Fluke
Fluke 1620A Digital Thermo-Hygrometer DewK
Manufacturer: Fluke Calibration
Model: 1620A
Features
- Excellent accuracy
- Network connection possible
- Effective Record Analysis Tool
- Two interchangeable calibrated sensors
- Large capacity memory
- Upgraded Software
Specification
specification | |
Operating range |
0 °C to 50 °C; 0% RH to 100% RH |
Calibration Temperature Accuracy (“H” model) |
± 0.125 °C (16 °C to 24 °C |
Calibration Temperature Accuracy (“S” Model) |
± 0.25 °C (15 °C to 35 °C) |
Calibrated relative humidity accuracy (“H” model) |
± 1.5% RH (20% RH to 70% RH) |
Calibrated relative humidity accuracy (“S” Model) |
± 2% RH (20% RH to 70% RH) |
Estimated Expected Value (No warranty) |
±0.5 °C outside calibration range |
Delta Temperature Accuracy |
± 0.025 °C for ± 1 ° change in the range 15 °C to 35 °C |
Temperature resolution |
Front panel selectable down to 0.001 °C (0.01° for logged data) |
Delta Humidity Accuracy |
± 1.0% RH: ± 5% change in the range of 20% RH to 70% RH |
Humidity Resolution |
Front panel selectable down to 0.01% (0.1% for logged data) |
input |
Measures temperature and relative humidity with up to two probes, removable, extendable with cable, replaceable, with built-in calibration, assignable 16 character ID (identification number) |
display |
240×128 Graphics Monochrome LCD, password protected, displays temperature/humidity data in graphical, numeric and statistical formats, 16 configurable display settings |
memory |
400,000 records with time stamps |
alarm |
Visual, audible and external alarms for temperature, temperature change, RH, RH change and faults (password protected) |
Alarm Port Output |
2.5 mm subminiature plug (normally 0 V, outputs 11-12 V, up to 20 mA when activated) |
connection |
Ethernet, RS-232 |
Ethernet |
RJ45 jack, 10 Base-T or 100 Base-TX; Static or Dynamic (DHCP client) IP address authentication |
web page |
Built-in web page interface and functions: device identification, measurements, password-protected device page (can be disabled) |
attachment |
Wall mounted (mounting included) or bench mounted |
power supply |
12 V DC from an external 100-240 V AC power adapter |
Battery Assistance |
Standard built-in 9 V battery allows measurements even during power outages |
Dimensions (DewK) ( HxWxD ) |
125mm x 211mm x 51mm |
Dimensions (sensor)(Length x diameter) |
79mm x 19mm |
weight |
0.7 kg |
Proofreading |
NVLAP calibration certificate for temperature and humidity. Data included is for 3 temperature points and 3 humidity points at 20°C. Compliant with NCSL/ISO/IEC 17025:2000 and ANSI/NCSL Z540-1-1994. |
LogWare III (optional software) |
Requirements: Microsoft® Windows® 2000 (SP4) or XP (SP2), (optional software) IBM compatible Intel Pentium® IV 1 GHz PC processor or higher, 512 MB RAM (1 GB or more recommended), 200 MB HDD space for installation (more is preferred for data storage), CD drive (required for installation) |
Related Products
-