NOHMI BOSAI
NOHMI BOSAI FDKU033-D/FDKU033-D-X Multi-criteria Analog Addresable Smoke Detector
Made in Japan
Manufacturer: NOHMI BOSAI
Model: FDKU033-D/FDKU033-D-X
Features of FDKU033-D/FDKU033-D-X
- UL268 7th Edition Listed
- Very Low Profile (28.7mm/1.13-inch in height)
- Wide Alarm Set-point Range of 4.4 to 8.4%/m (1.36 to 2.64%/foot)
- True Analog Detector
- UL listed Smoke Calibration and Sensitivity
- Simple and Accurate Address Setting without Mechanical Switches
- LEDs for 360°Viewing
Description of FDKU033-D/FDKU033-D-X
- The FDKU033 series is a Multi-Criteria Analog Addressable Smoke Detector compatible with any fire alarm control panels from the Integlex Multicrest series. Certified with UL268 7th Edition, the FDKU033 series meets stringent requirements, including flaming and smoldering polyurethane tests, as well as nuisance tests to prevent activation by certain types of cooking smoke.In addition to the standard UL268 7th Edition requirements, the FDKU033 series has a unique chamber that distinguishes between smoke and dust, helping to prevent false alarms. This chamber uses Nohmi’s latest detection technology, which reduces nuisance alarms and enhances fire detection reliability.
The FDKU033 series integrates Nohmi’s advanced circuit technology, reducing product size while maintaining high performance. Its slim design ensures that the detector blends seamlessly with modern buildings. The FDKU033 series has an adjustable alarm set-point range of 4.4 to 8.4%/m (1.36 to 2.64%/foot) and includes drift compensation with built-in dirty detector warnings. When the dirty level reaches the limit, users should clean or replace the detector to ensure accurate detection.
Communication between the FDKU033 series and control panels occurs over a proven digital network, enabling rapid alarm detection. With polling speeds of less than five seconds, the FDKU033 series easily surpasses UL speed requirements.
This detector also features 360° LED viewing and is compatible with Nohmi’s various detector bases. It’s simple to install, using the hand-held programmer for accurate address setting, which is more reliable than mechanical switches.
Specifications
No. | Item | FDKU033-D | FDKU033-D-X |
---|---|---|---|
1 | Working voltage range | 22.0 to 24.0 V | 22.0 to 24.0 V |
2 | Standby current | 250 µA | 250 µA |
3 | Alarm indicator | 2 LEDs | 2 LEDs |
4 | Alarm indicator current | 1.5 mA D.C | 1.5 mA D.C |
5 | Alarm set-point range | 4.4 to 8.4 %/m (1.36 to 2.64 %/ft) | 4.4 to 8.4 %/m (1.36 to 2.64 %/ft) |
6 | Installation temperature range | 0°C to 49°C (32°F to 120°F) | 0°C to 49°C (32°F to 120°F) |
7 | Operating relative humidity range | 0% to 93% (Non-condensing) | 0% to 93% (Non-condensing) |
8 | Start-up time | Max. 1 sec. | Max. 1 sec. |
9 | Color | Eggshell White | Eggshell White |
10 | Weight (without base) | 84g (2.96oz) | 88g (3.0oz) |
11 | Dimensions (without base) | Height: 28.7mm (1.13 inch), Diameter: 99mm (4.0 inches) | Height: 28.7mm (1.13 inch), Diameter: 99mm (4.0 inches) |
12 | Remote indicator | N/A | Available |
Setting the Address
Each addressable module, smoke detector, heat detector, and combination detector must have the address set before connecting the device to the Signaling Line Circuit (SLC) loop. The address is set using the hand-held programmer.
Compatible Bases
No. | Device | Description |
---|---|---|
1 | FZBU004-AB4 | 4 inches Standard Base |
2 | FZBU003-AB6 | 6 inches Standard Base |
3 | FZBU013-2Z | 4 inches Standard Base, 2 terminals (without remote indication circuit) |
4 | FZBU013-4Z | 4 inches Standard Base, 4 terminals |
5 | FZBU005-AIB | 6 inches base with an isolator module included. The base is pre-wired with a pluggable jumper to the module. |
6 | FZBU005-ARB | 6 inches base that includes a dual relay module. One relay is rated for 8 amps at 240 VAC/30 VDC and the second is rated for 2 amps at 240 VAC/30 VDC. The base is pre-wired with a pluggable jumper to the module. |
7 | FZBU005-ASB | 6 inches base with sounder module included. Sound pattern is provided from an external source. The base is pre-wired with a pluggable jumper into the module. |
Wiring Diagram
Related Products
-
NOHMI BOSAI FMM01U Series Manual Fire Alarm Station/ Manual Release Station
-
NOHMI BOSAI EH24 Electronic Horn
-
NOHMI BOSAI FAPN105N Series Fire Alarm Panel
-
NOHMI BOSAI FDKU634-D-X Multi-criteria Conventional Smoke Detetor
-
NOHMI BOSAI FDLJ Series Fixed Temperature Detector
-
NOHMI BOSAI N3060 Addressable Systems