Koganei Blow Type Standard Type ELK Series

Manufacturer: KOGANEI CORPORATION

Features

  • Advanced Ion Control: First, these units utilize a high-frequency AC type system. Consequently, they achieve an outstanding ion balance of $\pm$15V or less.

  • Rapid Performance: Furthermore, the technology enables rapid static removal. Specifically, it neutralizes charges in 0.5 seconds or less.

  • Versatile Application: Additionally, users can choose from 31 different nozzle types. Therefore, the device handles everything from pinpoint targets to wide workpieces.

  • Simplified Maintenance: Moreover, the design includes a one-touch discharge needle unit. This allows for simple detachment and attachment during routine cleaning.

  • Operational Safety: Similarly, the series is fully CE marking compliant. To aid monitoring, it features four distinct LED indicators for power, high voltage, and alarms.

  • Efficient Powering: Finally, the system operates on a standard 24VDC input. Meanwhile, it generates a steady output of approximately 2 kV for effective ionization.

Specifications

Item \ ModelDTY-ELK01 (Standard Type)DTY-ELK01-S (Low Air Consumption Type)DTY-ELK01-L (Low Particle Generation Type)
Power supply24VDC ±5%
Consumption currentmAApproximately 70
Output voltagekVApproximately 2 (high-frequency type)
IndicatorsPOWER LED (green)Lights while power is on
H.V LED (blue)Lights during discharge
CHECK LED (yellow)Lights when a discharge abnormality occurs (H.V LED off)
ALARM LED (red)Lights when a machine abnormality occurs (H.V LED off)
OutputContact output when CHECK LED or ALARM LED is lighted (24VDC 50 mA MAX. open drain)
Ionizer ON/OFF control inputDischarge stop by short circuit with 0V (no voltage input, internal drop voltage of 0.5V or less)
Ion balanceVWithin ±15 (standard nozzle; 50 mm [2 in.] from nozzle tip; supply air pressure: 0.3 MPa [44 psi.])
Static charge removal timeNote 1seconds0.5 or less0.8 or less0.5 or less
Ozone generation amountppm0.03 or less (standard nozzle; 300 mm [11.8 in.] from nozzle tip; supply air pressure: 0.3 MPa [44 psi.])
Particle generation amountNote 2particles50 or less
MediumAir (clean air, water vapor and oil removed)
Operating air pressure rangeMPa [psi.]0.05 ~ 0.5 [7 ~ 73]
Expended air flow rateNote 3ℓ/min [ft3/min] (ANR)260 [9.2]60 [2.1]260 [9.2]
Massg [oz.]60 [2.12]Note 475 [2.65]Note 566 [2.33]Note 4
Operating environmentIndoors: 0 to 40°C [32 to 104°F], 15 to 65% RH (non-condensation)
AccessoriesPower and signal cable (2 meters), bracket

 