TECHNO ELECTRIC Co.,Ltd.
TECHNO ELECTRIC Standard Power Supply (PSK 50W 2 Outputs)
Manufacturer: TECHNO ELECTRIC Co.,Ldt.
Product name: Standard Power Supply (PSK 50W 2 Outputs)
Features
- Input: AC100V (AC90–132V)
- Safety Standard: UL Standard
- Independent Control Method for Each Channel
Specification
Format name | PSK50-1212W | PSK50-1515W | PSK50-0524W | ||||
---|---|---|---|---|---|---|---|
CH | CH1 | CH2 | CH1 | CH2 | CH1 | CH2 | |
Rated Output Voltage | 12V | 12V | 15V | 15V | 5V | 24V | |
Rated Output Current | 2A | 2A | 1.5A | 1.5A | 3A | 1.5A | |
Total Output Capacity | 48W | 45W | 51W | ||||
Weight | 0.5(kg) | ||||||
Input conditions | Number of phases | 1φ | |||||
Rated input voltage
Tolerance |
AC100V (AC90-132V) | ||||||
frequency | 47Hz to 440Hz | ||||||
efficiency | 70% (TYP) | ||||||
Inrush current | 15A MAX (at rated input/output, +25℃) | ||||||
Input Current | 1.3A (TYP) (at rated input/output, +25℃) | ||||||
Noise Filter | Built-in | ||||||
Output Conditions | Voltage Variable Range | CH1±10%, CH2 (fixed) deviation ±4% | |||||
Ripple Noise | Output voltage x 1.0% + 50mV PP MAX (DC to 100MHz) | ||||||
Input fluctuation | Output voltage × 0.4% MAX | ||||||
Load Fluctuation | Output voltage x 0.8% MAX (0% to 100%) | ||||||
Temperature coefficient | Output voltage x 0.02%/℃ MAX (0℃~50℃) | ||||||
Drift | Output voltage x 0.5% + 15mV MAX (1H after power-on, 8H) | ||||||
Retention time | 20mS MIN ((at rated input/output, +25℃) | ||||||
Startup time | 200mS MAX (at rated input/output, +25℃) | ||||||
Additional Features | Overcurrent Protection | Drooping characteristics (automatic return) | |||||
Overvoltage Protection | Clover limiter type (CH1) Zener limiter type (CH2) | ||||||
Remote Control | – | ||||||
Remote Sensing | – | ||||||
General Terms | Temperature Operating Non-operating |
0℃~+71℃ -20℃~+85℃ |
|||||
Relative Humidity Operating Non-operating |
30 to 85% RH (no condensation) 30 to 95% RH (no condensation) |
||||||
Dielectric strength: Primary-secondary |
AC1500V 1 minute sensing current 10mA AC1500V 1 minute sensing current 10mA AC500V 1 minute sensing current 10mA |
||||||
Insulation resistance: Between primary and secondary (normal temperature and humidity) cases |
50MΩ MIN (DC500V) | ||||||
Leakage Current | 1.0mA MAX | ||||||
Structure | Vibration resistance | Total amplitude 0.75 mm, frequency 10 to 55 Hz, 1 minute cycle vibration in 3 directions for 2 hours each |
Related Products
-
TECHNO ELECTRIC Standard Power Supply (MP 3W Single Output)
-
TECHNO ELECTRIC ATM120T-□xxx AC Adapter 120 Watt Medical Series
-
TECHNO ELECTRIC Custom Power Supply for Traffic Control
-
TECHNO ELECTRIC ATM006T-Wxxx□ AC Adapter 6 Watt Medical Series
-
TECHNO ELECTRIC Standard Power Supply (MP 3W 2 Output)
-