Multi CTF-50DC-U24V AC and Reciprocal (PWM, Inverter, etc.)

Manufacturer: Multi Measuring Instruments Co., Ltd
Model: CTF-50DC-U24V

Features

DC/AC 50A/DC~10kHz for
DC/Inverter Current Measurement of
Terminal Feeder

Specifications

Rated currentAC/DC 50A
Applicable currentAC/DC ±2.5~±50A
Maximum allowable currentAC/DC 75Acontinuous
Output Voltage±4V/Rated Current (9V±4V between OUT-0V, 0V±4V between OUT-GND)
Application frequencyDC ~10kHz
Wire diameter that can be installedMaximum φ14.5mm
accuracy±1.0%/Rated Current
Supply voltage+24V (Single Supply)
Current ConsumptionApprox. 7mA
Temperature coefficient±0.1% / ℃
Operating Circuit VoltageAC/DC 500V or less (but covered wires)
Withstand voltageAC 2000V / 1 minute (between outer case ~ output)
Insulation resistanceDC 500V/100MΩ or more (between exterior case ~ output)
Temperature and humidity-10~60°C 80%RH or less However, no condensation
Reference StandardsRoHS compliant
Output Leads33cm (Red: +24V, Black: 0V, White: Output OUT, Green: Output GND)
Dimensions and weightW29.5×H55×D30.5mm Approx. 70g
cautionThe output may be affected by various environments, so it is recommended to use it at least 5% of the rated level.

REQUEST QUOTATION

PAYMENT

payment-methods

Return Top