MAEDA KOKI FITVM Type Flow Indicator

Manufacturer: Maeda Machinery Research Institute Ltd.
Model : FITVM type

Features

  • It distribute a fluid and can see the flow, too.
  • It can distribute a fluid between each branch pipe.
  • It can produce it from a distribution branch pipe of two to 11 from a distribution branch pipe.
  • It can confirm fluid flow by viewing.
  • With the flow quantity adjustment valve using the indication red line of the taper transparence pipe as an indication the position of the ball.
  • It can adjust the valve of each branch pipe while seeing it.
  • With the flow switch, it detect fluid flow and let it is ON, or a switch be off with flow quantity of the designation.
  • ※The switch is rigid (the set point change from a trace is not possible)
  • ※In the case of an order, an estimate □Please appoint the inside of this.
The number of branch pipes □Book
(2-11)
 FITVM-
Branch pipe connection method
(φ 6, φ 8, φ 10)
(Rc1/8,Rc1/4,Rc3/8)
(R1/8,R1/4,R3/8)
Point of contact method
OFF/ON
Flow quantity of each branch pipe
L/min
Operation flow quantity of the switch
L/min
Kind of the oil
(or viscosity  cSt of the oil)
  • An example: Kind ISOVG32 of the operation flow quantity 0.3L/min oil of the flow quantity 1L switch of each 8FITVM-Rc1/8-OFF branch pipe
  • ※The point of contact method, please appoint OFF method or ON method.
  • When OFF method, fluid does not flow; the point of contact is OFF.
  • When ON method, fluid does not flow; the point of contact is ON.

Standard specifications (FITV part) 

Holder
FC20
Coupling
C3604
 Transparent taper pipe
Acrylic
Ball
SUJ or nylon
 Adapter
C3604
 O ring
Nitrile rubber
Spring
SUS304
Communication pipe
C3604
 Miniature valve
BC

Standard specifications (flow switch part) 

Fluid
Oil 
Operation flow quantity
Please appoint it with a flow quantity level less than 1/3 of the smallest specifications flow quantity if possible.
Connection
The reference mentioned above 
Heat-resistant temperature
A maximum of 60 degrees Celsius
Withstand pressure
1MPa
The use of maximum voltage
DC, AC 300V 
Use of maximum electric current
DC, AC 0.5A 
Point of contact capacity
50VA 
Materials
Transparent pipe
Acrylic
– 
Protective cover
BC (gunmetal)
– 
Coupling
C3604 (brass)
– 
Spring
SUS304
– 
Float with magnet
Aluminum
– 
 O ring
Nitrile rubber
– 
 Lead switch
Marketing product 
– 
 Lead (authentic sample 200mm)
Marketing product 
Designation of the length of the lead is possible. 

Flow switch precautions 

1. Attention in the magnetic influence

  • Please use the lead switch for a switch acting with magnetism at the place that is not affected by the magnetic field.
  • When magnetic bodies such as the iron exist in the vicinity of the lead switch, it causes the malfunction.

2. Attention in the electrical connection

  • So that, as for the flow switch, an overcurrent does not flow in a lead switch for causes such as the ground connection defectiveness
    Please be careful about connection.
  • Please use the flow switch as a warning analyzer if possible.
    When you use it in conjunction with other electric apparatuses, please deal with influence when malfunction occurred after consideration enough.
  • When the use voltage, the use electric current hold it in check as small as possible and use it, the life of the lead switch gets longer.
    (usually possible use of approximately 1 million times of switch operation under the 100V0.5A situation)

3. Attention about the switch operation by a temperature change, the viscosity change of the oil

  • The operation flow quantity of a case and the switch which a switch does not operate with flow quantity of the setting when temperature, viscosity of the oil change. It may change.

REQUEST QUOTATION

PAYMENT

payment-methods

 

TOOLS & EQUIPMENT

Lifting
Eagle Clamp | Eagle Jack | Elephant | Endo Kogyo
Japan Clamp | Kanetec | Jung | KITO | Katsuyama Kikai
Kondotec | Miki Netsuren | Sanei Seiki | Taiyo

Hand Tools
Bix | Miyakawa | Nakatani Kikai | Ogura | Osakada Tool
Super Tool | TONE | Yutani

Tape
Kamoi | Kikusui | Misuzu | Nirei | Okamoto | Taiho | Teraoka

Measurement
Hasegawa | Kawaki | Kett | KGK | Line Seiki | Nagano Keiki
Niigata Seiki | Obishi Keiki | RSK | Ryoden Shonan | Sanko
Sanwa Supply | Showa Seisakusho | Showa Sokki
SK Sato | Tokyo Keiso | Tokyo Sokushin

Safety Tools
Fujii Denko | Shigematsu | Titan

Welding
Asahi Weldex | Daihen | Koike | Nissan Tanaka

Drilling
Dijet | Kansai Kogu | Nitto Kohki | Okazaki Seiko | Takeda

Chemical
Cemedine | DaitoNippon Grease | Taseto

Other Tools
Hammer Caster | Kitagawa | Matsuda Seiki | Misuz | Sanritsu
Sanyutec | Shizuoka Seiki | Toyo Kensetsu Kohki | Yamamoto
Yamari

PLANT FACILITIES

Facilities
Acokk | Bunkaboeki | Horiuchi | Konan | Murakoshi
Murakoshi Industries | Nesstech | Nihon Flux | Nikkin Flux
NFK | Omega System | Organo | Taiyo Parker | Toyo Mic

Pump
Dynaflo | Ebara | Honda Kiko | KyowaMusashino
Tsurumi

Valve
Astam | Kyowa Iron | Nachi | Nippon Daiya | Sawada
Wasino Kiki | Yoshitake

Electricity
Arkon | Asahi Bagnal | Gentos | Iwasaki | Kokosha | U_RD

CONSTRUCTION

Concrete Work
Daia | EXEN | Japan Life | Mikasa | Okasan Kiko | Taiheiyo

Railway Work
Kyoei | Sanwa Tekki | Teikoku | Toko

Scaffolding
Bullman | Okabe | Rikiman | Tsugaru

High Tension Bolt
Dong Ah | KPF | Nippon Steel Bolten | Nippon Fastener

Bolt & Nut & Washer
Hard Lock | Kishu Fastener | Matsukin | Mori Kozai
Nakaumi | Naniwa | Ogawa | Otani | Sudo | Toneji

STEEL MATERIAL

Steel & other Material
Dongil | JIS Standard | DSR | Sumitomo Wire | Winoa IKK

Pipe
Benkan

Return Top