Simotec Push Latch, No Magnet Type (S)

Manufacturer: Shimonishi Giken Kogyo Co., Ltd
Product name: Push Latch, No Magnet Type (S)

Features

  • ・A fastener latch that allows push-to-lock and push-to-open operation with a single touch on doors used in home appliances and audio equipment.
  • One-touch operation with no handles or knobs required.
    The door opens with a gentle push of your finger, and when closing, the arm firmly catches and holds the door in place.
  • -No magnet used

Purpose of use

・As a fastener for opening and closing doors on cabinets, measuring instruments, information and communication equipment, furniture, home appliances, etc.

Specification

RoHS compliant

Part NumberSS0053-A01A
size
Weight1.0g
materialPOM resin
durability50,000 operations at room temperature (locking/unlocking counts as one operation)
Breaking LoadLocked tensile load: 3.4 kgf (33.32 N)
Heat Resistance Test50,000 operations after 65℃ 65% x 7 hours treatment
Heat cycle test 50,000 operations after 15 cycles of 65°C 65% x 3 hours to -20°C x 3 hours
Cold resistance test-20℃ x 7 hours after treatment, 50,000 operations
Holding force with door support1.0 to 1.5 kgf (9.8 to 14.7 N)
Slide catch pushing force0.45±0.1kgf (4.41±0.98N)
Slide catch release force0.35±0.1kgf (3.43±0.98N)
Removal force after push catch is attached6kgf (58.8N) or more

Usage example

Push Latch, No Magnet Type (S)

  • ・Please refer to the “Example of Use” diagram above when creating the holder shape and the body mounting part. Note that the holding power will vary depending on the holder shape and thickness.
  • – The center misalignment between the receiver and catch should be 0.2 mm or less.
  • – When using on a door, the rotation radius from the center of rotation to the receiving center should be 30 mm or more.
    When using vertically (rotating 90°), the radius should be 40 mm or more.
  • – The structure must ensure an unlock stroke of 1.5 mm.
  • -Please install a stopper at the unlock position.

Usage notes

  • When used in high temperature, high humidity (where water or other liquids are present), dusty or dirty places, the strength and holding power may decrease.
  • Do not use on doors where load is applied to the catch when locked.
  • Use a structure that does not apply the door’s own weight when locked.
  • ・Do not use on doors or structures that have been loaded with springs, etc.
    If the load on the door receiving part is greater than the force of the spring built into the push latch, or if the friction resistance of the door rotation part is great, the latch will not be able to be released from the locked state.
  • Do not forcefully remove the receiver or door when it is locked.
  • -Do not use in a structure that corrects the door when locked.
  • Do not use multiple units on the door.

REQUEST QUOTATION