| Module series | Memory block | Input byte | Output byte |
|---|---|---|---|
| IRDS-SA | 4 | 16 | 16 |
Suntest
Suntest IRDS-SA. Strain Gauge Conditioner Module

Manufacturer: Suntest Co.,Ltd
Model: IRDS-SA
This is a slave module for measuring load cell or pressure transducer of IRD series. Possible to select 1 or 2 channels, and to connect with load cell or pressure transducer of 120Ω-1kΩ.
Parameters can be changed through IRD master module over host industrial network or the dedicated Windows software (IRD Manager).
- IRDS-SA10 : one channel type
- IRDS-SA20 : two channels type
- The data is transferred to the industrial network through IRD master module. (CC-Link, EtherNet/IP, PROFIBUS)
- Possible to have analogue or digital output from other slave modules in IRD system. (IRDS-AIO, AO4 and DO)
- Giving bridge voltage 2V or 5V to load cell and converting voltage output from the load cell to digital data.
- Possible to preset through IRD master module or host industrial network.
- With scaling full voltage range (no matter which bridge voltage) with 16bit, it is not necessary to make calculation for each unit even the bridge voltages are different.
- In case of using 6-wires load cell with long cable, compensating the bridge voltage o load cell and keep it stable by feedback the given bridge voltage.
- Thanks to ratiometric measurement based on GND, no influence from temp. variation and time variation.
- Possible to set upper and lower limit output.
- Self diagnosis function : internal IC error, cable error
- RoHS compliant
Model
IRDS (1) – SA (2) (3) – (4)
(1) series
IRDS : IRD slave module
(2) module function
SA : Strain gauge conditioner module
(3) Number of sensors
| 10 | : one channel |
| 20 | : two channels |
(4) special specification code
| blank | : standard |
| others | : customer’s special option |
Occupied memory block and input / output bytes
Specifications
| Items | IRDS-SA10 | IRDS-SA20 | |
|---|---|---|---|
| Sensor detection | number of sensor | one channel | two channels |
| connectable transducer | 4-wire or 6-wire strain gauge transducer Load-cells or pressure transducer | ||
| bridge voltage | DC 2V or 5V (can be changed by user) Max. 60mA for each axis | ||
| max. analogue input | ±18mV (up to ±3.5mV/V transducer in 5V bridge voltage) (up to ±8.75mV/V transducer in 2V bridge voltage) | ||
| resolution | 0.6μV (16bit for full scale) | ||
| update cycle | 0.2ms | ||
| zero drift | ≤0.1μV/°CRTI | ||
| gain drift | ≤±10ppm/°C | ||
| non-linearity | ≤0.01%FS | ||
| low pass filter | 10Hz / 25Hz / 50Hz / 100Hz / 500Hz / 1kHz / None (1 degree IIR low-pass) | ||
| preset range | Within any range (digital preset) | ||
| Isolation | specification | The inside circuit is isolated from power supply. Withstand voltage 500VAC for one minute. | |
| Power supply | rating | DC24V (±10%) 100mA supplied by IRDM (master module) | |