Fluke 4180/ 4181 Precision Infrared Calibrators

Manufacturer: Fluke Calibration
Model: 4180/ 4181

Features

  • Calibrated radiometrically for meaningful, consistent results.
  • Accredited calibration included
  • Accurate, reliable performance from –15 °C to 500 °C
  • Large target size of 152 mm (6 in) is required for calibrating most thermometers.
  • Light instrument weight of 8.6 kg (19 lbs) makes it easy to lift and carry.
  • Intuitive, easy-to-read display that indicates when temperature is stable.

4180/ 4181

Specifications

Specification41804181
Temperature range (@ 23 °C ambient, 0.95 emissivity)–15 °C to 120 °C35 °C to 500 °C
Display accuracy1± 0.40 °C at –15 °C
± 0.40 °C at 0 °C
± 0.50 °C at 50 °C
± 0.50 °C at 100 °C
± 0.55 °C at 120 °C
± 0.35 °C at 35 °C
± 0.50 °C at 100 °C
± 0.70 °C at 200 °C
± 1.20 °C at 350 °C
± 1.60 °C at 500 °C
Stability± 0.10 °C at –15 °C
± 0.05 °C at 0 °C
± 0.10 °C at 120 °C
± 0.05 °C at 35 °C
± 0.20 °C at 200 °C
± 0.40 °C at 500 °C
Uniformity (5.0 in dia of center of target)2± 0.15 °C at –15 °C
± 0.10 °C at 0 °C
± 0.25 °C at 120 °C
± 0.10 °C at 35 °C
± 0.50 °C at 200 °C
± 1.00 °C at 500 °C
Uniformity (2.0 in dia of center of target)2± 0.10 °C at –15 °C
± 0.10 °C at 0 °C
± 0.20 °C at 120 °C
± 0.10 °C at 35 °C
± 0.25 °C at 200 °C
± 0.50 °C at 500 °C
Heating time15 min: –15 °C to 120 °C
14 min: 23 °C to 120 °C
45 min: 35 °C to 500 °C
Cooling time15 min: 120 °C to 23 °C
20 min: 23 °C to –15 °C
100 min: 500 °C to 35 °C
40 min: 500 °C to 100 °C
Stabilization time10 minutes
Nominal emissivity30.95
Thermometer emissivity compensation0.9 to 1.0
Target diameter152.4 mm (6 in)
Computer interfaceRS-232
Power115 V ac (± 10%), 6.3 A, 50/60 Hz, 630 W
230 V ac (± 10%), 3.15 A, 50/60 Hz, 630 W
115 V ac (± 10%), 10 A, 50/60 Hz, 1000 W
230 V ac (± 10%), 5 A, 50/60 Hz, 1000 W
Fuse(s)115 V ac 6.3 A, 250 V, slow blow
230 V ac 3.15 A, 250 V, T
115 V ac 10 A, 250 V, fast blow
230 V ac 5 A, 250 V, F
Size (HxWxD)356 mm x 241 mm x 216 mm (14 in x 9.5 in x 8.5 in)356 mm x 241 mm x 216 mm (14 in x 9.5 in x 8.5 in)
Weight9.1 kg (20 lb)9.5 kg (21 lb)

Notes:
1. For 8 µm to 14 µm spectral band thermometers with emissivity set between 0.9 and 1.0.
2. The uniformity specification refers to how IR thermometers with different spot sizes both focused at the center of the target will measure the same temperature.
3. The target has a nominal emissivity of 0.95, however it is radiometrically calibrated to minimize emissivity related uncertainties.

 