<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Kyowa Electronic Instruments Co., Ltd. | Kouei Japan Trading | Get Quotation</title>
	<atom:link href="https://koueitrading.com/global/product-cat/kyowa-electronic-instruments-co-ltd/feed/" rel="self" type="application/rss+xml" />
	<link>https://koueitrading.com/global</link>
	<description>Purchase tools and equipments made in Japan</description>
	<lastBuildDate>Tue, 14 Jan 2025 02:58:32 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.5</generator>

<image>
	<url>https://koueitrading.com/global/wp-content/uploads/2018/01/cropped-KoueiVietnam-logo-32x32.png</url>
	<title>Kyowa Electronic Instruments Co., Ltd. | Kouei Japan Trading | Get Quotation</title>
	<link>https://koueitrading.com/global</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Kyowa CVM-41A Strain/Voltage/Acceleration Measurement Card EDX Series Conditioner Card</title>
		<link>https://koueitrading.com/global/product/kyowa-cvm-41a-strain-voltage-acceleration-measurement-card-edx-series-conditioner-card/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Mon, 17 Aug 2020 17:23:37 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=82769</guid>

					<description><![CDATA[<p>Manufacturer: Kyowa Electronic Instruments Co., Ltd. Model: CVM-41A Strain/Voltage/Acceleration Conditioner card for EDX-200A and EDX-5000A Feature of CVM-41A Strain/Voltage/Acceleration You can select according to the application. In addition to strain, voltage, acceleration, and temperature measurements, CAN data is also supported. Furthermore, noise-resistant isolation amplifier cards are available. Additionally, dynamic strain measurement cards are offered, enhancing [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/kyowa-cvm-41a-strain-voltage-acceleration-measurement-card-edx-series-conditioner-card/">Kyowa CVM-41A Strain/Voltage/Acceleration Measurement Card EDX Series Conditioner Card</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: Kyowa Electronic Instruments Co., Ltd.<br />
Model: CVM-41A Strain/Voltage/Acceleration</p>
<p>Conditioner card for EDX-200A and EDX-5000A<br />
<img fetchpriority="high" decoding="async" class=" wp-image-137174 aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2025/01/CVM-41A-StrainVoltageAcceleration.png" alt="" width="333" height="220" srcset="https://koueitrading.com/global/wp-content/uploads/2025/01/CVM-41A-StrainVoltageAcceleration.png 575w, https://koueitrading.com/global/wp-content/uploads/2025/01/CVM-41A-StrainVoltageAcceleration-300x198.png 300w, https://koueitrading.com/global/wp-content/uploads/2025/01/CVM-41A-StrainVoltageAcceleration-180x118.png 180w" sizes="(max-width: 333px) 100vw, 333px" /></p>
<h2>Feature of CVM-41A Strain/Voltage/Acceleration</h2>
<p>You can select according to the application. In addition to strain, voltage, acceleration, and temperature measurements, CAN data is also supported. Furthermore, noise-resistant isolation amplifier cards are available. Additionally, dynamic strain measurement cards are offered, enhancing the versatility and utility of the system.</p>
<h2>Specification</h2>
<table>
<tbody>
<tr>
<th colspan="1" rowspan="1">&nbsp;</th>
<th colspan="1" rowspan="1"><strong>Strain measurement</strong></th>
<th colspan="1" rowspan="1"><strong>Voltage measurement</strong></th>
<th colspan="1" rowspan="1"><strong>Acceleration measurement (Piezoelectric)</strong></th>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>Applicable Recorders</strong></th>
<td colspan="3" rowspan="1">EDX-100A, EDX-200A, EDX-5000A</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>Channels</strong></th>
<td colspan="3" rowspan="1">8</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>Measuring Targets</strong></th>
<td colspan="1" rowspan="1">Strain gages, strain-gage transducers<br />
* For strain measurement, use bridge boxes</td>
<td colspan="1" rowspan="1">Voltage<br />
Voltage-output sensors</td>
<td colspan="1" rowspan="1">Piezoelectric accelerometers (Built-in amplifier)</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>Input Modes</strong></th>
<td colspan="1" rowspan="1">[Strain measurement]<br />
Balanced differential input</td>
<td colspan="1" rowspan="1">Balanced differential input<br />
*When using the Conversion Adapter FV-1A, this becomes unbalanced input<br />
*Common mode input voltage range ±20 VDC, absolute input voltage range ±50 V</td>
<td colspan="1" rowspan="1">Unbalanced input<br />
*Conversion Adapter FV-1A usage possible</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>Input Impedance</strong></th>
<td colspan="1" rowspan="1">&#8211;</td>
<td colspan="1" rowspan="1">1 MΩ + 1 MΩ<br />
Within ±10%<br />
*When using Conversion Adapter FV-1A (At unbalanced input), within 1 MΩ ±10%</td>
<td colspan="1" rowspan="1">&#8211;</td>
</tr>
<tr>
<th colspan="1" rowspan="2"><strong>Bridge Excitation or Power Supply to Sensors</strong></th>
<td colspan="1" rowspan="1">Const. voltage output<br />
BV2V: 2 VDC<br />
BV5V: 5 VDC<br />
BV10V: 10 VDC</td>
<td colspan="1" rowspan="1">Const. voltage output<br />
BV2V: 2 VDC (±1 V)<br />
BV5V: 5 VDC (±2.5 V)<br />
BV10V: 10 VDC (±5 V) or OFF<br />
20 mA/channels or less</td>
<td colspan="1" rowspan="1">Const. current output (Approx. 4 mA)<br />
(Excitation voltage: Approx. 23 VDC, Load: 1 kΩ or less)</td>
</tr>
<tr>
<td colspan="3" rowspan="1">*Each channel settable.<br />
The max. channels of CVM-41A in EDX-100A is 3 times of units of CVM</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>Gage Factor</strong></th>
<td colspan="1" rowspan="1">2.00 fixed</td>
<td colspan="1" rowspan="1">&#8211;</td>
<td colspan="1" rowspan="1">&#8211;</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>Compatible Bridge Resistance</strong></th>
<td colspan="1" rowspan="1">BV2V: 120 to 1000 Ω<br />
BV5V: 350 to 1000 Ω<br />
BV10V: 500 to 1000 Ω</td>
<td colspan="1" rowspan="1">&#8211;</td>
<td colspan="1" rowspan="1">&#8211;</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>Balance Operation Settings(Zero suppression)</strong></th>
<td colspan="1" rowspan="1">&#8212;&#8212;-Autobalance enabled<br />
Cancel the unbalanced bridge portion in the analog circuit, and zero the measurement value.<br />
&#8212;&#8212;-Autobalance disabled<br />
Do not cancel the unbalanced bridge portion<br />
(The initial unbalanced value in the bridge circuit can be confirmed)</td>
<td colspan="1" rowspan="1">&#8212;&#8212;-Zero suppression enabled<br />
Cancel the input voltage in the analog circuit, and zero the measurement value<br />
&#8212;&#8212;-Zero suppression disabled<br />
Do not cancel the input voltage in the analog circuit<br />
(Display the input voltage as is)</td>
<td colspan="1" rowspan="1">&#8211;</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>Balance Adjustment Range</strong></th>
<td colspan="1" rowspan="1">BV2V: Resistance ±10% (±50k ×10<span class="rich_text-sup">-6</span> strain)<br />
BV5V: Resistance ±4% (±20k ×10<span class="rich_text-sup">-6</span> strain)<br />
BV10V: Resistance ±2% (±10k ×10<span class="rich_text-sup">-6</span> strain)</td>
<td colspan="1" rowspan="1">±5 V</td>
<td colspan="1" rowspan="1">&#8211;</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>Measuring Range</strong></th>
<td colspan="1" rowspan="1">BV2V: 5 k, 10 k, 20 k, 50 k, 100 k, 200 k, 500 k ×10<span class="rich_text-sup">-6</span> strain<br />
BV5V: 5 k, 10 k, 20 k, 50 k, 100 k, 200 k ×10<span class="rich_text-sup">-6</span> strain<br />
BV10V: 2 k, 5 k, 10 k, 20 k, 50 k, 100 k ×10<span class="rich_text-sup">-6</span> strain</td>
<td colspan="1" rowspan="1">1, 2, 5, 10, 20, and 50 V</td>
<td colspan="1" rowspan="1">100, 200, 500, 1000, 2000, and 5000 mV</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>Range Accuracy</strong></th>
<td colspan="2" rowspan="1">Within ±0.2%FS</td>
<td colspan="1" rowspan="1">Within ±1.0%FS</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>Nonlinearity</strong></th>
<td colspan="2" rowspan="1">Within ±0.1%FS</td>
<td colspan="1" rowspan="1">Within ±0.2%FS</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>Calibration (CAL)SHUNT CAL</strong></th>
<td colspan="1" rowspan="1">±100% and ±50% of each range and SHUNT<br />
*When SHUNT CAL has 350 Ω load connected, approx. 257 ×10<span class="rich_text-sup">-6</span> strain output.</td>
<td colspan="1" rowspan="1">±100% and ±50% of each range</td>
<td colspan="1" rowspan="1">±100% and ±50% of each range</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>Frequency Response</strong></th>
<td colspan="2" rowspan="1">DC coupling: DC to 5 kHz, deviation +1dB, -3dB<br />
AC coupling: 0.2, 1 Hz to 5 kHz (See the HPF.)</td>
<td colspan="1" rowspan="1">0.5 Hz to 5 kHz, deviation +1dB, -3dB</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>LPF</strong></th>
<td colspan="3" rowspan="1">Transfer characteristics : 5 Butterworth type<br />
Cutoff frequencies : 30, 100, 300, 1 k, 3 k Hz, FLAT and AUTO<br />
*With AUTO settings, the cutoff frequency is set to 1/4 of the sampling frequency.<br />
Cutoff accuracy : Within -3 ±1 dB<br />
Attenuation : -30 (+3, -7) dB /oct.</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>HPF</strong></th>
<td colspan="1" rowspan="1">Cutoff frequencies: 0.2 Hz, 1 Hz<br />
Attenuation: -6 dB/oct.</td>
<td colspan="1" rowspan="1">Cutoff frequencies: 0.2 Hz, 1 Hz<br />
Attenuation: -6 dB/oct.</td>
<td colspan="1" rowspan="1">&#8211;</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>Resolution</strong></th>
<td colspan="3" rowspan="1">24 bits<br />
*When installed in EDX-100A, its resolution becomes 16 bits.</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>Distortion Rate</strong></th>
<td colspan="1" rowspan="1">&#8211;</td>
<td colspan="1" rowspan="1">&#8211;</td>
<td colspan="1" rowspan="1">1% or less</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>Monitor Output</strong></th>
<td colspan="3" rowspan="1">Accuracy: Within ±5 V ±0.5% (With ±FS)<br />
Nonlinearity: Within ±0.5%FS</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>Dimensions</strong></th>
<td colspan="3" rowspan="1">22 W x 119 H x 213 D mm (Excluding protrusions)</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>Weight</strong></th>
<td colspan="3" rowspan="1">Approx. 400 g</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>TEDS</strong></th>
<td colspan="3" rowspan="1">Reads information from TEDS-installed sensors.</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>Compliance</strong></th>
<td colspan="3" rowspan="1">Directive 2014/30/EU (EMC)<br />
Directive 2011/65/EU, (EU) 2015/863 (10 restricted substances) (RoHS)</td>
</tr>
</tbody>
</table>
<div data-table="">
<table>
<tbody>
<tr>
<th colspan="1" rowspan="1"><strong>Standard Accessories</strong></th>
<td colspan="1" rowspan="1">2 cross recessed binding head screw M3x6</td>
</tr>
<tr>
<th colspan="1" rowspan="1"><strong>Optional Accessories</strong></th>
<td colspan="1" rowspan="1">CCA input cable U-111<br />
CVM input cable U-121 to U-123<br />
CVM input integrated cable N-121<br />
Integrated output cable U-62<br />
Conversion adapter FV-1A<br />
Voltage input box VI-8A (-T)<br />
Bridge box for quarter bridge system<br />
DBS-120B-8 (C) (T)<br />
DBS-350B-8 (C) (T)<br />
One-touch type bridge box<br />
DBV-120A-8 (C)<br />
DBV-350A-8 (C)</td>
</tr>
</tbody>
</table>
</div>The post <a href="https://koueitrading.com/global/product/kyowa-cvm-41a-strain-voltage-acceleration-measurement-card-edx-series-conditioner-card/">Kyowa CVM-41A Strain/Voltage/Acceleration Measurement Card EDX Series Conditioner Card</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>