Meidensha All Functionally Integrated Control And Protection System for Hydroelectric Power Station

Manufacturer: Meidensha Corporation

Features

 

This is an ultra-compact type control & protection system which offers high functions and low cost. It contributes the cost reduction for small & medium capacity hydroelectric power stations.
High reliability and safety
Space-saving
Labor saving in maintenance & inspection
We offer a rich variety of system offerings.

Specifications

Model Code
The MYGENEQUE series, an all-in-one integrated control and protection device, allows you to configure the system by selecting the required functions. Configuration examples are shown in the table below.

ModelSequence Control
(S)
Excitation Control
(E)
Governor Control
(G)
Generator Protection
(R)
Communication Functions
Ethernet Function
(L)
Web Function
(W)
Telecom Function
(T)
MYGENEQUE-SEGRLWT
MYGENEQUE-SEGRLT
MYGENEQUE-SEGR
MYGENEQUE-SEGL
MYGENEQUE-SGR
MYGENEQUE-SEG
MYGENEQUE-SET
MYGENEQUE-SR
MYGENEQUE-EG
MYGENEQUE-T

(Note) Various combinations other than these are also available.
General Specifications
This product is available in two types: General-purpose specification type and Electric power specification type.
For the general-purpose specification type, the applicable standard is basically based on Rationalization Level “a” of the Electric Power Cooperative Research Vol. 57, No. 5, “Rationalization of Control and Protection Systems for General Hydroelectric Power Plants.” However, the protection elements comply with the Electric Power Standard B402. The electric power specification type satisfies the conventional Denkyoken (Electric Power Cooperative Research) standard for hydroelectric power.

ItemSpecifications
Applicable Standards“Modernization of Control and Protection Systems for General Hydroelectric Power Plants” (Electric Cooperative Research Vol. 57 No. 5), Power Utility Standard B402, etc.
Cooling MethodNatural cooling
Power SupplyRated VoltageExternal input power supply: 110V DC      PLC power supply: ① 110V DC (Power utility specs) ② 24V DC (General-purpose specs)
Allowable Voltage RangeExternal input power supply: 90 to 140V DC
Power Consumption33.1W or less
Allowable Instantaneous Power Failure Time20ms
TemperatureAmbient Temperature0 to 40°C (provided that no condensation or freezing occurs)
Storage Temperature-25 to +70°C
Relative Humidity50 to 80% RH
AtmosphereMust be free of explosive, flammable, corrosive gases, and dust
Dielectric StrengthPower utility specs: All power terminals vs FG, 2000V AC for 1 minute (excluding surge removal circuits)
General-purpose specs: All power terminals vs FG, 1500V AC for 1 minute (excluding surge removal circuits)
Noise ResistanceDamped oscillatory wave surge, square wave impulse noise, radio frequency noise, electrostatic discharge noise
Hardware ConfigurationPower utility specs: Single configuration, [Option]: Redundant power supply configuration, Redundant system configuration
General-purpose specs: Single configuration

System configurationMEIDEN

Very compact design system equipped with the necessary functions for hydroelectric power station
Reduction of control cables with the remote I/O function
The subunit equipped with I/O function can be remotely operated from a maximum of 500 m of the length of the optical fiber between the optical FA buses.
The control signal cables can be reduced with optical connection by installing a remote I/O panel equipped with the subunit on the floor of the hydraulic turbine and generator in the power station with a vertical shaft machine.MEIDEN

 