Features

1 Single or double dual use valve
● With the F series 2-position valves, you can use a manual override to select either the single solenoid valve or the double solenoid valve function.

2 Employs dual use fittings
● Koganei’s unique dual-use fittings can be connected to two different types of tubes with differing outer diameters.
● No need to waste time selecting fittings based on the tube size.

Mountable tube sizes:
F10 series: φ4 and φ6
F15 series: φ6 and φ8
F18 series: φ8 and φ10
3 Allows the fitting block to be changed for either base piping or direct piping
● Since the direction of the fitting blocks can be changed after purchase, the user is free to change the piping direction.

Specifications

ItemF18T0F18T3F18T1F18T4F18T2F18T5
MediaAir
Operation typeSonic conductance C dm³/(s·bar) Note1
Flow rate characteristicsEffective area [mm²]: 18 [1.0]
Port sizeM5 × 0.8, 10-32UNF, dual use fitting for φ8 and φ10, Rc1/4, NPT1/4
LubricationNot required
Operating pressure rangeMain valve: 0.15 ~ 0.7 MPa [22 ~ 102 psi]
External pilot: 0.2 ~ 0.7 MPa [29 ~ 102 psi]
0.2 ~ 0.7 MPa [29 ~ 102 psi]0.2 ~ 0.7 MPa [29 ~ 102 psi]0.2 ~ 0.7 MPa [29 ~ 102 psi]0.2 ~ 0.7 MPa [29 ~ 102 psi]0.2 ~ 0.7 MPa [29 ~ 102 psi]
Proof pressureMPa [psi]: 1.05 [152]MPa [psi]: 1.05 [152]MPa [psi]: 1.05 [152]MPa [psi]: 1.05 [152]MPa [psi]: 1.05 [152]MPa [psi]: 1.05 [152]
Response time12VDC, 24VDC: 25/35 or below
100VAC: 25/35 or below
12VDC, 24VDC: 25/35 or below
100VAC: 25/35 or below
12VDC, 24VDC: 25/35 or below
100VAC: 25/35 or below
12VDC, 24VDC: 25/35 or below
100VAC: 25/35 or below
12VDC, 24VDC: 25/35 or below
100VAC: 25/35 or below
12VDC, 24VDC: 25/35 or below
100VAC: 25/35 or below
ON/OFFAC100V, AC200V: 15/70 or belowAC100V, AC200V: 15/70 or belowAC100V, AC200V: 15/70 or belowAC100V, AC200V: 15/70 or belowAC100V, AC200V: 15/70 or belowAC100V, AC200V: 15/70 or below
Maximum operating frequencyHz: 50
Minimum time to energize for self holding5
Operating temperature range (atmosphere and media)°C [°F]: 5 ~ 50 [41 ~ 122]
Shock resistanceLateral direction: 1373.0 [140.0] (Axial direction: 196.2 [20.0])Lateral direction: 1373.0 [140.0] (Axial direction: 196.2 [20.0])Lateral direction: 1373.0 [140.0] (Axial direction: 196.2 [20.0])Lateral direction: 1373.0 [140.0] (Axial direction: 196.2 [20.0])Lateral direction: 1373.0 [140.0] (Axial direction: 196.2 [20.0])Lateral direction: 1373.0 [140.0] (Axial direction: 196.2 [20.0])
Mounting directionAny
Massg [oz.]: 300 [10.58]g [oz.]: 300 [10.58]g [oz.]: 300 [10.58]g [oz.]: 300 [10.58]g [oz.]: 300 [10.58]g [oz.]: 300 [10.58]

 