complies with national standards TM339 and TM609, Assigned Protection Factor of 10.</p>
<p data-start="121" data-end="273"><strong data-start="121" data-end="128">N95</strong>:</p>
<ul>
<li data-start="121" data-end="273">Complies with NIOSH (National Institute for Occupational Safety and Health) regulations with an air filtration efficiency of 95% or higher.</li>
<li data-start="276" data-end="335">NaCl Dust Filtration: The particle size of NaCl is 0.075 ± 0.02 µm.</li>
<li data-start="338" data-end="459">Note: Only the 2-strap model of the 350 series complies with NIOSH standards; this does not include the hook style model (350T).</li>
</ul>
<h3><strong data-start="61" data-end="80">Bipromicron Filter </strong>(Models 650, 655)</h3>
<p data-start="99" data-end="285">This is a high-performance filter recycled from the leftover raw materials of molded high-efficiency filters. The filter material is repurposed and processed into a new high-performance filter.</p>
<p data-start="287" data-end="456"><strong>Recycled Material</strong><br data-start="307" data-end="310" />We are effectively utilizing waste as a resource. This is an eco-friendly filter created from recycled filter materials.</p>
<p data-start="287" data-end="456"><img loading="lazy" decoding="async" class=" wp-image-192565 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-300x187.jpg" alt="" width="486" height="303" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-300x187.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-768x478.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1.jpg 1024w" sizes="auto, (max-width: 486px) 100vw, 486px" /></p>
<h3 data-start="34" data-end="87"><strong data-start="34" data-end="66">Shape Recovery Structure </strong>(Models 550, 555 excluded)</h3>
<p data-start="89" data-end="274">The inside of the mask is reinforced with a shape-retaining mesh so that it does not lose its form when folded. This ensures the mask maintains its shape even when folded during breaks or short intervals.</p>
<p data-start="276" data-end="289"><strong>Hygiene</strong></p>
<ul>
<li data-start="292" data-end="379">When not in use, you can fold the mask closed to prevent dust from entering the inside of the facepiece.</li>
<li data-start="382" data-end="488">During hot or cold seasons, moisture from breathing may penetrate the mask, but this does not affect its performance.</li>
</ul>
<h3 data-start="34" data-end="162"><strong data-start="34" data-end="63">Completely Incinerable</strong></h3>
<p>The material contains no chloride compounds, so it does not generate toxic gases like dioxins when incinerated.</p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56485" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-113256.png" alt="" width="137" height="164" /></p>
<p><strong data-start="164" data-end="198">Metal-Free Design</strong><br data-start="198" data-end="201" />With the FF Lip design, an excellent seal is achieved without the use of metal parts such as nose clips.</p>
<h3>Features:</h3>
<ul>
<li data-start="36" data-end="124"><strong data-start="36" data-end="42">FF Lip</strong>: The Free Fit Lip design improves airtightness and provides a secure fit to the face.</li>
<li data-start="127" data-end="220"><strong data-start="127" data-end="149">Shape Recovery</strong>: Easily folds away during breaks or transit without losing its structural integrity.</li>
<li data-start="223" data-end="286"><strong data-start="223" data-end="233">Breathability</strong>: System that allows for easy airflow.</li>
<li data-start="289" data-end="372"><strong data-start="289" data-end="298">Bipro</strong>: Filter manufactured using recycled materials from ecological sources.</li>
<li data-start="375" data-end="455"><strong data-start="375" data-end="395">Activated Carbon</strong>: Filters out low levels of ozone gas, aiding in air purification.</li>
</ul>
<h3>Performance Specifications</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th class="header-main" colspan="2"><strong>Performance</strong></th>
<th><strong>Model</strong><br />
<strong>350 / 350T</strong></th>
<th><strong>Model</strong><br />
<strong>355 / 355T</strong></th>
<th><strong>Model</strong><br />
<strong>350TK</strong></th>
<th><strong>Model</strong><br />
<strong>355TK</strong></th>
<th><strong>Model</strong><br />
<strong>650 / 650T</strong></th>
<th><strong>Model</strong><br />
<strong>655 / 655T</strong></th>
<th><strong>Model</strong><br />
<strong>550</strong></th>
<th><strong>Model</strong><br />
<strong>555</strong></th>
<th><strong>Model</strong><br />
<strong>330</strong></th>
<th><strong>Model</strong><br />
<strong>335</strong></th>
</tr>
</thead>
<tbody>
<tr>
<th class="row-label" colspan="2"><strong>Particle Collection Efficiency</strong><br />
<strong><span class="small-text">(NaCl particles)</span></strong></th>
<td>95.0% or more<br />
(98.4%)</td>
<td>95.0% or more<br />
(97.9%)</td>
<td>95.0% or more<br />
(98.31%)</td>
<td>95.0% or more<br />
(98.18%)</td>
<td>95.0% or more<br />
(99.4%)</td>
<td>95.0% or more<br />
(99.0%)</td>
<td>80.0% or more<br />
(89.3%)</td>
<td>80.0% or more<br />
(88.6%)</td>
<td>80.0% or more<br />
(89.73%)</td>
<td>95.0% or more<br />
(98.46%)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Inhalation Resistance</strong></th>
<td>50Pa or less<br />
(35Pa)</td>
<td>50Pa or less<br />
(37Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>50Pa or less<br />
(39Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>52Pa or less<br />
(40Pa)</td>
<td>40Pa or less<br />
(29Pa)</td>
<td>43Pa or less<br />
(32Pa)</td>
<td>45Pa or less<br />
(28Pa)</td>
<td>70Pa or less<br />
(50Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Exhalation Resistance</strong></th>
<td>50Pa or less<br />
(35Pa)</td>
<td>36Pa or less<br />
(21Pa)</td>
<td>50Pa or less<br />
(35Pa)</td>
<td>36Pa or less<br />
(21Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>36Pa or less<br />
(19Pa)</td>
<td>40Pa or less<br />
(29Pa)</td>
<td>28Pa or less<br />
(18Pa)</td>
<td>45Pa or less<br />
(29Pa)</td>
<td>40Pa or less<br />
(22Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Inhalation Resistance Increase</strong></th>
<td>―<br />
(135Pa)</td>
<td>―<br />
(203Pa)</td>
<td>―<br />
(131Pa)</td>
<td>―<br />
(160Pa)</td>
<td>―<br />
(90Pa)</td>
<td>―<br />
(113Pa)</td>
<td>―<br />
(97Pa)</td>
<td>―<br />
(147Pa)</td>
<td>―<br />
(122Pa)</td>
<td>―<br />
(208Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>CO2 Concentration Increase</strong><br />
<strong>/ Dead Space</strong></th>
<td>1.0% or less / 400cm³ or less<br />
(0.45% / 178cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.41% / 165cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.42% / 166cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.39% / 156cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.37% / 149cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.39% / 156cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.73% / 293cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.71% / 283cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.38% / 152cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.34% / 136cm³)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Wet Resistance Value</strong></th>
<td>―<br />
(31Pa)</td>
<td>―<br />
(22Pa)</td>
<td>―<br />
(29Pa)</td>
<td>―<br />
(18Pa)</td>
<td>―<br />
(30Pa)</td>
<td>―<br />
(17Pa)</td>
<td>―<br />
(25Pa)</td>
<td>―<br />
(16Pa)</td>
<td>―<br />
(24Pa)</td>
<td>―<br />
(18Pa)</td>
</tr>
<tr>
<th class="row-label" rowspan="3"><strong>Weight</strong></th>
<th class="row-label"><strong>2-Strap Type</strong></th>
<td>Model 350: 12.1g or less<br />
(9.1g)</td>
<td>Model 355: 14.1g or less<br />
(11.1g)</td>
<td>―</td>
<td>―</td>
<td>Model 650: 12.6g or less<br />
(9.9g)</td>
<td>Model 655: 14.5g or less<br />
(11.8g)</td>
<td>12.3g or less (10.1g)</td>
<td>14.1g or less (11.8g)</td>
<td>―</td>
<td>―</td>
</tr>
<tr>
<th class="row-label"><strong>Hook Type</strong></th>
<td>Model 350T: 12.7g or less<br />
(9.7g)</td>
<td>Model 355T: 14.5g or less<br />
(11.5g)</td>
<td>―</td>
<td>―</td>
<td>Model 650T: 13.1g or less<br />
(10.2g)</td>
<td>Model 655T: 15.0g or less<br />
(12.4g)</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>―</td>
</tr>
<tr>
<th class="row-label"><strong>TK Hook Type</strong></th>
<td>―</td>
<td>―</td>
<td>13.3g or less<br />
(10.4g)</td>
<td>15.3g or less<br />
(12.3g)</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>12.5g or less<br />
(9.9g)</td>
<td>14.5g or less<br />
(11.7g)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Maximum Use Time Limit</strong></th>
<td>13 Hours</td>
<td>15 Hours</td>
<td>13 Hours</td>
<td>15 Hours</td>
<td>20 Hours</td>
<td>25 Hours</td>
<td>12 Hours</td>
<td>13 Hours</td>
<td>10 Hours</td>
<td>8 Hours</td>
</tr>
</tbody>
</table>
<p>Models 350TK, 355TK, 330, and 335 use the TK hook type strap. Models 350T, 355T, 650T, and 655T use the standard hook type strap.<br />
Values in ( ) indicate average values.</p>
<h3 data-start="34" data-end="59"><strong data-start="34" data-end="59">Regarding usage time:</strong></h3>
<p data-start="62" data-end="200">When using a disposable respirator, the maximum use time is specified according to the standards of the Japanese Society of Respiratory Protection Engineers.<br />
When supplied with 0.1g NaCl / minute at an airflow of 40L/minute, the usage time of this respirator will meet the Japanese national standard for dust respirators, until it exceeds 1.5 times the specified value.</p>
<p data-start="62" data-end="200">However, you must replace the mask in the following situations:</p>
<ul>
<li data-start="480" data-end="501">When breathing becomes difficult.</li>
<li data-start="506" data-end="537">When the mask is damaged or heavily soiled.</li>
<li data-start="542" data-end="566">When the mask becomes deformed.</li>
</ul>
<h3 class="table-title">Inward Leakage Rate</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th class="col-subject" rowspan="2"><strong>Test</strong><br />
<strong>Subject</strong></th>
<th><strong>Lip Width (cm)</strong></th>
<th><strong>Nose-Chin Distance (cm)</strong></th>
<th colspan="14"><strong>Leakage Rate (%)</strong></th>
</tr>
<tr>
<th><strong>Specification</strong></th>
<th><strong>Specification</strong></th>
<th><strong>Model</strong><br />
<strong>350</strong></th>
<th><strong>Model</strong><br />
<strong>350T</strong></th>
<th><strong>Model</strong><br />
<strong>355</strong></th>
<th><strong>Model</strong><br />
<strong>355T</strong></th>
<th><strong>Model</strong><br />
<strong>350TK</strong></th>
<th><strong>Model</strong><br />
<strong>355TK</strong></th>
<th><strong>Model</strong><br />
<strong>650</strong></th>
<th><strong>Model</strong><br />
<strong>650T</strong></th>
<th><strong>Model</strong><br />
<strong>655</strong></th>
<th><strong>Model</strong><br />
<strong>655T</strong></th>
<th><strong>Model</strong><br />
<strong>550</strong></th>
<th><strong>Model</strong><br />
<strong>555</strong></th>
<th><strong>Model</strong><br />
<strong>330</strong></th>
<th><strong>Model</strong><br />
<strong>335</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td class="col-subject">A</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">10.5 to<br />
less than 11.5</td>
<td>0.15</td>
<td>0.24</td>
<td>0.18</td>
<td>0.27</td>
<td>0.19</td>
<td>0.30</td>
<td>0.07</td>
<td>0.11</td>
<td>0.47</td>
<td>0.14</td>
<td>1.83</td>
<td>1.63</td>
<td>0.26</td>
<td>0.34</td>
</tr>
<tr>
<td class="col-subject">B</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.42</td>
<td>0.32</td>
<td>0.57</td>
<td>0.41</td>
<td>0.36</td>
<td>0.27</td>
<td>0.08</td>
<td>0.20</td>
<td>0.31</td>
<td>0.36</td>
<td>1.29</td>
<td>1.85</td>
<td>0.57</td>
<td>0.13</td>
</tr>
<tr>
<td class="col-subject">C</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.18</td>
<td>0.19</td>
<td>0.25</td>
<td>0.19</td>
<td>0.38</td>
<td>0.36</td>
<td>0.14</td>
<td>0.26</td>
<td>0.16</td>
<td>0.26</td>
<td>1.43</td>
<td>2.45</td>
<td>1.65</td>
<td>0.24</td>
</tr>
<tr>
<td class="col-subject">D</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">10.5 to<br />
less than 11.5</td>
<td>0.35</td>
<td>0.26</td>
<td>0.27</td>
<td>0.24</td>
<td>0.18</td>
<td>0.29</td>
<td>0.11</td>
<td>0.08</td>
<td>0.34</td>
<td>0.25</td>
<td>1.68</td>
<td>1.88</td>
<td>0.73</td>
<td>0.14</td>
</tr>
<tr>
<td class="col-subject">E</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.58</td>
<td>0.44</td>
<td>0.41</td>
<td>0.37</td>
<td>0.42</td>
<td>0.19</td>
<td>0.21</td>
<td>0.72</td>
<td>0.26</td>
<td>0.86</td>
<td>1.74</td>
<td>1.78</td>
<td>1.06</td>
<td>0.13</td>
</tr>
<tr>
<td class="col-subject">F</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.06</td>
<td>0.17</td>
<td>0.09</td>
<td>0.11</td>
<td>0.14</td>
<td>0.48</td>
<td>0.37</td>
<td>0.22</td>
<td>0.38</td>
<td>0.39</td>
<td>1.98</td>
<td>1.37</td>
<td>1.53</td>
<td>0.56</td>
</tr>
<tr>
<td class="col-subject">G</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">13.5 to<br />
less than 14.5</td>
<td>0.09</td>
<td>0.05</td>
<td>0.08</td>
<td>0.12</td>
<td>0.35</td>
<td>0.57</td>
<td>0.11</td>
<td>0.27</td>
<td>0.59</td>
<td>0.70</td>
<td>1.22</td>
<td>1.95</td>
<td>1.33</td>
<td>0.62</td>
</tr>
<tr>
<td class="col-subject">H</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.15</td>
<td>0.07</td>
<td>0.25</td>
<td>0.13</td>
<td>0.12</td>
<td>0.55</td>
<td>0.07</td>
<td>0.19</td>
<td>0.20</td>
<td>0.33</td>
<td>1.35</td>
<td>1.98</td>
<td>2.33</td>
<td>0.32</td>
</tr>
<tr>
<td class="col-subject">I</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.12</td>
<td>0.14</td>
<td>0.15</td>
<td>0.17</td>
<td>0.21</td>
<td>0.44</td>
<td>0.14</td>
<td>0.08</td>
<td>0.41</td>
<td>0.64</td>
<td>1.45</td>
<td>1.78</td>
<td>2.02</td>
<td>0.39</td>
</tr>
<tr>
<td class="col-subject">J</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">13.5 to<br />
less than 14.5</td>
<td>0.41</td>
<td>0.35</td>
<td>0.27</td>
<td>0.19</td>
<td>0.48</td>
<td>0.45</td>
<td>0.39</td>
<td>0.05</td>
<td>0.15</td>
<td>0.20</td>
<td>2.27</td>
<td>2.04</td>
<td>1.76</td>
<td>0.35</td>
</tr>
</tbody>
</table>
</div>
</div>The post <a href="https://koueitrading.com/global/product/koken-hi-luck-350-disposable-dust-mask/">Koken Hi-Luck 350 Disposable Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken Hi-Luck 355 Disposable Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-hi-luck-355-disposable-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 12 Mar 2020 06:33:40 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192593</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: Hi-Luck 355 Important points when wearing a respirator Dust respirators use high-efficiency filters to prevent the inhalation of hazardous dust. To protect yourself from inhaling dust when wearing a dust respirator, the performance of this filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are extremely important. 1. [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-hi-luck-355-disposable-dust-mask/">Koken Hi-Luck 355 Disposable Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: Hi-Luck 355</p>
<h2>Important points when wearing a respirator</h2>
<p>Dust respirators use high-efficiency filters to prevent the inhalation of hazardous dust. To protect yourself from inhaling dust when wearing a dust respirator, the performance of this filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are extremely important.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Through unique technology, the sheep wool is electrostatically charged, and this electrostatic force draws particles to the fiber surface. This is the primary mechanism for collecting particles. A high-density fiber structure is not required, thus integrating the two contrasting features of &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221;</p>
<p>It consistently maintains the highest standard of performance and quality, and has been utilized for a long time as an outstanding filter.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" sizes="auto, (max-width: 317px) 100vw, 317px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png 317w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333-300x204.png 300w" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" sizes="auto, (max-width: 316px) 100vw, 316px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png 316w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322-300x227.png 300w" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applicable products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the filter&#8217;s fiber density improves collection efficiency. To meet airflow resistance standards, paper filters require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into a pristine circular shape in a single process to create the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" sizes="auto, (max-width: 329px) 100vw, 329px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751-300x116.png 300w" alt="" width="329" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" sizes="auto, (max-width: 321px) 100vw, 321px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png 321w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803-300x227.png 300w" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applicable products are from P.8 to P.11</p>
<p data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to national assay standards based on national regulations. The contents of these standards are comprehensive, ensuring the manufacture of products that meet strict safety requirements.</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td width="64">In addition to JIS standards, dust respirators are tested according to national assay standards based on national regulations. The contents of these standards are comprehensive, ensuring the manufacture of products that meet strict safety requirements.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the &#8220;Dust Respirator Standards&#8221;.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Aerosol</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride) particles</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate) particles</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ/min</td>
<td class="text-center" colspan="2">85 ℓ/min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement, must meet the value in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" colspan="2">For NaCl test aerosol<br />
Loaded up to 100mg</td>
<td class="text-left" colspan="2">For DOP test aerosol<br />
Loaded up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or more</td>
<td>RL1</td>
<td class="text-center">80.0% or more</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or more</td>
<td>RL2</td>
<td class="text-center">95.0% or more</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or more</td>
<td>RL3</td>
<td class="text-center">99.9% or more</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or more</td>
<td>DL1</td>
<td class="text-center">80.0% or more</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or more</td>
<td>DL2</td>
<td class="text-center">95.0% or more</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or more</td>
<td>DL3</td>
<td class="text-center">99.9% or more</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>( ) indicates products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col">Exhalation valve operation leak test</td>
<td>&#8211; When air is drawn, the internal pressure must decrease immediately<br />
&#8211; The time for internal pressure to return to normal atmospheric pressure must be 15 seconds or more</td>
</tr>
<tr>
<th class="header-col"><strong>Carbon Dioxide (CO2) Concentration Increase</strong></th>
<td class="content-col" colspan="2">Using a test headform and an artificial lung to inhale/exhale air containing CO2. The difference in CO2 concentration in the inhaled air between wearing and not wearing the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space Volume</strong></th>
<td class="content-col" colspan="2">Calculated from the (Carbon Dioxide Concentration Increase Test)</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Aerosol</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">Measured at 40 ℓ/min after loading test dust at 85 ℓ/min</td>
</tr>
<tr>
<td class="header-sub">Amount loaded onto dust respirator</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Aerosol and Collection Efficiency </span><span class="bottom-left-text">Disposable Type<br />
/ Replaceable Type</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" rowspan="2"><strong>Classification</strong><br />
<strong>(Particle Collection Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender"><strong>Test aerosol is solid Sodium Chloride (NaCl)</strong></th>
<th class="bg-lavender"><strong>Test aerosol is liquid Dioctyl Phthalate (DOP)</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
</tbody>
</table>
<h2>High-Performance Filter + Facepiece Designed for Easy Fit</h2>
<h3>2. Facepiece Fit Technology</h3>
<p>Even if a dust respirator has a high collection efficiency filter, it is meaningless if dust leaks through the face-to-mask seal during use. This is primarily caused by a &#8220;gap at the face contact area when worn.&#8221;</p>
<p>We consider mask fit to be just as important as filter performance. Therefore, our company has long developed technologies to enhance the airtightness of the facepiece seal.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" sizes="auto, (max-width: 247px) 100vw, 247px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg 775w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-227x300.jpg 227w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-768x1015.jpg 768w" alt="" width="247" height="326" /></p>
<p><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and effortlessly adapts to facial movements, ensuring a comfortable fit. The material also remains stable during use.</p>
<p><strong>HAWC Lip Structure</strong><br />
The lip design ensures a high degree of adhesion, maximizing the &#8220;suction cup&#8221; effect when wearing the mask to ensure an airtight facial seal.<img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" sizes="auto, (max-width: 145px) 100vw, 145px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png 319w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014-267x300.png 267w" alt="" width="145" height="163" /></p>
<p><strong>Free Position Under Chin</strong><br />
The unique curve of the face contact area prevents dust from leaking in. By aligning the nose portion first, it accommodates various facial dimensions, providing a secure fit for a wide range of face sizes (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" sizes="auto, (max-width: 192px) 100vw, 192px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png 410w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024-300x180.png 300w" alt="" width="192" height="115" /></p>
<p><strong data-start="56" data-end="112">Fit Status of the Free Position Under Chin Mask</strong><br data-start="112" data-end="115" />(Simulated image with the mask cut away to clearly show where it contacts the chin).</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong data-start="56" data-end="94">For individuals with large faces:</strong><br data-start="94" data-end="97" />The outer section of the mask rests naturally against the chin to provide a proper fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td width="64"><strong data-start="164" data-end="202">For individuals with small faces:</strong><br data-start="202" data-end="205" />The inner section of the mask naturally positions itself against the chin to secure the fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Wearing Stability</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Fit Checker nội bộ</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed to naturally conform to various facial sizes and shapes, providing a seamless fit.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Uses a 3D-shaped polyband harness that conforms to the shape of the head, cradling it to enhance fit and sealing performance.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>A built-in fit checker allows you to test the mask&#8217;s seal at any time (available for the 1005, 1010A, 1015, and 1180 series).</td>
</tr>
</tbody>
</table>
<h2 data-start="39" data-end="62"><strong data-start="39" data-end="62">Disposable Dust Respirators</strong></h2>
<p data-start="64" data-end="89"><strong data-start="64" data-end="89">FF Lip (Free Fit Lip)</strong></p>
<p data-start="91" data-end="595">The most important factor when choosing a disposable mask is ensuring a secure fit to the face. The reason the Hi-Luck series provides an excellent fit is that the FF Lip has a shape that easily adapts to various facial sizes and contours.</p>
<p data-start="91" data-end="595">The FF Lip features a wide surface area and a soft design, providing superior sealing capability while easily conforming to facial movements. This prevents seal displacement during use, delivering a natural and tight seal as if the mask were custom-made.</p>
<p data-start="91" data-end="595"><img loading="lazy" decoding="async" class="aligncenter wp-image-56478" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954.png" sizes="auto, (max-width: 254px) 100vw, 254px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954.png 525w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954-300x275.png 300w" alt="" width="254" height="233" /></p>
<p data-start="91" data-end="595"><strong>Three Types of Straps to Choose From</strong></p>
<p data-start="91" data-end="595"><img loading="lazy" decoding="async" class=" wp-image-192566 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-300x79.jpg" alt="" width="554" height="146" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-300x79.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-768x203.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1.jpg 1024w" sizes="auto, (max-width: 554px) 100vw, 554px" /></p>
<p data-start="22" data-end="80"><strong data-start="22" data-end="80">Adjusting the Strap Length for a Perfect Fit</strong></p>
<p data-start="82" data-end="266">To ensure proper mask adhesion, &#8220;adjusting the strap length&#8221; is crucial. If the straps do not fit well or if a gap forms during work, it is unsafe.</p>
<ul>
<li data-start="270" data-end="315">The straps must be positioned correctly for stability.</li>
<li data-start="318" data-end="356">Adjust the length to ensure a snug fit.</li>
</ul>
<p data-start="22" data-end="57"><strong data-start="22" data-end="57">Uses a Synthetic Rubber Strap</strong></p>
<p data-start="59" data-end="154">The strap absorbs moisture well, feels soft against the skin, and prevents allergic reactions associated with natural rubber.</p>
<p data-start="59" data-end="154"><img loading="lazy" decoding="async" class="aligncenter wp-image-56480" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421.png" sizes="auto, (max-width: 195px) 100vw, 195px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421-300x274.png 300w" alt="" width="195" height="178" /></p>
<p data-start="156" data-end="243" data-is-last-node="" data-is-only-node="">The strap length can be adjusted while wearing the mask to accommodate different facial sizes.</p>
<p data-start="22" data-end="62"><strong data-start="22" data-end="62">Easy to Wear &#8211; T-Type (Hook Style)</strong></p>
<ul>
<li data-start="66" data-end="83">Does not tangle hair.</li>
<li data-start="86" data-end="122">Adjustable strap length.</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56481" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505.png" sizes="auto, (max-width: 207px) 100vw, 207px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505.png 312w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505-300x217.png 300w" alt="" width="207" height="150" /></p>
<p data-start="124" data-end="203" data-is-last-node="" data-is-only-node="">Simply pull the strap over the head, wrap it around the sides, and secure it with the hook.</p>
<p data-start="0" data-end="46"><strong data-start="0" data-end="46">Even Softer Wearing Feel (TK Hook Style)</strong></p>
<ul>
<li data-start="50" data-end="67">Does not tangle hair.</li>
<li data-start="70" data-end="121">Adjustable strap length and tension.</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56482" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626.png" sizes="auto, (max-width: 198px) 100vw, 198px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626.png 313w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626-300x219.png 300w" alt="" width="198" height="145" /></p>
<p data-start="123" data-end="225" data-is-last-node="" data-is-only-node="">The tightness of the upper and lower straps can be individually adjusted for an optimal fit, reducing pressure on the ears.</p>
<h2 data-start="123" data-end="225">Hi-Luck Series</h2>
<h3 data-start="59" data-end="94"><strong data-start="59" data-end="94">Information on Hi-Luck 655-02 Respirator</strong></h3>
<p data-start="98" data-end="147">DS2 Standard: Achieves a filtration efficiency of 95% or higher. Equipped with an exhalation valve design. This minimizes breathing condensation inside the mask and makes the inhalation/exhalation process easier.</p>
<p data-start="98" data-end="147"><img loading="lazy" decoding="async" class="wp-image-56498 aligncenter" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-125112.png" alt="" width="234" height="217" /></p>
<ul>
<li data-start="50" data-end="80">FF (Free Fit Lip)</li>
<li data-start="83" data-end="134">Shape Recovery</li>
<li data-start="137" data-end="183">Exhalation Valve</li>
<li data-start="186" data-end="213">Bipro Filter</li>
</ul>
<p><strong data-start="325" data-end="340">Standard:</strong> Complies with TM598 certification, Assigned Protection Factor of 10.</p>
<h3><strong data-start="61" data-end="80">Bipromicron Filter </strong>(Models 650, 655)</h3>
<p data-start="99" data-end="285">This is a high-performance filter recycled from the leftover raw materials of molded high-efficiency filters. The filter material is repurposed and processed into a new high-performance filter.</p>
<p data-start="287" data-end="456"><strong>Recycled Material</strong><br data-start="307" data-end="310" />We are effectively utilizing waste as a resource. This is an eco-friendly filter created from recycled filter materials.</p>
<p data-start="287" data-end="456"><img loading="lazy" decoding="async" class=" wp-image-192565 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-300x187.jpg" alt="" width="438" height="273" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-300x187.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-768x478.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1.jpg 1024w" sizes="auto, (max-width: 438px) 100vw, 438px" /></p>
<h3 data-start="34" data-end="87"><strong data-start="34" data-end="66">Shape Recovery Structure </strong>(Models 550, 555 excluded)</h3>
<p data-start="89" data-end="274">The inside of the mask is reinforced with a shape-retaining mesh so that it does not lose its form when folded. This ensures the mask maintains its shape even when folded during breaks or short intervals.</p>
<p data-start="276" data-end="289"><strong>Hygiene</strong></p>
<ul>
<li data-start="292" data-end="379">When not in use, you can fold the mask closed to prevent dust from entering the inside of the facepiece.</li>
<li data-start="382" data-end="488">During hot or cold seasons, moisture from breathing may penetrate the mask, but this does not affect its performance.</li>
</ul>
<h3 data-start="34" data-end="162"><strong data-start="34" data-end="63">Completely Incinerable</strong></h3>
<p>The material contains no chloride compounds, so it does not generate toxic gases like dioxins when incinerated.</p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56485" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-113256.png" alt="" width="137" height="164" /></p>
<p><strong data-start="164" data-end="198">Metal-Free Design</strong><br data-start="198" data-end="201" />With the FF Lip design, an excellent seal is achieved without the use of metal parts such as nose clips.</p>
<h3>Features:</h3>
<ul>
<li data-start="36" data-end="124"><strong data-start="36" data-end="42">FF Lip</strong>: The Free Fit Lip design improves airtightness and provides a secure fit to the face.</li>
<li data-start="127" data-end="220"><strong data-start="127" data-end="149">Shape Recovery</strong>: Easily folds away during breaks or transit without losing its structural integrity.</li>
<li data-start="223" data-end="286"><strong data-start="223" data-end="233">Exhalation Valve</strong>: Facilitates easier exhalation and reduces heat buildup.</li>
<li data-start="289" data-end="372"><strong data-start="289" data-end="298">Bipro</strong>: Filter manufactured using recycled materials from ecological sources.</li>
<li data-start="375" data-end="455"><strong data-start="375" data-end="395">Activated Carbon</strong>: Filters out low levels of ozone gas, aiding in air purification.</li>
</ul>
<h3>Performance Specifications</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th class="header-main" colspan="2"><strong>Performance</strong></th>
<th><strong>Model</strong><br />
<strong>350 / 350T</strong></th>
<th><strong>Model</strong><br />
<strong>355 / 355T</strong></th>
<th><strong>Model</strong><br />
<strong>350TK</strong></th>
<th><strong>Model</strong><br />
<strong>355TK</strong></th>
<th><strong>Model</strong><br />
<strong>650 / 650T</strong></th>
<th><strong>Model</strong><br />
<strong>655 / 655T</strong></th>
<th><strong>Model</strong><br />
<strong>550</strong></th>
<th><strong>Model</strong><br />
<strong>555</strong></th>
<th><strong>Model</strong><br />
<strong>330</strong></th>
<th><strong>Model</strong><br />
<strong>335</strong></th>
</tr>
</thead>
<tbody>
<tr>
<th class="row-label" colspan="2"><strong>Particle Collection Efficiency</strong><br />
<strong><span class="small-text">(NaCl particles)</span></strong></th>
<td>95.0% or more<br />
(98.4%)</td>
<td>95.0% or more<br />
(97.9%)</td>
<td>95.0% or more<br />
(98.31%)</td>
<td>95.0% or more<br />
(98.18%)</td>
<td>95.0% or more<br />
(99.4%)</td>
<td>95.0% or more<br />
(99.0%)</td>
<td>80.0% or more<br />
(89.3%)</td>
<td>80.0% or more<br />
(88.6%)</td>
<td>80.0% or more<br />
(89.73%)</td>
<td>95.0% or more<br />
(98.46%)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Inhalation Resistance</strong></th>
<td>50Pa or less<br />
(35Pa)</td>
<td>50Pa or less<br />
(37Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>50Pa or less<br />
(39Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>52Pa or less<br />
(40Pa)</td>
<td>40Pa or less<br />
(29Pa)</td>
<td>43Pa or less<br />
(32Pa)</td>
<td>45Pa or less<br />
(28Pa)</td>
<td>70Pa or less<br />
(50Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Exhalation Resistance</strong></th>
<td>50Pa or less<br />
(35Pa)</td>
<td>36Pa or less<br />
(21Pa)</td>
<td>50Pa or less<br />
(35Pa)</td>
<td>36Pa or less<br />
(21Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>36Pa or less<br />
(19Pa)</td>
<td>40Pa or less<br />
(29Pa)</td>
<td>28Pa or less<br />
(18Pa)</td>
<td>45Pa or less<br />
(29Pa)</td>
<td>40Pa or less<br />
(22Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Inhalation Resistance Increase</strong></th>
<td>―<br />
(135Pa)</td>
<td>―<br />
(203Pa)</td>
<td>―<br />
(131Pa)</td>
<td>―<br />
(160Pa)</td>
<td>―<br />
(90Pa)</td>
<td>―<br />
(113Pa)</td>
<td>―<br />
(97Pa)</td>
<td>―<br />
(147Pa)</td>
<td>―<br />
(122Pa)</td>
<td>―<br />
(208Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>CO2 Concentration Increase</strong><br />
<strong>/ Dead Space</strong></th>
<td>1.0% or less / 400cm³ or less<br />
(0.45% / 178cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.41% / 165cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.42% / 166cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.39% / 156cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.37% / 149cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.39% / 156cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.73% / 293cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.71% / 283cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.38% / 152cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.34% / 136cm³)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Wet Resistance Value</strong></th>
<td>―<br />
(31Pa)</td>
<td>―<br />
(22Pa)</td>
<td>―<br />
(29Pa)</td>
<td>―<br />
(18Pa)</td>
<td>―<br />
(30Pa)</td>
<td>―<br />
(17Pa)</td>
<td>―<br />
(25Pa)</td>
<td>―<br />
(16Pa)</td>
<td>―<br />
(24Pa)</td>
<td>―<br />
(18Pa)</td>
</tr>
<tr>
<th class="row-label" rowspan="3"><strong>Weight</strong></th>
<th class="row-label"><strong>2-Strap Type</strong></th>
<td>Model 350: 12.1g or less<br />
(9.1g)</td>
<td>Model 355: 14.1g or less<br />
(11.1g)</td>
<td>―</td>
<td>―</td>
<td>Model 650: 12.6g or less<br />
(9.9g)</td>
<td>Model 655: 14.5g or less<br />
(11.8g)</td>
<td>12.3g or less (10.1g)</td>
<td>14.1g or less (11.8g)</td>
<td>―</td>
<td>―</td>
</tr>
<tr>
<th class="row-label"><strong>Hook Type</strong></th>
<td>Model 350T: 12.7g or less<br />
(9.7g)</td>
<td>Model 355T: 14.5g or less<br />
(11.5g)</td>
<td>―</td>
<td>―</td>
<td>Model 650T: 13.1g or less<br />
(10.2g)</td>
<td>Model 655T: 15.0g or less<br />
(12.4g)</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>―</td>
</tr>
<tr>
<th class="row-label"><strong>TK Hook Type</strong></th>
<td>―</td>
<td>―</td>
<td>13.3g or less<br />
(10.4g)</td>
<td>15.3g or less<br />
(12.3g)</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>12.5g or less<br />
(9.9g)</td>
<td>14.5g or less<br />
(11.7g)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Maximum Use Time Limit</strong></th>
<td>13 Hours</td>
<td>15 Hours</td>
<td>13 Hours</td>
<td>15 Hours</td>
<td>20 Hours</td>
<td>25 Hours</td>
<td>12 Hours</td>
<td>13 Hours</td>
<td>10 Hours</td>
<td>8 Hours</td>
</tr>
</tbody>
</table>
<p>Models 350TK, 355TK, 330, and 335 use the TK hook type strap. Models 350T, 355T, 650T, and 655T use the standard hook type strap.<br />
Values in ( ) indicate average values.</p>
<h3 data-start="34" data-end="59"><strong data-start="34" data-end="59">Regarding usage time:</strong></h3>
<p data-start="62" data-end="200">When using a disposable respirator, the maximum use time is specified according to the standards of the Japanese Society of Respiratory Protection Engineers.<br />
When supplied with 0.1g NaCl / minute at an airflow of 40L/minute, the usage time of this respirator will meet the Japanese national standard for dust respirators, until it exceeds 1.5 times the specified value.</p>
<p data-start="62" data-end="200">However, you must replace the mask in the following situations:</p>
<ul>
<li data-start="480" data-end="501">When breathing becomes difficult.</li>
<li data-start="506" data-end="537">When the mask is damaged or heavily soiled.</li>
<li data-start="542" data-end="566">When the mask becomes deformed.</li>
</ul>
<h3 class="table-title">Inward Leakage Rate</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th class="col-subject" rowspan="2"><strong>Test</strong><br />
<strong>Subject</strong></th>
<th><strong>Lip Width (cm)</strong></th>
<th><strong>Nose-Chin Distance (cm)</strong></th>
<th colspan="14"><strong>Leakage Rate (%)</strong></th>
</tr>
<tr>
<th><strong>Specification</strong></th>
<th><strong>Specification</strong></th>
<th><strong>Model</strong><br />
<strong>350</strong></th>
<th><strong>Model</strong><br />
<strong>350T</strong></th>
<th><strong>Model</strong><br />
<strong>355</strong></th>
<th><strong>Model</strong><br />
<strong>355T</strong></th>
<th><strong>Model</strong><br />
<strong>350TK</strong></th>
<th><strong>Model</strong><br />
<strong>355TK</strong></th>
<th><strong>Model</strong><br />
<strong>650</strong></th>
<th><strong>Model</strong><br />
<strong>650T</strong></th>
<th><strong>Model</strong><br />
<strong>655</strong></th>
<th><strong>Model</strong><br />
<strong>655T</strong></th>
<th><strong>Model</strong><br />
<strong>550</strong></th>
<th><strong>Model</strong><br />
<strong>555</strong></th>
<th><strong>Model</strong><br />
<strong>330</strong></th>
<th><strong>Model</strong><br />
<strong>335</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td class="col-subject">A</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">10.5 to<br />
less than 11.5</td>
<td>0.15</td>
<td>0.24</td>
<td>0.18</td>
<td>0.27</td>
<td>0.19</td>
<td>0.30</td>
<td>0.07</td>
<td>0.11</td>
<td>0.47</td>
<td>0.14</td>
<td>1.83</td>
<td>1.63</td>
<td>0.26</td>
<td>0.34</td>
</tr>
<tr>
<td class="col-subject">B</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.42</td>
<td>0.32</td>
<td>0.57</td>
<td>0.41</td>
<td>0.36</td>
<td>0.27</td>
<td>0.08</td>
<td>0.20</td>
<td>0.31</td>
<td>0.36</td>
<td>1.29</td>
<td>1.85</td>
<td>0.57</td>
<td>0.13</td>
</tr>
<tr>
<td class="col-subject">C</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.18</td>
<td>0.19</td>
<td>0.25</td>
<td>0.19</td>
<td>0.38</td>
<td>0.36</td>
<td>0.14</td>
<td>0.26</td>
<td>0.16</td>
<td>0.26</td>
<td>1.43</td>
<td>2.45</td>
<td>1.65</td>
<td>0.24</td>
</tr>
<tr>
<td class="col-subject">D</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">10.5 to<br />
less than 11.5</td>
<td>0.35</td>
<td>0.26</td>
<td>0.27</td>
<td>0.24</td>
<td>0.18</td>
<td>0.29</td>
<td>0.11</td>
<td>0.08</td>
<td>0.34</td>
<td>0.25</td>
<td>1.68</td>
<td>1.88</td>
<td>0.73</td>
<td>0.14</td>
</tr>
<tr>
<td class="col-subject">E</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.58</td>
<td>0.44</td>
<td>0.41</td>
<td>0.37</td>
<td>0.42</td>
<td>0.19</td>
<td>0.21</td>
<td>0.72</td>
<td>0.26</td>
<td>0.86</td>
<td>1.74</td>
<td>1.78</td>
<td>1.06</td>
<td>0.13</td>
</tr>
<tr>
<td class="col-subject">F</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.06</td>
<td>0.17</td>
<td>0.09</td>
<td>0.11</td>
<td>0.14</td>
<td>0.48</td>
<td>0.37</td>
<td>0.22</td>
<td>0.38</td>
<td>0.39</td>
<td>1.98</td>
<td>1.37</td>
<td>1.53</td>
<td>0.56</td>
</tr>
<tr>
<td class="col-subject">G</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">13.5 to<br />
less than 14.5</td>
<td>0.09</td>
<td>0.05</td>
<td>0.08</td>
<td>0.12</td>
<td>0.35</td>
<td>0.57</td>
<td>0.11</td>
<td>0.27</td>
<td>0.59</td>
<td>0.70</td>
<td>1.22</td>
<td>1.95</td>
<td>1.33</td>
<td>0.62</td>
</tr>
<tr>
<td class="col-subject">H</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.15</td>
<td>0.07</td>
<td>0.25</td>
<td>0.13</td>
<td>0.12</td>
<td>0.55</td>
<td>0.07</td>
<td>0.19</td>
<td>0.20</td>
<td>0.33</td>
<td>1.35</td>
<td>1.98</td>
<td>2.33</td>
<td>0.32</td>
</tr>
<tr>
<td class="col-subject">I</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.12</td>
<td>0.14</td>
<td>0.15</td>
<td>0.17</td>
<td>0.21</td>
<td>0.44</td>
<td>0.14</td>
<td>0.08</td>
<td>0.41</td>
<td>0.64</td>
<td>1.45</td>
<td>1.78</td>
<td>2.02</td>
<td>0.39</td>
</tr>
<tr>
<td class="col-subject">J</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">13.5 to<br />
less than 14.5</td>
<td>0.41</td>
<td>0.35</td>
<td>0.27</td>
<td>0.19</td>
<td>0.48</td>
<td>0.45</td>
<td>0.39</td>
<td>0.05</td>
<td>0.15</td>
<td>0.20</td>
<td>2.27</td>
<td>2.04</td>
<td>1.76</td>
<td>0.35</td>
</tr>
</tbody>
</table>
</div>
</div>The post <a href="https://koueitrading.com/global/product/koken-hi-luck-355-disposable-dust-mask/">Koken Hi-Luck 355 Disposable Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken Hi-Luck 650-02 Disposable Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-hi-luck-650-02-disposable-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 12 Mar 2020 06:30:08 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192591</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: Hi-Luck 650-02 Important points when wearing a respirator Dust respirators use high-efficiency filters to prevent the inhalation of hazardous dust. To protect yourself from inhaling dust when wearing a dust respirator, the performance of this filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are extremely important. 1. [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-hi-luck-650-02-disposable-dust-mask/">Koken Hi-Luck 650-02 Disposable Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: Hi-Luck 650-02</p>
<h2>Important points when wearing a respirator</h2>
<p>Dust respirators use high-efficiency filters to prevent the inhalation of hazardous dust. To protect yourself from inhaling dust when wearing a dust respirator, the performance of this filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are extremely important.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Through unique technology, the sheep wool is electrostatically charged, and this electrostatic force draws particles to the fiber surface. This is the primary mechanism for collecting particles. A high-density fiber structure is not required, thus integrating the two contrasting features of &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221;</p>
<p>It consistently maintains the highest standard of performance and quality, and has been utilized for a long time as an outstanding filter.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" sizes="auto, (max-width: 317px) 100vw, 317px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png 317w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333-300x204.png 300w" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" sizes="auto, (max-width: 316px) 100vw, 316px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png 316w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322-300x227.png 300w" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applicable products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the filter&#8217;s fiber density improves collection efficiency. To meet airflow resistance standards, paper filters require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into a pristine circular shape in a single process to create the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" sizes="auto, (max-width: 329px) 100vw, 329px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751-300x116.png 300w" alt="" width="329" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" sizes="auto, (max-width: 321px) 100vw, 321px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png 321w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803-300x227.png 300w" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applicable products are from P.8 to P.11</p>
<p data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to national assay standards based on national regulations. The contents of these standards are comprehensive, ensuring the manufacture of products that meet strict safety requirements.</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td width="64">In addition to JIS standards, dust respirators are tested according to national assay standards based on national regulations. The contents of these standards are comprehensive, ensuring the manufacture of products that meet strict safety requirements.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the &#8220;Dust Respirator Standards&#8221;.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Aerosol</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride) particles</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate) particles</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ/min</td>
<td class="text-center" colspan="2">85 ℓ/min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement, must meet the value in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" colspan="2">For NaCl test aerosol<br />
Loaded up to 100mg</td>
<td class="text-left" colspan="2">For DOP test aerosol<br />
Loaded up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or more</td>
<td>RL1</td>
<td class="text-center">80.0% or more</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or more</td>
<td>RL2</td>
<td class="text-center">95.0% or more</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or more</td>
<td>RL3</td>
<td class="text-center">99.9% or more</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or more</td>
<td>DL1</td>
<td class="text-center">80.0% or more</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or more</td>
<td>DL2</td>
<td class="text-center">95.0% or more</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or more</td>
<td>DL3</td>
<td class="text-center">99.9% or more</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>( ) indicates products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col">Exhalation valve operation leak test</td>
<td>&#8211; When air is drawn, the internal pressure must decrease immediately<br />
&#8211; The time for internal pressure to return to normal atmospheric pressure must be 15 seconds or more</td>
</tr>
<tr>
<th class="header-col"><strong>Carbon Dioxide (CO2) Concentration Increase</strong></th>
<td class="content-col" colspan="2">Using a test headform and an artificial lung to inhale/exhale air containing CO2. The difference in CO2 concentration in the inhaled air between wearing and not wearing the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space Volume</strong></th>
<td class="content-col" colspan="2">Calculated from the (Carbon Dioxide Concentration Increase Test)</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Aerosol</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">Measured at 40 ℓ/min after loading test dust at 85 ℓ/min</td>
</tr>
<tr>
<td class="header-sub">Amount loaded onto dust respirator</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Aerosol and Collection Efficiency </span><span class="bottom-left-text">Disposable Type<br />
/ Replaceable Type</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" rowspan="2"><strong>Classification</strong><br />
<strong>(Particle Collection Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender"><strong>Test aerosol is solid Sodium Chloride (NaCl)</strong></th>
<th class="bg-lavender"><strong>Test aerosol is liquid Dioctyl Phthalate (DOP)</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
</tbody>
</table>
<h2>High-Performance Filter + Facepiece Designed for Easy Fit</h2>
<h3>2. Facepiece Fit Technology</h3>
<p>Even if a dust respirator has a high collection efficiency filter, it is meaningless if dust leaks through the face-to-mask seal during use. This is primarily caused by a &#8220;gap at the face contact area when worn.&#8221;</p>
<p>We consider mask fit to be just as important as filter performance. Therefore, our company has long developed technologies to enhance the airtightness of the facepiece seal.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" sizes="auto, (max-width: 247px) 100vw, 247px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg 775w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-227x300.jpg 227w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-768x1015.jpg 768w" alt="" width="247" height="326" /></p>
<p><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and effortlessly adapts to facial movements, ensuring a comfortable fit. The material also remains stable during use.</p>
<p><strong>HAWC Lip Structure</strong><br />
The lip design ensures a high degree of adhesion, maximizing the &#8220;suction cup&#8221; effect when wearing the mask to ensure an airtight facial seal.<img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" sizes="auto, (max-width: 145px) 100vw, 145px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png 319w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014-267x300.png 267w" alt="" width="145" height="163" /></p>
<p><strong>Free Position Under Chin</strong><br />
The unique curve of the face contact area prevents dust from leaking in. By aligning the nose portion first, it accommodates various facial dimensions, providing a secure fit for a wide range of face sizes (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" sizes="auto, (max-width: 192px) 100vw, 192px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png 410w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024-300x180.png 300w" alt="" width="192" height="115" /></p>
<p><strong data-start="56" data-end="112">Fit Status of the Free Position Under Chin Mask</strong><br data-start="112" data-end="115" />(Simulated image with the mask cut away to clearly show where it contacts the chin).</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong data-start="56" data-end="94">For individuals with large faces:</strong><br data-start="94" data-end="97" />The outer section of the mask rests naturally against the chin to provide a proper fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td width="64"><strong data-start="164" data-end="202">For individuals with small faces:</strong><br data-start="202" data-end="205" />The inner section of the mask naturally positions itself against the chin to secure the fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Wearing Stability</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Built-in Fit Checker</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed to naturally conform to various facial sizes and shapes, providing a seamless fit.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Uses a 3D-shaped polyband harness that conforms to the shape of the head, cradling it to enhance fit and sealing performance.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>A built-in fit checker allows you to test the mask&#8217;s seal at any time (available for the 1005, 1010A, 1015, and 1180 series).</td>
</tr>
</tbody>
</table>
<h2 data-start="39" data-end="62"><strong data-start="39" data-end="62">Disposable Dust Respirators</strong></h2>
<p data-start="64" data-end="89"><strong data-start="64" data-end="89">FF Lip (Free Fit Lip)</strong></p>
<p data-start="91" data-end="595">The most important factor when choosing a disposable mask is ensuring a secure fit to the face. The reason the Hi-Luck series provides an excellent fit is that the FF Lip has a shape that easily adapts to various facial sizes and contours.</p>
<p data-start="91" data-end="595">The FF Lip features a wide surface area and a soft design, providing superior sealing capability while easily conforming to facial movements. This prevents seal displacement during use, delivering a natural and tight seal as if the mask were custom-made.</p>
<p data-start="91" data-end="595"><img loading="lazy" decoding="async" class="aligncenter wp-image-56478" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954.png" sizes="auto, (max-width: 254px) 100vw, 254px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954.png 525w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954-300x275.png 300w" alt="" width="254" height="233" /></p>
<p data-start="91" data-end="595"><strong>Three Types of Straps to Choose From</strong></p>
<p data-start="91" data-end="595"><img loading="lazy" decoding="async" class=" wp-image-192566 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-300x79.jpg" alt="" width="569" height="150" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-300x79.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-768x203.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1.jpg 1024w" sizes="auto, (max-width: 569px) 100vw, 569px" /></p>
<p data-start="22" data-end="80"><strong data-start="22" data-end="80">Adjusting the Strap Length for a Perfect Fit</strong></p>
<p data-start="82" data-end="266">To ensure proper mask adhesion, &#8220;adjusting the strap length&#8221; is crucial. If the straps do not fit well or if a gap forms during work, it is unsafe.</p>
<ul>
<li data-start="270" data-end="315">The straps must be positioned correctly for stability.</li>
<li data-start="318" data-end="356">Adjust the length to ensure a snug fit.</li>
</ul>
<p data-start="22" data-end="57"><strong data-start="22" data-end="57">Uses a Synthetic Rubber Strap</strong></p>
<p data-start="59" data-end="154">The strap absorbs moisture well, feels soft against the skin, and prevents allergic reactions associated with natural rubber.</p>
<p data-start="59" data-end="154"><img loading="lazy" decoding="async" class="aligncenter wp-image-56480" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421.png" sizes="auto, (max-width: 195px) 100vw, 195px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421-300x274.png 300w" alt="" width="195" height="178" /></p>
<p data-start="156" data-end="243" data-is-last-node="" data-is-only-node="">The strap length can be adjusted while wearing the mask to accommodate different facial sizes.</p>
<p data-start="22" data-end="62"><strong data-start="22" data-end="62">Easy to Wear &#8211; T-Type (Hook Style)</strong></p>
<ul>
<li data-start="66" data-end="83">Does not tangle hair.</li>
<li data-start="86" data-end="122">Adjustable strap length.</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56481" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505.png" sizes="auto, (max-width: 207px) 100vw, 207px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505.png 312w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505-300x217.png 300w" alt="" width="207" height="150" /></p>
<p data-start="124" data-end="203" data-is-last-node="" data-is-only-node="">Simply pull the strap over the head, wrap it around the sides, and secure it with the hook.</p>
<p data-start="0" data-end="46"><strong data-start="0" data-end="46">Even Softer Wearing Feel (TK Hook Style)</strong></p>
<ul>
<li data-start="50" data-end="67">Does not tangle hair.</li>
<li data-start="70" data-end="121">Adjustable strap length and tension.</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56482" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626.png" sizes="auto, (max-width: 198px) 100vw, 198px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626.png 313w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626-300x219.png 300w" alt="" width="198" height="145" /></p>
<p data-start="123" data-end="225" data-is-last-node="" data-is-only-node="">The tightness of the upper and lower straps can be individually adjusted for an optimal fit, reducing pressure on the ears.</p>
<h2 data-start="123" data-end="225">Hi-Luck Series</h2>
<h3 data-start="55" data-end="92"><strong data-start="55" data-end="90">Information on Hi-Luck 650-02 Respirator</strong></h3>
<p data-start="95" data-end="213">DS2 Standard: Achieves a particle collection efficiency of 95% or higher. Uses an eco-friendly &#8220;Bipromicron&#8221; filter made from recycled filter scrap materials.</p>
<p data-start="95" data-end="213"><img loading="lazy" decoding="async" class="aligncenter wp-image-56494" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-123833.png" alt="" width="251" height="222" /></p>
<ul>
<li data-start="183" data-end="198">FF (Free Fit Lip)</li>
<li data-start="203" data-end="223">Shape Recovery</li>
<li data-start="228" data-end="234">Bipro Filter</li>
</ul>
<p data-start="264" data-end="324"><strong data-start="264" data-end="279">Standard:</strong> Complies with TM597 certification, Assigned Protection Factor of 10.</p>
<h3><strong data-start="61" data-end="80">Bipromicron Filter </strong>(Models 650, 655)</h3>
<p data-start="99" data-end="285">This is a high-performance filter recycled from the leftover raw materials of molded high-efficiency filters. The filter material is repurposed and processed into a new high-performance filter.</p>
<p data-start="287" data-end="456"><strong>Recycled Material</strong><br data-start="307" data-end="310" />We are effectively utilizing waste as a resource. This is an eco-friendly filter created from recycled filter materials.</p>
<p data-start="287" data-end="456"><img loading="lazy" decoding="async" class=" wp-image-192565 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-300x187.jpg" alt="" width="433" height="270" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-300x187.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-768x478.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1.jpg 1024w" sizes="auto, (max-width: 433px) 100vw, 433px" /></p>
<h3 data-start="34" data-end="87"><strong data-start="34" data-end="66">Shape Recovery Structure </strong>(Models 550, 555 excluded)</h3>
<p data-start="89" data-end="274">The inside of the mask is reinforced with a shape-retaining mesh so that it does not lose its form when folded. This ensures the mask maintains its shape even when folded during breaks or short intervals.</p>
<p data-start="276" data-end="289"><strong>Hygiene</strong></p>
<ul>
<li data-start="292" data-end="379">When not in use, you can fold the mask closed to prevent dust from entering the inside of the facepiece.</li>
<li data-start="382" data-end="488">During hot or cold seasons, moisture from breathing may penetrate the mask, but this does not affect its performance.</li>
</ul>
<h3 data-start="34" data-end="162"><strong data-start="34" data-end="63">Completely Incinerable</strong></h3>
<p>The material contains no chloride compounds, so it does not generate toxic gases like dioxins when incinerated.</p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56485" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-113256.png" alt="" width="137" height="164" /></p>
<p><strong data-start="164" data-end="198">Metal-Free Design</strong><br data-start="198" data-end="201" />With the FF Lip design, an excellent seal is achieved without the use of metal parts such as nose clips.</p>
<h3>Features:</h3>
<ul>
<li data-start="36" data-end="124"><strong data-start="36" data-end="42">FF Lip</strong>: The Free Fit Lip design improves airtightness and provides a secure fit to the face.</li>
<li data-start="127" data-end="220"><strong data-start="127" data-end="149">Shape Recovery</strong>: Easily folds away during breaks or transit without losing its structural integrity.</li>
<li data-start="223" data-end="286"><strong data-start="223" data-end="233">Exhalation Valve</strong>: Facilitates easier exhalation and reduces heat buildup.</li>
<li data-start="289" data-end="372"><strong data-start="289" data-end="298">Bipro</strong>: Filter manufactured using recycled materials from ecological sources.</li>
<li data-start="375" data-end="455"><strong data-start="375" data-end="395">Activated Carbon</strong>: Filters out low levels of ozone gas, aiding in air purification.</li>
</ul>
<h3>Performance Specifications</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th class="header-main" colspan="2"><strong>Performance</strong></th>
<th><strong>Model</strong><br />
<strong>350 / 350T</strong></th>
<th><strong>Model</strong><br />
<strong>355 / 355T</strong></th>
<th><strong>Model</strong><br />
<strong>350TK</strong></th>
<th><strong>Model</strong><br />
<strong>355TK</strong></th>
<th><strong>Model</strong><br />
<strong>650 / 650T</strong></th>
<th><strong>Model</strong><br />
<strong>655 / 655T</strong></th>
<th><strong>Model</strong><br />
<strong>550</strong></th>
<th><strong>Model</strong><br />
<strong>555</strong></th>
<th><strong>Model</strong><br />
<strong>330</strong></th>
<th><strong>Model</strong><br />
<strong>335</strong></th>
</tr>
</thead>
<tbody>
<tr>
<th class="row-label" colspan="2"><strong>Particle Collection Efficiency</strong><br />
<strong><span class="small-text">(NaCl particles)</span></strong></th>
<td>95.0% or more<br />
(98.4%)</td>
<td>95.0% or more<br />
(97.9%)</td>
<td>95.0% or more<br />
(98.31%)</td>
<td>95.0% or more<br />
(98.18%)</td>
<td>95.0% or more<br />
(99.4%)</td>
<td>95.0% or more<br />
(99.0%)</td>
<td>80.0% or more<br />
(89.3%)</td>
<td>80.0% or more<br />
(88.6%)</td>
<td>80.0% or more<br />
(89.73%)</td>
<td>95.0% or more<br />
(98.46%)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Inhalation Resistance</strong></th>
<td>50Pa or less<br />
(35Pa)</td>
<td>50Pa or less<br />
(37Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>50Pa or less<br />
(39Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>52Pa or less<br />
(40Pa)</td>
<td>40Pa or less<br />
(29Pa)</td>
<td>43Pa or less<br />
(32Pa)</td>
<td>45Pa or less<br />
(28Pa)</td>
<td>70Pa or less<br />
(50Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Exhalation Resistance</strong></th>
<td>50Pa or less<br />
(35Pa)</td>
<td>36Pa or less<br />
(21Pa)</td>
<td>50Pa or less<br />
(35Pa)</td>
<td>36Pa or less<br />
(21Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>36Pa or less<br />
(19Pa)</td>
<td>40Pa or less<br />
(29Pa)</td>
<td>28Pa or less<br />
(18Pa)</td>
<td>45Pa or less<br />
(29Pa)</td>
<td>40Pa or less<br />
(22Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Inhalation Resistance Increase</strong></th>
<td>―<br />
(135Pa)</td>
<td>―<br />
(203Pa)</td>
<td>―<br />
(131Pa)</td>
<td>―<br />
(160Pa)</td>
<td>―<br />
(90Pa)</td>
<td>―<br />
(113Pa)</td>
<td>―<br />
(97Pa)</td>
<td>―<br />
(147Pa)</td>
<td>―<br />
(122Pa)</td>
<td>―<br />
(208Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>CO2 Concentration Increase</strong><br />
<strong>/ Dead Space</strong></th>
<td>1.0% or less / 400cm³ or less<br />
(0.45% / 178cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.41% / 165cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.42% / 166cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.39% / 156cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.37% / 149cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.39% / 156cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.73% / 293cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.71% / 283cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.38% / 152cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.34% / 136cm³)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Wet Resistance Value</strong></th>
<td>―<br />
(31Pa)</td>
<td>―<br />
(22Pa)</td>
<td>―<br />
(29Pa)</td>
<td>―<br />
(18Pa)</td>
<td>―<br />
(30Pa)</td>
<td>―<br />
(17Pa)</td>
<td>―<br />
(25Pa)</td>
<td>―<br />
(16Pa)</td>
<td>―<br />
(24Pa)</td>
<td>―<br />
(18Pa)</td>
</tr>
<tr>
<th class="row-label" rowspan="3"><strong>Weight</strong></th>
<th class="row-label"><strong>2-Strap Type</strong></th>
<td>Model 350: 12.1g or less<br />
(9.1g)</td>
<td>Model 355: 14.1g or less<br />
(11.1g)</td>
<td>―</td>
<td>―</td>
<td>Model 650: 12.6g or less<br />
(9.9g)</td>
<td>Model 655: 14.5g or less<br />
(11.8g)</td>
<td>12.3g or less (10.1g)</td>
<td>14.1g or less (11.8g)</td>
<td>―</td>
<td>―</td>
</tr>
<tr>
<th class="row-label"><strong>Hook Type</strong></th>
<td>Model 350T: 12.7g or less<br />
(9.7g)</td>
<td>Model 355T: 14.5g or less<br />
(11.5g)</td>
<td>―</td>
<td>―</td>
<td>Model 650T: 13.1g or less<br />
(10.2g)</td>
<td>Model 655T: 15.0g or less<br />
(12.4g)</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>―</td>
</tr>
<tr>
<th class="row-label"><strong>TK Hook Type</strong></th>
<td>―</td>
<td>―</td>
<td>13.3g or less<br />
(10.4g)</td>
<td>15.3g or less<br />
(12.3g)</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>12.5g or less<br />
(9.9g)</td>
<td>14.5g or less<br />
(11.7g)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Maximum Use Time Limit</strong></th>
<td>13 Hours</td>
<td>15 Hours</td>
<td>13 Hours</td>
<td>15 Hours</td>
<td>20 Hours</td>
<td>25 Hours</td>
<td>12 Hours</td>
<td>13 Hours</td>
<td>10 Hours</td>
<td>8 Hours</td>
</tr>
</tbody>
</table>
<p>Models 350TK, 355TK, 330, and 335 use the TK hook type strap. Models 350T, 355T, 650T, and 655T use the standard hook type strap.<br />
Values in ( ) indicate average values.</p>
<h3 data-start="34" data-end="59"><strong data-start="34" data-end="59">Regarding usage time:</strong></h3>
<p data-start="62" data-end="200">When using a disposable respirator, the maximum use time is specified according to the standards of the Japanese Society of Respiratory Protection Engineers.<br />
When supplied with 0.1g NaCl / minute at an airflow of 40L/minute, the usage time of this respirator will meet the Japanese national standard for dust respirators, until it exceeds 1.5 times the specified value.</p>
<p data-start="62" data-end="200">However, you must replace the mask in the following situations:</p>
<ul>
<li data-start="480" data-end="501">When breathing becomes difficult.</li>
<li data-start="506" data-end="537">When the mask is damaged or heavily soiled.</li>
<li data-start="542" data-end="566">When the mask becomes deformed.</li>
</ul>
<h3 class="table-title">Inward Leakage Rate</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th class="col-subject" rowspan="2"><strong>Test</strong><br />
<strong>Subject</strong></th>
<th><strong>Lip Width (cm)</strong></th>
<th><strong>Nose-Chin Distance (cm)</strong></th>
<th colspan="14"><strong>Leakage Rate (%)</strong></th>
</tr>
<tr>
<th><strong>Specification</strong></th>
<th><strong>Specification</strong></th>
<th><strong>Model</strong><br />
<strong>350</strong></th>
<th><strong>Model</strong><br />
<strong>350T</strong></th>
<th><strong>Model</strong><br />
<strong>355</strong></th>
<th><strong>Model</strong><br />
<strong>355T</strong></th>
<th><strong>Model</strong><br />
<strong>350TK</strong></th>
<th><strong>Model</strong><br />
<strong>355TK</strong></th>
<th><strong>Model</strong><br />
<strong>650</strong></th>
<th><strong>Model</strong><br />
<strong>650T</strong></th>
<th><strong>Model</strong><br />
<strong>655</strong></th>
<th><strong>Model</strong><br />
<strong>655T</strong></th>
<th><strong>Model</strong><br />
<strong>550</strong></th>
<th><strong>Model</strong><br />
<strong>555</strong></th>
<th><strong>Model</strong><br />
<strong>330</strong></th>
<th><strong>Model</strong><br />
<strong>335</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td class="col-subject">A</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">10.5 to<br />
less than 11.5</td>
<td>0.15</td>
<td>0.24</td>
<td>0.18</td>
<td>0.27</td>
<td>0.19</td>
<td>0.30</td>
<td>0.07</td>
<td>0.11</td>
<td>0.47</td>
<td>0.14</td>
<td>1.83</td>
<td>1.63</td>
<td>0.26</td>
<td>0.34</td>
</tr>
<tr>
<td class="col-subject">B</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.42</td>
<td>0.32</td>
<td>0.57</td>
<td>0.41</td>
<td>0.36</td>
<td>0.27</td>
<td>0.08</td>
<td>0.20</td>
<td>0.31</td>
<td>0.36</td>
<td>1.29</td>
<td>1.85</td>
<td>0.57</td>
<td>0.13</td>
</tr>
<tr>
<td class="col-subject">C</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.18</td>
<td>0.19</td>
<td>0.25</td>
<td>0.19</td>
<td>0.38</td>
<td>0.36</td>
<td>0.14</td>
<td>0.26</td>
<td>0.16</td>
<td>0.26</td>
<td>1.43</td>
<td>2.45</td>
<td>1.65</td>
<td>0.24</td>
</tr>
<tr>
<td class="col-subject">D</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">10.5 to<br />
less than 11.5</td>
<td>0.35</td>
<td>0.26</td>
<td>0.27</td>
<td>0.24</td>
<td>0.18</td>
<td>0.29</td>
<td>0.11</td>
<td>0.08</td>
<td>0.34</td>
<td>0.25</td>
<td>1.68</td>
<td>1.88</td>
<td>0.73</td>
<td>0.14</td>
</tr>
<tr>
<td class="col-subject">E</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.58</td>
<td>0.44</td>
<td>0.41</td>
<td>0.37</td>
<td>0.42</td>
<td>0.19</td>
<td>0.21</td>
<td>0.72</td>
<td>0.26</td>
<td>0.86</td>
<td>1.74</td>
<td>1.78</td>
<td>1.06</td>
<td>0.13</td>
</tr>
<tr>
<td class="col-subject">F</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.06</td>
<td>0.17</td>
<td>0.09</td>
<td>0.11</td>
<td>0.14</td>
<td>0.48</td>
<td>0.37</td>
<td>0.22</td>
<td>0.38</td>
<td>0.39</td>
<td>1.98</td>
<td>1.37</td>
<td>1.53</td>
<td>0.56</td>
</tr>
<tr>
<td class="col-subject">G</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">13.5 to<br />
less than 14.5</td>
<td>0.09</td>
<td>0.05</td>
<td>0.08</td>
<td>0.12</td>
<td>0.35</td>
<td>0.57</td>
<td>0.11</td>
<td>0.27</td>
<td>0.59</td>
<td>0.70</td>
<td>1.22</td>
<td>1.95</td>
<td>1.33</td>
<td>0.62</td>
</tr>
<tr>
<td class="col-subject">H</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.15</td>
<td>0.07</td>
<td>0.25</td>
<td>0.13</td>
<td>0.12</td>
<td>0.55</td>
<td>0.07</td>
<td>0.19</td>
<td>0.20</td>
<td>0.33</td>
<td>1.35</td>
<td>1.98</td>
<td>2.33</td>
<td>0.32</td>
</tr>
<tr>
<td class="col-subject">I</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.12</td>
<td>0.14</td>
<td>0.15</td>
<td>0.17</td>
<td>0.21</td>
<td>0.44</td>
<td>0.14</td>
<td>0.08</td>
<td>0.41</td>
<td>0.64</td>
<td>1.45</td>
<td>1.78</td>
<td>2.02</td>
<td>0.39</td>
</tr>
<tr>
<td class="col-subject">J</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">13.5 to<br />
less than 14.5</td>
<td>0.41</td>
<td>0.35</td>
<td>0.27</td>
<td>0.19</td>
<td>0.48</td>
<td>0.45</td>
<td>0.39</td>
<td>0.05</td>
<td>0.15</td>
<td>0.20</td>
<td>2.27</td>
<td>2.04</td>
<td>1.76</td>
<td>0.35</td>
</tr>
</tbody>
</table>
</div>
</div>The post <a href="https://koueitrading.com/global/product/koken-hi-luck-650-02-disposable-dust-mask/">Koken Hi-Luck 650-02 Disposable Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken Hi-Luck 655-02 Disposable Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-hi-luck-655-02-disposable-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 12 Mar 2020 06:16:44 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192589</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: Hi-Luck 655-02 Important points when wearing a respirator Dust respirators use high-efficiency filters to prevent the inhalation of hazardous dust. To protect yourself from inhaling dust when wearing a dust respirator, the performance of this filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are extremely important. 1. [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-hi-luck-655-02-disposable-dust-mask/">Koken Hi-Luck 655-02 Disposable Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: Hi-Luck 655-02</p>
<h2>Important points when wearing a respirator</h2>
<p>Dust respirators use high-efficiency filters to prevent the inhalation of hazardous dust. To protect yourself from inhaling dust when wearing a dust respirator, the performance of this filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are extremely important.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Through unique technology, the sheep wool is electrostatically charged, and this electrostatic force draws particles to the fiber surface. This is the primary mechanism for collecting particles. A high-density fiber structure is not required, thus integrating the two contrasting features of &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221;</p>
<p>It consistently maintains the highest standard of performance and quality, and has been utilized for a long time as an outstanding filter.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" sizes="auto, (max-width: 317px) 100vw, 317px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png 317w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333-300x204.png 300w" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" sizes="auto, (max-width: 316px) 100vw, 316px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png 316w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322-300x227.png 300w" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applicable products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the filter&#8217;s fiber density improves collection efficiency. To meet airflow resistance standards, paper filters require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into a pristine circular shape in a single process to create the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" sizes="auto, (max-width: 329px) 100vw, 329px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751-300x116.png 300w" alt="" width="329" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" sizes="auto, (max-width: 321px) 100vw, 321px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png 321w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803-300x227.png 300w" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applicable products are from P.8 to P.11</p>
<p data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to national assay standards based on national regulations. The contents of these standards are comprehensive, ensuring the manufacture of products that meet strict safety requirements.</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td width="64">In addition to JIS standards, dust respirators are tested according to national assay standards based on national regulations. The contents of these standards are comprehensive, ensuring the manufacture of products that meet strict safety requirements.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the &#8220;Dust Respirator Standards&#8221;.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Aerosol</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride) particles</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate) particles</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ/min</td>
<td class="text-center" colspan="2">85 ℓ/min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement, must meet the value in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" colspan="2">For NaCl test aerosol<br />
Loaded up to 100mg</td>
<td class="text-left" colspan="2">For DOP test aerosol<br />
Loaded up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or more</td>
<td>RL1</td>
<td class="text-center">80.0% or more</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or more</td>
<td>RL2</td>
<td class="text-center">95.0% or more</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or more</td>
<td>RL3</td>
<td class="text-center">99.9% or more</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or more</td>
<td>DL1</td>
<td class="text-center">80.0% or more</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or more</td>
<td>DL2</td>
<td class="text-center">95.0% or more</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or more</td>
<td>DL3</td>
<td class="text-center">99.9% or more</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>( ) indicates products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col">Exhalation valve operation leak test</td>
<td>&#8211; When air is drawn, the internal pressure must decrease immediately<br />
&#8211; The time for internal pressure to return to normal atmospheric pressure must be 15 seconds or more</td>
</tr>
<tr>
<th class="header-col"><strong>Carbon Dioxide (CO2) Concentration Increase</strong></th>
<td class="content-col" colspan="2">Using a test headform and an artificial lung to inhale/exhale air containing CO2. The difference in CO2 concentration in the inhaled air between wearing and not wearing the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space Volume</strong></th>
<td class="content-col" colspan="2">Calculated from the (Carbon Dioxide Concentration Increase Test)</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Aerosol</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">Measured at 40 ℓ/min after loading test dust at 85 ℓ/min</td>
</tr>
<tr>
<td class="header-sub">Amount loaded onto dust respirator</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Aerosol and Collection Efficiency </span><span class="bottom-left-text">Disposable Type<br />
/ Replaceable Type</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" rowspan="2"><strong>Classification</strong><br />
<strong>(Particle Collection Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender"><strong>Test aerosol is solid Sodium Chloride (NaCl)</strong></th>
<th class="bg-lavender"><strong>Test aerosol is liquid Dioctyl Phthalate (DOP)</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
</tbody>
</table>
<h2>High-Performance Filter + Facepiece Designed for Easy Fit</h2>
<h3>2. Facepiece Fit Technology</h3>
<p>Even if a dust respirator has a high collection efficiency filter, it is meaningless if dust leaks through the face-to-mask seal during use. This is primarily caused by a &#8220;gap at the face contact area when worn.&#8221;</p>
<p>We consider mask fit to be just as important as filter performance. Therefore, our company has long developed technologies to enhance the airtightness of the facepiece seal.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" sizes="auto, (max-width: 247px) 100vw, 247px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg 775w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-227x300.jpg 227w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-768x1015.jpg 768w" alt="" width="247" height="326" /></p>
<p><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and effortlessly adapts to facial movements, ensuring a comfortable fit. The material also remains stable during use.</p>
<p><strong>HAWC Lip Structure</strong><br />
The lip design ensures a high degree of adhesion, maximizing the &#8220;suction cup&#8221; effect when wearing the mask to ensure an airtight facial seal.<img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" sizes="auto, (max-width: 145px) 100vw, 145px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png 319w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014-267x300.png 267w" alt="" width="145" height="163" /></p>
<p><strong>Free Position Under Chin</strong><br />
The unique curve of the face contact area prevents dust from leaking in. By aligning the nose portion first, it accommodates various facial dimensions, providing a secure fit for a wide range of face sizes (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" sizes="auto, (max-width: 192px) 100vw, 192px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png 410w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024-300x180.png 300w" alt="" width="192" height="115" /></p>
<p><strong data-start="56" data-end="112">Fit Status of the Free Position Under Chin Mask</strong><br data-start="112" data-end="115" />(Simulated image with the mask cut away to clearly show where it contacts the chin).</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong data-start="56" data-end="94">For individuals with large faces:</strong><br data-start="94" data-end="97" />The outer section of the mask rests naturally against the chin to provide a proper fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td width="64"><strong data-start="164" data-end="202">For individuals with small faces:</strong><br data-start="202" data-end="205" />The inner section of the mask naturally positions itself against the chin to secure the fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Wearing Stability</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Built-in Fit Checker</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed to naturally conform to various facial sizes and shapes, providing a seamless fit.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Uses a 3D-shaped polyband harness that conforms to the shape of the head, cradling it to enhance fit and sealing performance.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>A built-in fit checker allows you to test the mask&#8217;s seal at any time (available for the 1005, 1010A, 1015, and 1180 series).</td>
</tr>
</tbody>
</table>
<h2 data-start="39" data-end="62"><strong data-start="39" data-end="62">Disposable Dust Respirators</strong></h2>
<p data-start="64" data-end="89"><strong data-start="64" data-end="89">FF Lip (Free Fit Lip)</strong></p>
<p data-start="91" data-end="595">The most important factor when choosing a disposable mask is ensuring a secure fit to the face. The reason the Hi-Luck series provides an excellent fit is that the FF Lip has a shape that easily adapts to various facial sizes and contours.</p>
<p data-start="91" data-end="595">The FF Lip features a wide surface area and a soft design, providing superior sealing capability while easily conforming to facial movements. This prevents seal displacement during use, delivering a natural and tight seal as if the mask were custom-made.</p>
<p data-start="91" data-end="595"><img loading="lazy" decoding="async" class="aligncenter wp-image-56478" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954.png" sizes="auto, (max-width: 254px) 100vw, 254px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954.png 525w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954-300x275.png 300w" alt="" width="254" height="233" /></p>
<p data-start="91" data-end="595"><strong>Three Types of Straps to Choose From</strong></p>
<p data-start="91" data-end="595"><img loading="lazy" decoding="async" class=" wp-image-192566 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-300x79.jpg" alt="" width="524" height="138" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-300x79.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-768x203.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1.jpg 1024w" sizes="auto, (max-width: 524px) 100vw, 524px" /></p>
<p data-start="22" data-end="80"><strong data-start="22" data-end="80">Adjusting the Strap Length for a Perfect Fit</strong></p>
<p data-start="82" data-end="266">To ensure proper mask adhesion, &#8220;adjusting the strap length&#8221; is crucial. If the straps do not fit well or if a gap forms during work, it is unsafe.</p>
<ul>
<li data-start="270" data-end="315">The straps must be positioned correctly for stability.</li>
<li data-start="318" data-end="356">Adjust the length to ensure a snug fit.</li>
</ul>
<p data-start="22" data-end="57"><strong data-start="22" data-end="57">Uses a Synthetic Rubber Strap</strong></p>
<p data-start="59" data-end="154">The strap absorbs moisture well, feels soft against the skin, and prevents allergic reactions associated with natural rubber.</p>
<p data-start="59" data-end="154"><img loading="lazy" decoding="async" class="aligncenter wp-image-56480" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421.png" sizes="auto, (max-width: 195px) 100vw, 195px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421-300x274.png 300w" alt="" width="195" height="178" /></p>
<p data-start="156" data-end="243" data-is-last-node="" data-is-only-node="">The strap length can be adjusted while wearing the mask to accommodate different facial sizes.</p>
<p data-start="22" data-end="62"><strong data-start="22" data-end="62">Easy to Wear &#8211; T-Type (Hook Style)</strong></p>
<ul>
<li data-start="66" data-end="83">Does not tangle hair.</li>
<li data-start="86" data-end="122">Adjustable strap length.</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56481" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505.png" sizes="auto, (max-width: 207px) 100vw, 207px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505.png 312w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505-300x217.png 300w" alt="" width="207" height="150" /></p>
<p data-start="124" data-end="203" data-is-last-node="" data-is-only-node="">Simply pull the strap over the head, wrap it around the sides, and secure it with the hook.</p>
<p data-start="0" data-end="46"><strong data-start="0" data-end="46">Even Softer Wearing Feel (TK Hook Style)</strong></p>
<ul>
<li data-start="50" data-end="67">Does not tangle hair.</li>
<li data-start="70" data-end="121">Adjustable strap length and tension.</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56482" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626.png" sizes="auto, (max-width: 198px) 100vw, 198px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626.png 313w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626-300x219.png 300w" alt="" width="198" height="145" /></p>
<p data-start="123" data-end="225" data-is-last-node="" data-is-only-node="">The tightness of the upper and lower straps can be individually adjusted for an optimal fit, reducing pressure on the ears.</p>
<h2 data-start="123" data-end="225">Hi-Luck Series</h2>
<h3 data-start="59" data-end="94"><strong data-start="59" data-end="94">Information on Hi-Luck 655-02 Respirator</strong></h3>
<p data-start="98" data-end="147">DS2 Standard: Achieves a filtration efficiency of 95% or higher. Equipped with an exhalation valve design. This minimizes breathing condensation inside the mask and makes the inhalation/exhalation process easier.</p>
<p data-start="98" data-end="147"><img loading="lazy" decoding="async" class="wp-image-56498 aligncenter" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-125112.png" alt="" width="234" height="217" /></p>
<ul>
<li data-start="50" data-end="80">FF (Free Fit Lip)</li>
<li data-start="83" data-end="134">Shape Recovery</li>
<li data-start="137" data-end="183">Exhalation Valve</li>
<li data-start="186" data-end="213">Bipro Filter</li>
</ul>
<p><strong data-start="325" data-end="340">Standard:</strong> Complies with TM598 certification, Assigned Protection Factor of 10.</p>
<h3><strong data-start="61" data-end="80">Bipromicron Filter </strong>(Models 650, 655)</h3>
<p data-start="99" data-end="285">This is a high-performance filter recycled from the leftover raw materials of molded high-efficiency filters. The filter material is repurposed and processed into a new high-performance filter.</p>
<p data-start="287" data-end="456"><strong>Recycled Material</strong><br data-start="307" data-end="310" />We are effectively utilizing waste as a resource. This is an eco-friendly filter created from recycled filter materials.</p>
<p data-start="287" data-end="456"><img loading="lazy" decoding="async" class=" wp-image-192565 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-300x187.jpg" alt="" width="475" height="296" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-300x187.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-768x478.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1.jpg 1024w" sizes="auto, (max-width: 475px) 100vw, 475px" /></p>
<h3 data-start="34" data-end="87"><strong data-start="34" data-end="66">Shape Recovery Structure </strong>(Models 550, 555 excluded)</h3>
<p data-start="89" data-end="274">The inside of the mask is reinforced with a shape-retaining mesh so that it does not lose its form when folded. This ensures the mask maintains its shape even when folded during breaks or short intervals.</p>
<p data-start="276" data-end="289"><strong>Hygiene</strong></p>
<ul>
<li data-start="292" data-end="379">When not in use, you can fold the mask closed to prevent dust from entering the inside of the facepiece.</li>
<li data-start="382" data-end="488">During hot or cold seasons, moisture from breathing may penetrate the mask, but this does not affect its performance.</li>
</ul>
<h3 data-start="34" data-end="162"><strong data-start="34" data-end="63">Completely Incinerable</strong></h3>
<p>The material contains no chloride compounds, so it does not generate toxic gases like dioxins when incinerated.</p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56485" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-113256.png" alt="" width="137" height="164" /></p>
<p><strong data-start="164" data-end="198">Metal-Free Design</strong><br data-start="198" data-end="201" />With the FF Lip design, an excellent seal is achieved without the use of metal parts such as nose clips.</p>
<h3>Features:</h3>
<ul>
<li data-start="36" data-end="124"><strong data-start="36" data-end="42">FF Lip</strong>: The Free Fit Lip design improves airtightness and provides a secure fit to the face.</li>
<li data-start="127" data-end="220"><strong data-start="127" data-end="149">Shape Recovery</strong>: Easily folds away during breaks or transit without losing its structural integrity.</li>
<li data-start="223" data-end="286"><strong data-start="223" data-end="233">Exhalation Valve</strong>: Facilitates easier exhalation and reduces heat buildup.</li>
<li data-start="289" data-end="372"><strong data-start="289" data-end="298">Bipro</strong>: Filter manufactured using recycled materials from ecological sources.</li>
<li data-start="375" data-end="455"><strong data-start="375" data-end="395">Activated Carbon</strong>: Filters out low levels of ozone gas, aiding in air purification.</li>
</ul>
<h3>Performance Specifications</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th class="header-main" colspan="2"><strong>Performance</strong></th>
<th><strong>Model</strong><br />
<strong>350 / 350T</strong></th>
<th><strong>Model</strong><br />
<strong>355 / 355T</strong></th>
<th><strong>Model</strong><br />
<strong>350TK</strong></th>
<th><strong>Model</strong><br />
<strong>355TK</strong></th>
<th><strong>Model</strong><br />
<strong>650 / 650T</strong></th>
<th><strong>Model</strong><br />
<strong>655 / 655T</strong></th>
<th><strong>Model</strong><br />
<strong>550</strong></th>
<th><strong>Model</strong><br />
<strong>555</strong></th>
<th><strong>Model</strong><br />
<strong>330</strong></th>
<th><strong>Model</strong><br />
<strong>335</strong></th>
</tr>
</thead>
<tbody>
<tr>
<th class="row-label" colspan="2"><strong>Particle Collection Efficiency</strong><br />
<strong><span class="small-text">(NaCl particles)</span></strong></th>
<td>95.0% or more<br />
(98.4%)</td>
<td>95.0% or more<br />
(97.9%)</td>
<td>95.0% or more<br />
(98.31%)</td>
<td>95.0% or more<br />
(98.18%)</td>
<td>95.0% or more<br />
(99.4%)</td>
<td>95.0% or more<br />
(99.0%)</td>
<td>80.0% or more<br />
(89.3%)</td>
<td>80.0% or more<br />
(88.6%)</td>
<td>80.0% or more<br />
(89.73%)</td>
<td>95.0% or more<br />
(98.46%)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Inhalation Resistance</strong></th>
<td>50Pa or less<br />
(35Pa)</td>
<td>50Pa or less<br />
(37Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>50Pa or less<br />
(39Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>52Pa or less<br />
(40Pa)</td>
<td>40Pa or less<br />
(29Pa)</td>
<td>43Pa or less<br />
(32Pa)</td>
<td>45Pa or less<br />
(28Pa)</td>
<td>70Pa or less<br />
(50Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Exhalation Resistance</strong></th>
<td>50Pa or less<br />
(35Pa)</td>
<td>36Pa or less<br />
(21Pa)</td>
<td>50Pa or less<br />
(35Pa)</td>
<td>36Pa or less<br />
(21Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>36Pa or less<br />
(19Pa)</td>
<td>40Pa or less<br />
(29Pa)</td>
<td>28Pa or less<br />
(18Pa)</td>
<td>45Pa or less<br />
(29Pa)</td>
<td>40Pa or less<br />
(22Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Inhalation Resistance Increase</strong></th>
<td>―<br />
(135Pa)</td>
<td>―<br />
(203Pa)</td>
<td>―<br />
(131Pa)</td>
<td>―<br />
(160Pa)</td>
<td>―<br />
(90Pa)</td>
<td>―<br />
(113Pa)</td>
<td>―<br />
(97Pa)</td>
<td>―<br />
(147Pa)</td>
<td>―<br />
(122Pa)</td>
<td>―<br />
(208Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>CO2 Concentration Increase</strong><br />
<strong>/ Dead Space</strong></th>
<td>1.0% or less / 400cm³ or less<br />
(0.45% / 178cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.41% / 165cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.42% / 166cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.39% / 156cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.37% / 149cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.39% / 156cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.73% / 293cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.71% / 283cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.38% / 152cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.34% / 136cm³)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Wet Resistance Value</strong></th>
<td>―<br />
(31Pa)</td>
<td>―<br />
(22Pa)</td>
<td>―<br />
(29Pa)</td>
<td>―<br />
(18Pa)</td>
<td>―<br />
(30Pa)</td>
<td>―<br />
(17Pa)</td>
<td>―<br />
(25Pa)</td>
<td>―<br />
(16Pa)</td>
<td>―<br />
(24Pa)</td>
<td>―<br />
(18Pa)</td>
</tr>
<tr>
<th class="row-label" rowspan="3"><strong>Weight</strong></th>
<th class="row-label"><strong>2-Strap Type</strong></th>
<td>Model 350: 12.1g or less<br />
(9.1g)</td>
<td>Model 355: 14.1g or less<br />
(11.1g)</td>
<td>―</td>
<td>―</td>
<td>Model 650: 12.6g or less<br />
(9.9g)</td>
<td>Model 655: 14.5g or less<br />
(11.8g)</td>
<td>12.3g or less (10.1g)</td>
<td>14.1g or less (11.8g)</td>
<td>―</td>
<td>―</td>
</tr>
<tr>
<th class="row-label"><strong>Hook Type</strong></th>
<td>Model 350T: 12.7g or less<br />
(9.7g)</td>
<td>Model 355T: 14.5g or less<br />
(11.5g)</td>
<td>―</td>
<td>―</td>
<td>Model 650T: 13.1g or less<br />
(10.2g)</td>
<td>Model 655T: 15.0g or less<br />
(12.4g)</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>―</td>
</tr>
<tr>
<th class="row-label"><strong>TK Hook Type</strong></th>
<td>―</td>
<td>―</td>
<td>13.3g or less<br />
(10.4g)</td>
<td>15.3g or less<br />
(12.3g)</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>12.5g or less<br />
(9.9g)</td>
<td>14.5g or less<br />
(11.7g)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Maximum Use Time Limit</strong></th>
<td>13 Hours</td>
<td>15 Hours</td>
<td>13 Hours</td>
<td>15 Hours</td>
<td>20 Hours</td>
<td>25 Hours</td>
<td>12 Hours</td>
<td>13 Hours</td>
<td>10 Hours</td>
<td>8 Hours</td>
</tr>
</tbody>
</table>
<p>Models 350TK, 355TK, 330, and 335 use the TK hook type strap. Models 350T, 355T, 650T, and 655T use the standard hook type strap.<br />
Values in ( ) indicate average values.</p>
<h3 data-start="34" data-end="59"><strong data-start="34" data-end="59">Regarding usage time:</strong></h3>
<p data-start="62" data-end="200">When using a disposable respirator, the maximum use time is specified according to the standards of the Japanese Society of Respiratory Protection Engineers.<br />
When supplied with 0.1g NaCl / minute at an airflow of 40L/minute, the usage time of this respirator will meet the Japanese national standard for dust respirators, until it exceeds 1.5 times the specified value.</p>
<p data-start="62" data-end="200">However, you must replace the mask in the following situations:</p>
<ul>
<li data-start="480" data-end="501">When breathing becomes difficult.</li>
<li data-start="506" data-end="537">When the mask is damaged or heavily soiled.</li>
<li data-start="542" data-end="566">When the mask becomes deformed.</li>
</ul>
<h3 class="table-title">Inward Leakage Rate</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th class="col-subject" rowspan="2"><strong>Test</strong><br />
<strong>Subject</strong></th>
<th><strong>Lip Width (cm)</strong></th>
<th><strong>Nose-Chin Distance (cm)</strong></th>
<th colspan="14"><strong>Leakage Rate (%)</strong></th>
</tr>
<tr>
<th><strong>Specification</strong></th>
<th><strong>Specification</strong></th>
<th><strong>Model</strong><br />
<strong>350</strong></th>
<th><strong>Model</strong><br />
<strong>350T</strong></th>
<th><strong>Model</strong><br />
<strong>355</strong></th>
<th><strong>Model</strong><br />
<strong>355T</strong></th>
<th><strong>Model</strong><br />
<strong>350TK</strong></th>
<th><strong>Model</strong><br />
<strong>355TK</strong></th>
<th><strong>Model</strong><br />
<strong>650</strong></th>
<th><strong>Model</strong><br />
<strong>650T</strong></th>
<th><strong>Model</strong><br />
<strong>655</strong></th>
<th><strong>Model</strong><br />
<strong>655T</strong></th>
<th><strong>Model</strong><br />
<strong>550</strong></th>
<th><strong>Model</strong><br />
<strong>555</strong></th>
<th><strong>Model</strong><br />
<strong>330</strong></th>
<th><strong>Model</strong><br />
<strong>335</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td class="col-subject">A</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">10.5 to<br />
less than 11.5</td>
<td>0.15</td>
<td>0.24</td>
<td>0.18</td>
<td>0.27</td>
<td>0.19</td>
<td>0.30</td>
<td>0.07</td>
<td>0.11</td>
<td>0.47</td>
<td>0.14</td>
<td>1.83</td>
<td>1.63</td>
<td>0.26</td>
<td>0.34</td>
</tr>
<tr>
<td class="col-subject">B</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.42</td>
<td>0.32</td>
<td>0.57</td>
<td>0.41</td>
<td>0.36</td>
<td>0.27</td>
<td>0.08</td>
<td>0.20</td>
<td>0.31</td>
<td>0.36</td>
<td>1.29</td>
<td>1.85</td>
<td>0.57</td>
<td>0.13</td>
</tr>
<tr>
<td class="col-subject">C</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.18</td>
<td>0.19</td>
<td>0.25</td>
<td>0.19</td>
<td>0.38</td>
<td>0.36</td>
<td>0.14</td>
<td>0.26</td>
<td>0.16</td>
<td>0.26</td>
<td>1.43</td>
<td>2.45</td>
<td>1.65</td>
<td>0.24</td>
</tr>
<tr>
<td class="col-subject">D</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">10.5 to<br />
less than 11.5</td>
<td>0.35</td>
<td>0.26</td>
<td>0.27</td>
<td>0.24</td>
<td>0.18</td>
<td>0.29</td>
<td>0.11</td>
<td>0.08</td>
<td>0.34</td>
<td>0.25</td>
<td>1.68</td>
<td>1.88</td>
<td>0.73</td>
<td>0.14</td>
</tr>
<tr>
<td class="col-subject">E</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.58</td>
<td>0.44</td>
<td>0.41</td>
<td>0.37</td>
<td>0.42</td>
<td>0.19</td>
<td>0.21</td>
<td>0.72</td>
<td>0.26</td>
<td>0.86</td>
<td>1.74</td>
<td>1.78</td>
<td>1.06</td>
<td>0.13</td>
</tr>
<tr>
<td class="col-subject">F</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.06</td>
<td>0.17</td>
<td>0.09</td>
<td>0.11</td>
<td>0.14</td>
<td>0.48</td>
<td>0.37</td>
<td>0.22</td>
<td>0.38</td>
<td>0.39</td>
<td>1.98</td>
<td>1.37</td>
<td>1.53</td>
<td>0.56</td>
</tr>
<tr>
<td class="col-subject">G</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">13.5 to<br />
less than 14.5</td>
<td>0.09</td>
<td>0.05</td>
<td>0.08</td>
<td>0.12</td>
<td>0.35</td>
<td>0.57</td>
<td>0.11</td>
<td>0.27</td>
<td>0.59</td>
<td>0.70</td>
<td>1.22</td>
<td>1.95</td>
<td>1.33</td>
<td>0.62</td>
</tr>
<tr>
<td class="col-subject">H</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.15</td>
<td>0.07</td>
<td>0.25</td>
<td>0.13</td>
<td>0.12</td>
<td>0.55</td>
<td>0.07</td>
<td>0.19</td>
<td>0.20</td>
<td>0.33</td>
<td>1.35</td>
<td>1.98</td>
<td>2.33</td>
<td>0.32</td>
</tr>
<tr>
<td class="col-subject">I</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.12</td>
<td>0.14</td>
<td>0.15</td>
<td>0.17</td>
<td>0.21</td>
<td>0.44</td>
<td>0.14</td>
<td>0.08</td>
<td>0.41</td>
<td>0.64</td>
<td>1.45</td>
<td>1.78</td>
<td>2.02</td>
<td>0.39</td>
</tr>
<tr>
<td class="col-subject">J</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">13.5 to<br />
less than 14.5</td>
<td>0.41</td>
<td>0.35</td>
<td>0.27</td>
<td>0.19</td>
<td>0.48</td>
<td>0.45</td>
<td>0.39</td>
<td>0.05</td>
<td>0.15</td>
<td>0.20</td>
<td>2.27</td>
<td>2.04</td>
<td>1.76</td>
<td>0.35</td>
</tr>
</tbody>
</table>
</div>
</div>The post <a href="https://koueitrading.com/global/product/koken-hi-luck-655-02-disposable-dust-mask/">Koken Hi-Luck 655-02 Disposable Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken Hi-Luck 550 Disposable Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-hi-luck-550-disposable-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 12 Mar 2020 06:13:11 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192587</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: Hi-Luck 550 Important points when wearing a respirator Dust respirators use high-efficiency filters to prevent the inhalation of hazardous dust. To protect yourself from inhaling dust when wearing a dust respirator, the performance of this filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are extremely important. 1. [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-hi-luck-550-disposable-dust-mask/">Koken Hi-Luck 550 Disposable Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: Hi-Luck 550</p>
<h2>Important points when wearing a respirator</h2>
<p>Dust respirators use high-efficiency filters to prevent the inhalation of hazardous dust. To protect yourself from inhaling dust when wearing a dust respirator, the performance of this filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are extremely important.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Through unique technology, the sheep wool is electrostatically charged, and this electrostatic force draws particles to the fiber surface. This is the primary mechanism for collecting particles. A high-density fiber structure is not required, thus integrating the two contrasting features of &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221;</p>
<p>It consistently maintains the highest standard of performance and quality, and has been utilized for a long time as an outstanding filter.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" sizes="auto, (max-width: 317px) 100vw, 317px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png 317w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333-300x204.png 300w" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" sizes="auto, (max-width: 316px) 100vw, 316px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png 316w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322-300x227.png 300w" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applicable products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the filter&#8217;s fiber density improves collection efficiency. To meet airflow resistance standards, paper filters require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into a pristine circular shape in a single process to create the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" sizes="auto, (max-width: 329px) 100vw, 329px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751-300x116.png 300w" alt="" width="329" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" sizes="auto, (max-width: 321px) 100vw, 321px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png 321w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803-300x227.png 300w" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applicable products are from P.8 to P.11</p>
<p data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to national assay standards based on national regulations. The contents of these standards are comprehensive, ensuring the manufacture of products that meet strict safety requirements.</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td width="64">In addition to JIS standards, dust respirators are tested according to national assay standards based on national regulations. The contents of these standards are comprehensive, ensuring the manufacture of products that meet strict safety requirements.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the &#8220;Dust Respirator Standards&#8221;.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Aerosol</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride) particles</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate) particles</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ/min</td>
<td class="text-center" colspan="2">85 ℓ/min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement, must meet the value in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" colspan="2">For NaCl test aerosol<br />
Loaded up to 100mg</td>
<td class="text-left" colspan="2">For DOP test aerosol<br />
Loaded up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or more</td>
<td>RL1</td>
<td class="text-center">80.0% or more</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or more</td>
<td>RL2</td>
<td class="text-center">95.0% or more</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or more</td>
<td>RL3</td>
<td class="text-center">99.9% or more</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or more</td>
<td>DL1</td>
<td class="text-center">80.0% or more</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or more</td>
<td>DL2</td>
<td class="text-center">95.0% or more</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or more</td>
<td>DL3</td>
<td class="text-center">99.9% or more</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>( ) indicates products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col">Exhalation valve operation leak test</td>
<td>&#8211; When air is drawn, the internal pressure must decrease immediately<br />
&#8211; The time for internal pressure to return to normal atmospheric pressure must be 15 seconds or more</td>
</tr>
<tr>
<th class="header-col"><strong>Carbon Dioxide (CO2) Concentration Increase</strong></th>
<td class="content-col" colspan="2">Using a test headform and an artificial lung to inhale/exhale air containing CO2. The difference in CO2 concentration in the inhaled air between wearing and not wearing the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space Volume</strong></th>
<td class="content-col" colspan="2">Calculated from the (Carbon Dioxide Concentration Increase Test)</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Aerosol</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">Measured at 40 ℓ/min after loading test dust at 85 ℓ/min</td>
</tr>
<tr>
<td class="header-sub">Amount loaded onto dust respirator</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Aerosol and Collection Efficiency </span><span class="bottom-left-text">Disposable Type<br />
/ Replaceable Type</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" rowspan="2"><strong>Classification</strong><br />
<strong>(Particle Collection Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender"><strong>Test aerosol is solid Sodium Chloride (NaCl)</strong></th>
<th class="bg-lavender"><strong>Test aerosol is liquid Dioctyl Phthalate (DOP)</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
</tbody>
</table>
<h2>High-Performance Filter + Facepiece Designed for Easy Fit</h2>
<h3>2. Facepiece Fit Technology</h3>
<p>Even if a dust respirator has a high collection efficiency filter, it is meaningless if dust leaks through the face-to-mask seal during use. This is primarily caused by a &#8220;gap at the face contact area when worn.&#8221;</p>
<p>We consider mask fit to be just as important as filter performance. Therefore, our company has long developed technologies to enhance the airtightness of the facepiece seal.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" sizes="auto, (max-width: 247px) 100vw, 247px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg 775w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-227x300.jpg 227w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-768x1015.jpg 768w" alt="" width="247" height="326" /></p>
<p><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and effortlessly adapts to facial movements, ensuring a comfortable fit. The material also remains stable during use.</p>
<p><strong>HAWC Lip Structure</strong><br />
The lip design ensures a high degree of adhesion, maximizing the &#8220;suction cup&#8221; effect when wearing the mask to ensure an airtight facial seal.<img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" sizes="auto, (max-width: 145px) 100vw, 145px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png 319w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014-267x300.png 267w" alt="" width="145" height="163" /></p>
<p><strong>Free Position Under Chin</strong><br />
The unique curve of the face contact area prevents dust from leaking in. By aligning the nose portion first, it accommodates various facial dimensions, providing a secure fit for a wide range of face sizes (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" sizes="auto, (max-width: 192px) 100vw, 192px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png 410w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024-300x180.png 300w" alt="" width="192" height="115" /></p>
<p><strong data-start="56" data-end="112">Fit Status of the Free Position Under Chin Mask</strong><br data-start="112" data-end="115" />(Simulated image with the mask cut away to clearly show where it contacts the chin).</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong data-start="56" data-end="94">For individuals with large faces:</strong><br data-start="94" data-end="97" />The outer section of the mask rests naturally against the chin to provide a proper fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td width="64"><strong data-start="164" data-end="202">For individuals with small faces:</strong><br data-start="202" data-end="205" />The inner section of the mask naturally positions itself against the chin to secure the fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Wearing Stability</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Built-in Fit Checker</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed to naturally conform to various facial sizes and shapes, providing a seamless fit.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Uses a 3D-shaped polyband harness that conforms to the shape of the head, cradling it to enhance fit and sealing performance.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>A built-in fit checker allows you to test the mask&#8217;s seal at any time (available for the 1005, 1010A, 1015, and 1180 series).</td>
</tr>
</tbody>
</table>
<h2 data-start="39" data-end="62"><strong data-start="39" data-end="62">Disposable Dust Respirators</strong></h2>
<p data-start="64" data-end="89"><strong data-start="64" data-end="89">FF Lip (Free Fit Lip)</strong></p>
<p data-start="91" data-end="595">The most important factor when choosing a disposable mask is ensuring a secure fit to the face. The reason the Hi-Luck series provides an excellent fit is that the FF Lip has a shape that easily adapts to various facial sizes and contours.</p>
<p data-start="91" data-end="595">The FF Lip features a wide surface area and a soft design, providing superior sealing capability while easily conforming to facial movements. This prevents seal displacement during use, delivering a natural and tight seal as if the mask were custom-made.</p>
<p data-start="91" data-end="595"><img loading="lazy" decoding="async" class="aligncenter wp-image-56478" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954.png" sizes="auto, (max-width: 254px) 100vw, 254px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954.png 525w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954-300x275.png 300w" alt="" width="254" height="233" /></p>
<p data-start="91" data-end="595"><strong>Three Types of Straps to Choose From</strong></p>
<p data-start="91" data-end="595"><img loading="lazy" decoding="async" class=" wp-image-192566 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-300x79.jpg" alt="" width="486" height="128" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-300x79.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-768x203.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1.jpg 1024w" sizes="auto, (max-width: 486px) 100vw, 486px" /></p>
<p data-start="22" data-end="80"><strong data-start="22" data-end="80">Adjusting the Strap Length for a Perfect Fit</strong></p>
<p data-start="82" data-end="266">To ensure proper mask adhesion, &#8220;adjusting the strap length&#8221; is crucial. If the straps do not fit well or if a gap forms during work, it is unsafe.</p>
<ul>
<li data-start="270" data-end="315">The straps must be positioned correctly for stability.</li>
<li data-start="318" data-end="356">Adjust the length to ensure a snug fit.</li>
</ul>
<p data-start="22" data-end="57"><strong data-start="22" data-end="57">Uses a Synthetic Rubber Strap</strong></p>
<p data-start="59" data-end="154">The strap absorbs moisture well, feels soft against the skin, and prevents allergic reactions associated with natural rubber.</p>
<p data-start="59" data-end="154"><img loading="lazy" decoding="async" class="aligncenter wp-image-56480" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421.png" sizes="auto, (max-width: 195px) 100vw, 195px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421-300x274.png 300w" alt="" width="195" height="178" /></p>
<p data-start="156" data-end="243" data-is-last-node="" data-is-only-node="">The strap length can be adjusted while wearing the mask to accommodate different facial sizes.</p>
<p data-start="22" data-end="62"><strong data-start="22" data-end="62">Easy to Wear &#8211; T-Type (Hook Style)</strong></p>
<ul>
<li data-start="66" data-end="83">Does not tangle hair.</li>
<li data-start="86" data-end="122">Adjustable strap length.</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56481" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505.png" sizes="auto, (max-width: 207px) 100vw, 207px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505.png 312w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505-300x217.png 300w" alt="" width="207" height="150" /></p>
<p data-start="124" data-end="203" data-is-last-node="" data-is-only-node="">Simply pull the strap over the head, wrap it around the sides, and secure it with the hook.</p>
<p data-start="0" data-end="46"><strong data-start="0" data-end="46">Even Softer Wearing Feel (TK Hook Style)</strong></p>
<ul>
<li data-start="50" data-end="67">Does not tangle hair.</li>
<li data-start="70" data-end="121">Adjustable strap length and tension.</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56482" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626.png" sizes="auto, (max-width: 198px) 100vw, 198px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626.png 313w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626-300x219.png 300w" alt="" width="198" height="145" /></p>
<p data-start="123" data-end="225" data-is-last-node="" data-is-only-node="">The tightness of the upper and lower straps can be individually adjusted for an optimal fit, reducing pressure on the ears.</p>
<h2 data-start="123" data-end="225">Hi-Luck Series</h2>
<h3><strong data-start="47" data-end="82">Information on Hi-Luck 550 Respirator</strong></h3>
<p>DS1 Standard: Specifically incorporates a carbon filter to deodorize offensive odors generated from organic solvents.<br />
<b data-path-to-node="3" data-index-in-node="0">Warning:</b> Danger &#8211; This is NOT a gas respirator (do not use in environments with high concentrations of toxic gas).</p>
<p><img loading="lazy" decoding="async" class="wp-image-56501 aligncenter" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-125557.png" alt="" width="245" height="208" /></p>
<ul>
<li data-path-to-node="4,0,0">FF (Free Fit Lip)</li>
<li data-path-to-node="4,1,0">Activated Carbon</li>
</ul>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Standard:</b> Complies with TM383 certification, Assigned Protection Factor of 4.</p>
<h3><strong data-start="61" data-end="80">Bipromicron Filter </strong>(Models 650, 655)</h3>
<p data-start="99" data-end="285">This is a high-performance filter recycled from the leftover raw materials of molded high-efficiency filters. The filter material is repurposed and processed into a new high-performance filter.</p>
<p data-start="287" data-end="456"><strong>Recycled Material</strong><br data-start="307" data-end="310" />We are effectively utilizing waste as a resource. This is an eco-friendly filter created from recycled filter materials.</p>
<p data-start="287" data-end="456"><img loading="lazy" decoding="async" class=" wp-image-192565 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-300x187.jpg" alt="" width="420" height="262" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-300x187.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-768x478.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1.jpg 1024w" sizes="auto, (max-width: 420px) 100vw, 420px" /></p>
<h3 data-start="34" data-end="87"><strong data-start="34" data-end="66">Shape Recovery Structure </strong>(Models 550, 555 excluded)</h3>
<p data-start="89" data-end="274">The inside of the mask is reinforced with a shape-retaining mesh so that it does not lose its form when folded. This ensures the mask maintains its shape even when folded during breaks or short intervals.</p>
<p data-start="276" data-end="289"><strong>Hygiene</strong></p>
<ul>
<li data-start="292" data-end="379">When not in use, you can fold the mask closed to prevent dust from entering the inside of the facepiece.</li>
<li data-start="382" data-end="488">During hot or cold seasons, moisture from breathing may penetrate the mask, but this does not affect its performance.</li>
</ul>
<h3 data-start="34" data-end="162"><strong data-start="34" data-end="63">Completely Incinerable</strong></h3>
<p>The material contains no chloride compounds, so it does not generate toxic gases like dioxins when incinerated.</p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56485" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-113256.png" alt="" width="137" height="164" /></p>
<p><strong data-start="164" data-end="198">Metal-Free Design</strong><br data-start="198" data-end="201" />With the FF Lip design, an excellent seal is achieved without the use of metal parts such as nose clips.</p>
<h3>Features:</h3>
<ul>
<li data-start="36" data-end="124"><strong data-start="36" data-end="42">FF Lip</strong>: The Free Fit Lip design improves airtightness and provides a secure fit to the face.</li>
<li data-start="127" data-end="220"><strong data-start="127" data-end="149">Shape Recovery</strong>: Easily folds away during breaks or transit without losing its structural integrity.</li>
<li data-start="223" data-end="286"><strong data-start="223" data-end="233">Exhalation Valve</strong>: Facilitates easier exhalation and reduces heat buildup.</li>
<li data-start="289" data-end="372"><strong data-start="289" data-end="298">Bipro</strong>: Filter manufactured using recycled materials from ecological sources.</li>
<li data-start="375" data-end="455"><strong data-start="375" data-end="395">Activated Carbon</strong>: Filters out low levels of ozone gas, aiding in air purification.</li>
</ul>
<h3>Performance Specifications</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th class="header-main" colspan="2"><strong>Performance</strong></th>
<th><strong>Model</strong><br />
<strong>350 / 350T</strong></th>
<th><strong>Model</strong><br />
<strong>355 / 355T</strong></th>
<th><strong>Model</strong><br />
<strong>350TK</strong></th>
<th><strong>Model</strong><br />
<strong>355TK</strong></th>
<th><strong>Model</strong><br />
<strong>650 / 650T</strong></th>
<th><strong>Model</strong><br />
<strong>655 / 655T</strong></th>
<th><strong>Model</strong><br />
<strong>550</strong></th>
<th><strong>Model</strong><br />
<strong>555</strong></th>
<th><strong>Model</strong><br />
<strong>330</strong></th>
<th><strong>Model</strong><br />
<strong>335</strong></th>
</tr>
</thead>
<tbody>
<tr>
<th class="row-label" colspan="2"><strong>Particle Collection Efficiency</strong><br />
<strong><span class="small-text">(NaCl particles)</span></strong></th>
<td>95.0% or more<br />
(98.4%)</td>
<td>95.0% or more<br />
(97.9%)</td>
<td>95.0% or more<br />
(98.31%)</td>
<td>95.0% or more<br />
(98.18%)</td>
<td>95.0% or more<br />
(99.4%)</td>
<td>95.0% or more<br />
(99.0%)</td>
<td>80.0% or more<br />
(89.3%)</td>
<td>80.0% or more<br />
(88.6%)</td>
<td>80.0% or more<br />
(89.73%)</td>
<td>95.0% or more<br />
(98.46%)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Inhalation Resistance</strong></th>
<td>50Pa or less<br />
(35Pa)</td>
<td>50Pa or less<br />
(37Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>50Pa or less<br />
(39Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>52Pa or less<br />
(40Pa)</td>
<td>40Pa or less<br />
(29Pa)</td>
<td>43Pa or less<br />
(32Pa)</td>
<td>45Pa or less<br />
(28Pa)</td>
<td>70Pa or less<br />
(50Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Exhalation Resistance</strong></th>
<td>50Pa or less<br />
(35Pa)</td>
<td>36Pa or less<br />
(21Pa)</td>
<td>50Pa or less<br />
(35Pa)</td>
<td>36Pa or less<br />
(21Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>36Pa or less<br />
(19Pa)</td>
<td>40Pa or less<br />
(29Pa)</td>
<td>28Pa or less<br />
(18Pa)</td>
<td>45Pa or less<br />
(29Pa)</td>
<td>40Pa or less<br />
(22Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Inhalation Resistance Increase</strong></th>
<td>―<br />
(135Pa)</td>
<td>―<br />
(203Pa)</td>
<td>―<br />
(131Pa)</td>
<td>―<br />
(160Pa)</td>
<td>―<br />
(90Pa)</td>
<td>―<br />
(113Pa)</td>
<td>―<br />
(97Pa)</td>
<td>―<br />
(147Pa)</td>
<td>―<br />
(122Pa)</td>
<td>―<br />
(208Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>CO2 Concentration Increase</strong><br />
<strong>/ Dead Space</strong></th>
<td>1.0% or less / 400cm³ or less<br />
(0.45% / 178cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.41% / 165cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.42% / 166cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.39% / 156cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.37% / 149cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.39% / 156cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.73% / 293cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.71% / 283cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.38% / 152cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.34% / 136cm³)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Wet Resistance Value</strong></th>
<td>―<br />
(31Pa)</td>
<td>―<br />
(22Pa)</td>
<td>―<br />
(29Pa)</td>
<td>―<br />
(18Pa)</td>
<td>―<br />
(30Pa)</td>
<td>―<br />
(17Pa)</td>
<td>―<br />
(25Pa)</td>
<td>―<br />
(16Pa)</td>
<td>―<br />
(24Pa)</td>
<td>―<br />
(18Pa)</td>
</tr>
<tr>
<th class="row-label" rowspan="3"><strong>Weight</strong></th>
<th class="row-label"><strong>2-Strap Type</strong></th>
<td>Model 350: 12.1g or less<br />
(9.1g)</td>
<td>Model 355: 14.1g or less<br />
(11.1g)</td>
<td>―</td>
<td>―</td>
<td>Model 650: 12.6g or less<br />
(9.9g)</td>
<td>Model 655: 14.5g or less<br />
(11.8g)</td>
<td>12.3g or less (10.1g)</td>
<td>14.1g or less (11.8g)</td>
<td>―</td>
<td>―</td>
</tr>
<tr>
<th class="row-label"><strong>Hook Type</strong></th>
<td>Model 350T: 12.7g or less<br />
(9.7g)</td>
<td>Model 355T: 14.5g or less<br />
(11.5g)</td>
<td>―</td>
<td>―</td>
<td>Model 650T: 13.1g or less<br />
(10.2g)</td>
<td>Model 655T: 15.0g or less<br />
(12.4g)</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>―</td>
</tr>
<tr>
<th class="row-label"><strong>TK Hook Type</strong></th>
<td>―</td>
<td>―</td>
<td>13.3g or less<br />
(10.4g)</td>
<td>15.3g or less<br />
(12.3g)</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>12.5g or less<br />
(9.9g)</td>
<td>14.5g or less<br />
(11.7g)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Maximum Use Time Limit</strong></th>
<td>13 Hours</td>
<td>15 Hours</td>
<td>13 Hours</td>
<td>15 Hours</td>
<td>20 Hours</td>
<td>25 Hours</td>
<td>12 Hours</td>
<td>13 Hours</td>
<td>10 Hours</td>
<td>8 Hours</td>
</tr>
</tbody>
</table>
<p>Models 350TK, 355TK, 330, and 335 use the TK hook type strap. Models 350T, 355T, 650T, and 655T use the standard hook type strap.<br />
Values in ( ) indicate average values.</p>
<h3 data-start="34" data-end="59"><strong data-start="34" data-end="59">Regarding usage time:</strong></h3>
<p data-start="62" data-end="200">When using a disposable respirator, the maximum use time is specified according to the standards of the Japanese Society of Respiratory Protection Engineers.<br />
When supplied with 0.1g NaCl / minute at an airflow of 40L/minute, the usage time of this respirator will meet the Japanese national standard for dust respirators, until it exceeds 1.5 times the specified value.</p>
<p data-start="62" data-end="200">However, you must replace the mask in the following situations:</p>
<ul>
<li data-start="480" data-end="501">When breathing becomes difficult.</li>
<li data-start="506" data-end="537">When the mask is damaged or heavily soiled.</li>
<li data-start="542" data-end="566">When the mask becomes deformed.</li>
</ul>
<h3 class="table-title">Inward Leakage Rate</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th class="col-subject" rowspan="2"><strong>Test</strong><br />
<strong>Subject</strong></th>
<th><strong>Lip Width (cm)</strong></th>
<th><strong>Nose-Chin Distance (cm)</strong></th>
<th colspan="14"><strong>Leakage Rate (%)</strong></th>
</tr>
<tr>
<th><strong>Specification</strong></th>
<th><strong>Specification</strong></th>
<th><strong>Model</strong><br />
<strong>350</strong></th>
<th><strong>Model</strong><br />
<strong>350T</strong></th>
<th><strong>Model</strong><br />
<strong>355</strong></th>
<th><strong>Model</strong><br />
<strong>355T</strong></th>
<th><strong>Model</strong><br />
<strong>350TK</strong></th>
<th><strong>Model</strong><br />
<strong>355TK</strong></th>
<th><strong>Model</strong><br />
<strong>650</strong></th>
<th><strong>Model</strong><br />
<strong>650T</strong></th>
<th><strong>Model</strong><br />
<strong>655</strong></th>
<th><strong>Model</strong><br />
<strong>655T</strong></th>
<th><strong>Model</strong><br />
<strong>550</strong></th>
<th><strong>Model</strong><br />
<strong>555</strong></th>
<th><strong>Model</strong><br />
<strong>330</strong></th>
<th><strong>Model</strong><br />
<strong>335</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td class="col-subject">A</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">10.5 to<br />
less than 11.5</td>
<td>0.15</td>
<td>0.24</td>
<td>0.18</td>
<td>0.27</td>
<td>0.19</td>
<td>0.30</td>
<td>0.07</td>
<td>0.11</td>
<td>0.47</td>
<td>0.14</td>
<td>1.83</td>
<td>1.63</td>
<td>0.26</td>
<td>0.34</td>
</tr>
<tr>
<td class="col-subject">B</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.42</td>
<td>0.32</td>
<td>0.57</td>
<td>0.41</td>
<td>0.36</td>
<td>0.27</td>
<td>0.08</td>
<td>0.20</td>
<td>0.31</td>
<td>0.36</td>
<td>1.29</td>
<td>1.85</td>
<td>0.57</td>
<td>0.13</td>
</tr>
<tr>
<td class="col-subject">C</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.18</td>
<td>0.19</td>
<td>0.25</td>
<td>0.19</td>
<td>0.38</td>
<td>0.36</td>
<td>0.14</td>
<td>0.26</td>
<td>0.16</td>
<td>0.26</td>
<td>1.43</td>
<td>2.45</td>
<td>1.65</td>
<td>0.24</td>
</tr>
<tr>
<td class="col-subject">D</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">10.5 to<br />
less than 11.5</td>
<td>0.35</td>
<td>0.26</td>
<td>0.27</td>
<td>0.24</td>
<td>0.18</td>
<td>0.29</td>
<td>0.11</td>
<td>0.08</td>
<td>0.34</td>
<td>0.25</td>
<td>1.68</td>
<td>1.88</td>
<td>0.73</td>
<td>0.14</td>
</tr>
<tr>
<td class="col-subject">E</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.58</td>
<td>0.44</td>
<td>0.41</td>
<td>0.37</td>
<td>0.42</td>
<td>0.19</td>
<td>0.21</td>
<td>0.72</td>
<td>0.26</td>
<td>0.86</td>
<td>1.74</td>
<td>1.78</td>
<td>1.06</td>
<td>0.13</td>
</tr>
<tr>
<td class="col-subject">F</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.06</td>
<td>0.17</td>
<td>0.09</td>
<td>0.11</td>
<td>0.14</td>
<td>0.48</td>
<td>0.37</td>
<td>0.22</td>
<td>0.38</td>
<td>0.39</td>
<td>1.98</td>
<td>1.37</td>
<td>1.53</td>
<td>0.56</td>
</tr>
<tr>
<td class="col-subject">G</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">13.5 to<br />
less than 14.5</td>
<td>0.09</td>
<td>0.05</td>
<td>0.08</td>
<td>0.12</td>
<td>0.35</td>
<td>0.57</td>
<td>0.11</td>
<td>0.27</td>
<td>0.59</td>
<td>0.70</td>
<td>1.22</td>
<td>1.95</td>
<td>1.33</td>
<td>0.62</td>
</tr>
<tr>
<td class="col-subject">H</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.15</td>
<td>0.07</td>
<td>0.25</td>
<td>0.13</td>
<td>0.12</td>
<td>0.55</td>
<td>0.07</td>
<td>0.19</td>
<td>0.20</td>
<td>0.33</td>
<td>1.35</td>
<td>1.98</td>
<td>2.33</td>
<td>0.32</td>
</tr>
<tr>
<td class="col-subject">I</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.12</td>
<td>0.14</td>
<td>0.15</td>
<td>0.17</td>
<td>0.21</td>
<td>0.44</td>
<td>0.14</td>
<td>0.08</td>
<td>0.41</td>
<td>0.64</td>
<td>1.45</td>
<td>1.78</td>
<td>2.02</td>
<td>0.39</td>
</tr>
<tr>
<td class="col-subject">J</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">13.5 to<br />
less than 14.5</td>
<td>0.41</td>
<td>0.35</td>
<td>0.27</td>
<td>0.19</td>
<td>0.48</td>
<td>0.45</td>
<td>0.39</td>
<td>0.05</td>
<td>0.15</td>
<td>0.20</td>
<td>2.27</td>
<td>2.04</td>
<td>1.76</td>
<td>0.35</td>
</tr>
</tbody>
</table>
</div>
</div>The post <a href="https://koueitrading.com/global/product/koken-hi-luck-550-disposable-dust-mask/">Koken Hi-Luck 550 Disposable Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken Hi-Luck 555 Disposable Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-hi-luck-555-disposable-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 12 Mar 2020 04:45:29 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192571</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: Hi-Luck 555 Important points when wearing a respirator Dust respirators use high-efficiency filters to prevent the inhalation of hazardous dust. To protect yourself from inhaling dust when wearing a dust respirator, the performance of this filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are extremely important. 1. [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-hi-luck-555-disposable-dust-mask/">Koken Hi-Luck 555 Disposable Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: Hi-Luck 555</p>
<h2>Important points when wearing a respirator</h2>
<p>Dust respirators use high-efficiency filters to prevent the inhalation of hazardous dust. To protect yourself from inhaling dust when wearing a dust respirator, the performance of this filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are extremely important.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Through unique technology, the sheep wool is electrostatically charged, and this electrostatic force draws particles to the fiber surface. This is the primary mechanism for collecting particles. A high-density fiber structure is not required, thus integrating the two contrasting features of &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221;</p>
<p>It consistently maintains the highest standard of performance and quality, and has been utilized for a long time as an outstanding filter.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" sizes="auto, (max-width: 317px) 100vw, 317px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png 317w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333-300x204.png 300w" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" sizes="auto, (max-width: 316px) 100vw, 316px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png 316w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322-300x227.png 300w" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applicable products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the filter&#8217;s fiber density improves collection efficiency. To meet airflow resistance standards, paper filters require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into a pristine circular shape in a single process to create the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" sizes="auto, (max-width: 329px) 100vw, 329px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751-300x116.png 300w" alt="" width="329" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" sizes="auto, (max-width: 321px) 100vw, 321px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png 321w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803-300x227.png 300w" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applicable products are from P.8 to P.11</p>
<p data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to national assay standards based on national regulations. The contents of these standards are comprehensive, ensuring the manufacture of products that meet strict safety requirements.</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td width="64">In addition to JIS standards, dust respirators are tested according to national assay standards based on national regulations. The contents of these standards are comprehensive, ensuring the manufacture of products that meet strict safety requirements.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the &#8220;Dust Respirator Standards&#8221;.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Aerosol</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride) particles</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate) particles</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ/min</td>
<td class="text-center" colspan="2">85 ℓ/min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement, must meet the value in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" colspan="2">For NaCl test aerosol<br />
Loaded up to 100mg</td>
<td class="text-left" colspan="2">For DOP test aerosol<br />
Loaded up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or more</td>
<td>RL1</td>
<td class="text-center">80.0% or more</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or more</td>
<td>RL2</td>
<td class="text-center">95.0% or more</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or more</td>
<td>RL3</td>
<td class="text-center">99.9% or more</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or more</td>
<td>DL1</td>
<td class="text-center">80.0% or more</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or more</td>
<td>DL2</td>
<td class="text-center">95.0% or more</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or more</td>
<td>DL3</td>
<td class="text-center">99.9% or more</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>( ) indicates products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col">Exhalation valve operation leak test</td>
<td>&#8211; When air is drawn, the internal pressure must decrease immediately<br />
&#8211; The time for internal pressure to return to normal atmospheric pressure must be 15 seconds or more</td>
</tr>
<tr>
<th class="header-col"><strong>Carbon Dioxide (CO2) Concentration Increase</strong></th>
<td class="content-col" colspan="2">Using a test headform and an artificial lung to inhale/exhale air containing CO2. The difference in CO2 concentration in the inhaled air between wearing and not wearing the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space Volume</strong></th>
<td class="content-col" colspan="2">Calculated from the (Carbon Dioxide Concentration Increase Test)</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Aerosol</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">Measured at 40 ℓ/min after loading test dust at 85 ℓ/min</td>
</tr>
<tr>
<td class="header-sub">Amount loaded onto dust respirator</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Aerosol and Collection Efficiency </span><span class="bottom-left-text">Disposable Type<br />
/ Replaceable Type</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" rowspan="2"><strong>Classification</strong><br />
<strong>(Particle Collection Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender"><strong>Test aerosol is solid Sodium Chloride (NaCl)</strong></th>
<th class="bg-lavender"><strong>Test aerosol is liquid Dioctyl Phthalate (DOP)</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
</tbody>
</table>
<h2>High-Performance Filter + Facepiece Designed for Easy Fit</h2>
<h3>2. Facepiece Fit Technology</h3>
<p>Even if a dust respirator has a high collection efficiency filter, it is meaningless if dust leaks through the face-to-mask seal during use. This is primarily caused by a &#8220;gap at the face contact area when worn.&#8221;</p>
<p>We consider mask fit to be just as important as filter performance. Therefore, our company has long developed technologies to enhance the airtightness of the facepiece seal.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" sizes="auto, (max-width: 247px) 100vw, 247px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg 775w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-227x300.jpg 227w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-768x1015.jpg 768w" alt="" width="247" height="326" /></p>
<p><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and effortlessly adapts to facial movements, ensuring a comfortable fit. The material also remains stable during use.</p>
<p><strong>HAWC Lip Structure</strong><br />
The lip design ensures a high degree of adhesion, maximizing the &#8220;suction cup&#8221; effect when wearing the mask to ensure an airtight facial seal.<img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" sizes="auto, (max-width: 145px) 100vw, 145px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png 319w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014-267x300.png 267w" alt="" width="145" height="163" /></p>
<p><strong>Free Position Under Chin</strong><br />
The unique curve of the face contact area prevents dust from leaking in. By aligning the nose portion first, it accommodates various facial dimensions, providing a secure fit for a wide range of face sizes (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" sizes="auto, (max-width: 192px) 100vw, 192px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png 410w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024-300x180.png 300w" alt="" width="192" height="115" /></p>
<p><strong data-start="56" data-end="112">Fit Status of the Free Position Under Chin Mask</strong><br data-start="112" data-end="115" />(Simulated image with the mask cut away to clearly show where it contacts the chin).</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong data-start="56" data-end="94">For individuals with large faces:</strong><br data-start="94" data-end="97" />The outer section of the mask rests naturally against the chin to provide a proper fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td width="64"><strong data-start="164" data-end="202">For individuals with small faces:</strong><br data-start="202" data-end="205" />The inner section of the mask naturally positions itself against the chin to secure the fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Wearing Stability</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Built-in Fit Checker</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed to naturally conform to various facial sizes and shapes, providing a seamless fit.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Uses a 3D-shaped polyband harness that conforms to the shape of the head, cradling it to enhance fit and sealing performance.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>A built-in fit checker allows you to test the mask&#8217;s seal at any time (available for the 1005, 1010A, 1015, and 1180 series).</td>
</tr>
</tbody>
</table>
<h2 data-start="39" data-end="62"><strong data-start="39" data-end="62">Disposable Dust Respirators</strong></h2>
<p data-start="64" data-end="89"><strong data-start="64" data-end="89">FF Lip (Free Fit Lip)</strong></p>
<p data-start="91" data-end="595">The most important factor when choosing a disposable mask is ensuring a secure fit to the face. The reason the Hi-Luck series provides an excellent fit is that the FF Lip has a shape that easily adapts to various facial sizes and contours.</p>
<p data-start="91" data-end="595">The FF Lip features a wide surface area and a soft design, providing superior sealing capability while easily conforming to facial movements. This prevents seal displacement during use, delivering a natural and tight seal as if the mask were custom-made.</p>
<p data-start="91" data-end="595"><img loading="lazy" decoding="async" class="aligncenter wp-image-56478" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954.png" sizes="auto, (max-width: 254px) 100vw, 254px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954.png 525w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954-300x275.png 300w" alt="" width="254" height="233" /></p>
<p data-start="91" data-end="595"><strong>Three Types of Straps to Choose From</strong></p>
<p data-start="91" data-end="595"><img loading="lazy" decoding="async" class=" wp-image-192566 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-300x79.jpg" alt="" width="497" height="131" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-300x79.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-768x203.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1.jpg 1024w" sizes="auto, (max-width: 497px) 100vw, 497px" /></p>
<p data-start="22" data-end="80"><strong data-start="22" data-end="80">Adjusting the Strap Length for a Perfect Fit</strong></p>
<p data-start="82" data-end="266">To ensure proper mask adhesion, &#8220;adjusting the strap length&#8221; is crucial. If the straps do not fit well or if a gap forms during work, it is unsafe.</p>
<ul>
<li data-start="270" data-end="315">The straps must be positioned correctly for stability.</li>
<li data-start="318" data-end="356">Adjust the length to ensure a snug fit.</li>
</ul>
<p data-start="22" data-end="57"><strong data-start="22" data-end="57">Uses a Synthetic Rubber Strap</strong></p>
<p data-start="59" data-end="154">The strap absorbs moisture well, feels soft against the skin, and prevents allergic reactions associated with natural rubber.</p>
<p data-start="59" data-end="154"><img loading="lazy" decoding="async" class="aligncenter wp-image-56480" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421.png" sizes="auto, (max-width: 195px) 100vw, 195px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421-300x274.png 300w" alt="" width="195" height="178" /></p>
<p data-start="156" data-end="243" data-is-last-node="" data-is-only-node="">The strap length can be adjusted while wearing the mask to accommodate different facial sizes.</p>
<p data-start="22" data-end="62"><strong data-start="22" data-end="62">Easy to Wear &#8211; T-Type (Hook Style)</strong></p>
<ul>
<li data-start="66" data-end="83">Does not tangle hair.</li>
<li data-start="86" data-end="122">Adjustable strap length.</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56481" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505.png" sizes="auto, (max-width: 207px) 100vw, 207px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505.png 312w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505-300x217.png 300w" alt="" width="207" height="150" /></p>
<p data-start="124" data-end="203" data-is-last-node="" data-is-only-node="">Simply pull the strap over the head, wrap it around the sides, and secure it with the hook.</p>
<p data-start="0" data-end="46"><strong data-start="0" data-end="46">Even Softer Wearing Feel (TK Hook Style)</strong></p>
<ul>
<li data-start="50" data-end="67">Does not tangle hair.</li>
<li data-start="70" data-end="121">Adjustable strap length and tension.</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56482" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626.png" sizes="auto, (max-width: 198px) 100vw, 198px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626.png 313w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626-300x219.png 300w" alt="" width="198" height="145" /></p>
<p data-start="123" data-end="225" data-is-last-node="" data-is-only-node="">The tightness of the upper and lower straps can be individually adjusted for an optimal fit, reducing pressure on the ears.</p>
<h2 data-start="123" data-end="225">Hi-Luck Series</h2>
<h3 data-path-to-node="1"><b data-path-to-node="1" data-index-in-node="0">Information on Hi-Luck 555 Respirator</b></h3>
<p data-path-to-node="2">DS1 Standard: This is the Model 550 equipped with an added exhalation valve. This minimizes heat and moisture buildup from exhaled breath inside the mask, making breathing easier.<br />
<b data-path-to-node="3" data-index-in-node="0">Warning:</b> Danger &#8211; This is NOT a gas respirator.</p>
<p data-path-to-node="2"><img loading="lazy" decoding="async" class="wp-image-56504 aligncenter" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-14_130411-removebg-preview.png" alt="" width="238" height="219" /></p>
<ul>
<li data-path-to-node="4,0,0">FF (Free Fit Lip)</li>
<li data-path-to-node="4,1,0">Exhalation Valve</li>
<li data-path-to-node="4,2,0">Activated Carbon</li>
</ul>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Standard:</b> Complies with TM384 certification, Assigned Protection Factor of 4.</p>
<h3><strong data-start="61" data-end="80">Bipromicron Filter </strong>(Models 650, 655)</h3>
<p data-start="99" data-end="285">This is a high-performance filter recycled from the leftover raw materials of molded high-efficiency filters. The filter material is repurposed and processed into a new high-performance filter.</p>
<p data-start="287" data-end="456"><strong>Recycled Material</strong><br data-start="307" data-end="310" />We are effectively utilizing waste as a resource. This is an eco-friendly filter created from recycled filter materials.</p>
<p data-start="287" data-end="456"><img loading="lazy" decoding="async" class=" wp-image-192565 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-300x187.jpg" alt="" width="391" height="244" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-300x187.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-768x478.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1.jpg 1024w" sizes="auto, (max-width: 391px) 100vw, 391px" /></p>
<h3 data-start="34" data-end="87"><strong data-start="34" data-end="66">Shape Recovery Structure </strong>(Models 550, 555 excluded)</h3>
<p data-start="89" data-end="274">The inside of the mask is reinforced with a shape-retaining mesh so that it does not lose its form when folded. This ensures the mask maintains its shape even when folded during breaks or short intervals.</p>
<p data-start="276" data-end="289"><strong>Hygiene</strong></p>
<ul>
<li data-start="292" data-end="379">When not in use, you can fold the mask closed to prevent dust from entering the inside of the facepiece.</li>
<li data-start="382" data-end="488">During hot or cold seasons, moisture from breathing may penetrate the mask, but this does not affect its performance.</li>
</ul>
<h3 data-start="34" data-end="162"><strong data-start="34" data-end="63">Completely Incinerable</strong></h3>
<p>The material contains no chloride compounds, so it does not generate toxic gases like dioxins when incinerated.</p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56485" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-113256.png" alt="" width="137" height="164" /></p>
<p><strong data-start="164" data-end="198">Metal-Free Design</strong><br data-start="198" data-end="201" />With the FF Lip design, an excellent seal is achieved without the use of metal parts such as nose clips.</p>
<h3>Features:</h3>
<ul>
<li data-start="36" data-end="124"><strong data-start="36" data-end="42">FF Lip</strong>: The Free Fit Lip design improves airtightness and provides a secure fit to the face.</li>
<li data-start="127" data-end="220"><strong data-start="127" data-end="149">Shape Recovery</strong>: Easily folds away during breaks or transit without losing its structural integrity.</li>
<li data-start="223" data-end="286"><strong data-start="223" data-end="233">Exhalation Valve</strong>: Facilitates easier exhalation and reduces heat buildup.</li>
<li data-start="289" data-end="372"><strong data-start="289" data-end="298">Bipro</strong>: Filter manufactured using recycled materials from ecological sources.</li>
<li data-start="375" data-end="455"><strong data-start="375" data-end="395">Activated Carbon</strong>: Filters out low levels of ozone gas, aiding in air purification.</li>
</ul>
<h3>Performance Specifications</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th class="header-main" colspan="2"><strong>Performance</strong></th>
<th><strong>Model</strong><br />
<strong>350 / 350T</strong></th>
<th><strong>Model</strong><br />
<strong>355 / 355T</strong></th>
<th><strong>Model</strong><br />
<strong>350TK</strong></th>
<th><strong>Model</strong><br />
<strong>355TK</strong></th>
<th><strong>Model</strong><br />
<strong>650 / 650T</strong></th>
<th><strong>Model</strong><br />
<strong>655 / 655T</strong></th>
<th><strong>Model</strong><br />
<strong>550</strong></th>
<th><strong>Model</strong><br />
<strong>555</strong></th>
<th><strong>Model</strong><br />
<strong>330</strong></th>
<th><strong>Model</strong><br />
<strong>335</strong></th>
</tr>
</thead>
<tbody>
<tr>
<th class="row-label" colspan="2"><strong>Particle Collection Efficiency</strong><br />
<strong><span class="small-text">(NaCl particles)</span></strong></th>
<td>95.0% or more<br />
(98.4%)</td>
<td>95.0% or more<br />
(97.9%)</td>
<td>95.0% or more<br />
(98.31%)</td>
<td>95.0% or more<br />
(98.18%)</td>
<td>95.0% or more<br />
(99.4%)</td>
<td>95.0% or more<br />
(99.0%)</td>
<td>80.0% or more<br />
(89.3%)</td>
<td>80.0% or more<br />
(88.6%)</td>
<td>80.0% or more<br />
(89.73%)</td>
<td>95.0% or more<br />
(98.46%)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Inhalation Resistance</strong></th>
<td>50Pa or less<br />
(35Pa)</td>
<td>50Pa or less<br />
(37Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>50Pa or less<br />
(39Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>52Pa or less<br />
(40Pa)</td>
<td>40Pa or less<br />
(29Pa)</td>
<td>43Pa or less<br />
(32Pa)</td>
<td>45Pa or less<br />
(28Pa)</td>
<td>70Pa or less<br />
(50Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Exhalation Resistance</strong></th>
<td>50Pa or less<br />
(35Pa)</td>
<td>36Pa or less<br />
(21Pa)</td>
<td>50Pa or less<br />
(35Pa)</td>
<td>36Pa or less<br />
(21Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>36Pa or less<br />
(19Pa)</td>
<td>40Pa or less<br />
(29Pa)</td>
<td>28Pa or less<br />
(18Pa)</td>
<td>45Pa or less<br />
(29Pa)</td>
<td>40Pa or less<br />
(22Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Inhalation Resistance Increase</strong></th>
<td>―<br />
(135Pa)</td>
<td>―<br />
(203Pa)</td>
<td>―<br />
(131Pa)</td>
<td>―<br />
(160Pa)</td>
<td>―<br />
(90Pa)</td>
<td>―<br />
(113Pa)</td>
<td>―<br />
(97Pa)</td>
<td>―<br />
(147Pa)</td>
<td>―<br />
(122Pa)</td>
<td>―<br />
(208Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>CO2 Concentration Increase</strong><br />
<strong>/ Dead Space</strong></th>
<td>1.0% or less / 400cm³ or less<br />
(0.45% / 178cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.41% / 165cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.42% / 166cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.39% / 156cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.37% / 149cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.39% / 156cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.73% / 293cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.71% / 283cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.38% / 152cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.34% / 136cm³)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Wet Resistance Value</strong></th>
<td>―<br />
(31Pa)</td>
<td>―<br />
(22Pa)</td>
<td>―<br />
(29Pa)</td>
<td>―<br />
(18Pa)</td>
<td>―<br />
(30Pa)</td>
<td>―<br />
(17Pa)</td>
<td>―<br />
(25Pa)</td>
<td>―<br />
(16Pa)</td>
<td>―<br />
(24Pa)</td>
<td>―<br />
(18Pa)</td>
</tr>
<tr>
<th class="row-label" rowspan="3"><strong>Weight</strong></th>
<th class="row-label"><strong>2-Strap Type</strong></th>
<td>Model 350: 12.1g or less<br />
(9.1g)</td>
<td>Model 355: 14.1g or less<br />
(11.1g)</td>
<td>―</td>
<td>―</td>
<td>Model 650: 12.6g or less<br />
(9.9g)</td>
<td>Model 655: 14.5g or less<br />
(11.8g)</td>
<td>12.3g or less (10.1g)</td>
<td>14.1g or less (11.8g)</td>
<td>―</td>
<td>―</td>
</tr>
<tr>
<th class="row-label"><strong>Hook Type</strong></th>
<td>Model 350T: 12.7g or less<br />
(9.7g)</td>
<td>Model 355T: 14.5g or less<br />
(11.5g)</td>
<td>―</td>
<td>―</td>
<td>Model 650T: 13.1g or less<br />
(10.2g)</td>
<td>Model 655T: 15.0g or less<br />
(12.4g)</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>―</td>
</tr>
<tr>
<th class="row-label"><strong>TK Hook Type</strong></th>
<td>―</td>
<td>―</td>
<td>13.3g or less<br />
(10.4g)</td>
<td>15.3g or less<br />
(12.3g)</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>12.5g or less<br />
(9.9g)</td>
<td>14.5g or less<br />
(11.7g)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Maximum Use Time Limit</strong></th>
<td>13 Hours</td>
<td>15 Hours</td>
<td>13 Hours</td>
<td>15 Hours</td>
<td>20 Hours</td>
<td>25 Hours</td>
<td>12 Hours</td>
<td>13 Hours</td>
<td>10 Hours</td>
<td>8 Hours</td>
</tr>
</tbody>
</table>
<p>Models 350TK, 355TK, 330, and 335 use the TK hook type strap. Models 350T, 355T, 650T, and 655T use the standard hook type strap.<br />
Values in ( ) indicate average values.</p>
<h3 data-start="34" data-end="59"><strong data-start="34" data-end="59">Regarding usage time:</strong></h3>
<p data-start="62" data-end="200">When using a disposable respirator, the maximum use time is specified according to the standards of the Japanese Society of Respiratory Protection Engineers.<br />
When supplied with 0.1g NaCl / minute at an airflow of 40L/minute, the usage time of this respirator will meet the Japanese national standard for dust respirators, until it exceeds 1.5 times the specified value.</p>
<p data-start="62" data-end="200">However, you must replace the mask in the following situations:</p>
<ul>
<li data-start="480" data-end="501">When breathing becomes difficult.</li>
<li data-start="506" data-end="537">When the mask is damaged or heavily soiled.</li>
<li data-start="542" data-end="566">When the mask becomes deformed.</li>
</ul>
<h3 class="table-title">Inward Leakage Rate</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th class="col-subject" rowspan="2"><strong>Test</strong><br />
<strong>Subject</strong></th>
<th><strong>Lip Width (cm)</strong></th>
<th><strong>Nose-Chin Distance (cm)</strong></th>
<th colspan="14"><strong>Leakage Rate (%)</strong></th>
</tr>
<tr>
<th><strong>Specification</strong></th>
<th><strong>Specification</strong></th>
<th><strong>Model</strong><br />
<strong>350</strong></th>
<th><strong>Model</strong><br />
<strong>350T</strong></th>
<th><strong>Model</strong><br />
<strong>355</strong></th>
<th><strong>Model</strong><br />
<strong>355T</strong></th>
<th><strong>Model</strong><br />
<strong>350TK</strong></th>
<th><strong>Model</strong><br />
<strong>355TK</strong></th>
<th><strong>Model</strong><br />
<strong>650</strong></th>
<th><strong>Model</strong><br />
<strong>650T</strong></th>
<th><strong>Model</strong><br />
<strong>655</strong></th>
<th><strong>Model</strong><br />
<strong>655T</strong></th>
<th><strong>Model</strong><br />
<strong>550</strong></th>
<th><strong>Model</strong><br />
<strong>555</strong></th>
<th><strong>Model</strong><br />
<strong>330</strong></th>
<th><strong>Model</strong><br />
<strong>335</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td class="col-subject">A</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">10.5 to<br />
less than 11.5</td>
<td>0.15</td>
<td>0.24</td>
<td>0.18</td>
<td>0.27</td>
<td>0.19</td>
<td>0.30</td>
<td>0.07</td>
<td>0.11</td>
<td>0.47</td>
<td>0.14</td>
<td>1.83</td>
<td>1.63</td>
<td>0.26</td>
<td>0.34</td>
</tr>
<tr>
<td class="col-subject">B</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.42</td>
<td>0.32</td>
<td>0.57</td>
<td>0.41</td>
<td>0.36</td>
<td>0.27</td>
<td>0.08</td>
<td>0.20</td>
<td>0.31</td>
<td>0.36</td>
<td>1.29</td>
<td>1.85</td>
<td>0.57</td>
<td>0.13</td>
</tr>
<tr>
<td class="col-subject">C</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.18</td>
<td>0.19</td>
<td>0.25</td>
<td>0.19</td>
<td>0.38</td>
<td>0.36</td>
<td>0.14</td>
<td>0.26</td>
<td>0.16</td>
<td>0.26</td>
<td>1.43</td>
<td>2.45</td>
<td>1.65</td>
<td>0.24</td>
</tr>
<tr>
<td class="col-subject">D</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">10.5 to<br />
less than 11.5</td>
<td>0.35</td>
<td>0.26</td>
<td>0.27</td>
<td>0.24</td>
<td>0.18</td>
<td>0.29</td>
<td>0.11</td>
<td>0.08</td>
<td>0.34</td>
<td>0.25</td>
<td>1.68</td>
<td>1.88</td>
<td>0.73</td>
<td>0.14</td>
</tr>
<tr>
<td class="col-subject">E</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.58</td>
<td>0.44</td>
<td>0.41</td>
<td>0.37</td>
<td>0.42</td>
<td>0.19</td>
<td>0.21</td>
<td>0.72</td>
<td>0.26</td>
<td>0.86</td>
<td>1.74</td>
<td>1.78</td>
<td>1.06</td>
<td>0.13</td>
</tr>
<tr>
<td class="col-subject">F</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.06</td>
<td>0.17</td>
<td>0.09</td>
<td>0.11</td>
<td>0.14</td>
<td>0.48</td>
<td>0.37</td>
<td>0.22</td>
<td>0.38</td>
<td>0.39</td>
<td>1.98</td>
<td>1.37</td>
<td>1.53</td>
<td>0.56</td>
</tr>
<tr>
<td class="col-subject">G</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">13.5 to<br />
less than 14.5</td>
<td>0.09</td>
<td>0.05</td>
<td>0.08</td>
<td>0.12</td>
<td>0.35</td>
<td>0.57</td>
<td>0.11</td>
<td>0.27</td>
<td>0.59</td>
<td>0.70</td>
<td>1.22</td>
<td>1.95</td>
<td>1.33</td>
<td>0.62</td>
</tr>
<tr>
<td class="col-subject">H</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.15</td>
<td>0.07</td>
<td>0.25</td>
<td>0.13</td>
<td>0.12</td>
<td>0.55</td>
<td>0.07</td>
<td>0.19</td>
<td>0.20</td>
<td>0.33</td>
<td>1.35</td>
<td>1.98</td>
<td>2.33</td>
<td>0.32</td>
</tr>
<tr>
<td class="col-subject">I</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.12</td>
<td>0.14</td>
<td>0.15</td>
<td>0.17</td>
<td>0.21</td>
<td>0.44</td>
<td>0.14</td>
<td>0.08</td>
<td>0.41</td>
<td>0.64</td>
<td>1.45</td>
<td>1.78</td>
<td>2.02</td>
<td>0.39</td>
</tr>
<tr>
<td class="col-subject">J</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">13.5 to<br />
less than 14.5</td>
<td>0.41</td>
<td>0.35</td>
<td>0.27</td>
<td>0.19</td>
<td>0.48</td>
<td>0.45</td>
<td>0.39</td>
<td>0.05</td>
<td>0.15</td>
<td>0.20</td>
<td>2.27</td>
<td>2.04</td>
<td>1.76</td>
<td>0.35</td>
</tr>
</tbody>
</table>
</div>
</div>The post <a href="https://koueitrading.com/global/product/koken-hi-luck-555-disposable-dust-mask/">Koken Hi-Luck 555 Disposable Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken Hi-Luck 330 Disposable Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-hi-luck-330-disposable-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 12 Mar 2020 04:41:31 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192568</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: Hi-Luck 330 Important points when wearing a respirator Dust respirators use high-efficiency filters to prevent the inhalation of hazardous dust. To protect yourself from inhaling dust when wearing a dust respirator, the performance of this filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are extremely important. 1. [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-hi-luck-330-disposable-dust-mask/">Koken Hi-Luck 330 Disposable Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: Hi-Luck 330</p>
<h2>Important points when wearing a respirator</h2>
<p>Dust respirators use high-efficiency filters to prevent the inhalation of hazardous dust. To protect yourself from inhaling dust when wearing a dust respirator, the performance of this filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are extremely important.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Through unique technology, the sheep wool is electrostatically charged, and this electrostatic force draws particles to the fiber surface. This is the primary mechanism for collecting particles. A high-density fiber structure is not required, thus integrating the two contrasting features of &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221;</p>
<p>It consistently maintains the highest standard of performance and quality, and has been utilized for a long time as an outstanding filter.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" sizes="auto, (max-width: 317px) 100vw, 317px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png 317w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333-300x204.png 300w" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" sizes="auto, (max-width: 316px) 100vw, 316px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png 316w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322-300x227.png 300w" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applicable products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the filter&#8217;s fiber density improves collection efficiency. To meet airflow resistance standards, paper filters require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into a pristine circular shape in a single process to create the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" sizes="auto, (max-width: 329px) 100vw, 329px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751-300x116.png 300w" alt="" width="329" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" sizes="auto, (max-width: 321px) 100vw, 321px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png 321w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803-300x227.png 300w" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applicable products are from P.8 to P.11</p>
<p data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to national assay standards based on national regulations. The contents of these standards are comprehensive, ensuring the manufacture of products that meet strict safety requirements.</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td width="64">In addition to JIS standards, dust respirators are tested according to national assay standards based on national regulations. The contents of these standards are comprehensive, ensuring the manufacture of products that meet strict safety requirements.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the &#8220;Dust Respirator Standards&#8221;.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Aerosol</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride) particles</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate) particles</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ/min</td>
<td class="text-center" colspan="2">85 ℓ/min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement, must meet the value in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" colspan="2">For NaCl test aerosol<br />
Loaded up to 100mg</td>
<td class="text-left" colspan="2">For DOP test aerosol<br />
Loaded up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or more</td>
<td>RL1</td>
<td class="text-center">80.0% or more</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or more</td>
<td>RL2</td>
<td class="text-center">95.0% or more</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or more</td>
<td>RL3</td>
<td class="text-center">99.9% or more</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or more</td>
<td>DL1</td>
<td class="text-center">80.0% or more</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or more</td>
<td>DL2</td>
<td class="text-center">95.0% or more</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or more</td>
<td>DL3</td>
<td class="text-center">99.9% or more</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>( ) indicates products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col">Exhalation valve operation leak test</td>
<td>&#8211; When air is drawn, the internal pressure must decrease immediately<br />
&#8211; The time for internal pressure to return to normal atmospheric pressure must be 15 seconds or more</td>
</tr>
<tr>
<th class="header-col"><strong>Carbon Dioxide (CO2) Concentration Increase</strong></th>
<td class="content-col" colspan="2">Using a test headform and an artificial lung to inhale/exhale air containing CO2. The difference in CO2 concentration in the inhaled air between wearing and not wearing the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space Volume</strong></th>
<td class="content-col" colspan="2">Calculated from the (Carbon Dioxide Concentration Increase Test)</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Aerosol</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">Measured at 40 ℓ/min after loading test dust at 85 ℓ/min</td>
</tr>
<tr>
<td class="header-sub">Amount loaded onto dust respirator</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Aerosol and Collection Efficiency </span><span class="bottom-left-text">Disposable Type<br />
/ Replaceable Type</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" rowspan="2"><strong>Classification</strong><br />
<strong>(Particle Collection Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender"><strong>Test aerosol is solid Sodium Chloride (NaCl)</strong></th>
<th class="bg-lavender"><strong>Test aerosol is liquid Dioctyl Phthalate (DOP)</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
</tbody>
</table>
<h2>High-Performance Filter + Facepiece Designed for Easy Fit</h2>
<h3>2. Facepiece Fit Technology</h3>
<p>Even if a dust respirator has a high collection efficiency filter, it is meaningless if dust leaks through the face-to-mask seal during use. This is primarily caused by a &#8220;gap at the face contact area when worn.&#8221;</p>
<p>We consider mask fit to be just as important as filter performance. Therefore, our company has long developed technologies to enhance the airtightness of the facepiece seal.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" sizes="auto, (max-width: 247px) 100vw, 247px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg 775w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-227x300.jpg 227w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-768x1015.jpg 768w" alt="" width="247" height="326" /></p>
<p><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and effortlessly adapts to facial movements, ensuring a comfortable fit. The material also remains stable during use.</p>
<p><strong>HAWC Lip Structure</strong><br />
The lip design ensures a high degree of adhesion, maximizing the &#8220;suction cup&#8221; effect when wearing the mask to ensure an airtight facial seal.<img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" sizes="auto, (max-width: 145px) 100vw, 145px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png 319w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014-267x300.png 267w" alt="" width="145" height="163" /></p>
<p><strong>Free Position Under Chin</strong><br />
The unique curve of the face contact area prevents dust from leaking in. By aligning the nose portion first, it accommodates various facial dimensions, providing a secure fit for a wide range of face sizes (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" sizes="auto, (max-width: 192px) 100vw, 192px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png 410w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024-300x180.png 300w" alt="" width="192" height="115" /></p>
<p><strong data-start="56" data-end="112">Fit Status of the Free Position Under Chin Mask</strong><br data-start="112" data-end="115" />(Simulated image with the mask cut away to clearly show where it contacts the chin).</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong data-start="56" data-end="94">For individuals with large faces:</strong><br data-start="94" data-end="97" />The outer section of the mask rests naturally against the chin to provide a proper fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td width="64"><strong data-start="164" data-end="202">For individuals with small faces:</strong><br data-start="202" data-end="205" />The inner section of the mask naturally positions itself against the chin to secure the fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Wearing Stability</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Built-in Fit Checker</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed to naturally conform to various facial sizes and shapes, providing a seamless fit.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Uses a 3D-shaped polyband harness that conforms to the shape of the head, cradling it to enhance fit and sealing performance.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>A built-in fit checker allows you to test the mask&#8217;s seal at any time (available for the 1005, 1010A, 1015, and 1180 series).</td>
</tr>
</tbody>
</table>
<h2 data-start="39" data-end="62"><strong data-start="39" data-end="62">Disposable Dust Respirators</strong></h2>
<p data-start="64" data-end="89"><strong data-start="64" data-end="89">FF Lip (Free Fit Lip)</strong></p>
<p data-start="91" data-end="595">The most important factor when choosing a disposable mask is ensuring a secure fit to the face. The reason the Hi-Luck series provides an excellent fit is that the FF Lip has a shape that easily adapts to various facial sizes and contours.</p>
<p data-start="91" data-end="595">The FF Lip features a wide surface area and a soft design, providing superior sealing capability while easily conforming to facial movements. This prevents seal displacement during use, delivering a natural and tight seal as if the mask were custom-made.</p>
<p data-start="91" data-end="595"><img loading="lazy" decoding="async" class="aligncenter wp-image-56478" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954.png" sizes="auto, (max-width: 254px) 100vw, 254px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954.png 525w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954-300x275.png 300w" alt="" width="254" height="233" /></p>
<p data-start="91" data-end="595"><strong>Three Types of Straps to Choose From</strong></p>
<p data-start="91" data-end="595"><img loading="lazy" decoding="async" class=" wp-image-192566 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-300x79.jpg" alt="" width="494" height="130" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-300x79.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-768x203.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1.jpg 1024w" sizes="auto, (max-width: 494px) 100vw, 494px" /></p>
<p data-start="22" data-end="80"><strong data-start="22" data-end="80">Adjusting the Strap Length for a Perfect Fit</strong></p>
<p data-start="82" data-end="266">To ensure proper mask adhesion, &#8220;adjusting the strap length&#8221; is crucial. If the straps do not fit well or if a gap forms during work, it is unsafe.</p>
<ul>
<li data-start="270" data-end="315">The straps must be positioned correctly for stability.</li>
<li data-start="318" data-end="356">Adjust the length to ensure a snug fit.</li>
</ul>
<p data-start="22" data-end="57"><strong data-start="22" data-end="57">Uses a Synthetic Rubber Strap</strong></p>
<p data-start="59" data-end="154">The strap absorbs moisture well, feels soft against the skin, and prevents allergic reactions associated with natural rubber.</p>
<p data-start="59" data-end="154"><img loading="lazy" decoding="async" class="aligncenter wp-image-56480" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421.png" sizes="auto, (max-width: 195px) 100vw, 195px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421-300x274.png 300w" alt="" width="195" height="178" /></p>
<p data-start="156" data-end="243" data-is-last-node="" data-is-only-node="">The strap length can be adjusted while wearing the mask to accommodate different facial sizes.</p>
<p data-start="22" data-end="62"><strong data-start="22" data-end="62">Easy to Wear &#8211; T-Type (Hook Style)</strong></p>
<ul>
<li data-start="66" data-end="83">Does not tangle hair.</li>
<li data-start="86" data-end="122">Adjustable strap length.</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56481" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505.png" sizes="auto, (max-width: 207px) 100vw, 207px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505.png 312w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505-300x217.png 300w" alt="" width="207" height="150" /></p>
<p data-start="124" data-end="203" data-is-last-node="" data-is-only-node="">Simply pull the strap over the head, wrap it around the sides, and secure it with the hook.</p>
<p data-start="0" data-end="46"><strong data-start="0" data-end="46">Even Softer Wearing Feel (TK Hook Style)</strong></p>
<ul>
<li data-start="50" data-end="67">Does not tangle hair.</li>
<li data-start="70" data-end="121">Adjustable strap length and tension.</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56482" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626.png" sizes="auto, (max-width: 198px) 100vw, 198px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626.png 313w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626-300x219.png 300w" alt="" width="198" height="145" /></p>
<p data-start="123" data-end="225" data-is-last-node="" data-is-only-node="">The tightness of the upper and lower straps can be individually adjusted for an optimal fit, reducing pressure on the ears.</p>
<h2 data-start="123" data-end="225">Hi-Luck Series</h2>
<h3 data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">Information on Hi-Luck 330 Respirator</b></h3>
<p data-path-to-node="8"><b data-path-to-node="8" data-index-in-node="0">DS1 Standard:</b> Specifically designed with contact dimensions suitable for people with smaller faces. Uses the TK hook type for a soft, comfortable wearing feel.</p>
<p data-path-to-node="8"><img loading="lazy" decoding="async" class="wp-image-56507 aligncenter" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-14_130931-removebg-preview.png" alt="" width="261" height="213" /></p>
<ul>
<li data-path-to-node="9,0,0">FF (Free Fit Lip)</li>
<li data-path-to-node="9,1,0">Shape Recovery</li>
</ul>
<p data-path-to-node="10"><b data-path-to-node="10" data-index-in-node="0">Standard:</b> Complies with TM729 certification, Assigned Protection Factor of 4.</p>
<h3><strong data-start="61" data-end="80">Bipromicron Filter </strong>(Models 650, 655)</h3>
<p data-start="99" data-end="285">This is a high-performance filter recycled from the leftover raw materials of molded high-efficiency filters. The filter material is repurposed and processed into a new high-performance filter.</p>
<p data-start="287" data-end="456"><strong>Recycled Material</strong><br data-start="307" data-end="310" />We are effectively utilizing waste as a resource. This is an eco-friendly filter created from recycled filter materials.</p>
<p data-start="287" data-end="456"><img loading="lazy" decoding="async" class=" wp-image-192565 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-300x187.jpg" alt="" width="359" height="224" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-300x187.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-768x478.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1.jpg 1024w" sizes="auto, (max-width: 359px) 100vw, 359px" /></p>
<h3 data-start="34" data-end="87"><strong data-start="34" data-end="66">Shape Recovery Structure </strong>(Models 550, 555 excluded)</h3>
<p data-start="89" data-end="274">The inside of the mask is reinforced with a shape-retaining mesh so that it does not lose its form when folded. This ensures the mask maintains its shape even when folded during breaks or short intervals.</p>
<p data-start="276" data-end="289"><strong>Hygiene</strong></p>
<ul>
<li data-start="292" data-end="379">When not in use, you can fold the mask closed to prevent dust from entering the inside of the facepiece.</li>
<li data-start="382" data-end="488">During hot or cold seasons, moisture from breathing may penetrate the mask, but this does not affect its performance.</li>
</ul>
<h3 data-start="34" data-end="162"><strong data-start="34" data-end="63">Completely Incinerable</strong></h3>
<p>The material contains no chloride compounds, so it does not generate toxic gases like dioxins when incinerated.</p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56485" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-113256.png" alt="" width="137" height="164" /></p>
<p><strong data-start="164" data-end="198">Metal-Free Design</strong><br data-start="198" data-end="201" />With the FF Lip design, an excellent seal is achieved without the use of metal parts such as nose clips.</p>
<h3>Features:</h3>
<ul>
<li data-start="36" data-end="124"><strong data-start="36" data-end="42">FF Lip</strong>: The Free Fit Lip design improves airtightness and provides a secure fit to the face.</li>
<li data-start="127" data-end="220"><strong data-start="127" data-end="149">Shape Recovery</strong>: Easily folds away during breaks or transit without losing its structural integrity.</li>
<li data-start="223" data-end="286"><strong data-start="223" data-end="233">Exhalation Valve</strong>: Facilitates easier exhalation and reduces heat buildup.</li>
<li data-start="289" data-end="372"><strong data-start="289" data-end="298">Bipro</strong>: Filter manufactured using recycled materials from ecological sources.</li>
<li data-start="375" data-end="455"><strong data-start="375" data-end="395">Activated Carbon</strong>: Filters out low levels of ozone gas, aiding in air purification.</li>
</ul>
<h3>Performance Specifications</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th class="header-main" colspan="2"><strong>Performance</strong></th>
<th><strong>Model</strong><br />
<strong>350 / 350T</strong></th>
<th><strong>Model</strong><br />
<strong>355 / 355T</strong></th>
<th><strong>Model</strong><br />
<strong>350TK</strong></th>
<th><strong>Model</strong><br />
<strong>355TK</strong></th>
<th><strong>Model</strong><br />
<strong>650 / 650T</strong></th>
<th><strong>Model</strong><br />
<strong>655 / 655T</strong></th>
<th><strong>Model</strong><br />
<strong>550</strong></th>
<th><strong>Model</strong><br />
<strong>555</strong></th>
<th><strong>Model</strong><br />
<strong>330</strong></th>
<th><strong>Model</strong><br />
<strong>335</strong></th>
</tr>
</thead>
<tbody>
<tr>
<th class="row-label" colspan="2"><strong>Particle Collection Efficiency</strong><br />
<strong><span class="small-text">(NaCl particles)</span></strong></th>
<td>95.0% or more<br />
(98.4%)</td>
<td>95.0% or more<br />
(97.9%)</td>
<td>95.0% or more<br />
(98.31%)</td>
<td>95.0% or more<br />
(98.18%)</td>
<td>95.0% or more<br />
(99.4%)</td>
<td>95.0% or more<br />
(99.0%)</td>
<td>80.0% or more<br />
(89.3%)</td>
<td>80.0% or more<br />
(88.6%)</td>
<td>80.0% or more<br />
(89.73%)</td>
<td>95.0% or more<br />
(98.46%)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Inhalation Resistance</strong></th>
<td>50Pa or less<br />
(35Pa)</td>
<td>50Pa or less<br />
(37Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>50Pa or less<br />
(39Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>52Pa or less<br />
(40Pa)</td>
<td>40Pa or less<br />
(29Pa)</td>
<td>43Pa or less<br />
(32Pa)</td>
<td>45Pa or less<br />
(28Pa)</td>
<td>70Pa or less<br />
(50Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Exhalation Resistance</strong></th>
<td>50Pa or less<br />
(35Pa)</td>
<td>36Pa or less<br />
(21Pa)</td>
<td>50Pa or less<br />
(35Pa)</td>
<td>36Pa or less<br />
(21Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>36Pa or less<br />
(19Pa)</td>
<td>40Pa or less<br />
(29Pa)</td>
<td>28Pa or less<br />
(18Pa)</td>
<td>45Pa or less<br />
(29Pa)</td>
<td>40Pa or less<br />
(22Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Inhalation Resistance Increase</strong></th>
<td>―<br />
(135Pa)</td>
<td>―<br />
(203Pa)</td>
<td>―<br />
(131Pa)</td>
<td>―<br />
(160Pa)</td>
<td>―<br />
(90Pa)</td>
<td>―<br />
(113Pa)</td>
<td>―<br />
(97Pa)</td>
<td>―<br />
(147Pa)</td>
<td>―<br />
(122Pa)</td>
<td>―<br />
(208Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>CO2 Concentration Increase</strong><br />
<strong>/ Dead Space</strong></th>
<td>1.0% or less / 400cm³ or less<br />
(0.45% / 178cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.41% / 165cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.42% / 166cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.39% / 156cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.37% / 149cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.39% / 156cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.73% / 293cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.71% / 283cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.38% / 152cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.34% / 136cm³)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Wet Resistance Value</strong></th>
<td>―<br />
(31Pa)</td>
<td>―<br />
(22Pa)</td>
<td>―<br />
(29Pa)</td>
<td>―<br />
(18Pa)</td>
<td>―<br />
(30Pa)</td>
<td>―<br />
(17Pa)</td>
<td>―<br />
(25Pa)</td>
<td>―<br />
(16Pa)</td>
<td>―<br />
(24Pa)</td>
<td>―<br />
(18Pa)</td>
</tr>
<tr>
<th class="row-label" rowspan="3"><strong>Weight</strong></th>
<th class="row-label"><strong>2-Strap Type</strong></th>
<td>Model 350: 12.1g or less<br />
(9.1g)</td>
<td>Model 355: 14.1g or less<br />
(11.1g)</td>
<td>―</td>
<td>―</td>
<td>Model 650: 12.6g or less<br />
(9.9g)</td>
<td>Model 655: 14.5g or less<br />
(11.8g)</td>
<td>12.3g or less (10.1g)</td>
<td>14.1g or less (11.8g)</td>
<td>―</td>
<td>―</td>
</tr>
<tr>
<th class="row-label"><strong>Hook Type</strong></th>
<td>Model 350T: 12.7g or less<br />
(9.7g)</td>
<td>Model 355T: 14.5g or less<br />
(11.5g)</td>
<td>―</td>
<td>―</td>
<td>Model 650T: 13.1g or less<br />
(10.2g)</td>
<td>Model 655T: 15.0g or less<br />
(12.4g)</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>―</td>
</tr>
<tr>
<th class="row-label"><strong>TK Hook Type</strong></th>
<td>―</td>
<td>―</td>
<td>13.3g or less<br />
(10.4g)</td>
<td>15.3g or less<br />
(12.3g)</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>12.5g or less<br />
(9.9g)</td>
<td>14.5g or less<br />
(11.7g)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Maximum Use Time Limit</strong></th>
<td>13 Hours</td>
<td>15 Hours</td>
<td>13 Hours</td>
<td>15 Hours</td>
<td>20 Hours</td>
<td>25 Hours</td>
<td>12 Hours</td>
<td>13 Hours</td>
<td>10 Hours</td>
<td>8 Hours</td>
</tr>
</tbody>
</table>
<p>Models 350TK, 355TK, 330, and 335 use the TK hook type strap. Models 350T, 355T, 650T, and 655T use the standard hook type strap.<br />
Values in ( ) indicate average values.</p>
<h3 data-start="34" data-end="59"><strong data-start="34" data-end="59">Regarding usage time:</strong></h3>
<p data-start="62" data-end="200">When using a disposable respirator, the maximum use time is specified according to the standards of the Japanese Society of Respiratory Protection Engineers.<br />
When supplied with 0.1g NaCl / minute at an airflow of 40L/minute, the usage time of this respirator will meet the Japanese national standard for dust respirators, until it exceeds 1.5 times the specified value.</p>
<p data-start="62" data-end="200">However, you must replace the mask in the following situations:</p>
<ul>
<li data-start="480" data-end="501">When breathing becomes difficult.</li>
<li data-start="506" data-end="537">When the mask is damaged or heavily soiled.</li>
<li data-start="542" data-end="566">When the mask becomes deformed.</li>
</ul>
<h3 class="table-title">Inward Leakage Rate</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th class="col-subject" rowspan="2"><strong>Test</strong><br />
<strong>Subject</strong></th>
<th><strong>Lip Width (cm)</strong></th>
<th><strong>Nose-Chin Distance (cm)</strong></th>
<th colspan="14"><strong>Leakage Rate (%)</strong></th>
</tr>
<tr>
<th><strong>Specification</strong></th>
<th><strong>Specification</strong></th>
<th><strong>Model</strong><br />
<strong>350</strong></th>
<th><strong>Model</strong><br />
<strong>350T</strong></th>
<th><strong>Model</strong><br />
<strong>355</strong></th>
<th><strong>Model</strong><br />
<strong>355T</strong></th>
<th><strong>Model</strong><br />
<strong>350TK</strong></th>
<th><strong>Model</strong><br />
<strong>355TK</strong></th>
<th><strong>Model</strong><br />
<strong>650</strong></th>
<th><strong>Model</strong><br />
<strong>650T</strong></th>
<th><strong>Model</strong><br />
<strong>655</strong></th>
<th><strong>Model</strong><br />
<strong>655T</strong></th>
<th><strong>Model</strong><br />
<strong>550</strong></th>
<th><strong>Model</strong><br />
<strong>555</strong></th>
<th><strong>Model</strong><br />
<strong>330</strong></th>
<th><strong>Model</strong><br />
<strong>335</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td class="col-subject">A</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">10.5 to<br />
less than 11.5</td>
<td>0.15</td>
<td>0.24</td>
<td>0.18</td>
<td>0.27</td>
<td>0.19</td>
<td>0.30</td>
<td>0.07</td>
<td>0.11</td>
<td>0.47</td>
<td>0.14</td>
<td>1.83</td>
<td>1.63</td>
<td>0.26</td>
<td>0.34</td>
</tr>
<tr>
<td class="col-subject">B</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.42</td>
<td>0.32</td>
<td>0.57</td>
<td>0.41</td>
<td>0.36</td>
<td>0.27</td>
<td>0.08</td>
<td>0.20</td>
<td>0.31</td>
<td>0.36</td>
<td>1.29</td>
<td>1.85</td>
<td>0.57</td>
<td>0.13</td>
</tr>
<tr>
<td class="col-subject">C</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.18</td>
<td>0.19</td>
<td>0.25</td>
<td>0.19</td>
<td>0.38</td>
<td>0.36</td>
<td>0.14</td>
<td>0.26</td>
<td>0.16</td>
<td>0.26</td>
<td>1.43</td>
<td>2.45</td>
<td>1.65</td>
<td>0.24</td>
</tr>
<tr>
<td class="col-subject">D</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">10.5 to<br />
less than 11.5</td>
<td>0.35</td>
<td>0.26</td>
<td>0.27</td>
<td>0.24</td>
<td>0.18</td>
<td>0.29</td>
<td>0.11</td>
<td>0.08</td>
<td>0.34</td>
<td>0.25</td>
<td>1.68</td>
<td>1.88</td>
<td>0.73</td>
<td>0.14</td>
</tr>
<tr>
<td class="col-subject">E</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.58</td>
<td>0.44</td>
<td>0.41</td>
<td>0.37</td>
<td>0.42</td>
<td>0.19</td>
<td>0.21</td>
<td>0.72</td>
<td>0.26</td>
<td>0.86</td>
<td>1.74</td>
<td>1.78</td>
<td>1.06</td>
<td>0.13</td>
</tr>
<tr>
<td class="col-subject">F</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.06</td>
<td>0.17</td>
<td>0.09</td>
<td>0.11</td>
<td>0.14</td>
<td>0.48</td>
<td>0.37</td>
<td>0.22</td>
<td>0.38</td>
<td>0.39</td>
<td>1.98</td>
<td>1.37</td>
<td>1.53</td>
<td>0.56</td>
</tr>
<tr>
<td class="col-subject">G</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">13.5 to<br />
less than 14.5</td>
<td>0.09</td>
<td>0.05</td>
<td>0.08</td>
<td>0.12</td>
<td>0.35</td>
<td>0.57</td>
<td>0.11</td>
<td>0.27</td>
<td>0.59</td>
<td>0.70</td>
<td>1.22</td>
<td>1.95</td>
<td>1.33</td>
<td>0.62</td>
</tr>
<tr>
<td class="col-subject">H</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.15</td>
<td>0.07</td>
<td>0.25</td>
<td>0.13</td>
<td>0.12</td>
<td>0.55</td>
<td>0.07</td>
<td>0.19</td>
<td>0.20</td>
<td>0.33</td>
<td>1.35</td>
<td>1.98</td>
<td>2.33</td>
<td>0.32</td>
</tr>
<tr>
<td class="col-subject">I</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.12</td>
<td>0.14</td>
<td>0.15</td>
<td>0.17</td>
<td>0.21</td>
<td>0.44</td>
<td>0.14</td>
<td>0.08</td>
<td>0.41</td>
<td>0.64</td>
<td>1.45</td>
<td>1.78</td>
<td>2.02</td>
<td>0.39</td>
</tr>
<tr>
<td class="col-subject">J</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">13.5 to<br />
less than 14.5</td>
<td>0.41</td>
<td>0.35</td>
<td>0.27</td>
<td>0.19</td>
<td>0.48</td>
<td>0.45</td>
<td>0.39</td>
<td>0.05</td>
<td>0.15</td>
<td>0.20</td>
<td>2.27</td>
<td>2.04</td>
<td>1.76</td>
<td>0.35</td>
</tr>
</tbody>
</table>
</div>
</div>The post <a href="https://koueitrading.com/global/product/koken-hi-luck-330-disposable-dust-mask/">Koken Hi-Luck 330 Disposable Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken Hi-Luck 335 Disposable Dust Mask</title>
		<link>https://koueitrading.com/global/product/koken-hi-luck-335-disposable-dust-mask/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 12 Mar 2020 04:30:49 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192562</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: Hi-Luck 335 Important points when wearing a respirator Dust respirators use high-efficiency filters to prevent the inhalation of hazardous dust. To protect yourself from inhaling dust when wearing a dust respirator, the performance of this filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are extremely important. 1. [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-hi-luck-335-disposable-dust-mask/">Koken Hi-Luck 335 Disposable Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: Hi-Luck 335</p>
<h2>Important points when wearing a respirator</h2>
<p>Dust respirators use high-efficiency filters to prevent the inhalation of hazardous dust. To protect yourself from inhaling dust when wearing a dust respirator, the performance of this filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are extremely important.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Through unique technology, the sheep wool is electrostatically charged, and this electrostatic force draws particles to the fiber surface. This is the primary mechanism for collecting particles. A high-density fiber structure is not required, thus integrating the two contrasting features of &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221;</p>
<p>It consistently maintains the highest standard of performance and quality, and has been utilized for a long time as an outstanding filter.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" sizes="auto, (max-width: 317px) 100vw, 317px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png 317w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333-300x204.png 300w" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" sizes="auto, (max-width: 316px) 100vw, 316px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png 316w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322-300x227.png 300w" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applicable products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the filter&#8217;s fiber density improves collection efficiency. To meet airflow resistance standards, paper filters require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into a pristine circular shape in a single process to create the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" sizes="auto, (max-width: 329px) 100vw, 329px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751-300x116.png 300w" alt="" width="329" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" sizes="auto, (max-width: 321px) 100vw, 321px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png 321w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803-300x227.png 300w" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applicable products are from P.8 to P.11</p>
<p data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to national assay standards based on national regulations. The contents of these standards are comprehensive, ensuring the manufacture of products that meet strict safety requirements.</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td width="64">In addition to JIS standards, dust respirators are tested according to national assay standards based on national regulations. The contents of these standards are comprehensive, ensuring the manufacture of products that meet strict safety requirements.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the &#8220;Dust Respirator Standards&#8221;.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Aerosol</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride) particles</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate) particles</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ/min</td>
<td class="text-center" colspan="2">85 ℓ/min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement, must meet the value in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" colspan="2">For NaCl test aerosol<br />
Loaded up to 100mg</td>
<td class="text-left" colspan="2">For DOP test aerosol<br />
Loaded up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or more</td>
<td>RL1</td>
<td class="text-center">80.0% or more</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or more</td>
<td>RL2</td>
<td class="text-center">95.0% or more</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or more</td>
<td>RL3</td>
<td class="text-center">99.9% or more</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or more</td>
<td>DL1</td>
<td class="text-center">80.0% or more</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or more</td>
<td>DL2</td>
<td class="text-center">95.0% or more</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or more</td>
<td>DL3</td>
<td class="text-center">99.9% or more</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>( ) indicates products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col">Exhalation valve operation leak test</td>
<td>&#8211; When air is drawn, the internal pressure must decrease immediately<br />
&#8211; The time for internal pressure to return to normal atmospheric pressure must be 15 seconds or more</td>
</tr>
<tr>
<th class="header-col"><strong>Carbon Dioxide (CO2) Concentration Increase</strong></th>
<td class="content-col" colspan="2">Using a test headform and an artificial lung to inhale/exhale air containing CO2. The difference in CO2 concentration in the inhaled air between wearing and not wearing the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space Volume</strong></th>
<td class="content-col" colspan="2">Calculated from the (Carbon Dioxide Concentration Increase Test)</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Aerosol</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">Measured at 40 ℓ/min after loading test dust at 85 ℓ/min</td>
</tr>
<tr>
<td class="header-sub">Amount loaded onto dust respirator</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Aerosol and Collection Efficiency </span><span class="bottom-left-text">Disposable Type<br />
/ Replaceable Type</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" rowspan="2"><strong>Classification</strong><br />
<strong>(Particle Collection Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender"><strong>Test aerosol is solid Sodium Chloride (NaCl)</strong></th>
<th class="bg-lavender"><strong>Test aerosol is liquid Dioctyl Phthalate (DOP)</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
</tbody>
</table>
<h2>High-Performance Filter + Facepiece Designed for Easy Fit</h2>
<h3>2. Facepiece Fit Technology</h3>
<p>Even if a dust respirator has a high collection efficiency filter, it is meaningless if dust leaks through the face-to-mask seal during use. This is primarily caused by a &#8220;gap at the face contact area when worn.&#8221;</p>
<p>We consider mask fit to be just as important as filter performance. Therefore, our company has long developed technologies to enhance the airtightness of the facepiece seal.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" sizes="auto, (max-width: 247px) 100vw, 247px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg 775w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-227x300.jpg 227w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-768x1015.jpg 768w" alt="" width="247" height="326" /></p>
<p><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and effortlessly adapts to facial movements, ensuring a comfortable fit. The material also remains stable during use.</p>
<p><strong>HAWC Lip Structure</strong><br />
The lip design ensures a high degree of adhesion, maximizing the &#8220;suction cup&#8221; effect when wearing the mask to ensure an airtight facial seal.<img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" sizes="auto, (max-width: 145px) 100vw, 145px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png 319w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014-267x300.png 267w" alt="" width="145" height="163" /></p>
<p><strong>Free Position Under Chin</strong><br />
The unique curve of the face contact area prevents dust from leaking in. By aligning the nose portion first, it accommodates various facial dimensions, providing a secure fit for a wide range of face sizes (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" sizes="auto, (max-width: 192px) 100vw, 192px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png 410w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024-300x180.png 300w" alt="" width="192" height="115" /></p>
<p><strong data-start="56" data-end="112">Fit Status of the Free Position Under Chin Mask</strong><br data-start="112" data-end="115" />(Simulated image with the mask cut away to clearly show where it contacts the chin).</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong data-start="56" data-end="94">For individuals with large faces:</strong><br data-start="94" data-end="97" />The outer section of the mask rests naturally against the chin to provide a proper fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td width="64"><strong data-start="164" data-end="202">For individuals with small faces:</strong><br data-start="202" data-end="205" />The inner section of the mask naturally positions itself against the chin to secure the fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Wearing Stability</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Built-in Fit Checker</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed to naturally conform to various facial sizes and shapes, providing a seamless fit.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Uses a 3D-shaped polyband harness that conforms to the shape of the head, cradling it to enhance fit and sealing performance.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>A built-in fit checker allows you to test the mask&#8217;s seal at any time (available for the 1005, 1010A, 1015, and 1180 series).</td>
</tr>
</tbody>
</table>
<h2 data-start="39" data-end="62"><strong data-start="39" data-end="62">Disposable Dust Respirators</strong></h2>
<p data-start="64" data-end="89"><strong data-start="64" data-end="89">FF Lip (Free Fit Lip)</strong></p>
<p data-start="91" data-end="595">The most important factor when choosing a disposable mask is ensuring a secure fit to the face. The reason the Hi-Luck series provides an excellent fit is that the FF Lip has a shape that easily adapts to various facial sizes and contours.</p>
<p data-start="91" data-end="595">The FF Lip features a wide surface area and a soft design, providing superior sealing capability while easily conforming to facial movements. This prevents seal displacement during use, delivering a natural and tight seal as if the mask were custom-made.</p>
<p data-start="91" data-end="595"><img loading="lazy" decoding="async" class="aligncenter wp-image-56478" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954.png" sizes="auto, (max-width: 254px) 100vw, 254px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954.png 525w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-110954-300x275.png 300w" alt="" width="254" height="233" /></p>
<p data-start="91" data-end="595"><strong>Three Types of Straps to Choose From</strong></p>
<p data-start="91" data-end="595"><img loading="lazy" decoding="async" class=" wp-image-192566 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-300x79.jpg" alt="" width="475" height="125" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-300x79.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1-768x203.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-7-1.jpg 1024w" sizes="auto, (max-width: 475px) 100vw, 475px" /></p>
<p data-start="22" data-end="80"><strong data-start="22" data-end="80">Adjusting the Strap Length for a Perfect Fit</strong></p>
<p data-start="82" data-end="266">To ensure proper mask adhesion, &#8220;adjusting the strap length&#8221; is crucial. If the straps do not fit well or if a gap forms during work, it is unsafe.</p>
<ul>
<li data-start="270" data-end="315">The straps must be positioned correctly for stability.</li>
<li data-start="318" data-end="356">Adjust the length to ensure a snug fit.</li>
</ul>
<p data-start="22" data-end="57"><strong data-start="22" data-end="57">Uses a Synthetic Rubber Strap</strong></p>
<p data-start="59" data-end="154">The strap absorbs moisture well, feels soft against the skin, and prevents allergic reactions associated with natural rubber.</p>
<p data-start="59" data-end="154"><img loading="lazy" decoding="async" class="aligncenter wp-image-56480" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421.png" sizes="auto, (max-width: 195px) 100vw, 195px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111421-300x274.png 300w" alt="" width="195" height="178" /></p>
<p data-start="156" data-end="243" data-is-last-node="" data-is-only-node="">The strap length can be adjusted while wearing the mask to accommodate different facial sizes.</p>
<p data-start="22" data-end="62"><strong data-start="22" data-end="62">Easy to Wear &#8211; T-Type (Hook Style)</strong></p>
<ul>
<li data-start="66" data-end="83">Does not tangle hair.</li>
<li data-start="86" data-end="122">Adjustable strap length.</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56481" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505.png" sizes="auto, (max-width: 207px) 100vw, 207px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505.png 312w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111505-300x217.png 300w" alt="" width="207" height="150" /></p>
<p data-start="124" data-end="203" data-is-last-node="" data-is-only-node="">Simply pull the strap over the head, wrap it around the sides, and secure it with the hook.</p>
<p data-start="0" data-end="46"><strong data-start="0" data-end="46">Even Softer Wearing Feel (TK Hook Style)</strong></p>
<ul>
<li data-start="50" data-end="67">Does not tangle hair.</li>
<li data-start="70" data-end="121">Adjustable strap length and tension.</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56482" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626.png" sizes="auto, (max-width: 198px) 100vw, 198px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626.png 313w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-111626-300x219.png 300w" alt="" width="198" height="145" /></p>
<p data-start="123" data-end="225" data-is-last-node="" data-is-only-node="">The tightness of the upper and lower straps can be individually adjusted for an optimal fit, reducing pressure on the ears.</p>
<h2 data-start="123" data-end="225">Hi-Luck Series</h2>
<h3 data-path-to-node="9"><b data-path-to-node="9" data-index-in-node="0">Information on Hi-Luck 335 Respirator</b></h3>
<p data-path-to-node="9">DS2 Standard: The Model 330 base equipped with an exhalation valve. This minimizes heat and moisture buildup inside the mask from exhaled breath, making breathing easier.</p>
<p data-path-to-node="9"><img loading="lazy" decoding="async" class="wp-image-56510 aligncenter" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-14_141704-removebg-preview.png" alt="" width="226" height="193" /></p>
<ul>
<li data-path-to-node="10">FF (Free Fit Lip)</li>
<li data-path-to-node="10">Shape Recovery</li>
<li data-path-to-node="10">Exhalation Valve</li>
</ul>
<p data-path-to-node="11"><strong>Standard:</strong> Complies with TM730 certification, Assigned Protection Factor of 10.</p>
<h3><strong data-start="61" data-end="80">Bipromicron Filter </strong>(Models 650, 655)</h3>
<p data-start="99" data-end="285">This is a high-performance filter recycled from the leftover raw materials of molded high-efficiency filters. The filter material is repurposed and processed into a new high-performance filter.</p>
<p data-start="287" data-end="456"><strong>Recycled Material</strong><br data-start="307" data-end="310" />We are effectively utilizing waste as a resource. This is an eco-friendly filter created from recycled filter materials.</p>
<p data-start="287" data-end="456"><img loading="lazy" decoding="async" class=" wp-image-192565 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-300x187.jpg" alt="" width="343" height="214" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-300x187.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1-768x478.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-1.jpg 1024w" sizes="auto, (max-width: 343px) 100vw, 343px" /></p>
<h3 data-start="34" data-end="87"><strong data-start="34" data-end="66">Shape Recovery Structure </strong>(Models 550, 555 excluded)</h3>
<p data-start="89" data-end="274">The inside of the mask is reinforced with a shape-retaining mesh so that it does not lose its form when folded. This ensures the mask maintains its shape even when folded during breaks or short intervals.</p>
<p data-start="276" data-end="289"><strong>Hygiene</strong></p>
<ul>
<li data-start="292" data-end="379">When not in use, you can fold the mask closed to prevent dust from entering the inside of the facepiece.</li>
<li data-start="382" data-end="488">During hot or cold seasons, moisture from breathing may penetrate the mask, but this does not affect its performance.</li>
</ul>
<h3 data-start="34" data-end="162"><strong data-start="34" data-end="63">Completely Incinerable</strong></h3>
<p>The material contains no chloride compounds, so it does not generate toxic gases like dioxins when incinerated.</p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56485" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-113256.png" alt="" width="137" height="164" /></p>
<p><strong data-start="164" data-end="198">Metal-Free Design</strong><br data-start="198" data-end="201" />With the FF Lip design, an excellent seal is achieved without the use of metal parts such as nose clips.</p>
<h3>Features:</h3>
<ul>
<li data-start="36" data-end="124"><strong data-start="36" data-end="42">FF Lip</strong>: The Free Fit Lip design improves airtightness and provides a secure fit to the face.</li>
<li data-start="127" data-end="220"><strong data-start="127" data-end="149">Shape Recovery</strong>: Easily folds away during breaks or transit without losing its structural integrity.</li>
<li data-start="223" data-end="286"><strong data-start="223" data-end="233">Exhalation Valve</strong>: Facilitates easier exhalation and reduces heat buildup.</li>
<li data-start="289" data-end="372"><strong data-start="289" data-end="298">Bipro</strong>: Filter manufactured using recycled materials from ecological sources.</li>
<li data-start="375" data-end="455"><strong data-start="375" data-end="395">Activated Carbon</strong>: Filters out low levels of ozone gas, aiding in air purification.</li>
</ul>
<h3>Performance Specifications</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th class="header-main" colspan="2"><strong>Performance</strong></th>
<th><strong>Model</strong><br />
<strong>350 / 350T</strong></th>
<th><strong>Model</strong><br />
<strong>355 / 355T</strong></th>
<th><strong>Model</strong><br />
<strong>350TK</strong></th>
<th><strong>Model</strong><br />
<strong>355TK</strong></th>
<th><strong>Model</strong><br />
<strong>650 / 650T</strong></th>
<th><strong>Model</strong><br />
<strong>655 / 655T</strong></th>
<th><strong>Model</strong><br />
<strong>550</strong></th>
<th><strong>Model</strong><br />
<strong>555</strong></th>
<th><strong>Model</strong><br />
<strong>330</strong></th>
<th><strong>Model</strong><br />
<strong>335</strong></th>
</tr>
</thead>
<tbody>
<tr>
<th class="row-label" colspan="2"><strong>Particle Collection Efficiency</strong><br />
<strong><span class="small-text">(NaCl particles)</span></strong></th>
<td>95.0% or more<br />
(98.4%)</td>
<td>95.0% or more<br />
(97.9%)</td>
<td>95.0% or more<br />
(98.31%)</td>
<td>95.0% or more<br />
(98.18%)</td>
<td>95.0% or more<br />
(99.4%)</td>
<td>95.0% or more<br />
(99.0%)</td>
<td>80.0% or more<br />
(89.3%)</td>
<td>80.0% or more<br />
(88.6%)</td>
<td>80.0% or more<br />
(89.73%)</td>
<td>95.0% or more<br />
(98.46%)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Inhalation Resistance</strong></th>
<td>50Pa or less<br />
(35Pa)</td>
<td>50Pa or less<br />
(37Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>50Pa or less<br />
(39Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>52Pa or less<br />
(40Pa)</td>
<td>40Pa or less<br />
(29Pa)</td>
<td>43Pa or less<br />
(32Pa)</td>
<td>45Pa or less<br />
(28Pa)</td>
<td>70Pa or less<br />
(50Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Exhalation Resistance</strong></th>
<td>50Pa or less<br />
(35Pa)</td>
<td>36Pa or less<br />
(21Pa)</td>
<td>50Pa or less<br />
(35Pa)</td>
<td>36Pa or less<br />
(21Pa)</td>
<td>50Pa or less<br />
(36Pa)</td>
<td>36Pa or less<br />
(19Pa)</td>
<td>40Pa or less<br />
(29Pa)</td>
<td>28Pa or less<br />
(18Pa)</td>
<td>45Pa or less<br />
(29Pa)</td>
<td>40Pa or less<br />
(22Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Inhalation Resistance Increase</strong></th>
<td>―<br />
(135Pa)</td>
<td>―<br />
(203Pa)</td>
<td>―<br />
(131Pa)</td>
<td>―<br />
(160Pa)</td>
<td>―<br />
(90Pa)</td>
<td>―<br />
(113Pa)</td>
<td>―<br />
(97Pa)</td>
<td>―<br />
(147Pa)</td>
<td>―<br />
(122Pa)</td>
<td>―<br />
(208Pa)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>CO2 Concentration Increase</strong><br />
<strong>/ Dead Space</strong></th>
<td>1.0% or less / 400cm³ or less<br />
(0.45% / 178cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.41% / 165cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.42% / 166cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.39% / 156cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.37% / 149cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.39% / 156cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.73% / 293cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.71% / 283cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.38% / 152cm³)</td>
<td>1.0% or less / 400cm³ or less<br />
(0.34% / 136cm³)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Wet Resistance Value</strong></th>
<td>―<br />
(31Pa)</td>
<td>―<br />
(22Pa)</td>
<td>―<br />
(29Pa)</td>
<td>―<br />
(18Pa)</td>
<td>―<br />
(30Pa)</td>
<td>―<br />
(17Pa)</td>
<td>―<br />
(25Pa)</td>
<td>―<br />
(16Pa)</td>
<td>―<br />
(24Pa)</td>
<td>―<br />
(18Pa)</td>
</tr>
<tr>
<th class="row-label" rowspan="3"><strong>Weight</strong></th>
<th class="row-label"><strong>2-Strap Type</strong></th>
<td>Model 350: 12.1g or less<br />
(9.1g)</td>
<td>Model 355: 14.1g or less<br />
(11.1g)</td>
<td>―</td>
<td>―</td>
<td>Model 650: 12.6g or less<br />
(9.9g)</td>
<td>Model 655: 14.5g or less<br />
(11.8g)</td>
<td>12.3g or less (10.1g)</td>
<td>14.1g or less (11.8g)</td>
<td>―</td>
<td>―</td>
</tr>
<tr>
<th class="row-label"><strong>Hook Type</strong></th>
<td>Model 350T: 12.7g or less<br />
(9.7g)</td>
<td>Model 355T: 14.5g or less<br />
(11.5g)</td>
<td>―</td>
<td>―</td>
<td>Model 650T: 13.1g or less<br />
(10.2g)</td>
<td>Model 655T: 15.0g or less<br />
(12.4g)</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>―</td>
</tr>
<tr>
<th class="row-label"><strong>TK Hook Type</strong></th>
<td>―</td>
<td>―</td>
<td>13.3g or less<br />
(10.4g)</td>
<td>15.3g or less<br />
(12.3g)</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>―</td>
<td>12.5g or less<br />
(9.9g)</td>
<td>14.5g or less<br />
(11.7g)</td>
</tr>
<tr>
<th class="row-label" colspan="2"><strong>Maximum Use Time Limit</strong></th>
<td>13 Hours</td>
<td>15 Hours</td>
<td>13 Hours</td>
<td>15 Hours</td>
<td>20 Hours</td>
<td>25 Hours</td>
<td>12 Hours</td>
<td>13 Hours</td>
<td>10 Hours</td>
<td>8 Hours</td>
</tr>
</tbody>
</table>
<p>Models 350TK, 355TK, 330, and 335 use the TK hook type strap. Models 350T, 355T, 650T, and 655T use the standard hook type strap.<br />
Values in ( ) indicate average values.</p>
<h3 data-start="34" data-end="59"><strong data-start="34" data-end="59">Regarding usage time:</strong></h3>
<p data-start="62" data-end="200">When using a disposable respirator, the maximum use time is specified according to the standards of the Japanese Society of Respiratory Protection Engineers.<br />
When supplied with 0.1g NaCl / minute at an airflow of 40L/minute, the usage time of this respirator will meet the Japanese national standard for dust respirators, until it exceeds 1.5 times the specified value.</p>
<p data-start="62" data-end="200">However, you must replace the mask in the following situations:</p>
<ul>
<li data-start="480" data-end="501">When breathing becomes difficult.</li>
<li data-start="506" data-end="537">When the mask is damaged or heavily soiled.</li>
<li data-start="542" data-end="566">When the mask becomes deformed.</li>
</ul>
<h3 class="table-title">Inward Leakage Rate</h3>
<div class="table-container">
<table>
<thead>
<tr>
<th class="col-subject" rowspan="2"><strong>Test</strong><br />
<strong>Subject</strong></th>
<th><strong>Lip Width (cm)</strong></th>
<th><strong>Nose-Chin Distance (cm)</strong></th>
<th colspan="14"><strong>Leakage Rate (%)</strong></th>
</tr>
<tr>
<th><strong>Specification</strong></th>
<th><strong>Specification</strong></th>
<th><strong>Model</strong><br />
<strong>350</strong></th>
<th><strong>Model</strong><br />
<strong>350T</strong></th>
<th><strong>Model</strong><br />
<strong>355</strong></th>
<th><strong>Model</strong><br />
<strong>355T</strong></th>
<th><strong>Model</strong><br />
<strong>350TK</strong></th>
<th><strong>Model</strong><br />
<strong>355TK</strong></th>
<th><strong>Model</strong><br />
<strong>650</strong></th>
<th><strong>Model</strong><br />
<strong>650T</strong></th>
<th><strong>Model</strong><br />
<strong>655</strong></th>
<th><strong>Model</strong><br />
<strong>655T</strong></th>
<th><strong>Model</strong><br />
<strong>550</strong></th>
<th><strong>Model</strong><br />
<strong>555</strong></th>
<th><strong>Model</strong><br />
<strong>330</strong></th>
<th><strong>Model</strong><br />
<strong>335</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td class="col-subject">A</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">10.5 to<br />
less than 11.5</td>
<td>0.15</td>
<td>0.24</td>
<td>0.18</td>
<td>0.27</td>
<td>0.19</td>
<td>0.30</td>
<td>0.07</td>
<td>0.11</td>
<td>0.47</td>
<td>0.14</td>
<td>1.83</td>
<td>1.63</td>
<td>0.26</td>
<td>0.34</td>
</tr>
<tr>
<td class="col-subject">B</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.42</td>
<td>0.32</td>
<td>0.57</td>
<td>0.41</td>
<td>0.36</td>
<td>0.27</td>
<td>0.08</td>
<td>0.20</td>
<td>0.31</td>
<td>0.36</td>
<td>1.29</td>
<td>1.85</td>
<td>0.57</td>
<td>0.13</td>
</tr>
<tr>
<td class="col-subject">C</td>
<td class="col-dimension">3.5 to<br />
less than 4.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.18</td>
<td>0.19</td>
<td>0.25</td>
<td>0.19</td>
<td>0.38</td>
<td>0.36</td>
<td>0.14</td>
<td>0.26</td>
<td>0.16</td>
<td>0.26</td>
<td>1.43</td>
<td>2.45</td>
<td>1.65</td>
<td>0.24</td>
</tr>
<tr>
<td class="col-subject">D</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">10.5 to<br />
less than 11.5</td>
<td>0.35</td>
<td>0.26</td>
<td>0.27</td>
<td>0.24</td>
<td>0.18</td>
<td>0.29</td>
<td>0.11</td>
<td>0.08</td>
<td>0.34</td>
<td>0.25</td>
<td>1.68</td>
<td>1.88</td>
<td>0.73</td>
<td>0.14</td>
</tr>
<tr>
<td class="col-subject">E</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.58</td>
<td>0.44</td>
<td>0.41</td>
<td>0.37</td>
<td>0.42</td>
<td>0.19</td>
<td>0.21</td>
<td>0.72</td>
<td>0.26</td>
<td>0.86</td>
<td>1.74</td>
<td>1.78</td>
<td>1.06</td>
<td>0.13</td>
</tr>
<tr>
<td class="col-subject">F</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.06</td>
<td>0.17</td>
<td>0.09</td>
<td>0.11</td>
<td>0.14</td>
<td>0.48</td>
<td>0.37</td>
<td>0.22</td>
<td>0.38</td>
<td>0.39</td>
<td>1.98</td>
<td>1.37</td>
<td>1.53</td>
<td>0.56</td>
</tr>
<tr>
<td class="col-subject">G</td>
<td class="col-dimension">4.5 to<br />
less than 5.5</td>
<td class="col-dimension">13.5 to<br />
less than 14.5</td>
<td>0.09</td>
<td>0.05</td>
<td>0.08</td>
<td>0.12</td>
<td>0.35</td>
<td>0.57</td>
<td>0.11</td>
<td>0.27</td>
<td>0.59</td>
<td>0.70</td>
<td>1.22</td>
<td>1.95</td>
<td>1.33</td>
<td>0.62</td>
</tr>
<tr>
<td class="col-subject">H</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">11.5 to<br />
less than 12.5</td>
<td>0.15</td>
<td>0.07</td>
<td>0.25</td>
<td>0.13</td>
<td>0.12</td>
<td>0.55</td>
<td>0.07</td>
<td>0.19</td>
<td>0.20</td>
<td>0.33</td>
<td>1.35</td>
<td>1.98</td>
<td>2.33</td>
<td>0.32</td>
</tr>
<tr>
<td class="col-subject">I</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">12.5 to<br />
less than 13.5</td>
<td>0.12</td>
<td>0.14</td>
<td>0.15</td>
<td>0.17</td>
<td>0.21</td>
<td>0.44</td>
<td>0.14</td>
<td>0.08</td>
<td>0.41</td>
<td>0.64</td>
<td>1.45</td>
<td>1.78</td>
<td>2.02</td>
<td>0.39</td>
</tr>
<tr>
<td class="col-subject">J</td>
<td class="col-dimension">5.5 to<br />
less than 6.5</td>
<td class="col-dimension">13.5 to<br />
less than 14.5</td>
<td>0.41</td>
<td>0.35</td>
<td>0.27</td>
<td>0.19</td>
<td>0.48</td>
<td>0.45</td>
<td>0.39</td>
<td>0.05</td>
<td>0.15</td>
<td>0.20</td>
<td>2.27</td>
<td>2.04</td>
<td>1.76</td>
<td>0.35</td>
</tr>
</tbody>
</table>
</div>
</div>The post <a href="https://koueitrading.com/global/product/koken-hi-luck-335-disposable-dust-mask/">Koken Hi-Luck 335 Disposable Dust Mask</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken Dust Mask Options</title>
		<link>https://koueitrading.com/global/product/koken-dust-mask-options/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 12 Mar 2020 04:21:49 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192555</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Important points when wearing a respirator Dust respirators use high-efficiency filters to prevent the inhalation of hazardous dust. To protect yourself from inhaling dust when wearing a dust respirator, the performance of this filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are extremely important. 1. Filter Technology with [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-dust-mask-options/">Koken Dust Mask Options</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.</p>
<h2>Important points when wearing a respirator</h2>
<p>Dust respirators use high-efficiency filters to prevent the inhalation of hazardous dust. To protect yourself from inhaling dust when wearing a dust respirator, the performance of this filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are extremely important.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Through unique technology, the sheep wool is electrostatically charged, and this electrostatic force draws particles to the fiber surface. This is the primary mechanism for collecting particles. A high-density fiber structure is not required, thus integrating the two contrasting features of &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221;</p>
<p>It consistently maintains the highest standard of performance and quality, and has been utilized for a long time as an outstanding filter.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" sizes="auto, (max-width: 317px) 100vw, 317px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png 317w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333-300x204.png 300w" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" sizes="auto, (max-width: 316px) 100vw, 316px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png 316w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322-300x227.png 300w" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applicable products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the filter&#8217;s fiber density improves collection efficiency. To meet airflow resistance standards, paper filters require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into a pristine circular shape in a single process to create the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" sizes="auto, (max-width: 329px) 100vw, 329px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751-300x116.png 300w" alt="" width="329" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" sizes="auto, (max-width: 321px) 100vw, 321px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png 321w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803-300x227.png 300w" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applicable products are from P.8 to P.11</p>
<p data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to national assay standards based on national regulations. The contents of these standards are comprehensive, ensuring the manufacture of products that meet strict safety requirements.</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td width="64">In addition to JIS standards, dust respirators are tested according to national assay standards based on national regulations. The contents of these standards are comprehensive, ensuring the manufacture of products that meet strict safety requirements.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the &#8220;Dust Respirator Standards&#8221;.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Aerosol</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride) particles</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate) particles</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ/min</td>
<td class="text-center" colspan="2">85 ℓ/min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement, must meet the value in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" colspan="2">For NaCl test aerosol<br />
Loaded up to 100mg</td>
<td class="text-left" colspan="2">For DOP test aerosol<br />
Loaded up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or more</td>
<td>RL1</td>
<td class="text-center">80.0% or more</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or more</td>
<td>RL2</td>
<td class="text-center">95.0% or more</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or more</td>
<td>RL3</td>
<td class="text-center">99.9% or more</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or more</td>
<td>DL1</td>
<td class="text-center">80.0% or more</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or more</td>
<td>DL2</td>
<td class="text-center">95.0% or more</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or more</td>
<td>DL3</td>
<td class="text-center">99.9% or more</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>( ) indicates products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col">Exhalation valve operation leak test</td>
<td>&#8211; When air is drawn, the internal pressure must decrease immediately<br />
&#8211; The time for internal pressure to return to normal atmospheric pressure must be 15 seconds or more</td>
</tr>
<tr>
<th class="header-col"><strong>Carbon Dioxide (CO2) Concentration Increase</strong></th>
<td class="content-col" colspan="2">Using a test headform and an artificial lung to inhale/exhale air containing CO2. The difference in CO2 concentration in the inhaled air between wearing and not wearing the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space Volume</strong></th>
<td class="content-col" colspan="2">Calculated from the (Carbon Dioxide Concentration Increase Test)</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Aerosol</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">Measured at 40 ℓ/min after loading test dust at 85 ℓ/min</td>
</tr>
<tr>
<td class="header-sub">Amount loaded onto dust respirator</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Aerosol and Collection Efficiency </span><span class="bottom-left-text">Disposable Type<br />
/ Replaceable Type</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" rowspan="2"><strong>Classification</strong><br />
<strong>(Particle Collection Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender"><strong>Test aerosol is solid Sodium Chloride (NaCl)</strong></th>
<th class="bg-lavender"><strong>Test aerosol is liquid Dioctyl Phthalate (DOP)</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
</tbody>
</table>
<h2>High-Performance Filter + Facepiece Designed for Easy Fit</h2>
<h3>2. Facepiece Fit Technology</h3>
<p>Even if a dust respirator has a high collection efficiency filter, it is meaningless if dust leaks through the face-to-mask seal during use. This is primarily caused by a &#8220;gap at the face contact area when worn.&#8221;</p>
<p>We consider mask fit to be just as important as filter performance. Therefore, our company has long developed technologies to enhance the airtightness of the facepiece seal.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" sizes="auto, (max-width: 247px) 100vw, 247px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg 775w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-227x300.jpg 227w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-768x1015.jpg 768w" alt="" width="247" height="326" /></p>
<p><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and effortlessly adapts to facial movements, ensuring a comfortable fit. The material also remains stable during use.</p>
<p><strong>HAWC Lip Structure</strong><br />
The lip design ensures a high degree of adhesion, maximizing the &#8220;suction cup&#8221; effect when wearing the mask to ensure an airtight facial seal.<img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" sizes="auto, (max-width: 145px) 100vw, 145px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png 319w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014-267x300.png 267w" alt="" width="145" height="163" /></p>
<p><strong>Free Position Under Chin</strong><br />
The unique curve of the face contact area prevents dust from leaking in. By aligning the nose portion first, it accommodates various facial dimensions, providing a secure fit for a wide range of face sizes (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" sizes="auto, (max-width: 192px) 100vw, 192px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png 410w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024-300x180.png 300w" alt="" width="192" height="115" /></p>
<p><strong data-start="56" data-end="112">Fit Status of the Free Position Under Chin Mask</strong><br data-start="112" data-end="115" />(Simulated image with the mask cut away to clearly show where it contacts the chin).</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong data-start="56" data-end="94">For individuals with large faces:</strong><br data-start="94" data-end="97" />The outer section of the mask rests naturally against the chin to provide a proper fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td width="64"><strong data-start="164" data-end="202">For individuals with small faces:</strong><br data-start="202" data-end="205" />The inner section of the mask naturally positions itself against the chin to secure the fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Wearing Stability</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Built-in Fit Checker</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed to naturally conform to various facial sizes and shapes, providing a seamless fit.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Uses a 3D-shaped polyband harness that conforms to the shape of the head, cradling it to enhance fit and sealing performance.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>A built-in fit checker allows you to test the mask&#8217;s seal at any time (available for the 1005, 1010A, 1015, and 1180 series).</td>
</tr>
</tbody>
</table>
<h2 data-start="91" data-end="595">Optional Accessories (Replaceable Dust Respirators)</h2>
<h3 data-path-to-node="1"><b data-path-to-node="1" data-index-in-node="0">Moisture Sponge</b></h3>
<p data-path-to-node="2">Use this when you feel discomfort due to moisture (sweat, breath condensation) accumulating inside the mask. (Disposable type)</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><strong>Egg-shaped Moisture Sponge</strong> (50 pcs/pack)</td>
<td style="width: 48pt;" width="64"><strong>Type A Moisture Sponge</strong> (For Bonnet types) (10 pcs/pack)</td>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><img loading="lazy" decoding="async" class="aligncenter wp-image-56513" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-14_142732-removebg-preview.png" alt="" width="162" height="173" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56514" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-14_142728-removebg-preview.png" alt="" width="301" height="163" /></td>
</tr>
</tbody>
</table>
<h3><strong>Inhalation Port Cover</strong></h3>
<p>This cover minimizes the direct entry of flying objects into the filter. It is suitable for tasks generating significant spatter (welding slag) or sparks.</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56515" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-14_142955-removebg-preview.png" alt="" width="255" height="230" /></td>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><strong>Inhalation Port Cover</strong> (2 pcs/pack).</td>
</tr>
</tbody>
</table>
<p><b data-path-to-node="3,1,0" data-index-in-node="17">Cannot be attached to the following models:</b> 1005 Series, 1010A, Model 1015, Hi-Luck Series.</p>
<h3>Visor Cover (Lens Protector)</h3>
<p>This cover protects the mask&#8217;s visor lens from scratches and dust accumulation.</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56517" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-143701.png" alt="" width="305" height="280" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-192560" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-1-300x286.jpg" alt="" width="300" height="286" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-1-300x286.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-1-768x733.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-1.jpg 1024w" sizes="auto, (max-width: 300px) 100vw, 300px" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56518" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-143727.png" alt="" width="303" height="287" /></td>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><strong>Visor Cover for H-VII</strong> (10 pcs/pack)<br />
Compatible models: Model 1521H, 1521U.</td>
<td><strong>Visor Cover for H-VII Type A</strong> (10 pcs/pack)<br />
Compatible models: Model 1521H, 1521U.</td>
<td><strong>Visor Cover for HV</strong> (5 pcs/pack)<br />
Compatible models: Model 1721H, 1781DW, 1781DWC.</td>
</tr>
</tbody>
</table>
<h3>Dedicated Glasses for Full-Face Masks</h3>
<p>If you require vision correction (e.g., for nearsightedness/farsightedness), the use of these dedicated glasses is mandatory.</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56520" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-143844.png" alt="" width="434" height="348" /></td>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><strong>Glasses for High Scope V Series</strong><br />
Compatible models: Model 1721H, 1781DW, 1781DWC.</td>
</tr>
</tbody>
</table>
<h3>Dedicated Glasses Clip for Full-Face Masks</h3>
<p>For the High Scope VII series masks, you can wear your everyday prescription glasses by combining them with this dedicated glasses clip.</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56519" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-14_143852-removebg-preview.png" alt="" width="417" height="340" /></td>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><strong>Glasses Clip Type A</strong><br />
Compatible models: Model 1521H, 1521U.</td>
</tr>
</tbody>
</table>
<h3>Fit Test Adapter</h3>
<p>Used when conducting quantitative fit testing with measurement equipment.<br />
*Please use the dedicated sampling adapter corresponding to each specific mask model.</p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56521" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-144223.png" alt="" width="660" height="219" /></p>
<h3>KBC Filter</h3>
<p>This is an auxiliary filter that removes Ozone odors generated during welding and neutralizes odors from organic solvents (at levels below the permissible limit).</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56522" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-144500.png" alt="" width="303" height="115" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56523" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-144508.png" alt="" width="248" height="115" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56524" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-14-144520.png" alt="" width="245" height="110" /></td>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><b data-path-to-node="3,0,0" data-index-in-node="0">KBC Filter for 1005 Series<br />
</b>Compatible models: Model 1005RR, 1005RRX.</td>
<td><b data-path-to-node="3,1,0" data-index-in-node="0">KBC Filter for 1021/1091 Series<br />
</b>Compatible models: Model 1021R, 1021RX, 1091D.</td>
<td><b data-path-to-node="3,2,0" data-index-in-node="0">KBC Filter for 1121/1191 Series<br />
</b>Compatible models: Model 1121R, 1121RX, 1191SD, 1191D, 1122R.</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/koken-dust-mask-options/">Koken Dust Mask Options</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken Dust Mask Replacement Parts</title>
		<link>https://koueitrading.com/global/product/koken-dust-mask-replacement-parts/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 12 Mar 2020 04:11:40 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192550</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Important points when wearing a respirator Dust respirators use high-efficiency filters to prevent the inhalation of hazardous dust. To protect yourself from inhaling dust when wearing a dust respirator, the performance of this filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are extremely important. 1. Filter Technology with [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-dust-mask-replacement-parts/">Koken Dust Mask Replacement Parts</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.</p>
<h2>Important points when wearing a respirator</h2>
<p>Dust respirators use high-efficiency filters to prevent the inhalation of hazardous dust. To protect yourself from inhaling dust when wearing a dust respirator, the performance of this filter and the &#8220;tight seal&#8221; (fit) between the mask and your face are extremely important.</p>
<h3>1. Filter Technology with High Particle Collection Efficiency</h3>
<p><strong>Mighty (Uni) Micron Filter</strong><br data-start="306" data-end="309" />Through unique technology, the sheep wool is electrostatically charged, and this electrostatic force draws particles to the fiber surface. This is the primary mechanism for collecting particles. A high-density fiber structure is not required, thus integrating the two contrasting features of &#8220;high collection efficiency&#8221; and &#8220;low inhalation resistance.&#8221;</p>
<p>It consistently maintains the highest standard of performance and quality, and has been utilized for a long time as an outstanding filter.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56353" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png" sizes="auto, (max-width: 317px) 100vw, 317px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333.png 317w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153333-300x204.png 300w" alt="" width="317" height="216" /></td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56352" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png" sizes="auto, (max-width: 316px) 100vw, 316px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322.png 316w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153322-300x227.png 300w" alt="" width="316" height="239" /></td>
</tr>
</tbody>
</table>
<p>Applicable products are on P.4 ~ 6, P.11</p>
<p><strong>Alpha Ring Filter</strong></p>
<p data-start="57" data-end="197">Increasing the filter&#8217;s fiber density improves collection efficiency. To meet airflow resistance standards, paper filters require an expanded surface area.</p>
<p data-start="199" data-end="490">For the first time in Japan, ultra-fine fibers were formed into a pristine circular shape in a single process to create the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.</p>
<table border="0" width="128" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56354" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png" sizes="auto, (max-width: 329px) 100vw, 329px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751.png 329w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153751-300x116.png 300w" alt="" width="329" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56355" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png" sizes="auto, (max-width: 321px) 100vw, 321px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803.png 321w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-153803-300x227.png 300w" alt="" width="321" height="243" /></td>
</tr>
</tbody>
</table>
<p>Applicable products are from P.8 to P.11</p>
<p data-start="46" data-end="81"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></p>
<p data-start="83" data-end="308">In addition to JIS standards, dust respirators are tested according to national assay standards based on national regulations. The contents of these standards are comprehensive, ensuring the manufacture of products that meet strict safety requirements.</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong data-start="46" data-end="81">Dust Respirator Standards</strong></th>
<td width="64">In addition to JIS standards, dust respirators are tested according to national assay standards based on national regulations. The contents of these standards are comprehensive, ensuring the manufacture of products that meet strict safety requirements.</td>
</tr>
</tbody>
</table>
<p>Note: The table below is excerpted from the &#8220;Dust Respirator Standards&#8221;.</p>
<table class="mask-table">
<tbody>
<tr>
<th class="bg-gray" rowspan="2"><strong>Replaceable Dust Respirator</strong></th>
<td class="bg-white">Isolation Type Dust Respirator</td>
</tr>
<tr>
<td class="bg-white">Direct Connection Type Dust Respirator</td>
</tr>
<tr>
<th class="bg-gray" colspan="2"><strong>Disposable Dust Respirator</strong></th>
</tr>
</tbody>
</table>
<table class="standard-table">
<tbody>
<tr>
<th class="bg-blue" rowspan="3"><strong>Test Aerosol</strong></th>
<th class="bg-gray col-type"><strong>Type</strong></th>
<td class="text-center" colspan="2">NaCl (Sodium Chloride) particles</td>
<td class="text-center" colspan="2">DOP (Dioctyl Phthalate) particles</td>
</tr>
<tr>
<th class="bg-gray"><strong>Particle Size</strong></th>
<td class="text-center" colspan="2">0.06 μm to 0.1 μm</td>
<td class="text-center" colspan="2">0.15 μm to 0.25 μm</td>
</tr>
<tr>
<th class="bg-gray"><strong>Concentration</strong></th>
<td class="text-center" colspan="2">50mg/m³ or less</td>
<td class="text-center" colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="bg-blue" colspan="2"><strong>Test Flow Rate</strong></th>
<td class="text-center" colspan="2">85 ℓ/min</td>
<td class="text-center" colspan="2">85 ℓ/min</td>
</tr>
<tr>
<th class="bg-blue" rowspan="7"><strong>Particle Collection Efficiency</strong><br />
<strong>(Continuous measurement, must meet the value in the right column)</strong></th>
<th class="bg-gray"></th>
<td class="text-left" colspan="2">For NaCl test aerosol<br />
Loaded up to 100mg</td>
<td class="text-left" colspan="2">For DOP test aerosol<br />
Loaded up to 200mg</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Replaceable</strong><br />
<strong>Type</strong></th>
<td>RS1</td>
<td class="text-center">80.0% or more</td>
<td>RL1</td>
<td class="text-center">80.0% or more</td>
</tr>
<tr>
<td>RS2</td>
<td class="text-center">95.0% or more</td>
<td>RL2</td>
<td class="text-center">95.0% or more</td>
</tr>
<tr>
<td>RS3</td>
<td class="text-center">99.9% or more</td>
<td>RL3</td>
<td class="text-center">99.9% or more</td>
</tr>
<tr>
<th class="bg-gray" rowspan="3"><strong>Disposable</strong><br />
<strong>Type</strong></th>
<td>DS1</td>
<td class="text-center">80.0% or more</td>
<td>DL1</td>
<td class="text-center">80.0% or more</td>
</tr>
<tr>
<td>DS2</td>
<td class="text-center">95.0% or more</td>
<td>DL2</td>
<td class="text-center">95.0% or more</td>
</tr>
<tr>
<td>DS3</td>
<td class="text-center">99.9% or more</td>
<td>DL3</td>
<td class="text-center">99.9% or more</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Inhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">80Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">160Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">150Pa or less (100Pa or less)</td>
</tr>
<tr>
<th class="bg-blue" rowspan="4"><strong>Exhalation Resistance</strong><br />
<strong>(Test flow rate 40 ℓ/min)</strong></th>
<th class="bg-gray" colspan="3"><strong>Replaceable Type</strong></th>
<th class="bg-gray" colspan="2"><strong>Disposable Type</strong></th>
</tr>
<tr>
<td colspan="2">RS1　RL1</td>
<td class="text-center">70Pa or less</td>
<td>DS1　DL1</td>
<td class="text-center">60Pa or less (45Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS2　RL2</td>
<td class="text-center">70Pa or less</td>
<td>DS2　DL2</td>
<td class="text-center">70Pa or less (50Pa or less)</td>
</tr>
<tr>
<td colspan="2">RS3　RL3</td>
<td class="text-center">80Pa or less</td>
<td>DS3　DL3</td>
<td class="text-center">80Pa or less (100Pa or less)</td>
</tr>
</tbody>
</table>
<p>( ) indicates products without an exhalation valve.</p>
<table>
<tbody>
<tr>
<th class="header-col"><strong>Exhalation Valve Airtightness</strong></th>
<td class="content-col">Exhalation valve operation leak test</td>
<td>&#8211; When air is drawn, the internal pressure must decrease immediately<br />
&#8211; The time for internal pressure to return to normal atmospheric pressure must be 15 seconds or more</td>
</tr>
<tr>
<th class="header-col"><strong>Carbon Dioxide (CO2) Concentration Increase</strong></th>
<td class="content-col" colspan="2">Using a test headform and an artificial lung to inhale/exhale air containing CO2. The difference in CO2 concentration in the inhaled air between wearing and not wearing the mask must be 1.0% or less.</td>
</tr>
<tr>
<th class="header-col"><strong>Dead Space Volume</strong></th>
<td class="content-col" colspan="2">Calculated from the (Carbon Dioxide Concentration Increase Test)</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="header-main" rowspan="3"><strong>Inhalation Resistance Increase</strong></th>
<td class="header-sub">Test Aerosol</td>
<td class="content-col">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<td class="header-sub">Test Flow Rate</td>
<td class="content-col">Measured at 40 ℓ/min after loading test dust at 85 ℓ/min</td>
</tr>
<tr>
<td class="header-sub">Amount loaded onto dust respirator</td>
<td class="content-col">100mg</td>
</tr>
</tbody>
</table>
<table class="spec-table">
<tbody>
<tr>
<th class="diagonal-cell" colspan="2" rowspan="2">
<div class="diagonal-line"></div>
<p><strong><span class="top-right-text">Test Aerosol and Collection Efficiency </span><span class="bottom-left-text">Disposable Type<br />
/ Replaceable Type</span></strong></th>
<th class="bg-lavender big-letter"><strong>S</strong></th>
<th class="bg-lavender big-letter"><strong>L</strong></th>
<th class="bg-lavender" rowspan="2"><strong>Classification</strong><br />
<strong>(Particle Collection Efficiency)</strong></th>
</tr>
<tr>
<th class="bg-lavender"><strong>Test aerosol is solid Sodium Chloride (NaCl)</strong></th>
<th class="bg-lavender"><strong>Test aerosol is liquid Dioctyl Phthalate (DOP)</strong></th>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>R</strong></th>
<th class="bg-gray" rowspan="3"><strong>Replaceable Dust Respirator</strong></th>
<td>RS1</td>
<td>RL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>RS2</td>
<td>RL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>RS3</td>
<td>RL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
<tr>
<th class="bg-gray big-type-letter" rowspan="3"><strong>D</strong></th>
<th class="bg-gray" rowspan="3"><strong>Disposable Dust Respirator</strong></th>
<td>DS1</td>
<td>DL1</td>
<td>Class 1 (80.0% or more)</td>
</tr>
<tr>
<td>DS2</td>
<td>DL2</td>
<td>Class 2 (95.0% or more)</td>
</tr>
<tr>
<td>DS3</td>
<td>DL3</td>
<td>Class 3 (99.9% or more)</td>
</tr>
</tbody>
</table>
<h2>High-Performance Filter + Facepiece Designed for Easy Fit</h2>
<h3>2. Facepiece Fit Technology</h3>
<p>Even if a dust respirator has a high collection efficiency filter, it is meaningless if dust leaks through the face-to-mask seal during use. This is primarily caused by a &#8220;gap at the face contact area when worn.&#8221;</p>
<p>We consider mask fit to be just as important as filter performance. Therefore, our company has long developed technologies to enhance the airtightness of the facepiece seal.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56356" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg" sizes="auto, (max-width: 247px) 100vw, 247px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10.jpg 775w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-227x300.jpg 227w, https://koueitrading.com/vn/wp-content/uploads/2026/01/unnamed-10-768x1015.jpg 768w" alt="" width="247" height="326" /></p>
<p><strong>Silicone Facepiece</strong><br />
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and effortlessly adapts to facial movements, ensuring a comfortable fit. The material also remains stable during use.</p>
<p><strong>HAWC Lip Structure</strong><br />
The lip design ensures a high degree of adhesion, maximizing the &#8220;suction cup&#8221; effect when wearing the mask to ensure an airtight facial seal.<img loading="lazy" decoding="async" class="aligncenter wp-image-56357" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png" sizes="auto, (max-width: 145px) 100vw, 145px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014.png 319w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160014-267x300.png 267w" alt="" width="145" height="163" /></p>
<p><strong>Free Position Under Chin</strong><br />
The unique curve of the face contact area prevents dust from leaking in. By aligning the nose portion first, it accommodates various facial dimensions, providing a secure fit for a wide range of face sizes (see image below).</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56358" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png" sizes="auto, (max-width: 192px) 100vw, 192px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024.png 410w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160024-300x180.png 300w" alt="" width="192" height="115" /></p>
<p><strong data-start="56" data-end="112">Fit Status of the Free Position Under Chin Mask</strong><br data-start="112" data-end="115" />(Simulated image with the mask cut away to clearly show where it contacts the chin).</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><strong data-start="56" data-end="94">For individuals with large faces:</strong><br data-start="94" data-end="97" />The outer section of the mask rests naturally against the chin to provide a proper fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56359" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160213.png" alt="" width="191" height="236" /></td>
<td width="64"><strong data-start="164" data-end="202">For individuals with small faces:</strong><br data-start="202" data-end="205" />The inner section of the mask naturally positions itself against the chin to secure the fit.</td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56360" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160221.png" alt="" width="179" height="215" /></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>FF Lip</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Wearing Stability</strong></th>
<th class="xl65" colspan="2" width="128"><strong>Built-in Fit Checker</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56361" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160333.png" alt="" width="278" height="251" /></td>
<td>Designed to naturally conform to various facial sizes and shapes, providing a seamless fit.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56362" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160346.png" alt="" width="243" height="234" /></td>
<td>Uses a 3D-shaped polyband harness that conforms to the shape of the head, cradling it to enhance fit and sealing performance.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56363" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-08-160353.png" alt="" width="229" height="224" /></td>
<td>A built-in fit checker allows you to test the mask&#8217;s seal at any time (available for the 1005, 1010A, 1015, and 1180 series).</td>
</tr>
</tbody>
</table>
<h2>Replacement Parts (Replaceable Dust Respirators)</h2>
<p>Please ensure safe usage by replacing parts periodically and performing proper cleaning/maintenance.<br />
Replacement parts and optional accessories vary depending on the mask model; please refer to the specific product page for details.</p>
<h3>Inhalation Valve</h3>
<p><img loading="lazy" decoding="async" class=" wp-image-192552 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-1-300x276.jpg" alt="" width="249" height="229" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-1-300x276.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-1-768x707.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-1.jpg 1024w" sizes="auto, (max-width: 249px) 100vw, 249px" /></p>
<h3>Exhalation Valve</h3>
<p><img loading="lazy" decoding="async" class="size-medium wp-image-192553 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-2-300x204.jpg" alt="" width="300" height="204" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-2-300x204.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-2-768x523.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-2.jpg 1024w" sizes="auto, (max-width: 300px) 100vw, 300px" /></p>
<p>Since dust and dirt can easily adhere to the exhalation valve, please inspect its condition frequently. If the exhalation valve is not functioning properly (e.g., gap, stuck), dust may leak into the mask through it.</p>
<h3>Headband (Harness)</h3>
<p>Depending on the frequency of use, if the headband becomes stretched or dirty, please replace it with a new one.</p>
<p><img loading="lazy" decoding="async" class=" wp-image-192551 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-3-1-300x132.jpg" alt="" width="418" height="184" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-3-1-300x132.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-3-1-768x338.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-3-1.jpg 1024w" sizes="auto, (max-width: 418px) 100vw, 418px" /></p>The post <a href="https://koueitrading.com/global/product/koken-dust-mask-replacement-parts/">Koken Dust Mask Replacement Parts</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken BL-711 Series P-PAPR</title>
		<link>https://koueitrading.com/global/product/koken-bl-711-series-p-papr/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 12 Mar 2020 03:51:51 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192544</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: BL-711 Series P-PAPR: Powered Air-Purifying Particulate Respirator PARTICULATE PAPR and GAS PAPR PAPR: Powered Air-Purifying Respirator. P-PAPR: Particulate PAPR (Used for dust/particles). G-PAPR: Gas PAPR (Used for toxic gases/vapors). Within the PAPR range, there are “Powered Air-Purifying Particulate Respirators (P-PAPR)” for dust hazards and “Powered Air-Purifying Gas Respirators (G-PAPR)” for toxic [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-bl-711-series-p-papr/">Koken BL-711 Series P-PAPR</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: BL-711 Series</p>
<p>P-PAPR: Powered Air-Purifying Particulate Respirator</p>
<h2>PARTICULATE PAPR and GAS PAPR</h2>
<ul>
<li data-path-to-node="14,0,0">PAPR: Powered Air-Purifying Respirator.</li>
<li data-path-to-node="14,1,0">P-PAPR: Particulate PAPR (Used for dust/particles).</li>
<li data-path-to-node="14,2,0">G-PAPR: Gas PAPR (Used for toxic gases/vapors).</li>
</ul>
<p data-path-to-node="3">Within the PAPR range, there are “Powered Air-Purifying Particulate Respirators (P-PAPR)” for dust hazards and “Powered Air-Purifying Gas Respirators (G-PAPR)” for toxic gas hazards. It is essential to understand the properties, type, and concentration of the hazardous substances before selecting the appropriate mask.</p>
<p data-path-to-node="3">To prevent inhalation of DUST -&gt; Use a Powered Air-Purifying Particulate Respirator (P-PAPR)<br />
To prevent inhalation of TOXIC GAS -&gt; Use a Powered Air-Purifying Gas Respirator (G-PAPR)<br />
To prevent inhalation of MIXED DUST &amp; TOXIC GAS -&gt; Use a Powered Air-Purifying Gas Respirator (G-PAPR) with dust protection function</p>
<h3>Environments where PAPR CANNOT be used</h3>
<p data-path-to-node="9">PAPR must not be used if any of the following conditions apply. Please use respiratory protective equipment suitable for the environment, such as a supplied-air respirator or a self-contained breathing apparatus (SCBA).</p>
<ul>
<li data-path-to-node="10,0,0">Oxygen-deficient environments or those at risk of oxygen deficiency (Oxygen concentration below 18%).</li>
<li data-path-to-node="10,1,0">Cases where the type or concentration of the toxic gas is unknown.</li>
<li data-path-to-node="10,2,0">IDLH environments (Atmospheres Immediately Dangerous to Life or Health).</li>
<li data-path-to-node="10,2,0">Cases where the toxic gas concentration exceeds the permissible limit for the PAPR. ※</li>
<li data-path-to-node="10,3,0">Cases where no filter (canister) is available to remove the specific toxic gas in the environment.</li>
<li data-path-to-node="10,4,0">Cases where a mixture of gases with different properties exists.</li>
<li data-path-to-node="10,5,0">Cases where the environment deviates significantly from normal temperature, humidity, and atmospheric pressure.</li>
</ul>
<p data-path-to-node="11">(※ According to standards based on the Industrial Safety and Health Act, the application range of G-PAPR is 2% (3% for Ammonia))</p>
<h3>SELECTING THE APPROPRIATE PAPR BASED ON HAZARD CONCENTRATION</h3>
<p data-path-to-node="3">Determine the Required Protection Factor, then select a PAPR model with an Assigned Protection Factor higher than that value.</p>
<p data-path-to-node="4,0">Formula: How to calculate the Required Protection Factor<br />
<strong>Required Protection Factor = Ambient concentration of identified hazard / Permissible exposure limit of the hazard</strong></p>
<p>Assigned Protection Factor of P-PAPR</p>
<table>
<thead>
<tr>
<th colspan="2"><strong>Classification</strong></th>
<th colspan="4"><strong>Facepiece Type</strong></th>
</tr>
<tr>
<th><strong>Leakage Rate</strong></th>
<th><strong>Filter Efficiency</strong></th>
<th><strong>Half-face</strong></th>
<th><strong>Full-face</strong></th>
<th><strong>Hood Type</strong></th>
<th><strong>Face shield</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td rowspan="3">Class S</td>
<td>PL3/PS3</td>
<td>50/300</td>
<td>1000</td>
<td>25/1000</td>
<td>25/300</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>—</td>
<td>—</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td rowspan="3">Class A</td>
<td>PL3/PS3</td>
<td>—</td>
<td>—</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>33</td>
<td>90</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>14</td>
<td>19</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td rowspan="3">Class B</td>
<td>PL3/PS3</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>14</td>
<td>19</td>
<td>11</td>
<td>11</td>
</tr>
</tbody>
</table>
<p>Assigned Protection Factor of G-PAPR</p>
<table>
<thead>
<tr>
<th class="header-main" colspan="4"><strong>Facepiece Type</strong></th>
</tr>
<tr>
<th><strong>Half-face</strong></th>
<th><strong>Full-face</strong></th>
<th><strong>Hood Type</strong></th>
<th><strong>Face shield</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>50/300</td>
<td>1000</td>
<td>25/1000</td>
<td>25/300</td>
</tr>
</tbody>
</table>
<p>For “G-PAPR with dust protection function,” please refer to the Assigned Protection Factor of P-PAPR (Class S leakage rate) mentioned above for dust (and similar particulates).</p>
<h2>TASKS WHERE PAPR USE IS MANDATORY BY REGULATION OR DIRECTIVE</h2>
<p><strong>For tasks where PAPR use is mandatory by regulation or directive, please use a PAPR with the designated performance classification.</strong></p>
<h4><strong>1. Tunnel Construction Work</strong></h4>
<p><strong>Regulation:</strong> “Ordinance on Prevention of Pneumoconiosis”<br />
<strong>Scope:</strong> In tunnel construction, at locations involving “mechanical/powered excavation,” “mechanical loading or unloading of ore/rock,” and “shotcreting.”</p>
<p><strong>PAPR Requirements:</strong></p>
<ul>
<li>National test certified product (High airflow type).</li>
<li>Tight-fitting facepiece type where the battery can be removed for use during blasting operations.</li>
</ul>
<h4><strong>2. Asbestos Removal Work</strong></h4>
<p><strong>Regulation:</strong> “Ordinance on Prevention of Health Impairment due to Asbestos”<br />
<strong>Scope</strong>: In asbestos removal tasks, specifically those requiring “Class 1 Asbestos Removal Masks.”<br />
<b data-path-to-node="11,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified tight-fitting or hood types (High airflow, Class S, PL3 or PS3).</p>
<h4 data-path-to-node="12"><b data-path-to-node="12" data-index-in-node="0">3. Handling Nanomaterials</b></h4>
<p data-path-to-node="13,0,0"><b data-path-to-node="13,0,0" data-index-in-node="0">Directive:</b> “Regarding Preventive Measures for Exposure to Nanomaterials”<br />
<b data-path-to-node="13,1,0" data-index-in-node="0">Scope:</b> Manufacturing and handling of nanomaterials. (※)<br />
<b data-path-to-node="13,2,0" data-index-in-node="0">PAPR Requirements:</b></p>
<ul>
<li data-path-to-node="13,2,0">National test certified product (High airflow, PL3 or PS3).</li>
<li data-path-to-node="13,2,1,0,0">Shape limitations based on the projected exposure levels of workers.</li>
</ul>
<p data-path-to-node="13,2,1,1,0">(※) Depending on the work environment, respiratory protective equipment other than PAPR may be used.</p>
<h4 data-path-to-node="14"><b data-path-to-node="14" data-index-in-node="0">4. Handling Indium</b></h4>
<p data-path-to-node="15,0,0"><b data-path-to-node="15,0,0" data-index-in-node="0">Directive:</b> “Regarding Thorough Health Hazard Prevention Measures for Indium/Tin Oxide Handling”<br />
<b data-path-to-node="15,1,0" data-index-in-node="0">Scope:</b> Handling of Indium, Tin Oxide, etc. (※)<br />
<b data-path-to-node="15,2,0" data-index-in-node="0">PAPR Requirements:</b></p>
<ul>
<li data-path-to-node="15,2,0">National test certified product (High airflow, PL3 or PS3).</li>
<li data-path-to-node="15,2,1,0,0">Limitations on shape and leakage rate based on working environment measurement results.</li>
</ul>
<p data-path-to-node="15,2,1,1,0">(※) Depending on environmental results, respiratory protective equipment other than PAPR may be used.</p>
<h4 data-path-to-node="16"><b data-path-to-node="16" data-index-in-node="0">5. Handling Dioxins</b></h4>
<p><b data-path-to-node="17,0,0" data-index-in-node="0">Directive:</b> “Revision of Guidelines for Dioxin Exposure Prevention in Waste Incineration Facilities”<br />
<b data-path-to-node="17,1,0" data-index-in-node="0">Scope:</b> For dioxin-exposure risk tasks classified as “Level 1.” (※)<br />
<b data-path-to-node="17,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified product (High airflow, PL3 or PS3).</p>
<p>(※) RL3 or RS3 dust masks may be used, but PAPR with higher protective performance is recommended.</p>
<h4 data-path-to-node="18"><b data-path-to-node="18" data-index-in-node="0">6. Handling Refractory Ceramic Fibers (RCF)</b></h4>
<p><b data-path-to-node="19,0,0" data-index-in-node="0">Regulation:</b> “Ordinance on Prevention of Hazards due to Specified Chemical Substances”<br />
<b data-path-to-node="19,1,0" data-index-in-node="0">Scope:</b> Insulation or fireproofing work involving the application of RCF to furnaces or boilers; or repair, dismantling, and demolition of such furnaces/boilers.<br />
<b data-path-to-node="19,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified product (PL3 or PS3).</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong>PAPR Standards</strong></th>
<td width="64">Beyond JIS standards, Powered Air-Purifying Respirators must adhere to standards defined under the Industrial Safety and Health Act. These comprehensive standards ensure that products are manufactured under strict safety requirements.</td>
</tr>
</tbody>
</table>
<p>The following table is excerpted from the ‘Standards for Powered Air-Purifying Respirators’</p>
<h3>Types of Powered Air-Purifying Respirators</h3>
<table>
<tbody>
<tr>
<th colspan="2"><strong>Powered Air-Purifying Particulate Respirator (P-PAPR)</strong></th>
</tr>
<tr>
<th rowspan="2"><strong>Powered Air-Purifying Gas Respirator (G-PAPR)</strong></th>
<td>Type with dust protection function</td>
</tr>
<tr>
<td>Type without dust protection function</td>
</tr>
</tbody>
</table>
<p><strong>■ Classification by Shape</strong></p>
<table>
<tbody>
<tr>
<th rowspan="2"><strong>Tight-fitting Facepiece</strong><br />
<span class="sub-item">・Full-face</span><br />
<span class="sub-item">・Half-face</span></th>
<td>Isolation type (with hose)</td>
</tr>
<tr>
<td>Direct connection type</td>
</tr>
<tr>
<th rowspan="2"><strong>Loose-fitting Facepiece</strong><br />
<span class="sub-item">・Hood</span><br />
<span class="sub-item">・Face shield</span></th>
<td>Isolation type (with hose)</td>
</tr>
<tr>
<td>Direct connection type</td>
</tr>
</tbody>
</table>
<p><strong>■ Classification by Performance</strong></p>
<table>
<thead>
<tr>
<th><strong>Airflow Performance Classification</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>Standard airflow type</td>
</tr>
<tr>
<td>High airflow type</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th><strong>Leakage Rate Performance Classification (P-PAPR)</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>Class B</td>
</tr>
<tr>
<td>Class A</td>
</tr>
<tr>
<td>Class S</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th colspan="2"><strong>Filter Material Performance Classification<br />
(P-PAPR and G-PAPR with dust function)</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td width="50%">PS1</td>
<td width="50%">PL1</td>
</tr>
<tr>
<td>PS2</td>
<td>PL2</td>
</tr>
<tr>
<td>PS3</td>
<td>PL3</td>
</tr>
</tbody>
</table>
<h3>Performance Testing for Powered Air-Purifying Respirators</h3>
<h4><strong>■ Particle Collection Efficiency Test</strong></h4>
<p>(Applies only to P-PAPR and G-PAPR with dust protection)</p>
<table>
<tbody>
<tr>
<th class="header-bg col-label" rowspan="3"><strong>Test Particle</strong></th>
<th class="header-bg col-sub"><strong>Type</strong></th>
<td class="align-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="align-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="header-bg"><strong>Particle Size</strong></th>
<td colspan="2">0.06μm ~ 0.1μm</td>
<td colspan="2">0.15μm ~ 0.25μm</td>
</tr>
<tr>
<th class="header-bg"><strong>Concentration</strong></th>
<td colspan="2">50mg/m³ or less</td>
<td colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="header-bg" rowspan="2"><strong>Test Flow Rate</strong></th>
<th class="header-bg"><strong>Standard Flow</strong></th>
<td colspan="4">104 L/min</td>
</tr>
<tr>
<th class="header-bg"><strong>High Flow</strong></th>
<td colspan="4">138 L/min</td>
</tr>
<tr>
<th class="header-bg align-left" colspan="2" rowspan="4"><strong>Collection Efficiency<br />
(Continuous measurement; must meet values in the right column)</strong></th>
<td colspan="2">For NaCl, loaded up to 200mg</td>
<td colspan="2">For DOP, loaded up to 400mg</td>
</tr>
<tr>
<td class="col-val">PS1</td>
<td class="col-res">95.0% or more</td>
<td class="col-val">PL1</td>
<td class="col-res">95.0% or more</td>
</tr>
<tr>
<td>PS2</td>
<td>99.0% or more</td>
<td>PL2</td>
<td>99.0% or more</td>
</tr>
<tr>
<td>PS3</td>
<td>99.97% or more</td>
<td>PL3</td>
<td>99.97% or more</td>
</tr>
</tbody>
</table>
<h4><strong>■ Canister Testing</strong></h4>
<p>(Applies only to G-PAPR)</p>
<table>
<tbody>
<tr>
<th><strong>Airtightness</strong></th>
<td class="align-left" colspan="4">No air leakage at 1470 Pa pressure</td>
</tr>
<tr>
<th rowspan="5"><strong>Decontamination Capacity<br />
(Time until breakthrough at specified concentration must be ≥ the right column)</strong></th>
<th><strong>Type</strong></th>
<th><strong>Test Gas</strong></th>
<th><strong>Breakthrough Concentration</strong></th>
<th><strong>Duration</strong></th>
</tr>
<tr>
<td>Halogen gas</td>
<td>Chlorine (0.02%)</td>
<td>1 ppm</td>
<td>40 mins or more</td>
</tr>
<tr>
<td>Organic gas</td>
<td>Cyclohexane (0.03%)</td>
<td>5 ppm</td>
<td>50 mins or more</td>
</tr>
<tr>
<td>Ammonia</td>
<td>Ammonia (0.1%)</td>
<td>50 ppm</td>
<td>40 mins or more</td>
</tr>
<tr>
<td>SO₂ gas</td>
<td>Sulfur dioxide (0.03%)</td>
<td>5 ppm</td>
<td>35 mins or more</td>
</tr>
<tr>
<th><strong>Leakage Concentration</strong></th>
<td class="align-left" colspan="4">At maximum flow rate, time to reach breakthrough must be ≥ 3 minutes.</td>
</tr>
</tbody>
</table>
<h4><strong>■ Inward Leakage Rate Test</strong></h4>
<table>
<colgroup>
<col />
<col />
<col />
<col /></colgroup>
<tbody>
<tr>
<th rowspan="3"><strong>Test Particle</strong></th>
<th><strong>Type</strong></th>
<td colspan="4">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<th><strong>Particle Size</strong></th>
<td colspan="4">0.06μm ~ 0.2μm</td>
</tr>
<tr>
<th><strong>Concentration</strong></th>
<td colspan="4">18mg/m³ or less</td>
</tr>
<tr>
<th rowspan="4"><strong>Simulated Breathing</strong></th>
<th><strong>Type</strong></th>
<td colspan="2">Standard Flow</td>
<td colspan="2">High Flow</td>
</tr>
<tr>
<th><strong>Waveform</strong></th>
<td colspan="4">Sine wave</td>
</tr>
<tr>
<th><strong>Ventilation Volume</strong></th>
<td colspan="2">1.5 ± 0.075 L/stroke</td>
<td colspan="2">1.6 ± 0.08 L/stroke</td>
</tr>
<tr>
<th><strong>Frequency</strong></th>
<td colspan="2">20 times/min</td>
<td colspan="2">25 times/min</td>
</tr>
<tr>
<th colspan="2" rowspan="4"><strong>Leakage Rate<br />
(2-minute continuous measurement; max value must meet the right column)</strong></th>
<td rowspan="3">P-PAPR</td>
<td>Class B</td>
<td colspan="2">5.0% or less</td>
</tr>
<tr>
<td>Class A</td>
<td colspan="2">1.0% or less</td>
</tr>
<tr>
<td>Class S</td>
<td colspan="2">0.1% or less</td>
</tr>
<tr>
<td>G-PAPR</td>
<td colspan="3">0.1% or less</td>
</tr>
<tr>
<th colspan="2" rowspan="4"><strong>Headform Movement<br />
(Calculate leakage rate for each item)</strong></th>
<th colspan="3"><strong>Position and Range</strong></th>
<th><strong>Frequency</strong></th>
</tr>
<tr>
<td rowspan="2">Head</td>
<td colspan="2">Front/Back 30 degrees</td>
<td>17 times/min</td>
</tr>
<tr>
<td colspan="2">Left/Right rotation 50 degrees</td>
<td>11 times/min</td>
</tr>
<tr>
<td>Arms</td>
<td colspan="2">Raising 10 ~ 130 degrees</td>
<td>7 times/min</td>
</tr>
</tbody>
</table>
<h4><strong>■ Other Tests</strong></h4>
<table>
<tbody>
<tr>
<th><strong>Internal Pressure<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">Under simulated breathing identical to the leakage test:<br />
0 Pa &lt; Internal Mask Pressure &lt; 400 Pa</td>
</tr>
<tr>
<th rowspan="2"><strong>Minimum Required Flow<br />
(Loose-fit only)</strong></th>
<td class="align-center">Standard Flow</td>
<td class="align-center">104 L/min or more</td>
</tr>
<tr>
<td class="align-center">High Flow</td>
<td class="align-center">138 L/min or more</td>
</tr>
<tr>
<th><strong>Inhalation Resistance<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">160 Pa or less<br />
(40 L/min flow rate, fan OFF)</td>
</tr>
<tr>
<th><strong>Exhalation Resistance<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">80 Pa or less<br />
(40 L/min flow rate, fan OFF)</td>
</tr>
<tr>
<th><strong>Exhalation Valve Airtightness<br />
(Tight-fitting only)</strong></th>
<td class="content-cell" colspan="2">・Internal pressure must drop immediately when air is sucked.<br />
・Time for pressure to return to normal must be ≥ 15 seconds.</td>
</tr>
<tr>
<th><strong>CO2 Concentration Increase<br />
(Tight-fitting only)</strong></th>
<td class="content-cell" colspan="2">With fan OFF, headform breathes CO2 air. Difference between wearing and not wearing mask must be &lt; 2.0%.</td>
</tr>
<tr>
<th><strong>Noise Level</strong></th>
<td class="align-center" colspan="2">Noise at the headform ear area must be below 80 dB (both sides).</td>
</tr>
<tr>
<th rowspan="4"><strong>Flow Rate<br />
(G-PAPR only)</strong></th>
<td>Max set average flow</td>
<td class="content-cell">Average must be ≤ the decontamination test flow rate.</td>
</tr>
<tr>
<td>Maximum flow</td>
<td class="content-cell">Maximum must be ≤ the flow rate set by the manufacturer.</td>
</tr>
<tr>
<th><strong>Tight-fitting type</strong></th>
<th><strong>Loose-fitting type</strong></th>
</tr>
<tr>
<td class="content-cell">Measure resistance with fan OFF/ON at 20~170 L/min to calculate flow per minute.</td>
<td class="content-cell">With fan ON, draw air for 5 mins to maintain normal pressure in chamber, then measure flow.</td>
</tr>
</tbody>
</table>
<h2>PAPR USE IS ENCOURAGED IN THE 10TH COMPREHENSIVE DUST HAZARD COUNTERMEASURES</h2>
<p><strong>To reduce pneumoconiosis, dust prevention measures must be strengthened.</strong></p>
<p>The “10th Comprehensive Countermeasures for Preventing Dust Hazards” demands the correct use of effective respiratory protection against dust exposure across all industries. PAPR is highlighted as a “more effective preventive measure for health impairment,” and its adoption is highly encouraged.<br />
The use of PAPR is more effective in preventing health impairment compared to standard dust masks due to its higher protection factor and reduced physical strain on the wearer.<br />
(Partial excerpt from the 10th Comprehensive Countermeasures)</p>
<p>Furthermore, due to high performance, PAPR is mandatory for specific tasks, but its use is also recommended for tasks outside the mandatory categories.<br />
While PAPR is mandatory for specific operations under the Dust Rules, its high performance makes it desirable for other tasks; thus, guidance and inspections encourage businesses to adopt PAPR for their workers.<br />
(Partial excerpt from the 10th Comprehensive Countermeasures)</p>
<h2>KOKEN BL SERIES BREATH-RESPONSIVE PAPR</h2>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Achieving “High Safety” and “Comfortable Fit” as expected</b></p>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">THE EVOLUTION OF THE BL SERIES</b></p>
<p data-path-to-node="6">The BL Series continues to evolve into the PAPR model that helps perfect safety and health management in every field, aligning with occupational health trends and market expansion.</p>
<p data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">CORE DEVELOPMENT FOCUS</b></p>
<ul>
<li data-path-to-node="8,0,0"><b data-path-to-node="8,0,0" data-index-in-node="0">“Safety”:</b> Improving the protection capability as a respirator.</li>
<li data-path-to-node="8,1,0"><b data-path-to-node="8,1,0" data-index-in-node="0">“Flow Technology”:</b> Minimizing waste and improving efficiency.</li>
<li data-path-to-node="8,2,0"><b data-path-to-node="8,2,0" data-index-in-node="0">“Lightweight Design”:</b> Reducing the burden on the worker.</li>
</ul>
<h2>KOKEN FLOW TECHNOLOGY: New BSFS air flow highly synchronized with breathing</h2>
<h3>THE MECHANISM OF THE BSFS (BREATH SYNCHRONIZED) SYSTEM</h3>
<p data-path-to-node="5">The BL Series is equipped with the Breath Synchronized-Air Flow System (new BSFS), which delivers airflow that follows the breathing rhythm more closely than ever, becoming a “Highly Synchronized” model.<br />
BSFS ELIMINATES THE FEELING OF BREATHLESSNESS/STUFFINESS<br />
<img loading="lazy" decoding="async" class="size-medium wp-image-191639 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-300x177.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-300x177.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4.jpg 464w" alt="" width="300" height="177" /></p>
<p><b data-path-to-node="2" data-index-in-node="0">THE BSFS MECHANISM HAS EVOLVED INTO “HIGH SYNCHRONIZATION”</b></p>
<p data-path-to-node="3">Using a fan equipped with a breath detection sensor, the device supplies “the necessary and sufficient amount of air” corresponding to the user’s inhalation. Responsiveness to breathing has been improved, and the accuracy of synchronization with the respiratory rhythm has significantly increased.<br />
<img loading="lazy" decoding="async" class="size-medium wp-image-191638 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-300x286.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-300x286.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-768x733.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1.jpg 1024w" alt="" width="300" height="286" /></p>
<h3>COMFORT UP</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">SOLVING MASK DISCOMFORT WITH FLOW THAT FOLLOWS EVERY BREATH</b></p>
<ul>
<li data-path-to-node="4,0,0">Reduces the physical workload for laborers.</li>
<li data-path-to-node="4,1,0">Solves breathing difficulties and stuffiness in high-temperature workplaces.</li>
</ul>
<h3>SAFETY UP</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">PREVENTING INWARD LEAKAGE THROUGH HIGH PROTECTION AND CONSTANT POSITIVE PRESSURE</b></p>
<p data-path-to-node="4,0,0">Breath Synchronization: Protection is guaranteed by the blower linked to breathing.</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class=" wp-image-191633 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-300x227.jpg" sizes="auto, (max-width: 441px) 100vw, 441px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-300x227.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-768x581.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6.jpg 1024w" alt="" width="441" height="334" /></td>
<td width="64"><img loading="lazy" decoding="async" class=" wp-image-191636 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-300x218.png" sizes="auto, (max-width: 508px) 100vw, 508px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-300x218.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-1024x745.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-768x559.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185.png 1407w" alt="" width="508" height="369" /></td>
</tr>
<tr>
<td height="19">
<p data-path-to-node="3,0,0"><b data-path-to-node="3,0,0" data-index-in-node="0">DURING INHALATION:</b> Air inside the mask is normally sucked away, but supplemental airflow prevents negative pressure. (If a gap exists, air blows outward ※1)</p>
<p data-path-to-node="3,0,0">※1: Airflow varies based on facepiece fit.</p>
</td>
<td>
<p data-path-to-node="3,1,0"><b data-path-to-node="3,1,0" data-index-in-node="0">DURING EXHALATION:</b> Since pressure doesn’t drop, airflow is reduced. This conserves the “filter” and “battery.”</p>
<p data-path-to-node="3,1,0">※2: Flow doesn’t stop completely (maintains a small amount for safety).</p>
</td>
</tr>
</tbody>
</table>
<p><b data-path-to-node="2" data-index-in-node="0">PAPR AVOIDS HIGH LEAKAGE RISKS FROM DUST BUILDUP IN LOOSE MASKS</b></p>
<p data-path-to-node="3">FOR CONVENTIONAL DUST MASKS:</p>
<p data-path-to-node="4">As dust builds on the filter, inhalation resistance increases, raising the risk of inward leakage. As dust accumulates, even if the gap remains the same, the leakage rate can double. (See diagram below)</p>
<p><img loading="lazy" decoding="async" class=" wp-image-191632 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-300x195.jpg" sizes="auto, (max-width: 409px) 100vw, 409px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-300x195.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-768x500.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-180x118.jpg 180w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8.jpg 1024w" alt="" width="409" height="266" /></p>
<p><b data-path-to-node="7" data-index-in-node="0">Leakage Measurement Method:</b> A 2.5% gap is created intentionally; NaCl concentration is measured inside/outside the mask with a digital meter.</p>
<h3>ECONOMY UP (ECO)</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">ELIMINATING WASTE THROUGH AN ECO FLOW MECHANISM</b></p>
<p data-path-to-node="4,0,0">Limits “wasteful dust buildup” and reduces filter usage: Minimizes air loss to reduce clogging.<br />
Limits battery usage: Extends runtime by reducing power consumption during low-respiration phases.</p>
<p><b data-path-to-node="2" data-index-in-node="0">BATTERY RUNTIME COMPARISON: NEW VS OLD BSFS</b></p>
<p data-path-to-node="3"><img loading="lazy" decoding="async" class=" wp-image-191631 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/1-300x126.png" sizes="auto, (max-width: 445px) 100vw, 445px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/1-300x126.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-1024x429.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-768x322.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/1.png 1536w" alt="" width="445" height="187" /></p>
<p data-path-to-node="3"><strong>ECO FLOW CREATED BY HIGH SYNCHRONIZATION</strong></p>
<p data-path-to-node="3"><img loading="lazy" decoding="async" class=" wp-image-191630 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/2-300x175.png" sizes="auto, (max-width: 456px) 100vw, 456px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/2-300x175.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-1024x599.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-768x449.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/2.png 1536w" alt="" width="456" height="266" />Image of BSFS flow following actual respiratory waveforms with high precision.</p>
<h2 data-path-to-node="3">KOKEN LIGHTWEIGHT DESIGN: Reducing burden for long shifts</h2>
<p>The “BL Series” optimizes compact sizing and weight equivalent to conventional dust masks. It is highly rated in tunnel construction, asbestos handling, and arc welding.</p>
<p><b data-path-to-node="4" data-index-in-node="0">SEPARATE TYPE</b> Because a direct-mounted battery adds weight to the neck, the separate design reduces perceived weight. This ultra-lightweight design minimizes mask body thickness.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56541" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-122956.png" alt="" width="348" height="302" /></p>
<p><b data-path-to-node="5" data-index-in-node="0">BUILT-IN TYPE</b> Thanks to “High Synchro” BSFS reducing power draw, battery size has been shrunk. This results in a lightweight built-in battery design with minimal burden.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56542" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123026.png" alt="" width="212" height="269" /></p>
<h2>KOKEN SAFETY DESIGN: Internal pressure monitoring to maintain positive pressure</h2>
<p data-path-to-node="3">(Common for BL-321/BL-351/BL-351X/BL-711/BL-700/BL-200/BL-100 series)</p>
<p data-path-to-node="4">Modern worksites require PAPRs that “constantly monitor internal pressure and provide alerts.”<br />
PAPR is most protective under positive pressure; therefore, the moment positive pressure cannot be maintained is the filter replacement time. “Internal monitoring” notifies the user when pressure drops due to weak flow.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56543" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123245.png" alt="" width="243" height="253" /></p>
<p data-path-to-node="7,0,0">■ Positive pressure inside the mask can be maintained through timely/appropriate filter replacement.<br />
■ Clarifies the standard for filter replacement – which is otherwise often vague or based on subjective estimation.<br />
■ Full airflow can be restored through proper battery charging.</p>
<p><b data-path-to-node="2" data-index-in-node="0">NOTIFICATION VIA AIRFLOW</b></p>
<p data-path-to-node="3">(For BL-321 / BL-351 / BL-351X / BL-711 series)</p>
<ul>
<li data-path-to-node="4,0,0">Pressure drop warning via “Continuous Airflow”: ➔ Replace the filter.</li>
<li data-path-to-node="4,1,0">Low battery warning via “Rhythmic Airflow”: ➔ Replace with a charged battery.</li>
</ul>
<p><b data-path-to-node="6" data-index-in-node="0">LED NOTIFICATION</b></p>
<p data-path-to-node="7">(For BL-700 / BL-200 / BL-100 series)</p>
<ul>
<li data-path-to-node="8,0,0">Pressure drop warning via “Flashing LED”: ➔ Replace the filter.</li>
<li data-path-to-node="8,1,0">Low battery warning via “Steady LED”: ➔ Replace with a charged battery.</li>
</ul>
<p><img loading="lazy" decoding="async" class=" wp-image-191629 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/3-300x65.png" sizes="auto, (max-width: 471px) 100vw, 471px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/3-300x65.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-1024x221.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-768x166.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/3.png 1536w" alt="" width="471" height="102" /></p>
<h2>POWERED AIR-PURIFYING PARTICULATE RESPIRATOR (P-PAPR)</h2>
<p>[FULL FACEPIECE TYPE]</p>
<h3>BL-711 SERIES</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Full-face PAPR model with high protective performance, also effective for eye protection</b></p>
<p data-path-to-node="4,0,0"><b data-path-to-node="4,0,0" data-index-in-node="0">Classification:</b> <b data-path-to-node="4,0,0" data-index-in-node="11">HIGH AIRFLOW TYPE</b></p>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Key Features:</b></p>
<ul>
<li data-path-to-node="6,0,0">High Synchro</li>
<li data-path-to-node="6,1,0">Silicone material</li>
<li data-path-to-node="6,2,0">HAWC Lip</li>
<li data-path-to-node="6,3,0">Speaker</li>
<li data-path-to-node="6,4,0">Special Surface Hardening</li>
</ul>
<p data-path-to-node="1,0,0">■ Built-in battery type.<br />
■ Full-face eyepiece with a wide field of vision. Special coating improves scratch resistance.<br />
■ Low battery warning via &#8220;Alert airflow&#8221; function while wearing.<br />
■ &#8220;Silicone Mask Body&#8221; provides superior durability and high cleaning efficiency.<br />
■ Integrated &#8220;Speaker&#8221; for clear conversation.<br />
■ Designed shape for easy taping.</p>
<p><b data-path-to-node="1" data-index-in-node="0">SHARED FACEPIECE BODY</b></p>
<p data-path-to-node="2">Can be used by changing the filter according to the task purpose.</p>
<ul>
<li data-path-to-node="3,0,0">Install BRD-82 Filter: Becomes BL-711H.</li>
<li data-path-to-node="3,1,0">Install BRD-82U Filter: Becomes BL-711U.</li>
<li data-path-to-node="3,2,0">Install gas canister: Can be used as a G-PAPR.</li>
</ul>
<h3>Sakai Model BL-711H-03</h3>
<p>Includes battery &amp; charger. Pattern Test Cert TP81<br />
<img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56546" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_131338-removebg-preview.png" alt="" width="374" height="362" /></p>
<ul>
<li data-path-to-node="4,0,0">PL3 efficiency</li>
<li data-path-to-node="4,1,0">Class S leakage</li>
<li data-path-to-node="4,2,0">Assigned Protection Factor: 1000</li>
<li data-path-to-node="4,3,0">Asbestos removal</li>
<li data-path-to-node="4,4,0">Indium handling</li>
<li data-path-to-node="4,5,0">RCF handling</li>
<li data-path-to-node="4,6,0">Dioxin (Level 1)</li>
</ul>
<p data-path-to-node="5"><strong>Replacement Filter:</strong> Alpha Ring Filter BRD-82</p>
<p data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">Options</b></p>
<ul>
<li data-path-to-node="8,0,0"><b data-path-to-node="8,0,0" data-index-in-node="0">Glasses Clip Type A: </b>Clip for attaching regular prescription glasses.</li>
<li data-path-to-node="8,0,0"><b data-path-to-node="8,1,0" data-index-in-node="0">Eyepiece Protector for H-VII, Type A for H-VII: </b>To protect the visor surface.</li>
</ul>
<h3><b data-path-to-node="1" data-index-in-node="0">Sakai Type</b> <b data-path-to-node="1" data-index-in-node="11">BL-711U</b></h3>
<p>Includes battery &amp; charger. Pattern Test Cert TP83<br />
<img loading="lazy" decoding="async" class=" wp-image-192548 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-2-1-227x300.jpg" alt="" width="265" height="350" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-2-1-227x300.jpg 227w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-2-1-768x1015.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-2-1.jpg 775w" sizes="auto, (max-width: 265px) 100vw, 265px" /></p>
<ul>
<li data-path-to-node="2,0,0">PL3 efficiency</li>
<li data-path-to-node="2,1,0">Class S leakage</li>
<li data-path-to-node="2,2,0">Assigned Protection Factor: 1000</li>
<li data-path-to-node="2,3,0">Nanomaterial handling</li>
</ul>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Replacement Filter: </b>Alpha Ring Filter BRD-82U</p>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Options</b></p>
<ul>
<li data-path-to-node="6,0,0"><b data-path-to-node="6,0,0" data-index-in-node="0">Glasses Clip Type A: </b>Clip for attaching regular prescription glasses.</li>
<li data-path-to-node="6,1,0"><b data-path-to-node="6,1,0" data-index-in-node="0">Eyepiece Protector for H-VII, Type A for H-VII: </b>To protect the visor surface.</li>
</ul>
<h3>Replacement Parts</h3>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><b data-path-to-node="2,0,0" data-index-in-node="0">Speaker Cover </b>Protects the speaker unit from moisture and sweat.</td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56548" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-132201.png" alt="" width="100" height="106" /></td>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><b data-path-to-node="2,1,0" data-index-in-node="0">BL Fan Unit Cover </b>Prevents dust from entering the fan.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56549" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-132216.png" alt="" width="101" height="101" /></td>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><b data-path-to-node="2,2,0" data-index-in-node="0">Moisture Sponge Type E </b>Absorbs condensation and sweat inside the mask.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56550" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-132242.png" alt="" width="103" height="98" /></td>
</tr>
</tbody>
</table>
<h3>EASY MAINTENANCE FOR DUST ACCUMULATION</h3>
<p data-path-to-node="2,0,0">For persistent dust that cannot be removed by wiping, the unit can be cleaned by rinsing with water.</p>
<p data-path-to-node="2,0,0">(Caution) Always use the maintenance-specific sealing plugs. Do not submerge the unit in water or allow water to enter the internal facepiece. Batteries and filters are not washable. Please follow the individual product manuals.</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<th class="xl65" style="height: 14.4pt; width: 192pt;" colspan="4" width="256" height="19"><strong>BL-711 SERIES, BL-700 SERIES</strong></th>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56551" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-132647.png" alt="" width="186" height="145" /></td>
<td>
<p data-path-to-node="2,0,0"><b data-path-to-node="2,0,0" data-index-in-node="0">Mask Part:</b></p>
<p data-path-to-node="2,0,1,0,0">After removing the fan unit and speaker unit (※), the mask can be rinsed with water.<br />
(※ Speaker removal applies only to BL-711 series)</p>
</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56552" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-132703.png" alt="" width="188" height="145" /></td>
<td>
<p data-path-to-node="2,1,0"><b data-path-to-node="2,1,0" data-index-in-node="0">Fan Unit Part:</b></p>
<p data-path-to-node="2,1,1,0,0">Using sealing plugs, the unit can be cleaned with a damp cloth, etc.</p>
</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr style="height: 14.4pt;">
<th class="xl65" style="height: 14.4pt; width: 96pt;" colspan="2" width="128" height="19"><strong>BL-321, BL-351X, BL-351 SERIES</strong></th>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56553" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-132717.png" alt="" width="187" height="143" /></td>
<td>Using sealing plugs, these models can be cleaned by rinsing off external dirt with water.</td>
</tr>
</tbody>
</table>
<h3>Performance Specifications</h3>
<table class="spec-table">
<thead>
<tr>
<th rowspan="2"><strong>Product Name</strong></th>
<th colspan="3"><strong>Classification</strong></th>
<th rowspan="2"><strong>Collection Efficiency</strong></th>
<th rowspan="2"><strong>Weight (incl. battery)</strong></th>
<th rowspan="2"><strong>Facepiece Weight</strong></th>
<th rowspan="2"><strong>Battery Specs</strong></th>
<th rowspan="2"><strong>Nominal Runtime*1</strong></th>
<th rowspan="2"><strong>Actual Runtime*2</strong></th>
<th rowspan="2"><strong>Fan Lifespan</strong></th>
</tr>
<tr>
<th><strong>Fan Type</strong></th>
<th><strong>Leakage Rate</strong></th>
<th><strong>Filter Grade</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td class="product">BL-711H</td>
<td rowspan="4">High Airflow</td>
<td rowspan="4">Class S (≤0.1%)</td>
<td rowspan="4">PL3</td>
<td>99.97% or more</td>
<td colspan="2">≤753g (Avg 723g)</td>
<td class="left" rowspan="4">Li-ion Rechargeable<br />
Voltage: 7.2V<br />
Capacity: 2000mAh<br />
Charging: ~3 hours*3<br />
Cycles: ~300 times*3</td>
<td rowspan="2">Approx. 6 hours</td>
<td rowspan="2">Approx. 6.5–10 hours</td>
<td rowspan="20">Approx. 2,000 hours*3</td>
</tr>
<tr>
<td class="product">BL-711U</td>
<td>99.99% or more</td>
<td colspan="2">≤753g (Avg 720g)</td>
</tr>
<tr>
<td class="product">BL-700HA</td>
<td>99.97% or more</td>
<td rowspan="2">≤774g</td>
<td rowspan="2">Avg 591g</td>
<td rowspan="2">Approx. 7.5 hours</td>
<td rowspan="2">Approx. 8–14.5 hours</td>
</tr>
<tr>
<td class="product">BL-700U</td>
<td>99.99% or more</td>
</tr>
<tr>
<td class="product">BL-7005/AL</td>
<td rowspan="3">Standard Airflow</td>
<td rowspan="3">Class A (≤1.0%)</td>
<td>PL2</td>
<td>99.0% or more</td>
<td colspan="2">≤298g (Avg 288g)</td>
<td rowspan="5">Li-ion Rechargeable<br />
Voltage: 3.7V<br />
Capacity: 1100mAh<br />
Charging: ~3 hours*3<br />
Cycles: ~300 times*3</td>
<td>Approx. 6.7 hours</td>
<td>Approx. 4–9 hours</td>
</tr>
<tr>
<td class="product">BL-1005/AL</td>
<td rowspan="3">PL1</td>
<td>95.0% or more</td>
<td colspan="2">≤278g (Avg 271g)</td>
<td rowspan="2">Approx. 8.5 hours</td>
<td rowspan="2">Approx. 3.5–11 hours</td>
</tr>
<tr>
<td class="product">BL-1005X/AL</td>
<td>95.0% or more</td>
<td colspan="2">≤285g (Avg 278g)</td>
</tr>
<tr>
<td class="product">BL-321S</td>
<td rowspan="13">High Airflow</td>
<td>Class B (≤5.0%)</td>
<td>95.0% or more</td>
<td colspan="2">≤252g (Avg 244g)</td>
<td>Approx. 3.5 hours</td>
<td>Approx. 5–9 hours</td>
</tr>
<tr>
<td class="product">BL-321H</td>
<td>Class S (≤0.1%)</td>
<td>PL3</td>
<td>99.97% or more</td>
<td colspan="2">≤265g (Avg 257g)</td>
<td>Approx. 3 hours</td>
<td>Approx. 3–6 hours</td>
</tr>
<tr>
<td class="product">BL-351S</td>
<td>Class B (≤5.0%)</td>
<td>PL1</td>
<td>95.0% or more</td>
<td colspan="2">Avg 315g</td>
<td rowspan="11">Li-ion Rechargeable<br />
Voltage: 7.2V<br />
Capacity: 2000mAh<br />
Charging: ~3 hours*3<br />
Cycles: ~300 times*3</td>
<td>Approx. 10 hours</td>
<td>Approx. 13–22 hours</td>
</tr>
<tr>
<td class="product">BL-351H</td>
<td rowspan="3">Class S (≤0.1%)</td>
<td rowspan="3">PL3</td>
<td>99.97% or more</td>
<td colspan="2" rowspan="2">Avg 328g</td>
<td rowspan="3">Approx. 9 hours</td>
<td rowspan="3">Approx. 8–17 hours</td>
</tr>
<tr>
<td class="product">BL-351U</td>
<td>99.99% or more</td>
</tr>
<tr>
<td class="product">BL-351HX</td>
<td>99.97% or more</td>
<td colspan="2">Avg 333g</td>
</tr>
<tr>
<td class="product">BL-200S</td>
<td>Class B (≤5.0%)</td>
<td>PL1</td>
<td>95.0% or more</td>
<td>≤395g</td>
<td>Avg 219g</td>
<td>Approx. 10.5 hours</td>
<td>Approx. 12–22 hours</td>
</tr>
<tr>
<td class="product">BL-200H</td>
<td rowspan="2">Class S (≤0.1%)</td>
<td rowspan="2">PL3</td>
<td>99.97% or more</td>
<td rowspan="2">≤409g</td>
<td rowspan="2">Avg 234g</td>
<td rowspan="2">Approx. 9.5 hours</td>
<td rowspan="2">Approx. 10–18 hours</td>
</tr>
<tr>
<td class="product">BL-200U</td>
<td>99.99% or more</td>
</tr>
<tr>
<td class="product">BL-100S</td>
<td rowspan="2">Class B (≤5.0%)</td>
<td rowspan="2">PL1</td>
<td rowspan="2">95.0% or more</td>
<td rowspan="2">≤383g</td>
<td rowspan="2">Avg 206g</td>
<td rowspan="2">Approx. 10 hours</td>
<td rowspan="2">Approx. 12–22 hours</td>
</tr>
<tr>
<td class="product">BL-100SC</td>
</tr>
<tr>
<td class="product">BL-100H</td>
<td rowspan="2">Class S (≤0.1%)</td>
<td rowspan="2">PL3</td>
<td>99.97% or more</td>
<td rowspan="2">≤397g</td>
<td rowspan="2">Avg 222g</td>
<td rowspan="2">Approx. 9 hours</td>
<td rowspan="2">Approx. 10–18 hours</td>
</tr>
<tr>
<td class="product">BL-100U</td>
<td>99.99% or more</td>
</tr>
</tbody>
</table>
<div class="note">
<div>*1 Calculated duration for maintaining positive pressure inside the facepiece under standard indoor conditions.</div>
<div>*2 Observed duration for maintaining positive pressure in dusty environments, based on actual worker respiratory data during field work.</div>
<div>*3 May vary or be shorter depending on actual usage conditions.</div>
</div>
<h3>Replacement Filters and Optional Accessories</h3>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56559" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_133302-removebg-preview.png" sizes="auto, (max-width: 263px) 100vw, 263px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_133302-removebg-preview.png 263w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_133302-removebg-preview-180x118.png 180w" alt="" width="263" height="171" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56560" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_133247-removebg-preview.png" alt="" width="261" height="166" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56558" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_133314-removebg-preview.png" alt="" width="249" height="169" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56554" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-133324.png" alt="" width="228" height="169" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56555" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-133334.png" alt="" width="231" height="166" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56556" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-133347.png" alt="" width="299" height="119" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56557" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-133356.png" alt="" width="261" height="116" /></td>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><strong>Alpha Ring Filter BRD-8U</strong><br />
Screw-on / Twist-lock</td>
<td><strong>Alpha Ring Filter BRD-82</strong><br />
Screw-on / Twist-lock</td>
<td><strong>Alpha Ring Filter BRD-82U</strong><br />
Screw-on / Twist-lock</td>
<td><strong>Alpha Ring Filter BLA-62</strong></td>
<td><strong>Alpha Ring Filter BRD-7</strong></td>
<td><strong>Mighty Micron Filter For BL-7005</strong></td>
<td><strong>Mighty Micron Filter For BL-1005</strong></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td class="xl65" style="height: 14.4pt; width: 96pt;" colspan="2" width="128" height="19">Optional: For Ozone / Organic odor removal (5 pcs/pack)</td>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><img loading="lazy" decoding="async" class="aligncenter wp-image-56561" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-134109.png" sizes="auto, (max-width: 366px) 100vw, 366px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-134109.png 497w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-134109-300x112.png 300w" alt="" width="366" height="136" /></td>
<td><img loading="lazy" decoding="async" class=" wp-image-191670 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-768x323-1-300x139.png" sizes="auto, (max-width: 319px) 100vw, 319px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-768x323-1-300x139.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-768x323-1-1024x474.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-768x323-1-768x355.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-768x323-1.png 1500w" alt="" width="319" height="148" /></td>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19">KBC Filter For BL-7005</td>
<td>KBC Filter For BL-1005</td>
</tr>
</tbody>
</table>
<p data-path-to-node="1,0,0">When performing tasks such as welding or grinding that generate sparks or spatter, it is mandatory to install the dedicated inhalation port cover (sold separately) on the filter (except for the BL-7005 and BL-1005 series). Note that the BL-700HA/U, BL-200H/U, and BL-100H/U series are not designed for use in environments with sparks or spatter.</p>
<h3 data-path-to-node="0">Key Features:</h3>
<ul>
<li data-path-to-node="1"><b data-path-to-node="1" data-index-in-node="0">High Synchro: </b>Next-generation model improves airflow efficiency and tracks user breathing rhythm more accurately.</li>
<li data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Fit Checker: </b>Easily perform a fit test by simply pulling the lever.</li>
<li data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Under Chin: </b>Unique curved design enhances the airtight seal at the face contact area.</li>
<li data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">Micron: </b>High-performance electrostatic filter. This mask utilizes Micron filter technology.</li>
<li data-path-to-node="9"><b data-path-to-node="9" data-index-in-node="0">Speaker: </b>Integrated small communication speaker ensures clear dialogue while wearing the mask.</li>
<li data-path-to-node="11"><b data-path-to-node="11" data-index-in-node="0">Special Hard Coating: </b>Improved scratch resistance compared to standard surface hardening methods.</li>
<li data-path-to-node="12,0,0"><b data-path-to-node="14" data-index-in-node="0">Silicone: </b>The facepiece uses high-grade silicone material for a soft, skin-friendly fit.</li>
<li data-path-to-node="16"><b data-path-to-node="16" data-index-in-node="0">Speaking Diaphragm: </b>Facilitates clear communication and instruction without mask removal.</li>
<li data-path-to-node="18"><b data-path-to-node="18" data-index-in-node="0">Internal Pressure Monitoring: </b>Flashing light alerts the user when positive pressure is lost inside the facepiece.</li>
<li data-path-to-node="20"><b data-path-to-node="20" data-index-in-node="0">HAWC Lip: </b>Full-face models use the HAWC Lip structure for a high-seal &#8220;suction cup effect.&#8221;</li>
<li data-path-to-node="22"><b data-path-to-node="22" data-index-in-node="0">Hardened Eyepiece: </b>The visor surface is treated with a hardening process to resist scratches.</li>
</ul>The post <a href="https://koueitrading.com/global/product/koken-bl-711-series-p-papr/">Koken BL-711 Series P-PAPR</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken BL-700 Series P-PAPR</title>
		<link>https://koueitrading.com/global/product/koken-bl-700-series-p-papr/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 12 Mar 2020 03:41:44 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192534</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: BL-700 Series P-PAPR: Powered Air-Purifying Particulate Respirator PARTICULATE PAPR and GAS PAPR PAPR: Powered Air-Purifying Respirator. P-PAPR: Particulate PAPR (Used for dust/particles). G-PAPR: Gas PAPR (Used for toxic gases/vapors). Within the PAPR range, there are “Powered Air-Purifying Particulate Respirators (P-PAPR)” for dust hazards and “Powered Air-Purifying Gas Respirators (G-PAPR)” for toxic [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-bl-700-series-p-papr/">Koken BL-700 Series P-PAPR</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: BL-700 Series</p>
<p>P-PAPR: Powered Air-Purifying Particulate Respirator</p>
<h2>PARTICULATE PAPR and GAS PAPR</h2>
<ul>
<li data-path-to-node="14,0,0">PAPR: Powered Air-Purifying Respirator.</li>
<li data-path-to-node="14,1,0">P-PAPR: Particulate PAPR (Used for dust/particles).</li>
<li data-path-to-node="14,2,0">G-PAPR: Gas PAPR (Used for toxic gases/vapors).</li>
</ul>
<p data-path-to-node="3">Within the PAPR range, there are “Powered Air-Purifying Particulate Respirators (P-PAPR)” for dust hazards and “Powered Air-Purifying Gas Respirators (G-PAPR)” for toxic gas hazards. It is essential to understand the properties, type, and concentration of the hazardous substances before selecting the appropriate mask.</p>
<p data-path-to-node="3">To prevent inhalation of DUST -&gt; Use a Powered Air-Purifying Particulate Respirator (P-PAPR)<br />
To prevent inhalation of TOXIC GAS -&gt; Use a Powered Air-Purifying Gas Respirator (G-PAPR)<br />
To prevent inhalation of MIXED DUST &amp; TOXIC GAS -&gt; Use a Powered Air-Purifying Gas Respirator (G-PAPR) with dust protection function</p>
<h3>Environments where PAPR CANNOT be used</h3>
<p data-path-to-node="9">PAPR must not be used if any of the following conditions apply. Please use respiratory protective equipment suitable for the environment, such as a supplied-air respirator or a self-contained breathing apparatus (SCBA).</p>
<ul>
<li data-path-to-node="10,0,0">Oxygen-deficient environments or those at risk of oxygen deficiency (Oxygen concentration below 18%).</li>
<li data-path-to-node="10,1,0">Cases where the type or concentration of the toxic gas is unknown.</li>
<li data-path-to-node="10,2,0">IDLH environments (Atmospheres Immediately Dangerous to Life or Health).</li>
<li data-path-to-node="10,2,0">Cases where the toxic gas concentration exceeds the permissible limit for the PAPR. ※</li>
<li data-path-to-node="10,3,0">Cases where no filter (canister) is available to remove the specific toxic gas in the environment.</li>
<li data-path-to-node="10,4,0">Cases where a mixture of gases with different properties exists.</li>
<li data-path-to-node="10,5,0">Cases where the environment deviates significantly from normal temperature, humidity, and atmospheric pressure.</li>
</ul>
<p data-path-to-node="11">(※ According to standards based on the Industrial Safety and Health Act, the application range of G-PAPR is 2% (3% for Ammonia))</p>
<h3>SELECTING THE APPROPRIATE PAPR BASED ON HAZARD CONCENTRATION</h3>
<p data-path-to-node="3">Determine the Required Protection Factor, then select a PAPR model with an Assigned Protection Factor higher than that value.</p>
<p data-path-to-node="4,0">Formula: How to calculate the Required Protection Factor<br />
<strong>Required Protection Factor = Ambient concentration of identified hazard / Permissible exposure limit of the hazard</strong></p>
<p>Assigned Protection Factor of P-PAPR</p>
<table>
<thead>
<tr>
<th colspan="2"><strong>Classification</strong></th>
<th colspan="4"><strong>Facepiece Type</strong></th>
</tr>
<tr>
<th><strong>Leakage Rate</strong></th>
<th><strong>Filter Efficiency</strong></th>
<th><strong>Half-face</strong></th>
<th><strong>Full-face</strong></th>
<th><strong>Hood Type</strong></th>
<th><strong>Face shield</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td rowspan="3">Class S</td>
<td>PL3/PS3</td>
<td>50/300</td>
<td>1000</td>
<td>25/1000</td>
<td>25/300</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>—</td>
<td>—</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td rowspan="3">Class A</td>
<td>PL3/PS3</td>
<td>—</td>
<td>—</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>33</td>
<td>90</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>14</td>
<td>19</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td rowspan="3">Class B</td>
<td>PL3/PS3</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>14</td>
<td>19</td>
<td>11</td>
<td>11</td>
</tr>
</tbody>
</table>
<p>Assigned Protection Factor of G-PAPR</p>
<table>
<thead>
<tr>
<th class="header-main" colspan="4"><strong>Facepiece Type</strong></th>
</tr>
<tr>
<th><strong>Half-face</strong></th>
<th><strong>Full-face</strong></th>
<th><strong>Hood Type</strong></th>
<th><strong>Face shield</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>50/300</td>
<td>1000</td>
<td>25/1000</td>
<td>25/300</td>
</tr>
</tbody>
</table>
<p>For “G-PAPR with dust protection function,” please refer to the Assigned Protection Factor of P-PAPR (Class S leakage rate) mentioned above for dust (and similar particulates).</p>
<h2>TASKS WHERE PAPR USE IS MANDATORY BY REGULATION OR DIRECTIVE</h2>
<p><strong>For tasks where PAPR use is mandatory by regulation or directive, please use a PAPR with the designated performance classification.</strong></p>
<h4><strong>1. Tunnel Construction Work</strong></h4>
<p><strong>Regulation:</strong> “Ordinance on Prevention of Pneumoconiosis”<br />
<strong>Scope:</strong> In tunnel construction, at locations involving “mechanical/powered excavation,” “mechanical loading or unloading of ore/rock,” and “shotcreting.”</p>
<p><strong>PAPR Requirements:</strong></p>
<ul>
<li>National test certified product (High airflow type).</li>
<li>Tight-fitting facepiece type where the battery can be removed for use during blasting operations.</li>
</ul>
<h4><strong>2. Asbestos Removal Work</strong></h4>
<p><strong>Regulation:</strong> “Ordinance on Prevention of Health Impairment due to Asbestos”<br />
<strong>Scope</strong>: In asbestos removal tasks, specifically those requiring “Class 1 Asbestos Removal Masks.”<br />
<b data-path-to-node="11,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified tight-fitting or hood types (High airflow, Class S, PL3 or PS3).</p>
<h4 data-path-to-node="12"><b data-path-to-node="12" data-index-in-node="0">3. Handling Nanomaterials</b></h4>
<p data-path-to-node="13,0,0"><b data-path-to-node="13,0,0" data-index-in-node="0">Directive:</b> “Regarding Preventive Measures for Exposure to Nanomaterials”<br />
<b data-path-to-node="13,1,0" data-index-in-node="0">Scope:</b> Manufacturing and handling of nanomaterials. (※)<br />
<b data-path-to-node="13,2,0" data-index-in-node="0">PAPR Requirements:</b></p>
<ul>
<li data-path-to-node="13,2,0">National test certified product (High airflow, PL3 or PS3).</li>
<li data-path-to-node="13,2,1,0,0">Shape limitations based on the projected exposure levels of workers.</li>
</ul>
<p data-path-to-node="13,2,1,1,0">(※) Depending on the work environment, respiratory protective equipment other than PAPR may be used.</p>
<h4 data-path-to-node="14"><b data-path-to-node="14" data-index-in-node="0">4. Handling Indium</b></h4>
<p data-path-to-node="15,0,0"><b data-path-to-node="15,0,0" data-index-in-node="0">Directive:</b> “Regarding Thorough Health Hazard Prevention Measures for Indium/Tin Oxide Handling”<br />
<b data-path-to-node="15,1,0" data-index-in-node="0">Scope:</b> Handling of Indium, Tin Oxide, etc. (※)<br />
<b data-path-to-node="15,2,0" data-index-in-node="0">PAPR Requirements:</b></p>
<ul>
<li data-path-to-node="15,2,0">National test certified product (High airflow, PL3 or PS3).</li>
<li data-path-to-node="15,2,1,0,0">Limitations on shape and leakage rate based on working environment measurement results.</li>
</ul>
<p data-path-to-node="15,2,1,1,0">(※) Depending on environmental results, respiratory protective equipment other than PAPR may be used.</p>
<h4 data-path-to-node="16"><b data-path-to-node="16" data-index-in-node="0">5. Handling Dioxins</b></h4>
<p><b data-path-to-node="17,0,0" data-index-in-node="0">Directive:</b> “Revision of Guidelines for Dioxin Exposure Prevention in Waste Incineration Facilities”<br />
<b data-path-to-node="17,1,0" data-index-in-node="0">Scope:</b> For dioxin-exposure risk tasks classified as “Level 1.” (※)<br />
<b data-path-to-node="17,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified product (High airflow, PL3 or PS3).</p>
<p>(※) RL3 or RS3 dust masks may be used, but PAPR with higher protective performance is recommended.</p>
<h4 data-path-to-node="18"><b data-path-to-node="18" data-index-in-node="0">6. Handling Refractory Ceramic Fibers (RCF)</b></h4>
<p><b data-path-to-node="19,0,0" data-index-in-node="0">Regulation:</b> “Ordinance on Prevention of Hazards due to Specified Chemical Substances”<br />
<b data-path-to-node="19,1,0" data-index-in-node="0">Scope:</b> Insulation or fireproofing work involving the application of RCF to furnaces or boilers; or repair, dismantling, and demolition of such furnaces/boilers.<br />
<b data-path-to-node="19,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified product (PL3 or PS3).</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong>PAPR Standards</strong></th>
<td width="64">Beyond JIS standards, Powered Air-Purifying Respirators must adhere to standards defined under the Industrial Safety and Health Act. These comprehensive standards ensure that products are manufactured under strict safety requirements.</td>
</tr>
</tbody>
</table>
<p>The following table is excerpted from the ‘Standards for Powered Air-Purifying Respirators’</p>
<h3>Types of Powered Air-Purifying Respirators</h3>
<table>
<tbody>
<tr>
<th colspan="2"><strong>Powered Air-Purifying Particulate Respirator (P-PAPR)</strong></th>
</tr>
<tr>
<th rowspan="2"><strong>Powered Air-Purifying Gas Respirator (G-PAPR)</strong></th>
<td>Type with dust protection function</td>
</tr>
<tr>
<td>Type without dust protection function</td>
</tr>
</tbody>
</table>
<p><strong>■ Classification by Shape</strong></p>
<table>
<tbody>
<tr>
<th rowspan="2"><strong>Tight-fitting Facepiece</strong><br />
<span class="sub-item">・Full-face</span><br />
<span class="sub-item">・Half-face</span></th>
<td>Isolation type (with hose)</td>
</tr>
<tr>
<td>Direct connection type</td>
</tr>
<tr>
<th rowspan="2"><strong>Loose-fitting Facepiece</strong><br />
<span class="sub-item">・Hood</span><br />
<span class="sub-item">・Face shield</span></th>
<td>Isolation type (with hose)</td>
</tr>
<tr>
<td>Direct connection type</td>
</tr>
</tbody>
</table>
<p><strong>■ Classification by Performance</strong></p>
<table>
<thead>
<tr>
<th><strong>Airflow Performance Classification</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>Standard airflow type</td>
</tr>
<tr>
<td>High airflow type</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th><strong>Leakage Rate Performance Classification (P-PAPR)</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>Class B</td>
</tr>
<tr>
<td>Class A</td>
</tr>
<tr>
<td>Class S</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th colspan="2"><strong>Filter Material Performance Classification<br />
(P-PAPR and G-PAPR with dust function)</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td width="50%">PS1</td>
<td width="50%">PL1</td>
</tr>
<tr>
<td>PS2</td>
<td>PL2</td>
</tr>
<tr>
<td>PS3</td>
<td>PL3</td>
</tr>
</tbody>
</table>
<h3>Performance Testing for Powered Air-Purifying Respirators</h3>
<h4><strong>■ Particle Collection Efficiency Test</strong></h4>
<p>(Applies only to P-PAPR and G-PAPR with dust protection)</p>
<table>
<tbody>
<tr>
<th class="header-bg col-label" rowspan="3"><strong>Test Particle</strong></th>
<th class="header-bg col-sub"><strong>Type</strong></th>
<td class="align-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="align-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="header-bg"><strong>Particle Size</strong></th>
<td colspan="2">0.06μm ~ 0.1μm</td>
<td colspan="2">0.15μm ~ 0.25μm</td>
</tr>
<tr>
<th class="header-bg"><strong>Concentration</strong></th>
<td colspan="2">50mg/m³ or less</td>
<td colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="header-bg" rowspan="2"><strong>Test Flow Rate</strong></th>
<th class="header-bg"><strong>Standard Flow</strong></th>
<td colspan="4">104 L/min</td>
</tr>
<tr>
<th class="header-bg"><strong>High Flow</strong></th>
<td colspan="4">138 L/min</td>
</tr>
<tr>
<th class="header-bg align-left" colspan="2" rowspan="4"><strong>Collection Efficiency<br />
(Continuous measurement; must meet values in the right column)</strong></th>
<td colspan="2">For NaCl, loaded up to 200mg</td>
<td colspan="2">For DOP, loaded up to 400mg</td>
</tr>
<tr>
<td class="col-val">PS1</td>
<td class="col-res">95.0% or more</td>
<td class="col-val">PL1</td>
<td class="col-res">95.0% or more</td>
</tr>
<tr>
<td>PS2</td>
<td>99.0% or more</td>
<td>PL2</td>
<td>99.0% or more</td>
</tr>
<tr>
<td>PS3</td>
<td>99.97% or more</td>
<td>PL3</td>
<td>99.97% or more</td>
</tr>
</tbody>
</table>
<h4><strong>■ Canister Testing</strong></h4>
<p>(Applies only to G-PAPR)</p>
<table>
<tbody>
<tr>
<th><strong>Airtightness</strong></th>
<td class="align-left" colspan="4">No air leakage at 1470 Pa pressure</td>
</tr>
<tr>
<th rowspan="5"><strong>Decontamination Capacity<br />
(Time until breakthrough at specified concentration must be ≥ the right column)</strong></th>
<th><strong>Type</strong></th>
<th><strong>Test Gas</strong></th>
<th><strong>Breakthrough Concentration</strong></th>
<th><strong>Duration</strong></th>
</tr>
<tr>
<td>Halogen gas</td>
<td>Chlorine (0.02%)</td>
<td>1 ppm</td>
<td>40 mins or more</td>
</tr>
<tr>
<td>Organic gas</td>
<td>Cyclohexane (0.03%)</td>
<td>5 ppm</td>
<td>50 mins or more</td>
</tr>
<tr>
<td>Ammonia</td>
<td>Ammonia (0.1%)</td>
<td>50 ppm</td>
<td>40 mins or more</td>
</tr>
<tr>
<td>SO₂ gas</td>
<td>Sulfur dioxide (0.03%)</td>
<td>5 ppm</td>
<td>35 mins or more</td>
</tr>
<tr>
<th><strong>Leakage Concentration</strong></th>
<td class="align-left" colspan="4">At maximum flow rate, time to reach breakthrough must be ≥ 3 minutes.</td>
</tr>
</tbody>
</table>
<h4><strong>■ Inward Leakage Rate Test</strong></h4>
<table>
<colgroup>
<col />
<col />
<col />
<col /></colgroup>
<tbody>
<tr>
<th rowspan="3"><strong>Test Particle</strong></th>
<th><strong>Type</strong></th>
<td colspan="4">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<th><strong>Particle Size</strong></th>
<td colspan="4">0.06μm ~ 0.2μm</td>
</tr>
<tr>
<th><strong>Concentration</strong></th>
<td colspan="4">18mg/m³ or less</td>
</tr>
<tr>
<th rowspan="4"><strong>Simulated Breathing</strong></th>
<th><strong>Type</strong></th>
<td colspan="2">Standard Flow</td>
<td colspan="2">High Flow</td>
</tr>
<tr>
<th><strong>Waveform</strong></th>
<td colspan="4">Sine wave</td>
</tr>
<tr>
<th><strong>Ventilation Volume</strong></th>
<td colspan="2">1.5 ± 0.075 L/stroke</td>
<td colspan="2">1.6 ± 0.08 L/stroke</td>
</tr>
<tr>
<th><strong>Frequency</strong></th>
<td colspan="2">20 times/min</td>
<td colspan="2">25 times/min</td>
</tr>
<tr>
<th colspan="2" rowspan="4"><strong>Leakage Rate<br />
(2-minute continuous measurement; max value must meet the right column)</strong></th>
<td rowspan="3">P-PAPR</td>
<td>Class B</td>
<td colspan="2">5.0% or less</td>
</tr>
<tr>
<td>Class A</td>
<td colspan="2">1.0% or less</td>
</tr>
<tr>
<td>Class S</td>
<td colspan="2">0.1% or less</td>
</tr>
<tr>
<td>G-PAPR</td>
<td colspan="3">0.1% or less</td>
</tr>
<tr>
<th colspan="2" rowspan="4"><strong>Headform Movement<br />
(Calculate leakage rate for each item)</strong></th>
<th colspan="3"><strong>Position and Range</strong></th>
<th><strong>Frequency</strong></th>
</tr>
<tr>
<td rowspan="2">Head</td>
<td colspan="2">Front/Back 30 degrees</td>
<td>17 times/min</td>
</tr>
<tr>
<td colspan="2">Left/Right rotation 50 degrees</td>
<td>11 times/min</td>
</tr>
<tr>
<td>Arms</td>
<td colspan="2">Raising 10 ~ 130 degrees</td>
<td>7 times/min</td>
</tr>
</tbody>
</table>
<h4><strong>■ Other Tests</strong></h4>
<table>
<tbody>
<tr>
<th><strong>Internal Pressure<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">Under simulated breathing identical to the leakage test:<br />
0 Pa &lt; Internal Mask Pressure &lt; 400 Pa</td>
</tr>
<tr>
<th rowspan="2"><strong>Minimum Required Flow<br />
(Loose-fit only)</strong></th>
<td class="align-center">Standard Flow</td>
<td class="align-center">104 L/min or more</td>
</tr>
<tr>
<td class="align-center">High Flow</td>
<td class="align-center">138 L/min or more</td>
</tr>
<tr>
<th><strong>Inhalation Resistance<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">160 Pa or less<br />
(40 L/min flow rate, fan OFF)</td>
</tr>
<tr>
<th><strong>Exhalation Resistance<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">80 Pa or less<br />
(40 L/min flow rate, fan OFF)</td>
</tr>
<tr>
<th><strong>Exhalation Valve Airtightness<br />
(Tight-fitting only)</strong></th>
<td class="content-cell" colspan="2">・Internal pressure must drop immediately when air is sucked.<br />
・Time for pressure to return to normal must be ≥ 15 seconds.</td>
</tr>
<tr>
<th><strong>CO2 Concentration Increase<br />
(Tight-fitting only)</strong></th>
<td class="content-cell" colspan="2">With fan OFF, headform breathes CO2 air. Difference between wearing and not wearing mask must be &lt; 2.0%.</td>
</tr>
<tr>
<th><strong>Noise Level</strong></th>
<td class="align-center" colspan="2">Noise at the headform ear area must be below 80 dB (both sides).</td>
</tr>
<tr>
<th rowspan="4"><strong>Flow Rate<br />
(G-PAPR only)</strong></th>
<td>Max set average flow</td>
<td class="content-cell">Average must be ≤ the decontamination test flow rate.</td>
</tr>
<tr>
<td>Maximum flow</td>
<td class="content-cell">Maximum must be ≤ the flow rate set by the manufacturer.</td>
</tr>
<tr>
<th><strong>Tight-fitting type</strong></th>
<th><strong>Loose-fitting type</strong></th>
</tr>
<tr>
<td class="content-cell">Measure resistance with fan OFF/ON at 20~170 L/min to calculate flow per minute.</td>
<td class="content-cell">With fan ON, draw air for 5 mins to maintain normal pressure in chamber, then measure flow.</td>
</tr>
</tbody>
</table>
<h2>PAPR USE IS ENCOURAGED IN THE 10TH COMPREHENSIVE DUST HAZARD COUNTERMEASURES</h2>
<p><strong>To reduce pneumoconiosis, dust prevention measures must be strengthened.</strong></p>
<p>The “10th Comprehensive Countermeasures for Preventing Dust Hazards” demands the correct use of effective respiratory protection against dust exposure across all industries. PAPR is highlighted as a “more effective preventive measure for health impairment,” and its adoption is highly encouraged.<br />
The use of PAPR is more effective in preventing health impairment compared to standard dust masks due to its higher protection factor and reduced physical strain on the wearer.<br />
(Partial excerpt from the 10th Comprehensive Countermeasures)</p>
<p>Furthermore, due to high performance, PAPR is mandatory for specific tasks, but its use is also recommended for tasks outside the mandatory categories.<br />
While PAPR is mandatory for specific operations under the Dust Rules, its high performance makes it desirable for other tasks; thus, guidance and inspections encourage businesses to adopt PAPR for their workers.<br />
(Partial excerpt from the 10th Comprehensive Countermeasures)</p>
<h2>KOKEN BL SERIES BREATH-RESPONSIVE PAPR</h2>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Achieving “High Safety” and “Comfortable Fit” as expected</b></p>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">THE EVOLUTION OF THE BL SERIES</b></p>
<p data-path-to-node="6">The BL Series continues to evolve into the PAPR model that helps perfect safety and health management in every field, aligning with occupational health trends and market expansion.</p>
<p data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">CORE DEVELOPMENT FOCUS</b></p>
<ul>
<li data-path-to-node="8,0,0"><b data-path-to-node="8,0,0" data-index-in-node="0">“Safety”:</b> Improving the protection capability as a respirator.</li>
<li data-path-to-node="8,1,0"><b data-path-to-node="8,1,0" data-index-in-node="0">“Flow Technology”:</b> Minimizing waste and improving efficiency.</li>
<li data-path-to-node="8,2,0"><b data-path-to-node="8,2,0" data-index-in-node="0">“Lightweight Design”:</b> Reducing the burden on the worker.</li>
</ul>
<h2>KOKEN FLOW TECHNOLOGY: New BSFS air flow highly synchronized with breathing</h2>
<h3>THE MECHANISM OF THE BSFS (BREATH SYNCHRONIZED) SYSTEM</h3>
<p data-path-to-node="5">The BL Series is equipped with the Breath Synchronized-Air Flow System (new BSFS), which delivers airflow that follows the breathing rhythm more closely than ever, becoming a “Highly Synchronized” model.<br />
BSFS ELIMINATES THE FEELING OF BREATHLESSNESS/STUFFINESS<br />
<img loading="lazy" decoding="async" class="size-medium wp-image-191639 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-300x177.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-300x177.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4.jpg 464w" alt="" width="300" height="177" /></p>
<p><b data-path-to-node="2" data-index-in-node="0">THE BSFS MECHANISM HAS EVOLVED INTO “HIGH SYNCHRONIZATION”</b></p>
<p data-path-to-node="3">Using a fan equipped with a breath detection sensor, the device supplies “the necessary and sufficient amount of air” corresponding to the user’s inhalation. Responsiveness to breathing has been improved, and the accuracy of synchronization with the respiratory rhythm has significantly increased.<br />
<img loading="lazy" decoding="async" class="size-medium wp-image-191638 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-300x286.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-300x286.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-768x733.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1.jpg 1024w" alt="" width="300" height="286" /></p>
<h3>COMFORT UP</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">SOLVING MASK DISCOMFORT WITH FLOW THAT FOLLOWS EVERY BREATH</b></p>
<ul>
<li data-path-to-node="4,0,0">Reduces the physical workload for laborers.</li>
<li data-path-to-node="4,1,0">Solves breathing difficulties and stuffiness in high-temperature workplaces.</li>
</ul>
<h3>SAFETY UP</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">PREVENTING INWARD LEAKAGE THROUGH HIGH PROTECTION AND CONSTANT POSITIVE PRESSURE</b></p>
<p data-path-to-node="4,0,0">Breath Synchronization: Protection is guaranteed by the blower linked to breathing.</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class=" wp-image-191633 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-300x227.jpg" sizes="auto, (max-width: 441px) 100vw, 441px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-300x227.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-768x581.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6.jpg 1024w" alt="" width="441" height="334" /></td>
<td width="64"><img loading="lazy" decoding="async" class=" wp-image-191636 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-300x218.png" sizes="auto, (max-width: 508px) 100vw, 508px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-300x218.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-1024x745.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-768x559.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185.png 1407w" alt="" width="508" height="369" /></td>
</tr>
<tr>
<td height="19">
<p data-path-to-node="3,0,0"><b data-path-to-node="3,0,0" data-index-in-node="0">DURING INHALATION:</b> Air inside the mask is normally sucked away, but supplemental airflow prevents negative pressure. (If a gap exists, air blows outward ※1)</p>
<p data-path-to-node="3,0,0">※1: Airflow varies based on facepiece fit.</p>
</td>
<td>
<p data-path-to-node="3,1,0"><b data-path-to-node="3,1,0" data-index-in-node="0">DURING EXHALATION:</b> Since pressure doesn’t drop, airflow is reduced. This conserves the “filter” and “battery.”</p>
<p data-path-to-node="3,1,0">※2: Flow doesn’t stop completely (maintains a small amount for safety).</p>
</td>
</tr>
</tbody>
</table>
<p><b data-path-to-node="2" data-index-in-node="0">PAPR AVOIDS HIGH LEAKAGE RISKS FROM DUST BUILDUP IN LOOSE MASKS</b></p>
<p data-path-to-node="3">FOR CONVENTIONAL DUST MASKS:</p>
<p data-path-to-node="4">As dust builds on the filter, inhalation resistance increases, raising the risk of inward leakage. As dust accumulates, even if the gap remains the same, the leakage rate can double. (See diagram below)</p>
<p><img loading="lazy" decoding="async" class=" wp-image-191632 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-300x195.jpg" sizes="auto, (max-width: 409px) 100vw, 409px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-300x195.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-768x500.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-180x118.jpg 180w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8.jpg 1024w" alt="" width="409" height="266" /></p>
<p><b data-path-to-node="7" data-index-in-node="0">Leakage Measurement Method:</b> A 2.5% gap is created intentionally; NaCl concentration is measured inside/outside the mask with a digital meter.</p>
<h3>ECONOMY UP (ECO)</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">ELIMINATING WASTE THROUGH AN ECO FLOW MECHANISM</b></p>
<p data-path-to-node="4,0,0">Limits “wasteful dust buildup” and reduces filter usage: Minimizes air loss to reduce clogging.<br />
Limits battery usage: Extends runtime by reducing power consumption during low-respiration phases.</p>
<p><b data-path-to-node="2" data-index-in-node="0">BATTERY RUNTIME COMPARISON: NEW VS OLD BSFS</b></p>
<p data-path-to-node="3"><img loading="lazy" decoding="async" class=" wp-image-191631 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/1-300x126.png" sizes="auto, (max-width: 445px) 100vw, 445px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/1-300x126.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-1024x429.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-768x322.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/1.png 1536w" alt="" width="445" height="187" /></p>
<p data-path-to-node="3"><strong>ECO FLOW CREATED BY HIGH SYNCHRONIZATION</strong></p>
<p data-path-to-node="3"><img loading="lazy" decoding="async" class=" wp-image-191630 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/2-300x175.png" sizes="auto, (max-width: 456px) 100vw, 456px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/2-300x175.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-1024x599.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-768x449.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/2.png 1536w" alt="" width="456" height="266" />Image of BSFS flow following actual respiratory waveforms with high precision.</p>
<h2 data-path-to-node="3">KOKEN LIGHTWEIGHT DESIGN: Reducing burden for long shifts</h2>
<p>The “BL Series” optimizes compact sizing and weight equivalent to conventional dust masks. It is highly rated in tunnel construction, asbestos handling, and arc welding.</p>
<p><b data-path-to-node="4" data-index-in-node="0">SEPARATE TYPE</b> Because a direct-mounted battery adds weight to the neck, the separate design reduces perceived weight. This ultra-lightweight design minimizes mask body thickness.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56541" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-122956.png" sizes="auto, (max-width: 348px) 100vw, 348px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-122956.png 594w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-122956-300x261.png 300w" alt="" width="348" height="302" /></p>
<p><b data-path-to-node="5" data-index-in-node="0">BUILT-IN TYPE</b> Thanks to “High Synchro” BSFS reducing power draw, battery size has been shrunk. This results in a lightweight built-in battery design with minimal burden.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56542" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123026.png" sizes="auto, (max-width: 212px) 100vw, 212px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123026.png 310w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123026-236x300.png 236w" alt="" width="212" height="269" /></p>
<h2>KOKEN SAFETY DESIGN: Internal pressure monitoring to maintain positive pressure</h2>
<p data-path-to-node="3">(Common for BL-321/BL-351/BL-351X/BL-711/BL-700/BL-200/BL-100 series)</p>
<p data-path-to-node="4">Modern worksites require PAPRs that “constantly monitor internal pressure and provide alerts.”<br />
PAPR is most protective under positive pressure; therefore, the moment positive pressure cannot be maintained is the filter replacement time. “Internal monitoring” notifies the user when pressure drops due to weak flow.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56543" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123245.png" sizes="auto, (max-width: 243px) 100vw, 243px" srcset="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123245.png 358w, https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123245-289x300.png 289w" alt="" width="243" height="253" /></p>
<p data-path-to-node="7,0,0">■ Positive pressure inside the mask can be maintained through timely/appropriate filter replacement.<br />
■ Clarifies the standard for filter replacement – which is otherwise often vague or based on subjective estimation.<br />
■ Full airflow can be restored through proper battery charging.</p>
<p><b data-path-to-node="2" data-index-in-node="0">NOTIFICATION VIA AIRFLOW</b></p>
<p data-path-to-node="3">(For BL-321 / BL-351 / BL-351X / BL-711 series)</p>
<ul>
<li data-path-to-node="4,0,0">Pressure drop warning via “Continuous Airflow”: ➔ Replace the filter.</li>
<li data-path-to-node="4,1,0">Low battery warning via “Rhythmic Airflow”: ➔ Replace with a charged battery.</li>
</ul>
<p><b data-path-to-node="6" data-index-in-node="0">LED NOTIFICATION</b></p>
<p data-path-to-node="7">(For BL-700 / BL-200 / BL-100 series)</p>
<ul>
<li data-path-to-node="8,0,0">Pressure drop warning via “Flashing LED”: ➔ Replace the filter.</li>
<li data-path-to-node="8,1,0">Low battery warning via “Steady LED”: ➔ Replace with a charged battery.</li>
</ul>
<p><img loading="lazy" decoding="async" class=" wp-image-191629 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/3-300x65.png" sizes="auto, (max-width: 471px) 100vw, 471px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/3-300x65.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-1024x221.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-768x166.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/3.png 1536w" alt="" width="471" height="102" /></p>
<h2>POWERED AIR-PURIFYING PARTICULATE RESPIRATOR (P-PAPR)</h2>
<p>[FULL FACEPIECE TYPE]</p>
<h3>BL-700 SERIES</h3>
<p>PAPR full-face model with high protective performance, highly successful in asbestos removal operations.</p>
<p data-path-to-node="4,0,0"><b data-path-to-node="4,0,0" data-index-in-node="0">Classification:</b> <b data-path-to-node="4,0,0" data-index-in-node="11">HIGH AIRFLOW TYPE</b></p>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Key Features:</b></p>
<ul>
<li data-path-to-node="6,0,0">High Synchro</li>
<li data-path-to-node="6,1,0">Internal Pressure Monitoring</li>
<li data-path-to-node="6,2,0">HAWC Lip</li>
<li data-path-to-node="6,3,0">Speaking Diaphragm</li>
<li data-path-to-node="6,4,0">Surface Hardening</li>
</ul>
<p>■ Constant positive pressure management via internal monitoring.</p>
<p data-path-to-node="1,0,0"><img loading="lazy" decoding="async" class=" wp-image-192540 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-300x164.jpg" alt="" width="379" height="207" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-300x164.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-768x419.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9.jpg 1024w" sizes="auto, (max-width: 379px) 100vw, 379px" /></p>
<p>■ Integrated speaking diaphragm for clear communication.</p>
<h3>Sakai Model BL-700HA-03</h3>
<p>Includes battery &amp; charger. Pattern Test Cert TP20</p>
<p data-path-to-node="1,1,0"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56567" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_142222-removebg-preview.png" alt="" width="476" height="391" /></p>
<ul>
<li data-path-to-node="1,0,0">PL3 efficiency</li>
<li data-path-to-node="1,1,0">Class S leakage</li>
<li data-path-to-node="1,2,0">Assigned Protection Factor: 1000</li>
<li data-path-to-node="1,3,0">Asbestos removal</li>
<li data-path-to-node="1,4,0">Indium handling</li>
<li data-path-to-node="1,5,0">RCF handling</li>
<li data-path-to-node="1,6,0">Dioxin (Level 1)</li>
</ul>
<p data-path-to-node="2"><b data-path-to-node="2" data-index-in-node="0">Replacement Filter: </b>Alpha Ring Filter BRD-7</p>
<p data-path-to-node="4"><b data-path-to-node="4" data-index-in-node="0">Options:</b></p>
<ul>
<li data-path-to-node="5,0,0">High Scope V-type glasses: Specialized glasses that do not compromise the mask seal.</li>
<li data-path-to-node="5,1,0">HV vision protector: To protect eyewear.</li>
</ul>
<h3>Sakai Model BL-700U-03</h3>
<p>Includes battery &amp; charger. Pattern Test Cert TP21<br />
<img loading="lazy" decoding="async" class="wp-image-192542 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-1-1-300x224.jpg" alt="" width="407" height="304" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-1-1-300x224.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-1-1-768x574.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-1-1.jpg 1024w" sizes="auto, (max-width: 407px) 100vw, 407px" /></p>
<ul>
<li data-path-to-node="2,0,0">PL3 efficiency</li>
<li data-path-to-node="2,1,0">Class S leakage</li>
<li data-path-to-node="2,2,0">Assigned Protection Factor: 1000</li>
<li data-path-to-node="2,3,0">Nanomaterial handling</li>
</ul>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Replacement Filter: </b>Alpha Ring Filter BRD-8U</p>
<p data-path-to-node="1"><b data-path-to-node="1" data-index-in-node="0">BL-700HA includes parts suitable for asbestos removal</b></p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><b data-path-to-node="2,0,0" data-index-in-node="0">Waterproof cover:</b> Protects battery unit from moisture and sweat.</td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56569" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-142750.png" alt="" width="107" height="132" /></td>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><b data-path-to-node="2,1,0" data-index-in-node="0">BL fan unit cover:</b> Prevents dust from entering the fan.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56570" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-142758.png" alt="" width="113" height="112" /></td>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><b data-path-to-node="2,2,0" data-index-in-node="0">Moisture sponge Type E:</b> Absorbs condensation and sweat inside the mask.</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56571" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-142806.png" alt="" width="119" height="110" /></td>
</tr>
</tbody>
</table>
<h3>Performance Specifications</h3>
<table class="spec-table">
<thead>
<tr>
<th rowspan="2"><strong>Product Name</strong></th>
<th colspan="3"><strong>Classification</strong></th>
<th rowspan="2"><strong>Collection Efficiency</strong></th>
<th rowspan="2"><strong>Weight (incl. battery)</strong></th>
<th rowspan="2"><strong>Facepiece Weight</strong></th>
<th rowspan="2"><strong>Battery Specs</strong></th>
<th rowspan="2"><strong>Nominal Runtime*1</strong></th>
<th rowspan="2"><strong>Actual Runtime*2</strong></th>
<th rowspan="2"><strong>Fan Lifespan</strong></th>
</tr>
<tr>
<th><strong>Fan Type</strong></th>
<th><strong>Leakage Rate</strong></th>
<th><strong>Filter Grade</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td class="product">BL-711H</td>
<td rowspan="4">High Airflow</td>
<td rowspan="4">Class S (≤0.1%)</td>
<td rowspan="4">PL3</td>
<td>99.97% or more</td>
<td colspan="2">≤753g (Avg 723g)</td>
<td class="left" rowspan="4">Li-ion Rechargeable<br />
Voltage: 7.2V<br />
Capacity: 2000mAh<br />
Charging: ~3 hours*3<br />
Cycles: ~300 times*3</td>
<td rowspan="2">Approx. 6 hours</td>
<td rowspan="2">Approx. 6.5–10 hours</td>
<td rowspan="20">Approx. 2,000 hours*3</td>
</tr>
<tr>
<td class="product">BL-711U</td>
<td>99.99% or more</td>
<td colspan="2">≤753g (Avg 720g)</td>
</tr>
<tr>
<td class="product">BL-700HA</td>
<td>99.97% or more</td>
<td rowspan="2">≤774g</td>
<td rowspan="2">Avg 591g</td>
<td rowspan="2">Approx. 7.5 hours</td>
<td rowspan="2">Approx. 8–14.5 hours</td>
</tr>
<tr>
<td class="product">BL-700U</td>
<td>99.99% or more</td>
</tr>
</tbody>
</table>
<h3>Key Features:</h3>
<ul>
<li data-path-to-node="2,0,0"><b data-path-to-node="2,0,0" data-index-in-node="0">High Synchro:</b> Next-generation model improves airflow efficiency and tracks user breathing rhythm more accurately.</li>
<li data-path-to-node="2,1,0"><b data-path-to-node="2,1,0" data-index-in-node="0">Fit Checker:</b> Easily perform a fit test by simply pulling the lever.</li>
<li data-path-to-node="2,2,0"><b data-path-to-node="2,2,0" data-index-in-node="0">Under Chin:</b> Unique curved design enhances the airtight seal at the face contact area.</li>
<li data-path-to-node="2,3,0"><b data-path-to-node="2,3,0" data-index-in-node="0">Micron:</b> High-performance electrostatic filter. This mask utilizes Micron filter technology.</li>
<li data-path-to-node="2,4,0"><b data-path-to-node="2,4,0" data-index-in-node="0">Speaker:</b> Integrated communication speaker ensures clear dialogue while wearing the mask.</li>
<li data-path-to-node="2,5,0"><b data-path-to-node="2,5,0" data-index-in-node="0">Special Hard Coating:</b> Improved scratch resistance compared to standard surface hardening methods.</li>
<li data-path-to-node="2,6,0"><b data-path-to-node="2,6,0" data-index-in-node="0">Silicone:</b> The facepiece uses high-grade silicone material for a soft, skin-friendly fit.</li>
<li data-path-to-node="2,7,0"><b data-path-to-node="2,7,0" data-index-in-node="0">Speaking Diaphragm:</b> Facilitates clear communication and instruction without mask removal.</li>
<li data-path-to-node="2,8,0"><b data-path-to-node="2,8,0" data-index-in-node="0">Internal Pressure Monitoring:</b> Flashing light alerts the user when positive pressure is lost inside the facepiece.</li>
<li data-path-to-node="2,9,0"><b data-path-to-node="2,9,0" data-index-in-node="0">HAWC Lip:</b> Full-face models use the HAWC Lip structure for a high-seal &#8220;suction cup effect.&#8221;</li>
<li data-path-to-node="2,10,0"><b data-path-to-node="2,10,0" data-index-in-node="0">Hardened Eyepiece:</b> The visor surface is treated with a hardening process to resist scratches.</li>
</ul>The post <a href="https://koueitrading.com/global/product/koken-bl-700-series-p-papr/">Koken BL-700 Series P-PAPR</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken BL-1005 Series P-PAPR</title>
		<link>https://koueitrading.com/global/product/koken-bl-1005-series-p-papr/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 12 Mar 2020 03:37:07 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192531</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: BL-1005 Series P-PAPR: Powered Air-Purifying Particulate Respirator PARTICULATE PAPR and GAS PAPR PAPR: Powered Air-Purifying Respirator. P-PAPR: Particulate PAPR (Used for dust/particles). G-PAPR: Gas PAPR (Used for toxic gases/vapors). Within the PAPR range, there are “Powered Air-Purifying Particulate Respirators (P-PAPR)” for dust hazards and “Powered Air-Purifying Gas Respirators (G-PAPR)” for toxic [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-bl-1005-series-p-papr/">Koken BL-1005 Series P-PAPR</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: BL-1005 Series</p>
<p>P-PAPR: Powered Air-Purifying Particulate Respirator</p>
<h2>PARTICULATE PAPR and GAS PAPR</h2>
<ul>
<li data-path-to-node="14,0,0">PAPR: Powered Air-Purifying Respirator.</li>
<li data-path-to-node="14,1,0">P-PAPR: Particulate PAPR (Used for dust/particles).</li>
<li data-path-to-node="14,2,0">G-PAPR: Gas PAPR (Used for toxic gases/vapors).</li>
</ul>
<p data-path-to-node="3">Within the PAPR range, there are “Powered Air-Purifying Particulate Respirators (P-PAPR)” for dust hazards and “Powered Air-Purifying Gas Respirators (G-PAPR)” for toxic gas hazards. It is essential to understand the properties, type, and concentration of the hazardous substances before selecting the appropriate mask.</p>
<p data-path-to-node="3">To prevent inhalation of DUST -&gt; Use a Powered Air-Purifying Particulate Respirator (P-PAPR)<br />
To prevent inhalation of TOXIC GAS -&gt; Use a Powered Air-Purifying Gas Respirator (G-PAPR)<br />
To prevent inhalation of MIXED DUST &amp; TOXIC GAS -&gt; Use a Powered Air-Purifying Gas Respirator (G-PAPR) with dust protection function</p>
<h3>Environments where PAPR CANNOT be used</h3>
<p data-path-to-node="9">PAPR must not be used if any of the following conditions apply. Please use respiratory protective equipment suitable for the environment, such as a supplied-air respirator or a self-contained breathing apparatus (SCBA).</p>
<ul>
<li data-path-to-node="10,0,0">Oxygen-deficient environments or those at risk of oxygen deficiency (Oxygen concentration below 18%).</li>
<li data-path-to-node="10,1,0">Cases where the type or concentration of the toxic gas is unknown.</li>
<li data-path-to-node="10,2,0">IDLH environments (Atmospheres Immediately Dangerous to Life or Health).</li>
<li data-path-to-node="10,2,0">Cases where the toxic gas concentration exceeds the permissible limit for the PAPR. ※</li>
<li data-path-to-node="10,3,0">Cases where no filter (canister) is available to remove the specific toxic gas in the environment.</li>
<li data-path-to-node="10,4,0">Cases where a mixture of gases with different properties exists.</li>
<li data-path-to-node="10,5,0">Cases where the environment deviates significantly from normal temperature, humidity, and atmospheric pressure.</li>
</ul>
<p data-path-to-node="11">(※ According to standards based on the Industrial Safety and Health Act, the application range of G-PAPR is 2% (3% for Ammonia))</p>
<h3>SELECTING THE APPROPRIATE PAPR BASED ON HAZARD CONCENTRATION</h3>
<p data-path-to-node="3">Determine the Required Protection Factor, then select a PAPR model with an Assigned Protection Factor higher than that value.</p>
<p data-path-to-node="4,0">Formula: How to calculate the Required Protection Factor<br />
<strong>Required Protection Factor = Ambient concentration of identified hazard / Permissible exposure limit of the hazard</strong></p>
<p>Assigned Protection Factor of P-PAPR</p>
<table>
<thead>
<tr>
<th colspan="2"><strong>Classification</strong></th>
<th colspan="4"><strong>Facepiece Type</strong></th>
</tr>
<tr>
<th><strong>Leakage Rate</strong></th>
<th><strong>Filter Efficiency</strong></th>
<th><strong>Half-face</strong></th>
<th><strong>Full-face</strong></th>
<th><strong>Hood Type</strong></th>
<th><strong>Face shield</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td rowspan="3">Class S</td>
<td>PL3/PS3</td>
<td>50/300</td>
<td>1000</td>
<td>25/1000</td>
<td>25/300</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>—</td>
<td>—</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td rowspan="3">Class A</td>
<td>PL3/PS3</td>
<td>—</td>
<td>—</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>33</td>
<td>90</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>14</td>
<td>19</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td rowspan="3">Class B</td>
<td>PL3/PS3</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>14</td>
<td>19</td>
<td>11</td>
<td>11</td>
</tr>
</tbody>
</table>
<p>Assigned Protection Factor of G-PAPR</p>
<table>
<thead>
<tr>
<th class="header-main" colspan="4"><strong>Facepiece Type</strong></th>
</tr>
<tr>
<th><strong>Half-face</strong></th>
<th><strong>Full-face</strong></th>
<th><strong>Hood Type</strong></th>
<th><strong>Face shield</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>50/300</td>
<td>1000</td>
<td>25/1000</td>
<td>25/300</td>
</tr>
</tbody>
</table>
<p>For “G-PAPR with dust protection function,” please refer to the Assigned Protection Factor of P-PAPR (Class S leakage rate) mentioned above for dust (and similar particulates).</p>
<h2>TASKS WHERE PAPR USE IS MANDATORY BY REGULATION OR DIRECTIVE</h2>
<p><strong>For tasks where PAPR use is mandatory by regulation or directive, please use a PAPR with the designated performance classification.</strong></p>
<h4><strong>1. Tunnel Construction Work</strong></h4>
<p><strong>Regulation:</strong> “Ordinance on Prevention of Pneumoconiosis”<br />
<strong>Scope:</strong> In tunnel construction, at locations involving “mechanical/powered excavation,” “mechanical loading or unloading of ore/rock,” and “shotcreting.”</p>
<p><strong>PAPR Requirements:</strong></p>
<ul>
<li>National test certified product (High airflow type).</li>
<li>Tight-fitting facepiece type where the battery can be removed for use during blasting operations.</li>
</ul>
<h4><strong>2. Asbestos Removal Work</strong></h4>
<p><strong>Regulation:</strong> “Ordinance on Prevention of Health Impairment due to Asbestos”<br />
<strong>Scope</strong>: In asbestos removal tasks, specifically those requiring “Class 1 Asbestos Removal Masks.”<br />
<b data-path-to-node="11,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified tight-fitting or hood types (High airflow, Class S, PL3 or PS3).</p>
<h4 data-path-to-node="12"><b data-path-to-node="12" data-index-in-node="0">3. Handling Nanomaterials</b></h4>
<p data-path-to-node="13,0,0"><b data-path-to-node="13,0,0" data-index-in-node="0">Directive:</b> “Regarding Preventive Measures for Exposure to Nanomaterials”<br />
<b data-path-to-node="13,1,0" data-index-in-node="0">Scope:</b> Manufacturing and handling of nanomaterials. (※)<br />
<b data-path-to-node="13,2,0" data-index-in-node="0">PAPR Requirements:</b></p>
<ul>
<li data-path-to-node="13,2,0">National test certified product (High airflow, PL3 or PS3).</li>
<li data-path-to-node="13,2,1,0,0">Shape limitations based on the projected exposure levels of workers.</li>
</ul>
<p data-path-to-node="13,2,1,1,0">(※) Depending on the work environment, respiratory protective equipment other than PAPR may be used.</p>
<h4 data-path-to-node="14"><b data-path-to-node="14" data-index-in-node="0">4. Handling Indium</b></h4>
<p data-path-to-node="15,0,0"><b data-path-to-node="15,0,0" data-index-in-node="0">Directive:</b> “Regarding Thorough Health Hazard Prevention Measures for Indium/Tin Oxide Handling”<br />
<b data-path-to-node="15,1,0" data-index-in-node="0">Scope:</b> Handling of Indium, Tin Oxide, etc. (※)<br />
<b data-path-to-node="15,2,0" data-index-in-node="0">PAPR Requirements:</b></p>
<ul>
<li data-path-to-node="15,2,0">National test certified product (High airflow, PL3 or PS3).</li>
<li data-path-to-node="15,2,1,0,0">Limitations on shape and leakage rate based on working environment measurement results.</li>
</ul>
<p data-path-to-node="15,2,1,1,0">(※) Depending on environmental results, respiratory protective equipment other than PAPR may be used.</p>
<h4 data-path-to-node="16"><b data-path-to-node="16" data-index-in-node="0">5. Handling Dioxins</b></h4>
<p><b data-path-to-node="17,0,0" data-index-in-node="0">Directive:</b> “Revision of Guidelines for Dioxin Exposure Prevention in Waste Incineration Facilities”<br />
<b data-path-to-node="17,1,0" data-index-in-node="0">Scope:</b> For dioxin-exposure risk tasks classified as “Level 1.” (※)<br />
<b data-path-to-node="17,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified product (High airflow, PL3 or PS3).</p>
<p>(※) RL3 or RS3 dust masks may be used, but PAPR with higher protective performance is recommended.</p>
<h4 data-path-to-node="18"><b data-path-to-node="18" data-index-in-node="0">6. Handling Refractory Ceramic Fibers (RCF)</b></h4>
<p><b data-path-to-node="19,0,0" data-index-in-node="0">Regulation:</b> “Ordinance on Prevention of Hazards due to Specified Chemical Substances”<br />
<b data-path-to-node="19,1,0" data-index-in-node="0">Scope:</b> Insulation or fireproofing work involving the application of RCF to furnaces or boilers; or repair, dismantling, and demolition of such furnaces/boilers.<br />
<b data-path-to-node="19,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified product (PL3 or PS3).</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong>PAPR Standards</strong></th>
<td width="64">Beyond JIS standards, Powered Air-Purifying Respirators must adhere to standards defined under the Industrial Safety and Health Act. These comprehensive standards ensure that products are manufactured under strict safety requirements.</td>
</tr>
</tbody>
</table>
<p>The following table is excerpted from the ‘Standards for Powered Air-Purifying Respirators’</p>
<h3>Types of Powered Air-Purifying Respirators</h3>
<table>
<tbody>
<tr>
<th colspan="2"><strong>Powered Air-Purifying Particulate Respirator (P-PAPR)</strong></th>
</tr>
<tr>
<th rowspan="2"><strong>Powered Air-Purifying Gas Respirator (G-PAPR)</strong></th>
<td>Type with dust protection function</td>
</tr>
<tr>
<td>Type without dust protection function</td>
</tr>
</tbody>
</table>
<p><strong>■ Classification by Shape</strong></p>
<table>
<tbody>
<tr>
<th rowspan="2"><strong>Tight-fitting Facepiece</strong><br />
<span class="sub-item">・Full-face</span><br />
<span class="sub-item">・Half-face</span></th>
<td>Isolation type (with hose)</td>
</tr>
<tr>
<td>Direct connection type</td>
</tr>
<tr>
<th rowspan="2"><strong>Loose-fitting Facepiece</strong><br />
<span class="sub-item">・Hood</span><br />
<span class="sub-item">・Face shield</span></th>
<td>Isolation type (with hose)</td>
</tr>
<tr>
<td>Direct connection type</td>
</tr>
</tbody>
</table>
<p><strong>■ Classification by Performance</strong></p>
<table>
<thead>
<tr>
<th><strong>Airflow Performance Classification</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>Standard airflow type</td>
</tr>
<tr>
<td>High airflow type</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th><strong>Leakage Rate Performance Classification (P-PAPR)</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>Class B</td>
</tr>
<tr>
<td>Class A</td>
</tr>
<tr>
<td>Class S</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th colspan="2"><strong>Filter Material Performance Classification<br />
(P-PAPR and G-PAPR with dust function)</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td width="50%">PS1</td>
<td width="50%">PL1</td>
</tr>
<tr>
<td>PS2</td>
<td>PL2</td>
</tr>
<tr>
<td>PS3</td>
<td>PL3</td>
</tr>
</tbody>
</table>
<h3>Performance Testing for Powered Air-Purifying Respirators</h3>
<h4><strong>■ Particle Collection Efficiency Test</strong></h4>
<p>(Applies only to P-PAPR and G-PAPR with dust protection)</p>
<table>
<tbody>
<tr>
<th class="header-bg col-label" rowspan="3"><strong>Test Particle</strong></th>
<th class="header-bg col-sub"><strong>Type</strong></th>
<td class="align-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="align-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="header-bg"><strong>Particle Size</strong></th>
<td colspan="2">0.06μm ~ 0.1μm</td>
<td colspan="2">0.15μm ~ 0.25μm</td>
</tr>
<tr>
<th class="header-bg"><strong>Concentration</strong></th>
<td colspan="2">50mg/m³ or less</td>
<td colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="header-bg" rowspan="2"><strong>Test Flow Rate</strong></th>
<th class="header-bg"><strong>Standard Flow</strong></th>
<td colspan="4">104 L/min</td>
</tr>
<tr>
<th class="header-bg"><strong>High Flow</strong></th>
<td colspan="4">138 L/min</td>
</tr>
<tr>
<th class="header-bg align-left" colspan="2" rowspan="4"><strong>Collection Efficiency<br />
(Continuous measurement; must meet values in the right column)</strong></th>
<td colspan="2">For NaCl, loaded up to 200mg</td>
<td colspan="2">For DOP, loaded up to 400mg</td>
</tr>
<tr>
<td class="col-val">PS1</td>
<td class="col-res">95.0% or more</td>
<td class="col-val">PL1</td>
<td class="col-res">95.0% or more</td>
</tr>
<tr>
<td>PS2</td>
<td>99.0% or more</td>
<td>PL2</td>
<td>99.0% or more</td>
</tr>
<tr>
<td>PS3</td>
<td>99.97% or more</td>
<td>PL3</td>
<td>99.97% or more</td>
</tr>
</tbody>
</table>
<h4><strong>■ Canister Testing</strong></h4>
<p>(Applies only to G-PAPR)</p>
<table>
<tbody>
<tr>
<th><strong>Airtightness</strong></th>
<td class="align-left" colspan="4">No air leakage at 1470 Pa pressure</td>
</tr>
<tr>
<th rowspan="5"><strong>Decontamination Capacity<br />
(Time until breakthrough at specified concentration must be ≥ the right column)</strong></th>
<th><strong>Type</strong></th>
<th><strong>Test Gas</strong></th>
<th><strong>Breakthrough Concentration</strong></th>
<th><strong>Duration</strong></th>
</tr>
<tr>
<td>Halogen gas</td>
<td>Chlorine (0.02%)</td>
<td>1 ppm</td>
<td>40 mins or more</td>
</tr>
<tr>
<td>Organic gas</td>
<td>Cyclohexane (0.03%)</td>
<td>5 ppm</td>
<td>50 mins or more</td>
</tr>
<tr>
<td>Ammonia</td>
<td>Ammonia (0.1%)</td>
<td>50 ppm</td>
<td>40 mins or more</td>
</tr>
<tr>
<td>SO₂ gas</td>
<td>Sulfur dioxide (0.03%)</td>
<td>5 ppm</td>
<td>35 mins or more</td>
</tr>
<tr>
<th><strong>Leakage Concentration</strong></th>
<td class="align-left" colspan="4">At maximum flow rate, time to reach breakthrough must be ≥ 3 minutes.</td>
</tr>
</tbody>
</table>
<h4><strong>■ Inward Leakage Rate Test</strong></h4>
<table>
<colgroup>
<col />
<col />
<col />
<col /></colgroup>
<tbody>
<tr>
<th rowspan="3"><strong>Test Particle</strong></th>
<th><strong>Type</strong></th>
<td colspan="4">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<th><strong>Particle Size</strong></th>
<td colspan="4">0.06μm ~ 0.2μm</td>
</tr>
<tr>
<th><strong>Concentration</strong></th>
<td colspan="4">18mg/m³ or less</td>
</tr>
<tr>
<th rowspan="4"><strong>Simulated Breathing</strong></th>
<th><strong>Type</strong></th>
<td colspan="2">Standard Flow</td>
<td colspan="2">High Flow</td>
</tr>
<tr>
<th><strong>Waveform</strong></th>
<td colspan="4">Sine wave</td>
</tr>
<tr>
<th><strong>Ventilation Volume</strong></th>
<td colspan="2">1.5 ± 0.075 L/stroke</td>
<td colspan="2">1.6 ± 0.08 L/stroke</td>
</tr>
<tr>
<th><strong>Frequency</strong></th>
<td colspan="2">20 times/min</td>
<td colspan="2">25 times/min</td>
</tr>
<tr>
<th colspan="2" rowspan="4"><strong>Leakage Rate<br />
(2-minute continuous measurement; max value must meet the right column)</strong></th>
<td rowspan="3">P-PAPR</td>
<td>Class B</td>
<td colspan="2">5.0% or less</td>
</tr>
<tr>
<td>Class A</td>
<td colspan="2">1.0% or less</td>
</tr>
<tr>
<td>Class S</td>
<td colspan="2">0.1% or less</td>
</tr>
<tr>
<td>G-PAPR</td>
<td colspan="3">0.1% or less</td>
</tr>
<tr>
<th colspan="2" rowspan="4"><strong>Headform Movement<br />
(Calculate leakage rate for each item)</strong></th>
<th colspan="3"><strong>Position and Range</strong></th>
<th><strong>Frequency</strong></th>
</tr>
<tr>
<td rowspan="2">Head</td>
<td colspan="2">Front/Back 30 degrees</td>
<td>17 times/min</td>
</tr>
<tr>
<td colspan="2">Left/Right rotation 50 degrees</td>
<td>11 times/min</td>
</tr>
<tr>
<td>Arms</td>
<td colspan="2">Raising 10 ~ 130 degrees</td>
<td>7 times/min</td>
</tr>
</tbody>
</table>
<h4><strong>■ Other Tests</strong></h4>
<table>
<tbody>
<tr>
<th><strong>Internal Pressure<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">Under simulated breathing identical to the leakage test:<br />
0 Pa &lt; Internal Mask Pressure &lt; 400 Pa</td>
</tr>
<tr>
<th rowspan="2"><strong>Minimum Required Flow<br />
(Loose-fit only)</strong></th>
<td class="align-center">Standard Flow</td>
<td class="align-center">104 L/min or more</td>
</tr>
<tr>
<td class="align-center">High Flow</td>
<td class="align-center">138 L/min or more</td>
</tr>
<tr>
<th><strong>Inhalation Resistance<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">160 Pa or less<br />
(40 L/min flow rate, fan OFF)</td>
</tr>
<tr>
<th><strong>Exhalation Resistance<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">80 Pa or less<br />
(40 L/min flow rate, fan OFF)</td>
</tr>
<tr>
<th><strong>Exhalation Valve Airtightness<br />
(Tight-fitting only)</strong></th>
<td class="content-cell" colspan="2">・Internal pressure must drop immediately when air is sucked.<br />
・Time for pressure to return to normal must be ≥ 15 seconds.</td>
</tr>
<tr>
<th><strong>CO2 Concentration Increase<br />
(Tight-fitting only)</strong></th>
<td class="content-cell" colspan="2">With fan OFF, headform breathes CO2 air. Difference between wearing and not wearing mask must be &lt; 2.0%.</td>
</tr>
<tr>
<th><strong>Noise Level</strong></th>
<td class="align-center" colspan="2">Noise at the headform ear area must be below 80 dB (both sides).</td>
</tr>
<tr>
<th rowspan="4"><strong>Flow Rate<br />
(G-PAPR only)</strong></th>
<td>Max set average flow</td>
<td class="content-cell">Average must be ≤ the decontamination test flow rate.</td>
</tr>
<tr>
<td>Maximum flow</td>
<td class="content-cell">Maximum must be ≤ the flow rate set by the manufacturer.</td>
</tr>
<tr>
<th><strong>Tight-fitting type</strong></th>
<th><strong>Loose-fitting type</strong></th>
</tr>
<tr>
<td class="content-cell">Measure resistance with fan OFF/ON at 20~170 L/min to calculate flow per minute.</td>
<td class="content-cell">With fan ON, draw air for 5 mins to maintain normal pressure in chamber, then measure flow.</td>
</tr>
</tbody>
</table>
<h2>PAPR USE IS ENCOURAGED IN THE 10TH COMPREHENSIVE DUST HAZARD COUNTERMEASURES</h2>
<p><strong>To reduce pneumoconiosis, dust prevention measures must be strengthened.</strong></p>
<p>The “10th Comprehensive Countermeasures for Preventing Dust Hazards” demands the correct use of effective respiratory protection against dust exposure across all industries. PAPR is highlighted as a “more effective preventive measure for health impairment,” and its adoption is highly encouraged.<br />
The use of PAPR is more effective in preventing health impairment compared to standard dust masks due to its higher protection factor and reduced physical strain on the wearer.<br />
(Partial excerpt from the 10th Comprehensive Countermeasures)</p>
<p>Furthermore, due to high performance, PAPR is mandatory for specific tasks, but its use is also recommended for tasks outside the mandatory categories.<br />
While PAPR is mandatory for specific operations under the Dust Rules, its high performance makes it desirable for other tasks; thus, guidance and inspections encourage businesses to adopt PAPR for their workers.<br />
(Partial excerpt from the 10th Comprehensive Countermeasures)</p>
<h2>KOKEN BL SERIES BREATH-RESPONSIVE PAPR</h2>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Achieving “High Safety” and “Comfortable Fit” as expected</b></p>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">THE EVOLUTION OF THE BL SERIES</b></p>
<p data-path-to-node="6">The BL Series continues to evolve into the PAPR model that helps perfect safety and health management in every field, aligning with occupational health trends and market expansion.</p>
<p data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">CORE DEVELOPMENT FOCUS</b></p>
<ul>
<li data-path-to-node="8,0,0"><b data-path-to-node="8,0,0" data-index-in-node="0">“Safety”:</b> Improving the protection capability as a respirator.</li>
<li data-path-to-node="8,1,0"><b data-path-to-node="8,1,0" data-index-in-node="0">“Flow Technology”:</b> Minimizing waste and improving efficiency.</li>
<li data-path-to-node="8,2,0"><b data-path-to-node="8,2,0" data-index-in-node="0">“Lightweight Design”:</b> Reducing the burden on the worker.</li>
</ul>
<h2>KOKEN FLOW TECHNOLOGY: New BSFS air flow highly synchronized with breathing</h2>
<h3>THE MECHANISM OF THE BSFS (BREATH SYNCHRONIZED) SYSTEM</h3>
<p data-path-to-node="5">The BL Series is equipped with the Breath Synchronized-Air Flow System (new BSFS), which delivers airflow that follows the breathing rhythm more closely than ever, becoming a “Highly Synchronized” model.<br />
BSFS ELIMINATES THE FEELING OF BREATHLESSNESS/STUFFINESS<br />
<img loading="lazy" decoding="async" class="size-medium wp-image-191639 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-300x177.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-300x177.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4.jpg 464w" alt="" width="300" height="177" /></p>
<p><b data-path-to-node="2" data-index-in-node="0">THE BSFS MECHANISM HAS EVOLVED INTO “HIGH SYNCHRONIZATION”</b></p>
<p data-path-to-node="3">Using a fan equipped with a breath detection sensor, the device supplies “the necessary and sufficient amount of air” corresponding to the user’s inhalation. Responsiveness to breathing has been improved, and the accuracy of synchronization with the respiratory rhythm has significantly increased.<br />
<img loading="lazy" decoding="async" class="size-medium wp-image-191638 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-300x286.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-300x286.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-768x733.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1.jpg 1024w" alt="" width="300" height="286" /></p>
<h3>COMFORT UP</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">SOLVING MASK DISCOMFORT WITH FLOW THAT FOLLOWS EVERY BREATH</b></p>
<ul>
<li data-path-to-node="4,0,0">Reduces the physical workload for laborers.</li>
<li data-path-to-node="4,1,0">Solves breathing difficulties and stuffiness in high-temperature workplaces.</li>
</ul>
<h3>SAFETY UP</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">PREVENTING INWARD LEAKAGE THROUGH HIGH PROTECTION AND CONSTANT POSITIVE PRESSURE</b></p>
<p data-path-to-node="4,0,0">Breath Synchronization: Protection is guaranteed by the blower linked to breathing.</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class=" wp-image-191633 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-300x227.jpg" sizes="auto, (max-width: 441px) 100vw, 441px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-300x227.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-768x581.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6.jpg 1024w" alt="" width="441" height="334" /></td>
<td width="64"><img loading="lazy" decoding="async" class=" wp-image-191636 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-300x218.png" sizes="auto, (max-width: 508px) 100vw, 508px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-300x218.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-1024x745.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-768x559.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185.png 1407w" alt="" width="508" height="369" /></td>
</tr>
<tr>
<td height="19">
<p data-path-to-node="3,0,0"><b data-path-to-node="3,0,0" data-index-in-node="0">DURING INHALATION:</b> Air inside the mask is normally sucked away, but supplemental airflow prevents negative pressure. (If a gap exists, air blows outward ※1)</p>
<p data-path-to-node="3,0,0">※1: Airflow varies based on facepiece fit.</p>
</td>
<td>
<p data-path-to-node="3,1,0"><b data-path-to-node="3,1,0" data-index-in-node="0">DURING EXHALATION:</b> Since pressure doesn’t drop, airflow is reduced. This conserves the “filter” and “battery.”</p>
<p data-path-to-node="3,1,0">※2: Flow doesn’t stop completely (maintains a small amount for safety).</p>
</td>
</tr>
</tbody>
</table>
<p><b data-path-to-node="2" data-index-in-node="0">PAPR AVOIDS HIGH LEAKAGE RISKS FROM DUST BUILDUP IN LOOSE MASKS</b></p>
<p data-path-to-node="3">FOR CONVENTIONAL DUST MASKS:</p>
<p data-path-to-node="4">As dust builds on the filter, inhalation resistance increases, raising the risk of inward leakage. As dust accumulates, even if the gap remains the same, the leakage rate can double. (See diagram below)</p>
<p><img loading="lazy" decoding="async" class=" wp-image-191632 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-300x195.jpg" sizes="auto, (max-width: 409px) 100vw, 409px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-300x195.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-768x500.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-180x118.jpg 180w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8.jpg 1024w" alt="" width="409" height="266" /></p>
<p><b data-path-to-node="7" data-index-in-node="0">Leakage Measurement Method:</b> A 2.5% gap is created intentionally; NaCl concentration is measured inside/outside the mask with a digital meter.</p>
<h3>ECONOMY UP (ECO)</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">ELIMINATING WASTE THROUGH AN ECO FLOW MECHANISM</b></p>
<p data-path-to-node="4,0,0">Limits “wasteful dust buildup” and reduces filter usage: Minimizes air loss to reduce clogging.<br />
Limits battery usage: Extends runtime by reducing power consumption during low-respiration phases.</p>
<p><b data-path-to-node="2" data-index-in-node="0">BATTERY RUNTIME COMPARISON: NEW VS OLD BSFS</b></p>
<p data-path-to-node="3"><img loading="lazy" decoding="async" class=" wp-image-191631 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/1-300x126.png" sizes="auto, (max-width: 445px) 100vw, 445px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/1-300x126.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-1024x429.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-768x322.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/1.png 1536w" alt="" width="445" height="187" /></p>
<p data-path-to-node="3"><strong>ECO FLOW CREATED BY HIGH SYNCHRONIZATION</strong></p>
<p data-path-to-node="3"><img loading="lazy" decoding="async" class=" wp-image-191630 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/2-300x175.png" sizes="auto, (max-width: 456px) 100vw, 456px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/2-300x175.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-1024x599.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-768x449.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/2.png 1536w" alt="" width="456" height="266" />Image of BSFS flow following actual respiratory waveforms with high precision.</p>
<h2 data-path-to-node="3">KOKEN LIGHTWEIGHT DESIGN: Reducing burden for long shifts</h2>
<p>The “BL Series” optimizes compact sizing and weight equivalent to conventional dust masks. It is highly rated in tunnel construction, asbestos handling, and arc welding.</p>
<p><b data-path-to-node="4" data-index-in-node="0">SEPARATE TYPE</b> Because a direct-mounted battery adds weight to the neck, the separate design reduces perceived weight. This ultra-lightweight design minimizes mask body thickness.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56541" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-122956.png" alt="" width="348" height="302" /></p>
<p><b data-path-to-node="5" data-index-in-node="0">BUILT-IN TYPE</b> Thanks to “High Synchro” BSFS reducing power draw, battery size has been shrunk. This results in a lightweight built-in battery design with minimal burden.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56542" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123026.png" alt="" width="212" height="269" /></p>
<h2>KOKEN SAFETY DESIGN: Internal pressure monitoring to maintain positive pressure</h2>
<p data-path-to-node="3">(Common for BL-321/BL-351/BL-351X/BL-711/BL-700/BL-200/BL-100 series)</p>
<p data-path-to-node="4">Modern worksites require PAPRs that “constantly monitor internal pressure and provide alerts.”<br />
PAPR is most protective under positive pressure; therefore, the moment positive pressure cannot be maintained is the filter replacement time. “Internal monitoring” notifies the user when pressure drops due to weak flow.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56543" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123245.png" alt="" width="243" height="253" /></p>
<p data-path-to-node="7,0,0">■ Positive pressure inside the mask can be maintained through timely/appropriate filter replacement.<br />
■ Clarifies the standard for filter replacement – which is otherwise often vague or based on subjective estimation.<br />
■ Full airflow can be restored through proper battery charging.</p>
<p><b data-path-to-node="2" data-index-in-node="0">NOTIFICATION VIA AIRFLOW</b></p>
<p data-path-to-node="3">(For BL-321 / BL-351 / BL-351X / BL-711 series)</p>
<ul>
<li data-path-to-node="4,0,0">Pressure drop warning via “Continuous Airflow”: ➔ Replace the filter.</li>
<li data-path-to-node="4,1,0">Low battery warning via “Rhythmic Airflow”: ➔ Replace with a charged battery.</li>
</ul>
<p><b data-path-to-node="6" data-index-in-node="0">LED NOTIFICATION</b></p>
<p data-path-to-node="7">(For BL-700 / BL-200 / BL-100 series)</p>
<ul>
<li data-path-to-node="8,0,0">Pressure drop warning via “Flashing LED”: ➔ Replace the filter.</li>
<li data-path-to-node="8,1,0">Low battery warning via “Steady LED”: ➔ Replace with a charged battery.</li>
</ul>
<p><img loading="lazy" decoding="async" class=" wp-image-191629 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/3-300x65.png" sizes="auto, (max-width: 471px) 100vw, 471px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/3-300x65.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-1024x221.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-768x166.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/3.png 1536w" alt="" width="471" height="102" /></p>
<h2>POWERED AIR-PURIFYING PARTICULATE RESPIRATOR (P-PAPR)</h2>
<p>[HALF FACEPIECE TYPE]</p>
<h3>BL-7005 Series</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">A PAPR with a proven record in welding operations</b></p>
<p data-path-to-node="4,0,0"><b data-path-to-node="4,0,0" data-index-in-node="0">Classification:</b> <b data-path-to-node="4,0,0" data-index-in-node="11">STANDARD AIRFLOW TYPE</b></p>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Key Features:</b></p>
<ul>
<li data-path-to-node="6,0,0">High Synchro</li>
<li data-path-to-node="6,1,0">Fit Checker</li>
<li data-path-to-node="6,2,0">Under Chin design</li>
<li data-path-to-node="6,3,0">Silicone material</li>
<li data-path-to-node="6,4,0">Micron filter</li>
<li data-path-to-node="6,5,0">Speaking diaphragm</li>
</ul>
<p>■ Integrated &#8220;Speaking Diaphragm&#8221; for clear communication.<br />
■ Built-in &#8220;Fit Checker&#8221; allows for a quick seal check at any time.<br />
■ &#8220;Auto ON/OFF&#8221; function: Fan automatically operates when breathing starts.<br />
■ Low battery warning during use via &#8220;Airflow Notification.&#8221;<br />
■ Optimized design for compatibility with welding shields and superior downward visibility.</p>
<h3><b data-path-to-node="1" data-index-in-node="0">Sakai Type</b> <b data-path-to-node="1" data-index-in-node="11">BL-7005</b></h3>
<p>Includes battery &amp; charger. Pattern Test Cert TP122</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56574" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_144316-removebg-preview.png" alt="" width="341" height="306" /></p>
<p>Lightest PL2 Model (※) approx 290g<br />
Integrated lightweight battery<br />
※ Cordless PAPR (PL2 models) sold in Japan as of October 2024 (Per company research).</p>
<ul>
<li data-path-to-node="3,0,0">PL2 efficiency</li>
<li data-path-to-node="3,1,0">Class A leakage</li>
<li data-path-to-node="3,2,0">Assigned Protection Factor: 33</li>
</ul>
<p data-path-to-node="4"><b data-path-to-node="4" data-index-in-node="0">Applications:</b></p>
<ul>
<li data-path-to-node="5,0,0">General Dust</li>
<li data-path-to-node="5,1,0">Welding (※)</li>
</ul>
<p><i data-path-to-node="5,1,1,0,0" data-index-in-node="0">(※ For welding tasks requiring a protection factor under 33)<br />
</i><i data-path-to-node="5,1,1,1,0" data-index-in-node="0">(● Also available aluminum-coated version BL-7005AL)</i></p>
<p data-path-to-node="6"><b data-path-to-node="6" data-index-in-node="0">Replacement Filter: </b>Mighty Micron Filter for BL-7005</p>
<p data-path-to-node="8"><b data-path-to-node="8" data-index-in-node="0">Option: </b><b data-path-to-node="9,0,0" data-index-in-node="0">KBC Filter for BL-7005: </b>Activated carbon composite filter.</p>
<h4 data-path-to-node="0"><b data-path-to-node="0" data-index-in-node="0">First use of electrostatic filters for PAPR</b></h4>
<p data-path-to-node="1">The Mighty Micron Filter, with its high collection efficiency and low airflow resistance, further enhances the airflow efficiency of the &#8220;BSFS&#8221; system. This reduction in power consumption has enabled the use of smaller, lighter batteries.</p>
<p data-path-to-node="1"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56575" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-144608.png" alt="" width="226" height="127" /></p>
<h3>EASY MAINTENANCE FOR DUST ACCUMULATION</h3>
<p data-path-to-node="2,0,0">For persistent dust that cannot be removed by wiping, the mask part can be cleaned by rinsing with water.</p>
<p data-path-to-node="2,0,0">(Caution) Always use the maintenance-specific sealing plugs. Do not submerge the unit in water or allow water to enter the internal facepiece. Batteries and filters are not washable. Please follow the individual product manuals.</p>
<table>
<tbody>
<tr>
<th class="xl65" colspan="4" width="256" height="19"><strong>BL-711 SERIES, BL-700 SERIES</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56551" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-132647.png" alt="" width="186" height="145" /></td>
<td>
<p data-path-to-node="2,0,0"><b data-path-to-node="2,0,0" data-index-in-node="0">Mask Part:</b></p>
<p data-path-to-node="2,0,1,0,0">After removing the fan unit and speaker unit (※), the mask can be rinsed with water.<br />
(※ Speaker removal applies only to BL-711 series)</p>
</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56552" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-132703.png" alt="" width="188" height="145" /></td>
<td>
<p data-path-to-node="2,1,0"><b data-path-to-node="2,1,0" data-index-in-node="0">Fan Unit Part:</b></p>
<p data-path-to-node="2,1,1,0,0">Using sealing plugs, the unit can be cleaned with a damp cloth, etc.</p>
</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>BL-321, BL-351X, BL-351 SERIES</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56553" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-132717.png" alt="" width="187" height="143" /></td>
<td>Using sealing plugs, these models can be cleaned by rinsing off external dirt with water.</td>
</tr>
</tbody>
</table>
<h3>Performance Specifications</h3>
<table class="spec-table">
<thead>
<tr>
<th rowspan="2"><strong>Product Name</strong></th>
<th colspan="3"><strong>Classification</strong></th>
<th rowspan="2"><strong>Collection Efficiency</strong></th>
<th rowspan="2"><strong>Weight (incl. battery)</strong></th>
<th rowspan="2"><strong>Facepiece Weight</strong></th>
<th rowspan="2"><strong>Battery Specs</strong></th>
<th rowspan="2"><strong>Nominal Runtime*1</strong></th>
<th rowspan="2"><strong>Actual Runtime*2</strong></th>
<th rowspan="2"><strong>Fan Lifespan</strong></th>
</tr>
<tr>
<th><strong>Fan Type</strong></th>
<th><strong>Leakage Rate</strong></th>
<th><strong>Filter Grade</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td class="product">BL-711H</td>
<td rowspan="4">High Airflow</td>
<td rowspan="4">Class S (≤0.1%)</td>
<td rowspan="4">PL3</td>
<td>99.97% or more</td>
<td colspan="2">≤753g (Avg 723g)</td>
<td class="left" rowspan="4">Rechargeable Li-ion<br />
Rated Voltage: 7.2V<br />
Rated Capacity: 2000mAh<br />
Charge time: approx 3 hours*3<br />
Charge cycles: approx 300*3</td>
<td rowspan="2">Approx 6 hours</td>
<td rowspan="2">Approx 6.5–10 hours</td>
<td rowspan="20">Approx. 2,000 hours*3</td>
</tr>
<tr>
<td class="product">BL-711U</td>
<td>99.99% or more</td>
<td colspan="2">≤753g (Avg 720g)</td>
</tr>
<tr>
<td class="product">BL-700HA</td>
<td>99.97% or more</td>
<td rowspan="2">≤774g</td>
<td rowspan="2">Avg 591g</td>
<td rowspan="2">Approx 7.5 hours</td>
<td rowspan="2">Approx 8–14.5 hours</td>
</tr>
<tr>
<td class="product">BL-700U</td>
<td>99.99% or more</td>
</tr>
<tr>
<td class="product">BL-7005/AL</td>
<td rowspan="3">Standard Airflow</td>
<td rowspan="3">Class A (≤1.0%)</td>
<td>PL2</td>
<td>99.0% or more</td>
<td colspan="2">≤298g (Avg 288g)</td>
<td rowspan="5">Rechargeable Li-ion<br />
Rated Voltage: 3.7V<br />
Rated Capacity: 1100mAh<br />
Charge time: approx 3 hours*3<br />
Charge cycles: approx 300*3</td>
<td>Approx 6.7 hours</td>
<td>Approx 4–9 hours</td>
</tr>
<tr>
<td class="product">BL-1005/AL</td>
<td rowspan="3">PL1</td>
<td>95.0% or more</td>
<td colspan="2">≤278g (Avg 271g)</td>
<td rowspan="2">Approx 8.5 hours</td>
<td rowspan="2">Approx 3.5–11 hours</td>
</tr>
<tr>
<td class="product">BL-1005X/AL</td>
<td>95.0% or more</td>
<td colspan="2">≤285g (Avg 278g)</td>
</tr>
<tr>
<td class="product">BL-321S</td>
<td rowspan="13">High Airflow</td>
<td>Class B (≤5.0%)</td>
<td>95.0% or more</td>
<td colspan="2">≤252g (Avg 244g)</td>
<td>Approx 3.5 hours</td>
<td>Approx 5–9 hours</td>
</tr>
<tr>
<td class="product">BL-321H</td>
<td>Class S (≤0.1%)</td>
<td>PL3</td>
<td>99.97% or more</td>
<td colspan="2">≤265g (Avg 257g)</td>
<td>Approx 3 hours</td>
<td>Approx 3–6 hours</td>
</tr>
<tr>
<td class="product">BL-351S</td>
<td>Class B (≤5.0%)</td>
<td>PL1</td>
<td>95.0% or more</td>
<td colspan="2">Avg 315g</td>
<td rowspan="11">Rechargeable Li-ion<br />
Rated Voltage: 7.2V<br />
Rated Capacity: 2000mAh<br />
Charge time: approx 3 hours*3<br />
Charge cycles: approx 300*3</td>
<td>Approx 10 hours</td>
<td>Approx 13–22 hours</td>
</tr>
<tr>
<td class="product">BL-351H</td>
<td rowspan="3">Class S (≤0.1%)</td>
<td rowspan="3">PL3</td>
<td>99.97% or more</td>
<td colspan="2" rowspan="2">Avg 328g</td>
<td rowspan="3">Approx 9 hours</td>
<td rowspan="3">Approx 8–17 hours</td>
</tr>
<tr>
<td class="product">BL-351U</td>
<td>99.99% or more</td>
</tr>
<tr>
<td class="product">BL-351HX</td>
<td>99.97% or more</td>
<td colspan="2">Avg 333g</td>
</tr>
<tr>
<td class="product">BL-200S</td>
<td>Class B (≤5.0%)</td>
<td>PL1</td>
<td>95.0% or more</td>
<td>≤395g</td>
<td>Avg 219g</td>
<td>Approx 10.5 hours</td>
<td>Approx 12–22 hours</td>
</tr>
<tr>
<td class="product">BL-200H</td>
<td rowspan="2">Class S (≤0.1%)</td>
<td rowspan="2">PL3</td>
<td>99.97% or more</td>
<td rowspan="2">≤409g</td>
<td rowspan="2">Avg 234g</td>
<td rowspan="2">Approx 9.5 hours</td>
<td rowspan="2">Approx 10–18 hours</td>
</tr>
<tr>
<td class="product">BL-200U</td>
<td>99.99% or more</td>
</tr>
<tr>
<td class="product">BL-100S</td>
<td rowspan="2">Class B (≤5.0%)</td>
<td rowspan="2">PL1</td>
<td rowspan="2">95.0% or more</td>
<td rowspan="2">≤383g</td>
<td rowspan="2">Avg 206g</td>
<td rowspan="2">Approx 10 hours</td>
<td rowspan="2">Approx 12–22 hours</td>
</tr>
<tr>
<td class="product">BL-100SC</td>
</tr>
<tr>
<td class="product">BL-100H</td>
<td rowspan="2">Class S (≤0.1%)</td>
<td rowspan="2">PL3</td>
<td>99.97% or more</td>
<td rowspan="2">≤397g</td>
<td rowspan="2">Avg 222g</td>
<td rowspan="2">Approx 9 hours</td>
<td rowspan="2">Approx 10–18 hours</td>
</tr>
<tr>
<td class="product">BL-100U</td>
<td>99.99% or more</td>
</tr>
</tbody>
</table>
<div class="note">
<div>*1 Time maintaining positive pressure inside the facepiece under standard indoor conditions.</div>
<div>*2 Observed duration for maintaining positive pressure in dusty environments, based on actual worker respiratory data during field work.</div>
<div>*3 May vary or be shorter depending on actual usage conditions.</div>
</div>
<h3>Replacement Filters and Optional Accessories</h3>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56559" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_133302-removebg-preview.png" alt="" width="263" height="171" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56560" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_133247-removebg-preview.png" alt="" width="261" height="166" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56558" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_133314-removebg-preview.png" alt="" width="249" height="169" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56554" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-133324.png" alt="" width="228" height="169" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56555" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-133334.png" alt="" width="231" height="166" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56556" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-133347.png" alt="" width="299" height="119" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56557" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-133356.png" alt="" width="261" height="116" /></td>
</tr>
<tr style="height: 14.4pt;">
<td height="19"><strong>Alpha Ring Filter BRD-8U</strong> Screw-on / Twist-lock</td>
<td><strong>Alpha Ring Filter BRD-82</strong> Screw-on / Twist-lock</td>
<td><strong>Alpha Ring Filter BRD-82U</strong> Screw-on / Twist-lock</td>
<td><strong>Alpha Ring Filter BLA-62</strong></td>
<td><strong>Alpha Ring Filter BRD-7</strong></td>
<td><strong>Mighty Micron Filter for BL-7005</strong></td>
<td><strong>Mighty Micron Filter for BL-1005</strong></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<td class="xl65" colspan="2" width="128" height="19">Optional: For Ozone / Organic odor removal (5 pcs/pack)</td>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter wp-image-56561" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-134109.png" alt="" width="366" height="136" /></td>
<td><img loading="lazy" decoding="async" class=" wp-image-191670 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-768x323-1-300x139.png" sizes="auto, (max-width: 319px) 100vw, 319px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-768x323-1-300x139.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-768x323-1-1024x474.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-768x323-1-768x355.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-768x323-1.png 1500w" alt="" width="334" height="155" /></td>
</tr>
<tr>
<td height="19">KBC Filter for BL-7005</td>
<td>KBC Filter for BL-1005</td>
</tr>
</tbody>
</table>
<p data-path-to-node="1,0,0">When performing tasks such as welding or grinding where sparks or spatter are generated, it is mandatory to install the dedicated inhalation port cover (sold separately) on the filter (except for the BL-7005 and BL-1005 series). Note that the BL-700HA/U, BL-200H/U, and BL-100H/U series are not designed for use in environments with sparks or spatter.</p>
<h3 data-path-to-node="0">Key Features:</h3>
<ul>
<li data-path-to-node="1"><b data-path-to-node="1" data-index-in-node="0">High Synchro: </b>Next-generation model improves airflow efficiency and tracks user breathing rhythm more accurately.</li>
<li data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Fit Checker: </b>Easily perform a fit test by simply pulling the lever.</li>
<li data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Under Chin: </b>Unique curved design enhances the airtight seal at the face contact area.</li>
<li data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">Micron: </b>High-performance electrostatic filter. This respirator utilizes Micron filter technology.</li>
<li data-path-to-node="9"><b data-path-to-node="9" data-index-in-node="0">Speaker: </b>Integrated small communication speaker ensures clear dialogue while wearing the mask.</li>
<li data-path-to-node="11"><b data-path-to-node="11" data-index-in-node="0">Special Hard Coating: </b>Improved scratch resistance compared to standard surface hardening methods.</li>
<li data-path-to-node="12,0,0"><b data-path-to-node="14" data-index-in-node="0">Silicone: </b>The facepiece uses medical-grade silicone material for a soft, skin-friendly fit.</li>
<li data-path-to-node="16"><b data-path-to-node="16" data-index-in-node="0">Speaking Diaphragm: </b>Facilitates clear communication and instruction without mask removal.</li>
<li data-path-to-node="18"><b data-path-to-node="18" data-index-in-node="0">Internal Pressure Monitoring: </b>Flashing light alerts the user when positive pressure is lost inside the facepiece.</li>
<li data-path-to-node="20"><b data-path-to-node="20" data-index-in-node="0">HAWC Lip: </b>Full-face models use the HAWC Lip structure for a high-seal &#8220;suction cup effect.&#8221;</li>
<li data-path-to-node="22"><b data-path-to-node="22" data-index-in-node="0">Hardened Eyepiece: </b>The visor surface is treated with a hardening process to resist scratches.</li>
</ul>The post <a href="https://koueitrading.com/global/product/koken-bl-1005-series-p-papr/">Koken BL-1005 Series P-PAPR</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken BL-7005 P-PAPR</title>
		<link>https://koueitrading.com/global/product/koken-bl-7005-p-papr/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Thu, 12 Mar 2020 03:27:36 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=192528</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: BL-7005 P-PAPR: Powered Air-Purifying Particulate Respirator PARTICULATE PAPR and GAS PAPR PAPR: Powered Air-Purifying Respirator. P-PAPR: Particulate PAPR (Used for dust/particles). G-PAPR: Gas PAPR (Used for toxic gases/vapors). Within the PAPR range, there are “Powered Air-Purifying Particulate Respirators (P-PAPR)” for dust hazards and “Powered Air-Purifying Gas Respirators (G-PAPR)” for toxic gas [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-bl-7005-p-papr/">Koken BL-7005 P-PAPR</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: BL-7005</p>
<p>P-PAPR: Powered Air-Purifying Particulate Respirator</p>
<h2>PARTICULATE PAPR and GAS PAPR</h2>
<ul>
<li data-path-to-node="14,0,0">PAPR: Powered Air-Purifying Respirator.</li>
<li data-path-to-node="14,1,0">P-PAPR: Particulate PAPR (Used for dust/particles).</li>
<li data-path-to-node="14,2,0">G-PAPR: Gas PAPR (Used for toxic gases/vapors).</li>
</ul>
<p data-path-to-node="3">Within the PAPR range, there are “Powered Air-Purifying Particulate Respirators (P-PAPR)” for dust hazards and “Powered Air-Purifying Gas Respirators (G-PAPR)” for toxic gas hazards. It is essential to understand the properties, type, and concentration of the hazardous substances before selecting the appropriate mask.</p>
<p data-path-to-node="3">To prevent inhalation of DUST -&gt; Use a Powered Air-Purifying Particulate Respirator (P-PAPR)<br />
To prevent inhalation of TOXIC GAS -&gt; Use a Powered Air-Purifying Gas Respirator (G-PAPR)<br />
To prevent inhalation of MIXED DUST &amp; TOXIC GAS -&gt; Use a Powered Air-Purifying Gas Respirator (G-PAPR) with dust protection function</p>
<h3>Environments where PAPR CANNOT be used</h3>
<p data-path-to-node="9">PAPR must not be used if any of the following conditions apply. Please use respiratory protective equipment suitable for the environment, such as a supplied-air respirator or a self-contained breathing apparatus (SCBA).</p>
<ul>
<li data-path-to-node="10,0,0">Oxygen-deficient environments or those at risk of oxygen deficiency (Oxygen concentration below 18%).</li>
<li data-path-to-node="10,1,0">Cases where the type or concentration of the toxic gas is unknown.</li>
<li data-path-to-node="10,2,0">IDLH environments (Atmospheres Immediately Dangerous to Life or Health).</li>
<li data-path-to-node="10,2,0">Cases where the toxic gas concentration exceeds the permissible limit for the PAPR. ※</li>
<li data-path-to-node="10,3,0">Cases where no filter (canister) is available to remove the specific toxic gas in the environment.</li>
<li data-path-to-node="10,4,0">Cases where a mixture of gases with different properties exists.</li>
<li data-path-to-node="10,5,0">Cases where the environment deviates significantly from normal temperature, humidity, and atmospheric pressure.</li>
</ul>
<p data-path-to-node="11">(※ According to standards based on the Industrial Safety and Health Act, the application range of G-PAPR is 2% (3% for Ammonia))</p>
<h3>SELECTING THE APPROPRIATE PAPR BASED ON HAZARD CONCENTRATION</h3>
<p data-path-to-node="3">Determine the Required Protection Factor, then select a PAPR model with an Assigned Protection Factor higher than that value.</p>
<p data-path-to-node="4,0">Formula: How to calculate the Required Protection Factor<br />
<strong>Required Protection Factor = Ambient concentration of identified hazard / Permissible exposure limit of the hazard</strong></p>
<p>Assigned Protection Factor of P-PAPR</p>
<table>
<thead>
<tr>
<th colspan="2"><strong>Classification</strong></th>
<th colspan="4"><strong>Facepiece Type</strong></th>
</tr>
<tr>
<th><strong>Leakage Rate</strong></th>
<th><strong>Filter Efficiency</strong></th>
<th><strong>Half-face</strong></th>
<th><strong>Full-face</strong></th>
<th><strong>Hood Type</strong></th>
<th><strong>Face shield</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td rowspan="3">Class S</td>
<td>PL3/PS3</td>
<td>50/300</td>
<td>1000</td>
<td>25/1000</td>
<td>25/300</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>—</td>
<td>—</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td rowspan="3">Class A</td>
<td>PL3/PS3</td>
<td>—</td>
<td>—</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>33</td>
<td>90</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>14</td>
<td>19</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td rowspan="3">Class B</td>
<td>PL3/PS3</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>14</td>
<td>19</td>
<td>11</td>
<td>11</td>
</tr>
</tbody>
</table>
<p>Assigned Protection Factor of G-PAPR</p>
<table>
<thead>
<tr>
<th class="header-main" colspan="4"><strong>Facepiece Type</strong></th>
</tr>
<tr>
<th><strong>Half-face</strong></th>
<th><strong>Full-face</strong></th>
<th><strong>Hood Type</strong></th>
<th><strong>Face shield</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>50/300</td>
<td>1000</td>
<td>25/1000</td>
<td>25/300</td>
</tr>
</tbody>
</table>
<p>For “G-PAPR with dust protection function,” please refer to the Assigned Protection Factor of P-PAPR (Class S leakage rate) mentioned above for dust (and similar particulates).</p>
<h2>TASKS WHERE PAPR USE IS MANDATORY BY REGULATION OR DIRECTIVE</h2>
<p><strong>For tasks where PAPR use is mandatory by regulation or directive, please use a PAPR with the designated performance classification.</strong></p>
<h4><strong>1. Tunnel Construction Work</strong></h4>
<p><strong>Regulation:</strong> “Ordinance on Prevention of Pneumoconiosis”<br />
<strong>Scope:</strong> In tunnel construction, at locations involving “mechanical/powered excavation,” “mechanical loading or unloading of ore/rock,” and “shotcreting.”</p>
<p><strong>PAPR Requirements:</strong></p>
<ul>
<li>National test certified product (High airflow type).</li>
<li>Tight-fitting facepiece type where the battery can be removed for use during blasting operations.</li>
</ul>
<h4><strong>2. Asbestos Removal Work</strong></h4>
<p><strong>Regulation:</strong> “Ordinance on Prevention of Health Impairment due to Asbestos”<br />
<strong>Scope</strong>: In asbestos removal tasks, specifically those requiring “Class 1 Asbestos Removal Masks.”<br />
<b data-path-to-node="11,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified tight-fitting or hood types (High airflow, Class S, PL3 or PS3).</p>
<h4 data-path-to-node="12"><b data-path-to-node="12" data-index-in-node="0">3. Handling Nanomaterials</b></h4>
<p data-path-to-node="13,0,0"><b data-path-to-node="13,0,0" data-index-in-node="0">Directive:</b> “Regarding Preventive Measures for Exposure to Nanomaterials”<br />
<b data-path-to-node="13,1,0" data-index-in-node="0">Scope:</b> Manufacturing and handling of nanomaterials. (※)<br />
<b data-path-to-node="13,2,0" data-index-in-node="0">PAPR Requirements:</b></p>
<ul>
<li data-path-to-node="13,2,0">National test certified product (High airflow, PL3 or PS3).</li>
<li data-path-to-node="13,2,1,0,0">Shape limitations based on the projected exposure levels of workers.</li>
</ul>
<p data-path-to-node="13,2,1,1,0">(※) Depending on the work environment, respiratory protective equipment other than PAPR may be used.</p>
<h4 data-path-to-node="14"><b data-path-to-node="14" data-index-in-node="0">4. Handling Indium</b></h4>
<p data-path-to-node="15,0,0"><b data-path-to-node="15,0,0" data-index-in-node="0">Directive:</b> “Regarding Thorough Health Hazard Prevention Measures for Indium/Tin Oxide Handling”<br />
<b data-path-to-node="15,1,0" data-index-in-node="0">Scope:</b> Handling of Indium, Tin Oxide, etc. (※)<br />
<b data-path-to-node="15,2,0" data-index-in-node="0">PAPR Requirements:</b></p>
<ul>
<li data-path-to-node="15,2,0">National test certified product (High airflow, PL3 or PS3).</li>
<li data-path-to-node="15,2,1,0,0">Limitations on shape and leakage rate based on working environment measurement results.</li>
</ul>
<p data-path-to-node="15,2,1,1,0">(※) Depending on environmental results, respiratory protective equipment other than PAPR may be used.</p>
<h4 data-path-to-node="16"><b data-path-to-node="16" data-index-in-node="0">5. Handling Dioxins</b></h4>
<p><b data-path-to-node="17,0,0" data-index-in-node="0">Directive:</b> “Revision of Guidelines for Dioxin Exposure Prevention in Waste Incineration Facilities”<br />
<b data-path-to-node="17,1,0" data-index-in-node="0">Scope:</b> For dioxin-exposure risk tasks classified as “Level 1.” (※)<br />
<b data-path-to-node="17,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified product (High airflow, PL3 or PS3).</p>
<p>(※) RL3 or RS3 dust masks may be used, but PAPR with higher protective performance is recommended.</p>
<h4 data-path-to-node="18"><b data-path-to-node="18" data-index-in-node="0">6. Handling Refractory Ceramic Fibers (RCF)</b></h4>
<p><b data-path-to-node="19,0,0" data-index-in-node="0">Regulation:</b> “Ordinance on Prevention of Hazards due to Specified Chemical Substances”<br />
<b data-path-to-node="19,1,0" data-index-in-node="0">Scope:</b> Insulation or fireproofing work involving the application of RCF to furnaces or boilers; or repair, dismantling, and demolition of such furnaces/boilers.<br />
<b data-path-to-node="19,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified product (PL3 or PS3).</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong>PAPR Standards</strong></th>
<td width="64">Beyond JIS standards, Powered Air-Purifying Respirators must adhere to standards defined under the Industrial Safety and Health Act. These comprehensive standards ensure that products are manufactured under strict safety requirements.</td>
</tr>
</tbody>
</table>
<p>The following table is excerpted from the ‘Standards for Powered Air-Purifying Respirators’</p>
<h3>Types of Powered Air-Purifying Respirators</h3>
<table>
<tbody>
<tr>
<th colspan="2"><strong>Powered Air-Purifying Particulate Respirator (P-PAPR)</strong></th>
</tr>
<tr>
<th rowspan="2"><strong>Powered Air-Purifying Gas Respirator (G-PAPR)</strong></th>
<td>Type with dust protection function</td>
</tr>
<tr>
<td>Type without dust protection function</td>
</tr>
</tbody>
</table>
<p><strong>■ Classification by Shape</strong></p>
<table>
<tbody>
<tr>
<th rowspan="2"><strong>Tight-fitting Facepiece</strong><br />
<span class="sub-item">・Full-face</span><br />
<span class="sub-item">・Half-face</span></th>
<td>Isolation type (with hose)</td>
</tr>
<tr>
<td>Direct connection type</td>
</tr>
<tr>
<th rowspan="2"><strong>Loose-fitting Facepiece</strong><br />
<span class="sub-item">・Hood</span><br />
<span class="sub-item">・Face shield</span></th>
<td>Isolation type (with hose)</td>
</tr>
<tr>
<td>Direct connection type</td>
</tr>
</tbody>
</table>
<p><strong>■ Classification by Performance</strong></p>
<table>
<thead>
<tr>
<th><strong>Airflow Performance Classification</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>Standard airflow type</td>
</tr>
<tr>
<td>High airflow type</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th><strong>Leakage Rate Performance Classification (P-PAPR)</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>Class B</td>
</tr>
<tr>
<td>Class A</td>
</tr>
<tr>
<td>Class S</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th colspan="2"><strong>Filter Material Performance Classification<br />
(P-PAPR and G-PAPR with dust function)</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td width="50%">PS1</td>
<td width="50%">PL1</td>
</tr>
<tr>
<td>PS2</td>
<td>PL2</td>
</tr>
<tr>
<td>PS3</td>
<td>PL3</td>
</tr>
</tbody>
</table>
<h3>Performance Testing for Powered Air-Purifying Respirators</h3>
<h4><strong>■ Particle Collection Efficiency Test</strong></h4>
<p>(Applies only to P-PAPR and G-PAPR with dust protection)</p>
<table>
<tbody>
<tr>
<th class="header-bg col-label" rowspan="3"><strong>Test Particle</strong></th>
<th class="header-bg col-sub"><strong>Type</strong></th>
<td class="align-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="align-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="header-bg"><strong>Particle Size</strong></th>
<td colspan="2">0.06μm ~ 0.1μm</td>
<td colspan="2">0.15μm ~ 0.25μm</td>
</tr>
<tr>
<th class="header-bg"><strong>Concentration</strong></th>
<td colspan="2">50mg/m³ or less</td>
<td colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="header-bg" rowspan="2"><strong>Test Flow Rate</strong></th>
<th class="header-bg"><strong>Standard Flow</strong></th>
<td colspan="4">104 L/min</td>
</tr>
<tr>
<th class="header-bg"><strong>High Flow</strong></th>
<td colspan="4">138 L/min</td>
</tr>
<tr>
<th class="header-bg align-left" colspan="2" rowspan="4"><strong>Collection Efficiency<br />
(Continuous measurement; must meet values in the right column)</strong></th>
<td colspan="2">For NaCl, loaded up to 200mg</td>
<td colspan="2">For DOP, loaded up to 400mg</td>
</tr>
<tr>
<td class="col-val">PS1</td>
<td class="col-res">95.0% or more</td>
<td class="col-val">PL1</td>
<td class="col-res">95.0% or more</td>
</tr>
<tr>
<td>PS2</td>
<td>99.0% or more</td>
<td>PL2</td>
<td>99.0% or more</td>
</tr>
<tr>
<td>PS3</td>
<td>99.97% or more</td>
<td>PL3</td>
<td>99.97% or more</td>
</tr>
</tbody>
</table>
<h4><strong>■ Canister Testing</strong></h4>
<p>(Applies only to G-PAPR)</p>
<table>
<tbody>
<tr>
<th><strong>Airtightness</strong></th>
<td class="align-left" colspan="4">No air leakage at 1470 Pa pressure</td>
</tr>
<tr>
<th rowspan="5"><strong>Decontamination Capacity<br />
(Time until breakthrough at specified concentration must be ≥ the right column)</strong></th>
<th><strong>Type</strong></th>
<th><strong>Test Gas</strong></th>
<th><strong>Breakthrough Concentration</strong></th>
<th><strong>Duration</strong></th>
</tr>
<tr>
<td>Halogen gas</td>
<td>Chlorine (0.02%)</td>
<td>1 ppm</td>
<td>40 mins or more</td>
</tr>
<tr>
<td>Organic gas</td>
<td>Cyclohexane (0.03%)</td>
<td>5 ppm</td>
<td>50 mins or more</td>
</tr>
<tr>
<td>Ammonia</td>
<td>Ammonia (0.1%)</td>
<td>50 ppm</td>
<td>40 mins or more</td>
</tr>
<tr>
<td>SO₂ gas</td>
<td>Sulfur dioxide (0.03%)</td>
<td>5 ppm</td>
<td>35 mins or more</td>
</tr>
<tr>
<th><strong>Leakage Concentration</strong></th>
<td class="align-left" colspan="4">At maximum flow rate, time to reach breakthrough must be ≥ 3 minutes.</td>
</tr>
</tbody>
</table>
<h4><strong>■ Inward Leakage Rate Test</strong></h4>
<table>
<colgroup>
<col />
<col />
<col />
<col /></colgroup>
<tbody>
<tr>
<th rowspan="3"><strong>Test Particle</strong></th>
<th><strong>Type</strong></th>
<td colspan="4">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<th><strong>Particle Size</strong></th>
<td colspan="4">0.06μm ~ 0.2μm</td>
</tr>
<tr>
<th><strong>Concentration</strong></th>
<td colspan="4">18mg/m³ or less</td>
</tr>
<tr>
<th rowspan="4"><strong>Simulated Breathing</strong></th>
<th><strong>Type</strong></th>
<td colspan="2">Standard Flow</td>
<td colspan="2">High Flow</td>
</tr>
<tr>
<th><strong>Waveform</strong></th>
<td colspan="4">Sine wave</td>
</tr>
<tr>
<th><strong>Ventilation Volume</strong></th>
<td colspan="2">1.5 ± 0.075 L/stroke</td>
<td colspan="2">1.6 ± 0.08 L/stroke</td>
</tr>
<tr>
<th><strong>Frequency</strong></th>
<td colspan="2">20 times/min</td>
<td colspan="2">25 times/min</td>
</tr>
<tr>
<th colspan="2" rowspan="4"><strong>Leakage Rate<br />
(2-minute continuous measurement; max value must meet the right column)</strong></th>
<td rowspan="3">P-PAPR</td>
<td>Class B</td>
<td colspan="2">5.0% or less</td>
</tr>
<tr>
<td>Class A</td>
<td colspan="2">1.0% or less</td>
</tr>
<tr>
<td>Class S</td>
<td colspan="2">0.1% or less</td>
</tr>
<tr>
<td>G-PAPR</td>
<td colspan="3">0.1% or less</td>
</tr>
<tr>
<th colspan="2" rowspan="4"><strong>Headform Movement<br />
(Calculate leakage rate for each item)</strong></th>
<th colspan="3"><strong>Position and Range</strong></th>
<th><strong>Frequency</strong></th>
</tr>
<tr>
<td rowspan="2">Head</td>
<td colspan="2">Front/Back 30 degrees</td>
<td>17 times/min</td>
</tr>
<tr>
<td colspan="2">Left/Right rotation 50 degrees</td>
<td>11 times/min</td>
</tr>
<tr>
<td>Arms</td>
<td colspan="2">Raising 10 ~ 130 degrees</td>
<td>7 times/min</td>
</tr>
</tbody>
</table>
<h4><strong>■ Other Tests</strong></h4>
<table>
<tbody>
<tr>
<th><strong>Internal Pressure<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">Under simulated breathing identical to the leakage test:<br />
0 Pa &lt; Internal Mask Pressure &lt; 400 Pa</td>
</tr>
<tr>
<th rowspan="2"><strong>Minimum Required Flow<br />
(Loose-fit only)</strong></th>
<td class="align-center">Standard Flow</td>
<td class="align-center">104 L/min or more</td>
</tr>
<tr>
<td class="align-center">High Flow</td>
<td class="align-center">138 L/min or more</td>
</tr>
<tr>
<th><strong>Inhalation Resistance<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">160 Pa or less<br />
(40 L/min flow rate, fan OFF)</td>
</tr>
<tr>
<th><strong>Exhalation Resistance<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">80 Pa or less<br />
(40 L/min flow rate, fan OFF)</td>
</tr>
<tr>
<th><strong>Exhalation Valve Airtightness<br />
(Tight-fitting only)</strong></th>
<td class="content-cell" colspan="2">・Internal pressure must drop immediately when air is sucked.<br />
・Time for pressure to return to normal must be ≥ 15 seconds.</td>
</tr>
<tr>
<th><strong>CO2 Concentration Increase<br />
(Tight-fitting only)</strong></th>
<td class="content-cell" colspan="2">With fan OFF, headform breathes CO2 air. Difference between wearing and not wearing mask must be &lt; 2.0%.</td>
</tr>
<tr>
<th><strong>Noise Level</strong></th>
<td class="align-center" colspan="2">Noise at the headform ear area must be below 80 dB (both sides).</td>
</tr>
<tr>
<th rowspan="4"><strong>Flow Rate<br />
(G-PAPR only)</strong></th>
<td>Max set average flow</td>
<td class="content-cell">Average must be ≤ the decontamination test flow rate.</td>
</tr>
<tr>
<td>Maximum flow</td>
<td class="content-cell">Maximum must be ≤ the flow rate set by the manufacturer.</td>
</tr>
<tr>
<th><strong>Tight-fitting type</strong></th>
<th><strong>Loose-fitting type</strong></th>
</tr>
<tr>
<td class="content-cell">Measure resistance with fan OFF/ON at 20~170 L/min to calculate flow per minute.</td>
<td class="content-cell">With fan ON, draw air for 5 mins to maintain normal pressure in chamber, then measure flow.</td>
</tr>
</tbody>
</table>
<h2>PAPR USE IS ENCOURAGED IN THE 10TH COMPREHENSIVE DUST HAZARD COUNTERMEASURES</h2>
<p><strong>To reduce pneumoconiosis, dust prevention measures must be strengthened.</strong></p>
<p>The “10th Comprehensive Countermeasures for Preventing Dust Hazards” demands the correct use of effective respiratory protection against dust exposure across all industries. PAPR is highlighted as a “more effective preventive measure for health impairment,” and its adoption is highly encouraged.<br />
The use of PAPR is more effective in preventing health impairment compared to standard dust masks due to its higher protection factor and reduced physical strain on the wearer.<br />
(Partial excerpt from the 10th Comprehensive Countermeasures)</p>
<p>Furthermore, due to high performance, PAPR is mandatory for specific tasks, but its use is also recommended for tasks outside the mandatory categories.<br />
While PAPR is mandatory for specific operations under the Dust Rules, its high performance makes it desirable for other tasks; thus, guidance and inspections encourage businesses to adopt PAPR for their workers.<br />
(Partial excerpt from the 10th Comprehensive Countermeasures)</p>
<h2>KOKEN BL SERIES BREATH-RESPONSIVE PAPR</h2>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Achieving “High Safety” and “Comfortable Fit” as expected</b></p>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">THE EVOLUTION OF THE BL SERIES</b></p>
<p data-path-to-node="6">The BL Series continues to evolve into the PAPR model that helps perfect safety and health management in every field, aligning with occupational health trends and market expansion.</p>
<p data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">CORE DEVELOPMENT FOCUS</b></p>
<ul>
<li data-path-to-node="8,0,0"><b data-path-to-node="8,0,0" data-index-in-node="0">“Safety”:</b> Improving the protection capability as a respirator.</li>
<li data-path-to-node="8,1,0"><b data-path-to-node="8,1,0" data-index-in-node="0">“Flow Technology”:</b> Minimizing waste and improving efficiency.</li>
<li data-path-to-node="8,2,0"><b data-path-to-node="8,2,0" data-index-in-node="0">“Lightweight Design”:</b> Reducing the burden on the worker.</li>
</ul>
<h2>KOKEN FLOW TECHNOLOGY: New BSFS air flow highly synchronized with breathing</h2>
<h3>THE MECHANISM OF THE BSFS (BREATH SYNCHRONIZED) SYSTEM</h3>
<p data-path-to-node="5">The BL Series is equipped with the Breath Synchronized-Air Flow System (new BSFS), which delivers airflow that follows the breathing rhythm more closely than ever, becoming a “Highly Synchronized” model.<br />
BSFS ELIMINATES THE FEELING OF BREATHLESSNESS/STUFFINESS<br />
<img loading="lazy" decoding="async" class="size-medium wp-image-191639 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-300x177.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-300x177.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4.jpg 464w" alt="" width="300" height="177" /></p>
<p><b data-path-to-node="2" data-index-in-node="0">THE BSFS MECHANISM HAS EVOLVED INTO “HIGH SYNCHRONIZATION”</b></p>
<p data-path-to-node="3">Using a fan equipped with a breath detection sensor, the device supplies “the necessary and sufficient amount of air” corresponding to the user’s inhalation. Responsiveness to breathing has been improved, and the accuracy of synchronization with the respiratory rhythm has significantly increased.<br />
<img loading="lazy" decoding="async" class="size-medium wp-image-191638 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-300x286.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-300x286.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-768x733.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1.jpg 1024w" alt="" width="300" height="286" /></p>
<h3>COMFORT UP</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">SOLVING MASK DISCOMFORT WITH FLOW THAT FOLLOWS EVERY BREATH</b></p>
<ul>
<li data-path-to-node="4,0,0">Reduces the physical workload for laborers.</li>
<li data-path-to-node="4,1,0">Solves breathing difficulties and stuffiness in high-temperature workplaces.</li>
</ul>
<h3>SAFETY UP</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">PREVENTING INWARD LEAKAGE THROUGH HIGH PROTECTION AND CONSTANT POSITIVE PRESSURE</b></p>
<p data-path-to-node="4,0,0">Breath Synchronization: Protection is guaranteed by the blower linked to breathing.</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class=" wp-image-191633 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-300x227.jpg" sizes="auto, (max-width: 441px) 100vw, 441px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-300x227.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-768x581.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6.jpg 1024w" alt="" width="450" height="340" /></td>
<td width="64"><img loading="lazy" decoding="async" class=" wp-image-191636 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-300x218.png" sizes="auto, (max-width: 508px) 100vw, 508px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-300x218.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-1024x745.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-768x559.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185.png 1407w" alt="" width="460" height="334" /></td>
</tr>
<tr>
<td height="19">
<p data-path-to-node="3,0,0"><b data-path-to-node="3,0,0" data-index-in-node="0">DURING INHALATION:</b> Air inside the mask is normally sucked away, but supplemental airflow prevents negative pressure. (If a gap exists, air blows outward ※1)</p>
<p data-path-to-node="3,0,0">※1: Airflow varies based on facepiece fit.</p>
</td>
<td>
<p data-path-to-node="3,1,0"><b data-path-to-node="3,1,0" data-index-in-node="0">DURING EXHALATION:</b> Since pressure doesn’t drop, airflow is reduced. This conserves the “filter” and “battery.”</p>
<p data-path-to-node="3,1,0">※2: Flow doesn’t stop completely (maintains a small amount for safety).</p>
</td>
</tr>
</tbody>
</table>
<p><b data-path-to-node="2" data-index-in-node="0">PAPR AVOIDS HIGH LEAKAGE RISKS FROM DUST BUILDUP IN LOOSE MASKS</b></p>
<p data-path-to-node="3">FOR CONVENTIONAL DUST MASKS:</p>
<p data-path-to-node="4">As dust builds on the filter, inhalation resistance increases, raising the risk of inward leakage. As dust accumulates, even if the gap remains the same, the leakage rate can double. (See diagram below)</p>
<p><img loading="lazy" decoding="async" class=" wp-image-191632 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-300x195.jpg" sizes="auto, (max-width: 409px) 100vw, 409px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-300x195.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-768x500.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-180x118.jpg 180w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8.jpg 1024w" alt="" width="409" height="266" /></p>
<p><b data-path-to-node="7" data-index-in-node="0">Leakage Measurement Method:</b> A 2.5% gap is created intentionally; NaCl concentration is measured inside/outside the mask with a digital meter.</p>
<h3>ECONOMY UP (ECO)</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">ELIMINATING WASTE THROUGH AN ECO FLOW MECHANISM</b></p>
<p data-path-to-node="4,0,0">Limits “wasteful dust buildup” and reduces filter usage: Minimizes air loss to reduce clogging.<br />
Limits battery usage: Extends runtime by reducing power consumption during low-respiration phases.</p>
<p><b data-path-to-node="2" data-index-in-node="0">BATTERY RUNTIME COMPARISON: NEW VS OLD BSFS</b></p>
<p data-path-to-node="3"><img loading="lazy" decoding="async" class=" wp-image-191631 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/1-300x126.png" sizes="auto, (max-width: 445px) 100vw, 445px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/1-300x126.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-1024x429.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-768x322.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/1.png 1536w" alt="" width="445" height="187" /></p>
<p data-path-to-node="3"><strong>ECO FLOW CREATED BY HIGH SYNCHRONIZATION</strong></p>
<p data-path-to-node="3"><img loading="lazy" decoding="async" class=" wp-image-191630 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/2-300x175.png" sizes="auto, (max-width: 456px) 100vw, 456px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/2-300x175.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-1024x599.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-768x449.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/2.png 1536w" alt="" width="456" height="266" />Image of BSFS flow following actual respiratory waveforms with high precision.</p>
<h2 data-path-to-node="3">KOKEN LIGHTWEIGHT DESIGN: Reducing burden for long shifts</h2>
<p>The “BL Series” optimizes compact sizing and weight equivalent to conventional dust masks. It is highly rated in tunnel construction, asbestos handling, and arc welding.</p>
<p><b data-path-to-node="4" data-index-in-node="0">SEPARATE TYPE</b> Because a direct-mounted battery adds weight to the neck, the separate design reduces perceived weight. This ultra-lightweight design minimizes mask body thickness.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56541" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-122956.png" alt="" width="348" height="302" /></p>
<p><b data-path-to-node="5" data-index-in-node="0">BUILT-IN TYPE</b> Thanks to “High Synchro” BSFS reducing power draw, battery size has been shrunk. This results in a lightweight built-in battery design with minimal burden.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56542" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123026.png" alt="" width="212" height="269" /></p>
<h2>KOKEN SAFETY DESIGN: Internal pressure monitoring to maintain positive pressure</h2>
<p data-path-to-node="3">(Common for BL-321/BL-351/BL-351X/BL-711/BL-700/BL-200/BL-100 series)</p>
<p data-path-to-node="4">Modern worksites require PAPRs that “constantly monitor internal pressure and provide alerts.”<br />
PAPR is most protective under positive pressure; therefore, the moment positive pressure cannot be maintained is the filter replacement time. “Internal monitoring” notifies the user when pressure drops due to weak flow.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56543" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123245.png" alt="" width="243" height="253" /></p>
<p data-path-to-node="7,0,0">■ Positive pressure inside the mask can be maintained through timely/appropriate filter replacement.<br />
■ Clarifies the standard for filter replacement – which is otherwise often vague or based on subjective estimation.<br />
■ Full airflow can be restored through proper battery charging.</p>
<p><b data-path-to-node="2" data-index-in-node="0">NOTIFICATION VIA AIRFLOW</b></p>
<p data-path-to-node="3">(For BL-321 / BL-351 / BL-351X / BL-711 series)</p>
<ul>
<li data-path-to-node="4,0,0">Pressure drop warning via “Continuous Airflow”: ➔ Replace the filter.</li>
<li data-path-to-node="4,1,0">Low battery warning via “Rhythmic Airflow”: ➔ Replace with a charged battery.</li>
</ul>
<p><b data-path-to-node="6" data-index-in-node="0">LED NOTIFICATION</b></p>
<p data-path-to-node="7">(For BL-700 / BL-200 / BL-100 series)</p>
<ul>
<li data-path-to-node="8,0,0">Pressure drop warning via “Flashing LED”: ➔ Replace the filter.</li>
<li data-path-to-node="8,1,0">Low battery warning via “Steady LED”: ➔ Replace with a charged battery.</li>
</ul>
<p><img loading="lazy" decoding="async" class=" wp-image-191629 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/3-300x65.png" sizes="auto, (max-width: 471px) 100vw, 471px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/3-300x65.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-1024x221.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-768x166.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/3.png 1536w" alt="" width="471" height="102" /></p>
<h2>POWERED AIR-PURIFYING PARTICULATE RESPIRATOR (P-PAPR)</h2>
<p>[HALF FACEPIECE TYPE]</p>
<h3 data-path-to-node="2"><b data-path-to-node="2" data-index-in-node="0">BL-7005 Series</b></h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">A PAPR with a proven record in welding operations</b></p>
<p data-path-to-node="4,0,0"><b data-path-to-node="4,0,0" data-index-in-node="0">Classification:</b> <b data-path-to-node="4,0,0" data-index-in-node="11">STANDARD AIRFLOW TYPE</b></p>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Key Features:</b></p>
<ul>
<li data-path-to-node="6,0,0">High Synchro</li>
<li data-path-to-node="6,1,0">Fit Checker</li>
<li data-path-to-node="6,2,0">Under Chin design</li>
<li data-path-to-node="6,3,0">Silicone material</li>
<li data-path-to-node="6,4,0">Micron filter</li>
<li data-path-to-node="6,5,0">Speaking diaphragm</li>
</ul>
<p>■ Integrated &#8220;Speaking Diaphragm&#8221; for clear communication.<br />
■ Built-in &#8220;Fit Checker&#8221; allows for a quick seal check at any time.<br />
■ &#8220;Auto ON/OFF&#8221; function: Fan automatically operates when breathing starts.<br />
■ Low battery warning during use via &#8220;Airflow Notification.&#8221;<br />
■ Optimized design for compatibility with welding shields and superior downward visibility.</p>
<h3><b data-path-to-node="1" data-index-in-node="0">Sakai Type</b> <b data-path-to-node="1" data-index-in-node="11">BL-7005</b></h3>
<p>Includes battery &amp; charger. Pattern Test Cert TP122<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56574" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_144316-removebg-preview.png" alt="" width="341" height="306" /><br />
Lightest PL2 Model (※) approx 290g<br />
Integrated lightweight battery<br />
※ Cordless PAPR (PL2 models) sold in Japan as of October 2024 (Per company research).</p>
<ul>
<li data-path-to-node="3,0,0">PL2 efficiency</li>
<li data-path-to-node="3,1,0">Class A leakage</li>
<li data-path-to-node="3,2,0">Assigned Protection Factor: 33</li>
</ul>
<p data-path-to-node="4"><b data-path-to-node="4" data-index-in-node="0">Applications:</b></p>
<ul>
<li data-path-to-node="5,0,0">General Dust</li>
<li data-path-to-node="5,1,0">Welding (※)</li>
</ul>
<p><i data-path-to-node="5,1,1,0,0" data-index-in-node="0">(※ For welding tasks requiring a protection factor under 33)<br />
</i><i data-path-to-node="5,1,1,1,0" data-index-in-node="0">(● Aluminum-coated version BL-7005AL also available)</i></p>
<p data-path-to-node="6"><b data-path-to-node="6" data-index-in-node="0">Replacement Filter: </b>Mighty Micron Filter for BL-7005</p>
<p data-path-to-node="8"><b data-path-to-node="8" data-index-in-node="0">Option: </b><b data-path-to-node="9,0,0" data-index-in-node="0">KBC Filter for BL-7005: </b>Activated carbon composite filter.</p>
<h4 data-path-to-node="0"><b data-path-to-node="0" data-index-in-node="0">First use of electrostatic filters for PAPR</b></h4>
<p data-path-to-node="1">The Mighty Micron Filter, with its high collection efficiency and low airflow resistance, further enhances the airflow efficiency of the &#8220;BSFS&#8221; system. This reduction in power consumption has enabled the use of smaller, lighter batteries.</p>
<p data-path-to-node="1"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56575" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-144608.png" alt="" width="226" height="127" /></p>
<h3>EASY MAINTENANCE FOR DUST ACCUMULATION</h3>
<p data-path-to-node="2,0,0">For persistent dust that cannot be removed by wiping, the mask part can be cleaned by rinsing with water.</p>
<p data-path-to-node="2,0,0">(Caution) Always use the maintenance-specific sealing plugs. Do not submerge the unit in water or allow water to enter the internal facepiece. Batteries and filters are not washable. Please follow the individual product manuals.</p>
<table>
<tbody>
<tr>
<th class="xl65" colspan="4" width="256" height="19"><strong>BL-711 SERIES, BL-700 SERIES</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56551" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-132647.png" alt="" width="186" height="145" /></td>
<td>
<p data-path-to-node="2,0,0"><b data-path-to-node="2,0,0" data-index-in-node="0">Mask Part:</b></p>
<p data-path-to-node="2,0,1,0,0">After removing the fan unit and speaker unit (※), the mask can be rinsed with water.<br />
(※ Speaker removal applies only to BL-711 series)</p>
</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56552" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-132703.png" alt="" width="188" height="145" /></td>
<td>
<p data-path-to-node="2,1,0"><b data-path-to-node="2,1,0" data-index-in-node="0">Fan Unit Part:</b></p>
<p data-path-to-node="2,1,1,0,0">Using sealing plugs, the unit can be cleaned with a damp cloth, etc.</p>
</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>BL-321, BL-351X, BL-351 SERIES</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56553" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-132717.png" alt="" width="187" height="143" /></td>
<td>Using sealing plugs, these models can be cleaned by rinsing off external dirt with water.</td>
</tr>
</tbody>
</table>
<h3>Performance Specifications</h3>
<table class="spec-table">
<thead>
<tr>
<th rowspan="2"><strong>Product Name</strong></th>
<th colspan="3"><strong>Classification</strong></th>
<th rowspan="2"><strong>Collection Efficiency</strong></th>
<th rowspan="2"><strong>Weight (incl. battery)</strong></th>
<th rowspan="2"><strong>Facepiece Weight</strong></th>
<th rowspan="2"><strong>Battery Specs</strong></th>
<th rowspan="2"><strong>Nominal Runtime*1</strong></th>
<th rowspan="2"><strong>Actual Runtime*2</strong></th>
<th rowspan="2"><strong>Fan Lifespan</strong></th>
</tr>
<tr>
<th><strong>Fan Type</strong></th>
<th><strong>Leakage Rate</strong></th>
<th><strong>Filter Grade</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td class="product">BL-711H</td>
<td rowspan="4">High Airflow</td>
<td rowspan="4">Class S (≤0.1%)</td>
<td rowspan="4">PL3</td>
<td>99.97% or more</td>
<td colspan="2">≤753g (Avg 723g)</td>
<td class="left" rowspan="4">Li-ion Rechargeable<br />
Voltage: 7.2V<br />
Capacity: 2000mAh<br />
Charging: ~3 hours*3<br />
Cycles: ~300 times*3</td>
<td rowspan="2">Approx. 6 hours</td>
<td rowspan="2">Approx. 6.5–10 hours</td>
<td rowspan="20">Approx. 2,000 hours*3</td>
</tr>
<tr>
<td class="product">BL-711U</td>
<td>99.99% or more</td>
<td colspan="2">≤753g (Avg 720g)</td>
</tr>
<tr>
<td class="product">BL-700HA</td>
<td>99.97% or more</td>
<td rowspan="2">≤774g</td>
<td rowspan="2">Avg 591g</td>
<td rowspan="2">Approx. 7.5 hours</td>
<td rowspan="2">Approx. 8–14.5 hours</td>
</tr>
<tr>
<td class="product">BL-700U</td>
<td>99.99% or more</td>
</tr>
<tr>
<td class="product">BL-7005/AL</td>
<td rowspan="3">Standard Airflow</td>
<td rowspan="3">Class A (≤1.0%)</td>
<td>PL2</td>
<td>99.0% or more</td>
<td colspan="2">≤298g (Avg 288g)</td>
<td rowspan="5">Li-ion Rechargeable<br />
Voltage: 3.7V<br />
Capacity: 1100mAh<br />
Charging: ~3 hours*3<br />
Cycles: ~300 times*3</td>
<td>Approx. 6.7 hours</td>
<td>Approx. 4–9 hours</td>
</tr>
<tr>
<td class="product">BL-1005/AL</td>
<td rowspan="3">PL1</td>
<td>95.0% or more</td>
<td colspan="2">≤278g (Avg 271g)</td>
<td rowspan="2">Approx. 8.5 hours</td>
<td rowspan="2">Approx. 3.5–11 hours</td>
</tr>
<tr>
<td class="product">BL-1005X/AL</td>
<td>95.0% or more</td>
<td colspan="2">≤285g (Avg 278g)</td>
</tr>
<tr>
<td class="product">BL-321S</td>
<td rowspan="13">High Airflow</td>
<td>Class B (≤5.0%)</td>
<td>95.0% or more</td>
<td colspan="2">≤252g (Avg 244g)</td>
<td>Approx. 3.5 hours</td>
<td>Approx. 5–9 hours</td>
</tr>
<tr>
<td class="product">BL-321H</td>
<td>Class S (≤0.1%)</td>
<td>PL3</td>
<td>99.97% or more</td>
<td colspan="2">≤265g (Avg 257g)</td>
<td>Approx. 3 hours</td>
<td>Approx. 3–6 hours</td>
</tr>
<tr>
<td class="product">BL-351S</td>
<td>Class B (≤5.0%)</td>
<td>PL1</td>
<td>95.0% or more</td>
<td colspan="2">Avg 315g</td>
<td rowspan="11">Li-ion Rechargeable<br />
Voltage: 7.2V<br />
Capacity: 2000mAh<br />
Charging: ~3 hours*3<br />
Cycles: ~300 times*3</td>
<td>Approx. 10 hours</td>
<td>Approx. 13–22 hours</td>
</tr>
<tr>
<td class="product">BL-351H</td>
<td rowspan="3">Class S (≤0.1%)</td>
<td rowspan="3">PL3</td>
<td>99.97% or more</td>
<td colspan="2" rowspan="2">Avg 328g</td>
<td rowspan="3">Approx. 9 hours</td>
<td rowspan="3">Approx. 8–17 hours</td>
</tr>
<tr>
<td class="product">BL-351U</td>
<td>99.99% or more</td>
</tr>
<tr>
<td class="product">BL-351HX</td>
<td>99.97% or more</td>
<td colspan="2">Avg 333g</td>
</tr>
<tr>
<td class="product">BL-200S</td>
<td>Class B (≤5.0%)</td>
<td>PL1</td>
<td>95.0% or more</td>
<td>≤395g</td>
<td>Avg 219g</td>
<td>Approx. 10.5 hours</td>
<td>Approx. 12–22 hours</td>
</tr>
<tr>
<td class="product">BL-200H</td>
<td rowspan="2">Class S (≤0.1%)</td>
<td rowspan="2">PL3</td>
<td>99.97% or more</td>
<td rowspan="2">≤409g</td>
<td rowspan="2">Avg 234g</td>
<td rowspan="2">Approx. 9.5 hours</td>
<td rowspan="2">Approx. 10–18 hours</td>
</tr>
<tr>
<td class="product">BL-200U</td>
<td>99.99% or more</td>
</tr>
<tr>
<td class="product">BL-100S</td>
<td rowspan="2">Class B (≤5.0%)</td>
<td rowspan="2">PL1</td>
<td rowspan="2">95.0% or more</td>
<td rowspan="2">≤383g</td>
<td rowspan="2">Avg 206g</td>
<td rowspan="2">Approx. 10 hours</td>
<td rowspan="2">Approx. 12–22 hours</td>
</tr>
<tr>
<td class="product">BL-100SC</td>
</tr>
<tr>
<td class="product">BL-100H</td>
<td rowspan="2">Class S (≤0.1%)</td>
<td rowspan="2">PL3</td>
<td>99.97% or more</td>
<td rowspan="2">≤397g</td>
<td rowspan="2">Avg 222g</td>
<td rowspan="2">Approx. 9 hours</td>
<td rowspan="2">Approx. 10–18 hours</td>
</tr>
<tr>
<td class="product">BL-100U</td>
<td>99.99% or more</td>
</tr>
</tbody>
</table>
<div class="note">
<div>*1 Calculated duration for maintaining positive pressure inside the facepiece under standard indoor conditions.</div>
<div>*2 Observed duration for maintaining positive pressure in dusty environments, based on actual worker respiratory data during field work.</div>
<div>*3 May vary or be shorter depending on actual usage conditions.</div>
</div>
<h3>Replacement Filters and Optional Accessories</h3>
<table>
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56559" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_133302-removebg-preview.png" alt="" width="263" height="171" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56560" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_133247-removebg-preview.png" alt="" width="261" height="166" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56558" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_133314-removebg-preview.png" alt="" width="249" height="169" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56554" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-133324.png" alt="" width="228" height="169" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56555" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-133334.png" alt="" width="231" height="166" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56556" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-133347.png" alt="" width="299" height="119" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56557" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-133356.png" alt="" width="261" height="116" /></td>
</tr>
<tr>
<td height="19"><strong>Alpha Ring Filter BRD-8U</strong><br />
Screw-on / Twist-lock</td>
<td><strong>Alpha Ring Filter BRD-82</strong><br />
Screw-on / Twist-lock</td>
<td><strong>Alpha Ring Filter BRD-82U</strong><br />
Screw-on / Twist-lock</td>
<td><strong>Alpha Ring Filter BLA-62</strong></td>
<td><strong>Alpha Ring Filter BRD-7</strong></td>
<td><strong>Mighty Micron Filter For BL-7005</strong></td>
<td><strong>Mighty Micron Filter For BL-1005</strong></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<td class="xl65" colspan="2" width="128" height="19">Optional: For Ozone / Organic odor removal (5 pcs/pack)</td>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter wp-image-56561" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-134109.png" alt="" width="366" height="136" /></td>
<td><img loading="lazy" decoding="async" class=" wp-image-191670 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-768x323-1-300x139.png" sizes="auto, (max-width: 319px) 100vw, 319px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-768x323-1-300x139.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-768x323-1-1024x474.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-768x323-1-768x355.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-768x323-1.png 1500w" alt="" width="334" height="155" /></td>
</tr>
<tr>
<td height="19">KBC Filter For BL-7005</td>
<td>KBC Filter For BL-1005</td>
</tr>
</tbody>
</table>
<p data-path-to-node="1,0,0">When performing tasks such as welding or grinding that generate sparks or spatter, it is mandatory to install the dedicated inhalation port cover (sold separately) on the filter (except for the BL-7005 and BL-1005 series). Note that the BL-700HA/U, BL-200H/U, and BL-100H/U series are not designed for use in environments with sparks or spatter.</p>
<h3 data-path-to-node="0">Key Features:</h3>
<ul>
<li data-path-to-node="1"><b data-path-to-node="1" data-index-in-node="0">High Synchro: </b>Next-generation model improves airflow efficiency and tracks user breathing rhythm more accurately.</li>
<li data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Fit Checker: </b>Easily perform a fit test by simply pulling the lever.</li>
<li data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Under Chin: </b>Unique curved design enhances the airtight seal at the face contact area.</li>
<li data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">Micron: </b>High-performance electrostatic filter material used in Micron filters.</li>
<li data-path-to-node="9"><b data-path-to-node="9" data-index-in-node="0">Speaker: </b>Integrated small communication speaker ensures clear dialogue while wearing the mask.</li>
<li data-path-to-node="11"><b data-path-to-node="11" data-index-in-node="0">Special Hard Coating: </b>Improved scratch resistance compared to standard surface hardening methods.</li>
<li data-path-to-node="12,0,0"><b data-path-to-node="14" data-index-in-node="0">Silicone: </b>The facepiece uses high-grade silicone material for a soft, skin-friendly fit.</li>
<li data-path-to-node="16"><b data-path-to-node="16" data-index-in-node="0">Speaking Diaphragm: </b>Facilitates clear communication and instruction without mask removal.</li>
<li data-path-to-node="18"><b data-path-to-node="18" data-index-in-node="0">Internal Pressure Monitoring: </b>Flashing light alerts the user when positive pressure is lost inside the facepiece.</li>
<li data-path-to-node="20"><b data-path-to-node="20" data-index-in-node="0">HAWC Lip: </b>Full-face models use the HAWC Lip structure for a high-seal &#8220;suction effect.&#8221;</li>
<li data-path-to-node="22"><b data-path-to-node="22" data-index-in-node="0">Hardened Eyepiece: </b>The visor surface is treated with a hardening process to resist scratches.</li>
</ul>The post <a href="https://koueitrading.com/global/product/koken-bl-7005-p-papr/">Koken BL-7005 P-PAPR</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken BL-321 Series P-PAPR</title>
		<link>https://koueitrading.com/global/product/koken-bl-321-series-p-papr/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Wed, 04 Mar 2020 07:05:22 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=191669</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: BL-321 Series P-PAPR: Powered Air-Purifying Particulate Respirator PARTICULATE PAPR and GAS PAPR PAPR: Powered Air-Purifying Respirator. P-PAPR: Particulate PAPR (Used for dust/particles). G-PAPR: Gas PAPR (Used for toxic gases/vapors). Within the PAPR range, there are “Powered Air-Purifying Particulate Respirators (P-PAPR)” for dust hazards and “Powered Air-Purifying Gas Respirators (G-PAPR)” for toxic [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-bl-321-series-p-papr/">Koken BL-321 Series P-PAPR</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: BL-321 Series</p>
<p>P-PAPR: Powered Air-Purifying Particulate Respirator</p>
<h2>PARTICULATE PAPR and GAS PAPR</h2>
<ul>
<li data-path-to-node="14,0,0">PAPR: Powered Air-Purifying Respirator.</li>
<li data-path-to-node="14,1,0">P-PAPR: Particulate PAPR (Used for dust/particles).</li>
<li data-path-to-node="14,2,0">G-PAPR: Gas PAPR (Used for toxic gases/vapors).</li>
</ul>
<p data-path-to-node="3">Within the PAPR range, there are “Powered Air-Purifying Particulate Respirators (P-PAPR)” for dust hazards and “Powered Air-Purifying Gas Respirators (G-PAPR)” for toxic gas hazards. It is essential to understand the properties, type, and concentration of the hazardous substances before selecting the appropriate mask.</p>
<p data-path-to-node="3">To prevent inhalation of DUST -&gt; Use a Powered Air-Purifying Particulate Respirator (P-PAPR)<br />
To prevent inhalation of TOXIC GAS -&gt; Use a Powered Air-Purifying Gas Respirator (G-PAPR)<br />
To prevent inhalation of MIXED DUST &amp; TOXIC GAS -&gt; Use a Powered Air-Purifying Gas Respirator (G-PAPR) with dust protection function</p>
<h3>Environments where PAPR CANNOT be used</h3>
<p data-path-to-node="9">PAPR must not be used if any of the following conditions apply. Please use respiratory protective equipment suitable for the environment, such as a supplied-air respirator or a self-contained breathing apparatus (SCBA).</p>
<ul>
<li data-path-to-node="10,0,0">Oxygen-deficient environments or those at risk of oxygen deficiency (Oxygen concentration below 18%).</li>
<li data-path-to-node="10,1,0">Cases where the type or concentration of the toxic gas is unknown.</li>
<li data-path-to-node="10,2,0">IDLH environments (Atmospheres Immediately Dangerous to Life or Health).</li>
<li data-path-to-node="10,2,0">Cases where the toxic gas concentration exceeds the permissible limit for the PAPR. ※</li>
<li data-path-to-node="10,3,0">Cases where no filter (canister) is available to remove the specific toxic gas in the environment.</li>
<li data-path-to-node="10,4,0">Cases where a mixture of gases with different properties exists.</li>
<li data-path-to-node="10,5,0">Cases where the environment deviates significantly from normal temperature, humidity, and atmospheric pressure.</li>
</ul>
<p data-path-to-node="11">(※ According to standards based on the Industrial Safety and Health Act, the application range of G-PAPR is 2% (3% for Ammonia))</p>
<h3>SELECTING THE APPROPRIATE PAPR BASED ON HAZARD CONCENTRATION</h3>
<p data-path-to-node="3">Determine the Required Protection Factor, then select a PAPR model with an Assigned Protection Factor higher than that value.</p>
<p data-path-to-node="4,0">Formula: How to calculate the Required Protection Factor<br />
<strong>Required Protection Factor = Ambient concentration of identified hazard / Permissible exposure limit of the hazard</strong></p>
<p>Assigned Protection Factor of P-PAPR</p>
<table>
<thead>
<tr>
<th colspan="2"><strong>Classification</strong></th>
<th colspan="4"><strong>Facepiece Type</strong></th>
</tr>
<tr>
<th><strong>Leakage Rate</strong></th>
<th><strong>Filter Efficiency</strong></th>
<th><strong>Half-face</strong></th>
<th><strong>Full-face</strong></th>
<th><strong>Hood Type</strong></th>
<th><strong>Face shield</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td rowspan="3">Class S</td>
<td>PL3/PS3</td>
<td>50/300</td>
<td>1000</td>
<td>25/1000</td>
<td>25/300</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>—</td>
<td>—</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td rowspan="3">Class A</td>
<td>PL3/PS3</td>
<td>—</td>
<td>—</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>33</td>
<td>90</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>14</td>
<td>19</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td rowspan="3">Class B</td>
<td>PL3/PS3</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>14</td>
<td>19</td>
<td>11</td>
<td>11</td>
</tr>
</tbody>
</table>
<p>Assigned Protection Factor of G-PAPR</p>
<table>
<thead>
<tr>
<th class="header-main" colspan="4"><strong>Facepiece Type</strong></th>
</tr>
<tr>
<th><strong>Half-face</strong></th>
<th><strong>Full-face</strong></th>
<th><strong>Hood Type</strong></th>
<th><strong>Face shield</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>50/300</td>
<td>1000</td>
<td>25/1000</td>
<td>25/300</td>
</tr>
</tbody>
</table>
<p>For “G-PAPR with dust protection function,” please refer to the Assigned Protection Factor of P-PAPR (Class S leakage rate) mentioned above for dust (and similar particulates).</p>
<h2>TASKS WHERE PAPR USE IS MANDATORY BY REGULATION OR DIRECTIVE</h2>
<p><strong>For tasks where PAPR use is mandatory by regulation or directive, please use a PAPR with the designated performance classification.</strong></p>
<h4><strong>1. Tunnel Construction Work</strong></h4>
<p><strong>Regulation:</strong> “Ordinance on Prevention of Pneumoconiosis”<br />
<strong>Scope:</strong> In tunnel construction, at locations involving “mechanical/powered excavation,” “mechanical loading or unloading of ore/rock,” and “shotcreting.”</p>
<p><strong>PAPR Requirements:</strong></p>
<ul>
<li>National test certified product (High airflow type).</li>
<li>Tight-fitting facepiece type where the battery can be removed for use during blasting operations.</li>
</ul>
<h4><strong>2. Asbestos Removal Work</strong></h4>
<p><strong>Regulation:</strong> “Ordinance on Prevention of Health Impairment due to Asbestos”<br />
<strong>Scope</strong>: In asbestos removal tasks, specifically those requiring “Class 1 Asbestos Removal Masks.”<br />
<b data-path-to-node="11,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified tight-fitting or hood types (High airflow, Class S, PL3 or PS3).</p>
<h4 data-path-to-node="12"><b data-path-to-node="12" data-index-in-node="0">3. Handling Nanomaterials</b></h4>
<p data-path-to-node="13,0,0"><b data-path-to-node="13,0,0" data-index-in-node="0">Directive:</b> “Regarding Preventive Measures for Exposure to Nanomaterials”<br />
<b data-path-to-node="13,1,0" data-index-in-node="0">Scope:</b> Manufacturing and handling of nanomaterials. (※)<br />
<b data-path-to-node="13,2,0" data-index-in-node="0">PAPR Requirements:</b></p>
<ul>
<li data-path-to-node="13,2,0">National test certified product (High airflow, PL3 or PS3).</li>
<li data-path-to-node="13,2,1,0,0">Shape limitations based on the projected exposure levels of workers.</li>
</ul>
<p data-path-to-node="13,2,1,1,0">(※) Depending on the work environment, respiratory protective equipment other than PAPR may be used.</p>
<h4 data-path-to-node="14"><b data-path-to-node="14" data-index-in-node="0">4. Handling Indium</b></h4>
<p data-path-to-node="15,0,0"><b data-path-to-node="15,0,0" data-index-in-node="0">Directive:</b> “Regarding Thorough Health Hazard Prevention Measures for Indium/Tin Oxide Handling”<br />
<b data-path-to-node="15,1,0" data-index-in-node="0">Scope:</b> Handling of Indium, Tin Oxide, etc. (※)<br />
<b data-path-to-node="15,2,0" data-index-in-node="0">PAPR Requirements:</b></p>
<ul>
<li data-path-to-node="15,2,0">National test certified product (High airflow, PL3 or PS3).</li>
<li data-path-to-node="15,2,1,0,0">Limitations on shape and leakage rate based on working environment measurement results.</li>
</ul>
<p data-path-to-node="15,2,1,1,0">(※) Depending on environmental results, respiratory protective equipment other than PAPR may be used.</p>
<h4 data-path-to-node="16"><b data-path-to-node="16" data-index-in-node="0">5. Handling Dioxins</b></h4>
<p><b data-path-to-node="17,0,0" data-index-in-node="0">Directive:</b> “Revision of Guidelines for Dioxin Exposure Prevention in Waste Incineration Facilities”<br />
<b data-path-to-node="17,1,0" data-index-in-node="0">Scope:</b> For dioxin-exposure risk tasks classified as “Level 1.” (※)<br />
<b data-path-to-node="17,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified product (High airflow, PL3 or PS3).</p>
<p>(※) RL3 or RS3 dust masks may be used, but PAPR with higher protective performance is recommended.</p>
<h4 data-path-to-node="18"><b data-path-to-node="18" data-index-in-node="0">6. Handling Refractory Ceramic Fibers (RCF)</b></h4>
<p><b data-path-to-node="19,0,0" data-index-in-node="0">Regulation:</b> “Ordinance on Prevention of Hazards due to Specified Chemical Substances”<br />
<b data-path-to-node="19,1,0" data-index-in-node="0">Scope:</b> Insulation or fireproofing work involving the application of RCF to furnaces or boilers; or repair, dismantling, and demolition of such furnaces/boilers.<br />
<b data-path-to-node="19,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified product (PL3 or PS3).</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong>PAPR Standards</strong></th>
<td width="64">Beyond JIS standards, Powered Air-Purifying Respirators must adhere to standards defined under the Industrial Safety and Health Act. These comprehensive standards ensure that products are manufactured under strict safety requirements.</td>
</tr>
</tbody>
</table>
<p>The following table is excerpted from the ‘Standards for Powered Air-Purifying Respirators’</p>
<h3>Types of Powered Air-Purifying Respirators</h3>
<table>
<tbody>
<tr>
<th colspan="2"><strong>Powered Air-Purifying Particulate Respirator (P-PAPR)</strong></th>
</tr>
<tr>
<th rowspan="2"><strong>Powered Air-Purifying Gas Respirator (G-PAPR)</strong></th>
<td>Type with dust protection function</td>
</tr>
<tr>
<td>Type without dust protection function</td>
</tr>
</tbody>
</table>
<p><strong>■ Classification by Shape</strong></p>
<table>
<tbody>
<tr>
<th rowspan="2"><strong>Tight-fitting Facepiece</strong><br />
<span class="sub-item">・Full-face</span><br />
<span class="sub-item">・Half-face</span></th>
<td>Isolation type (with hose)</td>
</tr>
<tr>
<td>Direct connection type</td>
</tr>
<tr>
<th rowspan="2"><strong>Loose-fitting Facepiece</strong><br />
<span class="sub-item">・Hood</span><br />
<span class="sub-item">・Face shield</span></th>
<td>Isolation type (with hose)</td>
</tr>
<tr>
<td>Direct connection type</td>
</tr>
</tbody>
</table>
<p><strong>■ Classification by Performance</strong></p>
<table>
<thead>
<tr>
<th><strong>Airflow Performance Classification</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>Standard airflow type</td>
</tr>
<tr>
<td>High airflow type</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th><strong>Leakage Rate Performance Classification (P-PAPR)</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>Class B</td>
</tr>
<tr>
<td>Class A</td>
</tr>
<tr>
<td>Class S</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th colspan="2"><strong>Filter Material Performance Classification<br />
(P-PAPR and G-PAPR with dust function)</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td width="50%">PS1</td>
<td width="50%">PL1</td>
</tr>
<tr>
<td>PS2</td>
<td>PL2</td>
</tr>
<tr>
<td>PS3</td>
<td>PL3</td>
</tr>
</tbody>
</table>
<h3>Performance Testing for Powered Air-Purifying Respirators</h3>
<h4><strong>■ Particle Collection Efficiency Test</strong></h4>
<p>(Applies only to P-PAPR and G-PAPR with dust protection)</p>
<table>
<tbody>
<tr>
<th class="header-bg col-label" rowspan="3"><strong>Test Particle</strong></th>
<th class="header-bg col-sub"><strong>Type</strong></th>
<td class="align-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="align-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="header-bg"><strong>Particle Size</strong></th>
<td colspan="2">0.06μm ~ 0.1μm</td>
<td colspan="2">0.15μm ~ 0.25μm</td>
</tr>
<tr>
<th class="header-bg"><strong>Concentration</strong></th>
<td colspan="2">50mg/m³ or less</td>
<td colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="header-bg" rowspan="2"><strong>Test Flow Rate</strong></th>
<th class="header-bg"><strong>Standard Flow</strong></th>
<td colspan="4">104 L/min</td>
</tr>
<tr>
<th class="header-bg"><strong>High Flow</strong></th>
<td colspan="4">138 L/min</td>
</tr>
<tr>
<th class="header-bg align-left" colspan="2" rowspan="4"><strong>Collection Efficiency<br />
(Continuous measurement; must meet values in the right column)</strong></th>
<td colspan="2">For NaCl, loaded up to 200mg</td>
<td colspan="2">For DOP, loaded up to 400mg</td>
</tr>
<tr>
<td class="col-val">PS1</td>
<td class="col-res">95.0% or more</td>
<td class="col-val">PL1</td>
<td class="col-res">95.0% or more</td>
</tr>
<tr>
<td>PS2</td>
<td>99.0% or more</td>
<td>PL2</td>
<td>99.0% or more</td>
</tr>
<tr>
<td>PS3</td>
<td>99.97% or more</td>
<td>PL3</td>
<td>99.97% or more</td>
</tr>
</tbody>
</table>
<h4><strong>■ Canister Testing</strong></h4>
<p>(Applies only to G-PAPR)</p>
<table>
<tbody>
<tr>
<th><strong>Airtightness</strong></th>
<td class="align-left" colspan="4">No air leakage at 1470 Pa pressure</td>
</tr>
<tr>
<th rowspan="5"><strong>Decontamination Capacity<br />
(Time until breakthrough at specified concentration must be ≥ the right column)</strong></th>
<th><strong>Type</strong></th>
<th><strong>Test Gas</strong></th>
<th><strong>Breakthrough Concentration</strong></th>
<th><strong>Duration</strong></th>
</tr>
<tr>
<td>Halogen gas</td>
<td>Chlorine (0.02%)</td>
<td>1 ppm</td>
<td>40 mins or more</td>
</tr>
<tr>
<td>Organic gas</td>
<td>Cyclohexane (0.03%)</td>
<td>5 ppm</td>
<td>50 mins or more</td>
</tr>
<tr>
<td>Ammonia</td>
<td>Ammonia (0.1%)</td>
<td>50 ppm</td>
<td>40 mins or more</td>
</tr>
<tr>
<td>SO₂ gas</td>
<td>Sulfur dioxide (0.03%)</td>
<td>5 ppm</td>
<td>35 mins or more</td>
</tr>
<tr>
<th><strong>Leakage Concentration</strong></th>
<td class="align-left" colspan="4">At maximum flow rate, time to reach breakthrough must be ≥ 3 minutes.</td>
</tr>
</tbody>
</table>
<h4><strong>■ Inward Leakage Rate Test</strong></h4>
<table>
<colgroup>
<col />
<col />
<col />
<col /></colgroup>
<tbody>
<tr>
<th rowspan="3"><strong>Test Particle</strong></th>
<th><strong>Type</strong></th>
<td colspan="4">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<th><strong>Particle Size</strong></th>
<td colspan="4">0.06μm ~ 0.2μm</td>
</tr>
<tr>
<th><strong>Concentration</strong></th>
<td colspan="4">18mg/m³ or less</td>
</tr>
<tr>
<th rowspan="4"><strong>Simulated Breathing</strong></th>
<th><strong>Type</strong></th>
<td colspan="2">Standard Flow</td>
<td colspan="2">High Flow</td>
</tr>
<tr>
<th><strong>Waveform</strong></th>
<td colspan="4">Sine wave</td>
</tr>
<tr>
<th><strong>Ventilation Volume</strong></th>
<td colspan="2">1.5 ± 0.075 L/stroke</td>
<td colspan="2">1.6 ± 0.08 L/stroke</td>
</tr>
<tr>
<th><strong>Frequency</strong></th>
<td colspan="2">20 times/min</td>
<td colspan="2">25 times/min</td>
</tr>
<tr>
<th colspan="2" rowspan="4"><strong>Leakage Rate<br />
(2-minute continuous measurement; max value must meet the right column)</strong></th>
<td rowspan="3">P-PAPR</td>
<td>Class B</td>
<td colspan="2">5.0% or less</td>
</tr>
<tr>
<td>Class A</td>
<td colspan="2">1.0% or less</td>
</tr>
<tr>
<td>Class S</td>
<td colspan="2">0.1% or less</td>
</tr>
<tr>
<td>G-PAPR</td>
<td colspan="3">0.1% or less</td>
</tr>
<tr>
<th colspan="2" rowspan="4"><strong>Headform Movement<br />
(Calculate leakage rate for each item)</strong></th>
<th colspan="3"><strong>Position and Range</strong></th>
<th><strong>Frequency</strong></th>
</tr>
<tr>
<td rowspan="2">Head</td>
<td colspan="2">Front/Back 30 degrees</td>
<td>17 times/min</td>
</tr>
<tr>
<td colspan="2">Left/Right rotation 50 degrees</td>
<td>11 times/min</td>
</tr>
<tr>
<td>Arms</td>
<td colspan="2">Raising 10 ~ 130 degrees</td>
<td>7 times/min</td>
</tr>
</tbody>
</table>
<h4><strong>■ Other Tests</strong></h4>
<table>
<tbody>
<tr>
<th><strong>Internal Pressure<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">Under simulated breathing identical to the leakage test:<br />
0 Pa &lt; Internal Mask Pressure &lt; 400 Pa</td>
</tr>
<tr>
<th rowspan="2"><strong>Minimum Required Flow<br />
(Loose-fit only)</strong></th>
<td class="align-center">Standard Flow</td>
<td class="align-center">104 L/min or more</td>
</tr>
<tr>
<td class="align-center">High Flow</td>
<td class="align-center">138 L/min or more</td>
</tr>
<tr>
<th><strong>Inhalation Resistance<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">160 Pa or less<br />
(40 L/min flow rate, fan OFF)</td>
</tr>
<tr>
<th><strong>Exhalation Resistance<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">80 Pa or less<br />
(40 L/min flow rate, fan OFF)</td>
</tr>
<tr>
<th><strong>Exhalation Valve Airtightness<br />
(Tight-fitting only)</strong></th>
<td class="content-cell" colspan="2">・Internal pressure must drop immediately when air is sucked.<br />
・Time for pressure to return to normal must be ≥ 15 seconds.</td>
</tr>
<tr>
<th><strong>CO2 Concentration Increase<br />
(Tight-fitting only)</strong></th>
<td class="content-cell" colspan="2">With fan OFF, headform breathes CO2 air. Difference between wearing and not wearing mask must be &lt; 2.0%.</td>
</tr>
<tr>
<th><strong>Noise Level</strong></th>
<td class="align-center" colspan="2">Noise at the headform ear area must be below 80 dB (both sides).</td>
</tr>
<tr>
<th rowspan="4"><strong>Flow Rate<br />
(G-PAPR only)</strong></th>
<td>Max set average flow</td>
<td class="content-cell">Average must be ≤ the decontamination test flow rate.</td>
</tr>
<tr>
<td>Maximum flow</td>
<td class="content-cell">Maximum must be ≤ the flow rate set by the manufacturer.</td>
</tr>
<tr>
<th><strong>Tight-fitting type</strong></th>
<th><strong>Loose-fitting type</strong></th>
</tr>
<tr>
<td class="content-cell">Measure resistance with fan OFF/ON at 20~170 L/min to calculate flow per minute.</td>
<td class="content-cell">With fan ON, draw air for 5 mins to maintain normal pressure in chamber, then measure flow.</td>
</tr>
</tbody>
</table>
<h2>PAPR USE IS ENCOURAGED IN THE 10TH COMPREHENSIVE DUST HAZARD COUNTERMEASURES</h2>
<p><strong>To reduce pneumoconiosis, dust prevention measures must be strengthened.</strong></p>
<p>The “10th Comprehensive Countermeasures for Preventing Dust Hazards” demands the correct use of effective respiratory protection against dust exposure across all industries. PAPR is highlighted as a “more effective preventive measure for health impairment,” and its adoption is highly encouraged.<br />
The use of PAPR is more effective in preventing health impairment compared to standard dust masks due to its higher protection factor and reduced physical strain on the wearer.<br />
(Partial excerpt from the 10th Comprehensive Countermeasures)</p>
<p>Furthermore, due to high performance, PAPR is mandatory for specific tasks, but its use is also recommended for tasks outside the mandatory categories.<br />
While PAPR is mandatory for specific operations under the Dust Rules, its high performance makes it desirable for other tasks; thus, guidance and inspections encourage businesses to adopt PAPR for their workers.<br />
(Partial excerpt from the 10th Comprehensive Countermeasures)</p>
<h2>KOKEN BL SERIES BREATH-RESPONSIVE PAPR</h2>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Achieving “High Safety” and “Comfortable Fit” as expected</b></p>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">THE EVOLUTION OF THE BL SERIES</b></p>
<p data-path-to-node="6">The BL Series continues to evolve into the PAPR model that helps perfect safety and health management in every field, aligning with occupational health trends and market expansion.</p>
<p data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">CORE DEVELOPMENT FOCUS</b></p>
<ul>
<li data-path-to-node="8,0,0"><b data-path-to-node="8,0,0" data-index-in-node="0">“Safety”:</b> Improving the protection capability as a respirator.</li>
<li data-path-to-node="8,1,0"><b data-path-to-node="8,1,0" data-index-in-node="0">“Flow Technology”:</b> Minimizing waste and improving efficiency.</li>
<li data-path-to-node="8,2,0"><b data-path-to-node="8,2,0" data-index-in-node="0">“Lightweight Design”:</b> Reducing the burden on the worker.</li>
</ul>
<h2>KOKEN FLOW TECHNOLOGY: New BSFS air flow highly synchronized with breathing</h2>
<h3>THE MECHANISM OF THE BSFS (BREATH SYNCHRONIZED) SYSTEM</h3>
<p data-path-to-node="5">The BL Series is equipped with the Breath Synchronized-Air Flow System (new BSFS), which delivers airflow that follows the breathing rhythm more closely than ever, becoming a “Highly Synchronized” model.<br />
BSFS ELIMINATES THE FEELING OF BREATHLESSNESS/STUFFINESS<br />
<img loading="lazy" decoding="async" class="size-medium wp-image-191639 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-300x177.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-300x177.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4.jpg 464w" alt="" width="300" height="177" /></p>
<p><b data-path-to-node="2" data-index-in-node="0">THE BSFS MECHANISM HAS EVOLVED INTO “HIGH SYNCHRONIZATION”</b></p>
<p data-path-to-node="3">Using a fan equipped with a breath detection sensor, the device supplies “the necessary and sufficient amount of air” corresponding to the user’s inhalation. Responsiveness to breathing has been improved, and the accuracy of synchronization with the respiratory rhythm has significantly increased.<br />
<img loading="lazy" decoding="async" class="size-medium wp-image-191638 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-300x286.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-300x286.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-768x733.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1.jpg 1024w" alt="" width="300" height="286" /></p>
<h3>COMFORT UP</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">SOLVING MASK DISCOMFORT WITH FLOW THAT FOLLOWS EVERY BREATH</b></p>
<ul>
<li data-path-to-node="4,0,0">Reduces the physical workload for laborers.</li>
<li data-path-to-node="4,1,0">Solves breathing difficulties and stuffiness in high-temperature workplaces.</li>
</ul>
<h3>SAFETY UP</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">PREVENTING INWARD LEAKAGE THROUGH HIGH PROTECTION AND CONSTANT POSITIVE PRESSURE</b></p>
<p data-path-to-node="4,0,0">Breath Synchronization: Protection is guaranteed by the blower linked to breathing.</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class=" wp-image-191633 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-300x227.jpg" sizes="auto, (max-width: 441px) 100vw, 441px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-300x227.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-768x581.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6.jpg 1024w" alt="" width="441" height="334" /></td>
<td width="64"><img loading="lazy" decoding="async" class=" wp-image-191636 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-300x218.png" sizes="auto, (max-width: 508px) 100vw, 508px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-300x218.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-1024x745.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-768x559.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185.png 1407w" alt="" width="508" height="369" /></td>
</tr>
<tr>
<td height="19">
<p data-path-to-node="3,0,0"><b data-path-to-node="3,0,0" data-index-in-node="0">DURING INHALATION:</b> Air inside the mask is normally sucked away, but supplemental airflow prevents negative pressure. (If a gap exists, air blows outward ※1)</p>
<p data-path-to-node="3,0,0">※1: Airflow varies based on facepiece fit.</p>
</td>
<td>
<p data-path-to-node="3,1,0"><b data-path-to-node="3,1,0" data-index-in-node="0">DURING EXHALATION:</b> Since pressure doesn’t drop, airflow is reduced. This conserves the “filter” and “battery.”</p>
<p data-path-to-node="3,1,0">※2: Flow doesn’t stop completely (maintains a small amount for safety).</p>
</td>
</tr>
</tbody>
</table>
<p><b data-path-to-node="2" data-index-in-node="0">PAPR AVOIDS HIGH LEAKAGE RISKS FROM DUST BUILDUP IN LOOSE MASKS</b></p>
<p data-path-to-node="3">FOR CONVENTIONAL DUST MASKS:</p>
<p data-path-to-node="4">As dust builds on the filter, inhalation resistance increases, raising the risk of inward leakage. As dust accumulates, even if the gap remains the same, the leakage rate can double. (See diagram below)</p>
<p><img loading="lazy" decoding="async" class=" wp-image-191632 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-300x195.jpg" sizes="auto, (max-width: 409px) 100vw, 409px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-300x195.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-768x500.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-180x118.jpg 180w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8.jpg 1024w" alt="" width="409" height="266" /></p>
<p><b data-path-to-node="7" data-index-in-node="0">Leakage Measurement Method:</b> A 2.5% gap is created intentionally; NaCl concentration is measured inside/outside the mask with a digital meter.</p>
<h3>ECONOMY UP (ECO)</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">ELIMINATING WASTE THROUGH AN ECO FLOW MECHANISM</b></p>
<p data-path-to-node="4,0,0">Limits “wasteful dust buildup” and reduces filter usage: Minimizes air loss to reduce clogging.<br />
Limits battery usage: Extends runtime by reducing power consumption during low-respiration phases.</p>
<p><b data-path-to-node="2" data-index-in-node="0">BATTERY RUNTIME COMPARISON: NEW VS OLD BSFS</b></p>
<p data-path-to-node="3"><img loading="lazy" decoding="async" class=" wp-image-191631 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/1-300x126.png" sizes="auto, (max-width: 445px) 100vw, 445px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/1-300x126.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-1024x429.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-768x322.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/1.png 1536w" alt="" width="445" height="187" /></p>
<p data-path-to-node="3"><strong>ECO FLOW CREATED BY HIGH SYNCHRONIZATION</strong></p>
<p data-path-to-node="3"><img loading="lazy" decoding="async" class=" wp-image-191630 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/2-300x175.png" sizes="auto, (max-width: 456px) 100vw, 456px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/2-300x175.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-1024x599.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-768x449.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/2.png 1536w" alt="" width="456" height="266" />Image of BSFS flow following actual respiratory waveforms with high precision.</p>
<h2 data-path-to-node="3">KOKEN LIGHTWEIGHT DESIGN: Reducing burden for long shifts</h2>
<p>The “BL Series” optimizes compact sizing and weight equivalent to conventional dust masks. It is highly rated in tunnel construction, asbestos handling, and arc welding.</p>
<p><b data-path-to-node="4" data-index-in-node="0">SEPARATE TYPE</b> Because a direct-mounted battery adds weight to the neck, the separate design reduces perceived weight. This ultra-lightweight design minimizes mask body thickness.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56541" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-122956.png" alt="" width="348" height="302" /></p>
<p><b data-path-to-node="5" data-index-in-node="0">BUILT-IN TYPE</b> Thanks to “High Synchro” BSFS reducing power draw, battery size has been shrunk. This results in a lightweight built-in battery design with minimal burden.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56542" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123026.png" alt="" width="212" height="269" /></p>
<h2>KOKEN SAFETY DESIGN: Internal pressure monitoring to maintain positive pressure</h2>
<p data-path-to-node="3">(Common for BL-321/BL-351/BL-351X/BL-711/BL-700/BL-200/BL-100 series)</p>
<p data-path-to-node="4">Modern worksites require PAPRs that “constantly monitor internal pressure and provide alerts.”<br />
PAPR is most protective under positive pressure; therefore, the moment positive pressure cannot be maintained is the filter replacement time. “Internal monitoring” notifies the user when pressure drops due to weak flow.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56543" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123245.png" alt="" width="243" height="253" /></p>
<p data-path-to-node="7,0,0">■ Positive pressure inside the mask can be maintained through timely/appropriate filter replacement.<br />
■ Clarifies the standard for filter replacement – which is otherwise often vague or based on subjective estimation.<br />
■ Full airflow can be restored through proper battery charging.</p>
<p><b data-path-to-node="2" data-index-in-node="0">NOTIFICATION VIA AIRFLOW</b></p>
<p data-path-to-node="3">(For BL-321 / BL-351 / BL-351X / BL-711 series)</p>
<ul>
<li data-path-to-node="4,0,0">Pressure drop warning via “Continuous Airflow”: ➔ Replace the filter.</li>
<li data-path-to-node="4,1,0">Low battery warning via “Rhythmic Airflow”: ➔ Replace with a charged battery.</li>
</ul>
<p><b data-path-to-node="6" data-index-in-node="0">LED NOTIFICATION</b></p>
<p data-path-to-node="7">(For BL-700 / BL-200 / BL-100 series)</p>
<ul>
<li data-path-to-node="8,0,0">Pressure drop warning via “Flashing LED”: ➔ Replace the filter.</li>
<li data-path-to-node="8,1,0">Low battery warning via “Steady LED”: ➔ Replace with a charged battery.</li>
</ul>
<p><img loading="lazy" decoding="async" class=" wp-image-191629 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/3-300x65.png" sizes="auto, (max-width: 471px) 100vw, 471px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/3-300x65.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-1024x221.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-768x166.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/3.png 1536w" alt="" width="471" height="102" /></p>
<h2>POWERED AIR-PURIFYING PARTICULATE RESPIRATOR (P-PAPR)</h2>
<p>[HALF FACEPIECE TYPE]</p>
<h3>BL-321 SERIES</h3>
<p data-path-to-node="2"><b data-path-to-node="2" data-index-in-node="0">Lightest model among high-airflow cordless PAPRs (※)<br />
</b>(※ Cordless PAPRs sold in Japan as of October 2024 (Per company research))</p>
<p data-path-to-node="3,1,0"><b data-path-to-node="3,1,0" data-index-in-node="0">Classification:</b> <b data-path-to-node="3,1,0" data-index-in-node="11">HIGH AIRFLOW TYPE</b></p>
<p data-path-to-node="4"><b data-path-to-node="4" data-index-in-node="0">Key Features:</b></p>
<ul>
<li data-path-to-node="5,0,0">High Synchro</li>
<li data-path-to-node="5,1,0">Under Chin design</li>
<li data-path-to-node="5,2,0">Silicone material</li>
<li data-path-to-node="5,3,0">Speaking Diaphragm</li>
</ul>
<p data-path-to-node="1,0,0">■ High water resistance (IP55 rating) prevents moisture ingress.<br />
■ Integrated &#8220;Speaking Diaphragm&#8221; for clear communication.<br />
■ &#8220;Auto ON/OFF&#8221; function: Fan starts automatically upon inhalation.<br />
■ Low battery warning via &#8220;Airflow Notification.&#8221;</p>
<p data-path-to-node="1"><b data-path-to-node="1" data-index-in-node="0">Shared Facepiece Body<br />
</b>Versatile use by switching filters based on application.</p>
<ul>
<li data-path-to-node="2,0,1,0,0">Install BLA-62 for BL-321S configuration</li>
<li data-path-to-node="2,0,1,1,0">Install BRD-82 for BL-321H configuration</li>
</ul>
<h3><b data-path-to-node="1" data-index-in-node="0">Sakai Type</b> <b data-path-to-node="1" data-index-in-node="11">BL-321S-02</b></h3>
<p>Includes battery &amp; charger. Pattern Test Cert TP100<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56582" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_152112-removebg-preview.png" alt="" width="213" height="266" /><br />
Integrated lightweight battery<br />
Lightest model at approx 240g</p>
<ul>
<li data-path-to-node="2,0,0">PL1 efficiency</li>
<li data-path-to-node="2,1,0">Class B leakage</li>
<li data-path-to-node="2,2,0">Assigned Protection Factor: 14</li>
</ul>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Applications:</b></p>
<ul>
<li data-path-to-node="4,0,0">General Dust</li>
<li data-path-to-node="4,1,0">Tunnel Construction</li>
</ul>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Replacement Filter: </b>Alpha Ring Filter BLA-62</p>
<p data-path-to-node="5"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56583" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-152429.png" alt="" width="155" height="194" /></p>
<p data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">Note: </b>BL-321S includes &#8220;BL Cover Type 1&#8221; to prevent dust buildup.</p>
<h3><b data-path-to-node="7" data-index-in-node="0">Sakai Type</b> <b data-path-to-node="1" data-index-in-node="11">BL-321H-02</b></h3>
<p>Includes battery &amp; charger. Pattern Test Cert TP101</p>
<p data-path-to-node="7"><img loading="lazy" decoding="async" class="aligncenter wp-image-56584" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_152510-removebg-preview.png" alt="" width="217" height="254" /></p>
<ul>
<li data-path-to-node="2,0,0">PL3 efficiency</li>
<li data-path-to-node="2,1,0">Class S leakage</li>
<li data-path-to-node="2,2,0">Assigned Protection Factor: 300 (※)</li>
</ul>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Applications:</b></p>
<ul>
<li data-path-to-node="4,0,0">Asbestos removal</li>
<li data-path-to-node="4,1,0">Indium handling</li>
<li data-path-to-node="4,2,0">RCF (Refractory Ceramic Fiber) handling</li>
<li data-path-to-node="4,3,0">Dioxin (Level 1)</li>
<li data-path-to-node="4,4,0">Tunnel construction</li>
</ul>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Replacement Filter: </b>Alpha Ring Filter BRD-82</p>
<p data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">Note: </b>For tunnel construction, please use the BL-321H-02 set which includes the battery, charger, and protective cover.</p>
<p data-path-to-node="7">(※) Based on Simulated Workplace Protection Factor (SWPF) measurements conducted by our company, proving the protection factor exceeds 300.</p>
<h3>EASY MAINTENANCE FOR DUST ACCUMULATION</h3>
<p data-path-to-node="2,0,0">For persistent dust that cannot be removed by wiping, the unit can be cleaned by rinsing with water.</p>
<p data-path-to-node="2,0,0">(Caution) Always use the maintenance-specific sealing plugs. Do not submerge the unit in water or allow water to enter the internal facepiece. Batteries and filters are not washable. Please follow the individual product manuals.</p>
<table>
<tbody>
<tr>
<th class="xl65" colspan="4" width="256" height="19"><strong>BL-711 SERIES, BL-700 SERIES</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56551" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-132647.png" alt="" width="186" height="145" /></td>
<td>
<p data-path-to-node="2,0,0"><b data-path-to-node="2,0,0" data-index-in-node="0">Mask Part:</b></p>
<p data-path-to-node="2,0,1,0,0">After removing the fan unit and speaker unit (※), the mask can be rinsed with water.<br />
(※ Speaker removal applies only to BL-711 series)</p>
</td>
<td><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56552" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-132703.png" alt="" width="188" height="145" /></td>
<td>
<p data-path-to-node="2,1,0"><b data-path-to-node="2,1,0" data-index-in-node="0">Fan Unit Part:</b></p>
<p data-path-to-node="2,1,1,0,0">Using sealing plugs, the unit can be cleaned with a damp cloth, etc.</p>
</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<th class="xl65" colspan="2" width="128" height="19"><strong>BL-321, BL-351X, BL-351 SERIES</strong></th>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56553" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-132717.png" alt="" width="187" height="143" /></td>
<td>Using sealing plugs, these models can be cleaned by rinsing off external dirt with water.</td>
</tr>
</tbody>
</table>
<h3>Performance Specifications</h3>
<table class="spec-table">
<thead>
<tr>
<th rowspan="2"><strong>Product Name</strong></th>
<th colspan="3"><strong>Classification</strong></th>
<th rowspan="2"><strong>Collection Efficiency</strong></th>
<th rowspan="2"><strong>Weight (incl. battery)</strong></th>
<th rowspan="2"><strong>Facepiece Weight</strong></th>
<th rowspan="2"><strong>Battery Specs</strong></th>
<th rowspan="2"><strong>Nominal Runtime*1</strong></th>
<th rowspan="2"><strong>Actual Runtime*2</strong></th>
<th rowspan="2"><strong>Fan Lifespan</strong></th>
</tr>
<tr>
<th><strong>Fan Type</strong></th>
<th><strong>Leakage Rate</strong></th>
<th><strong>Filter Grade</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td class="product">BL-711H</td>
<td rowspan="4">High Airflow</td>
<td rowspan="4">Class S (≤0.1%)</td>
<td rowspan="4">PL3</td>
<td>99.97% or more</td>
<td colspan="2">≤753g (Avg 723g)</td>
<td class="left" rowspan="4">Li-ion Rechargeable<br />
Voltage: 7.2V<br />
Capacity: 2000mAh<br />
Charging: ~3 hours*3<br />
Cycles: ~300 times*3</td>
<td rowspan="2">Approx. 6 hours</td>
<td rowspan="2">Approx. 6.5–10 hours</td>
<td rowspan="20">Approx. 2,000 hours*3</td>
</tr>
<tr>
<td class="product">BL-711U</td>
<td>99.99% or more</td>
<td colspan="2">≤753g (Avg 720g)</td>
</tr>
<tr>
<td class="product">BL-700HA</td>
<td>99.97% or more</td>
<td rowspan="2">≤774g</td>
<td rowspan="2">Avg 591g</td>
<td rowspan="2">Approx. 7.5 hours</td>
<td rowspan="2">Approx. 8–14.5 hours</td>
</tr>
<tr>
<td class="product">BL-700U</td>
<td>99.99% or more</td>
</tr>
<tr>
<td class="product">BL-7005/AL</td>
<td rowspan="3">Standard Airflow</td>
<td rowspan="3">Class A (≤1.0%)</td>
<td>PL2</td>
<td>99.0% or more</td>
<td colspan="2">≤298g (Avg 288g)</td>
<td rowspan="5">Li-ion Rechargeable<br />
Voltage: 3.7V<br />
Capacity: 1100mAh<br />
Charging: ~3 hours*3<br />
Cycles: ~300 times*3</td>
<td>Approx. 6.7 hours</td>
<td>Approx. 4–9 hours</td>
</tr>
<tr>
<td class="product">BL-1005/AL</td>
<td rowspan="3">PL1</td>
<td>95.0% or more</td>
<td colspan="2">≤278g (Avg 271g)</td>
<td rowspan="2">Approx. 8.5 hours</td>
<td rowspan="2">Approx. 3.5–11 hours</td>
</tr>
<tr>
<td class="product">BL-1005X/AL</td>
<td>95.0% or more</td>
<td colspan="2">≤285g (Avg 278g)</td>
</tr>
<tr>
<td class="product">BL-321S</td>
<td rowspan="13">High Airflow</td>
<td>Class B (≤5.0%)</td>
<td>95.0% or more</td>
<td colspan="2">≤252g (Avg 244g)</td>
<td>Approx. 3.5 hours</td>
<td>Approx. 5–9 hours</td>
</tr>
<tr>
<td class="product">BL-321H</td>
<td>Class S (≤0.1%)</td>
<td>PL3</td>
<td>99.97% or more</td>
<td colspan="2">≤265g (Avg 257g)</td>
<td>Approx. 3 hours</td>
<td>Approx. 3–6 hours</td>
</tr>
<tr>
<td class="product">BL-351S</td>
<td>Class B (≤5.0%)</td>
<td>PL1</td>
<td>95.0% or more</td>
<td colspan="2">Avg 315g</td>
<td rowspan="11">Li-ion Rechargeable<br />
Voltage: 7.2V<br />
Capacity: 2000mAh<br />
Charging: ~3 hours*3<br />
Cycles: ~300 times*3</td>
<td>Approx. 10 hours</td>
<td>Approx. 13–22 hours</td>
</tr>
<tr>
<td class="product">BL-351H</td>
<td rowspan="3">Class S (≤0.1%)</td>
<td rowspan="3">PL3</td>
<td>99.97% or more</td>
<td colspan="2" rowspan="2">Avg 328g</td>
<td rowspan="3">Approx. 9 hours</td>
<td rowspan="3">Approx. 8–17 hours</td>
</tr>
<tr>
<td class="product">BL-351U</td>
<td>99.99% or more</td>
</tr>
<tr>
<td class="product">BL-351HX</td>
<td>99.97% or more</td>
<td colspan="2">Avg 333g</td>
</tr>
<tr>
<td class="product">BL-200S</td>
<td>Class B (≤5.0%)</td>
<td>PL1</td>
<td>95.0% or more</td>
<td>≤395g</td>
<td>Avg 219g</td>
<td>Approx. 10.5 hours</td>
<td>Approx. 12–22 hours</td>
</tr>
<tr>
<td class="product">BL-200H</td>
<td rowspan="2">Class S (≤0.1%)</td>
<td rowspan="2">PL3</td>
<td>99.97% or more</td>
<td rowspan="2">≤409g</td>
<td rowspan="2">Avg 234g</td>
<td rowspan="2">Approx. 9.5 hours</td>
<td rowspan="2">Approx. 10–18 hours</td>
</tr>
<tr>
<td class="product">BL-200U</td>
<td>99.99% or more</td>
</tr>
<tr>
<td class="product">BL-100S</td>
<td rowspan="2">Class B (≤5.0%)</td>
<td rowspan="2">PL1</td>
<td rowspan="2">95.0% or more</td>
<td rowspan="2">≤383g</td>
<td rowspan="2">Avg 206g</td>
<td rowspan="2">Approx. 10 hours</td>
<td rowspan="2">Approx. 12–22 hours</td>
</tr>
<tr>
<td class="product">BL-100SC</td>
</tr>
<tr>
<td class="product">BL-100H</td>
<td rowspan="2">Class S (≤0.1%)</td>
<td rowspan="2">PL3</td>
<td>99.97% or more</td>
<td rowspan="2">≤397g</td>
<td rowspan="2">Avg 222g</td>
<td rowspan="2">Approx. 9 hours</td>
<td rowspan="2">Approx. 10–18 hours</td>
</tr>
<tr>
<td class="product">BL-100U</td>
<td>99.99% or more</td>
</tr>
</tbody>
</table>
<div class="note">
<div>*1 Calculated duration for maintaining positive pressure inside the facepiece under standard indoor conditions.</div>
<div>*2 Observed duration for maintaining positive pressure in dusty environments, based on actual worker respiratory data during field work.</div>
<div>*3 May vary or be shorter depending on actual usage conditions.</div>
</div>
<h3>Replacement Filters and Optional Accessories</h3>
<table>
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56559" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_133302-removebg-preview.png" alt="" width="263" height="171" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56560" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_133247-removebg-preview.png" alt="" width="261" height="166" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56558" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_133314-removebg-preview.png" alt="" width="249" height="169" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56554" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-133324.png" alt="" width="228" height="169" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56555" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-133334.png" alt="" width="231" height="166" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56556" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-133347.png" alt="" width="299" height="119" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56557" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-133356.png" alt="" width="261" height="116" /></td>
</tr>
<tr>
<td height="19"><strong>Alpha Ring Filter BRD-8U</strong><br />
Screw-on / Twist-lock</td>
<td><strong>Alpha Ring Filter BRD-82</strong><br />
Screw-on / Twist-lock</td>
<td><strong>Alpha Ring Filter BRD-82U</strong><br />
Screw-on / Twist-lock</td>
<td><strong>Alpha Ring Filter BLA-62</strong></td>
<td><strong>Alpha Ring Filter BRD-7</strong></td>
<td><strong>Mighty Micron Filter For BL-7005</strong></td>
<td><strong>Mighty Micron Filter For BL-1005</strong></td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<td class="xl65" colspan="2" width="128" height="19">Optional: For Ozone / Organic odor removal (5 pcs/pack)</td>
</tr>
<tr>
<td height="19"><img loading="lazy" decoding="async" class="aligncenter wp-image-56561" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-134109.png" alt="" width="366" height="136" /></td>
<td><img loading="lazy" decoding="async" class=" wp-image-191670 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-768x323-1-300x139.png" alt="" width="319" height="148" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-768x323-1-300x139.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-768x323-1-1024x474.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-768x323-1-768x355.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-9-768x323-1.png 1500w" sizes="auto, (max-width: 319px) 100vw, 319px" /></td>
</tr>
<tr>
<td height="19">KBC Filter For BL-7005</td>
<td>KBC Filter For BL-1005</td>
</tr>
</tbody>
</table>
<p data-path-to-node="1,0,0">When performing tasks such as welding or grinding where sparks or spatter are generated, it is mandatory to use the dedicated inhalation port cover (sold separately) on the filter (except for BL-7005 and BL-1005 series). Note that the BL-700HA/U, BL-200H/U, and BL-100H/U series are not designed for use in environments with sparks or spatter.</p>
<h3 data-path-to-node="0">Key Features:</h3>
<ul>
<li data-path-to-node="1"><b data-path-to-node="1" data-index-in-node="0">High Synchro: </b>Next-generation model improves airflow efficiency and tracks user breathing rhythm more accurately.</li>
<li data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Fit Checker: </b>Easily perform a fit test by simply pulling the lever.</li>
<li data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Under Chin: </b>Unique curved design enhances the airtight seal at the face contact area.</li>
<li data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">Micron: </b>High-performance electrostatic filter. This respirator utilizes Micron filter technology.</li>
<li data-path-to-node="9"><b data-path-to-node="9" data-index-in-node="0">Speaker: </b>Integrated small communication speaker ensures clear dialogue while wearing the mask.</li>
<li data-path-to-node="11"><b data-path-to-node="11" data-index-in-node="0">Special Hard Coating: </b>Improved scratch resistance compared to standard surface hardening methods.</li>
<li data-path-to-node="12,0,0"><b data-path-to-node="14" data-index-in-node="0">Silicone: </b>The facepiece uses high-grade silicone material for a soft, skin-friendly fit.</li>
<li data-path-to-node="16"><b data-path-to-node="16" data-index-in-node="0">Speaking Diaphragm: </b>Facilitates clear communication and instruction without mask removal.</li>
<li data-path-to-node="18"><b data-path-to-node="18" data-index-in-node="0">Internal Pressure Monitoring: </b>Flashing light alerts the user when positive pressure is lost inside the facepiece.</li>
<li data-path-to-node="20"><b data-path-to-node="20" data-index-in-node="0">HAWC Lip: </b>Full-face models use the HAWC Lip structure for a high-seal &#8220;suction cup effect.&#8221;</li>
<li data-path-to-node="22"><b data-path-to-node="22" data-index-in-node="0">Hardened Eyepiece: </b>The visor surface is treated with a hardening process to resist scratches.</li>
</ul>The post <a href="https://koueitrading.com/global/product/koken-bl-321-series-p-papr/">Koken BL-321 Series P-PAPR</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken BL-351 Series P-PAPR</title>
		<link>https://koueitrading.com/global/product/koken-bl-351-series-p-papr/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Wed, 04 Mar 2020 06:58:51 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=191666</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: BL-351 Series P-PAPR: Powered Air-Purifying Particulate Respirator PARTICULATE PAPR and GAS PAPR PAPR: Powered Air-Purifying Respirator. P-PAPR: Particulate PAPR (Used for dust/particles). G-PAPR: Gas PAPR (Used for toxic gases/vapors). Within the PAPR range, there are “Powered Air-Purifying Particulate Respirators (P-PAPR)” for dust hazards and “Powered Air-Purifying Gas Respirators (G-PAPR)” for toxic [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-bl-351-series-p-papr/">Koken BL-351 Series P-PAPR</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: BL-351 Series</p>
<p>P-PAPR: Powered Air-Purifying Particulate Respirator</p>
<h2>PARTICULATE PAPR and GAS PAPR</h2>
<ul>
<li data-path-to-node="14,0,0">PAPR: Powered Air-Purifying Respirator.</li>
<li data-path-to-node="14,1,0">P-PAPR: Particulate PAPR (Used for dust/particles).</li>
<li data-path-to-node="14,2,0">G-PAPR: Gas PAPR (Used for toxic gases/vapors).</li>
</ul>
<p data-path-to-node="3">Within the PAPR range, there are “Powered Air-Purifying Particulate Respirators (P-PAPR)” for dust hazards and “Powered Air-Purifying Gas Respirators (G-PAPR)” for toxic gas hazards. It is essential to understand the properties, type, and concentration of the hazardous substances before selecting the appropriate mask.</p>
<p data-path-to-node="3">To prevent inhalation of DUST -&gt; Use a Powered Air-Purifying Particulate Respirator (P-PAPR)<br />
To prevent inhalation of TOXIC GAS -&gt; Use a Powered Air-Purifying Gas Respirator (G-PAPR)<br />
To prevent inhalation of MIXED DUST &amp; TOXIC GAS -&gt; Use a Powered Air-Purifying Gas Respirator (G-PAPR) with dust protection function</p>
<h3>Environments where PAPR CANNOT be used</h3>
<p data-path-to-node="9">PAPR must not be used if any of the following conditions apply. Please use respiratory protective equipment suitable for the environment, such as a supplied-air respirator or a self-contained breathing apparatus (SCBA).</p>
<ul>
<li data-path-to-node="10,0,0">Oxygen-deficient environments or those at risk of oxygen deficiency (Oxygen concentration below 18%).</li>
<li data-path-to-node="10,1,0">Cases where the type or concentration of the toxic gas is unknown.</li>
<li data-path-to-node="10,2,0">IDLH environments (Atmospheres Immediately Dangerous to Life or Health).</li>
<li data-path-to-node="10,2,0">Cases where the toxic gas concentration exceeds the permissible limit for the PAPR. ※</li>
<li data-path-to-node="10,3,0">Cases where no filter (canister) is available to remove the specific toxic gas in the environment.</li>
<li data-path-to-node="10,4,0">Cases where a mixture of gases with different properties exists.</li>
<li data-path-to-node="10,5,0">Cases where the environment deviates significantly from normal temperature, humidity, and atmospheric pressure.</li>
</ul>
<p data-path-to-node="11">(※ According to standards based on the Industrial Safety and Health Act, the application range of G-PAPR is 2% (3% for Ammonia))</p>
<h3>SELECTING THE APPROPRIATE PAPR BASED ON HAZARD CONCENTRATION</h3>
<p data-path-to-node="3">Determine the Required Protection Factor, then select a PAPR model with an Assigned Protection Factor higher than that value.</p>
<p data-path-to-node="4,0">Formula: How to calculate the Required Protection Factor<br />
<strong>Required Protection Factor = Ambient concentration of identified hazard / Permissible exposure limit of the hazard</strong></p>
<p>Assigned Protection Factor of P-PAPR</p>
<table>
<thead>
<tr>
<th colspan="2"><strong>Classification</strong></th>
<th colspan="4"><strong>Facepiece Type</strong></th>
</tr>
<tr>
<th><strong>Leakage Rate</strong></th>
<th><strong>Filter Efficiency</strong></th>
<th><strong>Half-face</strong></th>
<th><strong>Full-face</strong></th>
<th><strong>Hood Type</strong></th>
<th><strong>Face shield</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td rowspan="3">Class S</td>
<td>PL3/PS3</td>
<td>50/300</td>
<td>1000</td>
<td>25/1000</td>
<td>25/300</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>—</td>
<td>—</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td rowspan="3">Class A</td>
<td>PL3/PS3</td>
<td>—</td>
<td>—</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>33</td>
<td>90</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>14</td>
<td>19</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td rowspan="3">Class B</td>
<td>PL3/PS3</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>14</td>
<td>19</td>
<td>11</td>
<td>11</td>
</tr>
</tbody>
</table>
<p>Assigned Protection Factor of G-PAPR</p>
<table>
<thead>
<tr>
<th class="header-main" colspan="4"><strong>Facepiece Type</strong></th>
</tr>
<tr>
<th><strong>Half-face</strong></th>
<th><strong>Full-face</strong></th>
<th><strong>Hood Type</strong></th>
<th><strong>Face shield</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>50/300</td>
<td>1000</td>
<td>25/1000</td>
<td>25/300</td>
</tr>
</tbody>
</table>
<p>For “G-PAPR with dust protection function,” please refer to the Assigned Protection Factor of P-PAPR (Class S leakage rate) mentioned above for dust (and similar particulates).</p>
<h2>TASKS WHERE PAPR USE IS MANDATORY BY REGULATION OR DIRECTIVE</h2>
<p><strong>For tasks where PAPR use is mandatory by regulation or directive, please use a PAPR with the designated performance classification.</strong></p>
<h4><strong>1. Tunnel Construction Work</strong></h4>
<p><strong>Regulation:</strong> “Ordinance on Prevention of Pneumoconiosis”<br />
<strong>Scope:</strong> In tunnel construction, at locations involving “mechanical/powered excavation,” “mechanical loading or unloading of ore/rock,” and “shotcreting.”</p>
<p><strong>PAPR Requirements:</strong></p>
<ul>
<li>National test certified product (High airflow type).</li>
<li>Tight-fitting facepiece type where the battery can be removed for use during blasting operations.</li>
</ul>
<h4><strong>2. Asbestos Removal Work</strong></h4>
<p><strong>Regulation:</strong> “Ordinance on Prevention of Health Impairment due to Asbestos”<br />
<strong>Scope</strong>: In asbestos removal tasks, specifically those requiring “Class 1 Asbestos Removal Masks.”<br />
<b data-path-to-node="11,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified tight-fitting or hood types (High airflow, Class S, PL3 or PS3).</p>
<h4 data-path-to-node="12"><b data-path-to-node="12" data-index-in-node="0">3. Handling Nanomaterials</b></h4>
<p data-path-to-node="13,0,0"><b data-path-to-node="13,0,0" data-index-in-node="0">Directive:</b> “Regarding Preventive Measures for Exposure to Nanomaterials”<br />
<b data-path-to-node="13,1,0" data-index-in-node="0">Scope:</b> Manufacturing and handling of nanomaterials. (※)<br />
<b data-path-to-node="13,2,0" data-index-in-node="0">PAPR Requirements:</b></p>
<ul>
<li data-path-to-node="13,2,0">National test certified product (High airflow, PL3 or PS3).</li>
<li data-path-to-node="13,2,1,0,0">Shape limitations based on the projected exposure levels of workers.</li>
</ul>
<p data-path-to-node="13,2,1,1,0">(※) Depending on the work environment, respiratory protective equipment other than PAPR may be used.</p>
<h4 data-path-to-node="14"><b data-path-to-node="14" data-index-in-node="0">4. Handling Indium</b></h4>
<p data-path-to-node="15,0,0"><b data-path-to-node="15,0,0" data-index-in-node="0">Directive:</b> “Regarding Thorough Health Hazard Prevention Measures for Indium/Tin Oxide Handling”<br />
<b data-path-to-node="15,1,0" data-index-in-node="0">Scope:</b> Handling of Indium, Tin Oxide, etc. (※)<br />
<b data-path-to-node="15,2,0" data-index-in-node="0">PAPR Requirements:</b></p>
<ul>
<li data-path-to-node="15,2,0">National test certified product (High airflow, PL3 or PS3).</li>
<li data-path-to-node="15,2,1,0,0">Limitations on shape and leakage rate based on working environment measurement results.</li>
</ul>
<p data-path-to-node="15,2,1,1,0">(※) Depending on environmental results, respiratory protective equipment other than PAPR may be used.</p>
<h4 data-path-to-node="16"><b data-path-to-node="16" data-index-in-node="0">5. Handling Dioxins</b></h4>
<p><b data-path-to-node="17,0,0" data-index-in-node="0">Directive:</b> “Revision of Guidelines for Dioxin Exposure Prevention in Waste Incineration Facilities”<br />
<b data-path-to-node="17,1,0" data-index-in-node="0">Scope:</b> For dioxin-exposure risk tasks classified as “Level 1.” (※)<br />
<b data-path-to-node="17,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified product (High airflow, PL3 or PS3).</p>
<p>(※) RL3 or RS3 dust masks may be used, but PAPR with higher protective performance is recommended.</p>
<h4 data-path-to-node="18"><b data-path-to-node="18" data-index-in-node="0">6. Handling Refractory Ceramic Fibers (RCF)</b></h4>
<p><b data-path-to-node="19,0,0" data-index-in-node="0">Regulation:</b> “Ordinance on Prevention of Hazards due to Specified Chemical Substances”<br />
<b data-path-to-node="19,1,0" data-index-in-node="0">Scope:</b> Insulation or fireproofing work involving the application of RCF to furnaces or boilers; or repair, dismantling, and demolition of such furnaces/boilers.<br />
<b data-path-to-node="19,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified product (PL3 or PS3).</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong>PAPR Standards</strong></th>
<td width="64">Beyond JIS standards, Powered Air-Purifying Respirators must adhere to standards defined under the Industrial Safety and Health Act. These comprehensive standards ensure that products are manufactured under strict safety requirements.</td>
</tr>
</tbody>
</table>
<p>The following table is excerpted from the ‘Standards for Powered Air-Purifying Respirators’</p>
<h3>Types of Powered Air-Purifying Respirators</h3>
<table>
<tbody>
<tr>
<th colspan="2"><strong>Powered Air-Purifying Particulate Respirator (P-PAPR)</strong></th>
</tr>
<tr>
<th rowspan="2"><strong>Powered Air-Purifying Gas Respirator (G-PAPR)</strong></th>
<td>Type with dust protection function</td>
</tr>
<tr>
<td>Type without dust protection function</td>
</tr>
</tbody>
</table>
<p><strong>■ Classification by Shape</strong></p>
<table>
<tbody>
<tr>
<th rowspan="2"><strong>Tight-fitting Facepiece</strong><br />
<span class="sub-item">・Full-face</span><br />
<span class="sub-item">・Half-face</span></th>
<td>Isolation type (with hose)</td>
</tr>
<tr>
<td>Direct connection type</td>
</tr>
<tr>
<th rowspan="2"><strong>Loose-fitting Facepiece</strong><br />
<span class="sub-item">・Hood</span><br />
<span class="sub-item">・Face shield</span></th>
<td>Isolation type (with hose)</td>
</tr>
<tr>
<td>Direct connection type</td>
</tr>
</tbody>
</table>
<p><strong>■ Classification by Performance</strong></p>
<table>
<thead>
<tr>
<th><strong>Airflow Performance Classification</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>Standard airflow type</td>
</tr>
<tr>
<td>High airflow type</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th><strong>Leakage Rate Performance Classification (P-PAPR)</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>Class B</td>
</tr>
<tr>
<td>Class A</td>
</tr>
<tr>
<td>Class S</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th colspan="2"><strong>Filter Material Performance Classification<br />
(P-PAPR and G-PAPR with dust function)</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td width="50%">PS1</td>
<td width="50%">PL1</td>
</tr>
<tr>
<td>PS2</td>
<td>PL2</td>
</tr>
<tr>
<td>PS3</td>
<td>PL3</td>
</tr>
</tbody>
</table>
<h3>Performance Testing for Powered Air-Purifying Respirators</h3>
<h4><strong>■ Particle Collection Efficiency Test</strong></h4>
<p>(Applies only to P-PAPR and G-PAPR with dust protection)</p>
<table>
<tbody>
<tr>
<th class="header-bg col-label" rowspan="3"><strong>Test Particle</strong></th>
<th class="header-bg col-sub"><strong>Type</strong></th>
<td class="align-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="align-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="header-bg"><strong>Particle Size</strong></th>
<td colspan="2">0.06μm ~ 0.1μm</td>
<td colspan="2">0.15μm ~ 0.25μm</td>
</tr>
<tr>
<th class="header-bg"><strong>Concentration</strong></th>
<td colspan="2">50mg/m³ or less</td>
<td colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="header-bg" rowspan="2"><strong>Test Flow Rate</strong></th>
<th class="header-bg"><strong>Standard Flow</strong></th>
<td colspan="4">104 L/min</td>
</tr>
<tr>
<th class="header-bg"><strong>High Flow</strong></th>
<td colspan="4">138 L/min</td>
</tr>
<tr>
<th class="header-bg align-left" colspan="2" rowspan="4"><strong>Collection Efficiency<br />
(Continuous measurement; must meet values in the right column)</strong></th>
<td colspan="2">For NaCl, loaded up to 200mg</td>
<td colspan="2">For DOP, loaded up to 400mg</td>
</tr>
<tr>
<td class="col-val">PS1</td>
<td class="col-res">95.0% or more</td>
<td class="col-val">PL1</td>
<td class="col-res">95.0% or more</td>
</tr>
<tr>
<td>PS2</td>
<td>99.0% or more</td>
<td>PL2</td>
<td>99.0% or more</td>
</tr>
<tr>
<td>PS3</td>
<td>99.97% or more</td>
<td>PL3</td>
<td>99.97% or more</td>
</tr>
</tbody>
</table>
<h4><strong>■ Canister Testing</strong></h4>
<p>(Applies only to G-PAPR)</p>
<table>
<tbody>
<tr>
<th><strong>Airtightness</strong></th>
<td class="align-left" colspan="4">No air leakage at 1470 Pa pressure</td>
</tr>
<tr>
<th rowspan="5"><strong>Decontamination Capacity<br />
(Time until breakthrough at specified concentration must be ≥ the right column)</strong></th>
<th><strong>Type</strong></th>
<th><strong>Test Gas</strong></th>
<th><strong>Breakthrough Concentration</strong></th>
<th><strong>Duration</strong></th>
</tr>
<tr>
<td>Halogen gas</td>
<td>Chlorine (0.02%)</td>
<td>1 ppm</td>
<td>40 mins or more</td>
</tr>
<tr>
<td>Organic gas</td>
<td>Cyclohexane (0.03%)</td>
<td>5 ppm</td>
<td>50 mins or more</td>
</tr>
<tr>
<td>Ammonia</td>
<td>Ammonia (0.1%)</td>
<td>50 ppm</td>
<td>40 mins or more</td>
</tr>
<tr>
<td>SO₂ gas</td>
<td>Sulfur dioxide (0.03%)</td>
<td>5 ppm</td>
<td>35 mins or more</td>
</tr>
<tr>
<th><strong>Leakage Concentration</strong></th>
<td class="align-left" colspan="4">At maximum flow rate, time to reach breakthrough must be ≥ 3 minutes.</td>
</tr>
</tbody>
</table>
<h4><strong>■ Inward Leakage Rate Test</strong></h4>
<table>
<colgroup>
<col />
<col />
<col />
<col /></colgroup>
<tbody>
<tr>
<th rowspan="3"><strong>Test Particle</strong></th>
<th><strong>Type</strong></th>
<td colspan="4">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<th><strong>Particle Size</strong></th>
<td colspan="4">0.06μm ~ 0.2μm</td>
</tr>
<tr>
<th><strong>Concentration</strong></th>
<td colspan="4">18mg/m³ or less</td>
</tr>
<tr>
<th rowspan="4"><strong>Simulated Breathing</strong></th>
<th><strong>Type</strong></th>
<td colspan="2">Standard Flow</td>
<td colspan="2">High Flow</td>
</tr>
<tr>
<th><strong>Waveform</strong></th>
<td colspan="4">Sine wave</td>
</tr>
<tr>
<th><strong>Ventilation Volume</strong></th>
<td colspan="2">1.5 ± 0.075 L/stroke</td>
<td colspan="2">1.6 ± 0.08 L/stroke</td>
</tr>
<tr>
<th><strong>Frequency</strong></th>
<td colspan="2">20 times/min</td>
<td colspan="2">25 times/min</td>
</tr>
<tr>
<th colspan="2" rowspan="4"><strong>Leakage Rate<br />
(2-minute continuous measurement; max value must meet the right column)</strong></th>
<td rowspan="3">P-PAPR</td>
<td>Class B</td>
<td colspan="2">5.0% or less</td>
</tr>
<tr>
<td>Class A</td>
<td colspan="2">1.0% or less</td>
</tr>
<tr>
<td>Class S</td>
<td colspan="2">0.1% or less</td>
</tr>
<tr>
<td>G-PAPR</td>
<td colspan="3">0.1% or less</td>
</tr>
<tr>
<th colspan="2" rowspan="4"><strong>Headform Movement<br />
(Calculate leakage rate for each item)</strong></th>
<th colspan="3"><strong>Position and Range</strong></th>
<th><strong>Frequency</strong></th>
</tr>
<tr>
<td rowspan="2">Head</td>
<td colspan="2">Front/Back 30 degrees</td>
<td>17 times/min</td>
</tr>
<tr>
<td colspan="2">Left/Right rotation 50 degrees</td>
<td>11 times/min</td>
</tr>
<tr>
<td>Arms</td>
<td colspan="2">Raising 10 ~ 130 degrees</td>
<td>7 times/min</td>
</tr>
</tbody>
</table>
<h4><strong>■ Other Tests</strong></h4>
<table>
<tbody>
<tr>
<th><strong>Internal Pressure<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">Under simulated breathing identical to the leakage test:<br />
0 Pa &lt; Internal Mask Pressure &lt; 400 Pa</td>
</tr>
<tr>
<th rowspan="2"><strong>Minimum Required Flow<br />
(Loose-fit only)</strong></th>
<td class="align-center">Standard Flow</td>
<td class="align-center">104 L/min or more</td>
</tr>
<tr>
<td class="align-center">High Flow</td>
<td class="align-center">138 L/min or more</td>
</tr>
<tr>
<th><strong>Inhalation Resistance<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">160 Pa or less<br />
(40 L/min flow rate, fan OFF)</td>
</tr>
<tr>
<th><strong>Exhalation Resistance<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">80 Pa or less<br />
(40 L/min flow rate, fan OFF)</td>
</tr>
<tr>
<th><strong>Exhalation Valve Airtightness<br />
(Tight-fitting only)</strong></th>
<td class="content-cell" colspan="2">・Internal pressure must drop immediately when air is sucked.<br />
・Time for pressure to return to normal must be ≥ 15 seconds.</td>
</tr>
<tr>
<th><strong>CO2 Concentration Increase<br />
(Tight-fitting only)</strong></th>
<td class="content-cell" colspan="2">With fan OFF, headform breathes CO2 air. Difference between wearing and not wearing mask must be &lt; 2.0%.</td>
</tr>
<tr>
<th><strong>Noise Level</strong></th>
<td class="align-center" colspan="2">Noise at the headform ear area must be below 80 dB (both sides).</td>
</tr>
<tr>
<th rowspan="4"><strong>Flow Rate<br />
(G-PAPR only)</strong></th>
<td>Max set average flow</td>
<td class="content-cell">Average must be ≤ the decontamination test flow rate.</td>
</tr>
<tr>
<td>Maximum flow</td>
<td class="content-cell">Maximum must be ≤ the flow rate set by the manufacturer.</td>
</tr>
<tr>
<th><strong>Tight-fitting type</strong></th>
<th><strong>Loose-fitting type</strong></th>
</tr>
<tr>
<td class="content-cell">Measure resistance with fan OFF/ON at 20~170 L/min to calculate flow per minute.</td>
<td class="content-cell">With fan ON, draw air for 5 mins to maintain normal pressure in chamber, then measure flow.</td>
</tr>
</tbody>
</table>
<h2>PAPR USE IS ENCOURAGED IN THE 10TH COMPREHENSIVE DUST HAZARD COUNTERMEASURES</h2>
<p><strong>To reduce pneumoconiosis, dust prevention measures must be strengthened.</strong></p>
<p>The “10th Comprehensive Countermeasures for Preventing Dust Hazards” demands the correct use of effective respiratory protection against dust exposure across all industries. PAPR is highlighted as a “more effective preventive measure for health impairment,” and its adoption is highly encouraged.<br />
The use of PAPR is more effective in preventing health impairment compared to standard dust masks due to its higher protection factor and reduced physical strain on the wearer.<br />
(Partial excerpt from the 10th Comprehensive Countermeasures)</p>
<p>Furthermore, due to high performance, PAPR is mandatory for specific tasks, but its use is also recommended for tasks outside the mandatory categories.<br />
While PAPR is mandatory for specific operations under the Dust Rules, its high performance makes it desirable for other tasks; thus, guidance and inspections encourage businesses to adopt PAPR for their workers.<br />
(Partial excerpt from the 10th Comprehensive Countermeasures)</p>
<h2>KOKEN BL SERIES BREATH-RESPONSIVE PAPR</h2>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Achieving “High Safety” and “Comfortable Fit” as expected</b></p>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">THE EVOLUTION OF THE BL SERIES</b></p>
<p data-path-to-node="6">The BL Series continues to evolve into the PAPR model that helps perfect safety and health management in every field, aligning with occupational health trends and market expansion.</p>
<p data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">CORE DEVELOPMENT FOCUS</b></p>
<ul>
<li data-path-to-node="8,0,0"><b data-path-to-node="8,0,0" data-index-in-node="0">“Safety”:</b> Improving the protection capability as a respirator.</li>
<li data-path-to-node="8,1,0"><b data-path-to-node="8,1,0" data-index-in-node="0">“Flow Technology”:</b> Minimizing waste and improving efficiency.</li>
<li data-path-to-node="8,2,0"><b data-path-to-node="8,2,0" data-index-in-node="0">“Lightweight Design”:</b> Reducing the burden on the worker.</li>
</ul>
<h2>KOKEN FLOW TECHNOLOGY: New BSFS air flow highly synchronized with breathing</h2>
<h3>THE MECHANISM OF THE BSFS (BREATH SYNCHRONIZED) SYSTEM</h3>
<p data-path-to-node="5">The BL Series is equipped with the Breath Synchronized-Air Flow System (new BSFS), which delivers airflow that follows the breathing rhythm more closely than ever, becoming a “Highly Synchronized” model.<br />
BSFS ELIMINATES THE FEELING OF BREATHLESSNESS/STUFFINESS<br />
<img loading="lazy" decoding="async" class="size-medium wp-image-191639 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-300x177.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-300x177.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4.jpg 464w" alt="" width="300" height="177" /></p>
<p><b data-path-to-node="2" data-index-in-node="0">THE BSFS MECHANISM HAS EVOLVED INTO “HIGH SYNCHRONIZATION”</b></p>
<p data-path-to-node="3">Using a fan equipped with a breath detection sensor, the device supplies “the necessary and sufficient amount of air” corresponding to the user’s inhalation. Responsiveness to breathing has been improved, and the accuracy of synchronization with the respiratory rhythm has significantly increased.<br />
<img loading="lazy" decoding="async" class="size-medium wp-image-191638 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-300x286.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-300x286.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-768x733.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1.jpg 1024w" alt="" width="300" height="286" /></p>
<h3>COMFORT UP</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">SOLVING MASK DISCOMFORT WITH FLOW THAT FOLLOWS EVERY BREATH</b></p>
<ul>
<li data-path-to-node="4,0,0">Reduces the physical workload for laborers.</li>
<li data-path-to-node="4,1,0">Solves breathing difficulties and stuffiness in high-temperature workplaces.</li>
</ul>
<h3>SAFETY UP</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">PREVENTING INWARD LEAKAGE THROUGH HIGH PROTECTION AND CONSTANT POSITIVE PRESSURE</b></p>
<p data-path-to-node="4,0,0">Breath Synchronization: Protection is guaranteed by the blower linked to breathing.</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class=" wp-image-191633 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-300x227.jpg" sizes="auto, (max-width: 441px) 100vw, 441px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-300x227.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-768x581.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6.jpg 1024w" alt="" width="441" height="334" /></td>
<td width="64"><img loading="lazy" decoding="async" class=" wp-image-191636 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-300x218.png" sizes="auto, (max-width: 508px) 100vw, 508px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-300x218.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-1024x745.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-768x559.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185.png 1407w" alt="" width="508" height="369" /></td>
</tr>
<tr>
<td height="19">
<p data-path-to-node="3,0,0"><b data-path-to-node="3,0,0" data-index-in-node="0">DURING INHALATION:</b> Air inside the mask is normally sucked away, but supplemental airflow prevents negative pressure. (If a gap exists, air blows outward ※1)</p>
<p data-path-to-node="3,0,0">※1: Airflow varies based on facepiece fit.</p>
</td>
<td>
<p data-path-to-node="3,1,0"><b data-path-to-node="3,1,0" data-index-in-node="0">DURING EXHALATION:</b> Since pressure doesn’t drop, airflow is reduced. This conserves the “filter” and “battery.”</p>
<p data-path-to-node="3,1,0">※2: Flow doesn’t stop completely (maintains a small amount for safety).</p>
</td>
</tr>
</tbody>
</table>
<p><b data-path-to-node="2" data-index-in-node="0">PAPR AVOIDS HIGH LEAKAGE RISKS FROM DUST BUILDUP IN LOOSE MASKS</b></p>
<p data-path-to-node="3">FOR CONVENTIONAL DUST MASKS:</p>
<p data-path-to-node="4">As dust builds on the filter, inhalation resistance increases, raising the risk of inward leakage. As dust accumulates, even if the gap remains the same, the leakage rate can double. (See diagram below)</p>
<p><img loading="lazy" decoding="async" class=" wp-image-191632 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-300x195.jpg" sizes="auto, (max-width: 409px) 100vw, 409px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-300x195.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-768x500.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-180x118.jpg 180w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8.jpg 1024w" alt="" width="409" height="266" /></p>
<p><b data-path-to-node="7" data-index-in-node="0">Leakage Measurement Method:</b> A 2.5% gap is created intentionally; NaCl concentration is measured inside/outside the mask with a digital meter.</p>
<h3>ECONOMY UP (ECO)</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">ELIMINATING WASTE THROUGH AN ECO FLOW MECHANISM</b></p>
<p data-path-to-node="4,0,0">Limits “wasteful dust buildup” and reduces filter usage: Minimizes air loss to reduce clogging.<br />
Limits battery usage: Extends runtime by reducing power consumption during low-respiration phases.</p>
<p><b data-path-to-node="2" data-index-in-node="0">BATTERY RUNTIME COMPARISON: NEW VS OLD BSFS</b></p>
<p data-path-to-node="3"><img loading="lazy" decoding="async" class=" wp-image-191631 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/1-300x126.png" sizes="auto, (max-width: 445px) 100vw, 445px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/1-300x126.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-1024x429.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-768x322.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/1.png 1536w" alt="" width="445" height="187" /></p>
<p data-path-to-node="3"><strong>ECO FLOW CREATED BY HIGH SYNCHRONIZATION</strong></p>
<p data-path-to-node="3"><img loading="lazy" decoding="async" class=" wp-image-191630 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/2-300x175.png" sizes="auto, (max-width: 456px) 100vw, 456px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/2-300x175.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-1024x599.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-768x449.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/2.png 1536w" alt="" width="456" height="266" />Image of BSFS flow following actual respiratory waveforms with high precision.</p>
<h2 data-path-to-node="3">KOKEN LIGHTWEIGHT DESIGN: Reducing burden for long shifts</h2>
<p>The “BL Series” optimizes compact sizing and weight equivalent to conventional dust masks. It is highly rated in tunnel construction, asbestos handling, and arc welding.</p>
<p><b data-path-to-node="4" data-index-in-node="0">SEPARATE TYPE</b> Because a direct-mounted battery adds weight to the neck, the separate design reduces perceived weight. This ultra-lightweight design minimizes mask body thickness.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56541" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-122956.png" alt="" width="348" height="302" /></p>
<p><b data-path-to-node="5" data-index-in-node="0">BUILT-IN TYPE</b> Thanks to “High Synchro” BSFS reducing power draw, battery size has been shrunk. This results in a lightweight built-in battery design with minimal burden.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56542" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123026.png" alt="" width="212" height="269" /></p>
<h2>KOKEN SAFETY DESIGN: Internal pressure monitoring to maintain positive pressure</h2>
<p data-path-to-node="3">(Common for BL-321/BL-351/BL-351X/BL-711/BL-700/BL-200/BL-100 series)</p>
<p data-path-to-node="4">Modern worksites require PAPRs that “constantly monitor internal pressure and provide alerts.”<br />
PAPR is most protective under positive pressure; therefore, the moment positive pressure cannot be maintained is the filter replacement time. “Internal monitoring” notifies the user when pressure drops due to weak flow.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56543" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123245.png" alt="" width="243" height="253" /></p>
<p data-path-to-node="7,0,0">■ Positive pressure inside the mask can be maintained through timely/appropriate filter replacement.<br />
■ Clarifies the standard for filter replacement – which is otherwise often vague or based on subjective estimation.<br />
■ Full airflow can be restored through proper battery charging.</p>
<p><b data-path-to-node="2" data-index-in-node="0">NOTIFICATION VIA AIRFLOW</b></p>
<p data-path-to-node="3">(For BL-321 / BL-351 / BL-351X / BL-711 series)</p>
<ul>
<li data-path-to-node="4,0,0">Pressure drop warning via “Continuous Airflow”: ➔ Replace the filter.</li>
<li data-path-to-node="4,1,0">Low battery warning via “Rhythmic Airflow”: ➔ Replace with a charged battery.</li>
</ul>
<p><b data-path-to-node="6" data-index-in-node="0">LED NOTIFICATION</b></p>
<p data-path-to-node="7">(For BL-700 / BL-200 / BL-100 series)</p>
<ul>
<li data-path-to-node="8,0,0">Pressure drop warning via “Flashing LED”: ➔ Replace the filter.</li>
<li data-path-to-node="8,1,0">Low battery warning via “Steady LED”: ➔ Replace with a charged battery.</li>
</ul>
<p><img loading="lazy" decoding="async" class=" wp-image-191629 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/3-300x65.png" sizes="auto, (max-width: 471px) 100vw, 471px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/3-300x65.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-1024x221.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-768x166.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/3.png 1536w" alt="" width="471" height="102" /></p>
<h2>POWERED AIR-PURIFYING PARTICULATE RESPIRATOR (P-PAPR)</h2>
<h3>BL-351 SERIES</h3>
<p data-path-to-node="2"><strong>High-duration model, effective for tasks with high dust concentrations</strong></p>
<p data-path-to-node="4,0,0"><b data-path-to-node="4,0,0" data-index-in-node="0">Classification:</b> <b data-path-to-node="4,0,0" data-index-in-node="11">STANDARD FLOW TYPE</b></p>
<p data-path-to-node="4"><b data-path-to-node="4" data-index-in-node="0">Key Features:</b></p>
<ul>
<li data-path-to-node="5,0,0">High Synchro</li>
<li data-path-to-node="5,1,0">Under Chin Design</li>
<li data-path-to-node="5,2,0">Silicone Material</li>
<li data-path-to-node="5,3,0">Speaking Diaphragm</li>
</ul>
<p data-path-to-node="1,0,0">■ High water resistance (IP55 rating) prevents moisture ingress.<br />
■ Integrated &#8220;Speaking Diaphragm&#8221; for clear communication.<br />
■ &#8220;Auto ON/OFF&#8221; function: Fan starts automatically upon inhalation.<br />
■ Low battery warning via &#8220;Airflow Notification.&#8221;</p>
<h4 data-path-to-node="1"><b data-path-to-node="1" data-index-in-node="0">BL-351S, BL-351H, BL-351U</b></h4>
<p data-path-to-node="2"><b data-path-to-node="2" data-index-in-node="0">Shared Facepiece Body (※1)<br />
</b><b data-path-to-node="3,0,0" data-index-in-node="0">Versatile use by switching filters based on specific application.</b></p>
<ul>
<li data-path-to-node="3,0,1,0,0">Install BLA-62 for BL-351S configuration</li>
<li data-path-to-node="3,0,1,1,0">Install BRD-82 for BL-351H configuration</li>
<li data-path-to-node="3,0,1,2,0">Install BRD-82U for BL-351U configuration</li>
</ul>
<h3><b data-path-to-node="1" data-index-in-node="0">Sakai Type</b> <b data-path-to-node="1" data-index-in-node="11">BL-351S-04</b></h3>
<p>Includes battery &amp; charger. Pattern Test Cert TP152<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56587" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_154027-removebg-preview.png" alt="" width="169" height="206" /></p>
<ul>
<li data-path-to-node="2,0,0">PL1 efficiency</li>
<li data-path-to-node="2,1,0">Class B leakage</li>
<li data-path-to-node="2,2,0">Assigned Protection Factor: 14</li>
</ul>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Applications:</b></p>
<ul>
<li data-path-to-node="4,0,0">General Dust</li>
<li data-path-to-node="4,1,0">Tunnel Construction Work</li>
</ul>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Replacement Filter: </b>Alpha Ring Filter BLA-62</p>
<p data-path-to-node="5"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56588" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-154154.png" alt="" width="116" height="145" /></p>
<p data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">Note: </b>BL-351S includes &#8220;BL Cover Type 2&#8221; to prevent dust accumulation.</p>
<h3><b data-path-to-node="7" data-index-in-node="0">Sakai Type</b> <b data-path-to-node="1" data-index-in-node="11">BL-351H-04</b></h3>
<p>Includes battery &amp; charger. Pattern Test Cert TP151<br />
<img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56589" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_154235-removebg-preview.png" alt="" width="185" height="198" /></p>
<ul>
<li data-path-to-node="2,0,0">PL3 efficiency</li>
<li data-path-to-node="2,1,0">Class S leakage</li>
<li data-path-to-node="2,2,0">Assigned Protection Factor: 300 (※2)</li>
</ul>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Applications:</b></p>
<ul>
<li data-path-to-node="4,0,0">Asbestos removal</li>
<li data-path-to-node="4,1,0">Indium handling</li>
<li data-path-to-node="4,2,0">RCF (Refractory Ceramic Fiber) handling</li>
<li data-path-to-node="4,3,0">Dioxin (Level 1)</li>
<li data-path-to-node="4,4,0">Tunnel construction</li>
</ul>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Replacement Filter: </b>Alpha Ring Filter BRD-82</p>
<h3><b data-path-to-node="5" data-index-in-node="0">Sakai Type </b><b data-path-to-node="1" data-index-in-node="11">BL-351U-04</b></h3>
<p>Includes battery &amp; charger. Pattern Test Cert TP153<br />
<img loading="lazy" decoding="async" class="size-medium wp-image-191667 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/4-1-300x200.png" alt="" width="300" height="200" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/4-1-300x200.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/4-1-1024x683.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/4-1-768x512.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/4-1.png 1536w" sizes="auto, (max-width: 300px) 100vw, 300px" /></p>
<ul>
<li data-path-to-node="2,0,0">PL3 efficiency</li>
<li data-path-to-node="2,1,0">Class S leakage</li>
<li data-path-to-node="2,2,0">Assigned Protection Factor: 300 (※2)</li>
</ul>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Applications: </b>Nanomaterial handling</p>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Replacement Filter: </b>Alpha Ring Filter BRD-82U</p>
<h3><b data-path-to-node="1" data-index-in-node="0">Sakai Type</b> <b data-path-to-node="2" data-index-in-node="0">BL-351HX-04</b></h3>
<p>Includes battery &amp; charger. Pattern Test Cert TP154</p>
<h4 data-path-to-node="1"><b data-path-to-node="1" data-index-in-node="0">BL351HX</b></h4>
<p data-path-to-node="2">Standard facepiece body.<br />
Compatible with G-PAPR (Gas-PAPR) by installing the appropriate gas canister.</p>
<h4 data-path-to-node="1"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56591" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-155057.png" alt="" width="175" height="202" /></h4>
<ul>
<li data-path-to-node="3,0,0">PL3 efficiency</li>
<li data-path-to-node="3,1,0">Class S leakage</li>
<li data-path-to-node="3,2,0">Assigned Protection Factor: 300 (※2)</li>
</ul>
<p data-path-to-node="4"><b data-path-to-node="4" data-index-in-node="0">Applications:</b></p>
<ul>
<li data-path-to-node="5,0,0">Asbestos removal</li>
<li data-path-to-node="5,1,0">Indium handling</li>
<li data-path-to-node="5,2,0">RCF handling</li>
<li data-path-to-node="5,3,0">Dioxin (Level 1)</li>
</ul>
<p data-path-to-node="6"><b data-path-to-node="6" data-index-in-node="0">Replacement Filter: </b>Alpha Ring Filter BRD-82</p>
<p data-path-to-node="1,0,0"><strong>※1</strong> BL-351HX uses a non-shared facepiece body.<br />
<strong>※2</strong> Based on Simulated Workplace Protection Factor (SWPF) measurements conducted by our company, proving the protection factor exceeds 300.</p>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56592" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-155327.png" alt="" width="109" height="111" /></td>
<td style="width: 48pt;" width="64">
<p data-path-to-node="1"><b data-path-to-node="1" data-index-in-node="0">Water Ingress Protection (※1), High Waterproofing</b></p>
<p data-path-to-node="2">Enhanced waterproof performance essential for worksites, equivalent to IP55 rating (※2). Designed to protect against water spray from any direction. Suitable for sudden rain or tasks involving water spraying.</p>
<p data-path-to-node="3,0,0"><b data-path-to-node="3,0,0" data-index-in-node="0">(※1)</b> Waterproofing is not guaranteed under all usage conditions.<br />
<b data-path-to-node="3,1,0" data-index-in-node="0">(※2)</b> Compliant with JIS C 0920 standards for Degree of protection provided by enclosures (IP Code).</p>
</td>
</tr>
</tbody>
</table>
<p data-path-to-node="1,0,0"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56593" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-155505.png" alt="" width="197" height="143" /></p>
<p data-path-to-node="1"><b data-path-to-node="1" data-index-in-node="0">Compatible Series:</b></p>
<ul>
<li data-path-to-node="2,0,0">BL-321 Series</li>
<li data-path-to-node="2,1,0">BL-351 Series</li>
<li data-path-to-node="2,2,0">BL-351X Series</li>
</ul>
<h3>Performance Specifications</h3>
<table class="spec-table">
<thead>
<tr>
<th rowspan="2"><strong>Product Name</strong></th>
<th colspan="3"><strong>Classification</strong></th>
<th rowspan="2"><strong>Collection Efficiency</strong></th>
<th rowspan="2"><strong>Weight (incl. battery)</strong></th>
<th rowspan="2"><strong>Facepiece Weight</strong></th>
<th rowspan="2"><strong>Battery Specs</strong></th>
<th rowspan="2"><strong>Nominal Runtime*1</strong></th>
<th rowspan="2"><strong>Actual Runtime*2</strong></th>
<th rowspan="2"><strong>Fan Lifespan</strong></th>
</tr>
<tr>
<th><strong>Fan Type</strong></th>
<th><strong>Leakage Rate</strong></th>
<th><strong>Filter Grade</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td class="product">BL-711H</td>
<td rowspan="4">High Airflow</td>
<td rowspan="4">Class S (≤0.1%)</td>
<td rowspan="4">PL3</td>
<td>99.97% or more</td>
<td colspan="2">≤753g (Avg 723g)</td>
<td class="left" rowspan="4">Li-ion Rechargeable<br />
Voltage: 7.2V<br />
Capacity: 2000mAh<br />
Charging: ~3 hours*3<br />
Cycles: ~300 times*3</td>
<td rowspan="2">Approx. 6 hours</td>
<td rowspan="2">Approx. 6.5–10 hours</td>
<td rowspan="20">Approx. 2,000 hours*3</td>
</tr>
<tr>
<td class="product">BL-711U</td>
<td>99.99% or more</td>
<td colspan="2">≤753g (Avg 720g)</td>
</tr>
<tr>
<td class="product">BL-700HA</td>
<td>99.97% or more</td>
<td rowspan="2">≤774g</td>
<td rowspan="2">Avg 591g</td>
<td rowspan="2">Approx. 7.5 hours</td>
<td rowspan="2">Approx. 8–14.5 hours</td>
</tr>
<tr>
<td class="product">BL-700U</td>
<td>99.99% or more</td>
</tr>
<tr>
<td class="product">BL-7005/AL</td>
<td rowspan="3">Standard Airflow</td>
<td rowspan="3">Class A (≤1.0%)</td>
<td>PL2</td>
<td>99.0% or more</td>
<td colspan="2">≤298g (Avg 288g)</td>
<td rowspan="5">Li-ion Rechargeable<br />
Voltage: 3.7V<br />
Capacity: 1100mAh<br />
Charging: ~3 hours*3<br />
Cycles: ~300 times*3</td>
<td>Approx. 6.7 hours</td>
<td>Approx. 4–9 hours</td>
</tr>
<tr>
<td class="product">BL-1005/AL</td>
<td rowspan="3">PL1</td>
<td>95.0% or more</td>
<td colspan="2">≤278g (Avg 271g)</td>
<td rowspan="2">Approx. 8.5 hours</td>
<td rowspan="2">Approx. 3.5–11 hours</td>
</tr>
<tr>
<td class="product">BL-1005X/AL</td>
<td>95.0% or more</td>
<td colspan="2">≤285g (Avg 278g)</td>
</tr>
<tr>
<td class="product">BL-321S</td>
<td rowspan="13">High Airflow</td>
<td>Class B (≤5.0%)</td>
<td>95.0% or more</td>
<td colspan="2">≤252g (Avg 244g)</td>
<td>Approx. 3.5 hours</td>
<td>Approx. 5–9 hours</td>
</tr>
<tr>
<td class="product">BL-321H</td>
<td>Class S (≤0.1%)</td>
<td>PL3</td>
<td>99.97% or more</td>
<td colspan="2">≤265g (Avg 257g)</td>
<td>Approx. 3 hours</td>
<td>Approx. 3–6 hours</td>
</tr>
<tr>
<td class="product">BL-351S</td>
<td>Class B (≤5.0%)</td>
<td>PL1</td>
<td>95.0% or more</td>
<td colspan="2">Avg 315g</td>
<td rowspan="11">Li-ion Rechargeable<br />
Voltage: 7.2V<br />
Capacity: 2000mAh<br />
Charging: ~3 hours*3<br />
Cycles: ~300 times*3</td>
<td>Approx. 10 hours</td>
<td>Approx. 13–22 hours</td>
</tr>
<tr>
<td class="product">BL-351H</td>
<td rowspan="3">Class S (≤0.1%)</td>
<td rowspan="3">PL3</td>
<td>99.97% or more</td>
<td colspan="2" rowspan="2">Avg 328g</td>
<td rowspan="3">Approx. 9 hours</td>
<td rowspan="3">Approx. 8–17 hours</td>
</tr>
<tr>
<td class="product">BL-351U</td>
<td>99.99% or more</td>
</tr>
<tr>
<td class="product">BL-351HX</td>
<td>99.97% or more</td>
<td colspan="2">Avg 333g</td>
</tr>
<tr>
<td class="product">BL-200S</td>
<td>Class B (≤5.0%)</td>
<td>PL1</td>
<td>95.0% or more</td>
<td>≤395g</td>
<td>Avg 219g</td>
<td>Approx. 10.5 hours</td>
<td>Approx. 12–22 hours</td>
</tr>
<tr>
<td class="product">BL-200H</td>
<td rowspan="2">Class S (≤0.1%)</td>
<td rowspan="2">PL3</td>
<td>99.97% or more</td>
<td rowspan="2">≤409g</td>
<td rowspan="2">Avg 234g</td>
<td rowspan="2">Approx. 9.5 hours</td>
<td rowspan="2">Approx. 10–18 hours</td>
</tr>
<tr>
<td class="product">BL-200U</td>
<td>99.99% or more</td>
</tr>
<tr>
<td class="product">BL-100S</td>
<td rowspan="2">Class B (≤5.0%)</td>
<td rowspan="2">PL1</td>
<td rowspan="2">95.0% or more</td>
<td rowspan="2">≤383g</td>
<td rowspan="2">Avg 206g</td>
<td rowspan="2">Approx. 10 hours</td>
<td rowspan="2">Approx. 12–22 hours</td>
</tr>
<tr>
<td class="product">BL-100SC</td>
</tr>
<tr>
<td class="product">BL-100H</td>
<td rowspan="2">Class S (≤0.1%)</td>
<td rowspan="2">PL3</td>
<td>99.97% or more</td>
<td rowspan="2">≤397g</td>
<td rowspan="2">Avg 222g</td>
<td rowspan="2">Approx. 9 hours</td>
<td rowspan="2">Approx. 10–18 hours</td>
</tr>
<tr>
<td class="product">BL-100U</td>
<td>99.99% or more</td>
</tr>
</tbody>
</table>
<div class="note">
<div>*1 Calculated duration for maintaining positive pressure inside the facepiece under standard indoor conditions.</div>
<div>*2 Observed duration for maintaining positive pressure in dusty environments, based on actual worker respiratory data during field work.</div>
<div>*3 May vary or be shorter depending on actual usage conditions.</div>
</div>
<h3>Replacement Filters</h3>
<table>
<tbody>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt; width: 48pt;" width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56599" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_155832-removebg-preview.png" alt="" width="201" height="127" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56598" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_155838-removebg-preview.png" alt="" width="200" height="128" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56597" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_155847-removebg-preview.png" alt="" width="177" height="129" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56600" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-155854.png" alt="" width="182" height="133" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56594" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-155741.png" alt="" width="174" height="126" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56595" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-155749.png" alt="" width="164" height="130" /></td>
<td style="width: 48pt;" width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56596" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-155757.png" alt="" width="182" height="131" /></td>
</tr>
<tr style="height: 14.4pt;">
<td style="height: 14.4pt;" height="19"><strong>Alpha Ring Filter BRD-82</strong> Screw-on type</td>
<td><strong>Alpha Ring Filter BRD-82U</strong> Screw-on type</td>
<td><strong>Alpha Ring Filter BLA-62</strong> Screw-on type</td>
<td><strong>Alpha Ring Filter BRD-7</strong></td>
<td><strong>Alpha Ring Filter BRD-8U</strong></td>
<td><strong>Alpha Ring Filter BLA-6</strong></td>
<td><strong>Alpha Ring Filter BLA-6C</strong></td>
</tr>
</tbody>
</table>
<p>● When performing tasks such as welding or grinding that generate sparks or spatter, it is mandatory to install the dedicated inhalation port cover (sold separately) on the filter (except for the BL-7005 and BL-1005 series). Note that the BL-700HA/U, BL-200H/U, and BL-100H/U series are not designed for use in environments with sparks or spatter.</p>
<h3>Features:</h3>
<ul>
<li data-path-to-node="2,0,0"><b data-path-to-node="2,0,0" data-index-in-node="0">High Synchro:</b> Next-generation model improves airflow efficiency and tracks user breathing rhythm more accurately.</li>
<li data-path-to-node="2,1,0"><b data-path-to-node="2,1,0" data-index-in-node="0">Fit Checker:</b> Easily perform a fit test by simply pulling the lever.</li>
<li data-path-to-node="2,2,0"><b data-path-to-node="2,2,0" data-index-in-node="0">Under Chin:</b> Unique curved design enhances the airtight seal at the face contact area.</li>
<li data-path-to-node="2,3,0"><b data-path-to-node="2,3,0" data-index-in-node="0">Micron:</b> High-performance electrostatic filter. This respirator utilizes Micron filter technology.</li>
<li data-path-to-node="2,4,0"><b data-path-to-node="2,4,0" data-index-in-node="0">Speaker:</b> Integrated small communication speaker ensures clear dialogue while wearing the mask.</li>
<li data-path-to-node="2,5,0"><b data-path-to-node="2,5,0" data-index-in-node="0">Special Hard Coating:</b> Improved scratch resistance compared to standard surface hardening methods.</li>
<li data-path-to-node="2,6,0"><b data-path-to-node="2,6,0" data-index-in-node="0">Silicone:</b> The facepiece uses high-grade silicone material for a soft, skin-friendly fit.</li>
<li data-path-to-node="2,7,0"><b data-path-to-node="2,7,0" data-index-in-node="0">Speaking Diaphragm:</b> Facilitates clear communication and instruction without mask removal.</li>
<li data-path-to-node="2,8,0"><b data-path-to-node="2,8,0" data-index-in-node="0">Internal Pressure Monitoring:</b> Flashing light alerts the user when positive pressure is lost inside the facepiece.</li>
<li data-path-to-node="2,9,0"><b data-path-to-node="2,9,0" data-index-in-node="0">HAWC Lip:</b> Full-face models use the HAWC Lip structure for a high-seal &#8220;suction cup effect.&#8221;</li>
<li data-path-to-node="2,10,0"><b data-path-to-node="2,10,0" data-index-in-node="0">Hardened Eyepiece:</b> The visor surface is treated with a hardening process to resist scratches.</li>
</ul>The post <a href="https://koueitrading.com/global/product/koken-bl-351-series-p-papr/">Koken BL-351 Series P-PAPR</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken BL-200 Series P-PAPR</title>
		<link>https://koueitrading.com/global/product/koken-bl-200-series-p-papr/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Wed, 04 Mar 2020 06:49:01 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=191661</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: BL-200 Series P-PAPR: Powered Air-Purifying Particulate Respirator PARTICULATE PAPR and GAS PAPR PAPR: Powered Air-Purifying Respirator. P-PAPR: Particulate PAPR (Used for dust/particles). G-PAPR: Gas PAPR (Used for toxic gases/vapors). Within the PAPR range, there are “Powered Air-Purifying Particulate Respirators (P-PAPR)” for dust hazards and “Powered Air-Purifying Gas Respirators (G-PAPR)” for toxic [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-bl-200-series-p-papr/">Koken BL-200 Series P-PAPR</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: BL-200 Series</p>
<p>P-PAPR: Powered Air-Purifying Particulate Respirator</p>
<h2>PARTICULATE PAPR and GAS PAPR</h2>
<ul>
<li data-path-to-node="14,0,0">PAPR: Powered Air-Purifying Respirator.</li>
<li data-path-to-node="14,1,0">P-PAPR: Particulate PAPR (Used for dust/particles).</li>
<li data-path-to-node="14,2,0">G-PAPR: Gas PAPR (Used for toxic gases/vapors).</li>
</ul>
<p data-path-to-node="3">Within the PAPR range, there are “Powered Air-Purifying Particulate Respirators (P-PAPR)” for dust hazards and “Powered Air-Purifying Gas Respirators (G-PAPR)” for toxic gas hazards. It is essential to understand the properties, type, and concentration of the hazardous substances before selecting the appropriate mask.</p>
<p data-path-to-node="3">To prevent inhalation of DUST -&gt; Use a Powered Air-Purifying Particulate Respirator (P-PAPR)<br />
To prevent inhalation of TOXIC GAS -&gt; Use a Powered Air-Purifying Gas Respirator (G-PAPR)<br />
To prevent inhalation of MIXED DUST &amp; TOXIC GAS -&gt; Use a Powered Air-Purifying Gas Respirator (G-PAPR) with dust protection function</p>
<h3>Environments where PAPR CANNOT be used</h3>
<p data-path-to-node="9">PAPR must not be used if any of the following conditions apply. Please use respiratory protective equipment suitable for the environment, such as a supplied-air respirator or a self-contained breathing apparatus (SCBA).</p>
<ul>
<li data-path-to-node="10,0,0">Oxygen-deficient environments or those at risk of oxygen deficiency (Oxygen concentration below 18%).</li>
<li data-path-to-node="10,1,0">Cases where the type or concentration of the toxic gas is unknown.</li>
<li data-path-to-node="10,2,0">IDLH environments (Atmospheres Immediately Dangerous to Life or Health).</li>
<li data-path-to-node="10,2,0">Cases where the toxic gas concentration exceeds the permissible limit for the PAPR. ※</li>
<li data-path-to-node="10,3,0">Cases where no filter (canister) is available to remove the specific toxic gas in the environment.</li>
<li data-path-to-node="10,4,0">Cases where a mixture of gases with different properties exists.</li>
<li data-path-to-node="10,5,0">Cases where the environment deviates significantly from normal temperature, humidity, and atmospheric pressure.</li>
</ul>
<p data-path-to-node="11">(※ According to standards based on the Industrial Safety and Health Act, the application range of G-PAPR is 2% (3% for Ammonia))</p>
<h3>SELECTING THE APPROPRIATE PAPR BASED ON HAZARD CONCENTRATION</h3>
<p data-path-to-node="3">Determine the Required Protection Factor, then select a PAPR model with an Assigned Protection Factor higher than that value.</p>
<p data-path-to-node="4,0">Formula: How to calculate the Required Protection Factor<br />
<strong>Required Protection Factor = Ambient concentration of identified hazard / Permissible exposure limit of the hazard</strong></p>
<p>Assigned Protection Factor of P-PAPR</p>
<table>
<thead>
<tr>
<th colspan="2"><strong>Classification</strong></th>
<th colspan="4"><strong>Facepiece Type</strong></th>
</tr>
<tr>
<th><strong>Leakage Rate</strong></th>
<th><strong>Filter Efficiency</strong></th>
<th><strong>Half-face</strong></th>
<th><strong>Full-face</strong></th>
<th><strong>Hood Type</strong></th>
<th><strong>Face shield</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td rowspan="3">Class S</td>
<td>PL3/PS3</td>
<td>50/300</td>
<td>1000</td>
<td>25/1000</td>
<td>25/300</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>—</td>
<td>—</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td rowspan="3">Class A</td>
<td>PL3/PS3</td>
<td>—</td>
<td>—</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>33</td>
<td>90</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>14</td>
<td>19</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td rowspan="3">Class B</td>
<td>PL3/PS3</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>14</td>
<td>19</td>
<td>11</td>
<td>11</td>
</tr>
</tbody>
</table>
<p>Assigned Protection Factor of G-PAPR</p>
<table>
<thead>
<tr>
<th class="header-main" colspan="4"><strong>Facepiece Type</strong></th>
</tr>
<tr>
<th><strong>Half-face</strong></th>
<th><strong>Full-face</strong></th>
<th><strong>Hood Type</strong></th>
<th><strong>Face shield</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>50/300</td>
<td>1000</td>
<td>25/1000</td>
<td>25/300</td>
</tr>
</tbody>
</table>
<p>For “G-PAPR with dust protection function,” please refer to the Assigned Protection Factor of P-PAPR (Class S leakage rate) mentioned above for dust (and similar particulates).</p>
<h2>TASKS WHERE PAPR USE IS MANDATORY BY REGULATION OR DIRECTIVE</h2>
<p><strong>For tasks where PAPR use is mandatory by regulation or directive, please use a PAPR with the designated performance classification.</strong></p>
<h4><strong>1. Tunnel Construction Work</strong></h4>
<p><strong>Regulation:</strong> “Ordinance on Prevention of Pneumoconiosis”<br />
<strong>Scope:</strong> In tunnel construction, at locations involving “mechanical/powered excavation,” “mechanical loading or unloading of ore/rock,” and “shotcreting.”</p>
<p><strong>PAPR Requirements:</strong></p>
<ul>
<li>National test certified product (High airflow type).</li>
<li>Tight-fitting facepiece type where the battery can be removed for use during blasting operations.</li>
</ul>
<h4><strong>2. Asbestos Removal Work</strong></h4>
<p><strong>Regulation:</strong> “Ordinance on Prevention of Health Impairment due to Asbestos”<br />
<strong>Scope</strong>: In asbestos removal tasks, specifically those requiring “Class 1 Asbestos Removal Masks.”<br />
<b data-path-to-node="11,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified tight-fitting or hood types (High airflow, Class S, PL3 or PS3).</p>
<h4 data-path-to-node="12"><b data-path-to-node="12" data-index-in-node="0">3. Handling Nanomaterials</b></h4>
<p data-path-to-node="13,0,0"><b data-path-to-node="13,0,0" data-index-in-node="0">Directive:</b> “Regarding Preventive Measures for Exposure to Nanomaterials”<br />
<b data-path-to-node="13,1,0" data-index-in-node="0">Scope:</b> Manufacturing and handling of nanomaterials. (※)<br />
<b data-path-to-node="13,2,0" data-index-in-node="0">PAPR Requirements:</b></p>
<ul>
<li data-path-to-node="13,2,0">National test certified product (High airflow, PL3 or PS3).</li>
<li data-path-to-node="13,2,1,0,0">Shape limitations based on the projected exposure levels of workers.</li>
</ul>
<p data-path-to-node="13,2,1,1,0">(※) Depending on the work environment, respiratory protective equipment other than PAPR may be used.</p>
<h4 data-path-to-node="14"><b data-path-to-node="14" data-index-in-node="0">4. Handling Indium</b></h4>
<p data-path-to-node="15,0,0"><b data-path-to-node="15,0,0" data-index-in-node="0">Directive:</b> “Regarding Thorough Health Hazard Prevention Measures for Indium/Tin Oxide Handling”<br />
<b data-path-to-node="15,1,0" data-index-in-node="0">Scope:</b> Handling of Indium, Tin Oxide, etc. (※)<br />
<b data-path-to-node="15,2,0" data-index-in-node="0">PAPR Requirements:</b></p>
<ul>
<li data-path-to-node="15,2,0">National test certified product (High airflow, PL3 or PS3).</li>
<li data-path-to-node="15,2,1,0,0">Limitations on shape and leakage rate based on working environment measurement results.</li>
</ul>
<p data-path-to-node="15,2,1,1,0">(※) Depending on environmental results, respiratory protective equipment other than PAPR may be used.</p>
<h4 data-path-to-node="16"><b data-path-to-node="16" data-index-in-node="0">5. Handling Dioxins</b></h4>
<p><b data-path-to-node="17,0,0" data-index-in-node="0">Directive:</b> “Revision of Guidelines for Dioxin Exposure Prevention in Waste Incineration Facilities”<br />
<b data-path-to-node="17,1,0" data-index-in-node="0">Scope:</b> For dioxin-exposure risk tasks classified as “Level 1.” (※)<br />
<b data-path-to-node="17,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified product (High airflow, PL3 or PS3).</p>
<p>(※) RL3 or RS3 dust masks may be used, but PAPR with higher protective performance is recommended.</p>
<h4 data-path-to-node="18"><b data-path-to-node="18" data-index-in-node="0">6. Handling Refractory Ceramic Fibers (RCF)</b></h4>
<p><b data-path-to-node="19,0,0" data-index-in-node="0">Regulation:</b> “Ordinance on Prevention of Hazards due to Specified Chemical Substances”<br />
<b data-path-to-node="19,1,0" data-index-in-node="0">Scope:</b> Insulation or fireproofing work involving the application of RCF to furnaces or boilers; or repair, dismantling, and demolition of such furnaces/boilers.<br />
<b data-path-to-node="19,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified product (PL3 or PS3).</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong>PAPR Standards</strong></th>
<td width="64">Beyond JIS standards, Powered Air-Purifying Respirators must adhere to standards defined under the Industrial Safety and Health Act. These comprehensive standards ensure that products are manufactured under strict safety requirements.</td>
</tr>
</tbody>
</table>
<p>The following table is excerpted from the ‘Standards for Powered Air-Purifying Respirators’</p>
<h3>Types of Powered Air-Purifying Respirators</h3>
<table>
<tbody>
<tr>
<th colspan="2"><strong>Powered Air-Purifying Particulate Respirator (P-PAPR)</strong></th>
</tr>
<tr>
<th rowspan="2"><strong>Powered Air-Purifying Gas Respirator (G-PAPR)</strong></th>
<td>Type with dust protection function</td>
</tr>
<tr>
<td>Type without dust protection function</td>
</tr>
</tbody>
</table>
<p><strong>■ Classification by Shape</strong></p>
<table>
<tbody>
<tr>
<th rowspan="2"><strong>Tight-fitting Facepiece</strong><br />
<span class="sub-item">・Full-face</span><br />
<span class="sub-item">・Half-face</span></th>
<td>Isolation type (with hose)</td>
</tr>
<tr>
<td>Direct connection type</td>
</tr>
<tr>
<th rowspan="2"><strong>Loose-fitting Facepiece</strong><br />
<span class="sub-item">・Hood</span><br />
<span class="sub-item">・Face shield</span></th>
<td>Isolation type (with hose)</td>
</tr>
<tr>
<td>Direct connection type</td>
</tr>
</tbody>
</table>
<p><strong>■ Classification by Performance</strong></p>
<table>
<thead>
<tr>
<th><strong>Airflow Performance Classification</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>Standard airflow type</td>
</tr>
<tr>
<td>High airflow type</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th><strong>Leakage Rate Performance Classification (P-PAPR)</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>Class B</td>
</tr>
<tr>
<td>Class A</td>
</tr>
<tr>
<td>Class S</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th colspan="2"><strong>Filter Material Performance Classification<br />
(P-PAPR and G-PAPR with dust function)</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td width="50%">PS1</td>
<td width="50%">PL1</td>
</tr>
<tr>
<td>PS2</td>
<td>PL2</td>
</tr>
<tr>
<td>PS3</td>
<td>PL3</td>
</tr>
</tbody>
</table>
<h3>Performance Testing for Powered Air-Purifying Respirators</h3>
<h4><strong>■ Particle Collection Efficiency Test</strong></h4>
<p>(Applies only to P-PAPR and G-PAPR with dust protection)</p>
<table>
<tbody>
<tr>
<th class="header-bg col-label" rowspan="3"><strong>Test Particle</strong></th>
<th class="header-bg col-sub"><strong>Type</strong></th>
<td class="align-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="align-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="header-bg"><strong>Particle Size</strong></th>
<td colspan="2">0.06μm ~ 0.1μm</td>
<td colspan="2">0.15μm ~ 0.25μm</td>
</tr>
<tr>
<th class="header-bg"><strong>Concentration</strong></th>
<td colspan="2">50mg/m³ or less</td>
<td colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="header-bg" rowspan="2"><strong>Test Flow Rate</strong></th>
<th class="header-bg"><strong>Standard Flow</strong></th>
<td colspan="4">104 L/min</td>
</tr>
<tr>
<th class="header-bg"><strong>High Flow</strong></th>
<td colspan="4">138 L/min</td>
</tr>
<tr>
<th class="header-bg align-left" colspan="2" rowspan="4"><strong>Collection Efficiency<br />
(Continuous measurement; must meet values in the right column)</strong></th>
<td colspan="2">For NaCl, loaded up to 200mg</td>
<td colspan="2">For DOP, loaded up to 400mg</td>
</tr>
<tr>
<td class="col-val">PS1</td>
<td class="col-res">95.0% or more</td>
<td class="col-val">PL1</td>
<td class="col-res">95.0% or more</td>
</tr>
<tr>
<td>PS2</td>
<td>99.0% or more</td>
<td>PL2</td>
<td>99.0% or more</td>
</tr>
<tr>
<td>PS3</td>
<td>99.97% or more</td>
<td>PL3</td>
<td>99.97% or more</td>
</tr>
</tbody>
</table>
<h4><strong>■ Canister Testing</strong></h4>
<p>(Applies only to G-PAPR)</p>
<table>
<tbody>
<tr>
<th><strong>Airtightness</strong></th>
<td class="align-left" colspan="4">No air leakage at 1470 Pa pressure</td>
</tr>
<tr>
<th rowspan="5"><strong>Decontamination Capacity<br />
(Time until breakthrough at specified concentration must be ≥ the right column)</strong></th>
<th><strong>Type</strong></th>
<th><strong>Test Gas</strong></th>
<th><strong>Breakthrough Concentration</strong></th>
<th><strong>Duration</strong></th>
</tr>
<tr>
<td>Halogen gas</td>
<td>Chlorine (0.02%)</td>
<td>1 ppm</td>
<td>40 mins or more</td>
</tr>
<tr>
<td>Organic gas</td>
<td>Cyclohexane (0.03%)</td>
<td>5 ppm</td>
<td>50 mins or more</td>
</tr>
<tr>
<td>Ammonia</td>
<td>Ammonia (0.1%)</td>
<td>50 ppm</td>
<td>40 mins or more</td>
</tr>
<tr>
<td>SO₂ gas</td>
<td>Sulfur dioxide (0.03%)</td>
<td>5 ppm</td>
<td>35 mins or more</td>
</tr>
<tr>
<th><strong>Leakage Concentration</strong></th>
<td class="align-left" colspan="4">At maximum flow rate, time to reach breakthrough must be ≥ 3 minutes.</td>
</tr>
</tbody>
</table>
<h4><strong>■ Inward Leakage Rate Test</strong></h4>
<table>
<colgroup>
<col />
<col />
<col />
<col /></colgroup>
<tbody>
<tr>
<th rowspan="3"><strong>Test Particle</strong></th>
<th><strong>Type</strong></th>
<td colspan="4">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<th><strong>Particle Size</strong></th>
<td colspan="4">0.06μm ~ 0.2μm</td>
</tr>
<tr>
<th><strong>Concentration</strong></th>
<td colspan="4">18mg/m³ or less</td>
</tr>
<tr>
<th rowspan="4"><strong>Simulated Breathing</strong></th>
<th><strong>Type</strong></th>
<td colspan="2">Standard Flow</td>
<td colspan="2">High Flow</td>
</tr>
<tr>
<th><strong>Waveform</strong></th>
<td colspan="4">Sine wave</td>
</tr>
<tr>
<th><strong>Ventilation Volume</strong></th>
<td colspan="2">1.5 ± 0.075 L/stroke</td>
<td colspan="2">1.6 ± 0.08 L/stroke</td>
</tr>
<tr>
<th><strong>Frequency</strong></th>
<td colspan="2">20 times/min</td>
<td colspan="2">25 times/min</td>
</tr>
<tr>
<th colspan="2" rowspan="4"><strong>Leakage Rate<br />
(2-minute continuous measurement; max value must meet the right column)</strong></th>
<td rowspan="3">P-PAPR</td>
<td>Class B</td>
<td colspan="2">5.0% or less</td>
</tr>
<tr>
<td>Class A</td>
<td colspan="2">1.0% or less</td>
</tr>
<tr>
<td>Class S</td>
<td colspan="2">0.1% or less</td>
</tr>
<tr>
<td>G-PAPR</td>
<td colspan="3">0.1% or less</td>
</tr>
<tr>
<th colspan="2" rowspan="4"><strong>Headform Movement<br />
(Calculate leakage rate for each item)</strong></th>
<th colspan="3"><strong>Position and Range</strong></th>
<th><strong>Frequency</strong></th>
</tr>
<tr>
<td rowspan="2">Head</td>
<td colspan="2">Front/Back 30 degrees</td>
<td>17 times/min</td>
</tr>
<tr>
<td colspan="2">Left/Right rotation 50 degrees</td>
<td>11 times/min</td>
</tr>
<tr>
<td>Arms</td>
<td colspan="2">Raising 10 ~ 130 degrees</td>
<td>7 times/min</td>
</tr>
</tbody>
</table>
<h4><strong>■ Other Tests</strong></h4>
<table>
<tbody>
<tr>
<th><strong>Internal Pressure<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">Under simulated breathing identical to the leakage test:<br />
0 Pa &lt; Internal Mask Pressure &lt; 400 Pa</td>
</tr>
<tr>
<th rowspan="2"><strong>Minimum Required Flow<br />
(Loose-fit only)</strong></th>
<td class="align-center">Standard Flow</td>
<td class="align-center">104 L/min or more</td>
</tr>
<tr>
<td class="align-center">High Flow</td>
<td class="align-center">138 L/min or more</td>
</tr>
<tr>
<th><strong>Inhalation Resistance<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">160 Pa or less<br />
(40 L/min flow rate, fan OFF)</td>
</tr>
<tr>
<th><strong>Exhalation Resistance<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">80 Pa or less<br />
(40 L/min flow rate, fan OFF)</td>
</tr>
<tr>
<th><strong>Exhalation Valve Airtightness<br />
(Tight-fitting only)</strong></th>
<td class="content-cell" colspan="2">・Internal pressure must drop immediately when air is sucked.<br />
・Time for pressure to return to normal must be ≥ 15 seconds.</td>
</tr>
<tr>
<th><strong>CO2 Concentration Increase<br />
(Tight-fitting only)</strong></th>
<td class="content-cell" colspan="2">With fan OFF, headform breathes CO2 air. Difference between wearing and not wearing mask must be &lt; 2.0%.</td>
</tr>
<tr>
<th><strong>Noise Level</strong></th>
<td class="align-center" colspan="2">Noise at the headform ear area must be below 80 dB (both sides).</td>
</tr>
<tr>
<th rowspan="4"><strong>Flow Rate<br />
(G-PAPR only)</strong></th>
<td>Max set average flow</td>
<td class="content-cell">Average must be ≤ the decontamination test flow rate.</td>
</tr>
<tr>
<td>Maximum flow</td>
<td class="content-cell">Maximum must be ≤ the flow rate set by the manufacturer.</td>
</tr>
<tr>
<th><strong>Tight-fitting type</strong></th>
<th><strong>Loose-fitting type</strong></th>
</tr>
<tr>
<td class="content-cell">Measure resistance with fan OFF/ON at 20~170 L/min to calculate flow per minute.</td>
<td class="content-cell">With fan ON, draw air for 5 mins to maintain normal pressure in chamber, then measure flow.</td>
</tr>
</tbody>
</table>
<h2>PAPR USE IS ENCOURAGED IN THE 10TH COMPREHENSIVE DUST HAZARD COUNTERMEASURES</h2>
<p><strong>To reduce pneumoconiosis, dust prevention measures must be strengthened.</strong></p>
<p>The “10th Comprehensive Countermeasures for Preventing Dust Hazards” demands the correct use of effective respiratory protection against dust exposure across all industries. PAPR is highlighted as a “more effective preventive measure for health impairment,” and its adoption is highly encouraged.<br />
The use of PAPR is more effective in preventing health impairment compared to standard dust masks due to its higher protection factor and reduced physical strain on the wearer.<br />
(Partial excerpt from the 10th Comprehensive Countermeasures)</p>
<p>Furthermore, due to high performance, PAPR is mandatory for specific tasks, but its use is also recommended for tasks outside the mandatory categories.<br />
While PAPR is mandatory for specific operations under the Dust Rules, its high performance makes it desirable for other tasks; thus, guidance and inspections encourage businesses to adopt PAPR for their workers.<br />
(Partial excerpt from the 10th Comprehensive Countermeasures)</p>
<h2>KOKEN BL SERIES BREATH-RESPONSIVE PAPR</h2>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Achieving “High Safety” and “Comfortable Fit” as expected</b></p>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">THE EVOLUTION OF THE BL SERIES</b></p>
<p data-path-to-node="6">The BL Series continues to evolve into the PAPR model that helps perfect safety and health management in every field, aligning with occupational health trends and market expansion.</p>
<p data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">CORE DEVELOPMENT FOCUS</b></p>
<ul>
<li data-path-to-node="8,0,0"><b data-path-to-node="8,0,0" data-index-in-node="0">“Safety”:</b> Improving the protection capability as a respirator.</li>
<li data-path-to-node="8,1,0"><b data-path-to-node="8,1,0" data-index-in-node="0">“Flow Technology”:</b> Minimizing waste and improving efficiency.</li>
<li data-path-to-node="8,2,0"><b data-path-to-node="8,2,0" data-index-in-node="0">“Lightweight Design”:</b> Reducing the burden on the worker.</li>
</ul>
<h2>KOKEN FLOW TECHNOLOGY: New BSFS air flow highly synchronized with breathing</h2>
<h3>THE MECHANISM OF THE BSFS (BREATH SYNCHRONIZED) SYSTEM</h3>
<p data-path-to-node="5">The BL Series is equipped with the Breath Synchronized-Air Flow System (new BSFS), which delivers airflow that follows the breathing rhythm more closely than ever, becoming a “Highly Synchronized” model.<br />
BSFS ELIMINATES THE FEELING OF BREATHLESSNESS/STUFFINESS<br />
<img loading="lazy" decoding="async" class="size-medium wp-image-191639 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-300x177.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-300x177.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4.jpg 464w" alt="" width="300" height="177" /></p>
<p><b data-path-to-node="2" data-index-in-node="0">THE BSFS MECHANISM HAS EVOLVED INTO “HIGH SYNCHRONIZATION”</b></p>
<p data-path-to-node="3">Using a fan equipped with a breath detection sensor, the device supplies “the necessary and sufficient amount of air” corresponding to the user’s inhalation. Responsiveness to breathing has been improved, and the accuracy of synchronization with the respiratory rhythm has significantly increased.<br />
<img loading="lazy" decoding="async" class="size-medium wp-image-191638 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-300x286.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-300x286.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-768x733.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1.jpg 1024w" alt="" width="300" height="286" /></p>
<h3>COMFORT UP</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">SOLVING MASK DISCOMFORT WITH FLOW THAT FOLLOWS EVERY BREATH</b></p>
<ul>
<li data-path-to-node="4,0,0">Reduces the physical workload for laborers.</li>
<li data-path-to-node="4,1,0">Solves breathing difficulties and stuffiness in high-temperature workplaces.</li>
</ul>
<h3>SAFETY UP</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">PREVENTING INWARD LEAKAGE THROUGH HIGH PROTECTION AND CONSTANT POSITIVE PRESSURE</b></p>
<p data-path-to-node="4,0,0">Breath Synchronization: Protection is guaranteed by the blower linked to breathing.</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class=" wp-image-191633 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-300x227.jpg" sizes="auto, (max-width: 441px) 100vw, 441px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-300x227.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-768x581.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6.jpg 1024w" alt="" width="441" height="334" /></td>
<td width="64"><img loading="lazy" decoding="async" class=" wp-image-191636 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-300x218.png" sizes="auto, (max-width: 508px) 100vw, 508px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-300x218.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-1024x745.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-768x559.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185.png 1407w" alt="" width="508" height="369" /></td>
</tr>
<tr>
<td height="19">
<p data-path-to-node="3,0,0"><b data-path-to-node="3,0,0" data-index-in-node="0">DURING INHALATION:</b> Air inside the mask is normally sucked away, but supplemental airflow prevents negative pressure. (If a gap exists, air blows outward ※1)</p>
<p data-path-to-node="3,0,0">※1: Airflow varies based on facepiece fit.</p>
</td>
<td>
<p data-path-to-node="3,1,0"><b data-path-to-node="3,1,0" data-index-in-node="0">DURING EXHALATION:</b> Since pressure doesn’t drop, airflow is reduced. This conserves the “filter” and “battery.”</p>
<p data-path-to-node="3,1,0">※2: Flow doesn’t stop completely (maintains a small amount for safety).</p>
</td>
</tr>
</tbody>
</table>
<p><b data-path-to-node="2" data-index-in-node="0">PAPR AVOIDS HIGH LEAKAGE RISKS FROM DUST BUILDUP IN LOOSE MASKS</b></p>
<p data-path-to-node="3">FOR CONVENTIONAL DUST MASKS:</p>
<p data-path-to-node="4">As dust builds on the filter, inhalation resistance increases, raising the risk of inward leakage. As dust accumulates, even if the gap remains the same, the leakage rate can double. (See diagram below)</p>
<p><img loading="lazy" decoding="async" class=" wp-image-191632 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-300x195.jpg" sizes="auto, (max-width: 409px) 100vw, 409px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-300x195.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-768x500.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-180x118.jpg 180w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8.jpg 1024w" alt="" width="409" height="266" /></p>
<p><b data-path-to-node="7" data-index-in-node="0">Leakage Measurement Method:</b> A 2.5% gap is created intentionally; NaCl concentration is measured inside/outside the mask with a digital meter.</p>
<h3>ECONOMY UP (ECO)</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">ELIMINATING WASTE THROUGH AN ECO FLOW MECHANISM</b></p>
<p data-path-to-node="4,0,0">Limits “wasteful dust buildup” and reduces filter usage: Minimizes air loss to reduce clogging.<br />
Limits battery usage: Extends runtime by reducing power consumption during low-respiration phases.</p>
<p><b data-path-to-node="2" data-index-in-node="0">BATTERY RUNTIME COMPARISON: NEW VS OLD BSFS</b></p>
<p data-path-to-node="3"><img loading="lazy" decoding="async" class=" wp-image-191631 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/1-300x126.png" sizes="auto, (max-width: 445px) 100vw, 445px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/1-300x126.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-1024x429.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-768x322.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/1.png 1536w" alt="" width="445" height="187" /></p>
<p data-path-to-node="3"><strong>ECO FLOW CREATED BY HIGH SYNCHRONIZATION</strong></p>
<p data-path-to-node="3"><img loading="lazy" decoding="async" class=" wp-image-191630 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/2-300x175.png" sizes="auto, (max-width: 456px) 100vw, 456px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/2-300x175.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-1024x599.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-768x449.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/2.png 1536w" alt="" width="456" height="266" />Image of BSFS flow following actual respiratory waveforms with high precision.</p>
<h2 data-path-to-node="3">KOKEN LIGHTWEIGHT DESIGN: Reducing burden for long shifts</h2>
<p>The “BL Series” optimizes compact sizing and weight equivalent to conventional dust masks. It is highly rated in tunnel construction, asbestos handling, and arc welding.</p>
<p><b data-path-to-node="4" data-index-in-node="0">SEPARATE TYPE</b> Because a direct-mounted battery adds weight to the neck, the separate design reduces perceived weight. This ultra-lightweight design minimizes mask body thickness.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56541" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-122956.png" alt="" width="348" height="302" /></p>
<p><b data-path-to-node="5" data-index-in-node="0">BUILT-IN TYPE</b> Thanks to “High Synchro” BSFS reducing power draw, battery size has been shrunk. This results in a lightweight built-in battery design with minimal burden.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56542" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123026.png" alt="" width="212" height="269" /></p>
<h2>KOKEN SAFETY DESIGN: Internal pressure monitoring to maintain positive pressure</h2>
<p data-path-to-node="3">(Common for BL-321/BL-351/BL-351X/BL-711/BL-700/BL-200/BL-100 series)</p>
<p data-path-to-node="4">Modern worksites require PAPRs that “constantly monitor internal pressure and provide alerts.”<br />
PAPR is most protective under positive pressure; therefore, the moment positive pressure cannot be maintained is the filter replacement time. “Internal monitoring” notifies the user when pressure drops due to weak flow.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56543" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123245.png" alt="" width="243" height="253" /></p>
<p data-path-to-node="7,0,0">■ Positive pressure inside the mask can be maintained through timely/appropriate filter replacement.<br />
■ Clarifies the standard for filter replacement – which is otherwise often vague or based on subjective estimation.<br />
■ Full airflow can be restored through proper battery charging.</p>
<p><b data-path-to-node="2" data-index-in-node="0">NOTIFICATION VIA AIRFLOW</b></p>
<p data-path-to-node="3">(For BL-321 / BL-351 / BL-351X / BL-711 series)</p>
<ul>
<li data-path-to-node="4,0,0">Pressure drop warning via “Continuous Airflow”: ➔ Replace the filter.</li>
<li data-path-to-node="4,1,0">Low battery warning via “Rhythmic Airflow”: ➔ Replace with a charged battery.</li>
</ul>
<p><b data-path-to-node="6" data-index-in-node="0">LED NOTIFICATION</b></p>
<p data-path-to-node="7">(For BL-700 / BL-200 / BL-100 series)</p>
<ul>
<li data-path-to-node="8,0,0">Pressure drop warning via “Flashing LED”: ➔ Replace the filter.</li>
<li data-path-to-node="8,1,0">Low battery warning via “Steady LED”: ➔ Replace with a charged battery.</li>
</ul>
<p><img loading="lazy" decoding="async" class=" wp-image-191629 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/3-300x65.png" sizes="auto, (max-width: 471px) 100vw, 471px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/3-300x65.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-1024x221.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-768x166.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/3.png 1536w" alt="" width="471" height="102" /></p>
<h2>POWERED AIR-PURIFYING PARTICULATE RESPIRATOR (P-PAPR)</h2>
<h3>BL-200 SERIES</h3>
<p><strong>PAPR with a speech diaphragm for easy conversation even in noisy environments<br />
</strong><b data-path-to-node="3,0,0" data-index-in-node="0">Separate battery type for a lighter mask experience</b></p>
<p data-path-to-node="4,0,0"><b data-path-to-node="4,0,0" data-index-in-node="0">Classification:</b> <b data-path-to-node="4,0,0" data-index-in-node="11">HIGH AIRFLOW TYPE</b></p>
<p data-path-to-node="4"><strong>Features:</strong></p>
<ul>
<li data-path-to-node="5,0,0">High Synchro</li>
<li data-path-to-node="5,1,0">Internal Pressure Monitoring</li>
<li data-path-to-node="5,2,0">Under Chin Design</li>
<li data-path-to-node="5,3,0">Silicone Material</li>
<li data-path-to-node="5,4,0">Speaking Diaphragm</li>
</ul>
<p data-path-to-node="1,0,0">■ Speaking diaphragm for fluid communication</p>
<ul>
<li data-path-to-node="1,0,1,0,0">Lightweight even with an integrated speaking diaphragm!</li>
<li data-path-to-node="1,0,1,0,0">Risk management measure! Instructions can be given without removing the mask during site management and guidance.</li>
</ul>
<p data-path-to-node="1,1,0">■ Positive pressure is constantly managed via the internal pressure monitoring function.</p>
<p data-path-to-node="1,1,0"><img loading="lazy" decoding="async" class="size-medium wp-image-191654 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/7237c887-4a81-4077-a69a-9373ed49a1ae-300x200.png" alt="" width="300" height="200" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/7237c887-4a81-4077-a69a-9373ed49a1ae-300x200.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/7237c887-4a81-4077-a69a-9373ed49a1ae-1024x683.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/7237c887-4a81-4077-a69a-9373ed49a1ae-768x512.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/7237c887-4a81-4077-a69a-9373ed49a1ae.png 1536w" sizes="auto, (max-width: 300px) 100vw, 300px" /></p>
<h3 data-path-to-node="1"><b data-path-to-node="1" data-index-in-node="0">Optional: Dedicated Hood for Half-face Masks (※)</b></h3>
<p data-path-to-node="2">For use at worksites with high dust emission levels.</p>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Type 1 Hood (1 pc/pack)</b></p>
<ul>
<li data-path-to-node="4,0,0">Disposable</li>
<li data-path-to-node="4,1,0">Anti-fog treatment</li>
<li data-path-to-node="4,2,0">Can be used with standard prescription glasses</li>
</ul>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Type 2 Hood (10 pcs/set) is also available (no anti-fog treatment).</b></p>
<p data-path-to-node="5"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56604" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-20-103449.png" alt="" width="116" height="113" /></p>
<p style="text-align: left;" data-path-to-node="6">(※ Except for BL-7005 and BL-1005 series)</p>
<h3 data-path-to-node="6"><b data-path-to-node="1" data-index-in-node="0">Sakai Type</b> <b data-path-to-node="1" data-index-in-node="11">BL-200S-02</b></h3>
<p>Includes battery &amp; charger. Pattern Test Cert No. TP16</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56605" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-20_103422-removebg-preview.png" alt="" width="349" height="311" /></p>
<ul>
<li data-path-to-node="2,0,0">PL1</li>
<li data-path-to-node="2,1,0">Class B</li>
<li data-path-to-node="2,2,0">Assigned Protection Factor: 14</li>
</ul>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Applications:</b></p>
<ul>
<li data-path-to-node="4,0,0">General dust</li>
<li data-path-to-node="4,1,0">Tunnel construction projects</li>
</ul>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Replacement Filter: </b>Alpha Ring Filter BLA-6</p>
<h3 data-path-to-node="5"><b data-path-to-node="1" data-index-in-node="0">Sakai Type</b> <b data-path-to-node="1" data-index-in-node="11">BL-200H-02</b></h3>
<p>Includes battery &amp; charger. Pattern Test Cert No. TP13</p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56606" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-20_103438-removebg-preview.png" alt="" width="242" height="289" /></p>
<ul>
<li data-path-to-node="2,0,0">PL3</li>
<li data-path-to-node="2,1,0">Class S</li>
<li data-path-to-node="2,2,0">Assigned Protection Factor: 300 (※)</li>
</ul>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Applications:</b></p>
<ul>
<li data-path-to-node="4,0,0">Asbestos removal</li>
<li data-path-to-node="4,1,0">Indium handling</li>
<li data-path-to-node="4,2,0">RCF handling</li>
<li data-path-to-node="4,3,0">Dioxin (Level 1)</li>
</ul>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Replacement Filter: </b>Alpha Ring Filter BRD-7</p>
<p data-path-to-node="5">※ SWPF (Simulated Workplace Protection Factor) measurement results conducted by our company demonstrate that the protection factor exceeds 300.</p>
<h3 data-path-to-node="5"><b data-path-to-node="1" data-index-in-node="0">Sakai Type</b> <b data-path-to-node="1" data-index-in-node="11">BL-200U-02</b></h3>
<p>Includes battery &amp; charger. Pattern Test Cert No. TP17</p>
<p><img loading="lazy" decoding="async" class=" wp-image-191662 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/3-1-300x200.png" alt="" width="408" height="272" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/3-1-300x200.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-1-1024x683.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-1-768x512.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-1.png 1536w" sizes="auto, (max-width: 408px) 100vw, 408px" /></p>
<ul>
<li data-path-to-node="2,0,0">PL3</li>
<li data-path-to-node="2,1,0">Class S</li>
<li data-path-to-node="2,2,0">Assigned Protection Factor: 300 (※)</li>
</ul>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Applications: </b>Nanomaterial handling</p>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Replacement Filter: </b>Alpha Ring Filter BRD-8U</p>
<p data-path-to-node="5">※ SWPF (Simulated Workplace Protection Factor) measurement results conducted by our company demonstrate that the protection factor exceeds 300.</p>
<h3>Performance Specifications</h3>
<table class="spec-table">
<thead>
<tr>
<th rowspan="2"><strong>Model</strong></th>
<th colspan="3"><strong>Classification</strong></th>
<th rowspan="2"><strong>Capture Efficiency</strong></th>
<th rowspan="2"><strong>Weight (incl. battery)</strong></th>
<th rowspan="2"><strong>Facepiece Weight</strong></th>
<th rowspan="2"><strong>Battery Specs</strong></th>
<th rowspan="2"><strong>Nominal Runtime*1</strong></th>
<th rowspan="2"><strong>Actual Runtime*2</strong></th>
<th rowspan="2"><strong>Fan Lifespan</strong></th>
</tr>
<tr>
<th><strong>Fan Type</strong></th>
<th><strong>Leakage Rate</strong></th>
<th><strong>Filter Class</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td class="product">BL-711H</td>
<td rowspan="4">High Flow Rate</td>
<td rowspan="4">Class S (≤0.1%)</td>
<td rowspan="4">PL3</td>
<td>99.97% or more</td>
<td colspan="2">≤753g (Avg 723g)</td>
<td class="left" rowspan="4">Rechargeable Li-ion<br />
Rated Voltage: 7.2V<br />
Rated Capacity: 2000mAh<br />
Charge time: approx 3 hours*3<br />
Charge cycles: approx 300*3</td>
<td rowspan="2">Approx 6 hours</td>
<td rowspan="2">Approx 6.5–10 hours</td>
<td rowspan="20">Approx 2,000 hours*3</td>
</tr>
<tr>
<td class="product">BL-711U</td>
<td>99.99% or more</td>
<td colspan="2">≤753g (Avg 720g)</td>
</tr>
<tr>
<td class="product">BL-700HA</td>
<td>99.97% or more</td>
<td rowspan="2">≤774g</td>
<td rowspan="2">Avg 591g</td>
<td rowspan="2">Approx 7.5 hours</td>
<td rowspan="2">Approx 8–14.5 hours</td>
</tr>
<tr>
<td class="product">BL-700U</td>
<td>99.99% or more</td>
</tr>
<tr>
<td class="product">BL-7005<br />
BL-7005AL</td>
<td rowspan="3">Standard Flow Rate</td>
<td rowspan="3">Class A (≤1.0%)</td>
<td>PL2</td>
<td>99.0% or more</td>
<td colspan="2">≤298g (Avg 288g)</td>
<td rowspan="5">Rechargeable Li-ion<br />
Rated Voltage: 3.7V<br />
Rated Capacity: 1100mAh<br />
Charge time: approx 3 hours*3<br />
Charge cycles: approx 300*3</td>
<td>Approx 6.7 hours</td>
<td>Approx 4–9 hours</td>
</tr>
<tr>
<td class="product">BL-1005<br />
BL-1005AL</td>
<td rowspan="3">PL1</td>
<td>95.0% or more</td>
<td colspan="2">≤278g (Avg 271g)</td>
<td rowspan="2">Approx 8.5 hours</td>
<td rowspan="2">Approx 3.5–11 hours</td>
</tr>
<tr>
<td class="product">BL-1005X<br />
BL-1005XAL</td>
<td>95.0% or more</td>
<td colspan="2">≤285g (Avg 278g)</td>
</tr>
<tr>
<td class="product">BL-321S</td>
<td rowspan="13">High Flow Rate</td>
<td>Class B (≤5.0%)</td>
<td>95.0% or more</td>
<td colspan="2">≤252g (Avg 244g)</td>
<td>Approx 3.5 hours</td>
<td>Approx 5–9 hours</td>
</tr>
<tr>
<td class="product">BL-321H</td>
<td>Class S (≤0.1%)</td>
<td>PL3</td>
<td>99.97% or more</td>
<td colspan="2">≤265g (Avg 257g)</td>
<td>Approx 3 hours</td>
<td>Approx 3–6 hours</td>
</tr>
<tr>
<td class="product">BL-351S</td>
<td>Class B (≤5.0%)</td>
<td>PL1</td>
<td>95.0% or more</td>
<td colspan="2">Avg 315g</td>
<td rowspan="11">Rechargeable Li-ion<br />
Rated Voltage: 7.2V<br />
Rated Capacity: 2000mAh<br />
Charge time: approx 3 hours*3<br />
Charge cycles: approx 300*3</td>
<td>Approx 10 hours</td>
<td>Approx 13–22 hours</td>
</tr>
<tr>
<td class="product">BL-351H</td>
<td rowspan="3">Class S (≤0.1%)</td>
<td rowspan="3">PL3</td>
<td>99.97% or more</td>
<td colspan="2" rowspan="2">Avg 328g</td>
<td rowspan="3">Approx 9 hours</td>
<td rowspan="3">Approx 8–17 hours</td>
</tr>
<tr>
<td class="product">BL-351U</td>
<td>99.99% or more</td>
</tr>
<tr>
<td class="product">BL-351HX</td>
<td>99.97% or more</td>
<td colspan="2">Avg 333g</td>
</tr>
<tr>
<td class="product">BL-200S</td>
<td>Class B (≤5.0%)</td>
<td>PL1</td>
<td>95.0% or more</td>
<td>≤395g</td>
<td>Avg 219g</td>
<td>Approx 10.5 hours</td>
<td>Approx 12–22 hours</td>
</tr>
<tr>
<td class="product">BL-200H</td>
<td rowspan="2">Class S (≤0.1%)</td>
<td rowspan="2">PL3</td>
<td>99.97% or more</td>
<td rowspan="2">≤409g</td>
<td rowspan="2">Avg 234g</td>
<td rowspan="2">Approx 9.5 hours</td>
<td rowspan="2">Approx 10–18 hours</td>
</tr>
<tr>
<td class="product">BL-200U</td>
<td>99.99% or more</td>
</tr>
<tr>
<td class="product">BL-100S</td>
<td rowspan="2">Class B (≤5.0%)</td>
<td rowspan="2">PL1</td>
<td rowspan="2">95.0% or more</td>
<td rowspan="2">≤383g</td>
<td rowspan="2">Avg 206g</td>
<td rowspan="2">Approx 10 hours</td>
<td rowspan="2">Approx 12–22 hours</td>
</tr>
<tr>
<td class="product">BL-100SC</td>
</tr>
<tr>
<td class="product">BL-100H</td>
<td rowspan="2">Class S (≤0.1%)</td>
<td rowspan="2">PL3</td>
<td>99.97% or more</td>
<td rowspan="2">≤397g</td>
<td rowspan="2">Avg 222g</td>
<td rowspan="2">Approx 9 hours</td>
<td rowspan="2">Approx 10–18 hours</td>
</tr>
<tr>
<td class="product">BL-100U</td>
<td>99.99% or more</td>
</tr>
</tbody>
</table>
<div class="note">
<div>*1 Calculated duration for maintaining positive pressure inside the facepiece under standard indoor conditions per respiratory protection standards.</div>
<div>*2 Observed duration for maintaining positive pressure in dusty environments, based on actual worker respiratory data during field work.</div>
<div>*3 May vary or be shorter depending on actual usage conditions.</div>
</div>
<h3>Replacement Filters</h3>
<table>
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56599" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_155832-removebg-preview.png" alt="" width="201" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56598" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_155838-removebg-preview.png" alt="" width="200" height="128" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56597" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_155847-removebg-preview.png" alt="" width="177" height="129" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56600" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-155854.png" alt="" width="182" height="133" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56594" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-155741.png" alt="" width="174" height="126" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56595" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-155749.png" alt="" width="164" height="130" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56596" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-155757.png" alt="" width="182" height="131" /></td>
</tr>
<tr>
<td height="19"><strong>Alpha Ring Filter BRD-82</strong> Screw-on type</td>
<td><strong>Alpha Ring Filter BRD-82U</strong> Screw-on type</td>
<td><strong>Alpha Ring Filter BLA-62</strong> Screw-on type</td>
<td><strong>Alpha Ring Filter BRD-7</strong></td>
<td><strong>Alpha Ring Filter BRD-8U</strong></td>
<td><strong>Alpha Ring Filter BLA-6</strong></td>
<td><strong>Alpha Ring Filter BLA-6C</strong></td>
</tr>
</tbody>
</table>
<p>● When performing tasks such as welding or grinding where sparks or spatter are generated, it is mandatory to install the dedicated inhalation port cover (sold separately) on the filter (except for the BL-7005 and BL-1005 series). Note that the BL-700HA/U, BL-200H/U, and BL-100H/U series must not be used in environments where sparks or spatter are present.</p>
<h3>Key Features:</h3>
<ul>
<li data-path-to-node="2,0,0"><b data-path-to-node="2,0,0" data-index-in-node="0">High Synchro:</b> Next-generation model improves airflow efficiency and accurately tracks the user&#8217;s breathing rhythm.</li>
<li data-path-to-node="2,1,0"><b data-path-to-node="2,1,0" data-index-in-node="0">Fit Checker:</b> A fit test can be easily performed simply by pulling the lever.</li>
<li data-path-to-node="2,2,0"><b data-path-to-node="2,2,0" data-index-in-node="0">Under Chin:</b> Unique curved design enhances the seal at the face contact area.</li>
<li data-path-to-node="2,3,0"><b data-path-to-node="2,3,0" data-index-in-node="0">Micron:</b> High-performance electrostatic filter. This mask utilizes the advanced Micron filter technology.</li>
<li data-path-to-node="2,4,0"><b data-path-to-node="2,4,0" data-index-in-node="0">Speaker:</b> Integrated small communication speaker makes conversation clearer.</li>
<li data-path-to-node="2,5,0"><b data-path-to-node="2,5,0" data-index-in-node="0">Special Hard Coating:</b> Thanks to a special coating, scratch resistance is significantly improved compared to standard surface hardening methods.</li>
<li data-path-to-node="2,6,0"><b data-path-to-node="2,6,0" data-index-in-node="0">Silicone:</b> The facepiece uses medical-grade silicone material, providing a soft wearing feel that is gentle on the skin.</li>
<li data-path-to-node="2,7,0"><b data-path-to-node="2,7,0" data-index-in-node="0">Speaking Diaphragm:</b> Equipped with a speaking diaphragm, allowing conversation or instructions without removing the mask.</li>
<li data-path-to-node="2,8,0"><b data-path-to-node="2,8,0" data-index-in-node="0">Internal Pressure Monitoring:</b> A warning light flashes when positive pressure is no longer maintained inside the mask.</li>
<li data-path-to-node="2,9,0"><b data-path-to-node="2,9,0" data-index-in-node="0">HAWC Lip:</b> Full-face models apply HAWC Lip technology, achieving a high seal through a &#8220;suction cup effect.&#8221;</li>
<li data-path-to-node="2,10,0"><b data-path-to-node="2,10,0" data-index-in-node="0">Surface Hardening:</b> The eyepiece is treated with a hardening process to resist scratches.</li>
</ul>The post <a href="https://koueitrading.com/global/product/koken-bl-200-series-p-papr/">Koken BL-200 Series P-PAPR</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken BL-100 Series P-PAPR</title>
		<link>https://koueitrading.com/global/product/koken-bl-100-series-p-papr/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Wed, 04 Mar 2020 06:44:37 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=191658</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: BL-100 Series P-PAPR: Powered Air-Purifying Particulate Respirator PARTICULATE PAPR and GAS PAPR PAPR: Powered Air-Purifying Respirator. P-PAPR: Particulate PAPR (Used for dust/particles). G-PAPR: Gas PAPR (Used for toxic gases/vapors). Within the PAPR range, there are “Powered Air-Purifying Particulate Respirators (P-PAPR)” for dust hazards and “Powered Air-Purifying Gas Respirators (G-PAPR)” for toxic [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-bl-100-series-p-papr/">Koken BL-100 Series P-PAPR</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: BL-100 Series</p>
<p>P-PAPR: Powered Air-Purifying Particulate Respirator</p>
<h2>PARTICULATE PAPR and GAS PAPR</h2>
<ul>
<li data-path-to-node="14,0,0">PAPR: Powered Air-Purifying Respirator.</li>
<li data-path-to-node="14,1,0">P-PAPR: Particulate PAPR (Used for dust/particles).</li>
<li data-path-to-node="14,2,0">G-PAPR: Gas PAPR (Used for toxic gases/vapors).</li>
</ul>
<p data-path-to-node="3">Within the PAPR range, there are “Powered Air-Purifying Particulate Respirators (P-PAPR)” for dust hazards and “Powered Air-Purifying Gas Respirators (G-PAPR)” for toxic gas hazards. It is essential to understand the properties, type, and concentration of the hazardous substances before selecting the appropriate mask.</p>
<p data-path-to-node="3">To prevent inhalation of DUST -&gt; Use a Powered Air-Purifying Particulate Respirator (P-PAPR)<br />
To prevent inhalation of TOXIC GAS -&gt; Use a Powered Air-Purifying Gas Respirator (G-PAPR)<br />
To prevent inhalation of MIXED DUST &amp; TOXIC GAS -&gt; Use a Powered Air-Purifying Gas Respirator (G-PAPR) with dust protection function</p>
<h3>Environments where PAPR CANNOT be used</h3>
<p data-path-to-node="9">PAPR must not be used if any of the following conditions apply. Please use respiratory protective equipment suitable for the environment, such as a supplied-air respirator or a self-contained breathing apparatus (SCBA).</p>
<ul>
<li data-path-to-node="10,0,0">Oxygen-deficient environments or those at risk of oxygen deficiency (Oxygen concentration below 18%).</li>
<li data-path-to-node="10,1,0">Cases where the type or concentration of the toxic gas is unknown.</li>
<li data-path-to-node="10,2,0">IDLH environments (Atmospheres Immediately Dangerous to Life or Health).</li>
<li data-path-to-node="10,2,0">Cases where the toxic gas concentration exceeds the permissible limit for the PAPR. ※</li>
<li data-path-to-node="10,3,0">Cases where no filter (canister) is available to remove the specific toxic gas in the environment.</li>
<li data-path-to-node="10,4,0">Cases where a mixture of gases with different properties exists.</li>
<li data-path-to-node="10,5,0">Cases where the environment deviates significantly from normal temperature, humidity, and atmospheric pressure.</li>
</ul>
<p data-path-to-node="11">(※ According to standards based on the Industrial Safety and Health Act, the application range of G-PAPR is 2% (3% for Ammonia))</p>
<h3>SELECTING THE APPROPRIATE PAPR BASED ON HAZARD CONCENTRATION</h3>
<p data-path-to-node="3">Determine the Required Protection Factor, then select a PAPR model with an Assigned Protection Factor higher than that value.</p>
<p data-path-to-node="4,0">Formula: How to calculate the Required Protection Factor<br />
<strong>Required Protection Factor = Ambient concentration of identified hazard / Permissible exposure limit of the hazard</strong></p>
<p>Assigned Protection Factor of P-PAPR</p>
<table>
<thead>
<tr>
<th colspan="2"><strong>Classification</strong></th>
<th colspan="4"><strong>Facepiece Type</strong></th>
</tr>
<tr>
<th><strong>Leakage Rate</strong></th>
<th><strong>Filter Efficiency</strong></th>
<th><strong>Half-face</strong></th>
<th><strong>Full-face</strong></th>
<th><strong>Hood Type</strong></th>
<th><strong>Face shield</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td rowspan="3">Class S</td>
<td>PL3/PS3</td>
<td>50/300</td>
<td>1000</td>
<td>25/1000</td>
<td>25/300</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>—</td>
<td>—</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td rowspan="3">Class A</td>
<td>PL3/PS3</td>
<td>—</td>
<td>—</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>33</td>
<td>90</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>14</td>
<td>19</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td rowspan="3">Class B</td>
<td>PL3/PS3</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>14</td>
<td>19</td>
<td>11</td>
<td>11</td>
</tr>
</tbody>
</table>
<p>Assigned Protection Factor of G-PAPR</p>
<table>
<thead>
<tr>
<th class="header-main" colspan="4"><strong>Facepiece Type</strong></th>
</tr>
<tr>
<th><strong>Half-face</strong></th>
<th><strong>Full-face</strong></th>
<th><strong>Hood Type</strong></th>
<th><strong>Face shield</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>50/300</td>
<td>1000</td>
<td>25/1000</td>
<td>25/300</td>
</tr>
</tbody>
</table>
<p>For “G-PAPR with dust protection function,” please refer to the Assigned Protection Factor of P-PAPR (Class S leakage rate) mentioned above for dust (and similar particulates).</p>
<h2>TASKS WHERE PAPR USE IS MANDATORY BY REGULATION OR DIRECTIVE</h2>
<p><strong>For tasks where PAPR use is mandatory by regulation or directive, please use a PAPR with the designated performance classification.</strong></p>
<h4><strong>1. Tunnel Construction Work</strong></h4>
<p><strong>Regulation:</strong> “Ordinance on Prevention of Pneumoconiosis”<br />
<strong>Scope:</strong> In tunnel construction, at locations involving “mechanical/powered excavation,” “mechanical loading or unloading of ore/rock,” and “shotcreting.”</p>
<p><strong>PAPR Requirements:</strong></p>
<ul>
<li>National test certified product (High airflow type).</li>
<li>Tight-fitting facepiece type where the battery can be removed for use during blasting operations.</li>
</ul>
<h4><strong>2. Asbestos Removal Work</strong></h4>
<p><strong>Regulation:</strong> “Ordinance on Prevention of Health Impairment due to Asbestos”<br />
<strong>Scope</strong>: In asbestos removal tasks, specifically those requiring “Class 1 Asbestos Removal Masks.”<br />
<b data-path-to-node="11,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified tight-fitting or hood types (High airflow, Class S, PL3 or PS3).</p>
<h4 data-path-to-node="12"><b data-path-to-node="12" data-index-in-node="0">3. Handling Nanomaterials</b></h4>
<p data-path-to-node="13,0,0"><b data-path-to-node="13,0,0" data-index-in-node="0">Directive:</b> “Regarding Preventive Measures for Exposure to Nanomaterials”<br />
<b data-path-to-node="13,1,0" data-index-in-node="0">Scope:</b> Manufacturing and handling of nanomaterials. (※)<br />
<b data-path-to-node="13,2,0" data-index-in-node="0">PAPR Requirements:</b></p>
<ul>
<li data-path-to-node="13,2,0">National test certified product (High airflow, PL3 or PS3).</li>
<li data-path-to-node="13,2,1,0,0">Shape limitations based on the projected exposure levels of workers.</li>
</ul>
<p data-path-to-node="13,2,1,1,0">(※) Depending on the work environment, respiratory protective equipment other than PAPR may be used.</p>
<h4 data-path-to-node="14"><b data-path-to-node="14" data-index-in-node="0">4. Handling Indium</b></h4>
<p data-path-to-node="15,0,0"><b data-path-to-node="15,0,0" data-index-in-node="0">Directive:</b> “Regarding Thorough Health Hazard Prevention Measures for Indium/Tin Oxide Handling”<br />
<b data-path-to-node="15,1,0" data-index-in-node="0">Scope:</b> Handling of Indium, Tin Oxide, etc. (※)<br />
<b data-path-to-node="15,2,0" data-index-in-node="0">PAPR Requirements:</b></p>
<ul>
<li data-path-to-node="15,2,0">National test certified product (High airflow, PL3 or PS3).</li>
<li data-path-to-node="15,2,1,0,0">Limitations on shape and leakage rate based on working environment measurement results.</li>
</ul>
<p data-path-to-node="15,2,1,1,0">(※) Depending on environmental results, respiratory protective equipment other than PAPR may be used.</p>
<h4 data-path-to-node="16"><b data-path-to-node="16" data-index-in-node="0">5. Handling Dioxins</b></h4>
<p><b data-path-to-node="17,0,0" data-index-in-node="0">Directive:</b> “Revision of Guidelines for Dioxin Exposure Prevention in Waste Incineration Facilities”<br />
<b data-path-to-node="17,1,0" data-index-in-node="0">Scope:</b> For dioxin-exposure risk tasks classified as “Level 1.” (※)<br />
<b data-path-to-node="17,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified product (High airflow, PL3 or PS3).</p>
<p>(※) RL3 or RS3 dust masks may be used, but PAPR with higher protective performance is recommended.</p>
<h4 data-path-to-node="18"><b data-path-to-node="18" data-index-in-node="0">6. Handling Refractory Ceramic Fibers (RCF)</b></h4>
<p><b data-path-to-node="19,0,0" data-index-in-node="0">Regulation:</b> “Ordinance on Prevention of Hazards due to Specified Chemical Substances”<br />
<b data-path-to-node="19,1,0" data-index-in-node="0">Scope:</b> Insulation or fireproofing work involving the application of RCF to furnaces or boilers; or repair, dismantling, and demolition of such furnaces/boilers.<br />
<b data-path-to-node="19,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified product (PL3 or PS3).</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong>PAPR Standards</strong></th>
<td width="64">Beyond JIS standards, Powered Air-Purifying Respirators must adhere to standards defined under the Industrial Safety and Health Act. These comprehensive standards ensure that products are manufactured under strict safety requirements.</td>
</tr>
</tbody>
</table>
<p>The following table is excerpted from the ‘Standards for Powered Air-Purifying Respirators’</p>
<h3>Types of Powered Air-Purifying Respirators</h3>
<table>
<tbody>
<tr>
<th colspan="2"><strong>Powered Air-Purifying Particulate Respirator (P-PAPR)</strong></th>
</tr>
<tr>
<th rowspan="2"><strong>Powered Air-Purifying Gas Respirator (G-PAPR)</strong></th>
<td>Type with dust protection function</td>
</tr>
<tr>
<td>Type without dust protection function</td>
</tr>
</tbody>
</table>
<p><strong>■ Classification by Shape</strong></p>
<table>
<tbody>
<tr>
<th rowspan="2"><strong>Tight-fitting Facepiece</strong><br />
<span class="sub-item">・Full-face</span><br />
<span class="sub-item">・Half-face</span></th>
<td>Isolation type (with hose)</td>
</tr>
<tr>
<td>Direct connection type</td>
</tr>
<tr>
<th rowspan="2"><strong>Loose-fitting Facepiece</strong><br />
<span class="sub-item">・Hood</span><br />
<span class="sub-item">・Face shield</span></th>
<td>Isolation type (with hose)</td>
</tr>
<tr>
<td>Direct connection type</td>
</tr>
</tbody>
</table>
<p><strong>■ Classification by Performance</strong></p>
<table>
<thead>
<tr>
<th><strong>Airflow Performance Classification</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>Standard airflow type</td>
</tr>
<tr>
<td>High airflow type</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th><strong>Leakage Rate Performance Classification (P-PAPR)</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>Class B</td>
</tr>
<tr>
<td>Class A</td>
</tr>
<tr>
<td>Class S</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th colspan="2"><strong>Filter Material Performance Classification<br />
(P-PAPR and G-PAPR with dust function)</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td width="50%">PS1</td>
<td width="50%">PL1</td>
</tr>
<tr>
<td>PS2</td>
<td>PL2</td>
</tr>
<tr>
<td>PS3</td>
<td>PL3</td>
</tr>
</tbody>
</table>
<h3>Performance Testing for Powered Air-Purifying Respirators</h3>
<h4><strong>■ Particle Collection Efficiency Test</strong></h4>
<p>(Applies only to P-PAPR and G-PAPR with dust protection)</p>
<table>
<tbody>
<tr>
<th class="header-bg col-label" rowspan="3"><strong>Test Particle</strong></th>
<th class="header-bg col-sub"><strong>Type</strong></th>
<td class="align-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="align-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="header-bg"><strong>Particle Size</strong></th>
<td colspan="2">0.06μm ~ 0.1μm</td>
<td colspan="2">0.15μm ~ 0.25μm</td>
</tr>
<tr>
<th class="header-bg"><strong>Concentration</strong></th>
<td colspan="2">50mg/m³ or less</td>
<td colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="header-bg" rowspan="2"><strong>Test Flow Rate</strong></th>
<th class="header-bg"><strong>Standard Flow</strong></th>
<td colspan="4">104 L/min</td>
</tr>
<tr>
<th class="header-bg"><strong>High Flow</strong></th>
<td colspan="4">138 L/min</td>
</tr>
<tr>
<th class="header-bg align-left" colspan="2" rowspan="4"><strong>Collection Efficiency<br />
(Continuous measurement; must meet values in the right column)</strong></th>
<td colspan="2">For NaCl, loaded up to 200mg</td>
<td colspan="2">For DOP, loaded up to 400mg</td>
</tr>
<tr>
<td class="col-val">PS1</td>
<td class="col-res">95.0% or more</td>
<td class="col-val">PL1</td>
<td class="col-res">95.0% or more</td>
</tr>
<tr>
<td>PS2</td>
<td>99.0% or more</td>
<td>PL2</td>
<td>99.0% or more</td>
</tr>
<tr>
<td>PS3</td>
<td>99.97% or more</td>
<td>PL3</td>
<td>99.97% or more</td>
</tr>
</tbody>
</table>
<h4><strong>■ Canister Testing</strong></h4>
<p>(Applies only to G-PAPR)</p>
<table>
<tbody>
<tr>
<th><strong>Airtightness</strong></th>
<td class="align-left" colspan="4">No air leakage at 1470 Pa pressure</td>
</tr>
<tr>
<th rowspan="5"><strong>Decontamination Capacity<br />
(Time until breakthrough at specified concentration must be ≥ the right column)</strong></th>
<th><strong>Type</strong></th>
<th><strong>Test Gas</strong></th>
<th><strong>Breakthrough Concentration</strong></th>
<th><strong>Duration</strong></th>
</tr>
<tr>
<td>Halogen gas</td>
<td>Chlorine (0.02%)</td>
<td>1 ppm</td>
<td>40 mins or more</td>
</tr>
<tr>
<td>Organic gas</td>
<td>Cyclohexane (0.03%)</td>
<td>5 ppm</td>
<td>50 mins or more</td>
</tr>
<tr>
<td>Ammonia</td>
<td>Ammonia (0.1%)</td>
<td>50 ppm</td>
<td>40 mins or more</td>
</tr>
<tr>
<td>SO₂ gas</td>
<td>Sulfur dioxide (0.03%)</td>
<td>5 ppm</td>
<td>35 mins or more</td>
</tr>
<tr>
<th><strong>Leakage Concentration</strong></th>
<td class="align-left" colspan="4">At maximum flow rate, time to reach breakthrough must be ≥ 3 minutes.</td>
</tr>
</tbody>
</table>
<h4><strong>■ Inward Leakage Rate Test</strong></h4>
<table>
<colgroup>
<col />
<col />
<col />
<col /></colgroup>
<tbody>
<tr>
<th rowspan="3"><strong>Test Particle</strong></th>
<th><strong>Type</strong></th>
<td colspan="4">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<th><strong>Particle Size</strong></th>
<td colspan="4">0.06μm ~ 0.2μm</td>
</tr>
<tr>
<th><strong>Concentration</strong></th>
<td colspan="4">18mg/m³ or less</td>
</tr>
<tr>
<th rowspan="4"><strong>Simulated Breathing</strong></th>
<th><strong>Type</strong></th>
<td colspan="2">Standard Flow</td>
<td colspan="2">High Flow</td>
</tr>
<tr>
<th><strong>Waveform</strong></th>
<td colspan="4">Sine wave</td>
</tr>
<tr>
<th><strong>Ventilation Volume</strong></th>
<td colspan="2">1.5 ± 0.075 L/stroke</td>
<td colspan="2">1.6 ± 0.08 L/stroke</td>
</tr>
<tr>
<th><strong>Frequency</strong></th>
<td colspan="2">20 times/min</td>
<td colspan="2">25 times/min</td>
</tr>
<tr>
<th colspan="2" rowspan="4"><strong>Leakage Rate<br />
(2-minute continuous measurement; max value must meet the right column)</strong></th>
<td rowspan="3">P-PAPR</td>
<td>Class B</td>
<td colspan="2">5.0% or less</td>
</tr>
<tr>
<td>Class A</td>
<td colspan="2">1.0% or less</td>
</tr>
<tr>
<td>Class S</td>
<td colspan="2">0.1% or less</td>
</tr>
<tr>
<td>G-PAPR</td>
<td colspan="3">0.1% or less</td>
</tr>
<tr>
<th colspan="2" rowspan="4"><strong>Headform Movement<br />
(Calculate leakage rate for each item)</strong></th>
<th colspan="3"><strong>Position and Range</strong></th>
<th><strong>Frequency</strong></th>
</tr>
<tr>
<td rowspan="2">Head</td>
<td colspan="2">Front/Back 30 degrees</td>
<td>17 times/min</td>
</tr>
<tr>
<td colspan="2">Left/Right rotation 50 degrees</td>
<td>11 times/min</td>
</tr>
<tr>
<td>Arms</td>
<td colspan="2">Raising 10 ~ 130 degrees</td>
<td>7 times/min</td>
</tr>
</tbody>
</table>
<h4><strong>■ Other Tests</strong></h4>
<table>
<tbody>
<tr>
<th><strong>Internal Pressure<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">Under simulated breathing identical to the leakage test:<br />
0 Pa &lt; Internal Mask Pressure &lt; 400 Pa</td>
</tr>
<tr>
<th rowspan="2"><strong>Minimum Required Flow<br />
(Loose-fit only)</strong></th>
<td class="align-center">Standard Flow</td>
<td class="align-center">104 L/min or more</td>
</tr>
<tr>
<td class="align-center">High Flow</td>
<td class="align-center">138 L/min or more</td>
</tr>
<tr>
<th><strong>Inhalation Resistance<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">160 Pa or less<br />
(40 L/min flow rate, fan OFF)</td>
</tr>
<tr>
<th><strong>Exhalation Resistance<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">80 Pa or less<br />
(40 L/min flow rate, fan OFF)</td>
</tr>
<tr>
<th><strong>Exhalation Valve Airtightness<br />
(Tight-fitting only)</strong></th>
<td class="content-cell" colspan="2">・Internal pressure must drop immediately when air is sucked.<br />
・Time for pressure to return to normal must be ≥ 15 seconds.</td>
</tr>
<tr>
<th><strong>CO2 Concentration Increase<br />
(Tight-fitting only)</strong></th>
<td class="content-cell" colspan="2">With fan OFF, headform breathes CO2 air. Difference between wearing and not wearing mask must be &lt; 2.0%.</td>
</tr>
<tr>
<th><strong>Noise Level</strong></th>
<td class="align-center" colspan="2">Noise at the headform ear area must be below 80 dB (both sides).</td>
</tr>
<tr>
<th rowspan="4"><strong>Flow Rate<br />
(G-PAPR only)</strong></th>
<td>Max set average flow</td>
<td class="content-cell">Average must be ≤ the decontamination test flow rate.</td>
</tr>
<tr>
<td>Maximum flow</td>
<td class="content-cell">Maximum must be ≤ the flow rate set by the manufacturer.</td>
</tr>
<tr>
<th><strong>Tight-fitting type</strong></th>
<th><strong>Loose-fitting type</strong></th>
</tr>
<tr>
<td class="content-cell">Measure resistance with fan OFF/ON at 20~170 L/min to calculate flow per minute.</td>
<td class="content-cell">With fan ON, draw air for 5 mins to maintain normal pressure in chamber, then measure flow.</td>
</tr>
</tbody>
</table>
<h2>PAPR USE IS ENCOURAGED IN THE 10TH COMPREHENSIVE DUST HAZARD COUNTERMEASURES</h2>
<p><strong>To reduce pneumoconiosis, dust prevention measures must be strengthened.</strong></p>
<p>The “10th Comprehensive Countermeasures for Preventing Dust Hazards” demands the correct use of effective respiratory protection against dust exposure across all industries. PAPR is highlighted as a “more effective preventive measure for health impairment,” and its adoption is highly encouraged.<br />
The use of PAPR is more effective in preventing health impairment compared to standard dust masks due to its higher protection factor and reduced physical strain on the wearer.<br />
(Partial excerpt from the 10th Comprehensive Countermeasures)</p>
<p>Furthermore, due to high performance, PAPR is mandatory for specific tasks, but its use is also recommended for tasks outside the mandatory categories.<br />
While PAPR is mandatory for specific operations under the Dust Rules, its high performance makes it desirable for other tasks; thus, guidance and inspections encourage businesses to adopt PAPR for their workers.<br />
(Partial excerpt from the 10th Comprehensive Countermeasures)</p>
<h2>KOKEN BL SERIES BREATH-RESPONSIVE PAPR</h2>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Achieving “High Safety” and “Comfortable Fit” as expected</b></p>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">THE EVOLUTION OF THE BL SERIES</b></p>
<p data-path-to-node="6">The BL Series continues to evolve into the PAPR model that helps perfect safety and health management in every field, aligning with occupational health trends and market expansion.</p>
<p data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">CORE DEVELOPMENT FOCUS</b></p>
<ul>
<li data-path-to-node="8,0,0"><b data-path-to-node="8,0,0" data-index-in-node="0">“Safety”:</b> Improving the protection capability as a respirator.</li>
<li data-path-to-node="8,1,0"><b data-path-to-node="8,1,0" data-index-in-node="0">“Flow Technology”:</b> Minimizing waste and improving efficiency.</li>
<li data-path-to-node="8,2,0"><b data-path-to-node="8,2,0" data-index-in-node="0">“Lightweight Design”:</b> Reducing the burden on the worker.</li>
</ul>
<h2>KOKEN FLOW TECHNOLOGY: New BSFS air flow highly synchronized with breathing</h2>
<h3>THE MECHANISM OF THE BSFS (BREATH SYNCHRONIZED) SYSTEM</h3>
<p data-path-to-node="5">The BL Series is equipped with the Breath Synchronized-Air Flow System (new BSFS), which delivers airflow that follows the breathing rhythm more closely than ever, becoming a “Highly Synchronized” model.<br />
BSFS ELIMINATES THE FEELING OF BREATHLESSNESS/STUFFINESS<br />
<img loading="lazy" decoding="async" class="size-medium wp-image-191639 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-300x177.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-300x177.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4.jpg 464w" alt="" width="300" height="177" /></p>
<p><b data-path-to-node="2" data-index-in-node="0">THE BSFS MECHANISM HAS EVOLVED INTO “HIGH SYNCHRONIZATION”</b></p>
<p data-path-to-node="3">Using a fan equipped with a breath detection sensor, the device supplies “the necessary and sufficient amount of air” corresponding to the user’s inhalation. Responsiveness to breathing has been improved, and the accuracy of synchronization with the respiratory rhythm has significantly increased.<br />
<img loading="lazy" decoding="async" class="size-medium wp-image-191638 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-300x286.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-300x286.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-768x733.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1.jpg 1024w" alt="" width="300" height="286" /></p>
<h3>COMFORT UP</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">SOLVING MASK DISCOMFORT WITH FLOW THAT FOLLOWS EVERY BREATH</b></p>
<ul>
<li data-path-to-node="4,0,0">Reduces the physical workload for laborers.</li>
<li data-path-to-node="4,1,0">Solves breathing difficulties and stuffiness in high-temperature workplaces.</li>
</ul>
<h3>SAFETY UP</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">PREVENTING INWARD LEAKAGE THROUGH HIGH PROTECTION AND CONSTANT POSITIVE PRESSURE</b></p>
<p data-path-to-node="4,0,0">Breath Synchronization: Protection is guaranteed by the blower linked to breathing.</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class=" wp-image-191633 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-300x227.jpg" sizes="auto, (max-width: 441px) 100vw, 441px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-300x227.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-768x581.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6.jpg 1024w" alt="" width="441" height="334" /></td>
<td width="64"><img loading="lazy" decoding="async" class=" wp-image-191636 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-300x218.png" sizes="auto, (max-width: 508px) 100vw, 508px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-300x218.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-1024x745.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-768x559.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185.png 1407w" alt="" width="508" height="369" /></td>
</tr>
<tr>
<td height="19">
<p data-path-to-node="3,0,0"><b data-path-to-node="3,0,0" data-index-in-node="0">DURING INHALATION:</b> Air inside the mask is normally sucked away, but supplemental airflow prevents negative pressure. (If a gap exists, air blows outward ※1)</p>
<p data-path-to-node="3,0,0">※1: Airflow varies based on facepiece fit.</p>
</td>
<td>
<p data-path-to-node="3,1,0"><b data-path-to-node="3,1,0" data-index-in-node="0">DURING EXHALATION:</b> Since pressure doesn’t drop, airflow is reduced. This conserves the “filter” and “battery.”</p>
<p data-path-to-node="3,1,0">※2: Flow doesn’t stop completely (maintains a small amount for safety).</p>
</td>
</tr>
</tbody>
</table>
<p><b data-path-to-node="2" data-index-in-node="0">PAPR AVOIDS HIGH LEAKAGE RISKS FROM DUST BUILDUP IN LOOSE MASKS</b></p>
<p data-path-to-node="3">FOR CONVENTIONAL DUST MASKS:</p>
<p data-path-to-node="4">As dust builds on the filter, inhalation resistance increases, raising the risk of inward leakage. As dust accumulates, even if the gap remains the same, the leakage rate can double. (See diagram below)</p>
<p><img loading="lazy" decoding="async" class=" wp-image-191632 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-300x195.jpg" sizes="auto, (max-width: 409px) 100vw, 409px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-300x195.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-768x500.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-180x118.jpg 180w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8.jpg 1024w" alt="" width="409" height="266" /></p>
<p><b data-path-to-node="7" data-index-in-node="0">Leakage Measurement Method:</b> A 2.5% gap is created intentionally; NaCl concentration is measured inside/outside the mask with a digital meter.</p>
<h3>ECONOMY UP (ECO)</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">ELIMINATING WASTE THROUGH AN ECO FLOW MECHANISM</b></p>
<p data-path-to-node="4,0,0">Limits “wasteful dust buildup” and reduces filter usage: Minimizes air loss to reduce clogging.<br />
Limits battery usage: Extends runtime by reducing power consumption during low-respiration phases.</p>
<p><b data-path-to-node="2" data-index-in-node="0">BATTERY RUNTIME COMPARISON: NEW VS OLD BSFS</b></p>
<p data-path-to-node="3"><img loading="lazy" decoding="async" class=" wp-image-191631 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/1-300x126.png" sizes="auto, (max-width: 445px) 100vw, 445px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/1-300x126.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-1024x429.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-768x322.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/1.png 1536w" alt="" width="445" height="187" /></p>
<p data-path-to-node="3"><strong>ECO FLOW CREATED BY HIGH SYNCHRONIZATION</strong></p>
<p data-path-to-node="3"><img loading="lazy" decoding="async" class=" wp-image-191630 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/2-300x175.png" sizes="auto, (max-width: 456px) 100vw, 456px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/2-300x175.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-1024x599.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-768x449.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/2.png 1536w" alt="" width="456" height="266" />Image of BSFS flow following actual respiratory waveforms with high precision.</p>
<h2 data-path-to-node="3">KOKEN LIGHTWEIGHT DESIGN: Reducing burden for long shifts</h2>
<p>The “BL Series” optimizes compact sizing and weight equivalent to conventional dust masks. It is highly rated in tunnel construction, asbestos handling, and arc welding.</p>
<p><b data-path-to-node="4" data-index-in-node="0">SEPARATE TYPE</b> Because a direct-mounted battery adds weight to the neck, the separate design reduces perceived weight. This ultra-lightweight design minimizes mask body thickness.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56541" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-122956.png" alt="" width="348" height="302" /></p>
<p><b data-path-to-node="5" data-index-in-node="0">BUILT-IN TYPE</b> Thanks to “High Synchro” BSFS reducing power draw, battery size has been shrunk. This results in a lightweight built-in battery design with minimal burden.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56542" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123026.png" alt="" width="212" height="269" /></p>
<h2>KOKEN SAFETY DESIGN: Internal pressure monitoring to maintain positive pressure</h2>
<p data-path-to-node="3">(Common for BL-321/BL-351/BL-351X/BL-711/BL-700/BL-200/BL-100 series)</p>
<p data-path-to-node="4">Modern worksites require PAPRs that “constantly monitor internal pressure and provide alerts.”<br />
PAPR is most protective under positive pressure; therefore, the moment positive pressure cannot be maintained is the filter replacement time. “Internal monitoring” notifies the user when pressure drops due to weak flow.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56543" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123245.png" alt="" width="243" height="253" /></p>
<p data-path-to-node="7,0,0">■ Positive pressure inside the mask can be maintained through timely/appropriate filter replacement.<br />
■ Clarifies the standard for filter replacement – which is otherwise often vague or based on subjective estimation.<br />
■ Full airflow can be restored through proper battery charging.</p>
<p><b data-path-to-node="2" data-index-in-node="0">NOTIFICATION VIA AIRFLOW</b></p>
<p data-path-to-node="3">(For BL-321 / BL-351 / BL-351X / BL-711 series)</p>
<ul>
<li data-path-to-node="4,0,0">Pressure drop warning via “Continuous Airflow”: ➔ Replace the filter.</li>
<li data-path-to-node="4,1,0">Low battery warning via “Rhythmic Airflow”: ➔ Replace with a charged battery.</li>
</ul>
<p><b data-path-to-node="6" data-index-in-node="0">LED NOTIFICATION</b></p>
<p data-path-to-node="7">(For BL-700 / BL-200 / BL-100 series)</p>
<ul>
<li data-path-to-node="8,0,0">Pressure drop warning via “Flashing LED”: ➔ Replace the filter.</li>
<li data-path-to-node="8,1,0">Low battery warning via “Steady LED”: ➔ Replace with a charged battery.</li>
</ul>
<p><img loading="lazy" decoding="async" class=" wp-image-191629 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/3-300x65.png" sizes="auto, (max-width: 471px) 100vw, 471px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/3-300x65.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-1024x221.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-768x166.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/3.png 1536w" alt="" width="471" height="102" /></p>
<h2>POWERED AIR-PURIFYING PARTICULATE RESPIRATOR (P-PAPR)</h2>
<p>Note: Variation images for BL-200/BL-100 series only show the main body.</p>
<h3>BL-100 SERIES</h3>
<p>Separate battery type for a lighter facepiece experience.</p>
<p data-path-to-node="4,0,0"><b data-path-to-node="4,0,0" data-index-in-node="0">Classification:</b> <b data-path-to-node="4,0,0" data-index-in-node="11">HIGH AIRFLOW TYPE</b></p>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Key Features:</b></p>
<ul>
<li data-path-to-node="6,0,0">High Synchro</li>
<li data-path-to-node="6,1,0">Internal Pressure Monitoring</li>
<li data-path-to-node="6,2,0">Under Chin Design</li>
<li data-path-to-node="6,3,0">Silicone Material</li>
</ul>
<h4 data-path-to-node="1"><b data-path-to-node="1" data-index-in-node="0">BL-100S, BL-100SC</b></h4>
<p data-path-to-node="2">Shared Facepiece Body (※1)</p>
<p data-path-to-node="3,0,0">Adaptable by changing the filter based on the application.</p>
<ul>
<li data-path-to-node="3,0,1,0,0">Install BLA-6 for BL-100S</li>
<li data-path-to-node="3,0,1,1,0">Install BLA-6C for BL-100SC</li>
</ul>
<p data-path-to-node="1,0,0">■ Constant positive pressure management via internal monitoring.</p>
<p data-path-to-node="1,0,0"><img loading="lazy" decoding="async" class="size-medium wp-image-191654 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/7237c887-4a81-4077-a69a-9373ed49a1ae-300x200.png" alt="" width="300" height="200" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/7237c887-4a81-4077-a69a-9373ed49a1ae-300x200.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/7237c887-4a81-4077-a69a-9373ed49a1ae-1024x683.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/7237c887-4a81-4077-a69a-9373ed49a1ae-768x512.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/7237c887-4a81-4077-a69a-9373ed49a1ae.png 1536w" sizes="auto, (max-width: 300px) 100vw, 300px" /></p>
<p data-path-to-node="1,1,0">■ Dedicated hood (sold separately) allows use with standard eyewear.</p>
<h3 data-path-to-node="1,1,0"><b data-path-to-node="1" data-index-in-node="0">Sakai Type</b> <b data-path-to-node="1" data-index-in-node="11">BL-100S-05</b></h3>
<p data-path-to-node="1">Includes battery &amp; charger. Pattern Test Cert No. TP8</p>
<p data-path-to-node="1"><img loading="lazy" decoding="async" class="aligncenter wp-image-56611" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-20_105823-removebg-preview.png" alt="" width="357" height="332" /></p>
<ul>
<li data-path-to-node="2,0,0">PL1 Efficiency</li>
<li data-path-to-node="2,1,0">Class B Leakage</li>
<li data-path-to-node="2,2,0">Assigned Protection Factor: 14</li>
</ul>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Applications:</b></p>
<ul>
<li data-path-to-node="4,0,0">General Dust</li>
<li data-path-to-node="4,1,0">Tunnel Construction</li>
</ul>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Replacement Filter: </b>Alpha Ring Filter BLA-6</p>
<h3 data-path-to-node="5"><b data-path-to-node="1" data-index-in-node="0">Sakai Type</b> <b data-path-to-node="1" data-index-in-node="11">BL-100SC-05</b></h3>
<p>Includes battery &amp; charger. Pattern Test Cert No. TP9<br />
<img loading="lazy" decoding="async" class=" wp-image-191653 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/2-1-300x207.png" alt="" width="338" height="233" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/2-1-300x207.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-1-1024x707.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-1-768x531.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-1.png 1375w" sizes="auto, (max-width: 338px) 100vw, 338px" /></p>
<ul>
<li data-path-to-node="2,0,0">PL1 Efficiency</li>
<li data-path-to-node="2,1,0">Class B Leakage</li>
<li data-path-to-node="2,2,0">Assigned Protection Factor: 14</li>
</ul>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Applications: </b>Welding (※)<br />
(※) For welding tasks requiring a protection factor under 14.</p>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">DANGER: </b>This is not a G-PAPR (Not for toxic gases).</p>
<p data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">Replacement Filter:</b></p>
<ul>
<li data-path-to-node="8,0,0">Alpha Ring Filter BLA-6C</li>
<li data-path-to-node="8,1,0">Includes inhalation port cover.</li>
</ul>
<h3><b data-path-to-node="1" data-index-in-node="0">Sakai Type</b> <b data-path-to-node="1" data-index-in-node="11">BL-100H-05</b></h3>
<p>Includes battery &amp; charger. Pattern Test Cert No. TP5<br />
<img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56613" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-20_110212-removebg-preview.png" alt="" width="222" height="250" /></p>
<ul>
<li data-path-to-node="2,0,0">PL3 Efficiency</li>
<li data-path-to-node="2,1,0">Class S Leakage</li>
<li data-path-to-node="2,2,0">Assigned Protection Factor: 300 (※2)</li>
</ul>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Applications:</b></p>
<ul>
<li data-path-to-node="4,0,0">Asbestos Removal</li>
<li data-path-to-node="4,1,0">Indium Handling</li>
<li data-path-to-node="4,2,0">RCF Handling</li>
<li data-path-to-node="4,3,0">Dioxin (Level 1)</li>
</ul>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Replacement Filter: </b>Alpha Ring Filter BRD-7</p>
<h3 data-path-to-node="5"><b data-path-to-node="1" data-index-in-node="0">Sakai Type</b> <b data-path-to-node="1" data-index-in-node="11">BL-100U-03</b></h3>
<p>Includes battery &amp; charger. Pattern Test Cert No. TP12<br />
<img loading="lazy" decoding="async" class=" wp-image-191659 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/1-2-300x204.png" alt="" width="343" height="233" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/1-2-300x204.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-2-1024x698.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-2-768x523.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-2.png 1296w" sizes="auto, (max-width: 343px) 100vw, 343px" /></p>
<ul>
<li data-path-to-node="2,0,0">PL3 Efficiency</li>
<li data-path-to-node="2,1,0">Class S Leakage</li>
<li data-path-to-node="2,2,0">Assigned Protection Factor: 300 (※2)</li>
</ul>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Applications: </b>Nanomaterial Handling</p>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">Replacement Filter: </b>Alpha Ring Filter BRD-8U</p>
<p data-path-to-node="1,0,0">※1 BL-100H and BL-100U do not share a common facepiece body.<br />
※2 Based on Simulated Workplace Protection Factor (SWPF) measurements conducted by our company, proving the protection factor exceeds 300.</p>
<h3>Performance Specifications</h3>
<table class="spec-table">
<thead>
<tr>
<th rowspan="2"><strong>Product Name</strong></th>
<th colspan="3"><strong>Classification</strong></th>
<th rowspan="2"><strong>Collection Efficiency</strong></th>
<th rowspan="2"><strong>Weight (incl. battery)</strong></th>
<th rowspan="2"><strong>Facepiece Weight</strong></th>
<th rowspan="2"><strong>Battery Specs</strong></th>
<th rowspan="2"><strong>Nominal Runtime*1</strong></th>
<th rowspan="2"><strong>Actual Runtime*2</strong></th>
<th rowspan="2"><strong>Fan Lifespan</strong></th>
</tr>
<tr>
<th><strong>Fan Type</strong></th>
<th><strong>Leakage Rate</strong></th>
<th><strong>Filter Grade</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td class="product">BL-711H</td>
<td rowspan="4">High Airflow</td>
<td rowspan="4">Class S (≤0.1%)</td>
<td rowspan="4">PL3</td>
<td>99.97% or more</td>
<td colspan="2">≤753g (Avg 723g)</td>
<td class="left" rowspan="4">Li-ion Rechargeable<br />
Voltage: 7.2V<br />
Capacity: 2000mAh<br />
Charging: ~3 hours*3<br />
Cycles: ~300 times*3</td>
<td rowspan="2">Approx. 6 hours</td>
<td rowspan="2">Approx. 6.5–10 hours</td>
<td rowspan="20">Approx. 2,000 hours*3</td>
</tr>
<tr>
<td class="product">BL-711U</td>
<td>99.99% or more</td>
<td colspan="2">≤753g (Avg 720g)</td>
</tr>
<tr>
<td class="product">BL-700HA</td>
<td>99.97% or more</td>
<td rowspan="2">≤774g</td>
<td rowspan="2">Avg 591g</td>
<td rowspan="2">Approx. 7.5 hours</td>
<td rowspan="2">Approx. 8–14.5 hours</td>
</tr>
<tr>
<td class="product">BL-700U</td>
<td>99.99% or more</td>
</tr>
<tr>
<td class="product">BL-7005/AL</td>
<td rowspan="3">Standard Airflow</td>
<td rowspan="3">Class A (≤1.0%)</td>
<td>PL2</td>
<td>99.0% or more</td>
<td colspan="2">≤298g (Avg 288g)</td>
<td rowspan="5">Li-ion Rechargeable<br />
Voltage: 3.7V<br />
Capacity: 1100mAh<br />
Charging: ~3 hours*3<br />
Cycles: ~300 times*3</td>
<td>Approx. 6.7 hours</td>
<td>Approx. 4–9 hours</td>
</tr>
<tr>
<td class="product">BL-1005/AL</td>
<td rowspan="3">PL1</td>
<td>95.0% or more</td>
<td colspan="2">≤278g (Avg 271g)</td>
<td rowspan="2">Approx. 8.5 hours</td>
<td rowspan="2">Approx. 3.5–11 hours</td>
</tr>
<tr>
<td class="product">BL-1005X/AL</td>
<td>95.0% or more</td>
<td colspan="2">≤285g (Avg 278g)</td>
</tr>
<tr>
<td class="product">BL-321S</td>
<td rowspan="13">High Airflow</td>
<td>Class B (≤5.0%)</td>
<td>95.0% or more</td>
<td colspan="2">≤252g (Avg 244g)</td>
<td>Approx. 3.5 hours</td>
<td>Approx. 5–9 hours</td>
</tr>
<tr>
<td class="product">BL-321H</td>
<td>Class S (≤0.1%)</td>
<td>PL3</td>
<td>99.97% or more</td>
<td colspan="2">≤265g (Avg 257g)</td>
<td>Approx. 3 hours</td>
<td>Approx. 3–6 hours</td>
</tr>
<tr>
<td class="product">BL-351S</td>
<td>Class B (≤5.0%)</td>
<td>PL1</td>
<td>95.0% or more</td>
<td colspan="2">Avg 315g</td>
<td rowspan="11">Li-ion Rechargeable<br />
Voltage: 7.2V<br />
Capacity: 2000mAh<br />
Charging: ~3 hours*3<br />
Cycles: ~300 times*3</td>
<td>Approx. 10 hours</td>
<td>Approx. 13–22 hours</td>
</tr>
<tr>
<td class="product">BL-351H</td>
<td rowspan="3">Class S (≤0.1%)</td>
<td rowspan="3">PL3</td>
<td>99.97% or more</td>
<td colspan="2" rowspan="2">Avg 328g</td>
<td rowspan="3">Approx. 9 hours</td>
<td rowspan="3">Approx. 8–17 hours</td>
</tr>
<tr>
<td class="product">BL-351U</td>
<td>99.99% or more</td>
</tr>
<tr>
<td class="product">BL-351HX</td>
<td>99.97% or more</td>
<td colspan="2">Avg 333g</td>
</tr>
<tr>
<td class="product">BL-200S</td>
<td>Class B (≤5.0%)</td>
<td>PL1</td>
<td>95.0% or more</td>
<td>≤395g</td>
<td>Avg 219g</td>
<td>Approx. 10.5 hours</td>
<td>Approx. 12–22 hours</td>
</tr>
<tr>
<td class="product">BL-200H</td>
<td rowspan="2">Class S (≤0.1%)</td>
<td rowspan="2">PL3</td>
<td>99.97% or more</td>
<td rowspan="2">≤409g</td>
<td rowspan="2">Avg 234g</td>
<td rowspan="2">Approx. 9.5 hours</td>
<td rowspan="2">Approx. 10–18 hours</td>
</tr>
<tr>
<td class="product">BL-200U</td>
<td>99.99% or more</td>
</tr>
<tr>
<td class="product">BL-100S</td>
<td rowspan="2">Class B (≤5.0%)</td>
<td rowspan="2">PL1</td>
<td rowspan="2">95.0% or more</td>
<td rowspan="2">≤383g</td>
<td rowspan="2">Avg 206g</td>
<td rowspan="2">Approx. 10 hours</td>
<td rowspan="2">Approx. 12–22 hours</td>
</tr>
<tr>
<td class="product">BL-100SC</td>
</tr>
<tr>
<td class="product">BL-100H</td>
<td rowspan="2">Class S (≤0.1%)</td>
<td rowspan="2">PL3</td>
<td>99.97% or more</td>
<td rowspan="2">≤397g</td>
<td rowspan="2">Avg 222g</td>
<td rowspan="2">Approx. 9 hours</td>
<td rowspan="2">Approx. 10–18 hours</td>
</tr>
<tr>
<td class="product">BL-100U</td>
<td>99.99% or more</td>
</tr>
</tbody>
</table>
<div class="note">
<div>*1 Time maintaining positive pressure under standard room conditions.</div>
<div>*2 Time maintaining positive pressure in dusty environments, based on actual worker respiratory data.</div>
<div>*3 May be shorter depending on usage conditions.</div>
</div>
<h3>Replacement Filters</h3>
<table>
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56599" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_155832-removebg-preview.png" alt="" width="201" height="127" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56598" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_155838-removebg-preview.png" alt="" width="200" height="128" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56597" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-15_155847-removebg-preview.png" alt="" width="177" height="129" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56600" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-155854.png" alt="" width="182" height="133" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56594" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-155741.png" alt="" width="174" height="126" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56595" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-155749.png" alt="" width="164" height="130" /></td>
<td width="64"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56596" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-155757.png" alt="" width="182" height="131" /></td>
</tr>
<tr>
<td height="19"><strong>Alpha Ring Filter BRD-82</strong> Screw-in type</td>
<td><strong>Alpha Ring Filter BRD-82U</strong> Screw-in type</td>
<td><strong>Alpha Ring Filter BLA-62</strong> Screw-in type</td>
<td><strong>Alpha Ring Filter BRD-7</strong></td>
<td><strong>Alpha Ring Filter BRD-8U</strong></td>
<td><strong>Alpha Ring Filter BLA-6</strong></td>
<td><strong>Alpha Ring Filter BLA-6C</strong></td>
</tr>
</tbody>
</table>
<p>● When performing work such as welding or grinding that generates sparks or spatter, be sure to use the dedicated inhalation port cover (sold separately) on the filter (except for BL-7005 and BL-1005 series). Note that BL-700HA/U, BL-200H/U, and BL-100H/U series should not be used in environments with sparks or spatter.</p>
<h3>Features:</h3>
<ul>
<li data-path-to-node="2,0,0"><b data-path-to-node="2,0,0" data-index-in-node="0">High Synchro:</b> Next-generation model improves airflow efficiency and tracks user breathing rhythm more accurately.</li>
<li data-path-to-node="2,1,0"><b data-path-to-node="2,1,0" data-index-in-node="0">Fit Checker:</b> Easily perform a fit test by simply pulling the lever.</li>
<li data-path-to-node="2,2,0"><b data-path-to-node="2,2,0" data-index-in-node="0">Under Chin:</b> Unique curved design enhances the airtight seal at the face contact area.</li>
<li data-path-to-node="2,3,0"><b data-path-to-node="2,3,0" data-index-in-node="0">Micron:</b> High-performance electrostatic filter material used in Micron filters.</li>
<li data-path-to-node="2,4,0"><b data-path-to-node="2,4,0" data-index-in-node="0">Speaker:</b> Integrated communication speaker ensures clear dialogue while wearing the mask.</li>
<li data-path-to-node="2,5,0"><b data-path-to-node="2,5,0" data-index-in-node="0">Special Hard Coating:</b> Improved scratch resistance compared to standard surface hardening treatments.</li>
<li data-path-to-node="2,6,0"><b data-path-to-node="2,6,0" data-index-in-node="0">Silicone:</b> Skin-friendly silicone material provides a soft and comfortable fit.</li>
<li data-path-to-node="2,7,0"><b data-path-to-node="2,7,0" data-index-in-node="0">Speaking Diaphragm:</b> Facilitates clear communication and instruction without mask removal.</li>
<li data-path-to-node="2,8,0"><b data-path-to-node="2,8,0" data-index-in-node="0">Internal Pressure Monitoring:</b> Flashing light alerts the user when positive pressure is lost inside the mask.</li>
<li data-path-to-node="2,9,0"><b data-path-to-node="2,9,0" data-index-in-node="0">HAWC Lip:</b> Full-face models use HAWC Lip structure for a high-seal &#8220;suction effect.&#8221;</li>
<li data-path-to-node="2,10,0"><b data-path-to-node="2,10,0" data-index-in-node="0">Hardened Eyepiece:</b> The visor surface is hardened to resist scratches.</li>
</ul>The post <a href="https://koueitrading.com/global/product/koken-bl-100-series-p-papr/">Koken BL-100 Series P-PAPR</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken BL-711HG-02 P-PAPR</title>
		<link>https://koueitrading.com/global/product/koken-bl-711hg-02-p-papr/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Wed, 04 Mar 2020 06:26:30 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=191647</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: BL-711HG-02 P-PAPR: Powered Air-Purifying Particulate Respirator PARTICULATE PAPR and GAS PAPR PAPR: Powered Air-Purifying Respirator. P-PAPR: Particulate PAPR (Used for dust/particles). G-PAPR: Gas PAPR (Used for toxic gases/vapors). Within the PAPR range, there are &#8220;Powered Air-Purifying Particulate Respirators (P-PAPR)&#8221; for dust hazards and &#8220;Powered Air-Purifying Gas Respirators (G-PAPR)&#8221; for toxic gas [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-bl-711hg-02-p-papr/">Koken BL-711HG-02 P-PAPR</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: BL-711HG-02</p>
<p>P-PAPR: Powered Air-Purifying Particulate Respirator</p>
<h2>PARTICULATE PAPR and GAS PAPR</h2>
<ul>
<li data-path-to-node="14,0,0">PAPR: Powered Air-Purifying Respirator.</li>
<li data-path-to-node="14,1,0">P-PAPR: Particulate PAPR (Used for dust/particles).</li>
<li data-path-to-node="14,2,0">G-PAPR: Gas PAPR (Used for toxic gases/vapors).</li>
</ul>
<p data-path-to-node="3">Within the PAPR range, there are &#8220;Powered Air-Purifying Particulate Respirators (P-PAPR)&#8221; for dust hazards and &#8220;Powered Air-Purifying Gas Respirators (G-PAPR)&#8221; for toxic gas hazards. It is essential to understand the properties, type, and concentration of the hazardous substances before selecting the appropriate mask.</p>
<p data-path-to-node="3">To prevent inhalation of DUST -&gt; Use a Powered Air-Purifying Particulate Respirator (P-PAPR)<br />
To prevent inhalation of TOXIC GAS -&gt; Use a Powered Air-Purifying Gas Respirator (G-PAPR)<br />
To prevent inhalation of MIXED DUST &amp; TOXIC GAS -&gt; Use a Powered Air-Purifying Gas Respirator (G-PAPR) with dust protection function</p>
<h3>Environments where PAPR CANNOT be used</h3>
<p data-path-to-node="9">PAPR must not be used if any of the following conditions apply. Please use respiratory protective equipment suitable for the environment, such as a supplied-air respirator or a self-contained breathing apparatus (SCBA).</p>
<ul>
<li data-path-to-node="10,0,0">Oxygen-deficient environments or those at risk of oxygen deficiency (Oxygen concentration below 18%).</li>
<li data-path-to-node="10,1,0">Cases where the type or concentration of the toxic gas is unknown.</li>
<li data-path-to-node="10,2,0">IDLH environments (Atmospheres Immediately Dangerous to Life or Health).</li>
<li data-path-to-node="10,2,0">Cases where the toxic gas concentration exceeds the permissible limit for the PAPR. ※</li>
<li data-path-to-node="10,3,0">Cases where no filter (canister) is available to remove the specific toxic gas in the environment.</li>
<li data-path-to-node="10,4,0">Cases where a mixture of gases with different properties exists.</li>
<li data-path-to-node="10,5,0">Cases where the environment deviates significantly from normal temperature, humidity, and atmospheric pressure.</li>
</ul>
<p data-path-to-node="11">(※ According to standards based on the Industrial Safety and Health Act, the application range of G-PAPR is 2% (3% for Ammonia))</p>
<h3>SELECTING THE APPROPRIATE PAPR BASED ON HAZARD CONCENTRATION</h3>
<p data-path-to-node="3">Determine the Required Protection Factor, then select a PAPR model with an Assigned Protection Factor higher than that value.</p>
<p data-path-to-node="4,0">Formula: How to calculate the Required Protection Factor<br />
<strong>Required Protection Factor = Ambient concentration of identified hazard / Permissible exposure limit of the hazard</strong></p>
<p>Assigned Protection Factor of P-PAPR</p>
<table>
<thead>
<tr>
<th colspan="2"><strong>Classification</strong></th>
<th colspan="4"><strong>Facepiece Type</strong></th>
</tr>
<tr>
<th><strong>Leakage Rate</strong></th>
<th><strong>Filter Efficiency</strong></th>
<th><strong>Half-face</strong></th>
<th><strong>Full-face</strong></th>
<th><strong>Hood Type</strong></th>
<th><strong>Face shield</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td rowspan="3">Class S</td>
<td>PL3/PS3</td>
<td>50/300</td>
<td>1000</td>
<td>25/1000</td>
<td>25/300</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>—</td>
<td>—</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td rowspan="3">Class A</td>
<td>PL3/PS3</td>
<td>—</td>
<td>—</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>33</td>
<td>90</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>14</td>
<td>19</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td rowspan="3">Class B</td>
<td>PL3/PS3</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>14</td>
<td>19</td>
<td>11</td>
<td>11</td>
</tr>
</tbody>
</table>
<p>Assigned Protection Factor of G-PAPR</p>
<table>
<thead>
<tr>
<th class="header-main" colspan="4"><strong>Facepiece Type</strong></th>
</tr>
<tr>
<th><strong>Half-face</strong></th>
<th><strong>Full-face</strong></th>
<th><strong>Hood Type</strong></th>
<th><strong>Face shield</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>50/300</td>
<td>1000</td>
<td>25/1000</td>
<td>25/300</td>
</tr>
</tbody>
</table>
<p>For &#8220;G-PAPR with dust protection function,&#8221; please refer to the Assigned Protection Factor of P-PAPR (Class S leakage rate) mentioned above for dust (and similar particulates).</p>
<h2>TASKS WHERE PAPR USE IS MANDATORY BY REGULATION OR DIRECTIVE</h2>
<p><strong>For tasks where PAPR use is mandatory by regulation or directive, please use a PAPR with the designated performance classification.</strong></p>
<h4><strong>1. Tunnel Construction Work</strong></h4>
<p><strong>Regulation:</strong> “Ordinance on Prevention of Pneumoconiosis”<br />
<strong>Scope:</strong> In tunnel construction, at locations involving “mechanical/powered excavation,” “mechanical loading or unloading of ore/rock,” and “shotcreting.”</p>
<p><strong>PAPR Requirements:</strong></p>
<ul>
<li>National test certified product (High airflow type).</li>
<li>Tight-fitting facepiece type where the battery can be removed for use during blasting operations.</li>
</ul>
<h4><strong>2. Asbestos Removal Work</strong></h4>
<p><strong>Regulation:</strong> “Ordinance on Prevention of Health Impairment due to Asbestos”<br />
<strong>Scope</strong>: In asbestos removal tasks, specifically those requiring “Class 1 Asbestos Removal Masks.”<br />
<b data-path-to-node="11,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified tight-fitting or hood types (High airflow, Class S, PL3 or PS3).</p>
<h4 data-path-to-node="12"><b data-path-to-node="12" data-index-in-node="0">3. Handling Nanomaterials</b></h4>
<p data-path-to-node="13,0,0"><b data-path-to-node="13,0,0" data-index-in-node="0">Directive:</b> “Regarding Preventive Measures for Exposure to Nanomaterials”<br />
<b data-path-to-node="13,1,0" data-index-in-node="0">Scope:</b> Manufacturing and handling of nanomaterials. (※)<br />
<b data-path-to-node="13,2,0" data-index-in-node="0">PAPR Requirements:</b></p>
<ul>
<li data-path-to-node="13,2,0">National test certified product (High airflow, PL3 or PS3).</li>
<li data-path-to-node="13,2,1,0,0">Shape limitations based on the projected exposure levels of workers.</li>
</ul>
<p data-path-to-node="13,2,1,1,0">(※) Depending on the work environment, respiratory protective equipment other than PAPR may be used.</p>
<h4 data-path-to-node="14"><b data-path-to-node="14" data-index-in-node="0">4. Handling Indium</b></h4>
<p data-path-to-node="15,0,0"><b data-path-to-node="15,0,0" data-index-in-node="0">Directive:</b> “Regarding Thorough Health Hazard Prevention Measures for Indium/Tin Oxide Handling”<br />
<b data-path-to-node="15,1,0" data-index-in-node="0">Scope:</b> Handling of Indium, Tin Oxide, etc. (※)<br />
<b data-path-to-node="15,2,0" data-index-in-node="0">PAPR Requirements:</b></p>
<ul>
<li data-path-to-node="15,2,0">National test certified product (High airflow, PL3 or PS3).</li>
<li data-path-to-node="15,2,1,0,0">Limitations on shape and leakage rate based on working environment measurement results.</li>
</ul>
<p data-path-to-node="15,2,1,1,0">(※) Depending on environmental results, respiratory protective equipment other than PAPR may be used.</p>
<h4 data-path-to-node="16"><b data-path-to-node="16" data-index-in-node="0">5. Handling Dioxins</b></h4>
<p><b data-path-to-node="17,0,0" data-index-in-node="0">Directive:</b> “Revision of Guidelines for Dioxin Exposure Prevention in Waste Incineration Facilities”<br />
<b data-path-to-node="17,1,0" data-index-in-node="0">Scope:</b> For dioxin-exposure risk tasks classified as “Level 1.” (※)<br />
<b data-path-to-node="17,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified product (High airflow, PL3 or PS3).</p>
<p>(※) RL3 or RS3 dust masks may be used, but PAPR with higher protective performance is recommended.</p>
<h4 data-path-to-node="18"><b data-path-to-node="18" data-index-in-node="0">6. Handling Refractory Ceramic Fibers (RCF)</b></h4>
<p><b data-path-to-node="19,0,0" data-index-in-node="0">Regulation:</b> “Ordinance on Prevention of Hazards due to Specified Chemical Substances”<br />
<b data-path-to-node="19,1,0" data-index-in-node="0">Scope:</b> Insulation or fireproofing work involving the application of RCF to furnaces or boilers; or repair, dismantling, and demolition of such furnaces/boilers.<br />
<b data-path-to-node="19,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified product (PL3 or PS3).</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong>PAPR Standards</strong></th>
<td width="64">Beyond JIS standards, Powered Air-Purifying Respirators must adhere to standards defined under the Industrial Safety and Health Act. These comprehensive standards ensure that products are manufactured under strict safety requirements.</td>
</tr>
</tbody>
</table>
<p>The following table is excerpted from the ‘Standards for Powered Air-Purifying Respirators’</p>
<h3>Types of Powered Air-Purifying Respirators</h3>
<table>
<tbody>
<tr>
<th colspan="2"><strong>Powered Air-Purifying Particulate Respirator (P-PAPR)</strong></th>
</tr>
<tr>
<th rowspan="2"><strong>Powered Air-Purifying Gas Respirator (G-PAPR)</strong></th>
<td>Type with dust protection function</td>
</tr>
<tr>
<td>Type without dust protection function</td>
</tr>
</tbody>
</table>
<p><strong>■ Classification by Shape</strong></p>
<table>
<tbody>
<tr>
<th rowspan="2"><strong>Tight-fitting Facepiece</strong><br />
<span class="sub-item">・Full-face</span><br />
<span class="sub-item">・Half-face</span></th>
<td>Isolation type (with hose)</td>
</tr>
<tr>
<td>Direct connection type</td>
</tr>
<tr>
<th rowspan="2"><strong>Loose-fitting Facepiece</strong><br />
<span class="sub-item">・Hood</span><br />
<span class="sub-item">・Face shield</span></th>
<td>Isolation type (with hose)</td>
</tr>
<tr>
<td>Direct connection type</td>
</tr>
</tbody>
</table>
<p><strong>■ Classification by Performance</strong></p>
<table>
<thead>
<tr>
<th><strong>Airflow Performance Classification</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>Standard airflow type</td>
</tr>
<tr>
<td>High airflow type</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th><strong>Leakage Rate Performance Classification (P-PAPR)</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>Class B</td>
</tr>
<tr>
<td>Class A</td>
</tr>
<tr>
<td>Class S</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th colspan="2"><strong>Filter Material Performance Classification<br />
(P-PAPR and G-PAPR with dust function)</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td width="50%">PS1</td>
<td width="50%">PL1</td>
</tr>
<tr>
<td>PS2</td>
<td>PL2</td>
</tr>
<tr>
<td>PS3</td>
<td>PL3</td>
</tr>
</tbody>
</table>
<h3>Performance Testing for Powered Air-Purifying Respirators</h3>
<h4><strong>■ Particle Collection Efficiency Test</strong></h4>
<p>(Applies only to P-PAPR and G-PAPR with dust protection)</p>
<table>
<tbody>
<tr>
<th class="header-bg col-label" rowspan="3"><strong>Test Particle</strong></th>
<th class="header-bg col-sub"><strong>Type</strong></th>
<td class="align-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="align-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="header-bg"><strong>Particle Size</strong></th>
<td colspan="2">0.06μm ~ 0.1μm</td>
<td colspan="2">0.15μm ~ 0.25μm</td>
</tr>
<tr>
<th class="header-bg"><strong>Concentration</strong></th>
<td colspan="2">50mg/m³ or less</td>
<td colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="header-bg" rowspan="2"><strong>Test Flow Rate</strong></th>
<th class="header-bg"><strong>Standard Flow</strong></th>
<td colspan="4">104 L/min</td>
</tr>
<tr>
<th class="header-bg"><strong>High Flow</strong></th>
<td colspan="4">138 L/min</td>
</tr>
<tr>
<th class="header-bg align-left" colspan="2" rowspan="4"><strong>Collection Efficiency<br />
(Continuous measurement; must meet values in the right column)</strong></th>
<td colspan="2">For NaCl, loaded up to 200mg</td>
<td colspan="2">For DOP, loaded up to 400mg</td>
</tr>
<tr>
<td class="col-val">PS1</td>
<td class="col-res">95.0% or more</td>
<td class="col-val">PL1</td>
<td class="col-res">95.0% or more</td>
</tr>
<tr>
<td>PS2</td>
<td>99.0% or more</td>
<td>PL2</td>
<td>99.0% or more</td>
</tr>
<tr>
<td>PS3</td>
<td>99.97% or more</td>
<td>PL3</td>
<td>99.97% or more</td>
</tr>
</tbody>
</table>
<h4><strong>■ Canister Testing </strong></h4>
<p>(Applies only to G-PAPR)</p>
<table>
<tbody>
<tr>
<th><strong>Airtightness</strong></th>
<td class="align-left" colspan="4">No air leakage at 1470 Pa pressure</td>
</tr>
<tr>
<th rowspan="5"><strong>Decontamination Capacity<br />
(Time until breakthrough at specified concentration must be ≥ the right column)</strong></th>
<th><strong>Type</strong></th>
<th><strong>Test Gas</strong></th>
<th><strong>Breakthrough Concentration</strong></th>
<th><strong>Duration</strong></th>
</tr>
<tr>
<td>Halogen gas</td>
<td>Chlorine (0.02%)</td>
<td>1 ppm</td>
<td>40 mins or more</td>
</tr>
<tr>
<td>Organic gas</td>
<td>Cyclohexane (0.03%)</td>
<td>5 ppm</td>
<td>50 mins or more</td>
</tr>
<tr>
<td>Ammonia</td>
<td>Ammonia (0.1%)</td>
<td>50 ppm</td>
<td>40 mins or more</td>
</tr>
<tr>
<td>SO₂ gas</td>
<td>Sulfur dioxide (0.03%)</td>
<td>5 ppm</td>
<td>35 mins or more</td>
</tr>
<tr>
<th><strong>Leakage Concentration</strong></th>
<td class="align-left" colspan="4">At maximum flow rate, time to reach breakthrough must be ≥ 3 minutes.</td>
</tr>
</tbody>
</table>
<h4><strong>■ Inward Leakage Rate Test</strong></h4>
<table>
<colgroup>
<col />
<col />
<col />
<col /></colgroup>
<tbody>
<tr>
<th rowspan="3"><strong>Test Particle</strong></th>
<th><strong>Type</strong></th>
<td colspan="4">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<th><strong>Particle Size</strong></th>
<td colspan="4">0.06μm ~ 0.2μm</td>
</tr>
<tr>
<th><strong>Concentration</strong></th>
<td colspan="4">18mg/m³ or less</td>
</tr>
<tr>
<th rowspan="4"><strong>Simulated Breathing</strong></th>
<th><strong>Type</strong></th>
<td colspan="2">Standard Flow</td>
<td colspan="2">High Flow</td>
</tr>
<tr>
<th><strong>Waveform</strong></th>
<td colspan="4">Sine wave</td>
</tr>
<tr>
<th><strong>Ventilation Volume</strong></th>
<td colspan="2">1.5 ± 0.075 L/stroke</td>
<td colspan="2">1.6 ± 0.08 L/stroke</td>
</tr>
<tr>
<th><strong>Frequency</strong></th>
<td colspan="2">20 times/min</td>
<td colspan="2">25 times/min</td>
</tr>
<tr>
<th colspan="2" rowspan="4"><strong>Leakage Rate<br />
(2-minute continuous measurement; max value must meet the right column)</strong></th>
<td rowspan="3">P-PAPR</td>
<td>Class B</td>
<td colspan="2">5.0% or less</td>
</tr>
<tr>
<td>Class A</td>
<td colspan="2">1.0% or less</td>
</tr>
<tr>
<td>Class S</td>
<td colspan="2">0.1% or less</td>
</tr>
<tr>
<td>G-PAPR</td>
<td colspan="3">0.1% or less</td>
</tr>
<tr>
<th colspan="2" rowspan="4"><strong>Headform Movement<br />
(Calculate leakage rate for each item)</strong></th>
<th colspan="3"><strong>Position and Range</strong></th>
<th><strong>Frequency</strong></th>
</tr>
<tr>
<td rowspan="2">Head</td>
<td colspan="2">Front/Back 30 degrees</td>
<td>17 times/min</td>
</tr>
<tr>
<td colspan="2">Left/Right rotation 50 degrees</td>
<td>11 times/min</td>
</tr>
<tr>
<td>Arms</td>
<td colspan="2">Raising 10 ~ 130 degrees</td>
<td>7 times/min</td>
</tr>
</tbody>
</table>
<h4><strong>■ Other Tests</strong></h4>
<table>
<tbody>
<tr>
<th><strong>Internal Pressure<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">Under simulated breathing identical to the leakage test:<br />
0 Pa &lt; Internal Mask Pressure &lt; 400 Pa</td>
</tr>
<tr>
<th rowspan="2"><strong>Minimum Required Flow<br />
(Loose-fit only)</strong></th>
<td class="align-center">Standard Flow</td>
<td class="align-center">104 L/min or more</td>
</tr>
<tr>
<td class="align-center">High Flow</td>
<td class="align-center">138 L/min or more</td>
</tr>
<tr>
<th><strong>Inhalation Resistance<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">160 Pa or less<br />
(40 L/min flow rate, fan OFF)</td>
</tr>
<tr>
<th><strong>Exhalation Resistance<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">80 Pa or less<br />
(40 L/min flow rate, fan OFF)</td>
</tr>
<tr>
<th><strong>Exhalation Valve Airtightness<br />
(Tight-fitting only)</strong></th>
<td class="content-cell" colspan="2">・Internal pressure must drop immediately when air is sucked.<br />
・Time for pressure to return to normal must be ≥ 15 seconds.</td>
</tr>
<tr>
<th><strong>CO2 Concentration Increase<br />
(Tight-fitting only)</strong></th>
<td class="content-cell" colspan="2">With fan OFF, headform breathes CO2 air. Difference between wearing and not wearing mask must be &lt; 2.0%.</td>
</tr>
<tr>
<th><strong>Noise Level</strong></th>
<td class="align-center" colspan="2">Noise at the headform ear area must be below 80 dB (both sides).</td>
</tr>
<tr>
<th rowspan="4"><strong>Flow Rate<br />
(G-PAPR only)</strong></th>
<td>Max set average flow</td>
<td class="content-cell">Average must be ≤ the decontamination test flow rate.</td>
</tr>
<tr>
<td>Maximum flow</td>
<td class="content-cell">Maximum must be ≤ the flow rate set by the manufacturer.</td>
</tr>
<tr>
<th><strong>Tight-fitting type</strong></th>
<th><strong>Loose-fitting type</strong></th>
</tr>
<tr>
<td class="content-cell">Measure resistance with fan OFF/ON at 20~170 L/min to calculate flow per minute.</td>
<td class="content-cell">With fan ON, draw air for 5 mins to maintain normal pressure in chamber, then measure flow.</td>
</tr>
</tbody>
</table>
<h2>PAPR USE IS ENCOURAGED IN THE 10TH COMPREHENSIVE DUST HAZARD COUNTERMEASURES</h2>
<p><strong>To reduce pneumoconiosis, dust prevention measures must be strengthened.</strong></p>
<p>The &#8220;10th Comprehensive Countermeasures for Preventing Dust Hazards&#8221; demands the correct use of effective respiratory protection against dust exposure across all industries. PAPR is highlighted as a &#8220;more effective preventive measure for health impairment,&#8221; and its adoption is highly encouraged.<br />
The use of PAPR is more effective in preventing health impairment compared to standard dust masks due to its higher protection factor and reduced physical strain on the wearer.<br />
(Partial excerpt from the 10th Comprehensive Countermeasures)</p>
<p>Furthermore, due to high performance, PAPR is mandatory for specific tasks, but its use is also recommended for tasks outside the mandatory categories.<br />
While PAPR is mandatory for specific operations under the Dust Rules, its high performance makes it desirable for other tasks; thus, guidance and inspections encourage businesses to adopt PAPR for their workers.<br />
(Partial excerpt from the 10th Comprehensive Countermeasures)</p>
<h2>KOKEN BL SERIES BREATH-RESPONSIVE PAPR</h2>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Achieving &#8220;High Safety&#8221; and &#8220;Comfortable Fit&#8221; as expected</b></p>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">THE EVOLUTION OF THE BL SERIES</b></p>
<p data-path-to-node="6">The BL Series continues to evolve into the PAPR model that helps perfect safety and health management in every field, aligning with occupational health trends and market expansion.</p>
<p data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">CORE DEVELOPMENT FOCUS</b></p>
<ul>
<li data-path-to-node="8,0,0"><b data-path-to-node="8,0,0" data-index-in-node="0">“Safety”:</b> Improving the protection capability as a respirator.</li>
<li data-path-to-node="8,1,0"><b data-path-to-node="8,1,0" data-index-in-node="0">“Flow Technology”:</b> Minimizing waste and improving efficiency.</li>
<li data-path-to-node="8,2,0"><b data-path-to-node="8,2,0" data-index-in-node="0">“Lightweight Design”:</b> Reducing the burden on the worker.</li>
</ul>
<h2>KOKEN FLOW TECHNOLOGY: New BSFS air flow highly synchronized with breathing</h2>
<h3>THE MECHANISM OF THE BSFS (BREATH SYNCHRONIZED) SYSTEM</h3>
<p data-path-to-node="5">The BL Series is equipped with the Breath Synchronized-Air Flow System (new BSFS), which delivers airflow that follows the breathing rhythm more closely than ever, becoming a &#8220;Highly Synchronized&#8221; model.<br />
BSFS ELIMINATES THE FEELING OF BREATHLESSNESS/STUFFINESS<br />
<img loading="lazy" decoding="async" class="size-medium wp-image-191639 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-300x177.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-300x177.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4.jpg 464w" alt="" width="300" height="177" /></p>
<p><b data-path-to-node="2" data-index-in-node="0">THE BSFS MECHANISM HAS EVOLVED INTO “HIGH SYNCHRONIZATION”</b></p>
<p data-path-to-node="3">Using a fan equipped with a breath detection sensor, the device supplies “the necessary and sufficient amount of air” corresponding to the user&#8217;s inhalation. Responsiveness to breathing has been improved, and the accuracy of synchronization with the respiratory rhythm has significantly increased.<br />
<img loading="lazy" decoding="async" class="size-medium wp-image-191638 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-300x286.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-300x286.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-768x733.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1.jpg 1024w" alt="" width="300" height="286" /></p>
<h3>COMFORT UP</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">SOLVING MASK DISCOMFORT WITH FLOW THAT FOLLOWS EVERY BREATH</b></p>
<ul>
<li data-path-to-node="4,0,0">Reduces the physical workload for laborers.</li>
<li data-path-to-node="4,1,0">Solves breathing difficulties and stuffiness in high-temperature workplaces.</li>
</ul>
<h3>SAFETY UP</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">PREVENTING INWARD LEAKAGE THROUGH HIGH PROTECTION AND CONSTANT POSITIVE PRESSURE</b></p>
<p data-path-to-node="4,0,0">Breath Synchronization: Protection is guaranteed by the blower linked to breathing.</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class=" wp-image-191633 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-300x227.jpg" sizes="auto, (max-width: 441px) 100vw, 441px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-300x227.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-768x581.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6.jpg 1024w" alt="" width="441" height="334" /></td>
<td width="64"><img loading="lazy" decoding="async" class=" wp-image-191636 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-300x218.png" sizes="auto, (max-width: 508px) 100vw, 508px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-300x218.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-1024x745.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-768x559.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185.png 1407w" alt="" width="508" height="369" /></td>
</tr>
<tr>
<td height="19">
<p data-path-to-node="3,0,0"><b data-path-to-node="3,0,0" data-index-in-node="0">DURING INHALATION:</b> Air inside the mask is normally sucked away, but supplemental airflow prevents negative pressure. (If a gap exists, air blows outward ※1)</p>
<p data-path-to-node="3,0,0">※1: Airflow varies based on facepiece fit.</p>
</td>
<td>
<p data-path-to-node="3,1,0"><b data-path-to-node="3,1,0" data-index-in-node="0">DURING EXHALATION:</b> Since pressure doesn&#8217;t drop, airflow is reduced. This conserves the &#8220;filter&#8221; and &#8220;battery.&#8221;</p>
<p data-path-to-node="3,1,0">※2: Flow doesn&#8217;t stop completely (maintains a small amount for safety).</p>
</td>
</tr>
</tbody>
</table>
<p><b data-path-to-node="2" data-index-in-node="0">PAPR AVOIDS HIGH LEAKAGE RISKS FROM DUST BUILDUP IN LOOSE MASKS</b></p>
<p data-path-to-node="3">FOR CONVENTIONAL DUST MASKS:</p>
<p data-path-to-node="4">As dust builds on the filter, inhalation resistance increases, raising the risk of inward leakage. As dust accumulates, even if the gap remains the same, the leakage rate can double. (See diagram below)</p>
<p><img loading="lazy" decoding="async" class=" wp-image-191632 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-300x195.jpg" sizes="auto, (max-width: 409px) 100vw, 409px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-300x195.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-768x500.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-180x118.jpg 180w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8.jpg 1024w" alt="" width="409" height="266" /></p>
<p><b data-path-to-node="7" data-index-in-node="0">Leakage Measurement Method:</b> A 2.5% gap is created intentionally; NaCl concentration is measured inside/outside the mask with a digital meter.</p>
<h3>ECONOMY UP (ECO)</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">ELIMINATING WASTE THROUGH AN ECO FLOW MECHANISM</b></p>
<p data-path-to-node="4,0,0">Limits “wasteful dust buildup” and reduces filter usage: Minimizes air loss to reduce clogging.<br />
Limits battery usage: Extends runtime by reducing power consumption during low-respiration phases.</p>
<p><b data-path-to-node="2" data-index-in-node="0">BATTERY RUNTIME COMPARISON: NEW VS OLD BSFS</b></p>
<p data-path-to-node="3"><img loading="lazy" decoding="async" class=" wp-image-191631 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/1-300x126.png" sizes="auto, (max-width: 445px) 100vw, 445px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/1-300x126.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-1024x429.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-768x322.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/1.png 1536w" alt="" width="445" height="187" /></p>
<p data-path-to-node="3"><strong>ECO FLOW CREATED BY HIGH SYNCHRONIZATION</strong></p>
<p data-path-to-node="3"><img loading="lazy" decoding="async" class=" wp-image-191630 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/2-300x175.png" sizes="auto, (max-width: 456px) 100vw, 456px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/2-300x175.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-1024x599.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-768x449.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/2.png 1536w" alt="" width="456" height="266" />Image of BSFS flow following actual respiratory waveforms with high precision.</p>
<h2 data-path-to-node="3">KOKEN LIGHTWEIGHT DESIGN: Reducing burden for long shifts</h2>
<p>The “BL Series” optimizes compact sizing and weight equivalent to conventional dust masks. It is highly rated in tunnel construction, asbestos handling, and arc welding.</p>
<p><b data-path-to-node="4" data-index-in-node="0">SEPARATE TYPE</b> Because a direct-mounted battery adds weight to the neck, the separate design reduces perceived weight. This ultra-lightweight design minimizes mask body thickness.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56541" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-122956.png" alt="" width="348" height="302" /></p>
<p><b data-path-to-node="5" data-index-in-node="0">BUILT-IN TYPE</b> Thanks to “High Synchro” BSFS reducing power draw, battery size has been shrunk. This results in a lightweight built-in battery design with minimal burden.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56542" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123026.png" alt="" width="212" height="269" /></p>
<h2>KOKEN SAFETY DESIGN: Internal pressure monitoring to maintain positive pressure</h2>
<p data-path-to-node="3">(Common for BL-321/BL-351/BL-351X/BL-711/BL-700/BL-200/BL-100 series)</p>
<p data-path-to-node="4">Modern worksites require PAPRs that “constantly monitor internal pressure and provide alerts.”<br />
PAPR is most protective under positive pressure; therefore, the moment positive pressure cannot be maintained is the filter replacement time. “Internal monitoring” notifies the user when pressure drops due to weak flow.<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56543" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123245.png" alt="" width="243" height="253" /></p>
<p data-path-to-node="7,0,0">■ Positive pressure inside the mask can be maintained through timely/appropriate filter replacement.<br />
■ Clarifies the standard for filter replacement – which is otherwise often vague or based on subjective estimation.<br />
■ Full airflow can be restored through proper battery charging.</p>
<p><b data-path-to-node="2" data-index-in-node="0">NOTIFICATION VIA AIRFLOW</b></p>
<p data-path-to-node="3">(For BL-321 / BL-351 / BL-351X / BL-711 series)</p>
<ul>
<li data-path-to-node="4,0,0">Pressure drop warning via “Continuous Airflow”: ➔ Replace the filter.</li>
<li data-path-to-node="4,1,0">Low battery warning via “Rhythmic Airflow”: ➔ Replace with a charged battery.</li>
</ul>
<p><b data-path-to-node="6" data-index-in-node="0">LED NOTIFICATION</b></p>
<p data-path-to-node="7">(For BL-700 / BL-200 / BL-100 series)</p>
<ul>
<li data-path-to-node="8,0,0">Pressure drop warning via “Flashing LED”: ➔ Replace the filter.</li>
<li data-path-to-node="8,1,0">Low battery warning via “Steady LED”: ➔ Replace with a charged battery.</li>
</ul>
<p><img loading="lazy" decoding="async" class=" wp-image-191629 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/3-300x65.png" sizes="auto, (max-width: 471px) 100vw, 471px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/3-300x65.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-1024x221.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-768x166.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/3.png 1536w" alt="" width="471" height="102" /></p>
<h2>Powered Air-Purifying Gas Respirator (G-PAPR)</h2>
<p>Scope of Use: Use only when the following conditions are met:</p>
<p data-path-to-node="3,0,0">■ Gas concentration must be lower than the permissible limit of each canister type.<br />
■ Required Protection Factor must be lower than the Assigned Protection Factor.</p>
<h3>BL-711 SERIES</h3>
<p>Full-face PAPR with high protective performance, also effective for eye protection.<br />
<strong>Features:</strong></p>
<ul>
<li data-path-to-node="4,0,0">High Synchro</li>
<li data-path-to-node="4,1,0">Silicone material</li>
<li data-path-to-node="4,2,0">HAWC Lip (High Adhesion seal)</li>
<li data-path-to-node="4,3,0">Speaker system</li>
<li data-path-to-node="4,4,0">Special Surface Hardening</li>
</ul>
<h3>Sakai Model BL-711HG-02</h3>
<p>Includes battery &amp; charger. Pattern Test Cert TP147<br />
Assigned Protection Factor: 1000<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-56617" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-20_112742-removebg-preview.png" alt="" width="283" height="272" /></p>
<p>*Canister sold separately</p>
<p data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">Options:</b></p>
<ul>
<li data-path-to-node="8,0,0"><b data-path-to-node="8,0,0" data-index-in-node="0">Glasses Clip Type A:</b> Clip for attaching prescription glasses inside the mask.</li>
<li data-path-to-node="8,1,0"><b data-path-to-node="8,1,0" data-index-in-node="0">Eyepiece Protector:</b> For H-VII and H-VII Type A series. Used to protect the eyepiece surface.</li>
</ul>
<p><strong>Shared Mask Body:</strong> Can be used as a P-PAPR (particulate mask) by installing a particulate filter.</p>
<p>■ Built-in battery type.<br />
■ Full-face eyepiece with a wide field of vision. Special coating improves scratch resistance.<br />
■ Low battery warning via &#8220;Alert airflow&#8221; function while wearing.<br />
■ &#8220;Silicone Mask Body&#8221; provides superior durability and high cleaning efficiency.<br />
■ Integrated &#8220;Speaker&#8221; for clear conversation.<br />
■ Designed shape for easy taping.</p>
<h3><strong>*Core Functions:</strong></h3>
<ul>
<li><strong>High Synchro:</strong> Next-gen model improving air supply efficiency and following user breathing rhythm more closely.</li>
<li><strong>Fit Checker:</strong> Perform a simple fit test by pulling up the lever.</li>
<li><strong>Under Chin:</strong> Enhances facial seal with a unique under-chin curve.</li>
<li><strong>Micron:</strong> Features the impressive electrostatic &#8220;Micron&#8221; filter.</li>
<li><strong>Speaker:</strong> Enables clear communication via a dedicated communication module.</li>
<li><strong>Special Surface Hardening:</strong> Special coating improves scratch resistance over standard methods.</li>
<li><strong>Silicone:</strong> Soft, skin-friendly medical-grade silicone mask body.</li>
<li><strong>Speaking Diaphragm:</strong> Allows conversation or instructions while wearing the mask.</li>
<li><strong>Internal Pressure Monitoring:</strong> LED flashes when positive pressure is not maintained.</li>
<li><strong>HAWC Lip:</strong> Full-face models use HAWC structure for a high seal suction effect.</li>
<li><strong>Surface Hardening:</strong> Hardened eyepiece surface resistant to scratching.</li>
</ul>The post <a href="https://koueitrading.com/global/product/koken-bl-711hg-02-p-papr/">Koken BL-711HG-02 P-PAPR</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Koken BL-351HGX-04 P-PAPR</title>
		<link>https://koueitrading.com/global/product/koken-bl-351hgx-04-p-papr/</link>
		
		<dc:creator><![CDATA[kvt part2]]></dc:creator>
		<pubDate>Wed, 04 Mar 2020 06:18:40 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=191641</guid>

					<description><![CDATA[<p>Manufacturer: KOKEN LTD. Model: BL-351HGX-04 P-PAPR: Powered Air-Purifying Particulate Respirator PARTICULATE PAPR and GAS PAPR PAPR: Powered Air-Purifying Respirator. P-PAPR: Particulate PAPR (Used for dust/particles). G-PAPR: Gas PAPR (Used for toxic gases/vapors). Within the PAPR range, there are &#8220;Powered Air-Purifying Particulate Respirators (P-PAPR)&#8221; for dust hazards and &#8220;Powered Air-Purifying Gas Respirators (G-PAPR)&#8221; for toxic gas [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/koken-bl-351hgx-04-p-papr/">Koken BL-351HGX-04 P-PAPR</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KOKEN LTD.<br />
Model: BL-351HGX-04</p>
<p>P-PAPR: Powered Air-Purifying Particulate Respirator</p>
<h2>PARTICULATE PAPR and GAS PAPR</h2>
<ul>
<li data-path-to-node="14,0,0">PAPR: Powered Air-Purifying Respirator.</li>
<li data-path-to-node="14,1,0">P-PAPR: Particulate PAPR (Used for dust/particles).</li>
<li data-path-to-node="14,2,0">G-PAPR: Gas PAPR (Used for toxic gases/vapors).</li>
</ul>
<p data-path-to-node="3">Within the PAPR range, there are &#8220;Powered Air-Purifying Particulate Respirators (P-PAPR)&#8221; for dust hazards and &#8220;Powered Air-Purifying Gas Respirators (G-PAPR)&#8221; for toxic gas hazards. It is essential to understand the properties, type, and concentration of the hazardous substances before selecting the appropriate mask.</p>
<p data-path-to-node="3">To prevent inhalation of DUST -&gt; Use a Powered Air-Purifying Particulate Respirator (P-PAPR)<br />
To prevent inhalation of TOXIC GAS -&gt; Use a Powered Air-Purifying Gas Respirator (G-PAPR)<br />
To prevent inhalation of MIXED DUST &amp; TOXIC GAS -&gt; Use a Powered Air-Purifying Gas Respirator (G-PAPR) with dust protection function</p>
<h3>Environments where PAPR CANNOT be used</h3>
<p data-path-to-node="9">PAPR must not be used if any of the following conditions apply. Please use respiratory protective equipment suitable for the environment, such as a supplied-air respirator or a self-contained breathing apparatus (SCBA).</p>
<ul>
<li style="list-style-type: none;">
<ul>
<li data-path-to-node="10,0,0">Oxygen-deficient environments or those at risk of oxygen deficiency (Oxygen concentration below 18%).</li>
<li data-path-to-node="10,1,0">IDLH environments (Atmospheres Immediately Dangerous to Life or Health).</li>
<li data-path-to-node="10,2,0">Cases where:
<ul>
<li data-path-to-node="10,2,0">The toxic gas concentration exceeds the permissible limit for the PAPR. ※</li>
<li data-path-to-node="10,3,0">No filter (canister) is available to remove the specific toxic gas in the environment.</li>
<li data-path-to-node="10,4,0">A mixture of gases with different properties exists.</li>
<li data-path-to-node="10,5,0">The environment deviates significantly from normal temperature, humidity, and atmospheric pressure.</li>
</ul>
</li>
</ul>
</li>
</ul>
<p data-path-to-node="11">(※ According to standards based on the Industrial Safety and Health Act, the application range of G-PAPR is 2% (3% for Ammonia))</p>
<h3>SELECTING THE APPROPRIATE PAPR BASED ON HAZARD CONCENTRATION</h3>
<p data-path-to-node="3">Determine the Required Protection Factor, then select a PAPR model with an Assigned Protection Factor higher than that value.</p>
<p data-path-to-node="4,0">Formula: How to calculate the Required Protection Factor<br />
<strong>Required Protection Factor = Ambient concentration of identified hazard / Permissible exposure limit of the hazard</strong></p>
<p>Assigned Protection Factor of P-PAPR</p>
<table>
<thead>
<tr>
<th colspan="2"><strong>Classification</strong></th>
<th colspan="4"><strong>Facepiece Type</strong></th>
</tr>
<tr>
<th><strong>Leakage Rate</strong></th>
<th><strong>Filter Efficiency</strong></th>
<th><strong>Half-face</strong></th>
<th><strong>Full-face</strong></th>
<th><strong>Hood Type</strong></th>
<th><strong>Face shield</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td rowspan="3">Class S</td>
<td>PL3/PS3</td>
<td>50/300</td>
<td>1000</td>
<td>25/1000</td>
<td>25/300</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>—</td>
<td>—</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td rowspan="3">Class A</td>
<td>PL3/PS3</td>
<td>—</td>
<td>—</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>33</td>
<td>90</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>14</td>
<td>19</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td rowspan="3">Class B</td>
<td>PL3/PS3</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td>PL2/PS2</td>
<td>—</td>
<td>—</td>
<td>11</td>
<td>11</td>
</tr>
<tr>
<td>PL1/PS1</td>
<td>14</td>
<td>19</td>
<td>11</td>
<td>11</td>
</tr>
</tbody>
</table>
<p>Assigned Protection Factor of G-PAPR</p>
<table>
<thead>
<tr>
<th class="header-main" colspan="4"><strong>Facepiece Type</strong></th>
</tr>
<tr>
<th><strong>Half-face</strong></th>
<th><strong>Full-face</strong></th>
<th><strong>Hood Type</strong></th>
<th><strong>Face shield</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>50/300</td>
<td>1000</td>
<td>25/1000</td>
<td>25/300</td>
</tr>
</tbody>
</table>
<p>For &#8220;G-PAPR with dust protection function,&#8221; please refer to the Assigned Protection Factor of P-PAPR (Class S leakage rate) mentioned above for dust (and similar particulates).</p>
<h2>TASKS WHERE PAPR USE IS MANDATORY BY REGULATION OR DIRECTIVE</h2>
<p><strong>For tasks where PAPR use is mandatory by regulation or directive, please use a PAPR with the designated performance classification.</strong></p>
<h4><strong>1. Tunnel Construction Work</strong></h4>
<p><strong>Regulation:</strong> “Ordinance on Prevention of Pneumoconiosis”<br />
<strong>Scope:</strong> In tunnel construction, at locations involving “mechanical/powered excavation,” “mechanical loading or unloading of ore/rock,” and “shotcreting.”</p>
<p><strong>PAPR Requirements:</strong></p>
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>National test certified product (High airflow type).</li>
<li>Tight-fitting facepiece type where the battery can be removed for use during blasting operations.</li>
</ul>
</li>
</ul>
</li>
</ul>
<h4><strong>2. Asbestos Removal Work</strong></h4>
<p><strong>Regulation:</strong> “Ordinance on Prevention of Health Impairment due to Asbestos”<br />
<strong>Scope</strong>: In asbestos removal tasks, specifically those requiring “Class 1 Asbestos Removal Masks.”<br />
<b data-path-to-node="11,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified tight-fitting or hood types (High airflow, Class S, PL3 or PS3).</p>
<h4 data-path-to-node="12"><b data-path-to-node="12" data-index-in-node="0">3. Handling Nanomaterials</b></h4>
<p data-path-to-node="13,0,0"><b data-path-to-node="13,0,0" data-index-in-node="0">Directive:</b> “Regarding Preventive Measures for Exposure to Nanomaterials”<br />
<b data-path-to-node="13,1,0" data-index-in-node="0">Scope:</b> Manufacturing and handling of nanomaterials. (※)<br />
<b data-path-to-node="13,2,0" data-index-in-node="0">PAPR Requirements:</b></p>
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li data-path-to-node="13,2,0">National test certified product (High airflow, PL3 or PS3).</li>
<li data-path-to-node="13,2,1,0,0">Shape limitations based on the projected exposure levels of workers.</li>
</ul>
</li>
</ul>
</li>
</ul>
<p data-path-to-node="13,2,1,1,0">(※) Depending on the work environment, respiratory protective equipment other than PAPR may be used.</p>
<h4 data-path-to-node="14"><b data-path-to-node="14" data-index-in-node="0">4. Handling Indium</b></h4>
<p data-path-to-node="15,0,0"><b data-path-to-node="15,0,0" data-index-in-node="0">Directive:</b> “Regarding Thorough Health Hazard Prevention Measures for Indium/Tin Oxide Handling”<br />
<b data-path-to-node="15,1,0" data-index-in-node="0">Scope:</b> Handling of Indium, Tin Oxide, etc. (※)<br />
<b data-path-to-node="15,2,0" data-index-in-node="0">PAPR Requirements:</b></p>
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li data-path-to-node="15,2,0">National test certified product (High airflow, PL3 or PS3).</li>
<li data-path-to-node="15,2,1,0,0">Limitations on shape and leakage rate based on working environment measurement results.</li>
</ul>
</li>
</ul>
</li>
</ul>
<p data-path-to-node="15,2,1,1,0">(※) Depending on environmental results, respiratory protective equipment other than PAPR may be used.</p>
<h4 data-path-to-node="16"><b data-path-to-node="16" data-index-in-node="0">5. Handling Dioxins</b></h4>
<p><b data-path-to-node="17,0,0" data-index-in-node="0">Directive:</b> “Revision of Guidelines for Dioxin Exposure Prevention in Waste Incineration Facilities”<br />
<b data-path-to-node="17,1,0" data-index-in-node="0">Scope:</b> For dioxin-exposure risk tasks classified as “Level 1.” (※)<br />
<b data-path-to-node="17,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified product (High airflow, PL3 or PS3).</p>
<p>(※) RL3 or RS3 dust masks may be used, but PAPR with higher protective performance is recommended.</p>
<h4 data-path-to-node="18"><b data-path-to-node="18" data-index-in-node="0">6. Handling Refractory Ceramic Fibers (RCF)</b></h4>
<p><b data-path-to-node="19,0,0" data-index-in-node="0">Regulation:</b> “Ordinance on Prevention of Hazards due to Specified Chemical Substances”<br />
<b data-path-to-node="19,1,0" data-index-in-node="0">Scope:</b> Insulation or fireproofing work involving the application of RCF to furnaces or boilers; or repair, dismantling, and demolition of such furnaces/boilers.<br />
<b data-path-to-node="19,2,0" data-index-in-node="0">PAPR Requirements:</b> National test certified product (PL3 or PS3).</p>
<table>
<tbody>
<tr>
<th width="64" height="19"><strong>PAPR Standards</strong></th>
<td width="64">Beyond JIS standards, Powered Air-Purifying Respirators must adhere to standards defined under the Industrial Safety and Health Act. These comprehensive standards ensure that products are manufactured under strict safety requirements.</td>
</tr>
</tbody>
</table>
<p>The following table is excerpted from the ‘Standards for Powered Air-Purifying Respirators’</p>
<h3>Types of Powered Air-Purifying Respirators</h3>
<table>
<tbody>
<tr>
<th colspan="2"><strong>Powered Air-Purifying Particulate Respirator (P-PAPR)</strong></th>
</tr>
<tr>
<th rowspan="2"><strong>Powered Air-Purifying Gas Respirator (G-PAPR)</strong></th>
<td>Type with dust protection function</td>
</tr>
<tr>
<td>Type without dust protection function</td>
</tr>
</tbody>
</table>
<p><strong>■ Classification by Shape</strong></p>
<table>
<tbody>
<tr>
<th rowspan="2"><strong>Tight-fitting Facepiece</strong><br />
<span class="sub-item">・Full-face</span><br />
<span class="sub-item">・Half-face</span></th>
<td>Isolation type (with hose)</td>
</tr>
<tr>
<td>Direct connection type</td>
</tr>
<tr>
<th rowspan="2"><strong>Loose-fitting Facepiece</strong><br />
<span class="sub-item">・Hood</span><br />
<span class="sub-item">・Face shield</span></th>
<td>Isolation type (with hose)</td>
</tr>
<tr>
<td>Direct connection type</td>
</tr>
</tbody>
</table>
<p><strong>■ Classification by Performance</strong></p>
<table>
<thead>
<tr>
<th><strong>Airflow Performance Classification</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>Standard airflow type</td>
</tr>
<tr>
<td>High airflow type</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th><strong>Leakage Rate Performance Classification (P-PAPR)</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td>Class B</td>
</tr>
<tr>
<td>Class A</td>
</tr>
<tr>
<td>Class S</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th colspan="2"><strong>Filter Material Performance Classification<br />
(P-PAPR and G-PAPR with dust function)</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td width="50%">PS1</td>
<td width="50%">PL1</td>
</tr>
<tr>
<td>PS2</td>
<td>PL2</td>
</tr>
<tr>
<td>PS3</td>
<td>PL3</td>
</tr>
</tbody>
</table>
<h3>Performance Testing for Powered Air-Purifying Respirators</h3>
<h4><strong>■ Particle Collection Efficiency Test</strong></h4>
<p>(Applies only to P-PAPR and G-PAPR with dust protection)</p>
<table>
<tbody>
<tr>
<th class="header-bg col-label" rowspan="3"><strong>Test Particle</strong></th>
<th class="header-bg col-sub"><strong>Type</strong></th>
<td class="align-center" colspan="2">NaCl (Sodium Chloride)</td>
<td class="align-center" colspan="2">DOP (Dioctyl Phthalate)</td>
</tr>
<tr>
<th class="header-bg"><strong>Particle Size</strong></th>
<td colspan="2">0.06μm ~ 0.1μm</td>
<td colspan="2">0.15μm ~ 0.25μm</td>
</tr>
<tr>
<th class="header-bg"><strong>Concentration</strong></th>
<td colspan="2">50mg/m³ or less</td>
<td colspan="2">100mg/m³ or less</td>
</tr>
<tr>
<th class="header-bg" rowspan="2"><strong>Test Flow Rate</strong></th>
<th class="header-bg"><strong>Standard Flow</strong></th>
<td colspan="4">104 L/min</td>
</tr>
<tr>
<th class="header-bg"><strong>High Flow</strong></th>
<td colspan="4">138 L/min</td>
</tr>
<tr>
<th class="header-bg align-left" colspan="2" rowspan="4"><strong>Collection Efficiency<br />
(Continuous measurement; must meet values in the right column)</strong></th>
<td colspan="2">For NaCl, loaded up to 200mg</td>
<td colspan="2">For DOP, loaded up to 400mg</td>
</tr>
<tr>
<td class="col-val">PS1</td>
<td class="col-res">95.0% or more</td>
<td class="col-val">PL1</td>
<td class="col-res">95.0% or more</td>
</tr>
<tr>
<td>PS2</td>
<td>99.0% or more</td>
<td>PL2</td>
<td>99.0% or more</td>
</tr>
<tr>
<td>PS3</td>
<td>99.97% or more</td>
<td>PL3</td>
<td>99.97% or more</td>
</tr>
</tbody>
</table>
<h4><strong>■ Canister Testing </strong></h4>
<p>(Applies only to G-PAPR)</p>
<table>
<tbody>
<tr>
<th><strong>Airtightness</strong></th>
<td class="align-left" colspan="4">No air leakage at 1470 Pa pressure</td>
</tr>
<tr>
<th rowspan="5"><strong>Decontamination Capacity<br />
(Time until breakthrough at specified concentration must be ≥ the right column)</strong></th>
<th><strong>Type</strong></th>
<th><strong>Test Gas</strong></th>
<th><strong>Breakthrough Concentration</strong></th>
<th><strong>Duration</strong></th>
</tr>
<tr>
<td>Halogen gas</td>
<td>Chlorine (0.02%)</td>
<td>1 ppm</td>
<td>40 mins or more</td>
</tr>
<tr>
<td>Organic gas</td>
<td>Cyclohexane (0.03%)</td>
<td>5 ppm</td>
<td>50 mins or more</td>
</tr>
<tr>
<td>Ammonia</td>
<td>Ammonia (0.1%)</td>
<td>50 ppm</td>
<td>40 mins or more</td>
</tr>
<tr>
<td>SO₂ gas</td>
<td>Sulfur dioxide (0.03%)</td>
<td>5 ppm</td>
<td>35 mins or more</td>
</tr>
<tr>
<th>Leakage Concentration</th>
<td class="align-left" colspan="4">At maximum flow rate, time to reach breakthrough must be ≥ 3 minutes.</td>
</tr>
</tbody>
</table>
<h4><strong>■ Inward Leakage Rate Test</strong></h4>
<table>
<colgroup>
<col />
<col />
<col />
<col /></colgroup>
<tbody>
<tr>
<th rowspan="3"><strong>Test Particle</strong></th>
<th><strong>Type</strong></th>
<td colspan="4">NaCl (Sodium Chloride)</td>
</tr>
<tr>
<th><strong>Particle Size</strong></th>
<td colspan="4">0.06μm ~ 0.2μm</td>
</tr>
<tr>
<th><strong>Concentration</strong></th>
<td colspan="4">18mg/m³ or less</td>
</tr>
<tr>
<th rowspan="4"><strong>Simulated Breathing</strong></th>
<th><strong>Type</strong></th>
<td colspan="2">Standard Flow</td>
<td colspan="2">High Flow</td>
</tr>
<tr>
<th><strong>Waveform</strong></th>
<td colspan="4">Sine wave</td>
</tr>
<tr>
<th><strong>Ventilation Volume</strong></th>
<td colspan="2">1.5 ± 0.075 L/stroke</td>
<td colspan="2">1.6 ± 0.08 L/stroke</td>
</tr>
<tr>
<th><strong>Frequency</strong></th>
<td colspan="2">20 times/min</td>
<td colspan="2">25 times/min</td>
</tr>
<tr>
<th colspan="2" rowspan="4"><strong>Leakage Rate<br />
(2-minute continuous measurement; max value must meet the right column)</strong></th>
<td rowspan="3">P-PAPR</td>
<td>Class B</td>
<td colspan="2">5.0% or less</td>
</tr>
<tr>
<td>Class A</td>
<td colspan="2">1.0% or less</td>
</tr>
<tr>
<td>Class S</td>
<td colspan="2">0.1% or less</td>
</tr>
<tr>
<td>G-PAPR</td>
<td colspan="3">0.1% or less</td>
</tr>
<tr>
<th colspan="2" rowspan="4"><strong>Headform Movement<br />
(Calculate leakage rate for each item)</strong></th>
<th colspan="3"><strong>Position and Range</strong></th>
<th><strong>Frequency</strong></th>
</tr>
<tr>
<td rowspan="2">Head</td>
<td colspan="2">Front/Back 30 degrees</td>
<td>17 times/min</td>
</tr>
<tr>
<td colspan="2">Left/Right rotation 50 degrees</td>
<td>11 times/min</td>
</tr>
<tr>
<td>Arms</td>
<td colspan="2">Raising 10 ~ 130 degrees</td>
<td>7 times/min</td>
</tr>
</tbody>
</table>
<h4><strong>■ Other Tests</strong></h4>
<table>
<tbody>
<tr>
<th><strong>Internal Pressure<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">Under simulated breathing identical to the leakage test:<br />
0 Pa &lt; Internal Mask Pressure &lt; 400 Pa</td>
</tr>
<tr>
<th rowspan="2"><strong>Minimum Required Flow<br />
(Loose-fit only)</strong></th>
<td class="align-center">Standard Flow</td>
<td class="align-center">104 L/min or more</td>
</tr>
<tr>
<td class="align-center">High Flow</td>
<td class="align-center">138 L/min or more</td>
</tr>
<tr>
<th><strong>Inhalation Resistance<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">160 Pa or less<br />
(40 L/min flow rate, fan OFF)</td>
</tr>
<tr>
<th><strong>Exhalation Resistance<br />
(Tight-fitting only)</strong></th>
<td class="align-center" colspan="2">80 Pa or less<br />
(40 L/min flow rate, fan OFF)</td>
</tr>
<tr>
<th><strong>Exhalation Valve Airtightness<br />
(Tight-fitting only)</strong></th>
<td class="content-cell" colspan="2">・Internal pressure must drop immediately when air is sucked.<br />
・Time for pressure to return to normal must be ≥ 15 seconds.</td>
</tr>
<tr>
<th><strong>CO2 Concentration Increase<br />
(Tight-fitting only)</strong></th>
<td class="content-cell" colspan="2">With fan OFF, headform breathes CO2 air. Difference between wearing and not wearing mask must be &lt; 2.0%.</td>
</tr>
<tr>
<th><strong>Noise Level</strong></th>
<td class="align-center" colspan="2">Noise at the headform ear area must be below 80 dB (both sides).</td>
</tr>
<tr>
<th rowspan="4"><strong>Flow Rate<br />
(G-PAPR only)</strong></th>
<td>Max set average flow</td>
<td class="content-cell">Average must be ≤ the decontamination test flow rate.</td>
</tr>
<tr>
<td>Maximum flow</td>
<td class="content-cell">Maximum must be ≤ the flow rate set by the manufacturer.</td>
</tr>
<tr>
<th><strong>Tight-fitting type</strong></th>
<th><strong>Loose-fitting type</strong></th>
</tr>
<tr>
<td class="content-cell">Measure resistance with fan OFF/ON at 20~170 L/min to calculate flow per minute.</td>
<td class="content-cell">With fan ON, draw air for 5 mins to maintain normal pressure in chamber, then measure flow.</td>
</tr>
</tbody>
</table>
<h2>PAPR USE IS ENCOURAGED IN THE 10TH COMPREHENSIVE DUST HAZARD COUNTERMEASURES</h2>
<p><strong>To reduce pneumoconiosis, dust prevention measures must be strengthened.</strong></p>
<p>The &#8220;10th Comprehensive Countermeasures for Preventing Dust Hazards&#8221; demands the correct use of effective respiratory protection against dust exposure across all industries. PAPR is highlighted as a &#8220;more effective preventive measure for health impairment,&#8221; and its adoption is highly encouraged.<br />
The use of PAPR is more effective in preventing health impairment compared to standard dust masks due to its higher protection factor and reduced physical strain on the wearer.<br />
(Partial excerpt from the 10th Comprehensive Countermeasures)</p>
<p>Furthermore, due to high performance, PAPR is mandatory for specific tasks, but its use is also recommended for tasks outside the mandatory categories.<br />
While PAPR is mandatory for specific operations under the Dust Rules, its high performance makes it desirable for other tasks; thus, guidance and inspections encourage businesses to adopt PAPR for their workers.<br />
(Partial excerpt from the 10th Comprehensive Countermeasures)</p>
<h2>KOKEN BL SERIES BREATH-RESPONSIVE PAPR</h2>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Achieving &#8220;High Safety&#8221; and &#8220;Comfortable Fit&#8221; as expected</b></p>
<p data-path-to-node="5"><b data-path-to-node="5" data-index-in-node="0">THE EVOLUTION OF THE BL SERIES</b></p>
<p data-path-to-node="6">The BL Series continues to evolve into the PAPR model that helps perfect safety and health management in every field, aligning with occupational health trends and market expansion.</p>
<p data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">CORE DEVELOPMENT FOCUS</b></p>
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li data-path-to-node="8,0,0"><b data-path-to-node="8,0,0" data-index-in-node="0">“Safety”:</b> Improving the protection capability as a respirator.</li>
<li data-path-to-node="8,1,0"><b data-path-to-node="8,1,0" data-index-in-node="0">“Flow Technology”:</b> Minimizing waste and improving efficiency.</li>
<li data-path-to-node="8,2,0"><b data-path-to-node="8,2,0" data-index-in-node="0">“Lightweight Design”:</b> Reducing the burden on the worker.</li>
</ul>
</li>
</ul>
</li>
</ul>
<h2>KOKEN FLOW TECHNOLOGY: New BSFS air flow highly synchronized with breathing</h2>
<h3>THE MECHANISM OF THE BSFS (BREATH SYNCHRONIZED) SYSTEM</h3>
<p data-path-to-node="5">The BL Series is equipped with the Breath Synchronized-Air Flow System (new BSFS), which delivers airflow that follows the breathing rhythm more closely than ever, becoming a &#8220;Highly Synchronized&#8221; model.<br />
BSFS ELIMINATES THE FEELING OF BREATHLESSNESS/STUFFINESS<br />
<img loading="lazy" decoding="async" class="size-medium wp-image-191639 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-300x177.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4-300x177.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-4.jpg 464w" alt="" width="300" height="177" /></p>
<p><b data-path-to-node="2" data-index-in-node="0">THE BSFS MECHANISM HAS EVOLVED INTO “HIGH SYNCHRONIZATION”</b></p>
<p data-path-to-node="3">Using a fan equipped with a breath detection sensor, the device supplies “the necessary and sufficient amount of air” corresponding to the user&#8217;s inhalation. Responsiveness to breathing has been improved, and the accuracy of synchronization with the respiratory rhythm has significantly increased.</p>
<p data-path-to-node="5"><img loading="lazy" decoding="async" class="size-medium wp-image-191638 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-300x286.jpg" sizes="auto, (max-width: 300px) 100vw, 300px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-300x286.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1-768x733.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-5-1.jpg 1024w" alt="" width="300" height="286" /></p>
<h3>COMFORT UP</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">SOLVING MASK DISCOMFORT WITH FLOW THAT FOLLOWS EVERY BREATH</b></p>
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li data-path-to-node="4,0,0">Reduces the physical workload for laborers.</li>
<li data-path-to-node="4,1,0">Solves breathing difficulties and stuffiness in high-temperature workplaces.</li>
</ul>
</li>
</ul>
</li>
</ul>
<h3>SAFETY UP</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">PREVENTING INWARD LEAKAGE THROUGH HIGH PROTECTION AND CONSTANT POSITIVE PRESSURE</b></p>
<p data-path-to-node="4,0,0">Breath Synchronization: Protection is guaranteed by the blower linked to breathing.</p>
<table>
<tbody>
<tr>
<td width="64" height="19"><img loading="lazy" decoding="async" class=" wp-image-191633 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-300x227.jpg" sizes="auto, (max-width: 441px) 100vw, 441px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-300x227.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6-768x581.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-6.jpg 1024w" alt="" width="441" height="334" /></td>
<td width="64"><img loading="lazy" decoding="async" class=" wp-image-191636 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-300x218.png" sizes="auto, (max-width: 508px) 100vw, 508px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-300x218.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-1024x745.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185-768x559.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/a07e1e7f-f925-4b17-9b93-e7031c150185.png 1407w" alt="" width="508" height="369" /></td>
</tr>
<tr>
<td height="19">
<p data-path-to-node="3,0,0"><b data-path-to-node="3,0,0" data-index-in-node="0">DURING INHALATION:</b> Air inside the mask is normally sucked away, but supplemental airflow prevents negative pressure. (If a gap exists, air blows outward ※1)</p>
<p data-path-to-node="3,0,0">※1: Airflow varies based on facepiece fit.</p>
</td>
<td>
<p data-path-to-node="3,1,0"><b data-path-to-node="3,1,0" data-index-in-node="0">DURING EXHALATION:</b> Since pressure doesn&#8217;t drop, airflow is reduced. This conserves the &#8220;filter&#8221; and &#8220;battery.&#8221;</p>
<p data-path-to-node="3,1,0">※2: Flow doesn&#8217;t stop completely (maintains a small amount for safety).</p>
</td>
</tr>
</tbody>
</table>
<p><b data-path-to-node="2" data-index-in-node="0">PAPR AVOIDS HIGH LEAKAGE RISKS FROM DUST BUILDUP IN LOOSE MASKS</b></p>
<p data-path-to-node="3">FOR CONVENTIONAL DUST MASKS:</p>
<p data-path-to-node="4">As dust builds on the filter, inhalation resistance increases, raising the risk of inward leakage. As dust accumulates, even if the gap remains the same, the leakage rate can double. (See diagram below)</p>
<p><img loading="lazy" decoding="async" class=" wp-image-191632 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-300x195.jpg" sizes="auto, (max-width: 409px) 100vw, 409px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-300x195.jpg 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-768x500.jpg 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8-180x118.jpg 180w, https://koueitrading.com/global/wp-content/uploads/2026/03/unnamed-8.jpg 1024w" alt="" width="409" height="266" /></p>
<p><b data-path-to-node="7" data-index-in-node="0">Leakage Measurement Method:</b> A 2.5% gap is created intentionally; NaCl concentration is measured inside/outside the mask with a digital meter.</p>
<h3>ECONOMY UP (ECO)</h3>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">ELIMINATING WASTE THROUGH AN ECO FLOW MECHANISM</b></p>
<p data-path-to-node="4,0,0">Limits “wasteful dust buildup” and reduces filter usage: Minimizes air loss to reduce clogging.<br />
Limits battery usage: Extends runtime by reducing power consumption during low-respiration phases.</p>
<p><b data-path-to-node="2" data-index-in-node="0">BATTERY RUNTIME COMPARISON: NEW VS OLD BSFS</b></p>
<p data-path-to-node="3"><img loading="lazy" decoding="async" class=" wp-image-191631 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/1-300x126.png" sizes="auto, (max-width: 445px) 100vw, 445px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/1-300x126.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-1024x429.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/1-768x322.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/1.png 1536w" alt="" width="445" height="187" /></p>
<p data-path-to-node="3"><strong>ECO FLOW CREATED BY HIGH SYNCHRONIZATION</strong></p>
<p data-path-to-node="3"><img loading="lazy" decoding="async" class=" wp-image-191630 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/2-300x175.png" sizes="auto, (max-width: 456px) 100vw, 456px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/2-300x175.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-1024x599.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/2-768x449.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/2.png 1536w" alt="" width="456" height="266" />Image of BSFS flow following actual respiratory waveforms with high precision.</p>
<h2 data-path-to-node="3">KOKEN LIGHTWEIGHT DESIGN: Reducing burden for long shifts</h2>
<p>The “BL Series” optimizes compact sizing and weight equivalent to conventional dust masks. It is highly rated in tunnel construction, asbestos handling, and arc welding.</p>
<p><b data-path-to-node="4" data-index-in-node="0">SEPARATE TYPE</b> Because a direct-mounted battery adds weight to the neck, the separate design reduces perceived weight. This ultra-lightweight design minimizes mask body thickness.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56541" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-122956.png" alt="" width="348" height="302" /></p>
<p><b data-path-to-node="5" data-index-in-node="0">BUILT-IN TYPE</b> Thanks to “High Synchro” BSFS reducing power draw, battery size has been shrunk. This results in a lightweight built-in battery design with minimal burden.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-56542" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123026.png" alt="" width="212" height="269" /></p>
<h2>KOKEN SAFETY DESIGN: Internal pressure monitoring to maintain positive pressure</h2>
<p data-path-to-node="3">(Common for BL-321/BL-351/BL-351X/BL-711/BL-700/BL-200/BL-100 series)</p>
<p data-path-to-node="4">Modern worksites require PAPRs that “constantly monitor internal pressure and provide alerts.”<br />
PAPR is most protective under positive pressure; therefore, the moment positive pressure cannot be maintained is the filter replacement time. “Internal monitoring” notifies the user when pressure drops due to weak flow.</p>
<p data-path-to-node="7,0,0">■ Timely filter replacement ensures constant positive pressure.<br />
■ Clarifies replacement standards previously based on intuition.<br />
■ Battery charging restores full flow performance.</p>
<p data-path-to-node="7,0,0"><img loading="lazy" decoding="async" class="aligncenter wp-image-56543" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot-2026-01-15-123245.png" alt="" width="243" height="253" /></p>
<p><b data-path-to-node="2" data-index-in-node="0">AIRFLOW NOTIFICATION</b></p>
<p data-path-to-node="3">(For BL-321 / BL-351 / BL-351X / BL-711 series)</p>
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li data-path-to-node="4,0,0">Pressure drop warning via “Continuous Airflow”: ➔ Replace the filter.</li>
<li data-path-to-node="4,1,0">Low battery warning via “Rhythmic Airflow”: ➔ Replace with a charged battery.</li>
</ul>
</li>
</ul>
</li>
</ul>
<p><b data-path-to-node="6" data-index-in-node="0">LED NOTIFICATION</b></p>
<p data-path-to-node="7">(For BL-700 / BL-200 / BL-100 series)</p>
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li data-path-to-node="8,0,0">Pressure drop warning via “Flashing LED”: ➔ Replace the filter.</li>
<li data-path-to-node="8,1,0">Low battery warning via “Steady LED”: ➔ Replace with a charged battery.</li>
</ul>
</li>
</ul>
</li>
</ul>
<p><img loading="lazy" decoding="async" class=" wp-image-191629 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2026/03/3-300x65.png" sizes="auto, (max-width: 471px) 100vw, 471px" srcset="https://koueitrading.com/global/wp-content/uploads/2026/03/3-300x65.png 300w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-1024x221.png 1024w, https://koueitrading.com/global/wp-content/uploads/2026/03/3-768x166.png 768w, https://koueitrading.com/global/wp-content/uploads/2026/03/3.png 1536w" alt="" width="471" height="102" /></p>
<h2>Powered Air-Purifying Gas Respirator (G-PAPR)</h2>
<p data-path-to-node="2">Scope of Use: Use only when the following conditions are met:</p>
<p data-path-to-node="3,0,0">■ Gas concentration must be lower than the permissible limit of each canister type.<br />
■ Required Protection Factor must be lower than the Assigned Protection Factor.</p>
<h3>BL-351X SERIES</h3>
<p data-path-to-node="2">Half-face PAPR with integrated internal battery</p>
<p data-path-to-node="3"><b data-path-to-node="3" data-index-in-node="0">Features:</b></p>
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li data-path-to-node="4,0,0">High Synchro</li>
<li data-path-to-node="4,1,0">Under Chin design</li>
<li data-path-to-node="4,2,0">Silicone material</li>
<li data-path-to-node="4,3,0">Speaking diaphragm</li>
</ul>
</li>
</ul>
</li>
</ul>
<h3><b data-path-to-node="1" data-index-in-node="0">Sakai Type</b> <b data-path-to-node="1" data-index-in-node="11">BL-351HGX-04</b></h3>
<p>Includes battery &amp; charger. Pattern Test Cert TP150<br />
Assigned Protection Factor: 300 (※)</p>
<p>(※) SWPF measurements conducted by our company prove the assigned factor exceeds 300.</p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-56622" src="https://koueitrading.com/vn/wp-content/uploads/2026/01/Screenshot_2026-01-20_115340-removebg-preview.png" alt="" width="295" height="327" /></p>
<p>*Canister sold separately</p>
<p data-path-to-node="3,0,0"><b data-path-to-node="3,0,0" data-index-in-node="0">Shared Mask Body: </b>Can be used as a P-PAPR (particulate mask) by installing a particulate filter.</p>
<p>■ High water resistance &#8220;IP55&#8221;<br />
■ Integrated &#8220;Speaking Diaphragm&#8221; for clear conversation<br />
■ &#8220;Auto ON/OFF&#8221; function: Fan starts automatically upon breathing<br />
■ Low battery warning via &#8220;Airflow Notification&#8221;</p>
<p><strong>Performance</strong></p>
<table>
<thead>
<tr>
<th><strong>Model</strong></th>
<th><strong>Fan Performance</strong></th>
<th><strong>Leakage Rate</strong></th>
<th><strong>Weight (incl. battery)</strong></th>
<th><strong>Battery Specs</strong></th>
<th><strong>Runtime <sup>*1</sup></strong></th>
<th><strong>Fan Durability</strong></th>
</tr>
</thead>
<tbody>
<tr>
<td class="product-name">BL-711HG</td>
<td rowspan="2">High flow rate</td>
<td rowspan="2">&lt; 0.1%</td>
<td>771g</td>
<td rowspan="2">Li-ion Rechargeable<br />
7.2V / 2000mAh<br />
Charge: ~3 hrs <sup>*3</sup><br />
Cycles: ~300 <sup>*3</sup></td>
<td>~5 hours <sup>*2</sup></td>
<td rowspan="2">~2,000 hours <sup>*3</sup></td>
</tr>
<tr>
<td class="product-name">BL-351HGX</td>
<td>384g</td>
<td>~6 hours <sup>*2</sup></td>
</tr>
</tbody>
</table>
<p>*1 Time maintaining positive pressure under standard breathing conditions per Industrial Safety and Health Law.<br />
*2 Time when BRDG-82 canister is installed.<br />
*3 Varies depending on actual usage conditions.</p>
<h3><strong>*Key Features:</strong></h3>
<ul>
<li style="list-style-type: none;">
<ul>
<li><strong>High Synchro:</strong> Next-gen model improving air supply efficiency and following user breathing rhythm more closely.</li>
<li><strong>Fit Checker:</strong> Perform a simple fit test by pulling up the lever.</li>
<li><strong>Under Chin:</strong> Enhances facial seal with a unique under-chin curve.</li>
<li><strong>Micron:</strong> Features the impressive electrostatic &#8220;Micron&#8221; filter.</li>
<li><strong>Speaker:</strong> Enables clear communication via a dedicated communication module.</li>
<li><strong>Special Surface Hardening:</strong> Special coating improves scratch resistance over standard methods.</li>
<li><strong>Silicone:</strong> Soft, skin-friendly medical-grade silicone mask body.</li>
<li><strong>Speaking Diaphragm:</strong> Allows conversation or instructions while wearing the mask.</li>
<li><strong>Internal Pressure Monitoring:</strong> LED flashes when positive pressure is not maintained.</li>
<li><strong>HAWC Lip:</strong> Full-face models use HAWC structure for a high seal suction effect.</li>
<li><strong>Surface Hardening:</strong> Hardened eyepiece surface resistant to scratching.</li>
</ul>
</li>
</ul>The post <a href="https://koueitrading.com/global/product/koken-bl-351hgx-04-p-papr/">Koken BL-351HGX-04 P-PAPR</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
