Toyo Keiki
Toyo Keiki CF Series Fixed Meters
Product Made In Japan
Manufacturer: Toyo Keiki
Model: CF Series
Specified Items when Ordering Electrical Indicating Meters
1. Pointer shape
a. Standard pointer: Cannot be specified
b. Rod pointer or knife shape pointer: Specification required
2. Meter mounting posture
a. Vertical ( ): Cannot be specified
b. Horizontal ( ) Diagonal ( ): Specification required
3. Meter Mounting Panel
Iron and non-ferrous metal: Cannot be specified
Inclusion Insulating rubber: Specification required
4. Cover color
a. Black: Cannot be specified
b. 7.5 BG4/1.5: Specification required
5. Measurement Range Value
a. Recommended value
b. Upper limit other than the recommended value
6. Scale
a. Same scale as upper limit value inherent to meter
b. Scale that differs from upper limit value
c. Scale division outside the recommended value
d. Single scale double printing
Double scale double printing
e. Unit Symbol
μA mA A V kV W kW MW cos kvar Hz rpm m/min etc.
f. Color display (colored line and band)
(Only available in red, green and yellow)
7. Record of results
500 yen per set if requested
8. Delivery specifications
1500 yen for up to 5 sets if requested
300 yen for each additional set
On-site inspection
Quoted separately.
9. Others
a. Change in accuracy class
b. Special conditions such as temperature,
humidity, atmosphere, vibration, etc.
1. All models are equipped with a terminal cap if requested.
2. Both 500 and 600V DC and rectier series resistors are now built in.
3. ECF-12NB, RCF-12NB and UuCF-12NB types:
1) Ammeter type was changed to the electronic device type and a transducer is now built in.
2) Terminal cap was attached.
3) Consumption VA was reduced.
4. RoHS compliant product (however, the taut band of the DCF-6, 8, 10 and 12N type 50μA and 100μA meters are non-RoHS products.)
Electric transducer system provided with □CF-6, 8, 10 models (□: E, R, U, Uu) The converter was reduced in size to unify with the □RG-3 type (with terminal cover).
The insulation category is CAT III 600V For the AC voltmeter and AC ammeter ACF-□ type (operating principle: moving-iron type), even without installing the insulating rubber. (600V is the maximum circuit voltage value that can be used)
The insulation category is CAT III 300V for meters other than those indicated above when using only the meter body (without the insulating rubber). (300V is the maximum circuit voltage value that can be used)
The insulation category is raised to CAT III 600V if the insulating rubber is installed on the panel board.
Features
1. Meter has a bright scale face due to the wide cover lighting surface.
2. Accuracy of readability has increased due to the long scale length compared to the meter’s size.
3. A variety of sizes are available so you can choose a meter that best suits the size of your switchboard.
Features Cover eliminates static electricity.
Equipped with special anti-static resin.
Maintaining an anti-static finish is not necessary.
Static phenomena will not occur even in low humidity.
Production Standards
Model Name | □CF-5 | □CF-6 | □CF-8 | □CF-10 | □CF-12n* 12nb |
---|---|---|---|---|---|
Front Dimensions (Horizontal x Vertical) [mm] | 56×52 | 65×60 | 87×80 | 100×83 | 120×100 |
JIS Symbol | – | KS7 Equivalent | KS6a Equivalent | KS5b Equivalent | KS3d Equivalent |
Scale Length [mm] | 45 | 53 | 68 | 80 | 100 |
Accuracy Class | See the CF Series List | ||||
Panel Attached to Meter | Cannot be Specified (Specification required for high-sensitivity meters of DC 100 pA or less) | ||||
Mounting Posture | Vertical (Other than vertical: Specification req | uired, e.g. s’ 30°) | |||
Recommended No. of Scale Divisions | Division 12 to division 25 | Division 12 to division 25 | Division 12 to division 25 | Division 20 to division 45 | Division 24 to division 50 |
Pointer Shape | Rod Pointer | CF Type Standard Pointer (See the figure below) | |||
Cover Material | Special Anti-electric Resin (Two-color molding) | ||||
Cover Frame Color | • Black (Munsell Notation: N-1.5 • Blue-green (Munsell Notation: 7.5B G4 / 1.5) | ||||
Base Material | ABS Resin | ||||
Scale Plate | Aluminum plate with white coating (Scale lines and numbers are black) |
Insulation Test Between all circuits in a batch and outer casing…… More than 10MΩ (at 500V mega )
Between current circuit and voltage circuit…… More than 5MΩ (at 500V mega )
Voltage Test Between all measurement circuits in a batch and outer casing, and between current circuit and voltage circuit
…… CAT III 300V: AC 2210V (50/60Hz) for 5 seconds (300V is the maximum circuit voltage value that can be used)
Between all measurement circuits in a batch and outer casing, and between current circuit and voltage circuit
……CAT III 600V: AC 3320V (50/60Hz) for 5 seconds (600v is the maximum circuit voltage value that can be used)
Product Name | □CF-5 | □CF-6 | □CF-8 | □CF-10 | □CF-12N | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Model Name | Operating Principles | Accuracy Class | Model Name | Operating Principles | Accuracy Class | Model Name | Operating Principles | Accuracy Class | Model Name | Operating Principles | Acauracy Cass | Model Name | Operating Principles | Accuracy Class | ||
Direct Current | Ammeter | DCF-5 | Permanent Rectifier Type |
2.5 | DCF-6 | Permanent
Magnet |
2.5 | DCF-8 | Permanent
Magnet |
2.5 | DCF-10 | Permanent
Magnet |
2.5 | DCF-12N | Permanent
Magnet |
1.5 |
Voltmeter | ||||||||||||||||
Reception Meter | ||||||||||||||||
Alternating Current | Ammeter | SCF-5 | 2.5 | SCF-6 | Rectifier Type |
2.5 | SCF-8 | Rectifier Type |
2.5 | SCF-10 | Rectifier Type |
2.5 | SCF-12N | Rectifier Type |
2.5 | |
Voltmeter | ||||||||||||||||
Ammeter | ACF-5 | Moving-irontype | 2.5 | ACF-6 | Moving- | 2.5 | ACF-8 | Moving- | 2.5 | ACF-10 | Moving- | 2.5 | ACF-12NB | Moving- | 1.5 | |
Voltmeter | Iron Type | Iron Type | Iron Type | Iron Type | ||||||||||||
Reception Meter T |
SCF-5 | Rectifier Type | 2.5 | SCF-6 | Recifer Type | 2.5 | SCF-8 | Rectifer Type | 2.5 | SCF-10 | Rectifer Type | 2.5 | SCF-12N | Rectiher Type | 2.5 | |
1P Wattmeter 3P Wattmeter 3P4W Wattmeter |
ECF-6 | Electronic Device Type |
2.5 | ECF-8 | Electronic Device Type |
2.5 | ECF-10 | Electronic Device Type |
2.5 | ECF-12NB | Electronic Device Type |
1.5 | ||||
1P Varmeter 3P Varmeter 3P4W Varmeter |
RCF-6 | Electronic Device Type |
2.5 | RCF-8 | Electronic Device Type |
2.5 | RCF-10 | Electronic Device Type |
2.5 | RCF-12NB | Electronic Device Type |
1.5 | ||||
1P Power Factor Meter 3P Balanced Power Rate Meter |
UCF-6 | Electronic Device |
5.0 | UCF-8 | Electronic Device |
5.0 | UCF-10 | Electronic Device |
5.0 | UCF-12NB | Electronic Device |
5.0 | ||||
3PUnbalancedPower Fador Meter 3P4WPower Factor Meter |
UuCF-6 | Type | UuCF-8 | Type | UuCF-10 | Type | UuCF-128 | Type | ||||||||
Frequency Meters | FCF-6 | Electronic Device Type |
1.0 | FCF-8 | Electronic Device Type |
1.0 | FCF-10 | Electronic Device Type |
1.0 | FCF-12NB | Electronic Device Type |
0.5 | ||||
Tachometer | CCF-5 | Rectifer Type | Intrinsic Eror +2.5% |
CCF-6 | Rectifer Type | Intrinsic Emor +25% |
CCF-8 | Rectiher Type | Intrinsc Emror +25% |
CCF-10 | Rectifer Type | Intrinsc Emror +25% |
CCF-12N | Rectifier Type | Intrinsic Emror +15% |
Special Specifications
(Can be manufactured to the following special specications by request)
◆ Mounting posture other than vertical (Specification of installation angle required)
◆ With red set pointer
◆ Special Scale: Conversion scale, zero center scale, colored scale, multiple scale, magnified scale, specific symbol display, scale division increase in lines
◆ Rod pointer (Rod pointer is used for multiple scales)
◆ Knife shape pointer with mirror (for CF-8, 10, 12N types)
◆ Special processing (heat processing, etc.)
◆ Other special specifications
Operating Environment
Operating Temperature Limits : −10°C to +50°C, Accuracy +5°C to +40°C
Storage Temperature: −20°C to +60°C
Relative Humidity: Less than 80%
Operating Environment : Indoor
Installation Height: 2000m or less
Assurance Range: +5°C to +40°C
Made of silicon rubber
(2mm thick)
◆ Insulating Rubber
When the meter is installed on a panel board, use of this insulating rubber can increase dielectric strength.
(Measurement category) CAT III 300V → CAT III 600V