<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Solenoid Valves | Kouei Japan Trading | Get Quotation</title>
	<atom:link href="https://koueitrading.com/global/product-cat/solenoid-valves/feed/" rel="self" type="application/rss+xml" />
	<link>https://koueitrading.com/global</link>
	<description>Purchase tools and equipments made in Japan</description>
	<lastBuildDate>Mon, 16 Mar 2026 03:12:11 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.5</generator>

<image>
	<url>https://koueitrading.com/global/wp-content/uploads/2018/01/cropped-KoueiVietnam-logo-32x32.png</url>
	<title>Solenoid Valves | Kouei Japan Trading | Get Quotation</title>
	<link>https://koueitrading.com/global</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>KONAN MVW7(R) 2-Position, 3-Port Solenoid Valves</title>
		<link>https://koueitrading.com/global/product/konan-mvw7r%ef%bc%892-position-3-port-solenoid-valves/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Sat, 14 Mar 2026 22:30:21 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25529</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: MVW7(R) Specifications Model MVW71（R） MVW7（R） Port size Rc3/8 Rc1/2 Rc3/4 Rc1 Working pressure MVW71 MVW7 0.12 〜 0.7MPa MVW71R MVW7R 0.2 〜 0.7MPa Fluid temperature — 20 〜 60℃ Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower. Ambient temperature — [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-mvw7r%ef%bc%892-position-3-port-solenoid-valves/">KONAN MVW7(R) 2-Position, 3-Port Solenoid Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: MVW7(R)</p>
<h1>Specifications</h1>
<table>
<tbody>
<tr>
<td colspan="2" width="189">Model</td>
<td colspan="5" width="248">MVW71（R）</td>
<td colspan="4" width="248">MVW7（R）</td>
</tr>
<tr>
<td colspan="2" width="189">Port size</td>
<td width="124">Rc3/8</td>
<td colspan="4" width="124">Rc1/2</td>
<td colspan="2" width="124">Rc3/4</td>
<td colspan="2" width="124">Rc1</td>
</tr>
<tr>
<td rowspan="2" width="102">Working pressure</td>
<td width="87">MVW71 MVW7</td>
<td colspan="9" width="495">0.12 〜 0.7MPa</td>
</tr>
<tr>
<td width="87">MVW71R MVW7R</td>
<td colspan="9" width="495">0.2 〜 0.7MPa</td>
</tr>
<tr>
<td colspan="2" width="189">Fluid temperature</td>
<td colspan="4" width="211">— 20 〜 60℃</td>
<td colspan="5" rowspan="2" width="284">Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.</td>
</tr>
<tr>
<td colspan="2" width="189">Ambient temperature</td>
<td colspan="4" width="211">— 20 〜 50℃</td>
</tr>
<tr>
<td colspan="2" width="189">Effective sectional area</td>
<td width="124">65mm<sup>2</sup></td>
<td colspan="4" width="124">75mm<sup>2</sup></td>
<td colspan="2" width="124">160mm<sup>2</sup></td>
<td colspan="2" width="124">190mm<sup>2</sup></td>
</tr>
<tr>
<td rowspan="2" width="102">Response time</td>
<td width="87">AC</td>
<td colspan="2" width="136">0.03s 以下</td>
<td width="55">≦ 0.03 s</td>
<td colspan="2" width="57"></td>
<td width="53"></td>
<td colspan="2" width="83">0.05s 以下</td>
<td width="111">≦ 0.05 s</td>
</tr>
<tr>
<td width="87">DC</td>
<td colspan="2" width="136">0.04s 以下</td>
<td width="55">≦ 0.04 s</td>
<td colspan="2" width="57"></td>
<td width="53"></td>
<td colspan="2" width="83">0.065s 以下</td>
<td width="111">≦ 0.065 s</td>
</tr>
<tr>
<td colspan="2" width="189">最高使用頻度 Max. operating frequency</td>
<td colspan="2" width="136"></td>
<td width="55"></td>
<td colspan="2" width="57">1 回 /s</td>
<td width="53">1 cycle /s</td>
<td colspan="2" width="83"></td>
<td width="111"></td>
</tr>
<tr>
<td colspan="2" width="189">Internal leakage</td>
<td colspan="9" width="495">JIS B 8373：2015 Less than value of the standard</td>
</tr>
<tr>
<td colspan="2" width="189">Installation position</td>
<td colspan="9" width="495">Free</td>
</tr>
<tr>
<td colspan="2" width="189">Mass</td>
<td colspan="5" width="248">2.1kg</td>
<td colspan="4" width="248">3.8kg</td>
</tr>
</tbody>
</table>
<h1>Model Code</h1>
<p><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-25519" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-87.png" alt="" width="1021" height="627" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-87.png 1021w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-87-300x184.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-87-768x472.png 768w" sizes="(max-width: 1021px) 100vw, 1021px" /></p>
<p><img decoding="async" class="alignnone size-full wp-image-25520" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-51.png" alt="" width="982" height="407" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-51.png 982w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-51-300x124.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-51-768x318.png 768w" sizes="(max-width: 982px) 100vw, 982px" /></p>
<h1>Operation</h1>
<p><img decoding="async" class="alignnone size-full wp-image-25522" src="https://koueitrading.com/global/wp-content/uploads/2021/02/1-51.png" alt="" width="1004" height="422" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/1-51.png 1004w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-51-300x126.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-51-768x323.png 768w" sizes="(max-width: 1004px) 100vw, 1004px" /></p>
<h1>External Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-25530" src="https://koueitrading.com/global/wp-content/uploads/2021/02/1-53.png" alt="" width="825" height="806" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/1-53.png 825w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-53-300x293.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-53-768x750.png 768w" sizes="auto, (max-width: 825px) 100vw, 825px" /></p>
<h1>Structure</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25531 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/2-35.png" alt="MVW7(R)" width="923" height="755" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/2-35.png 923w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-35-300x245.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-35-768x628.png 768w" sizes="auto, (max-width: 923px) 100vw, 923px" /></p>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25532 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/3-11.png" alt="MVW7(R)" width="925" height="482" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/3-11.png 925w, https://koueitrading.com/global/wp-content/uploads/2021/02/3-11-300x156.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/3-11-768x400.png 768w" sizes="auto, (max-width: 925px) 100vw, 925px" /></p>
<h1>Parts</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25533 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/5-2.png" alt="MVW7(R)" width="501" height="313" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/5-2.png 501w, https://koueitrading.com/global/wp-content/uploads/2021/02/5-2-300x187.png 300w" sizes="auto, (max-width: 501px) 100vw, 501px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-25534 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/4-12.png" alt="MVW7(R)" width="1032" height="688" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/4-12.png 1032w, https://koueitrading.com/global/wp-content/uploads/2021/02/4-12-300x200.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/4-12-1024x683.png 1024w, https://koueitrading.com/global/wp-content/uploads/2021/02/4-12-768x512.png 768w" sizes="auto, (max-width: 1032px) 100vw, 1032px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-mvw7r%ef%bc%892-position-3-port-solenoid-valves/">KONAN MVW7(R) 2-Position, 3-Port Solenoid Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN MVS2F/MVD2F Series 5-Port Solenoid Valves Drip-proof Type</title>
		<link>https://koueitrading.com/global/product/konan-mvs2f-mvd2f-series-5-port-solenoid-valves-drip-proof-type/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Sun, 02 Mar 2025 01:35:23 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25392</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: MVS2F/MVD2F Series : MVS2F-03-E3K, MVD2F-03-E3K Specifications Return Hold Return Hold Type   Explosion-proof type   Pressure-resistant packing MVS2F-03-E2K MVS2F-03-E2E MVS2F-03-E2Y MVD2F-03-E2K MVD2F-03-E2E MVS2N-08-E2K MVS2N-08-E2E MVS2N-08-E2Y MVD2N-08-E2K MVD2N-08-E2E Conduit tube MVS2F-03-E1K MVS2F-03-E1E MVD2F-03-E1K MVD2F-03-E1E MVS2N-08-E1K MVS2N-08-E1E MVD2N-08-E1K MVD2N-08-E1E Drip-proof type MVS2F-03-E3K MVD2F-03-E3K MVS2N-08-E3K MVD2N-08-E3K Port size（Rc） 1/4・3/8・1/2 3/4・1 [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-mvs2f-mvd2f-series-5-port-solenoid-valves-drip-proof-type/">KONAN MVS2F/MVD2F Series 5-Port Solenoid Valves Drip-proof Type</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: MVS2F/MVD2F Series : MVS2F-03-E3K, MVD2F-03-E3K</p>
<h1>Specifications</h1>
<table>
<tbody>
<tr>
<td colspan="3" width="193"></td>
<td width="123">Return</td>
<td width="123">Hold</td>
<td width="123">Return</td>
<td width="123">Hold</td>
</tr>
<tr>
<td rowspan="3" width="26">Type</td>
<td rowspan="2" width="53"><strong> </strong></p>
<p>Explosion-proof type</td>
<td width="113"><strong> </strong></p>
<p>Pressure-resistant packing</td>
<td width="123">MVS2F-03-E2K MVS2F-03-E2E MVS2F-03-E2Y</td>
<td width="123">MVD2F-03-E2K MVD2F-03-E2E</td>
<td width="123">MVS2N-08-E2K MVS2N-08-E2E MVS2N-08-E2Y</td>
<td width="123">MVD2N-08-E2K MVD2N-08-E2E</td>
</tr>
<tr>
<td width="113">Conduit tube</td>
<td width="123">MVS2F-03-E1K MVS2F-03-E1E</td>
<td width="123">MVD2F-03-E1K MVD2F-03-E1E</td>
<td width="123">MVS2N-08-E1K MVS2N-08-E1E</td>
<td width="123">MVD2N-08-E1K MVD2N-08-E1E</td>
</tr>
<tr>
<td colspan="2" width="166">Drip-proof type</td>
<td width="123">MVS2F-03-E3K</td>
<td width="123">MVD2F-03-E3K</td>
<td width="123">MVS2N-08-E3K</td>
<td width="123">MVD2N-08-E3K</td>
</tr>
<tr>
<td colspan="3" width="193">Port size（Rc）</td>
<td colspan="2" width="246">1/4・3/8・1/2</td>
<td colspan="2" width="246">3/4・1</td>
</tr>
<tr>
<td colspan="3" width="193">Effective sectional area（CV value）</td>
<td colspan="2" width="246">40㎟（2.2）・55㎟（3.0）・70㎟（3.8）</td>
<td colspan="2" width="246">175㎟（9.5）・185㎟（10.0）</td>
</tr>
<tr>
<td colspan="3" rowspan="2" width="193"><strong> </strong></p>
<p>Operating pressure</td>
<td colspan="2" width="246">0.2 〜 0.7MPa</td>
<td colspan="2" width="246">0.12 〜 0.7MPa</td>
</tr>
<tr>
<td colspan="4" width="491">In the case of separate pilot supply types Pilot operating pressure ≧ Operating pressure</td>
</tr>
<tr>
<td colspan="3" width="193">Pressure resistance</td>
<td colspan="4" width="491">1.05MPa</td>
</tr>
<tr>
<td colspan="3" width="193">Operating temperature</td>
<td colspan="2" width="246">－5〜 60℃</td>
<td colspan="2" width="246">— 20 〜 50℃</td>
</tr>
<tr>
<td colspan="3" width="193">Operating frequency</td>
<td colspan="4" width="491">1 cycle / s max.       /      1 cycle / 6 months min.</td>
</tr>
<tr>
<td colspan="3" width="193">Operation（response）time</td>
<td colspan="2" width="246">0.1 s max.</td>
<td colspan="2" width="246">0.3 s max.</td>
</tr>
<tr>
<td rowspan="7" width="26">Solenoid</td>
<td colspan="2" width="166">Rated voltage</td>
<td colspan="4" width="491">Refer to Model Code</td>
</tr>
<tr>
<td colspan="2" width="166">Voltage fluctuation tolerance</td>
<td colspan="4" width="491">— 15％〜 10％ of rated voltage</td>
</tr>
<tr>
<td colspan="2" width="166">Temperature rise</td>
<td width="123">80 deg max.</td>
<td width="123">65 deg max.</td>
<td width="123">80 deg max.</td>
<td width="123">65 deg max.</td>
</tr>
<tr>
<td colspan="2" width="166">Insulation class</td>
<td colspan="4" width="491">Class H</td>
</tr>
<tr>
<td colspan="2" width="166">Insulation resistance</td>
<td colspan="4" width="491">10MΩ min.</td>
</tr>
<tr>
<td colspan="2" width="166">Rated current</td>
<td colspan="4" width="491">Refer to Rated current data on page A-39</td>
</tr>
<tr>
<td colspan="2" width="166">Explosion-proof standard</td>
<td colspan="4" width="491">Flame-proof enclosure construction d2G4 / Exd Ⅱ BT4</td>
</tr>
<tr>
<td colspan="3" width="193">Mass</td>
<td colspan="2" width="246">Approx. 3.0kg</td>
<td colspan="2" width="246">Approx. 5.0kg</td>
</tr>
</tbody>
</table>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25382 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-74.png" alt="MVS2F/MVD2F Series : MVS2F-03-E3K, MVD2F-03-E3K" width="896" height="171" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-74.png 896w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-74-300x57.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-74-768x147.png 768w" sizes="auto, (max-width: 896px) 100vw, 896px" /></p>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25383 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-35.png" alt="MVS2F/MVD2F Series : MVS2F-03-E3K, MVD2F-03-E3K" width="922" height="631" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-35.png 922w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-35-300x205.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-35-768x526.png 768w" sizes="auto, (max-width: 922px) 100vw, 922px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-25384 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-41.png" alt="MVS2F/MVD2F Series : MVS2F-03-E3K, MVD2F-03-E3K" width="940" height="589" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-41.png 940w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-41-300x188.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-41-768x481.png 768w" sizes="auto, (max-width: 940px) 100vw, 940px" /></p>
<h1>Outside Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-25393" src="https://koueitrading.com/global/wp-content/uploads/2021/02/1-32.png" alt="" width="453" height="484" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/1-32.png 453w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-32-281x300.png 281w" sizes="auto, (max-width: 453px) 100vw, 453px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-25394 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/2-22.png" alt="MVS2F/MVD2F Series : MVS2F-03-E3K, MVD2F-03-E3K" width="490" height="486" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/2-22.png 490w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-22-300x298.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-22-150x150.png 150w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-22-72x72.png 72w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-22-120x120.png 120w" sizes="auto, (max-width: 490px) 100vw, 490px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-mvs2f-mvd2f-series-5-port-solenoid-valves-drip-proof-type/">KONAN MVS2F/MVD2F Series 5-Port Solenoid Valves Drip-proof Type</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN NC302 2-port Solenoid Valves For Nuclear Power Plants Normally Open</title>
		<link>https://koueitrading.com/global/product/konan-nc302-2-port-solenoid-valves-for-nuclear-power-plants-normally-open/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Wed, 10 Mar 2021 07:17:49 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=26278</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: NC302 N30 series 2-port solenoid valves for nuclear power plants are small size direct-acting valves incorporating soft seal.The space-saving compact valves are provided with brass or stainless steel body for control of various fluids in NB/NC applications. Specification Model code NB/NC301 NC302 Valve operation type Normally closedC [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-nc302-2-port-solenoid-valves-for-nuclear-power-plants-normally-open/">KONAN NC302 2-port Solenoid Valves For Nuclear Power Plants Normally Open</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: NC302</p>
<p>N30 series 2-port solenoid valves for nuclear power plants are small size direct-acting valves incorporating soft seal.The space-saving compact valves<br />
are provided with brass or stainless steel body for control of various fluids in NB/NC applications.</p>
<h1>Specification</h1>
<table>
<tbody>
<tr>
<th colspan="4">Model code</th>
<td colspan="6">NB/NC301</td>
<td colspan="2">NC302</td>
</tr>
<tr>
<th colspan="4">Valve operation type</th>
<td colspan="6">Normally closedC</td>
<td colspan="2">Normally open</td>
</tr>
<tr>
<th colspan="4">Port size</th>
<td colspan="6">Rc1/4</td>
<td colspan="2">Rc1/4</td>
</tr>
<tr>
<th colspan="4">Orifice size（mm）</th>
<td>1.2</td>
<td>1.6</td>
<td>2.4</td>
<td>3.2</td>
<td>4.0</td>
<td>4.8</td>
<td>2.4</td>
<td>3.2</td>
</tr>
<tr>
<th colspan="4">Cv value</th>
<td>0.05</td>
<td>0.1</td>
<td>0.21</td>
<td>0.36</td>
<td>0.44</td>
<td>0.65</td>
<td>0.21</td>
<td>0.36</td>
</tr>
<tr>
<th rowspan="3">Operating<br />
pressure<br />
differential<br />
（MPa）</th>
<th colspan="3">Min.</th>
<td colspan="6">0</td>
<td colspan="2">0</td>
</tr>
<tr>
<th rowspan="2">Max.</th>
<th rowspan="2">Air/Inert gas</th>
<th>AC</th>
<td>7.20</td>
<td>4.80</td>
<td>2.74</td>
<td>1.37</td>
<td>1.02</td>
<td>0.68</td>
<td>1.02</td>
<td>0.68</td>
</tr>
<tr>
<th>DC</th>
<td>6.86</td>
<td>2.05</td>
<td>1.37</td>
<td>0.96</td>
<td>0.68</td>
<td>0.48</td>
<td>1.02</td>
<td>0.68</td>
</tr>
<tr>
<th colspan="4">Body</th>
<td colspan="8">Brass , stainless steel</td>
</tr>
<tr>
<th colspan="4">Elastomer</th>
<td colspan="8">Nitrile rubber（only NC）,Fluorine rubber（only NB）,Ethylene propylene（only NB）</td>
</tr>
<tr>
<th colspan="4">Housing</th>
<td colspan="8">NEMA4 drip-proof</td>
</tr>
<tr>
<th rowspan="6">Solenoid</th>
<th colspan="2" rowspan="2">Applicable voltage</th>
<th>AC</th>
<td colspan="8">100V , 110V , 115V , 120V</td>
</tr>
<tr>
<th>DC</th>
<td colspan="8">100V , 110V , 125V</td>
</tr>
<tr>
<th colspan="3">Allowable voltage fluctuation</th>
<td colspan="8">-15% to 10% of applicable voltage</td>
</tr>
<tr>
<th colspan="3">Insulation class</th>
<td colspan="8">Class H</td>
</tr>
<tr>
<th colspan="3">Leadwire length（mm）</th>
<td colspan="8">600</td>
</tr>
<tr>
<th colspan="3">Ambient temperature</th>
<td colspan="8">Refer to catalog for details.</td>
</tr>
<tr>
<th colspan="4">Installation position</th>
<td colspan="8">As desired（Horizontal mounting with solenoid at upper side is recommended）</td>
</tr>
<tr>
<th colspan="4">Options</th>
<td colspan="8">Terminal box , NPT（port）</td>
</tr>
</tbody>
</table>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-26279" src="https://koueitrading.com/global/wp-content/uploads/2021/03/1.png" alt="" width="886" height="537" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/1.png 886w, https://koueitrading.com/global/wp-content/uploads/2021/03/1-300x182.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/03/1-768x465.png 768w" sizes="auto, (max-width: 886px) 100vw, 886px" /></p>
<h1>External Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-26280 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/03/2.png" alt="NC302" width="858" height="476" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/2.png 858w, https://koueitrading.com/global/wp-content/uploads/2021/03/2-300x166.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/03/2-768x426.png 768w" sizes="auto, (max-width: 858px) 100vw, 858px" /></p>
<h1>JIS Symbols</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-26275 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/03/Capture.png" alt="NC302" width="339" height="137" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/Capture.png 339w, https://koueitrading.com/global/wp-content/uploads/2021/03/Capture-300x121.png 300w" sizes="auto, (max-width: 339px) 100vw, 339px" /></p>
<h1>Coil Data</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-26276 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/03/Capture1.png" alt="NC302" width="465" height="226" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/Capture1.png 465w, https://koueitrading.com/global/wp-content/uploads/2021/03/Capture1-300x146.png 300w" sizes="auto, (max-width: 465px) 100vw, 465px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-nc302-2-port-solenoid-valves-for-nuclear-power-plants-normally-open/">KONAN NC302 2-port Solenoid Valves For Nuclear Power Plants Normally Open</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN MAGSTER ⅡF MVD2F-03 5 Port Solenoid Valves Gasket-connected Type 2 Positions Hold</title>
		<link>https://koueitrading.com/global/product/konan-magster-%e2%85%b1f-mvd2f-03%e3%83%bb08-5-port-solenoid-valves-gasket-connected-type-2-positions-hold/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Wed, 10 Mar 2021 07:00:19 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=24713</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: MVD2F-03 Specifications &#160; Model code Return MVS2F-03 MVS2F-08 Hold MVD2F-03 MVD2F-08 Closed center MVPCF-03 MVPCF-08 The center open to exhaust MVPOF-03 MVPOF-08 Centre open to pressure MVPEF-03 MVPEF-08 Port size Rc 1/4 Rc 3/8 Rc 1/2 Rc 3/4 Rc 1 Effective sectional area 40㎜2 55㎜2 70㎜2 175㎜2 [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-magster-%e2%85%b1f-mvd2f-03%e3%83%bb08-5-port-solenoid-valves-gasket-connected-type-2-positions-hold/">KONAN MAGSTER ⅡF MVD2F-03 5 Port Solenoid Valves Gasket-connected Type 2 Positions Hold</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: MVD2F-03</p>
<h1><strong><em>Specifications</em></strong></h1>
<table>
<tbody>
<tr>
<td colspan="2" rowspan="5" width="76">&nbsp;</p>
<p>Model code</td>
<td width="110">Return</td>
<td colspan="5" width="297">MVS2F-03</td>
<td colspan="2" width="198">MVS2F-08</td>
</tr>
<tr>
<td width="110">Hold</td>
<td colspan="5" width="297">MVD2F-03</td>
<td colspan="2" width="198">MVD2F-08</td>
</tr>
<tr>
<td width="110">Closed center</td>
<td colspan="5" width="297">MVPCF-03</td>
<td colspan="2" width="198">MVPCF-08</td>
</tr>
<tr>
<td width="110">The center open to exhaust</td>
<td colspan="5" width="297">MVPOF-03</td>
<td colspan="2" width="198">MVPOF-08</td>
</tr>
<tr>
<td width="110">Centre open to pressure</td>
<td colspan="5" width="297">MVPEF-03</td>
<td colspan="2" width="198">MVPEF-08</td>
</tr>
<tr>
<td colspan="3" width="185">Port size</td>
<td colspan="2" width="99">Rc 1/4</td>
<td width="99">Rc 3/8</td>
<td colspan="2" width="99">Rc 1/2</td>
<td width="99">Rc 3/4</td>
<td width="99">Rc 1</td>
</tr>
<tr>
<td colspan="3" width="185">Effective sectional area</td>
<td colspan="2" width="99">40㎜2</td>
<td width="99">55㎜2</td>
<td colspan="2" width="99">70㎜2</td>
<td width="99">175㎜2</td>
<td width="99">185㎜2</td>
</tr>
<tr>
<td colspan="3" rowspan="2" width="185">&nbsp;</p>
<p>Operating pressure</td>
<td colspan="5" width="297">0 ～ 0.8MPa</td>
<td colspan="2" width="198">0.12 ～ 0.7MPa</td>
</tr>
<tr>
<td colspan="7" width="495">Case of external pilot type</p>
<p>Pilot operating pressure  ≧      Operating pressure</td>
</tr>
<tr>
<td colspan="3" width="185">Proof pressure</td>
<td colspan="5" width="297">1.2MPa</td>
<td colspan="2" width="198">1.05MPa</td>
</tr>
<tr>
<td colspan="3" width="185">Fluid temperature</td>
<td width="82">ー5～ 50℃</td>
<td colspan="3" rowspan="2" width="206">Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.</td>
<td width="10"></td>
<td colspan="2" width="198">— 20 ～ 50℃ Remove moisture perfectly from the fluid to</td>
</tr>
<tr>
<td colspan="3" width="185">Ambient temperature</td>
<td width="82">ー5～ 50℃</td>
<td width="10"></td>
<td colspan="2" width="198">— 20 ～ 50℃ prevent freezing when used at 5℃ or lower.</td>
</tr>
<tr>
<td rowspan="5" width="19">Solenoid</td>
<td colspan="2" width="166">Rated voltage</td>
<td colspan="7" width="495">See model code section.</td>
</tr>
<tr>
<td colspan="2" width="166">Allowable votage fluctuation</td>
<td colspan="7" width="495">± 10% of applicable voltage</td>
</tr>
<tr>
<td colspan="2" width="166">Temperature rise</td>
<td colspan="7" width="495">Max. 80℃（Resistance method）</td>
</tr>
<tr>
<td colspan="2" width="166">Insulation class</td>
<td colspan="7" width="495">JIS C 4003 Class B</td>
</tr>
<tr>
<td colspan="2" width="166">Power consumption</td>
<td colspan="7" width="495">AC……10VA             DC……6W</td>
</tr>
<tr>
<td colspan="3" width="185">Response time</td>
<td colspan="5" width="297">AC……Less than 0.03s     DC less than 0.05s</td>
<td colspan="2" width="198">AC……Less than 0.07s DC Less than 0.05s</td>
</tr>
<tr>
<td colspan="3" width="185">Performance frequency</td>
<td colspan="7" width="495">Max. 4 cycle/s           Min. 1 cycle/6 mon.</td>
</tr>
<tr>
<td colspan="3" width="185">Mass</td>
<td colspan="5" width="297">Return……0.4 ㎏ Other……1.6 ㎏</td>
<td colspan="2" width="198">Return……4.5 ㎏ Other……5 ㎏</td>
</tr>
</tbody>
</table>
<h1></h1>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-24704 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-13.png" alt="MVD2F-03" width="1330" height="809" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-13.png 1330w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-13-300x182.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-13-1024x623.png 1024w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-13-768x467.png 768w" sizes="auto, (max-width: 1330px) 100vw, 1330px" /></p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-24705" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-45.png" alt="" width="1323" height="148" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-45.png 1323w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-45-300x34.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-45-1024x115.png 1024w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-45-768x86.png 768w" sizes="auto, (max-width: 1323px) 100vw, 1323px" /></p>
<h1>External  Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-24727" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-16.png" alt="" width="327" height="402" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-16.png 327w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-16-244x300.png 244w" sizes="auto, (max-width: 327px) 100vw, 327px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-24728 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-15.png" alt="MVD2F-03" width="398" height="402" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-15.png 398w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-15-297x300.png 297w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-15-72x72.png 72w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-15-120x120.png 120w" sizes="auto, (max-width: 398px) 100vw, 398px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-24729 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-48.png" alt="MVD2F-03" width="847" height="844" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-48.png 847w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-48-300x300.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-48-150x150.png 150w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-48-768x765.png 768w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-48-72x72.png 72w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-48-200x200.png 200w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-48-120x120.png 120w" sizes="auto, (max-width: 847px) 100vw, 847px" /></p>
<h1>DIN connector（Option）Installation</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-24708 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-8.png" alt="MVD2F-03" width="1332" height="385" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-8.png 1332w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-8-300x87.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-8-1024x296.png 1024w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-8-768x222.png 768w" sizes="auto, (max-width: 1332px) 100vw, 1332px" /></p>
<h1>Actuation</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-24718 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/1-1.png" alt="MVD2F-03" width="1392" height="444" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/1-1.png 1392w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-1-300x96.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-1-1024x327.png 1024w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-1-768x245.png 768w" sizes="auto, (max-width: 1392px) 100vw, 1392px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-magster-%e2%85%b1f-mvd2f-03%e3%83%bb08-5-port-solenoid-valves-gasket-connected-type-2-positions-hold/">KONAN MAGSTER ⅡF MVD2F-03 5 Port Solenoid Valves Gasket-connected Type 2 Positions Hold</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN NB/NC202 2-port Solenoid Valves For Nuclear Power Plants Normally Open</title>
		<link>https://koueitrading.com/global/product/konan-nb-nc202-2-port-solenoid-valves-for-nuclear-power-plants-normally-open/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Wed, 10 Mar 2021 06:20:34 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=26287</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: NB/NC202 N20 series 2-port solenoid valves for nuclear power plants are pilot-type valves incorporating a hanging diaphragm that enables operation at zero differential pressure. Applicable pressure ranges from -100 KPa to 1.37MPa, and brass or stainless steel bodies can be selected for NC application for control of [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-nb-nc202-2-port-solenoid-valves-for-nuclear-power-plants-normally-open/">KONAN NB/NC202 2-port Solenoid Valves For Nuclear Power Plants Normally Open</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: NB/NC202</p>
<p>N20 series 2-port solenoid valves for nuclear power plants are pilot-type valves incorporating a hanging diaphragm that enables operation at zero differential pressure.<br />
Applicable pressure ranges from -100 KPa to 1.37MPa, and brass or stainless steel bodies can be selected for NC application for control of various fluids.</p>
<p>■Applicable fluid： Air / Inert gas<br />
■Valve type : NB/NC201（Normally closed type）　NB/NC202（Normally open type）<br />
■Operation type : Pilot (operates with no differential pressure)<br />
■Port size：Rc3/8 , Rc1/2 , Rc3/4</p>
<h1>Specification</h1>
<table>
<tbody>
<tr>
<th colspan="4">Model code</th>
<td colspan="3">NB/NC201</td>
<td colspan="3">NB/NC202</td>
</tr>
<tr>
<th colspan="4">Valve operation type</th>
<td colspan="3">Normally closed</td>
<td colspan="3">Normally open</td>
</tr>
<tr>
<th colspan="4">Port size</th>
<td>Rc3/8</td>
<td>Rc1/2</td>
<td>Rc3/4</td>
<td>Rc3/8</td>
<td>Rc1/2</td>
<td>Rc3/4</td>
</tr>
<tr>
<th colspan="4">Orifice size（mm）</th>
<td colspan="2">15.9</td>
<td>19.1</td>
<td colspan="2">15.9</td>
<td>19.1</td>
</tr>
<tr>
<th colspan="4">Cv value</th>
<td>3.3</td>
<td>4.1</td>
<td>5.5</td>
<td>3.3</td>
<td>4.1</td>
<td>5.5</td>
</tr>
<tr>
<th rowspan="3">Operating<br />
pressure<br />
differential<br />
（MPa）</th>
<th colspan="3">Min.</th>
<td colspan="6">0</td>
</tr>
<tr>
<th rowspan="2">Max.</th>
<th rowspan="2">Air/Inert gas</th>
<th>AC</th>
<td colspan="3">0.96</td>
<td colspan="3">1.37</td>
</tr>
<tr>
<th>DC</th>
<td colspan="3">0.61</td>
<td colspan="3">0.86</td>
</tr>
<tr>
<th colspan="4">Body</th>
<td colspan="6">Brass , stainless steel</td>
</tr>
<tr>
<th colspan="4">Elastomer</th>
<td colspan="6">Nitrile rubber（only NC）,Fluorine rubber（only NB）,Ethylene propylene（only NB）</td>
</tr>
<tr>
<th colspan="4">Housing</th>
<td colspan="6">NEMA4 drip-proof</td>
</tr>
<tr>
<th rowspan="6">Solenoid</th>
<th colspan="2" rowspan="2">Applicable voltage</th>
<th>AC</th>
<td colspan="6">100V , 110V , 115V , 120V</td>
</tr>
<tr>
<th>DC</th>
<td colspan="6">100V , 110V , 125V</td>
</tr>
<tr>
<th colspan="3">Allowable voltage fluctuation</th>
<td colspan="6">-15% to 10% of applicable voltage</td>
</tr>
<tr>
<th colspan="3">Insulation class</th>
<td colspan="6">Class H</td>
</tr>
<tr>
<th colspan="3">Leadwire length（mm）</th>
<td colspan="6">600</td>
</tr>
<tr>
<th colspan="3">Ambient temperature</th>
<td colspan="6">Refer to catalog for details.</td>
</tr>
<tr>
<th colspan="4">Installation position</th>
<td colspan="6">As desired（Horizontal mounting with solenoid at upper side is recommended）</td>
</tr>
<tr>
<th colspan="4">Options</th>
<td colspan="6">Mounting bracket , NPT（port） , Terminal box , Manual operating system</td>
</tr>
</tbody>
</table>
<h1>External Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-26283 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/03/3.png" alt="NB/NC202" width="852" height="493" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/3.png 852w, https://koueitrading.com/global/wp-content/uploads/2021/03/3-300x174.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/03/3-768x444.png 768w" sizes="auto, (max-width: 852px) 100vw, 852px" /></p>
<h1>JIS Symbols</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-26284" src="https://koueitrading.com/global/wp-content/uploads/2021/03/1-1.png" alt="" width="328" height="135" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/1-1.png 328w, https://koueitrading.com/global/wp-content/uploads/2021/03/1-1-300x123.png 300w" sizes="auto, (max-width: 328px) 100vw, 328px" /></p>
<h1>Coil Data</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-26285 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/03/2-1.png" alt="NB/NC202" width="448" height="217" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/2-1.png 448w, https://koueitrading.com/global/wp-content/uploads/2021/03/2-1-300x145.png 300w" sizes="auto, (max-width: 448px) 100vw, 448px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-nb-nc202-2-port-solenoid-valves-for-nuclear-power-plants-normally-open/">KONAN NB/NC202 2-port Solenoid Valves For Nuclear Power Plants Normally Open</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN MAGSTER ⅡF AVPCF-03 5 Port Air Operated Valves Gasket-connected 3 Positions Closed Center Type</title>
		<link>https://koueitrading.com/global/product/konan-magster-%e2%85%b1f-avpcf-03-5-port-air-operated-valves-gasket-connected-3-positions-closed-centertype/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Wed, 10 Mar 2021 05:31:51 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=24992</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: AVPCF-03 Model Code Specification External Dimensions Kouei is Distributor/Agent of KONAN. Other items of KONAN. Request the quotation for KONAN. &#160;</p>
The post <a href="https://koueitrading.com/global/product/konan-magster-%e2%85%b1f-avpcf-03-5-port-air-operated-valves-gasket-connected-3-positions-closed-centertype/">KONAN MAGSTER ⅡF AVPCF-03 5 Port Air Operated Valves Gasket-connected 3 Positions Closed Center Type</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: AVPCF-03</p>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone  wp-image-95707" src="https://koueitrading.com/global/wp-content/uploads/2023/12/Screenshot-2023-12-12-090636-1024x618.png" alt="" width="1195" height="721" srcset="https://koueitrading.com/global/wp-content/uploads/2023/12/Screenshot-2023-12-12-090636-1024x618.png 1024w, https://koueitrading.com/global/wp-content/uploads/2023/12/Screenshot-2023-12-12-090636-300x181.png 300w, https://koueitrading.com/global/wp-content/uploads/2023/12/Screenshot-2023-12-12-090636-768x464.png 768w, https://koueitrading.com/global/wp-content/uploads/2023/12/Screenshot-2023-12-12-090636.png 1169w" sizes="auto, (max-width: 1195px) 100vw, 1195px" /></p>
<h1>Specification</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-large wp-image-95708" src="https://koueitrading.com/global/wp-content/uploads/2023/12/Screenshot-2023-12-12-091453-1024x286.png" alt="" width="1024" height="286" srcset="https://koueitrading.com/global/wp-content/uploads/2023/12/Screenshot-2023-12-12-091453-1024x286.png 1024w, https://koueitrading.com/global/wp-content/uploads/2023/12/Screenshot-2023-12-12-091453-300x84.png 300w, https://koueitrading.com/global/wp-content/uploads/2023/12/Screenshot-2023-12-12-091453-768x214.png 768w, https://koueitrading.com/global/wp-content/uploads/2023/12/Screenshot-2023-12-12-091453.png 1205w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /></p>
<h1>External Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-95709" src="https://koueitrading.com/global/wp-content/uploads/2023/12/Screenshot-2023-12-12-091520.png" alt="" width="957" height="614" srcset="https://koueitrading.com/global/wp-content/uploads/2023/12/Screenshot-2023-12-12-091520.png 957w, https://koueitrading.com/global/wp-content/uploads/2023/12/Screenshot-2023-12-12-091520-300x192.png 300w, https://koueitrading.com/global/wp-content/uploads/2023/12/Screenshot-2023-12-12-091520-768x493.png 768w" sizes="auto, (max-width: 957px) 100vw, 957px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>
<div id="gtx-trans" style="position: absolute; left: 43px; top: 88.6px;">
<div class="gtx-trans-icon"></div>
</div>The post <a href="https://koueitrading.com/global/product/konan-magster-%e2%85%b1f-avpcf-03-5-port-air-operated-valves-gasket-connected-3-positions-closed-centertype/">KONAN MAGSTER ⅡF AVPCF-03 5 Port Air Operated Valves Gasket-connected 3 Positions Closed Center Type</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN MAGSTER ⅡF MVW1F-02 3 Port Solenoid Valves Gasket-connected type Normally Closed</title>
		<link>https://koueitrading.com/global/product/konan-magster-%e2%85%b1f-mvw1f-02-3-port-solenoid-valves-gasket-connected-type-normally-closed/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Wed, 10 Mar 2021 05:27:59 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=24694</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECRIC Model: MVW1F-02 Model Code Specifications model code MVW1F -02 MVW1RF -02 Port size Rc 1/8・Rc 1/4・Rc 3/8 Effective sectional area 3.0 ㎜2 Operating pressure 0 ～ 0.8MPa Proof pressure 1.2MPa Fluid temperature — 20 ～ 50℃ Remove moisture perfectly from the fluid to                                                                                          prevent freezing when used [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-magster-%e2%85%b1f-mvw1f-02-3-port-solenoid-valves-gasket-connected-type-normally-closed/">KONAN MAGSTER ⅡF MVW1F-02 3 Port Solenoid Valves Gasket-connected type Normally Closed</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECRIC<br />
Model: MVW1F-02</p>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-24695" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-44.png" alt="" width="1338" height="770" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-44.png 1338w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-44-300x173.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-44-1024x589.png 1024w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-44-768x442.png 768w" sizes="auto, (max-width: 1338px) 100vw, 1338px" /></p>
<h1><strong><em>Specifications</em></strong></h1>
<table>
<tbody>
<tr>
<td colspan="2" width="185">model code</td>
<td colspan="2" width="247">MVW1F -02</td>
<td width="248">MVW1RF -02</td>
</tr>
<tr>
<td colspan="2" width="185">Port size</td>
<td colspan="3" width="495">Rc 1/8・Rc 1/4・Rc 3/8</td>
</tr>
<tr>
<td colspan="2" width="185">Effective sectional area</td>
<td colspan="3" width="495">3.0 ㎜2</td>
</tr>
<tr>
<td colspan="2" width="185">Operating pressure</td>
<td colspan="3" width="495">0 ～ 0.8MPa</td>
</tr>
<tr>
<td colspan="2" width="185">Proof pressure</td>
<td colspan="3" width="495">1.2MPa</td>
</tr>
<tr>
<td colspan="2" width="185">Fluid temperature</td>
<td width="149">— 20 ～ 50℃</td>
<td colspan="2" rowspan="2" width="346">Remove moisture perfectly from the fluid to      <u>                                                                                     </u></p>
<p>prevent freezing when used at 5℃ or lower.</td>
</tr>
<tr>
<td colspan="2" width="185">Ambient temperature</td>
<td width="149">— 20 ～ 50℃</td>
</tr>
<tr>
<td rowspan="5" width="23">Solenoid</td>
<td width="162">Rated voltage</td>
<td colspan="3" width="495">See model code section.</td>
</tr>
<tr>
<td width="162">Allowable votage fluctuation</td>
<td colspan="3" width="495">± 10% of applicable voltage</td>
</tr>
<tr>
<td width="162">Temperature rise</td>
<td colspan="3" width="495">Max. 80℃</td>
</tr>
<tr>
<td width="162">Insulation class</td>
<td colspan="3" width="495">JIS C 4003 Class B</td>
</tr>
<tr>
<td width="162">Power consumption</td>
<td colspan="2" width="247">AC……10VA</td>
<td width="248">DC……6W</td>
</tr>
<tr>
<td colspan="2" width="185">Response time</td>
<td colspan="2" width="247">AC……Less than 0.02s</td>
<td width="248">DC……Less than 0.03s</td>
</tr>
<tr>
<td colspan="2" width="185">Performanse frequency</td>
<td colspan="2" width="247">Max. 4 cycle/s</td>
<td width="248">Min. 1 cycle/6 mon.</td>
</tr>
<tr>
<td colspan="2" width="185">Mass</td>
<td colspan="3" width="495">0.4㎏</td>
</tr>
</tbody>
</table>
<h1>External  Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-24696 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-12.png" alt="MVW1F-02" width="1350" height="714" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-12.png 1350w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-12-300x159.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-12-1024x542.png 1024w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-12-768x406.png 768w" sizes="auto, (max-width: 1350px) 100vw, 1350px" /></p>
<h1>DIN connector（Option）Installation</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-24697" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-11.png" alt="" width="639" height="437" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-11.png 639w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-11-300x205.png 300w" sizes="auto, (max-width: 639px) 100vw, 639px" /></p>
<h1>Conduit connector（Option）Installation</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-24698" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-7.png" alt="" width="658" height="431" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-7.png 658w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-7-300x197.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-7-180x118.png 180w" sizes="auto, (max-width: 658px) 100vw, 658px" /></p>
<h1>Actuation</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-24699 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/4.png" alt="MVW1F-02" width="1213" height="381" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/4.png 1213w, https://koueitrading.com/global/wp-content/uploads/2021/02/4-300x94.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/4-1024x322.png 1024w, https://koueitrading.com/global/wp-content/uploads/2021/02/4-768x241.png 768w" sizes="auto, (max-width: 1213px) 100vw, 1213px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-magster-%e2%85%b1f-mvw1f-02-3-port-solenoid-valves-gasket-connected-type-normally-closed/">KONAN MAGSTER ⅡF MVW1F-02 3 Port Solenoid Valves Gasket-connected type Normally Closed</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN MAGSTER ⅡF AVPC1-08 5 Port Air Operated Valves Gasket-connected 3 Positions Closed Center Type</title>
		<link>https://koueitrading.com/global/product/konan-magster-%e2%85%b1f-avpc1-08-5-port-air-operated-valves-gasket-connected-3-positions-closed-center-type/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Wed, 10 Mar 2021 02:17:39 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25005</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN Model: AVPC1-08 Model Code Specification External Dimensions Kouei is Distributor/Agent of KONAN. Other items of KONAN. Request the quotation for KONAN. &#160;</p>
The post <a href="https://koueitrading.com/global/product/konan-magster-%e2%85%b1f-avpc1-08-5-port-air-operated-valves-gasket-connected-3-positions-closed-center-type/">KONAN MAGSTER ⅡF AVPC1-08 5 Port Air Operated Valves Gasket-connected 3 Positions Closed Center Type</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN<br />
Model: AVPC1-08</p>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-24983 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-52.png" alt="AVPC1-08" width="1262" height="738" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-52.png 1262w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-52-300x175.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-52-1024x599.png 1024w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-52-768x449.png 768w" sizes="auto, (max-width: 1262px) 100vw, 1262px" /></p>
<h1>Specification</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-24984 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-20.png" alt="AVPC1-08" width="1232" height="341" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-20.png 1232w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-20-300x83.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-20-1024x283.png 1024w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-20-768x213.png 768w" sizes="auto, (max-width: 1232px) 100vw, 1232px" /></p>
<h1>External Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25006 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/1-7.png" alt="AVPC1-08" width="950" height="655" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/1-7.png 950w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-7-300x207.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-7-768x530.png 768w" sizes="auto, (max-width: 950px) 100vw, 950px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-magster-%e2%85%b1f-avpc1-08-5-port-air-operated-valves-gasket-connected-3-positions-closed-center-type/">KONAN MAGSTER ⅡF AVPC1-08 5 Port Air Operated Valves Gasket-connected 3 Positions Closed Center Type</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN NB/NC201 2-port Solenoid Valves For Nuclear Power Plants Normally Closed</title>
		<link>https://koueitrading.com/global/product/konan-nb-nc201-2-port-solenoid-valves-for-nuclear-power-plants-normally-closed/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Wed, 10 Mar 2021 01:30:27 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=26282</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN Model: NB/NC201 N20 series 2-port solenoid valves for nuclear power plants are pilot type valves incorporating hanging diaphragm that enables operation at zero differential pressure. Applicable pressure ranges from -100 KPa to 1.37MPa,and brass or stainless steel body can be selected for NC application for control of various fluids. [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-nb-nc201-2-port-solenoid-valves-for-nuclear-power-plants-normally-closed/">KONAN NB/NC201 2-port Solenoid Valves For Nuclear Power Plants Normally Closed</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN<br />
Model: NB/NC201</p>
<p>N20 series 2-port solenoid valves for nuclear power plants are pilot type valves incorporating hanging diaphragm that enables operation at zero differential pressure.<br />
Applicable pressure ranges from -100 KPa to 1.37MPa,and brass or stainless steel body can be selected for NC application for control of various fluids.</p>
<p>■Applicable fluid：Air / Inert gas<br />
■Valve type : NB/NC201（Normally closed type）　NB/NC202（Normally open type）<br />
■Operation type : Pilot (operates with no differential pressure)<br />
■Port size：Rc3/8 , Rc1/2 , Rc3/4</p>
<h1>Specification</h1>
<table>
<tbody>
<tr>
<th colspan="4">Model code</th>
<td colspan="3">NB/NC201</td>
<td colspan="3">NB/NC202</td>
</tr>
<tr>
<th colspan="4">Valve operation type</th>
<td colspan="3">Normally closed</td>
<td colspan="3">Normally open</td>
</tr>
<tr>
<th colspan="4">Port size</th>
<td>Rc3/8</td>
<td>Rc1/2</td>
<td>Rc3/4</td>
<td>Rc3/8</td>
<td>Rc1/2</td>
<td>Rc3/4</td>
</tr>
<tr>
<th colspan="4">Orifice size（mm）</th>
<td colspan="2">15.9</td>
<td>19.1</td>
<td colspan="2">15.9</td>
<td>19.1</td>
</tr>
<tr>
<th colspan="4">Cv value</th>
<td>3.3</td>
<td>4.1</td>
<td>5.5</td>
<td>3.3</td>
<td>4.1</td>
<td>5.5</td>
</tr>
<tr>
<th rowspan="3">Operating<br />
pressure<br />
differential<br />
（MPa）</th>
<th colspan="3">Min.</th>
<td colspan="6">0</td>
</tr>
<tr>
<th rowspan="2">Max.</th>
<th rowspan="2">Air/Inert gas</th>
<th>AC</th>
<td colspan="3">0.96</td>
<td colspan="3">1.37</td>
</tr>
<tr>
<th>DC</th>
<td colspan="3">0.61</td>
<td colspan="3">0.86</td>
</tr>
<tr>
<th colspan="4">Body</th>
<td colspan="6">Brass , stainless steel</td>
</tr>
<tr>
<th colspan="4">Elastomer</th>
<td colspan="6">Nitrile rubber（only NC）,Fluorine rubber（only NB）,Ethylene propylene（only NB）</td>
</tr>
<tr>
<th colspan="4">Housing</th>
<td colspan="6">NEMA4 drip-proof</td>
</tr>
<tr>
<th rowspan="6">Solenoid</th>
<th colspan="2" rowspan="2">Applicable voltage</th>
<th>AC</th>
<td colspan="6">100V , 110V , 115V , 120V</td>
</tr>
<tr>
<th>DC</th>
<td colspan="6">100V , 110V , 125V</td>
</tr>
<tr>
<th colspan="3">Allowable voltage fluctuation</th>
<td colspan="6">-15% to 10% of applicable voltage</td>
</tr>
<tr>
<th colspan="3">Insulation class</th>
<td colspan="6">Class H</td>
</tr>
<tr>
<th colspan="3">Leadwire length（mm）</th>
<td colspan="6">600</td>
</tr>
<tr>
<th colspan="3">Ambient temperature</th>
<td colspan="6">Refer to catalog for details.</td>
</tr>
<tr>
<th colspan="4">Installation position</th>
<td colspan="6">As desired（Horizontal mounting with solenoid at upper side is recommended）</td>
</tr>
<tr>
<th colspan="4">Options</th>
<td colspan="6">Mounting bracket , NPT（port） , Terminal box , Manual operating system</td>
</tr>
</tbody>
</table>
<h1>External Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-26283" src="https://koueitrading.com/global/wp-content/uploads/2021/03/3.png" alt="" width="852" height="493" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/3.png 852w, https://koueitrading.com/global/wp-content/uploads/2021/03/3-300x174.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/03/3-768x444.png 768w" sizes="auto, (max-width: 852px) 100vw, 852px" /></p>
<h1>JIS Symbols</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-26284" src="https://koueitrading.com/global/wp-content/uploads/2021/03/1-1.png" alt="" width="328" height="135" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/1-1.png 328w, https://koueitrading.com/global/wp-content/uploads/2021/03/1-1-300x123.png 300w" sizes="auto, (max-width: 328px) 100vw, 328px" /></p>
<h1>Coil Data</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-26285" src="https://koueitrading.com/global/wp-content/uploads/2021/03/2-1.png" alt="" width="448" height="217" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/2-1.png 448w, https://koueitrading.com/global/wp-content/uploads/2021/03/2-1-300x145.png 300w" sizes="auto, (max-width: 448px) 100vw, 448px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-nb-nc201-2-port-solenoid-valves-for-nuclear-power-plants-normally-closed/">KONAN NB/NC201 2-port Solenoid Valves For Nuclear Power Plants Normally Closed</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN MAGSTER ⅡF MVPOF ー08 5 Port Solenoid Valves Gasket-connected Type 3 Positions Center Open To Exhaust</title>
		<link>https://koueitrading.com/global/product/konan-magster-%e2%85%b1f-mvpof-%e3%83%bc08-5-port-solenoid-valves-gasket-connected-type-3-positions-center-open-to-exhaust/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Wed, 10 Mar 2021 01:04:40 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=24743</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: MAGSTER ⅡF MVPOF -08 Model Code External  Dimensions Actuation Specifications &#160; Model code Return MVS2F-03 MVS2F-08 Hold MVD2F-03 MVD2F-08 Closed center MVPCF-03 MVPCF-08 Center open to exhaust MVPOF-03 MVPOF-08 Center open to pressure MVPEF-03 MVPEF-08 Port size Rc 1/4 Rc 3/8 Rc 1/2 Rc 3/4 Rc 1 [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-magster-%e2%85%b1f-mvpof-%e3%83%bc08-5-port-solenoid-valves-gasket-connected-type-3-positions-center-open-to-exhaust/">KONAN MAGSTER ⅡF MVPOF ー08 5 Port Solenoid Valves Gasket-connected Type 3 Positions Center Open To Exhaust</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: MAGSTER ⅡF MVPOF -08</p>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-24704" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-13.png" alt="" width="1330" height="809" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-13.png 1330w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-13-300x182.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-13-1024x623.png 1024w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-13-768x467.png 768w" sizes="auto, (max-width: 1330px) 100vw, 1330px" /></p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-24705" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-45.png" alt="" width="1323" height="148" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-45.png 1323w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-45-300x34.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-45-1024x115.png 1024w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-45-768x86.png 768w" sizes="auto, (max-width: 1323px) 100vw, 1323px" /></p>
<h1>External  Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-24737" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-17.png" alt="" width="1298" height="816" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-17.png 1298w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-17-300x189.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-17-1024x644.png 1024w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-17-768x483.png 768w" sizes="auto, (max-width: 1298px) 100vw, 1298px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-24738 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-49.png" alt="MAGSTER ⅡF" width="895" height="775" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-49.png 895w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-49-300x260.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-49-768x665.png 768w" sizes="auto, (max-width: 895px) 100vw, 895px" /></p>
<h1>Actuation</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-24739 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-9.png" alt="MAGSTER ⅡF" width="1335" height="735" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-9.png 1335w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-9-300x165.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-9-1024x564.png 1024w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-9-768x423.png 768w" sizes="auto, (max-width: 1335px) 100vw, 1335px" /></p>
<h1><strong><em>Specifications</em></strong></h1>
<table>
<tbody>
<tr>
<td colspan="2" rowspan="5" width="76">&nbsp;</p>
<p>Model code</td>
<td width="110">Return</td>
<td colspan="5" width="297">MVS2F-03</td>
<td colspan="2" width="198">MVS2F-08</td>
</tr>
<tr>
<td width="110">Hold</td>
<td colspan="5" width="297">MVD2F-03</td>
<td colspan="2" width="198">MVD2F-08</td>
</tr>
<tr>
<td width="110">Closed center</td>
<td colspan="5" width="297">MVPCF-03</td>
<td colspan="2" width="198">MVPCF-08</td>
</tr>
<tr>
<td width="110">Center open to exhaust</td>
<td colspan="5" width="297">MVPOF-03</td>
<td colspan="2" width="198">MVPOF-08</td>
</tr>
<tr>
<td width="110">Center open to pressure</td>
<td colspan="5" width="297">MVPEF-03</td>
<td colspan="2" width="198">MVPEF-08</td>
</tr>
<tr>
<td colspan="3" width="185">Port size</td>
<td colspan="2" width="99">Rc 1/4</td>
<td width="99">Rc 3/8</td>
<td colspan="2" width="99">Rc 1/2</td>
<td width="99">Rc 3/4</td>
<td width="99">Rc 1</td>
</tr>
<tr>
<td colspan="3" width="185">Effective sectional area</td>
<td colspan="2" width="99">40㎜2</td>
<td width="99">55㎜2</td>
<td colspan="2" width="99">70㎜2</td>
<td width="99">175㎜2</td>
<td width="99">185㎜2</td>
</tr>
<tr>
<td colspan="3" rowspan="2" width="185">&nbsp;</p>
<p>Operating pressure</td>
<td colspan="5" width="297">0 ～ 0.8MPa</td>
<td colspan="2" width="198">0.12 ～ 0.7MPa</td>
</tr>
<tr>
<td colspan="7" width="495">Case of external pilot type</p>
<p>Pilot operating pressure  ≧      Operating pressure</td>
</tr>
<tr>
<td colspan="3" width="185">Proof pressure</td>
<td colspan="5" width="297">1.2MPa</td>
<td colspan="2" width="198">1.05MPa</td>
</tr>
<tr>
<td colspan="3" width="185">Fluid temperature</td>
<td width="82">ー5～ 50℃</td>
<td colspan="3" rowspan="2" width="206">Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.</td>
<td width="10"></td>
<td colspan="2" width="198">— 20 ～ 50℃ Remove moisture perfectly from the fluid to</td>
</tr>
<tr>
<td colspan="3" width="185">Ambient temperature</td>
<td width="82">ー5～ 50℃</td>
<td width="10"></td>
<td colspan="2" width="198">— 20 ～ 50℃ prevent freezing when used at 5℃ or lower.</td>
</tr>
<tr>
<td rowspan="5" width="19">Solenoid</td>
<td colspan="2" width="166">Rated voltage</td>
<td colspan="7" width="495">See model code section.</td>
</tr>
<tr>
<td colspan="2" width="166">Allowable votage fluctuation</td>
<td colspan="7" width="495">± 10% of applicable voltage</td>
</tr>
<tr>
<td colspan="2" width="166">Temperature rise</td>
<td colspan="7" width="495">Max. 80℃（Resistance method）</td>
</tr>
<tr>
<td colspan="2" width="166">Insulation class</td>
<td colspan="7" width="495">JIS C 4003 Class B</td>
</tr>
<tr>
<td colspan="2" width="166">Power consumption</td>
<td colspan="7" width="495">AC……10VA             DC……6W</td>
</tr>
<tr>
<td colspan="3" width="185">Response time</td>
<td colspan="5" width="297">AC……Less than 0.03s     DC Less than 0.05s</td>
<td colspan="2" width="198">AC……Less than 0.07s DC Less than 0.05s</td>
</tr>
<tr>
<td colspan="3" width="185">Performance frequency</td>
<td colspan="7" width="495">Max. 4 cycle/s           Min. 1 cycle/6 mon.</td>
</tr>
<tr>
<td colspan="3" width="185">Mass</td>
<td colspan="5" width="297">Return……0.4 ㎏ Other……1.6 ㎏</td>
<td colspan="2" width="198">Return……4.5 ㎏ Other……5 ㎏</td>
</tr>
</tbody>
</table>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-magster-%e2%85%b1f-mvpof-%e3%83%bc08-5-port-solenoid-valves-gasket-connected-type-3-positions-center-open-to-exhaust/">KONAN MAGSTER ⅡF MVPOF ー08 5 Port Solenoid Valves Gasket-connected Type 3 Positions Center Open To Exhaust</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN MVPCF/EF/OF Series 5-Port Solenoid Valves Drip-proof Type</title>
		<link>https://koueitrading.com/global/product/konan-mvpcf-ef-of-series-5-port-solenoid-valves-drip-proof-type/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Wed, 10 Mar 2021 00:15:21 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25419</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: MVPCF/EF/OF Series Specifications Closed center Pressure center Exhaust center Closed center Pressure center Exhaust center Type   Explosion- proof type   Pressure-resistant packing MVPCF-03-E2K MVPCF-03-E2E MVPCF-03-E2Y MVPEF-03-E2K MVPEF-03-E2E MVPEF-03-E2Y MVPOF-03-E2K MVPOF-03-E2E MVPOF-03-E2Y MVPCN-08-E2K MVPCN-08-E2E MVPCN-08-E2Y MVPEN-08-E2K MVPEN-08-E2E MVPEN-08-E2Y MVPON-08-E2K MVPON-08-E2E MVPON-08-E2Y Conduit tube MVPCF-03-E1K MVPCF-03-E1E MVPEF-03-E1K MVPEF-03-E1E [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-mvpcf-ef-of-series-5-port-solenoid-valves-drip-proof-type/">KONAN MVPCF/EF/OF Series 5-Port Solenoid Valves Drip-proof Type</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: MVPCF/EF/OF Series</p>
<h1>Specifications</h1>
<table>
<tbody>
<tr>
<td colspan="3" width="193"></td>
<td width="82">Closed center</td>
<td width="82">Pressure center</td>
<td width="82">Exhaust center</td>
<td width="82">Closed center</td>
<td width="82">Pressure center</td>
<td width="82">Exhaust center</td>
</tr>
<tr>
<td rowspan="3" width="26">Type</td>
<td rowspan="2" width="53"><strong> </strong></p>
<p>Explosion- proof type</td>
<td width="113"><strong> </strong></p>
<p>Pressure-resistant packing</td>
<td width="82">MVPCF-03-E2K MVPCF-03-E2E MVPCF-03-E2Y</td>
<td width="82">MVPEF-03-E2K MVPEF-03-E2E MVPEF-03-E2Y</td>
<td width="82">MVPOF-03-E2K MVPOF-03-E2E MVPOF-03-E2Y</td>
<td width="82">MVPCN-08-E2K MVPCN-08-E2E MVPCN-08-E2Y</td>
<td width="82">MVPEN-08-E2K MVPEN-08-E2E MVPEN-08-E2Y</td>
<td width="82">MVPON-08-E2K MVPON-08-E2E MVPON-08-E2Y</td>
</tr>
<tr>
<td width="113">Conduit tube</td>
<td width="82">MVPCF-03-E1K MVPCF-03-E1E</td>
<td width="82">MVPEF-03-E1K MVPEF-03-E1E</td>
<td width="82">MVPOF-03-E1K MVPOF-03-E1E</td>
<td width="82">MVPCN-08-E1K MVPCN-08-E1E</td>
<td width="82">MVPEN-08-E1K MVPEN-08-E1E</td>
<td width="82">MVPON-08-E1K MVPON-08-E1E</td>
</tr>
<tr>
<td colspan="2" width="166">Drip-proof type</td>
<td width="82">MVPCF-03-E3K</td>
<td width="82">MVPEF-03-E3K</td>
<td width="82">MVPOF-03-E3K</td>
<td width="82">MVPCN-08-E3K</td>
<td width="82">MVPEN-08-E3K</td>
<td width="82">MVPON-08-E3K</td>
</tr>
<tr>
<td colspan="3" width="193">Port size（Rc）</td>
<td colspan="3" width="245">1/4・3/8・1/2</td>
<td colspan="3" width="245">3/4・1</td>
</tr>
<tr>
<td colspan="3" width="193">Effective sectional area（CV value）</td>
<td colspan="3" width="245">40㎟（2.2）・55㎟（3.0）・70㎟（3.8）</td>
<td colspan="3" width="245">175㎟（9.5）・185㎟（10.0）</td>
</tr>
<tr>
<td colspan="3" rowspan="2" width="193"><strong> </strong></p>
<p>Operating pressure</td>
<td colspan="3" width="245">0.2 〜 0.7MPa</td>
<td colspan="3" width="245">0.12 〜 0.7MPa</td>
</tr>
<tr>
<td colspan="6" width="489">In case of separate pilot supply type  Pilot operating pressure ≧ Operating pressure</td>
</tr>
<tr>
<td colspan="3" width="193">Pressure resistance</td>
<td colspan="6" width="489">1.05MPa</td>
</tr>
<tr>
<td colspan="3" width="193">Operating temperature</td>
<td colspan="3" width="245">－5〜 60℃</td>
<td colspan="3" width="245">— 20 〜 50℃</td>
</tr>
<tr>
<td colspan="3" width="193">Operating frequency</td>
<td colspan="6" width="489">1 cycle / s max.       /      1 cycle / 6 months min.</td>
</tr>
<tr>
<td colspan="3" width="193">Operation（response）time</td>
<td colspan="3" width="245">0.1 s max.</td>
<td colspan="3" width="245">0.5 s max.</td>
</tr>
<tr>
<td rowspan="7" width="26">Solenoid</td>
<td colspan="2" width="166">Rated voltage</td>
<td colspan="6" width="489">Refer to Model Code</td>
</tr>
<tr>
<td colspan="2" width="166">Voltage fluctuation tolerance</td>
<td colspan="6" width="489">— 15％〜 10％ of rated voltage</td>
</tr>
<tr>
<td colspan="2" width="166">Temperature rise</td>
<td colspan="6" width="489">80 deg max.</td>
</tr>
<tr>
<td colspan="2" width="166">Insulation class</td>
<td colspan="6" width="489">Class H</td>
</tr>
<tr>
<td colspan="2" width="166">Insulation resistance</td>
<td colspan="6" width="489">10MΩ min.</td>
</tr>
<tr>
<td colspan="2" width="166">Rated current</td>
<td colspan="6" width="489">Refer to Rated current data on page A-39</td>
</tr>
<tr>
<td colspan="2" width="166">Explosion-proof standard</td>
<td colspan="6" width="489">Flame-proof enclosure construction d2G4 / Exd Ⅱ BT4</td>
</tr>
<tr>
<td colspan="3" width="193">Mass</td>
<td colspan="3" width="245">Approx. 3.5kg</td>
<td colspan="3" width="245">Approx. 5.5kg</td>
</tr>
</tbody>
</table>
<h1><img loading="lazy" decoding="async" class="alignnone size-full wp-image-25410" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-75.png" alt="" width="731" height="179" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-75.png 731w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-75-300x73.png 300w" sizes="auto, (max-width: 731px) 100vw, 731px" /></h1>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-25411" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-42.png" alt="" width="928" height="383" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-42.png 928w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-42-300x124.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-42-768x317.png 768w" sizes="auto, (max-width: 928px) 100vw, 928px" /> <img loading="lazy" decoding="async" class="alignnone size-full wp-image-25412" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-36.png" alt="" width="916" height="608" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-36.png 916w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-36-300x199.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-36-768x510.png 768w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-36-180x118.png 180w" sizes="auto, (max-width: 916px) 100vw, 916px" /> <img loading="lazy" decoding="async" class="alignnone size-full wp-image-25413" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-20.png" alt="" width="911" height="241" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-20.png 911w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-20-300x79.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-20-768x203.png 768w" sizes="auto, (max-width: 911px) 100vw, 911px" /></p>
<h1>Outside Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25422 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/1-39.png" alt="MVPCF/EF/OF Series" width="450" height="416" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/1-39.png 450w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-39-300x277.png 300w" sizes="auto, (max-width: 450px) 100vw, 450px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-mvpcf-ef-of-series-5-port-solenoid-valves-drip-proof-type/">KONAN MVPCF/EF/OF Series 5-Port Solenoid Valves Drip-proof Type</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN NB/NC301 2-port Solenoid Valves For Nuclear Power Plants Normally Closed</title>
		<link>https://koueitrading.com/global/product/konan-nb-nc301-2-port-solenoid-valves-for-nuclear-power-plants-normally-closed/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Tue, 09 Mar 2021 23:39:33 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=26274</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: NB/NC301 N30 series 2-port solenoid valves for nuclear power plants are small size direct-acting valves incorporating soft seal.The space-saving compact valves are provided with brass or stainless steel body for control of various fluids in NB/NC applications. Specification Model code NB/NC301 NC302 Valve operation type Normally closed [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-nb-nc301-2-port-solenoid-valves-for-nuclear-power-plants-normally-closed/">KONAN NB/NC301 2-port Solenoid Valves For Nuclear Power Plants Normally Closed</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: NB/NC301</p>
<p>N30 series 2-port solenoid valves for nuclear power plants are small size direct-acting valves incorporating soft seal.The space-saving compact valves<br />
are provided with brass or stainless steel body for control of various fluids in NB/NC applications.</p>
<h1>Specification</h1>
<table>
<tbody>
<tr>
<th colspan="4">Model code</th>
<td colspan="6">NB/NC301</td>
<td colspan="2">NC302</td>
</tr>
<tr>
<th colspan="4">Valve operation type</th>
<td colspan="6">Normally closed</td>
<td colspan="2">Normally open</td>
</tr>
<tr>
<th colspan="4">Port size</th>
<td colspan="6">Rc1/4</td>
<td colspan="2">Rc1/4</td>
</tr>
<tr>
<th colspan="4">Orifice size（mm）</th>
<td>1.2</td>
<td>1.6</td>
<td>2.4</td>
<td>3.2</td>
<td>4.0</td>
<td>4.8</td>
<td>2.4</td>
<td>3.2</td>
</tr>
<tr>
<th colspan="4">Cv value</th>
<td>0.05</td>
<td>0.1</td>
<td>0.21</td>
<td>0.36</td>
<td>0.44</td>
<td>0.65</td>
<td>0.21</td>
<td>0.36</td>
</tr>
<tr>
<th rowspan="3">Operating<br />
pressure<br />
differential<br />
（MPa）</th>
<th colspan="3">Min.</th>
<td colspan="6">0</td>
<td colspan="2">0</td>
</tr>
<tr>
<th rowspan="2">Max.</th>
<th rowspan="2">Air/Inert gas</th>
<th>AC</th>
<td>7.20</td>
<td>4.80</td>
<td>2.74</td>
<td>1.37</td>
<td>1.02</td>
<td>0.68</td>
<td>1.02</td>
<td>0.68</td>
</tr>
<tr>
<th>DC</th>
<td>6.86</td>
<td>2.05</td>
<td>1.37</td>
<td>0.96</td>
<td>0.68</td>
<td>0.48</td>
<td>1.02</td>
<td>0.68</td>
</tr>
<tr>
<th colspan="4">Body</th>
<td colspan="8">Brass , stainless steel</td>
</tr>
<tr>
<th colspan="4">Elastomer</th>
<td colspan="8">Nitrile rubber（only NC）,Fluorine rubber（only NB）,Ethylene propylene（only NB）</td>
</tr>
<tr>
<th colspan="4">Housing</th>
<td colspan="8">NEMA4 drip-proof</td>
</tr>
<tr>
<th rowspan="6">Solenoid</th>
<th colspan="2" rowspan="2">Applicable voltage</th>
<th>AC</th>
<td colspan="8">100V , 110V , 115V , 120V</td>
</tr>
<tr>
<th>DC</th>
<td colspan="8">100V , 110V , 125V</td>
</tr>
<tr>
<th colspan="3">Allowable voltage fluctuation</th>
<td colspan="8">-15% to 10% of applicable voltage</td>
</tr>
<tr>
<th colspan="3">Insulation class</th>
<td colspan="8">Class H</td>
</tr>
<tr>
<th colspan="3">Leadwire length（mm）</th>
<td colspan="8">600</td>
</tr>
<tr>
<th colspan="3">Ambient temperature</th>
<td colspan="8">Refer to catalog for details.</td>
</tr>
<tr>
<th colspan="4">Installation position</th>
<td colspan="8">As desired（Horizontal mounting with solenoid at upper side is recommended）</td>
</tr>
<tr>
<th colspan="4">Options</th>
<td colspan="8">Terminal box , NPT（port）</td>
</tr>
</tbody>
</table>
<h1>JIS Symbols</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-26275 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/03/Capture.png" alt="NB/NC301" width="339" height="137" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/Capture.png 339w, https://koueitrading.com/global/wp-content/uploads/2021/03/Capture-300x121.png 300w" sizes="auto, (max-width: 339px) 100vw, 339px" /></p>
<h1>Coil Data</h1>
<table>
<tbody>
<tr>
<td rowspan="2" width="87">Model code</td>
<td rowspan="2" width="77">Frequency (Hz)</td>
<td colspan="2" width="139">Apparent power (VA)</td>
<td colspan="2" width="188">Power consumption (W)</td>
</tr>
<tr>
<td width="67">Issuance</td>
<td width="73">Retention</td>
<td width="92">AC</td>
<td width="96">DC</td>
</tr>
<tr>
<td rowspan="2" width="87">N301</td>
<td width="77">50</td>
<td width="67">37</td>
<td width="73">18</td>
<td rowspan="2" width="92">10</td>
<td rowspan="4" width="96">10</td>
</tr>
<tr>
<td width="77">60</td>
<td width="67">30</td>
<td width="73">13</td>
</tr>
<tr>
<td rowspan="2" width="87">N302</td>
<td width="77">50</td>
<td width="67">43</td>
<td width="73">23</td>
<td rowspan="2" width="92">11</td>
</tr>
<tr>
<td width="77">60</td>
<td width="67">37</td>
<td width="73">16</td>
</tr>
</tbody>
</table>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-nb-nc301-2-port-solenoid-valves-for-nuclear-power-plants-normally-closed/">KONAN NB/NC301 2-port Solenoid Valves For Nuclear Power Plants Normally Closed</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN 453S Series 5-Port Solenoid Valves Conduit Tube Return Type</title>
		<link>https://koueitrading.com/global/product/konan-453s-series-5-port-solenoid-valves-conduit-tube-return-type/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Tue, 09 Mar 2021 11:11:03 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25365</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: 453S Series Outside Dimensions Model Code Specifications Return Hold Return Hold Type   Explosion- proof type   Pressure-resistant packing 453S202K-E2K 453S202K-E2E 453S202K-E2Y 453S203K-E2K 453S203K-E2E 453S203K-E2Y 453D202K-E2K 453D202K-E2E 453D203K-E2K 453D203K-E2E 453S403C-E2K 453S403C-E2E 453S403C-E2Y 453S404C-E2K 453S404C-E2E 453S404C-E2Y 453D403C-E2K 453D403C-E2E 453D404C-E2K 453D404C-E2E Conduit tube 453S202K-E1K 453S202K-E1E 453S203K-E1K 453S203K-E1E 453D202K-E1K 453D202K-E1E [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-453s-series-5-port-solenoid-valves-conduit-tube-return-type/">KONAN 453S Series 5-Port Solenoid Valves Conduit Tube Return Type</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: 453S Series</p>
<h1>Outside Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-25366" src="https://koueitrading.com/global/wp-content/uploads/2021/02/2-16.png" alt="" width="449" height="597" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/2-16.png 449w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-16-226x300.png 226w" sizes="auto, (max-width: 449px) 100vw, 449px" /> <img loading="lazy" decoding="async" class="alignnone size-full wp-image-25367" src="https://koueitrading.com/global/wp-content/uploads/2021/02/1-26.png" alt="" width="461" height="590" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/1-26.png 461w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-26-234x300.png 234w" sizes="auto, (max-width: 461px) 100vw, 461px" /></p>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-25356" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-34.png" alt="" width="914" height="826" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-34.png 914w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-34-300x271.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-34-768x694.png 768w" sizes="auto, (max-width: 914px) 100vw, 914px" /></p>
<h1>Specifications</h1>
<table>
<tbody>
<tr>
<td colspan="3" width="193"></td>
<td colspan="2" width="123">Return</td>
<td colspan="2" width="123">Hold</td>
<td colspan="2" width="123">Return</td>
<td colspan="2" width="123">Hold</td>
</tr>
<tr>
<td rowspan="3" width="26">Type</td>
<td rowspan="2" width="53"><strong> </strong></p>
<p>Explosion- proof type</td>
<td width="113"><strong> </strong></p>
<p>Pressure-resistant packing</td>
<td width="61">453S202K-E2K</p>
<p>453S202K-E2E</p>
<p>453S202K-E2Y</td>
<td width="61">453S203K-E2K</p>
<p>453S203K-E2E</p>
<p>453S203K-E2Y</td>
<td width="61">453D202K-E2K</p>
<p>453D202K-E2E</td>
<td width="61">453D203K-E2K</p>
<p>453D203K-E2E</td>
<td width="61">453S403C-E2K</p>
<p>453S403C-E2E</p>
<p>453S403C-E2Y</td>
<td width="61">453S404C-E2K</p>
<p>453S404C-E2E</p>
<p>453S404C-E2Y</td>
<td width="61">453D403C-E2K</p>
<p>453D403C-E2E</td>
<td width="61">453D404C-E2K</p>
<p>453D404C-E2E</td>
</tr>
<tr>
<td width="113">Conduit tube</td>
<td width="61">453S202K-E1K</p>
<p>453S202K-E1E</td>
<td width="61">453S203K-E1K</p>
<p>453S203K-E1E</td>
<td width="61">453D202K-E1K</p>
<p>453D202K-E1E</td>
<td width="61">453D203K-E1K</p>
<p>453D203K-E1E</td>
<td width="61">453S403C-E1K</p>
<p>453S403C-E1E</td>
<td width="61">453S404C-E1K</p>
<p>453S404C-E1E</td>
<td width="61">453D403C-E1K</p>
<p>453D403C-E1E</td>
<td width="61">453D404C-E1K</p>
<p>453D404C-E1E</td>
</tr>
<tr>
<td colspan="2" width="166">Drip-proof type</td>
<td width="61">453S202K-E3K</td>
<td width="61">453S203K-E3K</td>
<td width="61">453D202K-E3K</td>
<td width="61">453D203K-E3K</td>
<td width="61">453S403C-E3K</td>
<td width="61">453S404C-E3K</td>
<td width="61">453D403C-E3K</td>
<td width="61">453D404C-E3K</td>
</tr>
<tr>
<td colspan="3" width="193">Port size（Rc）</td>
<td width="61">1/4</td>
<td width="61">3/8</td>
<td width="61">1/4</td>
<td width="61">3/8</td>
<td width="61">3/8</td>
<td width="61">1/2</td>
<td width="61">3/8</td>
<td width="61">1/2</td>
</tr>
<tr>
<td colspan="3" width="193">Effective sectional area（CV value）</td>
<td colspan="4" width="246">22㎟（1.2）</td>
<td colspan="4" width="246">40㎟（2.2）</td>
</tr>
<tr>
<td colspan="3" width="193">Operating pressure</td>
<td colspan="8" width="491">0.2 〜 0.7MPa</td>
</tr>
<tr>
<td colspan="3" width="193">Pressure resistance</td>
<td colspan="8" width="491">1.05MPa</td>
</tr>
<tr>
<td colspan="3" width="193">Operating temperature</td>
<td colspan="8" width="491">－5〜 50℃</td>
</tr>
<tr>
<td colspan="3" width="193">Operating frequency</td>
<td colspan="8" width="491">1 cycle / s max.       /      1 cycle / 6 months min.</td>
</tr>
<tr>
<td colspan="3" width="193">Operation（response）time</td>
<td colspan="8" width="491">0.05 s max.</td>
</tr>
<tr>
<td rowspan="7" width="26">Solenoid</td>
<td colspan="2" width="166">Rated voltage</td>
<td colspan="8" width="491">Refer to Model Code</td>
</tr>
<tr>
<td colspan="2" width="166">Voltage fluctuation tolerance</td>
<td colspan="8" width="491">— 15％〜 10％ of rated voltage</td>
</tr>
<tr>
<td colspan="2" width="166">Temperature rise</td>
<td colspan="2" width="123">80 deg max.</td>
<td colspan="2" width="123">65 deg max.</td>
<td colspan="2" width="123">80 deg max.</td>
<td colspan="2" width="123">65 deg max..</td>
</tr>
<tr>
<td colspan="2" width="166">Insulation class</td>
<td colspan="8" width="491">Class H</td>
</tr>
<tr>
<td colspan="2" width="166">Insulation resistance</td>
<td colspan="8" width="491">10MΩ min.</td>
</tr>
<tr>
<td colspan="2" width="166">Rated current</td>
<td colspan="8" width="491">Refer to Rated current data on page A-39</td>
</tr>
<tr>
<td colspan="2" width="166">Explosion-proof standard</td>
<td colspan="8" width="491">Flame-proof enclosure construction d2G4 / Exd Ⅱ BT4</td>
</tr>
<tr>
<td colspan="3" width="193">Mass</td>
<td colspan="2" width="123">Approx. 1.7kg</td>
<td colspan="2" width="123">Approx. 1.8kg</td>
<td colspan="2" width="123">Approx. 2.0kg</td>
<td colspan="2" width="123">Approx. 2.1kg</td>
</tr>
</tbody>
</table>
<h1><img loading="lazy" decoding="async" class="alignnone size-full wp-image-25355" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-73.png" alt="" width="885" height="174" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-73.png 885w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-73-300x59.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-73-768x151.png 768w" sizes="auto, (max-width: 885px) 100vw, 885px" /></h1>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-453s-series-5-port-solenoid-valves-conduit-tube-return-type/">KONAN 453S Series 5-Port Solenoid Valves Conduit Tube Return Type</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN NA321 NA322 3-port Solenoid Valves For Nuclear Power Plants Normally Open</title>
		<link>https://koueitrading.com/global/product/konan-na322-3-port-solenoid-valves-for-nuclear-power-plants-normally-open/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Tue, 09 Mar 2021 08:01:27 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=26349</guid>

					<description><![CDATA[<p>Manufacturer: KONAN ELECTRIC Model: NA321 NA322 Product: 3-port Solenoid Valves For Nuclear Power Plants Normally Open NA321 NA322 series pilot-operated piston style 3-port solenoid valves show distinguished performance in high flow rate applications. The valves have large orifice. The valves have high reliability as quick exhaust valve. Specification Model code NA321 NA322 Valve operation type [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-na322-3-port-solenoid-valves-for-nuclear-power-plants-normally-open/">KONAN NA321 NA322 3-port Solenoid Valves For Nuclear Power Plants Normally Open</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Manufacturer: KONAN ELECTRIC<br />
Model: NA321 NA322<br />
Product: 3-port Solenoid Valves For Nuclear Power Plants Normally Open</p>
<p>NA321 NA322 series pilot-operated piston style 3-port solenoid valves show distinguished performance in high flow rate applications.<br />
The valves have large orifice. The valves have high reliability as quick exhaust valve.</p>
<h1>Specification</h1>
<table>
<tbody>
<tr>
<th colspan="4">Model code</th>
<td colspan="2">NA321</td>
<td colspan="2">NA322</td>
</tr>
<tr>
<th colspan="4">Valve operation type</th>
<td colspan="2">Normally closed</td>
<td colspan="2">Normally open</td>
</tr>
<tr>
<th colspan="4">Port size</th>
<td>Rc1/4</td>
<td>Rc3/8</td>
<td>Rc1/4</td>
<td>Rc3/8</td>
</tr>
<tr>
<th colspan="4">Orifice size（mm）</th>
<td colspan="4">Pressure side:7.1 Exhaust side:8.7</td>
</tr>
<tr>
<th colspan="4">Cv value</th>
<td colspan="4">Pressure side:0.8 Exhaust side:1.2</td>
</tr>
<tr>
<th rowspan="3">Operating<br />
pressure<br />
differential<br />
（MPa）</th>
<th colspan="3">Min.</th>
<td colspan="4">0.07</td>
</tr>
<tr>
<th rowspan="2">Max.</th>
<th rowspan="2">Air/Inert gas</th>
<th>AC</th>
<td colspan="4">0.85</td>
</tr>
<tr>
<th>DC</th>
<td colspan="4">0.85</td>
</tr>
<tr>
<th colspan="4">Body</th>
<td colspan="4">Brass</td>
</tr>
<tr>
<th colspan="4">Seal / seat</th>
<td colspan="4">Nitrile rubber（only NC）,Fluorine rubber（only NA,NB）</td>
</tr>
<tr>
<th colspan="4">Poppet</th>
<td colspan="4">Polyacetal（only NC）,Stainless steel（only NA,NB）</td>
</tr>
<tr>
<th colspan="4">Cartridge</th>
<td colspan="4">Brass</td>
</tr>
<tr>
<th colspan="4">Housing</th>
<td colspan="4">NEMA4 drip-proof</td>
</tr>
<tr>
<th rowspan="6">Solenoid</th>
<th colspan="2" rowspan="2">Applicable voltage</th>
<th>AC</th>
<td colspan="4">100V , 110V , 115V , 120V</td>
</tr>
<tr>
<th>DC</th>
<td colspan="4">100V , 110V , 125V</td>
</tr>
<tr>
<th colspan="3">Allowable voltage fluctuation</th>
<td colspan="4">-15% to 10% of applicable voltage</td>
</tr>
<tr>
<th colspan="3">Insulation class</th>
<td colspan="4">Class H</td>
</tr>
<tr>
<th colspan="3">Leadwire length（mm）</th>
<td colspan="4">600</td>
</tr>
<tr>
<th colspan="3">Ambient temperature</th>
<td colspan="4">Refer to catalog for details.</td>
</tr>
<tr>
<th colspan="4">Installation position</th>
<td colspan="4">As desired（Horizontal mounting with solenoid at upper side is recommended）</td>
</tr>
<tr>
<th colspan="4">Options</th>
<td colspan="4">Terminal box , NPT（port）</td>
</tr>
</tbody>
</table>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-na322-3-port-solenoid-valves-for-nuclear-power-plants-normally-open/">KONAN NA321 NA322 3-port Solenoid Valves For Nuclear Power Plants Normally Open</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN NA/NB/NC204 3-port Solenoid Valves For Nuclear Power Plants Normally Open</title>
		<link>https://koueitrading.com/global/product/konan-na-nb-nc204-3-port-solenoid-valves-for-nuclear-power-plants-normally-open/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Tue, 09 Mar 2021 07:56:48 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=26345</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: NA/NB/NC204 N203/204 series 3-port solenoid valves for nuclear power plants are pilot-type valves incorporating a diaphragm. With a high flow rate structure and operation at low differential pressure, the valves ensure excellent control reliability. Specification Model code NA/NB/NC203 NA/NB/NC204 Valve operation type Normally closed Normally open Port [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-na-nb-nc204-3-port-solenoid-valves-for-nuclear-power-plants-normally-open/">KONAN NA/NB/NC204 3-port Solenoid Valves For Nuclear Power Plants Normally Open</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: NA/NB/NC204</p>
<p><em><strong>N203/204 series 3-port solenoid valves for nuclear power plants are pilot-type valves incorporating a diaphragm.</strong></em><br />
<em><strong>With a high flow rate structure and operation at low differential pressure, the valves ensure excellent control reliability.</strong></em></p>
<h1>Specification</h1>
<table>
<tbody>
<tr>
<th colspan="4">Model code</th>
<td colspan="2">NA/NB/NC203</td>
<td colspan="2">NA/NB/NC204</td>
</tr>
<tr>
<th colspan="4">Valve operation type</th>
<td colspan="2">Normally closed</td>
<td colspan="2">Normally open</td>
</tr>
<tr>
<th colspan="4">Port size</th>
<td>Rc3/8</td>
<td>Rc1/2</td>
<td>Rc3/8</td>
<td>Rc1/2</td>
</tr>
<tr>
<th colspan="4">Orifice size（mm）</th>
<td colspan="2">15.9</td>
<td colspan="2">15.9</td>
</tr>
<tr>
<th colspan="4">Cv value</th>
<td>3.3</td>
<td>4.4</td>
<td>3.3</td>
<td>4.4</td>
</tr>
<tr>
<th rowspan="3">Operating<br />
pressure<br />
differential<br />
（MPa）</th>
<th colspan="3">Min.</th>
<td colspan="4">0.05</td>
</tr>
<tr>
<th rowspan="2">Max.</th>
<th rowspan="2">Air/Inert gas</th>
<th>AC</th>
<td colspan="4">1.02</td>
</tr>
<tr>
<th>DC</th>
<td colspan="4">1.02</td>
</tr>
<tr>
<th colspan="4">Body</th>
<td colspan="4">Brass</td>
</tr>
<tr>
<th colspan="4">Seal / seat</th>
<td colspan="4">Nitrile rubber（only NC）,Fluorine rubber（only NA,NB）,Ethylene propylene（only NA,NB）</td>
</tr>
<tr>
<th colspan="4">Poppet</th>
<td colspan="4">Polyacetal（only NC）,Stainless steel（only NA,NB）</td>
</tr>
<tr>
<th colspan="4">Cartridge</th>
<td colspan="4">Brass</td>
</tr>
<tr>
<th colspan="4">Housing</th>
<td colspan="4">NEMA4 drip-proof</td>
</tr>
<tr>
<th rowspan="6">Solenoid</th>
<th colspan="2" rowspan="2">Applicable voltage</th>
<th>AC</th>
<td colspan="4">100V , 110V , 115V , 120V</td>
</tr>
<tr>
<th>DC</th>
<td colspan="4">100V , 110V , 125V</td>
</tr>
<tr>
<th colspan="3">Allowable voltage fluctuation</th>
<td colspan="4">-15% to 10% of applicable voltage</td>
</tr>
<tr>
<th colspan="3">Insulation class</th>
<td colspan="4">Class H</td>
</tr>
<tr>
<th colspan="3">Leadwire length（mm）</th>
<td colspan="4">600</td>
</tr>
<tr>
<th colspan="3">Ambient temperature</th>
<td colspan="4">Refer to catalog for details.</td>
</tr>
<tr>
<th colspan="4">Installation position</th>
<td colspan="4">As desired（Horizontal mounting with solenoid at upper side is recommended）</td>
</tr>
<tr>
<th colspan="4">Options</th>
<td colspan="4">Mounting bracket , NPT（port） , Terminal box</td>
</tr>
</tbody>
</table>
<h1>External Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-26340" src="https://koueitrading.com/global/wp-content/uploads/2021/03/4-1.png" alt="" width="541" height="435" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/4-1.png 541w, https://koueitrading.com/global/wp-content/uploads/2021/03/4-1-300x241.png 300w" sizes="auto, (max-width: 541px) 100vw, 541px" /></p>
<h1>JIS Symbols</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-26341" src="https://koueitrading.com/global/wp-content/uploads/2021/03/1-4.png" alt="" width="346" height="129" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/1-4.png 346w, https://koueitrading.com/global/wp-content/uploads/2021/03/1-4-300x112.png 300w" sizes="auto, (max-width: 346px) 100vw, 346px" /></p>
<h1>Coil Data</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-26342 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/03/2-5.png" alt="NA/NB/NC204" width="444" height="168" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/2-5.png 444w, https://koueitrading.com/global/wp-content/uploads/2021/03/2-5-300x114.png 300w" sizes="auto, (max-width: 444px) 100vw, 444px" /></p>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-26343 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/03/3-4.png" alt="NA/NB/NC204" width="912" height="526" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/3-4.png 912w, https://koueitrading.com/global/wp-content/uploads/2021/03/3-4-300x173.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/03/3-4-768x443.png 768w" sizes="auto, (max-width: 912px) 100vw, 912px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-na-nb-nc204-3-port-solenoid-valves-for-nuclear-power-plants-normally-open/">KONAN NA/NB/NC204 3-port Solenoid Valves For Nuclear Power Plants Normally Open</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN NA/NB/NC336 3-port Solenoid Valves For Nuclear Power Plants Universal</title>
		<link>https://koueitrading.com/global/product/konan-na-nb-nc336-3-port-solenoid-valves-for-nuclear-power-plants-universal/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Tue, 09 Mar 2021 07:48:17 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=26336</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN Model: NA/NB/NC336 N33 series 3-port solenoid valves for nuclear power plants are small size direct-acting valves adopting soft seal. The compact valves control various fluids in normally closed, normally open, or universal type operation. Model Code External Dimensions JIS Symbols Coil Data &#160; Specification &#160; Model code NA/NB/NC333 NA/NB/NC334 NA/NB/NC336 [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-na-nb-nc336-3-port-solenoid-valves-for-nuclear-power-plants-universal/">KONAN NA/NB/NC336 3-port Solenoid Valves For Nuclear Power Plants Universal</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN<br />
Model: NA/NB/NC336</p>
<p><em><strong>N33 series 3-port solenoid valves for nuclear power plants are small size direct-acting valves adopting soft seal.</strong></em><br />
<em><b>The compact valves control various fluids in normally closed, normally open, or universal type operation.</b></em></p>
<h2>Model Code</h2>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-26330" src="https://koueitrading.com/global/wp-content/uploads/2021/03/3-3.png" alt="" width="894" height="606" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/3-3.png 894w, https://koueitrading.com/global/wp-content/uploads/2021/03/3-3-300x203.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/03/3-3-768x521.png 768w" sizes="auto, (max-width: 894px) 100vw, 894px" /></p>
<h2>External Dimensions</h2>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-26331" src="https://koueitrading.com/global/wp-content/uploads/2021/03/4.png" alt="" width="853" height="385" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/4.png 853w, https://koueitrading.com/global/wp-content/uploads/2021/03/4-300x135.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/03/4-768x347.png 768w" sizes="auto, (max-width: 853px) 100vw, 853px" /></p>
<h2>JIS Symbols</h2>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-26332" src="https://koueitrading.com/global/wp-content/uploads/2021/03/1-3.png" alt="" width="434" height="126" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/1-3.png 434w, https://koueitrading.com/global/wp-content/uploads/2021/03/1-3-300x87.png 300w" sizes="auto, (max-width: 434px) 100vw, 434px" /></p>
<h2>Coil Data</h2>
<p>&nbsp;</p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-26333" src="https://koueitrading.com/global/wp-content/uploads/2021/03/2-4.png" alt="" width="444" height="170" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/2-4.png 444w, https://koueitrading.com/global/wp-content/uploads/2021/03/2-4-300x115.png 300w" sizes="auto, (max-width: 444px) 100vw, 444px" /></p>
<h2>Specification</h2>
<p>&nbsp;</p>
<table>
<tbody>
<tr>
<th colspan="5">Model code</th>
<td colspan="4">NA/NB/NC333</td>
<td colspan="4">NA/NB/NC334</td>
<td colspan="4">NA/NB/NC336</td>
</tr>
<tr>
<th colspan="5">Valve operation type</th>
<td colspan="4">Normally closed</td>
<td colspan="4">Normally open</td>
<td colspan="4">Universal</td>
</tr>
<tr>
<th colspan="5">Port size</th>
<td colspan="4">Rc1/4</td>
<td colspan="4">Rc1/4</td>
<td colspan="4">Rc1/4</td>
</tr>
<tr>
<th colspan="5">Orifice size（mm）</th>
<td>1.6</td>
<td>2.4</td>
<td>3.2</td>
<td>4.4</td>
<td>1.6</td>
<td>2.4</td>
<td>3.2</td>
<td>4.4</td>
<td>1.6</td>
<td>2.4</td>
<td>3.2</td>
<td>4.4</td>
</tr>
<tr>
<th colspan="5">Cv value</th>
<td>0.09</td>
<td>0.15</td>
<td>0.31</td>
<td>0.38</td>
<td>0.09</td>
<td>0.15</td>
<td>0.31</td>
<td>0.38</td>
<td>0.09</td>
<td>0.15</td>
<td>0.31</td>
<td>0.38</td>
</tr>
<tr>
<th rowspan="5">Operating<br />
pressure<br />
differential<br />
（MPa）</th>
<th colspan="4">Min.</th>
<td colspan="12">0</td>
</tr>
<tr>
<th rowspan="4">Max.</th>
<th rowspan="4">Air/<br />
Inert gas</th>
<th rowspan="2">AC</th>
<th>low pressure</th>
<td>1.37</td>
<td>1.02</td>
<td>0.57</td>
<td>0.31</td>
<td>1.37</td>
<td>1.02</td>
<td>0.57</td>
<td>0.31</td>
<td>0.68</td>
<td>0.41</td>
<td>0.23</td>
<td>0.15</td>
</tr>
<tr>
<th>high pressure</th>
<td>1.71</td>
<td>1.17</td>
<td>0.75</td>
<td>0.37</td>
<td>1.71</td>
<td>1.17</td>
<td>0.75</td>
<td>0.37</td>
<td>0.94</td>
<td>0.75</td>
<td>0.34</td>
<td>0.29</td>
</tr>
<tr>
<th rowspan="2">DC</th>
<th>low pressure</th>
<td>1.09</td>
<td>0.78</td>
<td>0.41</td>
<td>0.16</td>
<td>1.09</td>
<td>0.78</td>
<td>0.41</td>
<td>0.16</td>
<td>0.54</td>
<td>0.34</td>
<td>0.20</td>
<td>0.078</td>
</tr>
<tr>
<th>high pressure</th>
<td>1.37</td>
<td>0.94</td>
<td>0.60</td>
<td>0.31</td>
<td>1.37</td>
<td>0.94</td>
<td>0.60</td>
<td>0.31</td>
<td>0.85</td>
<td>0.68</td>
<td>0.31</td>
<td>0.27</td>
</tr>
<tr>
<th colspan="5">Body</th>
<td colspan="12">Brass , stainless steel</td>
</tr>
<tr>
<th colspan="5">Elastomer</th>
<td colspan="12">Nitrile rubber（only NC）,Fluorine rubber（only NA,NB）,Ethylene propylene（only NA,NB）</td>
</tr>
<tr>
<th colspan="5">Poppet</th>
<td colspan="12">Polyacetal（only NC）,Stainless steel（only NA,NB）</td>
</tr>
<tr>
<th colspan="5">Housing</th>
<td colspan="12">NEMA4 drip-proof</td>
</tr>
<tr>
<th rowspan="6">Solenoid</th>
<th colspan="2" rowspan="2">Applicable voltage</th>
<th colspan="2">AC</th>
<td colspan="12">100V , 110V , 115V , 120V</td>
</tr>
<tr>
<th colspan="2">DC</th>
<td colspan="12">100V , 110V , 125V</td>
</tr>
<tr>
<th colspan="4">Allowable voltage fluctuation</th>
<td colspan="12">-15% to 10% of applicable voltage</td>
</tr>
<tr>
<th colspan="4">Insulation class</th>
<td colspan="12">Class H</td>
</tr>
<tr>
<th colspan="4">Leadwire length（mm）</th>
<td colspan="12">600</td>
</tr>
<tr>
<th colspan="4">Ambient temperature</th>
<td colspan="12">Refer to catalog for details.</td>
</tr>
<tr>
<th colspan="5">Installation position</th>
<td colspan="12">As desired（Horizontal mounting with solenoid at upper side is recommended）</td>
</tr>
<tr>
<th colspan="5">Options</th>
<td colspan="12">Mounting bracket , NPT（port） , Terminal box , operating system（only NC）</td>
</tr>
</tbody>
</table>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-na-nb-nc336-3-port-solenoid-valves-for-nuclear-power-plants-universal/">KONAN NA/NB/NC336 3-port Solenoid Valves For Nuclear Power Plants Universal</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN NA/NB/NC334 3-port Solenoid Valves For Nuclear Power Plants Normally Open</title>
		<link>https://koueitrading.com/global/product/konan-na-nb-nc334-3-port-solenoid-valves-for-nuclear-power-plants-normally-open/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Tue, 09 Mar 2021 07:48:15 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=26335</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: NA/NB/NC334 N33 series 3-port solenoid valves for nuclear power plants are small-size direct-acting valves adopting soft seals. The compact valves control various fluids in normally closed, normally open, or universal type operation. Model Code External Dimensions JIS Symbols Coil Data Specification Model code NA/NB/NC333 NA/NB/NC334 NA/NB/NC336 Valve [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-na-nb-nc334-3-port-solenoid-valves-for-nuclear-power-plants-normally-open/">KONAN NA/NB/NC334 3-port Solenoid Valves For Nuclear Power Plants Normally Open</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: NA/NB/NC334</p>
<p><em><strong>N33 series 3-port solenoid valves for nuclear power plants are small-size direct-acting valves adopting soft seals.</strong></em><br />
<em><strong>The compact valves control various fluids in normally closed, normally open, or universal type operation.</strong></em></p>
<h2>Model Code</h2>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-26330" src="https://koueitrading.com/global/wp-content/uploads/2021/03/3-3.png" alt="" width="894" height="606" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/3-3.png 894w, https://koueitrading.com/global/wp-content/uploads/2021/03/3-3-300x203.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/03/3-3-768x521.png 768w" sizes="auto, (max-width: 894px) 100vw, 894px" /></p>
<h2>External Dimensions</h2>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-26331" src="https://koueitrading.com/global/wp-content/uploads/2021/03/4.png" alt="" width="853" height="385" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/4.png 853w, https://koueitrading.com/global/wp-content/uploads/2021/03/4-300x135.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/03/4-768x347.png 768w" sizes="auto, (max-width: 853px) 100vw, 853px" /></p>
<h2>JIS Symbols</h2>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-26332" src="https://koueitrading.com/global/wp-content/uploads/2021/03/1-3.png" alt="" width="434" height="126" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/1-3.png 434w, https://koueitrading.com/global/wp-content/uploads/2021/03/1-3-300x87.png 300w" sizes="auto, (max-width: 434px) 100vw, 434px" /></p>
<h2>Coil Data</h2>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-26333" src="https://koueitrading.com/global/wp-content/uploads/2021/03/2-4.png" alt="" width="444" height="170" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/2-4.png 444w, https://koueitrading.com/global/wp-content/uploads/2021/03/2-4-300x115.png 300w" sizes="auto, (max-width: 444px) 100vw, 444px" /></p>
<h2>Specification</h2>
<table>
<tbody>
<tr>
<th colspan="5">Model code</th>
<td colspan="4">NA/NB/NC333</td>
<td colspan="4">NA/NB/NC334</td>
<td colspan="4">NA/NB/NC336</td>
</tr>
<tr>
<th colspan="5">Valve operation type</th>
<td colspan="4">Normally closed</td>
<td colspan="4">Normally open</td>
<td colspan="4">Universal</td>
</tr>
<tr>
<th colspan="5">Port size</th>
<td colspan="4">Rc1/4</td>
<td colspan="4">Rc1/4</td>
<td colspan="4">Rc1/4</td>
</tr>
<tr>
<th colspan="5">Orifice size（mm）</th>
<td>1.6</td>
<td>2.4</td>
<td>3.2</td>
<td>4.4</td>
<td>1.6</td>
<td>2.4</td>
<td>3.2</td>
<td>4.4</td>
<td>1.6</td>
<td>2.4</td>
<td>3.2</td>
<td>4.4</td>
</tr>
<tr>
<th colspan="5">Cv value</th>
<td>0.09</td>
<td>0.15</td>
<td>0.31</td>
<td>0.38</td>
<td>0.09</td>
<td>0.15</td>
<td>0.31</td>
<td>0.38</td>
<td>0.09</td>
<td>0.15</td>
<td>0.31</td>
<td>0.38</td>
</tr>
<tr>
<th rowspan="5">Operating<br />
pressure<br />
differential<br />
（MPa）</th>
<th colspan="4">Min.</th>
<td colspan="12">0</td>
</tr>
<tr>
<th rowspan="4">Max.</th>
<th rowspan="4">Air/<br />
Inert gas</th>
<th rowspan="2">AC</th>
<th>low pressure</th>
<td>1.37</td>
<td>1.02</td>
<td>0.57</td>
<td>0.31</td>
<td>1.37</td>
<td>1.02</td>
<td>0.57</td>
<td>0.31</td>
<td>0.68</td>
<td>0.41</td>
<td>0.23</td>
<td>0.15</td>
</tr>
<tr>
<th>high pressure</th>
<td>1.71</td>
<td>1.17</td>
<td>0.75</td>
<td>0.37</td>
<td>1.71</td>
<td>1.17</td>
<td>0.75</td>
<td>0.37</td>
<td>0.94</td>
<td>0.75</td>
<td>0.34</td>
<td>0.29</td>
</tr>
<tr>
<th rowspan="2">DC</th>
<th>low pressure</th>
<td>1.09</td>
<td>0.78</td>
<td>0.41</td>
<td>0.16</td>
<td>1.09</td>
<td>0.78</td>
<td>0.41</td>
<td>0.16</td>
<td>0.54</td>
<td>0.34</td>
<td>0.20</td>
<td>0.078</td>
</tr>
<tr>
<th>high pressure</th>
<td>1.37</td>
<td>0.94</td>
<td>0.60</td>
<td>0.31</td>
<td>1.37</td>
<td>0.94</td>
<td>0.60</td>
<td>0.31</td>
<td>0.85</td>
<td>0.68</td>
<td>0.31</td>
<td>0.27</td>
</tr>
<tr>
<th colspan="5">Body</th>
<td colspan="12">Brass , stainless steel</td>
</tr>
<tr>
<th colspan="5">Elastomer</th>
<td colspan="12">Nitrile rubber（only NC）,Fluorine rubber（only NA,NB）,Ethylene propylene（only NA,NB）</td>
</tr>
<tr>
<th colspan="5">Poppet</th>
<td colspan="12">Polyacetal（only NC）,Stainless steel（only NA,NB）</td>
</tr>
<tr>
<th colspan="5">Housing</th>
<td colspan="12">NEMA4 drip-proof</td>
</tr>
<tr>
<th rowspan="6">Solenoid</th>
<th colspan="2" rowspan="2">Applicable voltage</th>
<th colspan="2">AC</th>
<td colspan="12">100V , 110V , 115V , 120V</td>
</tr>
<tr>
<th colspan="2">DC</th>
<td colspan="12">100V , 110V , 125V</td>
</tr>
<tr>
<th colspan="4">Allowable voltage fluctuation</th>
<td colspan="12">-15% to 10% of applicable voltage</td>
</tr>
<tr>
<th colspan="4">Insulation class</th>
<td colspan="12">Class H</td>
</tr>
<tr>
<th colspan="4">Leadwire length（mm）</th>
<td colspan="12">600</td>
</tr>
<tr>
<th colspan="4">Ambient temperature</th>
<td colspan="12">Refer to catalog for details.</td>
</tr>
<tr>
<th colspan="5">Installation position</th>
<td colspan="12">As desired（Horizontal mounting with solenoid at upper side is recommended）</td>
</tr>
<tr>
<th colspan="5">Options</th>
<td colspan="12">Mounting bracket , NPT（port） , Terminal box , operating system（only NC）</td>
</tr>
</tbody>
</table>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-na-nb-nc334-3-port-solenoid-valves-for-nuclear-power-plants-normally-open/">KONAN NA/NB/NC334 3-port Solenoid Valves For Nuclear Power Plants Normally Open</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN 454S/454D Series 5-Port Solenoid Valves Individual Exhaust Manifold Type</title>
		<link>https://koueitrading.com/global/product/konan-454s-454d-series-5-port-solenoid-valves-individual-exhaust-manifold-type/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Tue, 09 Mar 2021 07:17:38 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25496</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: 454S/454D Series This is the quick mounting manifold type solenoid valve in which R1 and R2（exhaust）ports can be individually taken out together with the solenoid valve. This type is optimum in case when to control connected load（air cylinder）&#8217;s speed with the exhaust valve（ exhaust throttling valve) Model [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-454s-454d-series-5-port-solenoid-valves-individual-exhaust-manifold-type/">KONAN 454S/454D Series 5-Port Solenoid Valves Individual Exhaust Manifold Type</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: 454S/454D Series</p>
<p><strong>This is the quick mounting manifold type solenoid </strong><strong>valve in which R1 and R2（exhaust）ports can be </strong><strong>individually taken out together with the solenoid valve.</strong><br />
<strong>This type is optimum in case when to control </strong><strong>connected load（air cylinder）&#8217;s speed with the </strong><strong>exhaust valve（ exhaust throttling valve)</strong></p>
<h2>Model Code</h2>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25497 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-49.png" alt="454S/454D Series" width="922" height="806" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-49.png 922w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-49-300x262.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-49-768x671.png 768w" sizes="auto, (max-width: 922px) 100vw, 922px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-25498 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-85.png" alt="454S/454D Series" width="902" height="347" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-85.png 902w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-85-300x115.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-85-768x295.png 768w" sizes="auto, (max-width: 902px) 100vw, 902px" /></p>
<h2>Outside Dimensions</h2>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-25499" src="https://koueitrading.com/global/wp-content/uploads/2021/02/2-32.png" alt="" width="951" height="342" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/2-32.png 951w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-32-300x108.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-32-768x276.png 768w" sizes="auto, (max-width: 951px) 100vw, 951px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-25500 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/1-50.png" alt="454S/454D Series" width="912" height="836" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/1-50.png 912w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-50-300x275.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-50-768x704.png 768w" sizes="auto, (max-width: 912px) 100vw, 912px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-454s-454d-series-5-port-solenoid-valves-individual-exhaust-manifold-type/">KONAN 454S/454D Series 5-Port Solenoid Valves Individual Exhaust Manifold Type</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN NC211 2-port Solenoid Valves For Nuclear Power Plants Normally Closed</title>
		<link>https://koueitrading.com/global/product/konan-nc211-2-port-solenoid-valves-for-nuclear-power-plants-normally-closed/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Tue, 09 Mar 2021 04:40:26 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=26290</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN Model: NC211 N21 series 2-port solenoid valves for nuclear power plants are pilot-type valves incorporating diaphragm. Specification Model code NC211 NC212 Valve operation type Normally closed Normally open Port size Rc1/2 Rc3/4 Rc 1 Rc3/8 Rc1/2 Rc3/4 Orifice size（mm） 15.9 19.1 25.4 15.9 15.9 19.1 Cv value 4.1 5.5 [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-nc211-2-port-solenoid-valves-for-nuclear-power-plants-normally-closed/">KONAN NC211 2-port Solenoid Valves For Nuclear Power Plants Normally Closed</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN<br />
Model: NC211</p>
<p>N21 series 2-port solenoid valves for nuclear power plants are pilot-type valves incorporating diaphragm.</p>
<h1>Specification</h1>
<table>
<tbody>
<tr>
<th colspan="4">Model code</th>
<td colspan="3">NC211</td>
<td colspan="3">NC212</td>
</tr>
<tr>
<th colspan="4">Valve operation type</th>
<td colspan="3">Normally closed</td>
<td colspan="3">Normally open</td>
</tr>
<tr>
<th colspan="4">Port size</th>
<td>Rc1/2</td>
<td>Rc3/4</td>
<td>Rc 1</td>
<td>Rc3/8</td>
<td>Rc1/2</td>
<td>Rc3/4</td>
</tr>
<tr>
<th colspan="4">Orifice size（mm）</th>
<td>15.9</td>
<td>19.1</td>
<td>25.4</td>
<td>15.9</td>
<td>15.9</td>
<td>19.1</td>
</tr>
<tr>
<th colspan="4">Cv value</th>
<td>4.1</td>
<td>5.5</td>
<td>13.0</td>
<td>3.3</td>
<td>4.1</td>
<td>5.5</td>
</tr>
<tr>
<th rowspan="3">Operating<br />
pressure<br />
differential<br />
（MPa）</th>
<th colspan="3">Min.</th>
<td>0.02</td>
<td>0.02</td>
<td>0.03</td>
<td>0.02</td>
<td>0.02</td>
<td>0.02</td>
</tr>
<tr>
<th rowspan="2">Max.</th>
<th rowspan="2">Air/Inert gas</th>
<th>AC</th>
<td>1.37</td>
<td>1.37</td>
<td>1.37</td>
<td>0.68</td>
<td>0.68</td>
<td>0.68</td>
</tr>
<tr>
<th>DC</th>
<td>1.02</td>
<td>1.02</td>
<td>1.02</td>
<td>0.68</td>
<td>0.68</td>
<td>0.68</td>
</tr>
<tr>
<th colspan="4">Body</th>
<td colspan="6">Brass</td>
</tr>
<tr>
<th colspan="4">Elastomer</th>
<td colspan="6">Nitrile rubber</td>
</tr>
<tr>
<th colspan="4">Housing</th>
<td colspan="6">NEMA4 drip-proof</td>
</tr>
<tr>
<th rowspan="6">Solenoid</th>
<th colspan="2" rowspan="2">Applicable voltage</th>
<th>AC</th>
<td colspan="6">100V , 110V , 115V , 120V</td>
</tr>
<tr>
<th>DC</th>
<td colspan="6">100V , 110V , 125V</td>
</tr>
<tr>
<th colspan="3">Allowable voltage fluctuation</th>
<td colspan="6">-15% to 10% of applicable voltage</td>
</tr>
<tr>
<th colspan="3">Insulation class</th>
<td colspan="6">Class H</td>
</tr>
<tr>
<th colspan="3">Leadwire length（mm）</th>
<td colspan="6">600</td>
</tr>
<tr>
<th colspan="3">Ambient temperature</th>
<td colspan="6">Refer to catalog for details.</td>
</tr>
<tr>
<th colspan="4">Installation position</th>
<td colspan="6">As desired（Horizontal mounting with solenoid at upper side is recommended）</td>
</tr>
<tr>
<th colspan="4">Options</th>
<td colspan="6">Mounting bracket , NPT（port） , Terminal box</td>
</tr>
</tbody>
</table>
<h1>JIS Symbols</h1>
<h1><img loading="lazy" decoding="async" class="alignnone wp-image-26293 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/03/1-2.png" alt="NC211" width="320" height="122" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/1-2.png 320w, https://koueitrading.com/global/wp-content/uploads/2021/03/1-2-300x114.png 300w" sizes="auto, (max-width: 320px) 100vw, 320px" /></h1>
<h1>Coil Data</h1>
<h1><img loading="lazy" decoding="async" class="alignnone wp-image-26294 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/03/2-3.png" alt="NC211" width="439" height="214" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/2-3.png 439w, https://koueitrading.com/global/wp-content/uploads/2021/03/2-3-300x146.png 300w" sizes="auto, (max-width: 439px) 100vw, 439px" /></h1>
<h1>External Dimensions</h1>
<h1><img loading="lazy" decoding="async" class="alignnone wp-image-26295 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/03/3-2.png" alt="NC211" width="853" height="419" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/3-2.png 853w, https://koueitrading.com/global/wp-content/uploads/2021/03/3-2-300x147.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/03/3-2-768x377.png 768w" sizes="auto, (max-width: 853px) 100vw, 853px" /></h1>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-nc211-2-port-solenoid-valves-for-nuclear-power-plants-normally-closed/">KONAN NC211 2-port Solenoid Valves For Nuclear Power Plants Normally Closed</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN NC212 2-port Solenoid Valves For Nuclear Power Plants Normally Open</title>
		<link>https://koueitrading.com/global/product/konan-nc212-2-port-solenoid-valves-for-nuclear-power-plants-normally-open/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Tue, 09 Mar 2021 04:38:25 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=26297</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: NC212 N21 series 2-port solenoid valves for nuclear power plants are pilot-type valves incorporating a diaphragm. Specification Model code NC211 NC212 Valve operation type Normally closed Normally open Port size Rc1/2 Rc3/4 Rc 1 Rc3/8 Rc1/2 Rc3/4 Orifice size（mm） 15.9 19.1 25.4 15.9 15.9 19.1 Cv value [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-nc212-2-port-solenoid-valves-for-nuclear-power-plants-normally-open/">KONAN NC212 2-port Solenoid Valves For Nuclear Power Plants Normally Open</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: NC212</p>
<p>N21 series 2-port solenoid valves for nuclear power plants are pilot-type valves incorporating a diaphragm.</p>
<h1>Specification</h1>
<table>
<tbody>
<tr>
<th colspan="4">Model code</th>
<td colspan="3">NC211</td>
<td colspan="3">NC212</td>
</tr>
<tr>
<th colspan="4">Valve operation type</th>
<td colspan="3">Normally closed</td>
<td colspan="3">Normally open</td>
</tr>
<tr>
<th colspan="4">Port size</th>
<td>Rc1/2</td>
<td>Rc3/4</td>
<td>Rc 1</td>
<td>Rc3/8</td>
<td>Rc1/2</td>
<td>Rc3/4</td>
</tr>
<tr>
<th colspan="4">Orifice size（mm）</th>
<td>15.9</td>
<td>19.1</td>
<td>25.4</td>
<td>15.9</td>
<td>15.9</td>
<td>19.1</td>
</tr>
<tr>
<th colspan="4">Cv value</th>
<td>4.1</td>
<td>5.5</td>
<td>13.0</td>
<td>3.3</td>
<td>4.1</td>
<td>5.5</td>
</tr>
<tr>
<th rowspan="3">Operating<br />
pressure<br />
differential<br />
（MPa）</th>
<th colspan="3">Min.</th>
<td>0.02</td>
<td>0.02</td>
<td>0.03</td>
<td>0.02</td>
<td>0.02</td>
<td>0.02</td>
</tr>
<tr>
<th rowspan="2">Max.</th>
<th rowspan="2">Air/Inert gas</th>
<th>AC</th>
<td>1.37</td>
<td>1.37</td>
<td>1.37</td>
<td>0.68</td>
<td>0.68</td>
<td>0.68</td>
</tr>
<tr>
<th>DC</th>
<td>1.02</td>
<td>1.02</td>
<td>1.02</td>
<td>0.68</td>
<td>0.68</td>
<td>0.68</td>
</tr>
<tr>
<th colspan="4">Body</th>
<td colspan="6">Brass</td>
</tr>
<tr>
<th colspan="4">Elastomer</th>
<td colspan="6">Nitrile rubber</td>
</tr>
<tr>
<th colspan="4">Housing</th>
<td colspan="6">NEMA4 drip-proof</td>
</tr>
<tr>
<th rowspan="6">Solenoid</th>
<th colspan="2" rowspan="2">Applicable voltage</th>
<th>AC</th>
<td colspan="6">100V , 110V , 115V , 120V</td>
</tr>
<tr>
<th>DC</th>
<td colspan="6">100V , 110V , 125V</td>
</tr>
<tr>
<th colspan="3">Allowable voltage fluctuation</th>
<td colspan="6">-15% to 10% of applicable voltage</td>
</tr>
<tr>
<th colspan="3">Insulation class</th>
<td colspan="6">Class H</td>
</tr>
<tr>
<th colspan="3">Leadwire length（mm）</th>
<td colspan="6">600</td>
</tr>
<tr>
<th colspan="3">Ambient temperature</th>
<td colspan="6">Refer to catalog for details.</td>
</tr>
<tr>
<th colspan="4">Installation position</th>
<td colspan="6">As desired（Horizontal mounting with solenoid at upper side is recommended）</td>
</tr>
<tr>
<th colspan="4">Options</th>
<td colspan="6">Mounting bracket , NPT（port） , Terminal box</td>
</tr>
</tbody>
</table>
<h1>JIS Symbols</h1>
<h1><img loading="lazy" decoding="async" class="alignnone size-full wp-image-26293" src="https://koueitrading.com/global/wp-content/uploads/2021/03/1-2.png" alt="" width="320" height="122" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/1-2.png 320w, https://koueitrading.com/global/wp-content/uploads/2021/03/1-2-300x114.png 300w" sizes="auto, (max-width: 320px) 100vw, 320px" /></h1>
<h1>Coil Data</h1>
<h1><img loading="lazy" decoding="async" class="alignnone size-full wp-image-26294" src="https://koueitrading.com/global/wp-content/uploads/2021/03/2-3.png" alt="" width="439" height="214" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/2-3.png 439w, https://koueitrading.com/global/wp-content/uploads/2021/03/2-3-300x146.png 300w" sizes="auto, (max-width: 439px) 100vw, 439px" /></h1>
<h1>External Dimensions</h1>
<h1><img loading="lazy" decoding="async" class="alignnone size-full wp-image-26295" src="https://koueitrading.com/global/wp-content/uploads/2021/03/3-2.png" alt="" width="853" height="419" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/3-2.png 853w, https://koueitrading.com/global/wp-content/uploads/2021/03/3-2-300x147.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/03/3-2-768x377.png 768w" sizes="auto, (max-width: 853px) 100vw, 853px" /></h1>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-nc212-2-port-solenoid-valves-for-nuclear-power-plants-normally-open/">KONAN NC212 2-port Solenoid Valves For Nuclear Power Plants Normally Open</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN 414S/416S Series 5-Port Solenoid Valves Intrinsic Safety Construction Return Type</title>
		<link>https://koueitrading.com/global/product/konan-414s-416s-series-5-port-solenoid-valves-intrinsic-safety-construction-return-type/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Tue, 09 Mar 2021 04:05:14 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25491</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: 414S/416S Series Specifications Return Type 414S30 □ M 414S60 □ M 416S30 □ M 416S60 □ M Port size（Rc） 1/4 3/8 1/2 1/4 3/8 1/2 Effective sectional area（㎟ ) 25 30 51 60 24 28 51 60 Operating pressure 0.2 〜 0.7MPa 0.12 〜 0.7MPa Pressure resistance [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-414s-416s-series-5-port-solenoid-valves-intrinsic-safety-construction-return-type/">KONAN 414S/416S Series 5-Port Solenoid Valves Intrinsic Safety Construction Return Type</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: 414S/416S Series</p>
<h1>Specifications</h1>
<table>
<tbody>
<tr>
<td colspan="2" width="193"></td>
<td colspan="8" width="491">Return</td>
</tr>
<tr>
<td colspan="2" width="193">Type</td>
<td colspan="2" width="123">414S30 □ M</td>
<td colspan="2" width="123">414S60 □ M</td>
<td colspan="2" width="123">416S30 □ M</td>
<td colspan="2" width="123">416S60 □ M</td>
</tr>
<tr>
<td colspan="2" width="193">Port size（Rc）</td>
<td width="61">1/4</td>
<td colspan="2" width="123">3/8</td>
<td width="61">1/2</td>
<td width="61">1/4</td>
<td colspan="2" width="123">3/8</td>
<td width="61">1/2</td>
</tr>
<tr>
<td colspan="2" width="193">Effective sectional area（㎟ )</td>
<td width="61">25</td>
<td width="61">30</td>
<td width="61">51</td>
<td width="61">60</td>
<td width="61">24</td>
<td width="61">28</td>
<td width="61">51</td>
<td width="61">60</td>
</tr>
<tr>
<td colspan="2" width="193">Operating pressure</td>
<td colspan="4" width="246">0.2 〜 0.7MPa</td>
<td colspan="4" width="246">0.12 〜 0.7MPa</td>
</tr>
<tr>
<td colspan="2" width="193">Pressure resistance</td>
<td colspan="8" width="491">1.05MPa</td>
</tr>
<tr>
<td colspan="2" width="193">Operating temperature</td>
<td colspan="4" width="246">− 5〜 50℃</td>
<td colspan="4" width="246">− 10 〜 60℃</td>
</tr>
<tr>
<td colspan="2" width="193">Operating frequency</td>
<td colspan="8" width="491">1 cycle / s max.</td>
</tr>
<tr>
<td colspan="2" width="193">Operation（response）time</td>
<td colspan="2" width="123">0.14 s max.</td>
<td colspan="2" width="123">0.16 s max.</td>
<td colspan="2" width="123">0.14 s max.</td>
<td colspan="2" width="123">0.16 s max.</td>
</tr>
<tr>
<td rowspan="6" width="77"><strong> </strong></p>
<p><strong> </strong></p>
<p>Solenoid</td>
<td width="115">Rated voltage</td>
<td colspan="8" width="491">DC12V・34mA −（Intrinsic safety Circuit Rating）</td>
</tr>
<tr>
<td width="115">Temperature rise</td>
<td colspan="8" width="491">12 deg max.</td>
</tr>
<tr>
<td width="115">Insulation class</td>
<td colspan="8" width="491">Class B</td>
</tr>
<tr>
<td width="115">Insulation resistance</td>
<td colspan="8" width="491">10MΩ min.（DC500V）</td>
</tr>
<tr>
<td width="115">Power consumption</td>
<td colspan="8" width="491">0.4W</td>
</tr>
<tr>
<td width="115">Explosion-proof standard</td>
<td colspan="8" width="491">Intrinsic safety construction： Exia Ⅱ BT5</td>
</tr>
<tr>
<td colspan="2" width="193">Mass（kg）</td>
<td colspan="2" width="123">Approx.1.3</td>
<td colspan="2" width="123">Approx.2.2</td>
<td colspan="2" width="123">Approx.1.3</td>
<td colspan="2" width="123">Approx.2.2</td>
</tr>
<tr>
<td colspan="2" width="193"><strong> </strong></p>
<p>Explosion-proof verification approval No.</td>
<td colspan="8" width="491">When combined with explosion-proof barriers satisfying the conditions mentioned in pages D-6, D-8: No. TC14814 When combined with the safety barrier, MTL728+: No. T42154</td>
</tr>
<tr>
<td colspan="2" width="193"><strong> </strong></p>
<p><strong> </strong></p>
<p>Use conditions</td>
<td colspan="8" width="491">(1)   Use in combination with specified safety barriers.</p>
<p>Use the explosion-proof barrier in combination with the SAF3-5, SAF100-5 or the barrier satisfying the condition specified in pages D-6,D-8 [When selecting other explosion-proof barriers].</p>
<p>(2)   The parts and the wiring cannot be changed.</p>
<p>(3)   In combination with one electromagnetic valve, use one explosion-proof barrier alone.</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h1>Outside Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25492 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-48.png" alt="414S/416S Series" width="915" height="685" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-48.png 915w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-48-300x225.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-48-768x575.png 768w" sizes="auto, (max-width: 915px) 100vw, 915px" /></p>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25493 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-84.png" alt="414S/416S Series" width="650" height="294" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-84.png 650w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-84-300x136.png 300w" sizes="auto, (max-width: 650px) 100vw, 650px" /></p>
<h1>Wire connection diagram</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25494 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-40.png" alt="414S/416S Series" width="508" height="185" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-40.png 508w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-40-300x109.png 300w" sizes="auto, (max-width: 508px) 100vw, 508px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-414s-416s-series-5-port-solenoid-valves-intrinsic-safety-construction-return-type/">KONAN 414S/416S Series 5-Port Solenoid Valves Intrinsic Safety Construction Return Type</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN NA321 3-port Solenoid Valves For Nuclear Power Plants Normally Closed</title>
		<link>https://koueitrading.com/global/product/konan-na321-3-port-solenoid-valves-for-nuclear-power-plants-normally-closed/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Tue, 09 Mar 2021 02:57:42 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=26347</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: NA321 YS32 series pilot-operated piston style 3-port solenoid valves show distinguished performance in high flow rate applications. The valves have a large orifice. The valves have high reliability as quick exhaust valves. Specification Model code NA321 NA322 Valve operation type Normally closed Normally open Port size Rc1/4 [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-na321-3-port-solenoid-valves-for-nuclear-power-plants-normally-closed/">KONAN NA321 3-port Solenoid Valves For Nuclear Power Plants Normally Closed</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: NA321</p>
<p>YS32 series pilot-operated piston style 3-port solenoid valves show distinguished performance in high flow rate applications.<br />
The valves have a large orifice. The valves have high reliability as quick exhaust valves.</p>
<h1>Specification</h1>
<table>
<tbody>
<tr>
<th colspan="4">Model code</th>
<td style="text-align: center;" colspan="2">NA321</td>
<td style="text-align: center;" colspan="2">NA322</td>
</tr>
<tr>
<th style="text-align: center;" colspan="4">Valve operation type</th>
<td style="text-align: center;" colspan="2">Normally closed</td>
<td style="text-align: center;" colspan="2">Normally open</td>
</tr>
<tr>
<th colspan="4">Port size</th>
<td style="text-align: center;">Rc1/4</td>
<td style="text-align: center;">Rc3/8</td>
<td style="text-align: center;">Rc1/4</td>
<td style="text-align: center;">Rc3/8</td>
</tr>
<tr>
<th colspan="4">Orifice size（mm）</th>
<td style="text-align: center;" colspan="4">Pressure side:7.1 Exhaust side:8.7</td>
</tr>
<tr>
<th style="text-align: center;" colspan="4">Cv value</th>
<td style="text-align: center;" colspan="4">Pressure side:0.8 Exhaust side:1.2</td>
</tr>
<tr>
<th rowspan="3">Operating<br />
pressure<br />
differential<br />
（MPa）</th>
<th colspan="3">Min.</th>
<td style="text-align: center;" colspan="4">0.07</td>
</tr>
<tr>
<th rowspan="2">Max.</th>
<th rowspan="2">Air/Inert gas</th>
<th>AC</th>
<td style="text-align: center;" colspan="4">0.85</td>
</tr>
<tr>
<th>DC</th>
<td style="text-align: center;" colspan="4">0.85</td>
</tr>
<tr>
<th colspan="4">Body</th>
<td style="text-align: center;" colspan="4">Brass</td>
</tr>
<tr>
<th colspan="4">Seal / seat</th>
<td style="text-align: center;" colspan="4">Nitrile rubber（only NC）,Fluorine rubber（only NA,NB）</td>
</tr>
<tr>
<th colspan="4">Poppet</th>
<td style="text-align: center;" colspan="4">Polyacetal（only NC）,Stainless steel（only NA,NB）</td>
</tr>
<tr>
<th colspan="4">Cartridge</th>
<td style="text-align: center;" colspan="4">Brass</td>
</tr>
<tr>
<th colspan="4">Housing</th>
<td style="text-align: center;" colspan="4">NEMA4 drip-proof</td>
</tr>
<tr>
<th rowspan="6">Solenoid</th>
<th colspan="2" rowspan="2">Applicable voltage</th>
<th>AC</th>
<td style="text-align: center;" colspan="4">100V , 110V , 115V , 120V</td>
</tr>
<tr>
<th>DC</th>
<td style="text-align: center;" colspan="4">100V , 110V , 125V</td>
</tr>
<tr>
<th colspan="3">Allowable voltage fluctuation</th>
<td style="text-align: center;" colspan="4">-15% to 10% of applicable voltage</td>
</tr>
<tr>
<th colspan="3">Insulation class</th>
<td style="text-align: center;" colspan="4">Class H</td>
</tr>
<tr>
<th colspan="3">Leadwire length（mm）</th>
<td style="text-align: center;" colspan="4">600</td>
</tr>
<tr>
<th colspan="3">Ambient temperature</th>
<td style="text-align: center;" colspan="4">Refer to catalogue for details.</td>
</tr>
<tr>
<th colspan="4">Installation position</th>
<td style="text-align: center;" colspan="4">As desired（Horizontal mounting with solenoid at the upper side is recommended）</td>
</tr>
<tr>
<th colspan="4">Options</th>
<td style="text-align: center;" colspan="4">Terminal box , NPT（port）</td>
</tr>
</tbody>
</table>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-na321-3-port-solenoid-valves-for-nuclear-power-plants-normally-closed/">KONAN NA321 3-port Solenoid Valves For Nuclear Power Plants Normally Closed</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN NA/NB/NC203 3-port Solenoid Valves For Nuclear Power Plants Normally Closed</title>
		<link>https://koueitrading.com/global/product/konan-na-nb-nc203-3-port-solenoid-valves-for-nuclear-power-plants-normally-closed/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Tue, 09 Mar 2021 01:27:39 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=26339</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: NA/NB/NC203 N203/204 series 3-port solenoid valves for nuclear power plants are pilot type valves incorporating diaphragm. With high flow rate structure and operation at low differential pressure,the valves ensure excellent control reliability. Specification Model code NA/NB/NC203 NA/NB/NC204 Valve operation type Normally closed Normally open Port size Rc3/8 [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-na-nb-nc203-3-port-solenoid-valves-for-nuclear-power-plants-normally-closed/">KONAN NA/NB/NC203 3-port Solenoid Valves For Nuclear Power Plants Normally Closed</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: NA/NB/NC203</p>
<p>N203/204 series 3-port solenoid valves for nuclear power plants are pilot type valves incorporating diaphragm.<br />
With high flow rate structure and operation at low differential pressure,the valves ensure excellent control reliability.</p>
<h2>Specification</h2>
<table>
<tbody>
<tr>
<th colspan="4">Model code</th>
<td colspan="2">NA/NB/NC203</td>
<td colspan="2">NA/NB/NC204</td>
</tr>
<tr>
<th colspan="4">Valve operation type</th>
<td colspan="2">Normally closed</td>
<td colspan="2">Normally open</td>
</tr>
<tr>
<th colspan="4">Port size</th>
<td>Rc3/8</td>
<td>Rc1/2</td>
<td>Rc3/8</td>
<td>Rc1/2</td>
</tr>
<tr>
<th colspan="4">Orifice size（mm）</th>
<td colspan="2">15.9</td>
<td colspan="2">15.9</td>
</tr>
<tr>
<th colspan="4">Cv value</th>
<td>3.3</td>
<td>4.4</td>
<td>3.3</td>
<td>4.4</td>
</tr>
<tr>
<th rowspan="3">Operating<br />
pressure<br />
differential<br />
（MPa）</th>
<th colspan="3">Min.</th>
<td colspan="4">0.05</td>
</tr>
<tr>
<th rowspan="2">Max.</th>
<th rowspan="2">Air/Inert gas</th>
<th>AC</th>
<td colspan="4">1.02</td>
</tr>
<tr>
<th>DC</th>
<td colspan="4">1.02</td>
</tr>
<tr>
<th colspan="4">Body</th>
<td colspan="4">Brass</td>
</tr>
<tr>
<th colspan="4">Seal / seat</th>
<td colspan="4">Nitrile rubber（only NC）,Fluorine rubber（only NA,NB）,Ethylene propylene（only NA,NB）</td>
</tr>
<tr>
<th colspan="4">Poppet</th>
<td colspan="4">Polyacetal（only NC）,Stainless steel（only NA,NB）</td>
</tr>
<tr>
<th colspan="4">Cartridge</th>
<td colspan="4">Brass</td>
</tr>
<tr>
<th colspan="4">Housing</th>
<td colspan="4">NEMA4 drip-proof</td>
</tr>
<tr>
<th rowspan="6">Solenoid</th>
<th colspan="2" rowspan="2">Applicable voltage</th>
<th>AC</th>
<td colspan="4">100V , 110V , 115V , 120V</td>
</tr>
<tr>
<th>DC</th>
<td colspan="4">100V , 110V , 125V</td>
</tr>
<tr>
<th colspan="3">Allowable voltage fluctuation</th>
<td colspan="4">-15% to 10% of applicable voltage</td>
</tr>
<tr>
<th colspan="3">Insulation class</th>
<td colspan="4">Class H</td>
</tr>
<tr>
<th colspan="3">Leadwire length（mm）</th>
<td colspan="4">600</td>
</tr>
<tr>
<th colspan="3">Ambient temperature</th>
<td colspan="4">Refer to catalog for details.</td>
</tr>
<tr>
<th colspan="4">Installation position</th>
<td colspan="4">As desired（Horizontal mounting with solenoid at upper side is recommended）</td>
</tr>
<tr>
<th colspan="4">Options</th>
<td colspan="4">Mounting bracket , NPT（port） , Terminal box</td>
</tr>
</tbody>
</table>
<h2>External Dimensions</h2>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-26340 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/03/4-1.png" alt="NA/NB/NC203" width="541" height="435" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/4-1.png 541w, https://koueitrading.com/global/wp-content/uploads/2021/03/4-1-300x241.png 300w" sizes="auto, (max-width: 541px) 100vw, 541px" /></p>
<h2>JIS Symbols</h2>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-26341 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/03/1-4.png" alt="NA/NB/NC203" width="346" height="129" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/1-4.png 346w, https://koueitrading.com/global/wp-content/uploads/2021/03/1-4-300x112.png 300w" sizes="auto, (max-width: 346px) 100vw, 346px" /></p>
<h2>Coil Data</h2>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-26342 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/03/2-5.png" alt="NA/NB/NC203" width="444" height="168" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/2-5.png 444w, https://koueitrading.com/global/wp-content/uploads/2021/03/2-5-300x114.png 300w" sizes="auto, (max-width: 444px) 100vw, 444px" /></p>
<h2>Model Code</h2>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-26343 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/03/3-4.png" alt="NA/NB/NC203" width="912" height="526" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/3-4.png 912w, https://koueitrading.com/global/wp-content/uploads/2021/03/3-4-300x173.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/03/3-4-768x443.png 768w" sizes="auto, (max-width: 912px) 100vw, 912px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-na-nb-nc203-3-port-solenoid-valves-for-nuclear-power-plants-normally-closed/">KONAN NA/NB/NC203 3-port Solenoid Valves For Nuclear Power Plants Normally Closed</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN NA/NB/NC333 3-port Solenoid Valves For Nuclear Power Plants Normally Closed</title>
		<link>https://koueitrading.com/global/product/konan-na-nb-nc333-3-port-solenoid-valves-for-nuclear-power-plants-normally-closed/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Mon, 08 Mar 2021 23:35:34 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=26306</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: NA/NB/NC333 N33 series 3-port solenoid valves for nuclear power plants are small-size direct-acting valves adopting soft seals. The compact valves control various fluids in normally closed, normally open, or universal type operation. Model Code External Dimensions &#160; &#160; JIS Symbols Coil Data Specification Model code NA/NB/NC333 NA/NB/NC334 [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-na-nb-nc333-3-port-solenoid-valves-for-nuclear-power-plants-normally-closed/">KONAN NA/NB/NC333 3-port Solenoid Valves For Nuclear Power Plants Normally Closed</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: NA/NB/NC333</p>
<p>N33 series 3-port solenoid valves for nuclear power plants are small-size direct-acting valves adopting soft seals.<br />
The compact valves control various fluids in normally closed, normally open, or universal type operation.</p>
<h2>Model Code</h2>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-26330 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/03/3-3.png" alt="NA/NB/NC333" width="894" height="606" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/3-3.png 894w, https://koueitrading.com/global/wp-content/uploads/2021/03/3-3-300x203.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/03/3-3-768x521.png 768w" sizes="auto, (max-width: 894px) 100vw, 894px" /></p>
<h2>External Dimensions</h2>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-26331 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/03/4.png" alt="NA/NB/NC333" width="853" height="385" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/4.png 853w, https://koueitrading.com/global/wp-content/uploads/2021/03/4-300x135.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/03/4-768x347.png 768w" sizes="auto, (max-width: 853px) 100vw, 853px" /></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<h2>JIS Symbols</h2>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-26332 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/03/1-3.png" alt="NA/NB/NC333" width="434" height="126" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/1-3.png 434w, https://koueitrading.com/global/wp-content/uploads/2021/03/1-3-300x87.png 300w" sizes="auto, (max-width: 434px) 100vw, 434px" /></p>
<h2>Coil Data</h2>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-26333 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/03/2-4.png" alt="NA/NB/NC333" width="444" height="170" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/2-4.png 444w, https://koueitrading.com/global/wp-content/uploads/2021/03/2-4-300x115.png 300w" sizes="auto, (max-width: 444px) 100vw, 444px" /></p>
<h1>Specification</h1>
<table>
<tbody>
<tr>
<th colspan="5">Model code</th>
<td colspan="4">NA/NB/NC333</td>
<td colspan="4">NA/NB/NC334</td>
<td colspan="4">NA/NB/NC336</td>
</tr>
<tr>
<th colspan="5">Valve operation type</th>
<td colspan="4">Normally closed</td>
<td colspan="4">Normally open</td>
<td colspan="4">Universal</td>
</tr>
<tr>
<th colspan="5">Port size</th>
<td colspan="4">Rc1/4</td>
<td colspan="4">Rc1/4</td>
<td colspan="4">Rc1/4</td>
</tr>
<tr>
<th colspan="5">Orifice size（mm）</th>
<td>1.6</td>
<td>2.4</td>
<td>3.2</td>
<td>4.4</td>
<td>1.6</td>
<td>2.4</td>
<td>3.2</td>
<td>4.4</td>
<td>1.6</td>
<td>2.4</td>
<td>3.2</td>
<td>4.4</td>
</tr>
<tr>
<th colspan="5">Cv value</th>
<td>0.09</td>
<td>0.15</td>
<td>0.31</td>
<td>0.38</td>
<td>0.09</td>
<td>0.15</td>
<td>0.31</td>
<td>0.38</td>
<td>0.09</td>
<td>0.15</td>
<td>0.31</td>
<td>0.38</td>
</tr>
<tr>
<th rowspan="5">Operating<br />
pressure<br />
differential<br />
（MPa）</th>
<th colspan="4">Min.</th>
<td colspan="12">0</td>
</tr>
<tr>
<th rowspan="4">Max.</th>
<th rowspan="4">Air/<br />
Inert gas</th>
<th rowspan="2">AC</th>
<th>low pressure</th>
<td>1.37</td>
<td>1.02</td>
<td>0.57</td>
<td>0.31</td>
<td>1.37</td>
<td>1.02</td>
<td>0.57</td>
<td>0.31</td>
<td>0.68</td>
<td>0.41</td>
<td>0.23</td>
<td>0.15</td>
</tr>
<tr>
<th>high pressure</th>
<td>1.71</td>
<td>1.17</td>
<td>0.75</td>
<td>0.37</td>
<td>1.71</td>
<td>1.17</td>
<td>0.75</td>
<td>0.37</td>
<td>0.94</td>
<td>0.75</td>
<td>0.34</td>
<td>0.29</td>
</tr>
<tr>
<th rowspan="2">DC</th>
<th>low pressure</th>
<td>1.09</td>
<td>0.78</td>
<td>0.41</td>
<td>0.16</td>
<td>1.09</td>
<td>0.78</td>
<td>0.41</td>
<td>0.16</td>
<td>0.54</td>
<td>0.34</td>
<td>0.20</td>
<td>0.078</td>
</tr>
<tr>
<th>high pressure</th>
<td>1.37</td>
<td>0.94</td>
<td>0.60</td>
<td>0.31</td>
<td>1.37</td>
<td>0.94</td>
<td>0.60</td>
<td>0.31</td>
<td>0.85</td>
<td>0.68</td>
<td>0.31</td>
<td>0.27</td>
</tr>
<tr>
<th colspan="5">Body</th>
<td colspan="12">Brass , stainless steel</td>
</tr>
<tr>
<th colspan="5">Elastomer</th>
<td colspan="12">Nitrile rubber（only NC）,Fluorine rubber（only NA,NB）,Ethylene propylene（only NA,NB）</td>
</tr>
<tr>
<th colspan="5">Poppet</th>
<td colspan="12">Polyacetal（only NC）,Stainless steel（only NA,NB）</td>
</tr>
<tr>
<th colspan="5">Housing</th>
<td colspan="12">NEMA4 drip-proof</td>
</tr>
<tr>
<th rowspan="6">Solenoid</th>
<th colspan="2" rowspan="2">Applicable voltage</th>
<th colspan="2">AC</th>
<td colspan="12">100V , 110V , 115V , 120V</td>
</tr>
<tr>
<th colspan="2">DC</th>
<td colspan="12">100V , 110V , 125V</td>
</tr>
<tr>
<th colspan="4">Allowable voltage fluctuation</th>
<td colspan="12">-15% to 10% of applicable voltage</td>
</tr>
<tr>
<th colspan="4">Insulation class</th>
<td colspan="12">Class H</td>
</tr>
<tr>
<th colspan="4">Leadwire length（mm）</th>
<td colspan="12">600</td>
</tr>
<tr>
<th colspan="4">Ambient temperature</th>
<td colspan="12">Refer to catalog for details.</td>
</tr>
<tr>
<th colspan="5">Installation position</th>
<td colspan="12">As desired（Horizontal mounting with solenoid at upper side is recommended）</td>
</tr>
<tr>
<th colspan="5">Options</th>
<td colspan="12">Mounting bracket , NPT（port） , Terminal box , operating system（only NC）</td>
</tr>
</tbody>
</table>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-na-nb-nc333-3-port-solenoid-valves-for-nuclear-power-plants-normally-closed/">KONAN NA/NB/NC333 3-port Solenoid Valves For Nuclear Power Plants Normally Closed</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN Cylinder For Controlling Oil Burners (Retractable Cylinder)</title>
		<link>https://koueitrading.com/global/product/konan-cylinder-for-controlling-oil-burners-retractable-cylinder/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Mon, 08 Mar 2021 07:32:43 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=26358</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN Model: Retractable Cylinder The retractable cylinder is mounted on the boiler in a thermal power station to be used in the automatic operation of pushing and drawing oil burners in and out. Thus, it is a very important pneumatic unit for burner control. This type of cylinder includes two [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-cylinder-for-controlling-oil-burners-retractable-cylinder/">KONAN Cylinder For Controlling Oil Burners (Retractable Cylinder)</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN<br />
Model: Retractable Cylinder</p>
<p>The retractable cylinder is mounted on the boiler in a thermal power station to be used in the automatic operation of pushing and drawing oil burners in and out. Thus, it<br />
is a very important pneumatic unit for burner control.<br />
This type of cylinder includes two types; the inner cylinder type consists of the inner cylinder and the outer cooling chamber and insulator, and the outer cylinder type<br />
in which the cylinder is placed in the outer portion.</p>
<h1>Features</h1>
<p>The insulator wall and the cooling chamber using clean air are placed in the outer portion to prevent cylinder breakage due to<br />
high temperature when the boiler is heated. (inner cylinder type)<br />
The speed controller attached to the cylinder controls the moving time for pushing and drawing the burner in and out.<br />
A locking mechanism is provided to prevent the burner from moving even when it is left for a long time as pushed in.<br />
An explosion-proof switch is appended to take.</p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-cylinder-for-controlling-oil-burners-retractable-cylinder/">KONAN Cylinder For Controlling Oil Burners (Retractable Cylinder)</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN Ball Valve For Gas Applications</title>
		<link>https://koueitrading.com/global/product/konan-ball-valve-for-gas-applications/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Mon, 08 Mar 2021 07:11:09 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=26352</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: Ball Valve The valve of this type is the ball valve for gas applications of reduced type compatible with the automation of gas burners for generator boilers and high-level denitrators and provided with good maintainability. Varieties of product lines responding to customer demands have acquired a lot [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-ball-valve-for-gas-applications/">KONAN Ball Valve For Gas Applications</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: Ball Valve</p>
<p>The valve of this type is the ball valve for gas applications of reduced type compatible with the automation of gas burners for generator boilers and high-level denitrators and provided with good maintainability.<br />
Varieties of product lines responding to customer demands have acquired a lot of delivery records domestically and overseas.</p>
<h1>Features</h1>
<p>No leak ensured by complete, sealed construction and long life without lubrication.<br />
Maintenance work requires no disassembling of piping.15A to 200A valves are the bottom entry type and 250A to 700A top entry type.<br />
Fire-safe construction.<br />
Double seal construction.<br />
No specific fluid direction.</p>
<h1>Specification</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-26354 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/03/1-5.png" alt="Ball Valve" width="853" height="272" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/1-5.png 853w, https://koueitrading.com/global/wp-content/uploads/2021/03/1-5-300x96.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/03/1-5-768x245.png 768w" sizes="auto, (max-width: 853px) 100vw, 853px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-ball-valve-for-gas-applications/">KONAN Ball Valve For Gas Applications</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN Ball Valve For High Temperature And High Pressure</title>
		<link>https://koueitrading.com/global/product/konan-ball-valve-for-high-temperature-and-high-pressure/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Mon, 08 Mar 2021 01:12:01 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=26353</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: Ball Valve The ball valve for high-temperature and high-pressure applications is particularly suitable to control fluids of high temperature and high pressure such as crude oil, heavy oil, light oil, naphtha and steam. The valve seat adopts a metal touch system, ensuring secure control-ling performance as the [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-ball-valve-for-high-temperature-and-high-pressure/">KONAN Ball Valve For High Temperature And High Pressure</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: Ball Valve</p>
<p>The ball valve for high-temperature and high-pressure applications is particularly suitable to control fluids of high temperature and high pressure such as crude oil,<br />
heavy oil, light oil, naphtha and steam.<br />
The valve seat adopts a metal touch system, ensuring secure control-ling performance as the combustion valve for automatic burners.</p>
<h1>Features</h1>
<p>● Metal touch system by precision machining and floating performance of the seat offers the perfect sealing construction.<br />
● Maintenance work requires no disassembling of piping.<br />
● Fire-safe construction.<br />
● Double seal construction.<br />
● Shocks under high pressure are prevented with a reduced flow rate in the initial stage of opening the valve, realized by small holes provided in the main port.<br />
● No specific fluid direction.<br />
● Abnormal high pressure is prevented with construction avoiding containing fluid tightly enclosed in the unit.</p>
<h1>Specification</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-26356" src="https://koueitrading.com/global/wp-content/uploads/2021/03/Capture-1.png" alt="" width="853" height="274" srcset="https://koueitrading.com/global/wp-content/uploads/2021/03/Capture-1.png 853w, https://koueitrading.com/global/wp-content/uploads/2021/03/Capture-1-300x96.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/03/Capture-1-768x247.png 768w" sizes="auto, (max-width: 853px) 100vw, 853px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-ball-valve-for-high-temperature-and-high-pressure/">KONAN Ball Valve For High Temperature And High Pressure</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN MVS2N/MVD2N Series 5-Port Solenoid Valves Pressure-resistant Packing Type</title>
		<link>https://koueitrading.com/global/product/konan-mvs2n-mvd2n-series-5-port-solenoid-valves-pressure-resistant-packing-type/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Mon, 01 Mar 2021 10:36:18 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25396</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN Model: MVS2N/MVD2N Series Specifications Return Hold Return Hold Type   Explosion-proof type   Pressure-resistant packing MVS2F-03-E2K MVS2F-03-E2E MVS2F-03-E2Y MVD2F-03-E2K MVD2F-03-E2E MVS2N-08-E2K MVS2N-08-E2E MVS2N-08-E2Y MVD2N-08-E2K MVD2N-08-E2E Conduit tube MVS2F-03-E1K MVS2F-03-E1E MVD2F-03-E1K MVD2F-03-E1E MVS2N-08-E1K MVS2N-08-E1E MVD2N-08-E1K MVD2N-08-E1E Drip-proof type MVS2F-03-E3K MVD2F-03-E3K MVS2N-08-E3K MVD2N-08-E3K Port size（Rc） 1/4・3/8・1/2 3/4・1 Effective sectional area（CV value） [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-mvs2n-mvd2n-series-5-port-solenoid-valves-pressure-resistant-packing-type/">KONAN MVS2N/MVD2N Series 5-Port Solenoid Valves Pressure-resistant Packing Type</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN<br />
Model: MVS2N/MVD2N Series</p>
<h1>Specifications</h1>
<table>
<tbody>
<tr>
<td colspan="3" width="193"></td>
<td width="123">Return</td>
<td width="123">Hold</td>
<td width="123">Return</td>
<td width="123">Hold</td>
</tr>
<tr>
<td rowspan="3" width="26">Type</td>
<td rowspan="2" width="53"><strong> </strong></p>
<p>Explosion-proof type</td>
<td width="113"><strong> </strong></p>
<p>Pressure-resistant packing</td>
<td width="123">MVS2F-03-E2K MVS2F-03-E2E MVS2F-03-E2Y</td>
<td width="123">MVD2F-03-E2K MVD2F-03-E2E</td>
<td width="123">MVS2N-08-E2K MVS2N-08-E2E MVS2N-08-E2Y</td>
<td width="123">MVD2N-08-E2K MVD2N-08-E2E</td>
</tr>
<tr>
<td width="113">Conduit tube</td>
<td width="123">MVS2F-03-E1K MVS2F-03-E1E</td>
<td width="123">MVD2F-03-E1K MVD2F-03-E1E</td>
<td width="123">MVS2N-08-E1K MVS2N-08-E1E</td>
<td width="123">MVD2N-08-E1K MVD2N-08-E1E</td>
</tr>
<tr>
<td colspan="2" width="166">Drip-proof type</td>
<td width="123">MVS2F-03-E3K</td>
<td width="123">MVD2F-03-E3K</td>
<td width="123">MVS2N-08-E3K</td>
<td width="123">MVD2N-08-E3K</td>
</tr>
<tr>
<td colspan="3" width="193">Port size（Rc）</td>
<td colspan="2" width="246">1/4・3/8・1/2</td>
<td colspan="2" width="246">3/4・1</td>
</tr>
<tr>
<td colspan="3" width="193">Effective sectional area（CV value）</td>
<td colspan="2" width="246">40㎟（2.2）・55㎟（3.0）・70㎟（3.8）</td>
<td colspan="2" width="246">175㎟（9.5）・185㎟（10.0）</td>
</tr>
<tr>
<td colspan="3" rowspan="2" width="193"><strong> </strong></p>
<p>Operating pressure</td>
<td colspan="2" width="246">0.2 〜 0.7MPa</td>
<td colspan="2" width="246">0.12 〜 0.7MPa</td>
</tr>
<tr>
<td colspan="4" width="491">In case of separate pilot supply type  Pilot operating pressure ≧ Operating pressure</td>
</tr>
<tr>
<td colspan="3" width="193">Pressure resistance</td>
<td colspan="4" width="491">1.05MPa</td>
</tr>
<tr>
<td colspan="3" width="193">Operating temperature</td>
<td colspan="2" width="246">－5〜 60℃</td>
<td colspan="2" width="246">— 20 〜 50℃</td>
</tr>
<tr>
<td colspan="3" width="193">Operating frequency</td>
<td colspan="4" width="491">1 cycle / s max.       /      1 cycle / 6 months min.</td>
</tr>
<tr>
<td colspan="3" width="193">Operation（response）time</td>
<td colspan="2" width="246">0.1 s max.</td>
<td colspan="2" width="246">0.3 s max.</td>
</tr>
<tr>
<td rowspan="7" width="26">Solenoid</td>
<td colspan="2" width="166">Rated voltage</td>
<td colspan="4" width="491">Refer to Model Code</td>
</tr>
<tr>
<td colspan="2" width="166">Voltage fluctuation tolerance</td>
<td colspan="4" width="491">— 15％〜 10％ of rated voltage</td>
</tr>
<tr>
<td colspan="2" width="166">Temperature rise</td>
<td width="123">80 deg max.</td>
<td width="123">65 deg max.</td>
<td width="123">80 deg max.</td>
<td width="123">65 deg max.</td>
</tr>
<tr>
<td colspan="2" width="166">Insulation class</td>
<td colspan="4" width="491">Class H</td>
</tr>
<tr>
<td colspan="2" width="166">Insulation resistance</td>
<td colspan="4" width="491">10MΩ min.</td>
</tr>
<tr>
<td colspan="2" width="166">Rated current</td>
<td colspan="4" width="491">Refer to Rated current data on page A-39</td>
</tr>
<tr>
<td colspan="2" width="166">Explosion-proof standard</td>
<td colspan="4" width="491">Flame-proof enclosure construction d2G4 / Exd Ⅱ BT4</td>
</tr>
<tr>
<td colspan="3" width="193">Mass</td>
<td colspan="2" width="246">Approx. 3.0kg</td>
<td colspan="2" width="246">Approx. 5.0kg</td>
</tr>
</tbody>
</table>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25382 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-74.png" alt="MVS2N/MVD2N Series " width="896" height="171" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-74.png 896w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-74-300x57.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-74-768x147.png 768w" sizes="auto, (max-width: 896px) 100vw, 896px" /></p>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25383 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-35.png" alt="MVS2N/MVD2N Series " width="922" height="631" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-35.png 922w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-35-300x205.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-35-768x526.png 768w" sizes="auto, (max-width: 922px) 100vw, 922px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-25384 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-41.png" alt="MVS2N/MVD2N Series " width="940" height="589" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-41.png 940w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-41-300x188.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-41-768x481.png 768w" sizes="auto, (max-width: 940px) 100vw, 940px" /></p>
<h1>Outside Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25397 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/2-23.png" alt="MVS2N/MVD2N Series " width="476" height="433" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/2-23.png 476w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-23-300x273.png 300w" sizes="auto, (max-width: 476px) 100vw, 476px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-25398 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/1-33.png" alt="MVS2N/MVD2N Series " width="949" height="499" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/1-33.png 949w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-33-300x158.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-33-768x404.png 768w" sizes="auto, (max-width: 949px) 100vw, 949px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-mvs2n-mvd2n-series-5-port-solenoid-valves-pressure-resistant-packing-type/">KONAN MVS2N/MVD2N Series 5-Port Solenoid Valves Pressure-resistant Packing Type</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN AVPC1/AVPO1/AVPE1 3-Position, 4-Port Air-operated Valves</title>
		<link>https://koueitrading.com/global/product/konan-avpc1-avpo1-avpe1-3-position-4-port-air-operated-valves/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Sun, 28 Feb 2021 10:54:53 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25644</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: AVPC1/AVPO1/AVPE1 Specifications Model AVP（C．O．E）1 AVP（C．O．E）2 Port size Rc3/8 Rc1/2 Rc3/4 Rc1 Rc11／4 Rc11／2 Working pressure 0.12 〜 0.7MPa Pilot pressure 0.12 〜 0.7MPa (Pilot pressure ≧ Operating pressure) Fluid temperature — 20 〜 60℃                         Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-avpc1-avpo1-avpe1-3-position-4-port-air-operated-valves/">KONAN AVPC1/AVPO1/AVPE1 3-Position, 4-Port Air-operated Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: AVPC1/AVPO1/AVPE1</p>
<h1>Specifications</h1>
<table>
<tbody>
<tr>
<td width="189">Model</td>
<td colspan="4" width="329">AVP（C．O．E）1</td>
<td colspan="2" width="164">AVP（C．O．E）2</td>
</tr>
<tr>
<td width="189">Port size</td>
<td width="82">Rc3/8</td>
<td width="82">Rc1/2</td>
<td width="82">Rc3/4</td>
<td width="82">Rc1</td>
<td width="82">Rc11<strong>／</strong>4</td>
<td width="82">Rc11<strong>／</strong>2</td>
</tr>
<tr>
<td width="189">Working pressure</td>
<td colspan="6" width="493">0.12 〜 0.7MPa</td>
</tr>
<tr>
<td width="189">Pilot pressure</td>
<td colspan="6" width="493">0.12 〜 0.7MPa (Pilot pressure ≧ Operating pressure)</td>
</tr>
<tr>
<td width="189">Fluid temperature</td>
<td colspan="6" rowspan="2" width="493">— 20 〜 60℃                         Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.</td>
</tr>
<tr>
<td width="189">Ambient temperature</td>
</tr>
<tr>
<td width="189">Effective sectional area</td>
<td width="82">35mm<sup>2</sup></td>
<td width="82">60mm<sup>2</sup></td>
<td width="82">140mm<sup>2</sup></td>
<td width="82">180mm<sup>2</sup></td>
<td width="82">250mm<sup>2</sup></td>
<td width="82">350mm<sup>2</sup></td>
</tr>
<tr>
<td width="189">Max. operating frequency</td>
<td colspan="6" width="493">1 回 /s  1 cycle /s</td>
</tr>
<tr>
<td width="189">Internal leakage</td>
<td colspan="6" width="493">JIS B 8373：2015 Less than value of the standard</td>
</tr>
<tr>
<td width="189">Installation position</td>
<td colspan="6" width="493">It is desirable to mount the valve with the spool located horizontally.</td>
</tr>
<tr>
<td width="189">Mass</td>
<td colspan="2" width="164">12kg</td>
<td colspan="2" width="164">23kg</td>
<td colspan="2" width="164">29.5kg</td>
</tr>
</tbody>
</table>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25645 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-100.png" alt="AVPC1/AVPO1/AVPE1" width="1015" height="399" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-100.png 1015w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-100-300x118.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-100-768x302.png 768w" sizes="auto, (max-width: 1015px) 100vw, 1015px" /></p>
<h1>Operation</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25646 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-64.png" alt="AVPC1/AVPO1/AVPE1" width="941" height="176" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-64.png 941w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-64-300x56.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-64-768x144.png 768w" sizes="auto, (max-width: 941px) 100vw, 941px" /></p>
<h1>External Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25648 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/2-45.png" alt="AVPC1/AVPO1/AVPE1" width="908" height="628" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/2-45.png 908w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-45-300x207.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-45-768x531.png 768w" sizes="auto, (max-width: 908px) 100vw, 908px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-avpc1-avpo1-avpe1-3-position-4-port-air-operated-valves/">KONAN AVPC1/AVPO1/AVPE1 3-Position, 4-Port Air-operated Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN Explosion-proof Solenoid Valve With Bypass Valve Conformable To NAMUR Standard (TA2 Options)</title>
		<link>https://koueitrading.com/global/product/konan-explosion-proof-solenoid-valve-with-bypass-valve-conformable-to-namur-standard-ta2-options/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Mon, 22 Feb 2021 01:19:13 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25837</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: NAMUR When placing orders with only options of actuators with options in the preceding sections and other options, use them. Assembly of the TA2 options with fitting bolts, piping joints, packing, etc. are available on request. Specifications     Model code   Return 4N4S102K － E ＊＊－ [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-explosion-proof-solenoid-valve-with-bypass-valve-conformable-to-namur-standard-ta2-options/">KONAN Explosion-proof Solenoid Valve With Bypass Valve Conformable To NAMUR Standard (TA2 Options)</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: NAMUR</p>
<p><strong>When placing orders with only options of actuators with options in the preceding sections and other options, use them.</strong></p>
<p><strong>Assembly of the TA2 options with fitting bolts, piping joints, packing, etc. are available on request.</strong></p>
<h1>Specifications</h1>
<table>
<tbody>
<tr>
<td colspan="2" rowspan="2" width="93"><strong> </strong></p>
<p><strong> </strong></p>
<p>Model code</td>
<td width="71"><strong> </strong></p>
<p>Return</td>
<td width="518">4N4S102K － E ＊＊－ H ＊＊－＊</p>
<p>4N4S10BK － E ＊＊－ H ＊＊－＊</p>
<p>4N4S102K － P ＊＊－ H ＊＊－＊</p>
<p>4N4S10BK － P ＊＊－ H ＊＊－＊</td>
</tr>
<tr>
<td width="71"><strong> </strong></p>
<p>Hold</td>
<td width="518">4N4D102K － E ＊＊－ H ＊＊－＊</p>
<p>4N4D10BK － E ＊＊－ H ＊＊－＊</p>
<p>4N4D102K － P ＊＊－ H ＊＊－＊</p>
<p>4N4D10BK － P ＊＊－ H ＊＊－＊</td>
</tr>
<tr>
<td colspan="3" width="165">Operating fluid</td>
<td width="518">Compressed air</td>
</tr>
<tr>
<td colspan="3" width="165">Operating pressure</td>
<td width="518">0.15 〜 0.7MPa</td>
</tr>
<tr>
<td colspan="3" width="165">Ambient temperature</td>
<td width="518">－5〜 60℃</td>
</tr>
<tr>
<td colspan="3" width="165">Fluid temperature</td>
<td width="518">－5〜 60℃</p>
<p>（In case of － 5℃ to ＋ 5℃ , ensure to be removed any water contained for prevention of freezing.）</td>
</tr>
<tr>
<td colspan="3" width="165">Operation frequency</td>
<td width="518">Max.：twice /second     Min.：once /six months</td>
</tr>
<tr>
<td colspan="3" width="165">Lubricating</td>
<td width="518">Not necessary</td>
</tr>
<tr>
<td colspan="3" width="165">Mass</td>
<td width="518">Please refer to Page 98.</td>
</tr>
<tr>
<td colspan="3" width="165">Protective class</td>
<td width="518">IP65</td>
</tr>
<tr>
<td rowspan="4" width="47">Valve section</td>
<td colspan="2" width="117">The effective area of the valve</td>
<td width="518">Over 10㎟（for a single solenoid valve without a silencer and throttle valve）</td>
</tr>
<tr>
<td colspan="2" width="117">Response time</td>
<td width="518">Less than 0.05 s</td>
</tr>
<tr>
<td colspan="2" width="117">Allowable air leakage</td>
<td width="518">Below is the value provided for JIS B8375 － 1993</td>
</tr>
<tr>
<td colspan="2" width="117">Proof pressure</td>
<td width="518">1.2MPa</td>
</tr>
<tr>
<td rowspan="9" width="47">Solenoid section</td>
<td colspan="2" width="117">Explosion-proof construction</td>
<td width="518">d2G4 Pressure-resistance explosion-proof construction</td>
</tr>
<tr>
<td colspan="2" width="117">Rating</td>
<td width="518">Continuous rating</td>
</tr>
<tr>
<td colspan="2" width="117">Voltage tolerance</td>
<td width="518">— 15％〜 10％ of the rated voltage</td>
</tr>
<tr>
<td colspan="2" width="117">Apparent power（AC）</td>
<td width="518">Energized less than 7.5VA（50Hz）and 5.5VA（60Hz）, starting current less than 3 times to the energized power.</td>
</tr>
<tr>
<td colspan="2" width="117">Power consumption（DC）</td>
<td width="518">Below 4W</td>
</tr>
<tr>
<td colspan="2" width="117">Type of insulation</td>
<td width="518">JIS  C4003  Type H</td>
</tr>
<tr>
<td colspan="2" width="117">Temperature increase</td>
<td width="518">Less than 70℃（Resistance method）</td>
</tr>
<tr>
<td colspan="2" width="117">Insulation resistance</td>
<td width="518">Less than 10MΩ（DC500V megger）</td>
</tr>
<tr>
<td colspan="2" width="117">Voltage proof</td>
<td width="518">AC1500V（for one minute）</td>
</tr>
<tr>
<td rowspan="2" width="47">Silencer (with throttle</td>
<td colspan="2" width="117">Model code</td>
<td width="518">EVS5 － 6A</td>
</tr>
<tr>
<td colspan="2" width="117">Sound-absorbing effect</td>
<td width="518">More than 15dB</td>
</tr>
</tbody>
</table>
<h1><strong>Model Code</strong></h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25838 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/1-88.png" alt="KONAN" width="760" height="143" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/1-88.png 760w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-88-300x56.png 300w" sizes="auto, (max-width: 760px) 100vw, 760px" /><img loading="lazy" decoding="async" class="alignnone wp-image-25839 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/2-70.png" alt="KONAN" width="936" height="589" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/2-70.png 936w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-70-300x189.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-70-768x483.png 768w" sizes="auto, (max-width: 936px) 100vw, 936px" /><img loading="lazy" decoding="async" class="alignnone wp-image-25840 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/3-37.png" alt="NAMUR " width="718" height="180" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/3-37.png 718w, https://koueitrading.com/global/wp-content/uploads/2021/02/3-37-300x75.png 300w" sizes="auto, (max-width: 718px) 100vw, 718px" /><img loading="lazy" decoding="async" class="alignnone wp-image-25841 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/4-28.png" alt="KONAN" width="960" height="588" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/4-28.png 960w, https://koueitrading.com/global/wp-content/uploads/2021/02/4-28-300x184.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/4-28-768x470.png 768w" sizes="auto, (max-width: 960px) 100vw, 960px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-explosion-proof-solenoid-valve-with-bypass-valve-conformable-to-namur-standard-ta2-options/">KONAN Explosion-proof Solenoid Valve With Bypass Valve Conformable To NAMUR Standard (TA2 Options)</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN NAMUR Standard 5-port Solenoid Valve With Bypass Valve (TA2 Options)</title>
		<link>https://koueitrading.com/global/product/konan-namur-standard-5-port-solenoid-valve-with-bypass-valve-ta2-options/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Sun, 21 Feb 2021 12:11:42 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25833</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: NAMUR When placing orders with only options of actuators with options in the preceding sections and other options, use them. Assembly of the TA2 options with fitting bolts, piping joints, packing, etc. are available on request. Specifications   Model code Return 4N3S102K 4N3S10BK Hold 4N3D102K 4N3D10BK Operating [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-namur-standard-5-port-solenoid-valve-with-bypass-valve-ta2-options/">KONAN NAMUR Standard 5-port Solenoid Valve With Bypass Valve (TA2 Options)</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: NAMUR</p>
<p><strong>When placing orders with only options of actuators with options in the preceding sections and other options, use them.</strong></p>
<p><strong>Assembly of the TA2 options with fitting bolts, piping joints, packing, etc. are available on request.</strong></p>
<h1>Specifications</h1>
<table>
<tbody>
<tr>
<td colspan="2" rowspan="2" width="89"><strong> </strong></p>
<p>Model code</td>
<td width="64">Return</td>
<td width="529">4N3S102K</p>
<p>4N3S10BK</td>
</tr>
<tr>
<td width="64">Hold</td>
<td width="529">4N3D102K</p>
<p>4N3D10BK</td>
</tr>
<tr>
<td colspan="3" width="153">Operating fluid</td>
<td width="529">Compressed air</td>
</tr>
<tr>
<td colspan="3" width="153">Operating pressure</td>
<td width="529">0.2 〜 0.7MPa</td>
</tr>
<tr>
<td colspan="3" width="153">Ambient temperature</td>
<td width="529">－5〜 50℃</td>
</tr>
<tr>
<td colspan="3" width="153">Fluid temperature</td>
<td width="529">－5〜 50℃</p>
<p>（In case of － 5℃ to ＋ 5℃ , ensure to be removed any water contained for prevention of freezing.）</td>
</tr>
<tr>
<td colspan="3" width="153">Operation Frequency</td>
<td width="529">Max.：four times / second      Min.：once / month</td>
</tr>
<tr>
<td colspan="3" width="153">Voltage tolerance</td>
<td width="529">± 10％ of the rated voltage</td>
</tr>
<tr>
<td colspan="3" width="153">Lubricating</td>
<td width="529">Not necessary</td>
</tr>
<tr>
<td colspan="3" width="153">Mass</td>
<td width="529">Please refer to Page 98.</td>
</tr>
<tr>
<td colspan="3" width="153">Protection class</td>
<td width="529">Wiring type         L：IP41       D, N：IP54       W：IP55</td>
</tr>
<tr>
<td rowspan="4" width="47">Valve section</td>
<td colspan="2" width="106">The effective area of the  valve</td>
<td width="529">Over 10㎟（for a single solenoid valve without silencer and throttle valve）</td>
</tr>
<tr>
<td colspan="2" width="106">Response time</td>
<td width="529">Less than 0.03 s</td>
</tr>
<tr>
<td colspan="2" width="106">Allowable air leakage</td>
<td width="529">Less than the value provided for in JIS B8375 － 1993</td>
</tr>
<tr>
<td colspan="2" width="106">Proof pressure</td>
<td width="529">1.2MPa</td>
</tr>
<tr>
<td rowspan="5" width="47">Solenoid section</td>
<td colspan="2" width="106">Type of insulation</td>
<td width="529">JIS  C4003  Type B</td>
</tr>
<tr>
<td colspan="2" width="106">Temperature increase</td>
<td width="529">Less than 70℃（Resistance method）</td>
</tr>
<tr>
<td colspan="2" width="106">Insulation resistance</td>
<td width="529">Over 100MΩ（measured by the 500V insulation resistance method）</td>
</tr>
<tr>
<td colspan="2" width="106">Voltage proof</td>
<td width="529">AC1500V（for one minute）</td>
</tr>
<tr>
<td colspan="2" width="106">Power consumption</td>
<td width="529">AC：6VA       DC：5.5W</td>
</tr>
<tr>
<td rowspan="2" width="47">Silencer (with throttle</td>
<td colspan="2" width="106">Model code</td>
<td width="529">EVS5 － 6A</td>
</tr>
<tr>
<td colspan="2" width="106">Sound-absorbing effect</td>
<td width="529">More than 15dB</td>
</tr>
</tbody>
</table>
<h1><strong>Model Code</strong></h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25834 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-77.png" alt="NAMUR" width="943" height="804" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-77.png 943w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-77-300x256.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-77-768x655.png 768w" sizes="auto, (max-width: 943px) 100vw, 943px" /></p>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25835 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-52.png" alt="NAMUR" width="949" height="587" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-52.png 949w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-52-300x186.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-52-768x475.png 768w" sizes="auto, (max-width: 949px) 100vw, 949px" /></p>
<hr />
<ul>
<li>Kouei is the Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-namur-standard-5-port-solenoid-valve-with-bypass-valve-ta2-options/">KONAN NAMUR Standard 5-port Solenoid Valve With Bypass Valve (TA2 Options)</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN AVS2 2-Position, 5-Port Air-operated Valves</title>
		<link>https://koueitrading.com/global/product/konan-avs2-2-position-5-port-air-operated-valves/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Fri, 19 Feb 2021 14:00:24 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25629</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: AVS2 Specifications Model AVS2 Port size Rc3/8 Rc1/2 Rc3/4 Rc1 Working pressure 0.12 〜 0.7MPa Pilot pressure 0.12 〜 0.7MPa (Pilot pressure ≧ Operating pressure) Fluid temperature — 20 〜 60℃                    Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower. Ambient [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-avs2-2-position-5-port-air-operated-valves/">KONAN AVS2 2-Position, 5-Port Air-operated Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: AVS2</p>
<h1>Specifications</h1>
<table>
<tbody>
<tr>
<td width="187">Model</td>
<td colspan="4" width="499">AVS2</td>
</tr>
<tr>
<td width="187">Port size</td>
<td width="125">Rc3/8</td>
<td width="125">Rc1/2</td>
<td width="125">Rc3/4</td>
<td width="125">Rc1</td>
</tr>
<tr>
<td width="187">Working pressure</td>
<td colspan="4" width="499">0.12 〜 0.7MPa</td>
</tr>
<tr>
<td width="187">Pilot pressure</td>
<td colspan="4" width="499">0.12 〜 0.7MPa</p>
<p>(Pilot pressure ≧ Operating pressure)</td>
</tr>
<tr>
<td width="187">Fluid temperature</td>
<td colspan="4" rowspan="2" width="499">— 20 〜 60℃                    Remove moisture perfectly from the fluid to prevent freezing when used</p>
<p>at 5℃ or lower.</td>
</tr>
<tr>
<td width="187">Ambient temperature</td>
</tr>
<tr>
<td width="187">Effective sectional area</td>
<td width="125">60mm<sup>2</sup></td>
<td width="125">70mm<sup>2</sup></td>
<td width="125">150mm<sup>2</sup></td>
<td width="125">165mm<sup>2</sup></td>
</tr>
<tr>
<td width="187">Max. operating frequency</td>
<td colspan="4" width="499">1 回 /s  1 cycle /s</td>
</tr>
<tr>
<td width="187">Internal leakage</td>
<td colspan="4" width="499">JIS B 8373：2015 Less than value of the standard</td>
</tr>
<tr>
<td width="187">Installation position</td>
<td colspan="4" width="499">It is desirable to mount the valve with the spool located horizontally.</td>
</tr>
<tr>
<td width="187">Mass</td>
<td colspan="2" width="249">2.0kg</td>
<td colspan="2" width="249">4.5kg</td>
</tr>
</tbody>
</table>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25631 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-98.png" alt="AVS2" width="341" height="265" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-98.png 341w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-98-300x233.png 300w" sizes="auto, (max-width: 341px) 100vw, 341px" /></p>
<h1>Operation</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25632 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-62.png" alt="AVS2" width="999" height="329" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-62.png 999w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-62-300x99.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-62-768x253.png 768w" sizes="auto, (max-width: 999px) 100vw, 999px" /></p>
<h1>External Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25633 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/2-43.png" alt="AVS2" width="741" height="539" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/2-43.png 741w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-43-300x218.png 300w" sizes="auto, (max-width: 741px) 100vw, 741px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-25634 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/1-62.png" alt="AVS2" width="658" height="460" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/1-62.png 658w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-62-300x210.png 300w" sizes="auto, (max-width: 658px) 100vw, 658px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-avs2-2-position-5-port-air-operated-valves/">KONAN AVS2 2-Position, 5-Port Air-operated Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN AVS150C 2-Position, 4-Port Air-operated Valves</title>
		<link>https://koueitrading.com/global/product/konan-avs150c-2-position-4-port-air-operated-valves/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Fri, 19 Feb 2021 13:53:19 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25642</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: AVS150C Specifications Model AVS120C AVS150C Port size Rc11／4 Rc11／2 Working pressure 0.2 〜 0.7MPa Pilot pressure 0.2 〜 0.7MPa (Pilot pressure ≧ Operating pressure) Fluid temperature — 20 〜 60℃                  Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower. Ambient temperature [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-avs150c-2-position-4-port-air-operated-valves/">KONAN AVS150C 2-Position, 4-Port Air-operated Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: AVS150C</p>
<h1>Specifications</h1>
<table>
<tbody>
<tr>
<td style="text-align: center;" width="189">M<strong>odel</strong></td>
<td style="text-align: center;" width="246"><strong>AVS120C</strong></td>
<td style="text-align: center;" width="246"><strong>AVS150C</strong></td>
</tr>
<tr>
<td width="189"><strong>Port size</strong></td>
<td style="text-align: center;" width="246">Rc11<strong>／</strong>4</td>
<td style="text-align: center;" width="246">Rc11<strong>／</strong>2</td>
</tr>
<tr>
<td width="189"><strong>Working pressure</strong></td>
<td style="text-align: center;" colspan="2" width="493">0.2 〜 0.7MPa</td>
</tr>
<tr>
<td width="189"><strong>Pilot pressure</strong></td>
<td colspan="2" width="493">
<p style="text-align: center;">0.2 〜 0.7MPa</p>
<p style="text-align: center;">(Pilot pressure ≧ Operating pressure)</p>
</td>
</tr>
<tr>
<td width="189"><strong>Fluid temperature</strong></td>
<td style="text-align: center;" colspan="2" rowspan="2" width="493">— 20 〜 60℃                  Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.</td>
</tr>
<tr>
<td width="189"><strong>Ambient temperature</strong></td>
</tr>
<tr>
<td width="189"><strong>Effective sectional area</strong></td>
<td style="text-align: center;" width="246">250mm<sup>2</sup></td>
<td style="text-align: center;" width="246">300mm<sup>2</sup></td>
</tr>
<tr>
<td width="189"><strong>Max. operating frequency</strong></td>
<td style="text-align: center;" colspan="2" width="493">1 回 /s  1 cycle /s</td>
</tr>
<tr>
<td width="189"><strong>Internal leakage</strong></td>
<td style="text-align: center;" colspan="2" width="493">JIS B 8373：2015 Less than value of the standard</td>
</tr>
<tr>
<td width="189"><strong>Installation position</strong></td>
<td style="text-align: center;" colspan="2" width="493">It is desirable to mount the valve with the spool located horizontally.</td>
</tr>
<tr>
<td width="189"><strong>Mass</strong></td>
<td style="text-align: center;" width="246">16kg</td>
<td style="text-align: center;" width="246">19kg</td>
</tr>
</tbody>
</table>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="wp-image-25637 size-full aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-99.png" alt="AVS150C" width="736" height="257" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-99.png 736w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-99-300x105.png 300w" sizes="auto, (max-width: 736px) 100vw, 736px" /></p>
<h1>Operation</h1>
<p><img loading="lazy" decoding="async" class="wp-image-25638 size-full aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-63.png" alt="AVS150C" width="1001" height="329" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-63.png 1001w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-63-300x99.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-63-768x252.png 768w" sizes="auto, (max-width: 1001px) 100vw, 1001px" /></p>
<h1>External Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-25639" src="https://koueitrading.com/global/wp-content/uploads/2021/02/2-44.png" alt="" width="525" height="102" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/2-44.png 525w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-44-300x58.png 300w" sizes="auto, (max-width: 525px) 100vw, 525px" /> <img loading="lazy" decoding="async" class="wp-image-25640 size-full aligncenter" src="https://koueitrading.com/global/wp-content/uploads/2021/02/1-63.png" alt="AVS150C" width="873" height="746" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/1-63.png 873w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-63-300x256.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-63-768x656.png 768w" sizes="auto, (max-width: 873px) 100vw, 873px" /></p>
<hr />
<p>Kouei is Distributor/Agent of <b>KONAN.</b></p>
<p><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></p>
<p><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></p>
<div id="gtx-trans" style="position: absolute; left: 56px; top: 88.6px;">
<div class="gtx-trans-icon"></div>
</div>The post <a href="https://koueitrading.com/global/product/konan-avs150c-2-position-4-port-air-operated-valves/">KONAN AVS150C 2-Position, 4-Port Air-operated Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN AVW7(R) 2-Position, 3-Port Air-operated Valves</title>
		<link>https://koueitrading.com/global/product/konan-avw7r-2-position-3-port-air-operated-valves/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Fri, 19 Feb 2021 13:15:09 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25620</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: AVW7(R) Specifications Model AVW71（R） AVW7（R） Port size Rc3/8 Rc1/2 Rc3/4 Rc1 Working pressure 0 〜 0.7MPa Pilot pressure 0.3 〜 0.7MPa (Pilot pressure ≧ Operating pressure) Fluid temperature — 20 〜 60℃                  Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower. [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-avw7r-2-position-3-port-air-operated-valves/">KONAN AVW7(R) 2-Position, 3-Port Air-operated Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: AVW7(R)</p>
<h1>Specifications</h1>
<table>
<tbody>
<tr>
<td width="189">Model</td>
<td colspan="2" width="247">AVW71（R）</td>
<td colspan="2" width="247">AVW7（R）</td>
</tr>
<tr>
<td width="189">Port size</td>
<td width="123">Rc3/8</td>
<td width="123">Rc1/2</td>
<td width="123">Rc3/4</td>
<td width="123">Rc1</td>
</tr>
<tr>
<td width="189">Working pressure</td>
<td colspan="4" width="493">0 〜 0.7MPa</td>
</tr>
<tr>
<td width="189">Pilot pressure</td>
<td colspan="4" width="493">0.3 〜 0.7MPa</p>
<p>(Pilot pressure ≧ Operating pressure)</td>
</tr>
<tr>
<td width="189">Fluid temperature</td>
<td colspan="4" rowspan="2" width="493">— 20 〜 60℃                  Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.</td>
</tr>
<tr>
<td width="189">Ambient temperature</td>
</tr>
<tr>
<td width="189">Effective sectional area</td>
<td width="123">65mm<sup>2</sup></td>
<td width="123">75mm<sup>2</sup></td>
<td width="123">160mm<sup>2</sup></td>
<td width="123">190mm<sup>2</sup></td>
</tr>
<tr>
<td width="189">Max. operating frequency</td>
<td colspan="4" width="493">1 回 /s  1 cycle /s</td>
</tr>
<tr>
<td width="189">Internal leakage</td>
<td colspan="4" width="493">JIS B 8373：2015 Less than value of the standard</td>
</tr>
<tr>
<td width="189">Installation position</td>
<td colspan="4" width="493">Free</td>
</tr>
<tr>
<td width="189">Mass</td>
<td colspan="2" width="247">1.0kg</td>
<td colspan="2" width="247">2.5kg</td>
</tr>
</tbody>
</table>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25616 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-96.png" alt="AVW7(R) " width="1010" height="322" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-96.png 1010w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-96-300x96.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-96-768x245.png 768w" sizes="auto, (max-width: 1010px) 100vw, 1010px" /></p>
<h1>Operation</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-25617" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-60.png" alt="" width="990" height="327" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-60.png 990w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-60-300x99.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-60-768x254.png 768w" sizes="auto, (max-width: 990px) 100vw, 990px" /></p>
<h1>External Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25618 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/1-60.png" alt="AVW7(R) " width="931" height="705" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/1-60.png 931w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-60-300x227.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-60-768x582.png 768w" sizes="auto, (max-width: 931px) 100vw, 931px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-avw7r-2-position-3-port-air-operated-valves/">KONAN AVW7(R) 2-Position, 3-Port Air-operated Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN AVPC2/AVPO2/AVPE2 3-Position, 4-Port Air-operated Valves</title>
		<link>https://koueitrading.com/global/product/konan-avpc2-avpo2-avpe2-3-position-4-port-air-operated-valves/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Fri, 19 Feb 2021 13:02:00 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25650</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: AVPC2/AVPO2/AVPE2 Specifications Model AVP（C．O．E）1 AVP（C．O．E）2 Port size Rc3/8 Rc1/2 Rc3/4 Rc1 Rc11／4 Rc11／2 Working pressure 0.12 〜 0.7MPa Pilot pressure 0.12 〜 0.7MPa (Pilot pressure ≧ Operating pressure) Fluid temperature — 20 〜 60℃                         Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-avpc2-avpo2-avpe2-3-position-4-port-air-operated-valves/">KONAN AVPC2/AVPO2/AVPE2 3-Position, 4-Port Air-operated Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: AVPC2/AVPO2/AVPE2</p>
<h1>Specifications</h1>
<table>
<tbody>
<tr>
<td width="189">Model</td>
<td colspan="4" width="329">AVP（C．O．E）1</td>
<td colspan="2" width="164">AVP（C．O．E）2</td>
</tr>
<tr>
<td width="189">Port size</td>
<td width="82">Rc3/8</td>
<td width="82">Rc1/2</td>
<td width="82">Rc3/4</td>
<td width="82">Rc1</td>
<td width="82">Rc11<strong>／</strong>4</td>
<td width="82">Rc11<strong>／</strong>2</td>
</tr>
<tr>
<td width="189">Working pressure</td>
<td colspan="6" width="493">0.12 〜 0.7MPa</td>
</tr>
<tr>
<td width="189">Pilot pressure</td>
<td colspan="6" width="493">0.12 〜 0.7MPa (Pilot pressure ≧ Operating pressure)</td>
</tr>
<tr>
<td width="189">Fluid temperature</td>
<td colspan="6" rowspan="2" width="493">— 20 〜 60℃                         Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.</td>
</tr>
<tr>
<td width="189">Ambient temperature</td>
</tr>
<tr>
<td width="189">Effective sectional area</td>
<td width="82">35mm<sup>2</sup></td>
<td width="82">60mm<sup>2</sup></td>
<td width="82">140mm<sup>2</sup></td>
<td width="82">180mm<sup>2</sup></td>
<td width="82">250mm<sup>2</sup></td>
<td width="82">350mm<sup>2</sup></td>
</tr>
<tr>
<td width="189">Max. operating frequency</td>
<td colspan="6" width="493">1 回 /s  1 cycle /s</td>
</tr>
<tr>
<td width="189">Internal leakage</td>
<td colspan="6" width="493">JIS B 8373：2015 Less than the value of the standard</td>
</tr>
<tr>
<td width="189">Installation position</td>
<td colspan="6" width="493">It is desirable to mount the valve with the spool located horizontally.</td>
</tr>
<tr>
<td width="189">Mass</td>
<td colspan="2" width="164">12kg</td>
<td colspan="2" width="164">23kg</td>
<td colspan="2" width="164">29.5kg</td>
</tr>
</tbody>
</table>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25645 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-100.png" alt="AVPC2/AVPO2/AVPE2" width="1015" height="399" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-100.png 1015w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-100-300x118.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-100-768x302.png 768w" sizes="auto, (max-width: 1015px) 100vw, 1015px" /></p>
<h1>Operation</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25651 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/1-64.png" alt="AVPC2/AVPO2/AVPE2" width="939" height="179" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/1-64.png 939w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-64-300x57.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-64-768x146.png 768w" sizes="auto, (max-width: 939px) 100vw, 939px" /></p>
<h1>External Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25648 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/2-45.png" alt="AVPC2/AVPO2/AVPE2" width="908" height="628" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/2-45.png 908w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-45-300x207.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-45-768x531.png 768w" sizes="auto, (max-width: 908px) 100vw, 908px" /></p>
<hr />
<ul>
<li>Kouei is the Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-avpc2-avpo2-avpe2-3-position-4-port-air-operated-valves/">KONAN AVPC2/AVPO2/AVPE2 3-Position, 4-Port Air-operated Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN MVPC2/MVPO2/MVPE2 3-Position, 4-Port Solenoid Valves</title>
		<link>https://koueitrading.com/global/product/konan-mvpc2-mvpo2-mvpe2-3-position-4-port-solenoid-valves/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Fri, 19 Feb 2021 11:59:17 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25603</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: MVPC2/MVPO2/MVPE2 Specifications Model MVP（C．O．E）1 MVP（C．O．E）2 Port size Rc3/8 Rc1/2 Rc3/4 Rc1 Rc11／4 Rc11／2 Working pressure 0.12 〜 0.7MPa Fluid temperature — 20 〜 60℃ Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower. Ambient temperature — 20 〜 50℃ Effective sectional [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-mvpc2-mvpo2-mvpe2-3-position-4-port-solenoid-valves/">KONAN MVPC2/MVPO2/MVPE2 3-Position, 4-Port Solenoid Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: MVPC2/MVPO2/MVPE2</p>
<h1>Specifications</h1>
<table>
<tbody>
<tr>
<td colspan="2" width="189">Model</td>
<td colspan="6" width="329">MVP（C．O．E）1</td>
<td colspan="3" width="164">MVP（C．O．E）2</td>
</tr>
<tr>
<td colspan="2" width="189">Port size</td>
<td width="82">Rc3/8</td>
<td colspan="2" width="82">Rc1/2</td>
<td colspan="2" width="82">Rc3/4</td>
<td width="82">Rc1</td>
<td width="82">Rc11<strong>／</strong>4</td>
<td colspan="2" width="82">Rc11<strong>／</strong>2</td>
</tr>
<tr>
<td colspan="2" width="189">Working pressure</td>
<td colspan="9" width="493">0.12 〜 0.7MPa</td>
</tr>
<tr>
<td colspan="2" width="189">Fluid temperature</td>
<td colspan="4" width="198">— 20 〜 60℃</td>
<td colspan="5" rowspan="2" width="295">Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.</td>
</tr>
<tr>
<td colspan="2" width="189">Ambient temperature</td>
<td colspan="4" width="198">— 20 〜 50℃</td>
</tr>
<tr>
<td colspan="2" width="189">Effective sectional area</td>
<td width="82">35mm<sup>2</sup></td>
<td colspan="2" width="82">60mm<sup>2</sup></td>
<td colspan="2" width="82">140mm<sup>2</sup></td>
<td width="82">180mm<sup>2</sup></td>
<td width="82">250mm<sup>2</sup></td>
<td colspan="2" width="82">350mm<sup>2</sup></td>
</tr>
<tr>
<td rowspan="2" width="102">Response timearea</td>
<td width="87">AC</td>
<td colspan="2" width="93">0.3s 以下</td>
<td width="72">≦ 0.3 s</td>
<td colspan="3" width="164">0.4s 以 下 ≦ 0.4 s</td>
<td colspan="2" width="92">0.5s 以下</td>
<td width="72">≦ 0.5 s</td>
</tr>
<tr>
<td width="87">DC</td>
<td colspan="2" width="93">0.4s 以下</td>
<td width="72">≦ 0.4 s</td>
<td colspan="3" width="164">0.52s 以下 ≦ 0.52 s</td>
<td colspan="2" width="92">0.5s 以下</td>
<td width="72">≦ 0.5 s</td>
</tr>
<tr>
<td colspan="2" width="189">Max. operating frequency</td>
<td colspan="9" width="493">1 回 /s  1 cycle /s</td>
</tr>
<tr>
<td colspan="2" width="189">Internal leakage</td>
<td colspan="9" width="493">JIS B 8373：2015 Less than value of the standard</td>
</tr>
<tr>
<td colspan="2" width="189">&nbsp;</p>
<p>Installation position</td>
<td colspan="9" width="493">It is desirable to mount the valve with the spool located horizontally.</td>
</tr>
<tr>
<td colspan="2" width="189">Mass</td>
<td colspan="3" width="164">13.5kg</td>
<td colspan="3" width="164">25.0kg</td>
<td colspan="3" width="164">31.5kg</td>
</tr>
</tbody>
</table>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25592 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-94.png" alt="MVPC2/MVPO2/MVPE2" width="1003" height="846" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-94.png 1003w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-94-300x253.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-94-768x648.png 768w" sizes="auto, (max-width: 1003px) 100vw, 1003px" /></p>
<h1>Operation</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25593 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-58.png" alt="MVPC2/MVPO2/MVPE2" width="939" height="398" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-58.png 939w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-58-300x127.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-58-768x326.png 768w" sizes="auto, (max-width: 939px) 100vw, 939px" /></p>
<p>&nbsp;</p>
<h1>External Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25604 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/1-58.png" alt="MVPC2/MVPO2/MVPE2" width="771" height="522" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/1-58.png 771w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-58-300x203.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-58-768x520.png 768w" sizes="auto, (max-width: 771px) 100vw, 771px" /></p>
<h1>Parts</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25598 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/7.png" alt="MVPC2/MVPO2/MVPE2" width="479" height="419" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/7.png 479w, https://koueitrading.com/global/wp-content/uploads/2021/02/7-300x262.png 300w" sizes="auto, (max-width: 479px) 100vw, 479px" /> <img loading="lazy" decoding="async" class="alignnone size-full wp-image-25599" src="https://koueitrading.com/global/wp-content/uploads/2021/02/5-4.png" alt="" width="482" height="458" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/5-4.png 482w, https://koueitrading.com/global/wp-content/uploads/2021/02/5-4-300x285.png 300w" sizes="auto, (max-width: 482px) 100vw, 482px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-25600 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/6.png" alt="MVPC2/MVPO2/MVPE2" width="471" height="833" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/6.png 471w, https://koueitrading.com/global/wp-content/uploads/2021/02/6-170x300.png 170w" sizes="auto, (max-width: 471px) 100vw, 471px" /></p>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25605 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/2-40.png" alt="MVPC2/MVPO2/MVPE2" width="478" height="188" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/2-40.png 478w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-40-300x118.png 300w" sizes="auto, (max-width: 478px) 100vw, 478px" /></p>
<h1>Structure</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25594 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/2-39.png" alt="MVPC2/MVPO2/MVPE2" width="955" height="810" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/2-39.png 955w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-39-300x254.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-39-768x651.png 768w" sizes="auto, (max-width: 955px) 100vw, 955px" /> <img loading="lazy" decoding="async" class="alignnone size-full wp-image-25595" src="https://koueitrading.com/global/wp-content/uploads/2021/02/1-57.png" alt="" width="694" height="498" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/1-57.png 694w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-57-300x215.png 300w" sizes="auto, (max-width: 694px) 100vw, 694px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>
<div id="gtx-trans" style="position: absolute; left: -40px; top: -10px;">
<div class="gtx-trans-icon"></div>
</div>The post <a href="https://koueitrading.com/global/product/konan-mvpc2-mvpo2-mvpe2-3-position-4-port-solenoid-valves/">KONAN MVPC2/MVPO2/MVPE2 3-Position, 4-Port Solenoid Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN AVW5A(R) 2-Position, 3-Port Air-operated Valves</title>
		<link>https://koueitrading.com/global/product/konan-avw5ar-2-position-3-port-air-operated-valves/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Fri, 19 Feb 2021 11:15:16 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25622</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: AVW5A(R) Specifications Model AVW5A（R） Port size Rc1/4/8 Rc11／2 Rc2 Working pressure 0.15 〜 0.7MPa Pilot pressure 0.15 〜 0.7MPa (Pilot pressure ≧ Operating pressure) Fluid temperature — 20 〜 60℃               used Remove moisture perfectly from the fluid to prevent freezing when at 5℃ or lower. Ambient temperature [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-avw5ar-2-position-3-port-air-operated-valves/">KONAN AVW5A(R) 2-Position, 3-Port Air-operated Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: AVW5A(R)</p>
<h1>Specifications</h1>
<table>
<tbody>
<tr>
<td width="189">Model</td>
<td colspan="3" width="495">AVW5A（R）</td>
</tr>
<tr>
<td width="189">Port size</td>
<td width="165">Rc1/4/8</td>
<td width="165">Rc11<strong>／</strong>2</td>
<td width="165">Rc2</td>
</tr>
<tr>
<td width="189">Working pressure</td>
<td colspan="3" width="495">0.15 〜 0.7MPa</td>
</tr>
<tr>
<td width="189">Pilot pressure</td>
<td colspan="3" width="495">0.15 〜 0.7MPa (Pilot pressure ≧ Operating pressure)</td>
</tr>
<tr>
<td width="189">Fluid temperature</td>
<td colspan="3" rowspan="2" width="495">— 20 〜 60℃               used</p>
<p>Remove moisture perfectly from the fluid to prevent freezing when at 5℃ or lower.</td>
</tr>
<tr>
<td width="189">Ambient temperature</td>
</tr>
<tr>
<td width="189">Effective sectional area</td>
<td width="165">350mm<sup>2</sup></td>
<td width="165">800mm<sup>2</sup></td>
<td width="165">800mm<sup>2</sup></td>
</tr>
<tr>
<td width="189">Max. operating frequency</td>
<td colspan="3" width="495">1 回 /s  1 cycle /s</td>
</tr>
<tr>
<td width="189">Internal leakage</td>
<td colspan="3" width="495">JIS B 8373：2015 Less than value of the standard</td>
</tr>
<tr>
<td width="189">Installation position</td>
<td colspan="3" width="495">Free</td>
</tr>
<tr>
<td width="189">Mass</td>
<td width="165">8kg</td>
<td colspan="2" width="330">10.0kg</td>
</tr>
</tbody>
</table>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25623 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-97.png" alt="AVW5A(R)" width="765" height="314" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-97.png 765w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-97-300x123.png 300w" sizes="auto, (max-width: 765px) 100vw, 765px" /></p>
<h1>Operation</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25624 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-61.png" alt="AVW5A(R)" width="941" height="268" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-61.png 941w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-61-300x85.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-61-768x219.png 768w" sizes="auto, (max-width: 941px) 100vw, 941px" /></p>
<h1>External Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25625 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/2-42.png" alt="AVW5A(R)" width="892" height="594" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/2-42.png 892w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-42-300x200.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-42-768x511.png 768w" sizes="auto, (max-width: 892px) 100vw, 892px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-25626 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/1-61.png" alt="AVW5A(R)" width="898" height="552" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/1-61.png 898w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-61-300x184.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-61-768x472.png 768w" sizes="auto, (max-width: 898px) 100vw, 898px" /></p>
<hr />
<ul>
<li>Kouei is the Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-avw5ar-2-position-3-port-air-operated-valves/">KONAN AVW5A(R) 2-Position, 3-Port Air-operated Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN AVW12(R) 2-Position, 2-Port Air-operated Valves</title>
		<link>https://koueitrading.com/global/product/konan-avw12r-2-position-2-port-air-operated-valves/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Fri, 19 Feb 2021 10:57:15 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25607</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: AVW12(R) Specifications               Model AVW12（R）              Port size Rc3/8 Rc1/2 Rc3/4 Rc1 Rc11／4 Rc11／2 Rc2             Working pressure 0 〜 0.7MPa 0.15 〜 0.7MPa             Pilot [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-avw12r-2-position-2-port-air-operated-valves/">KONAN AVW12(R) 2-Position, 2-Port Air-operated Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: AVW12(R)</p>
<h1>Specifications</h1>
<table>
<tbody>
<tr>
<td width="187">              Model</td>
<td colspan="7" width="497">AVW12（R）</td>
</tr>
<tr>
<td width="187">             Port size</td>
<td width="71">Rc3/8</td>
<td width="71">Rc1/2</td>
<td width="71">Rc3/4</td>
<td width="71">Rc1</td>
<td width="71">Rc11<strong>／</strong>4</td>
<td width="71">Rc11<strong>／</strong>2</td>
<td width="71">Rc2</td>
</tr>
<tr>
<td width="187">            Working pressure</td>
<td colspan="4" width="284">0 〜 0.7MPa</td>
<td colspan="3" width="213">0.15 〜 0.7MPa</td>
</tr>
<tr>
<td width="187">            Pilot pressure</td>
<td colspan="4" width="284">0.2 〜 0.7MPa</p>
<p>(Pilot pressure ≧ Operating pressure)</td>
<td colspan="3" width="213">0.15 〜 0.7MPa</p>
<p>(Pilot pressure ≧ Operating pressure)</td>
</tr>
<tr>
<td width="187">           Fluid temperature</td>
<td colspan="7" rowspan="2" width="497">— 20 〜 60℃</p>
<p>Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.</td>
</tr>
<tr>
<td width="187">            Ambient temperature</td>
</tr>
<tr>
<td width="187">        Effective sectional area</td>
<td width="71">30mm<sup>2</sup></td>
<td width="71">49mm<sup>2</sup></td>
<td width="71">83mm<sup>2</sup></td>
<td width="71">137mm<sup>2</sup></td>
<td width="71">350mm<sup>2</sup></td>
<td colspan="2" width="142">800mm<sup>2</sup></td>
</tr>
<tr>
<td width="187">Max. operating frequency</td>
<td colspan="7" width="497">1 回 /s  1 cycle /s</td>
</tr>
<tr>
<td width="187">          Internal leakage</td>
<td colspan="7" width="497">JIS B 8373：2015 Less than value of the standard</td>
</tr>
<tr>
<td width="187">        Installation position</td>
<td colspan="7" width="497">Free</td>
</tr>
<tr>
<td width="187">                                                Mass</td>
<td colspan="2" width="142">1.4kg</td>
<td colspan="2" width="142">2.9kg</td>
<td width="71">8.0kg</td>
<td colspan="2" width="142">10.0kg</td>
</tr>
</tbody>
</table>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25608 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-95.png" alt="AVW12(R" width="746" height="407" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-95.png 746w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-95-300x164.png 300w" sizes="auto, (max-width: 746px) 100vw, 746px" /></p>
<h1>Operation</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25609 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-59.png" alt="AVW12(R" width="1002" height="235" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-59.png 1002w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-59-300x70.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-59-768x180.png 768w" sizes="auto, (max-width: 1002px) 100vw, 1002px" /></p>
<h1>External Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25610 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/1-59.png" alt="AVW12(R" width="576" height="271" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/1-59.png 576w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-59-300x141.png 300w" sizes="auto, (max-width: 576px) 100vw, 576px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-25611 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/2-41.png" alt="AVW12(R" width="672" height="248" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/2-41.png 672w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-41-300x111.png 300w" sizes="auto, (max-width: 672px) 100vw, 672px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-25612 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/3-15.png" alt="AVW12(R" width="616" height="313" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/3-15.png 616w, https://koueitrading.com/global/wp-content/uploads/2021/02/3-15-300x152.png 300w" sizes="auto, (max-width: 616px) 100vw, 616px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-25613 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/4-15.png" alt="AVW12(R" width="574" height="312" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/4-15.png 574w, https://koueitrading.com/global/wp-content/uploads/2021/02/4-15-300x163.png 300w" sizes="auto, (max-width: 574px) 100vw, 574px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-avw12r-2-position-2-port-air-operated-valves/">KONAN AVW12(R) 2-Position, 2-Port Air-operated Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN MVS150C 2-Position, 4-Port Solenoid Valves</title>
		<link>https://koueitrading.com/global/product/konan-mvs150c-2-position-4-port-solenoid-valves/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Fri, 19 Feb 2021 01:18:12 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25569</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: MVS150C Specifications Model MVS120C MVS150C Port size Rc11／4 Rc11／2 Working pressure 0.2 〜 0.7MPa Fluid temperature — 20 〜 60℃  Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower. Ambient temperature — 20 〜 50℃ Effective sectional area 250mm2 300mm2 Response [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-mvs150c-2-position-4-port-solenoid-valves/">KONAN MVS150C 2-Position, 4-Port Solenoid Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: MVS150C</p>
<h1>Specifications</h1>
<table>
<tbody>
<tr>
<td width="189">Model</td>
<td colspan="2" width="248">MVS120C</td>
<td width="248">MVS150C</td>
</tr>
<tr>
<td width="189">Port size</td>
<td colspan="2" width="248">Rc11<strong>／</strong>4</td>
<td width="248">Rc11<strong>／</strong>2</td>
</tr>
<tr>
<td width="189">Working pressure</td>
<td colspan="3" width="495">0.2 〜 0.7MPa</td>
</tr>
<tr>
<td width="189">Fluid temperature</td>
<td width="203">— 20 〜 60℃</td>
<td colspan="2" rowspan="2" width="292"> Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.</td>
</tr>
<tr>
<td width="189">Ambient temperature</td>
<td width="203">— 20 〜 50℃</td>
</tr>
<tr>
<td width="189">Effective sectional area</td>
<td colspan="2" width="248">250mm<sup>2</sup></td>
<td width="248">300mm<sup>2</sup></td>
</tr>
<tr>
<td width="189">Response time</td>
<td colspan="3" width="495">0.2s 以 下 ≦ 0.2 s</td>
</tr>
<tr>
<td width="189">Max. operating frequency</td>
<td colspan="3" width="495">1 回 /s  1 cycle /s</td>
</tr>
<tr>
<td width="189">Internal leakage</td>
<td colspan="3" width="495">JIS B 8373：2015 Less than value of the standard</td>
</tr>
<tr>
<td width="189"><strong> </strong></p>
<p>Installation position</td>
<td colspan="3" width="495">It is desirable to mount the valve with the spool located horizontally.</td>
</tr>
<tr>
<td width="189">Mass</td>
<td colspan="2" width="248">17kg</td>
<td width="248">20kg</td>
</tr>
</tbody>
</table>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-25561" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-91.png" alt="" width="1015" height="819" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-91.png 1015w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-91-300x242.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-91-768x620.png 768w" sizes="auto, (max-width: 1015px) 100vw, 1015px" /></p>
<p>&nbsp;</p>
<h1>External Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-25565" src="https://koueitrading.com/global/wp-content/uploads/2021/02/3-12.png" alt="" width="896" height="830" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/3-12.png 896w, https://koueitrading.com/global/wp-content/uploads/2021/02/3-12-300x278.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/3-12-768x711.png 768w" sizes="auto, (max-width: 896px) 100vw, 896px" /></p>
<h1>Parts</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-25566" src="https://koueitrading.com/global/wp-content/uploads/2021/02/5-3.png" alt="" width="600" height="510" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/5-3.png 600w, https://koueitrading.com/global/wp-content/uploads/2021/02/5-3-300x255.png 300w" sizes="auto, (max-width: 600px) 100vw, 600px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-25567 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/4-13.png" alt="MVS150C" width="1040" height="732" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/4-13.png 1040w, https://koueitrading.com/global/wp-content/uploads/2021/02/4-13-300x211.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/4-13-1024x721.png 1024w, https://koueitrading.com/global/wp-content/uploads/2021/02/4-13-768x541.png 768w" sizes="auto, (max-width: 1040px) 100vw, 1040px" /></p>
<h1>Operation</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25562 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-55.png" alt="MVS150C" width="989" height="396" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-55.png 989w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-55-300x120.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-55-768x308.png 768w" sizes="auto, (max-width: 989px) 100vw, 989px" /></p>
<h1>Structure</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25563 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/2-36.png" alt="MVS150C" width="956" height="592" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/2-36.png 956w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-36-300x186.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-36-768x476.png 768w" sizes="auto, (max-width: 956px) 100vw, 956px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-25564 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/1-54.png" alt="MVS150C" width="892" height="656" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/1-54.png 892w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-54-300x221.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-54-768x565.png 768w" sizes="auto, (max-width: 892px) 100vw, 892px" /><del></del></p>
<hr />
<p>&nbsp;</p>
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-mvs150c-2-position-4-port-solenoid-valves/">KONAN MVS150C 2-Position, 4-Port Solenoid Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN MVD150C 2-Position, 4-Port Solenoid Valves</title>
		<link>https://koueitrading.com/global/product/konan-mvd150c-2-position-4-port-solenoid-valves/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Fri, 19 Feb 2021 00:44:58 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25588</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: MVD150C Specifications Model MVD120C MVD150C Port size Rc11／4 Rc11／2 Working pressure 0.2 〜 0.7MPa Fluid temperature — 20 〜 60℃ Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower. Ambient temperature — 20 〜 50℃ Effective sectional area 250mm2 300mm2 Response [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-mvd150c-2-position-4-port-solenoid-valves/">KONAN MVD150C 2-Position, 4-Port Solenoid Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: MVD150C</p>
<h1>Specifications</h1>
<table>
<tbody>
<tr>
<td width="189">Model</td>
<td colspan="2" width="248">MVD120C</td>
<td width="248">MVD150C</td>
</tr>
<tr>
<td width="189">Port size</td>
<td colspan="2" width="248">Rc11<strong>／</strong>4</td>
<td width="248">Rc11<strong>／</strong>2</td>
</tr>
<tr>
<td width="189">Working pressure</td>
<td colspan="3" width="495">0.2 〜 0.7MPa</td>
</tr>
<tr>
<td width="189">Fluid temperature</td>
<td width="201">— 20 〜 60℃</td>
<td colspan="2" rowspan="2" width="294">Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.</td>
</tr>
<tr>
<td width="189">Ambient temperature</td>
<td width="201">— 20 〜 50℃</td>
</tr>
<tr>
<td width="189">Effective sectional area</td>
<td colspan="2" width="248">250mm<sup>2</sup></td>
<td width="248">300mm<sup>2</sup></td>
</tr>
<tr>
<td width="189">Response time</td>
<td colspan="3" width="495">0.2s 以 下 ≦ 0.2 s</td>
</tr>
<tr>
<td width="189">Max. operating frequency</td>
<td colspan="3" width="495">1 回 /s  1 cycle /s</td>
</tr>
<tr>
<td width="189">Internal leakage</td>
<td colspan="3" width="495">JIS B 8373：2015 Less than value of the standard</td>
</tr>
<tr>
<td width="189"><strong> </strong></p>
<p>Installation position</td>
<td colspan="3" width="495">It is desirable to mount the valve with the spool located horizontally.</td>
</tr>
<tr>
<td width="189">Mass</td>
<td colspan="2" width="248">18kg</td>
<td width="248">22kg</td>
</tr>
</tbody>
</table>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-25581" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-93.png" alt="" width="1006" height="791" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-93.png 1006w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-93-300x236.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-93-768x604.png 768w" sizes="auto, (max-width: 1006px) 100vw, 1006px" /></p>
<h1>Operation</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-25582" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-57.png" alt="" width="991" height="420" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-57.png 991w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-57-300x127.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-57-768x325.png 768w" sizes="auto, (max-width: 991px) 100vw, 991px" /></p>
<h1>Structure</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25583 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/2-37.png" alt="MVD150C" width="929" height="495" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/2-37.png 929w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-37-300x160.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-37-768x409.png 768w" sizes="auto, (max-width: 929px) 100vw, 929px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-25584 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/1-55.png" alt="MVD150C" width="621" height="691" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/1-55.png 621w, https://koueitrading.com/global/wp-content/uploads/2021/02/1-55-270x300.png 270w" sizes="auto, (max-width: 621px) 100vw, 621px" /></p>
<h1>External Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25585 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/3-13.png" alt="MVD150C" width="883" height="783" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/3-13.png 883w, https://koueitrading.com/global/wp-content/uploads/2021/02/3-13-300x266.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/3-13-768x681.png 768w" sizes="auto, (max-width: 883px) 100vw, 883px" /></p>
<h1>Parts</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25589 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/2-38.png" alt="MVD150C" width="494" height="219" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/2-38.png 494w, https://koueitrading.com/global/wp-content/uploads/2021/02/2-38-300x133.png 300w" sizes="auto, (max-width: 494px) 100vw, 494px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>The post <a href="https://koueitrading.com/global/product/konan-mvd150c-2-position-4-port-solenoid-valves/">KONAN MVD150C 2-Position, 4-Port Solenoid Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN MVM50 2-Position, 5-Port Solenoid Valves</title>
		<link>https://koueitrading.com/global/product/konan-mvm50-2-position-5-port-solenoid-valves/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Thu, 18 Feb 2021 23:58:32 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25553</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: MVM50 Model Code External Dimensions Kouei is Distributor/Agent of KONAN. Other items of KONAN. Request the quotation for KONAN. &#160;</p>
The post <a href="https://koueitrading.com/global/product/konan-mvm50-2-position-5-port-solenoid-valves/">KONAN MVM50 2-Position, 5-Port Solenoid Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: MVM50</p>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25554 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-45.png" alt="MVM50" width="1047" height="736" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-45.png 1047w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-45-300x211.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-45-1024x720.png 1024w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture2-45-768x540.png 768w" sizes="auto, (max-width: 1047px) 100vw, 1047px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-25555 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-90.png" alt="MVM50" width="1024" height="677" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-90.png 1024w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-90-300x198.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-90-768x508.png 768w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-90-180x118.png 180w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture-90-575x380.png 575w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /></p>
<h1>External Dimensions</h1>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-25556 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-54.png" alt="MVM50" width="948" height="848" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-54.png 948w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-54-300x268.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture1-54-768x687.png 768w" sizes="auto, (max-width: 948px) 100vw, 948px" /> <img loading="lazy" decoding="async" class="alignnone wp-image-25557 size-full" src="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-24.png" alt="MVM50" width="942" height="838" srcset="https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-24.png 942w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-24-300x267.png 300w, https://koueitrading.com/global/wp-content/uploads/2021/02/Capture3-24-768x683.png 768w" sizes="auto, (max-width: 942px) 100vw, 942px" /></p>
<hr />
<ul>
<li>Kouei is Distributor/Agent of <b>KONAN.</b></li>
<li><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></li>
<li><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></li>
</ul>
<p>&nbsp;</p>
<div id="gtx-trans" style="position: absolute; left: 77px; top: 90.075px;">
<div class="gtx-trans-icon"></div>
</div>The post <a href="https://koueitrading.com/global/product/konan-mvm50-2-position-5-port-solenoid-valves/">KONAN MVM50 2-Position, 5-Port Solenoid Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KONAN AVS120C 2-Position, 4-Port Air-Operated Valves</title>
		<link>https://koueitrading.com/global/product/konan-avs120c-2-position-4-port-air-operated-valves/</link>
		
		<dc:creator><![CDATA[kvtpart]]></dc:creator>
		<pubDate>Thu, 18 Feb 2021 22:47:02 +0000</pubDate>
				<guid isPermaLink="false">https://koueitrading.com/global/?post_type=product&#038;p=25636</guid>

					<description><![CDATA[<p>Product Made In Japan Manufacturer: KONAN ELECTRIC Model: AVS120C Specifications Model AVS120C AVS150C Port size Rc11／4 Rc11／2 Working pressure 0.2 〜 0.7MPa Pilot pressure 0.2 〜 0.7MPa (Pilot pressure ≧ Operating pressure) Fluid temperature — 20 〜 60℃                  Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower. Ambient temperature [&#8230;]</p>
The post <a href="https://koueitrading.com/global/product/konan-avs120c-2-position-4-port-air-operated-valves/">KONAN AVS120C 2-Position, 4-Port Air-Operated Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></description>
										<content:encoded><![CDATA[<p>Product Made In Japan<br />
Manufacturer: KONAN ELECTRIC<br />
Model: AVS120C</p>
<h1>Specifications</h1>
<table>
<tbody>
<tr>
<td style="text-align: center;" width="189"><strong>Model</strong></td>
<td style="text-align: center;" width="246"><strong>AVS120C</strong></td>
<td style="text-align: center;" width="246"><strong>AVS150C</strong></td>
</tr>
<tr>
<td width="189"><strong>Port size</strong></td>
<td style="text-align: center;" width="246">Rc11<strong>／</strong>4</td>
<td style="text-align: center;" width="246">Rc11<strong>／</strong>2</td>
</tr>
<tr>
<td width="189"><strong>Working pressure</strong></td>
<td style="text-align: center;" colspan="2" width="493">0.2 〜 0.7MPa</td>
</tr>
<tr>
<td width="189"><strong>Pilot pressure</strong></td>
<td colspan="2" width="493">
<p style="text-align: center;">0.2 〜 0.7MPa</p>
<p style="text-align: center;">(Pilot pressure ≧ Operating pressure)</p>
</td>
</tr>
<tr>
<td width="189"><strong>Fluid temperature</strong></td>
<td style="text-align: center;" colspan="2" rowspan="2" width="493">— 20 〜 60℃                  Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.</td>
</tr>
<tr>
<td width="189"><strong>Ambient temperature</strong></td>
</tr>
<tr>
<td width="189"><strong>Effective sectional area</strong></td>
<td style="text-align: center;" width="246">250mm<sup>2</sup></td>
<td style="text-align: center;" width="246">300mm<sup>2</sup></td>
</tr>
<tr>
<td width="189"><strong>Max. operating frequency</strong></td>
<td style="text-align: center;" colspan="2" width="493">1 回 /s  1 cycle /s</td>
</tr>
<tr>
<td width="189"><strong>Internal leakage</strong></td>
<td style="text-align: center;" colspan="2" width="493">JIS B 8373：2015 Less than value of the standard</td>
</tr>
<tr>
<td width="189"><strong>Installation position</strong></td>
<td style="text-align: center;" colspan="2" width="493">It is desirable to mount the valve with the spool located horizontally.</td>
</tr>
<tr>
<td width="189"><strong>Mass</strong></td>
<td style="text-align: center;" width="246">16kg</td>
<td style="text-align: center;" width="246">19kg</td>
</tr>
</tbody>
</table>
<h1>Model Code</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-108544" src="https://koueitrading.com/global/wp-content/uploads/2024/05/Screenshot-2024-05-07-162222.png" alt="" width="737" height="279" srcset="https://koueitrading.com/global/wp-content/uploads/2024/05/Screenshot-2024-05-07-162222.png 737w, https://koueitrading.com/global/wp-content/uploads/2024/05/Screenshot-2024-05-07-162222-300x114.png 300w" sizes="auto, (max-width: 737px) 100vw, 737px" /></p>
<h1>Operation</h1>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-108545" src="https://koueitrading.com/global/wp-content/uploads/2024/05/Screenshot-2024-05-07-162215.png" alt="" width="815" height="268" srcset="https://koueitrading.com/global/wp-content/uploads/2024/05/Screenshot-2024-05-07-162215.png 815w, https://koueitrading.com/global/wp-content/uploads/2024/05/Screenshot-2024-05-07-162215-300x99.png 300w, https://koueitrading.com/global/wp-content/uploads/2024/05/Screenshot-2024-05-07-162215-768x253.png 768w" sizes="auto, (max-width: 815px) 100vw, 815px" /></p>
<h1>External Dimensions</h1>
<table>
<thead>
<tr>
<th>Model</th>
<th>DD</th>
<th>AA</th>
<th>BB</th>
<th>EE</th>
<th>FF</th>
<th>LL</th>
<th>φKK</th>
<th>SS</th>
<th>RR</th>
<th>TT</th>
<th>CC</th>
</tr>
</thead>
<tbody>
<tr>
<td style="text-align: center;">AVS120C-32A</td>
<td style="text-align: center;">1 1/4</td>
<td style="text-align: center;">202</td>
<td style="text-align: center;">80</td>
<td style="text-align: center;">96</td>
<td style="text-align: center;">120</td>
<td style="text-align: center;">313.5</td>
<td style="text-align: center;">11</td>
<td style="text-align: center;">170</td>
<td style="text-align: center;">40</td>
<td style="text-align: center;">21</td>
<td style="text-align: center;">66.5</td>
</tr>
<tr>
<td style="text-align: center;">AVS150C-40A</td>
<td style="text-align: center;">1 1/2</td>
<td style="text-align: center;">200</td>
<td style="text-align: center;">85</td>
<td style="text-align: center;">120</td>
<td style="text-align: center;">150</td>
<td style="text-align: center;">313.5</td>
<td style="text-align: center;">14</td>
<td style="text-align: center;">185</td>
<td style="text-align: center;">45</td>
<td style="text-align: center;">21</td>
<td style="text-align: center;">65.5</td>
</tr>
</tbody>
</table>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-108543" src="https://koueitrading.com/global/wp-content/uploads/2024/05/Screenshot-2024-05-07-162157.png" alt="" width="818" height="658" srcset="https://koueitrading.com/global/wp-content/uploads/2024/05/Screenshot-2024-05-07-162157.png 818w, https://koueitrading.com/global/wp-content/uploads/2024/05/Screenshot-2024-05-07-162157-300x241.png 300w, https://koueitrading.com/global/wp-content/uploads/2024/05/Screenshot-2024-05-07-162157-768x618.png 768w" sizes="auto, (max-width: 818px) 100vw, 818px" /></p>
<hr />
<p>Kouei is Distributor/Agent of <b>KONAN.</b></p>
<p><a href="https://koueitrading.com/global/product-cat/konan/"><strong>Other items of KONAN.</strong></a></p>
<p><a href="https://koueitrading.com/global/contact/"><strong>Request the quotation for KONAN.</strong></a></p>The post <a href="https://koueitrading.com/global/product/konan-avs120c-2-position-4-port-air-operated-valves/">KONAN AVS120C 2-Position, 4-Port Air-Operated Valves</a> first appeared on <a href="https://koueitrading.com/global">Kouei Japan Trading | Get Quotation</a>.]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>