Venn RP-10 type pressure reducing valve (for steam)

Manufacturer: Venn Co., Ltd.
Model: RP-10 type

Features

  • This is a pilot-type pressure reducing valve for high-pressure steam.
  • It is designed to safely lower steam pressure.
  • In addition, it supports a maximum pressure reduction ratio of 20:1.
  • As a result, it operates stably even under high pressure differences.
  • Moreover, the face-to-face dimensions match the former RP-2H pressure reducing valve.
  • At the same time, the weight is reduced by about 40%.

Specifications

Product codeRP10-C
typeMade of cast steel
Nominal diameter15-150 (1/2-6)
Applicable fluidsteam
Fluid temperature250 ° C or less
Primary side applied pressure3.0MPa or less
Secondary adjustment pressure range0.03 ~ 0.8MPa
Maximum decompression ratio20: 1
Minimum differential pressure before and after the valveNominal diameter 15 ~ 80: 0.05MPa, Nominal diameter 100 ~ 150: 0.07MPa
Deadline boost0.02MPa or less
offsetWithin 0.02MPa (Secondary adjustment pressure 0.03 to 0.035MPa) Within 0.03MPa (Secondary adjustment pressure over 0.035 0.07MPa) Within 0.05MPa (Secondary adjustment pressure over 0.07 0.8MPa)
Allowable leakage amount0.05% or less of the rated flow rate
End connectionJIS 30K RF flange
Material bodySCPH
Material Valve bodySUS
Material Valve seatSUS
Material Piston / CylinderSUS
Handle or cap colorGreen
Mounting postureUpright mounting on horizontal piping