Koken 1180 Series Dust Mask

Manufacturer: KOKEN LTD.
Model: 1180 Series

Important points when wearing a mask

Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself while wearing a dust mask, both the performance of the filter and the “tight seal” (fit) between the mask and your face are critical.

1. Filter Technology with High Particle Collection Efficiency

Mighty (Uni) Micron Filter
Using unique technology, wool fibers are electrostatically charged, allowing electrostatic force to draw particles to the fiber surface. This is the primary mechanism for capturing particles. A high-density fiber structure is unnecessary, successfully integrating the two contrasting features: “high collection efficiency” and “low inhalation resistance.” It consistently maintains the highest standard of performance and quality, making it an excellent long-term filter solution.

Applied products are on P.4 ~ 6, P.11

Alpha Ring Filter

Increasing the fiber density of the filter enhances collection efficiency. To meet airflow resistance standards, paper filters traditionally require an expanded surface area.

For the first time in Japan, ultra-fine fibers were formed into pristine circular shapes in a single process, creating the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.

Applied products are from page P.8 to P.11

Dust Respirator Standards

In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.

Dust Respirator StandardsIn addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.

Note: The table below is excerpted from the “Dust Respirator Standards”.

Replaceable Dust RespiratorIsolation Type Dust Respirator
Direct-Connection Type Dust Respirator
Disposable Dust Respirator
Test ParticlesTypeNaCl (Sodium Chloride)DOP (Dioctyl Phthalate)
Particle Size0.06 μm to 0.1 μm0.15 μm to 0.25 μm
Concentration50mg/m³ or less100mg/m³ or less
Test Flow Rate85 ℓ/min85 ℓ/min
Particle Collection Efficiency
(Continuous measurement; must meet values in the right column)
For NaCl particles
Load up to 100mg
For DOP particles
Load up to 200mg
Replaceable
Type
RS180.0% or higherRL180.0% or higher
RS295.0% or higherRL295.0% or higher
RS399.9% or higherRL399.9% or higher
Disposable
Type
DS180.0% or higherDL180.0% or higher
DS295.0% or higherDL295.0% or higher
DS399.9% or higherDL399.9% or higher
Inhalation Resistance
(Test Flow Rate 40 ℓ/min)
Replaceable TypeDisposable Type
RS1 RL170Pa or lessDS1 DL160Pa or less (45Pa or less)
RS2 RL280Pa or lessDS2 DL270Pa or less (50Pa or less)
RS3 RL3160Pa or lessDS3 DL3150Pa or less (100Pa or less)
Exhalation Resistance
(Test Flow Rate 40 ℓ/min)
Replaceable TypeDisposable Type
RS1 RL170Pa or lessDS1 DL160Pa or less (45Pa or less)
RS2 RL270Pa or lessDS2 DL270Pa or less (50Pa or less)
RS3 RL380Pa or lessDS3 DL380Pa or less (100Pa or less)

Values in ( ) are for products without an exhalation valve.

Exhalation Valve AirtightnessExhalation valve leak test– Internal pressure must drop immediately during suction.
– Time for internal pressure to return to normal must be 15 seconds or more.
CO2 Concentration IncreaseMeasured using a test headform and artificial lung. The difference in CO2 concentration in inhaled air with and without the mask must be 1.0% or less.
Dead SpaceValue calculated from the CO2 Concentration Increase Test.
Inhalation Resistance IncreaseTest ParticlesNaCl (Sodium Chloride)
Test Flow RateAfter dust accumulation at 85 ℓ/min, measurement is taken at 40 ℓ/min.
Dust Accumulation Amount100mg

Test Particles & Efficiency Disposable / Replaceable

SLClassification
(Efficiency)
Test particle: Solid NaClTest particle: Liquid DOP
RReplaceable Dust RespiratorRS1RL1Class 1 (≥ 80.0%)
RS2RL2Class 2 (≥ 95.0%)
RS3RL3Class 3 (≥ 99.9%)
DDisposable Dust RespiratorDS1DL1Class 1 (≥ 80.0%)
DS2DL2Class 2 (≥ 95.0%)
DS3DL3Class 3 (≥ 99.9%)

High Efficiency Filter + Face-Friendly Surface

2. Surface Engineering for a Better Facial Fit

Even if a dust mask has a high collection efficiency filter, it is useless if dust leaks in through the facepiece seal. The primary cause of leakage is the “gap at the contact area when wearing the mask.” We consider the fit of the mask to be as important as the filter performance. Therefore, our company has developed technology to enhance the airtightness of the facial contact area.

Silicone Facepiece
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and easily adapts to body movements, ensuring wearing comfort and stability during use.

HAWC Harness
The harness design ensures high tension and maximizes the “suction” effect when wearing the mask, guaranteeing an airtight seal on the face.

Freeposition Under-Chin
The special shape of the facial contact area prevents dust entry. The nose section is adjustable for different sizes, ensuring a perfect fit for a wide range of facial dimensions (see image below).

Fit Status of the Freeposition Under-Chin Facepiece
(Cross-sectional simulation to show the contact position between the mask and the chin).

For large faces:
Uses the outer section of the mask to adjust the fit around the chin.
For small faces:
Uses the inner section of the mask to adjust the fit around the chin.
FF LipWearing SafetyInternal Fit Checker
Designed for various face shapes; the cushion naturally fits your face.Utilizes a 3D poly-band harness that matches head shapes to enhance the feeling of fit and seal.Built-in fit checker allows for seal checks at any time (for models 1005, 1010A, 1015, 1180 series).

Harness Types
Please replace the harness regularly.

Sakaki – Model 1180-05

Double-layer bonnet structure protecting the exhalation valve.

RL2 Classification
Built-in Fit Checker
Compact, lightweight model – 99 g
Size S available

Model Assay Certificate: TM538
Assigned Protection Factor: 10

Can be used as a gas mask (G-7 configuration)
(Absorbent canisters sold separately)

Gas Mask Certificate: TN382

Option: Moisture Sponge Type A

  • Fit Checker (rapid seal test)
  • Under-Chin cushion
  • Silicone facepiece
  • Size S available
Particle Collection Efficiency
95.0% or higher
(Average 98.0%)
Inhalation Resistance
80Pa or less
(Average 72Pa)
Exhalation Resistance
45Pa or less
(Average 25Pa)
Inhalation Resistance Increase

(Average 123Pa)
Weight
114g or less
(Average 99g)
HarnessRB Type

Consumable Parts:

  • Inhalation valve: Small 03 type
  • Exhalation valve: T-7 type

Sakaki – Model 1180C-05

Equipped with Activated Carbon Filter

RL2 Classification
Suitable for organic odors and ozone below permissible levels
Built-in Fit Checker

Warning: Not a dedicated gas mask for high concentrations.

Model Assay Certificate: TM539
Assigned Protection Factor: 10

Option: Moisture Sponge Type A

  • Fit Checker (rapid seal test)
  • Under-Chin cushion
  • Silicone facepiece
  • Size S available
  • Low inhalation resistance
  • Activated carbon filter
Particle Collection Efficiency
95.0% or higher
(Average 98.8%)
Inhalation Resistance
80Pa or less
(Average 71Pa)
Exhalation Resistance
45Pa or less
(Average 27Pa)
Inhalation Resistance Increase

(Average 133Pa)
Weight
113g or less
(Average 98g)
HarnessRB Type

Consumable Parts:

  • Inhalation valve: Small 03 type
  • Exhalation valve: T-7 type

▲ Shared Replacement Parts for 6 Models (1181R-03, 1121R-08, 1191SD-03, etc.)

  • Inhalation valve: circular type
  • Moisture sponge: oval type

Replacement Filters · Optional Accessories

LAS-52 (for 1181R)LAS-52C (for 1181RC)LAS-1 (for 1121R, 1121RX, 1191SD, 1191D)LAS-51 (for 1180)LAS-51C (for 1180C)KBC Filter for 1121 / 1191
(Ozone & organic odor removal – pack of 5)
For: 1121R / 1121RX / 1191SD / 1191D / 1122R
(Optional)
Fit Test Device – Type F
For: 1181R, 1181RC, 1121R, 1121RX, 1191SD, 1191D
(Optional)
Screw-in – Pack of 2Screw-in – Pack of 2Pack of 2Screw-in – Pack of 2Screw-in – Pack of 2
  • Under Chin: Specialized curve enhances seal at facial contact points.
  • Silicone: Soft, skin-friendly material provides a comfortable wearing feel. Facepiece seal uses silicone.
  • Size S Available: Small size option for users with petite faces.
  • Low Resistance: Uses Alpha Ring filter for low breathing resistance, allowing for long-duration work.
  • Speaking Diaphragm: Allows communication and instructions to be heard without removing the mask.
  • Activated Carbon: Effectively removes low-concentration ozone using carbon-treated filters.
  • Micron: High-performance electrostatic filter compliant with RL classification.
  • Fit Checker: Perform a manual seal test by simply operating the lever.

Double-Layer Bonnet Structure

The exhalation valve is shielded inside the bonnet from external factors like wind. Exhaled air accumulated in the upper bonnet acts as a buffer (barrier), preventing direct external impact and protecting the valve. This significantly improves exhalation valve performance and stability under real usage conditions.

Note on Replacement
Always replace filters and consumable parts according to recommended schedules.

REQUEST QUOTATION

PAYMENT

payment-methods

LINK

koueigroup-banner1