Suntest IRDS-SA. Strain Gauge Conditioner Module

Manufacturer: Suntest Co.,Ltd
Model: IRDS-SA

This is a slave module for measuring load cell or pressure transducer of IRD series. Possible to select 1 or 2 channels, and to connect with load cell or pressure transducer of 120Ω-1kΩ.
Parameters can be changed through IRD master module over host industrial network or the dedicated Windows software (IRD Manager).

  • IRDS-SA10 : one channel type
  • IRDS-SA20 : two channels type
  • The data is transferred to the industrial network through IRD master module. (CC-Link, EtherNet/IP, PROFIBUS)
  • Possible to have analogue or digital output from other slave modules in IRD system. (IRDS-AIO, AO4 and DO)
  • Giving bridge voltage 2V or 5V to load cell and converting voltage output from the load cell to digital data.
  • Possible to preset through IRD master module or host industrial network.
  • With scaling full voltage range (no matter which bridge voltage) with 16bit, it is not necessary to make calculation for each unit even the bridge voltages are different.
  • In case of using 6-wires load cell with long cable, compensating the bridge voltage o load cell and keep it stable by feedback the given bridge voltage.
  • Thanks to ratiometric measurement based on GND, no influence from temp. variation and time variation.
  • Possible to set upper and lower limit output.
  • Self diagnosis function : internal IC error, cable error
  • RoHS compliant

Model

IRDS (1) – SA (2) (3) – (4)

(1) series
IRDS : IRD slave module

(2) module function
SA      : Strain gauge conditioner module

(3) Number of sensors

10: one channel
20: two channels

(4) special specification code

blank: standard
others: customer’s special option

Occupied memory block and input / output bytes

Module seriesMemory blockInput byteOutput byte
IRDS-SA41616

Specifications

ItemsIRDS-SA10IRDS-SA20
Sensor
detection
number of sensorone channeltwo channels
connectable
transducer
4-wire or 6-wire strain gauge transducer
Load-cells or pressure transducer
bridge voltageDC 2V or 5V (can be changed by user)
Max. 60mA for each axis
max. analogue
input
±18mV
(up to ±3.5mV/V transducer in 5V bridge voltage)
(up to ±8.75mV/V transducer in 2V bridge voltage)
resolution0.6μV (16bit for full scale)
update cycle0.2ms
zero drift≤0.1μV/°CRTI
gain drift≤±10ppm/°C
non-linearity≤0.01%FS
low pass filter10Hz / 25Hz / 50Hz / 100Hz / 500Hz / 1kHz / None
(1 degree IIR low-pass)
preset rangeWithin any range (digital preset)
IsolationspecificationThe inside circuit is isolated from power supply.
Withstand voltage 500VAC for one minute.
Power supplyratingDC24V (±10%)  100mA supplied by IRDM (master module)

REQUEST QUOTATION

PAYMENT

payment-methods

LINK

koueigroup-banner1
koueigroup-banner1

Return Top