Features
CT window diameter φ80mm for signal injection Applicable frequency approx. 4300Hz
Specifications
| Nominal Current Ratio | 203:1 |
|---|---|
| Application frequency | Approx. 4300Hz |
| Wire diameter that can be installed | Max φ80mm |
| Excitation impedance | Approx. 2kΩ |
| Withstand voltage | AC 2200V/1 min (between exterior case ~ output) |
| Insulation resistance | DC 500V/100MΩ or more (between exterior case ~ output) |
| Temperature and humidity | -10~60°C 80%RH or less (but not condensing) |
| Applicable Standards | RoHS compliant |
| Dimensions and weight | W123.2×H240.3×D53mm approx. 600g |
Related Products
-

Multi MIS-PVS Solar Panel Insulation Resistance Meter (with Insulation Deterioration Function
-

Multi M-240+ AC/DC Mini Clamp Meter
-

Multi Board‐mounted excitation leakage current sensor
-

Multi LS-7S 4G LTE Compatible Io Isolation Monitoring System
-

Multi M-220 Mini Clamp Meter
-

Multi MLA-200 Insulation Monitoring Device