Features

- Insulated tube is fabricated with high grade dual layer structure which has 30 times chemical expanded independent crosslinked polyethylene foam with thermal resistance up to 120 degrees.
- Seamless extrusion molding (1/4″ to 3/4″) helps to have minimum clearance between copper pipe and insulation tube so as to enhance dew condensation prevention.
- Embossed outer plastic film has high scratches resistance and wrinkle free characteristic.
- Soft annealed copper pipe is apply for 20m, 30m coil.
- Easy to bend and cut for installation efficiency.
- “Twin Dia” series come from pre-insulated pair coil for liquid and gas, can be separated easily by hand. Time and energy for installation can save a lot.
- Remaining length is print on insulation at 1 meter intervals.
- Thicker insulation (20mm) is available for higher prevention of dew condensation, which is ideal for concealed installation.
- Copper tube is complied with JIS H3300 C1220T.
Specifications
TD 20m Pair Coil
Model No. | Indication No.* | Copper Tube Size | Insulation Size | Package Q’ty |
---|
Outer Diameter | Wall Thickness | Outer Diameter | Wall Thickness |
---|
Metric | Imperial | Metric | Imperial | Metric | Imperial | Metric | Imperial |
---|
TD-2320-8 | 3 | 6,35 | 1/4″ | 0,8 | 0,031 | 24 | 0,945 | 8 | 0,315 | 1 |
9,52 | 3/8″ | 0,8 | 0,031 | 27 | 1,063 | 8 | 0,315 |
TD-2320W | 3 | 6,35 | 1/4″ | 0,8 | 0,031 | 24 | 0,945 | 8 | 0,315 | 2 |
9,52 | 3/8″ | 08 | 0,031 | 27 | 1,063 | 8 | 0,315 |
TD-2420 | 2 | 6,35 | 1/4″ | 0,8 | 0,031 | 24 | 0,945 | 8 | 0,315 | 1 |
12,70 | 1/2″ | 0,8 | 0,031 | 34 | 1,339 | 10 | 0,394 |
TD-3520 | 2 | 9,52 | 3/8″ | 0,8 | 0,031 | 27 | 1,063 | 8 | 0,315 | 1 |
15,88 | 5/8″ | 10 | 0,039 | 37 | 1,457 | 10 | 0,394 |
TD-3620Z | 2 | 9,52 | 3/8″ | 0,8 | 0,031 | 27 | 1,063 | 8 | 0,315 | 1 |
19,05 | 3/4″ | 1,2 | 0,047 | 41 | 1,614 | 10 | 0,394 |
TD 30m Pair Coil
Model No. | Indication No.* | Copper Tube Size | Insulation Size | Package Q’ty |
---|
Outer Diameter | Wall Thickness | Outer Diameter | Wall Thickness |
---|
Metric | Imperial | Metric | Imperial | Metric | Imperial | Metric | Imperial |
---|
TD-2330 | 3 | 6,35 | 1/4″ | 0,8 | 0,031 | 24 | 0,945 | 8 | 0,315 | 1 |
9,52 | 3/8″ | 0,8 | 0,031 | 27 | 1,063 | 8 | 0,315 |
TD-2430 | 2 | 6,35 | 1/4″ | 0,8 | 0,031 | 24 | 0,945 | 8 | 0,315 | 1 |
12,70 | 1/2″ | 0,8 | 0,031 | 34 | 1,339 | 10 | 0,394 |
TDS 20m Pair Coil- Thicker Insulation
Model No. | Indication No* | Copper Tube Size | Insulation Size | Package Q’ty |
---|
Outer Diameter | Wall Thickness | Outer Diameter | Wall Thickness |
---|
Metric | Imperial | Metric | Imperial | Metric | Imperial | Metric | Imperial |
---|
TDS-2320A | F 3. | 6,35 | 1/4″ | 0,8 | 0,031 | 28 | 1,102 | 10 | 0,394 | 1 |
9,52 | 3/8″ | 0,8 | 0,031 | 51 | 2,008 | 20 | 0,787 |
TDS-2420A | F 2. | 6,35 | 1/4″ | 0,8 | 0,031 | 28 | 1,102 | 10 | 0,394 | 1 |
12,70 | 1/2″ | 0,8 | 0,031 | 54 | 2,126 | 20 | 0,787 |
TDS-3520A | F 2. | 9,52 | 3/8″ | 0,8 | 0,031 | 31 | 1,220 | 10 | 0,394 | 1 |
15,88 | 5/8″ | 1,0 | 0,039 | 57 | 2,244 | 20 | 0,787 |
TD-t10 20m Pair Coil
Model No. | Indication No.* | Copper Tube Size | Insulation Size | Package Q’ty |
---|
Outer Diameter | Wall Thickness | Outer Diameter | Wall Thickness |
---|
Metric | Imperial | Metric | Imperial | Metric | Imperial | Metric | Imperial |
---|
TD-2320-tW | 3 | 6,35 | 1/4” | 0,8 | 0,031 | 28 | 1,102 | 10 | 0,394 | 1 |
9,52 | 3/8” | 0,8 | 0,031 | 31 | 1,220 | 10 | 0,394 |
TD-2320-H0W | 3 | 6,35 | 1/4″ | 0,8 | 0,031 | 28 | 1,102 | 10 | 0,394 | 2 |
9,52 | 3/8” | 0,8 | 0,031 | 31 | 1,220 | 10 | 0,394 |
TD-2420410 | 2 | 6,35 | 1/4″ | 0,8 | 0,031 | 28 | 1,102 | 10 | 0,394 | 1 |
12,70 | 1/2″ | 0,8 | 0,031 | 34 | 1,339 | 10 | 0,394 |
TD-3520-H0 | 2 | 9,52 | 3/8” | 0,8 | 0,031 | 31 | 1,220 | 10 | 0,394 | 1 |
15,88 | 5/8” | 1,0 | 0,039 | 37 | 1,457 | 10 | 0,394 |
TD-3620-tW | 2 | 9,52 | 3/8″ | 0,8 | 0,031 | 31 | 1,220 | 10 | 0,394 | 1 |
19,05 | 3/4″ | 1,2 | 0,047 | 41 | 1,614 | 10 | 0,394 |
SD 20m Single Coil
Model No. | Indication No* | Copper Tube Size | Insulation Size | Package Q’ty |
---|
Outer Diameter | Wall Thickness | Outer Diameter | Wall Thickness |
---|
Metric | Imperial | Metric | Imperial | Metric | Imperial | Metric | Imperial |
---|
SD-220A <£S> | 3 | 6,35 | 1/4″ | 0,8 | 0,031 | 28 | 1,102 | 10 | 0,394 | 3 |
SD-320A | 3 | 9,52 | 3/8″ | 0,8 | 0,031 | 31 | 1,220 | 10 | 0,394 | 3 |
SD-420 | 2 | 12,70 | 1/2″ | 0,8 | 0,031 | 34 | 1,339 | 10 | 0,394 | 2 |
SD-520 | 2 | 15,88 | 5/8″ | 1,0 | 0,039 | 37 | 1,457 | 10 | 0,394 | 1 |
SD-620Z | 2 | 19,05 | 3/4″ | 1,2 | 0,047 | 41 | 1,614 | 10 | 0,394 | 1 |
SDS 20m Single Coil • Thicker Insulation
Model No. | Indication No.* | Copper Tube Size | Insulation Size | Package Q’ty |
---|
Outer Diameter | Wall Thickness | Outer Diameter | Wall Thickness |
---|
Metric | Imperial | Metric | Imperial | Metric | Imperial | Metric | Imperial |
---|
SDS-220 | 3 | 6,35 | 1/4″ | 0,8 | 0,031 | 48 | 1,890 | 20 | 0,787 | 1 |
SDS-320 | 3 | 9,52 | 3/8″ | 0,8 | 0,031 | 51 | 2,008 | 20 | 0,787 | 1 |
SDS-420 | 2 | 12,70 | 1/2″ | 0,8 | 0,031 | 54 | 2,126 | 20 | 0,787 | 1 |
SDS-520 | 2 | 15,88 | 5/8″ | 1,0 | 0,039 | 57 | 2,244 | 20 | 0,787 | 1 |
SDS-620Z | 2 | 19,05 | 3/4″ | 1,2 | 0,047 | 61 | 2,402 | 20 | 0,787 | 1 |