Toyo Keiki
Toyo Keiki CF Series Power Factor Meter
Product Made In Japan
Manufacturer: Toyo Keiki
Model: CF Series
Features
1. Meter has a bright scale face due to the wide cover lighting surface.
2. Accuracy of readability has increased due to the long scale length compared to the meter’s size.
3. A variety of sizes are available so you can choose a meter that best suits the size of your switchboard.
Features Cover eliminates static electricity.
Equipped with special anti-static resin.
Maintaining an anti-static finish is not necessary.
Static phenomena will not occur even in low humidity.
Electronic Device Type, Phase Detection Method
Model Name | 1P Power Factor Meter and 3P Balanced Power Rate Meter | UCF-6 UCF-8 UCF-10 UCF-12NB |
---|---|---|
3P Unbalanced Power Factor Meter and 3P4W Power Factor Meter | UuCF-6 UuCF-8 UuCF-10 UuCF-12NB |
Specification
Product Name | Model Name | Scale | Operating Principles | Rating | VA Consumption | Attached Converter | Weight | Note | ||
---|---|---|---|---|---|---|---|---|---|---|
Voltage Circuit | Current Circuit | Meters | Accessories | |||||||
1P Power Factor Meter | UCF-6 UCF-8 UCF-10 | LEAD LAG 0.5-1 ~0.5 | Electronic Device Type | 110V 5A 200V 5A | 0.8 VA 1.3 VA | 0.8VA 0.8VA | URG-3 type | Approx. 0.14kg Approx. 0.16kg Approx. 0.18kg | Approx. 0.60kg | 50/60Hz Common Use |
UCF-12nb | 110V 5A 220V 5A | 1 VA 2VA | 0.5 VA 0.5 VA | None | Approx. 0.42kg | |||||
3P Balanced Power Factor Meter | UCF-6 UCF-8 UCF-10 | Electronic Device Type | 110V 5A 220V 5A | 0.8 VA 1.3 VA | 0.8VA 0.8VA | URG-3 type | Approx. 0.14kg Approx. 0.16kg Approx. 0.18kg | Approx. 0.60kg | 50/60Hz Common Use | |
UCF-12nb | 1105A 220V 5A | 1 VA 2VA | 0.5VA 0.5VA | None | Approx. 0.41 kg | |||||
3P Unbalanced Power Factor Meter | UuCF-6 UuCF-8 UuCF-10 | Electronic Device Type | 110V 5A 220V 5A | 0.5VA per phase 1VA per phase | 0.8VA per phase 0.8VA per phase | UuRG-3 models | Approx. 0.14kg Approx. 0.16kg Approx. 0.18kg | Approx. 0.62kg | 50or60Hz Specification required | |
UuCF-12nb | 110V 5A 220V 5A | 1VA per phase 2VA per phase | 0.5VA per phase 0.5VA per phase | None | Approx. 0.45kg | |||||
3P4W Power Factor Meter | UuCF-6 UuCF-8 UuCF-10 | Electronic Device Type | 110V 5A 220V 5A | 1.5VA per phase 3VA per phase | 2VA per phase 2VA per phase | UuRG-3 models | Approx. 0.14kg Approx. 0.16kg Approx. 0.18kg | Approx. 0.62kg | 50or60Hz Required Designation | |
UuCF-12nb | 110V 5A 220V 5A | 1VA per phase 2VA per phase | 0.5VA per phase 0.5VA per phase | None | Approx. 0.47kg |
Remarks
VT and CT Usage Use a 110V5A rating meter combined with VT and CT if the rating above is exceeded.
Usable Voltage Range Rated voltage within ±15%
For Small Current When circuit voltage is rated under 20% (5A rating: less than 1A), it may not be possible to obtain a normal indicator.
(Indicates “1” scale if the power is off)
Meter Wiring
- You cannot obtain a normal indicator if phase is reversed. Therefore, be sure to check the phase sequence of the bus and the polarity of VT and CT.
- For phenomena related to miswiring, see P32.
Note
Voltage rated value 1A meters can also be manufactured.
Outside Dimensions
For the production limits of meters, see P18.
Scale Drawing
Related Products
-
Toyo Keiki VLS-A Series AC Voltage Transducer Transducer
-
TOYO KEIKI RGM Series Var Transducer
-
TOYO KEIKI GP and HP Series Power Factor Transducer
-
Toyo Keiki EVF-11M-RVF-11M Wattmeter and Varmeter Electronic Device Type Time Sharing Multiplication Method
-
Toyo Keiki SVF-11M Rectifier Type AC Ammeter
-
Toyo Keiki AVF-11M AC Voltmeter Moving-iron Type R.M.S.-Response