Miyawaki GH5 Ball Float Steam Traps

Manufacturer: MIYAWAKI Inc.
Model: GH5

Features

Quick startup
Automatically discharges initial air and cold condensate.

Condensate recovery
With its high degree of back pressure tolerance, this model supports condensate recovery.

High discharge capacity
A double ported balance valve provides a large discharge capacity in comparison with single valve models.

Typical applications

Suitable for uses including large-scale heat exchangers in various industries, and in things such as industrial plants, foodstuff devices, dyeing/cleaning devices, and air conditioning devices.

Dimensions/Weight

Flanged

SizeDimensions (mm)Dimensions (in)Weight
LH1H2WLH1H2W(kg)(lb)
2”34020011527013.47.94.510.650,0110.3

*Available flange standards: ASME/JPI 300lb

With connection flange

GH5

Size

Flange standardsL dimensions

(mm)

H1H2WL dimensions

(in)

H1H2WWeight
(kg)(lb)
2”JIS
10K,16K,20K
55020011527021.77.94.510.663,0138.9
ASME/JPI
150lb,300lb
DIN PN16 (DN50)
2 1/2”JIS
10K,16K,20K
57022.463,0138.9
ASME/JPI
150lb,300lb
58022.866,0145.5
DIN PN16 (DN65)
3″JIS
10K,16K,20K
57022.466,0145.5
ASME/JPI
150lb,300lb
58022.870,0154.4
DIN PN16 (DN80)
4″

JIS
10K,16K,20K

60023.670,0154.4
ASME/JPI
150lb,300lb
62024.480,0176.4
DIN PN16 (DN100)

*Available flange standards: ASME/JPI 150lb, 300lb,  DIN PN40,  JIS 10K, 16K, 20K
*Customized face-to-face dimensions on request.
*Please contact MIYAWAKI for further information.

Specifications

ModelConnectionMax. operating

pressure

Max. operating differential

pressure

Max. operating

temperature

Body material
TypeSizePMO (MPa)PMO (psig)⊿PMX (MPa)⊿PMX (psig)TMO (℃)TMO (℉)
GH5-10Flanged

RF*1

2”1,01451,0145400752Cast steel
SCPH2
GH5-161,62301,6230
GH5-212,13052,1305
GH5-10RFlanged

FF,RF*2

2”
2 1/2”
3″
4″
1,01451,0145
GH5-16R1,62301,6230
GH5-21R2,13052,1305

*1 Available flange standards: ASME/JPI 300lb
*2 Available flange standards: ASME/JPI 150lb, 300lb, DIN PN40, JIS 10K, 16K, 20K
This product uses a double ported balance valve system so if the actual condensate volume is significantly lower than the product’s discharge capacity, there may be a steam leak.

Discharge Capacity

The discharge line chart shows the discharge rate for condensate with a temperature 6℃ (11℉) lower than the saturation temperature.

 

REQUEST QUOTATION

PAYMENT

payment-methods

Return Top