Meidensha AC-DC Converter Equipment for Energy Storage Power And Energy

Manufacturer: MeiMeidensha Corporation
Model: AC-DC

Features

Device map for power storage system products*
PCS for redox flow (RF)
PCS for lithium ion battery (LiB)
Lead storage battery PCS
PCS for lithium ion capacitor (LiC)
Broad lineups with various system capacities from from 250 kVA to 4800kVA
We will build the optimal systems in combination with various storage batteries in consideration of customer’s requirements and characteristics of storage battery.
Our customers benefit from our support in enhancing business continuity, which includes emergency power supply applications and dynamic voltage compensation.
We provide functions in support of various applications including power peak-shaving and grid stabilization.
With No. 1 supply records in Japan, we provide high quality products and standardized design.AC-AD

Types of storage battery for energy storage

AC-ADThere are various storage batteries for energy storage, and each battery has distinct features.
Meiden proposes the optimal combination of right storage battery and AC-DC converter equipment to fit the purpose and application of the customer by drawing on our rich supply experiences.
NAS battery (Note: NAS battery is a registered trademark or product name of NGK Insulators, Ltd.  and Tokyo Electric Power Company, Incorporated.)
Load leveling/ peak shaving, grid independent operation function, instantaneous voltage drop countermeasure (UPS) function, system stabilization (adjustment of frequency), etc.

Redox flow (RF) battery
Load leveling/ peak shaving, grid independent operation function, grid stabilization, etc.
Lithium ion (LiB) battery
Grid stabilization, load fluctuation suppression (mitigation of electric power fluctuation), etc.
Lead storage battery
Stand-alone operation function, instantaneous voltage drop countermeasure (UPS) function, etc.
Lithium ion capacitor
Dynamic voltage compensation (DVC) by UPS, grid stabilization, load fluctuation suppression, utilization of regenerative power, etc.AC-AD

Applications

Load leveling/ peak shaving:
The energy storage system stores cheap night-time power and discharges it during the day for peak-shaving. This strategy allows you to reduce contract power demand and shave peaks during the daytime power peak period.
Stand-alone operation function:
The energy storage battery supplies power to the load. Compared to diesel or gas turbine emergency generators, this function ensures a rapid startup (under 2 seconds) and discharges no soot or smoke.
Dynamic voltage compensation (DVC) function by UPS:
It protects the load facilities on the power network against instantaneous voltage drops (power outages). Because the system equips the energy storage battery with a large capacity, it provides a longer power interruption backup than a normal UPS (5 to 30 minutes).
Grid stabilization:
The system charges and discharges the storage battery to mitigate grid voltage and frequency fluctuations. It can supply both reactive and active power.
Load fluctuation suppression:
The system charges and discharges the storage battery to mitigate sudden fluctuations in the local load. It can supply both reactive and active power. Furthermore, combining the system with a private power generator reduces the load’s starting current, thereby expanding the generator’s autonomous operation capacity.
Utilization of regenerative power:
The system prevents reverse power flow by absorbing (charging) the regenerative power that occurs when the electric motor decelerates. In addition, the system discharges this absorbed electric power when the electric motor accelerates, which saves energy.

Specifications

Equipment namePower conditioning subsystem (PCS) for NAS battery system
(Large capacity system)
Power conditioning subsystem (PCS) for storage battery
(Medium/ small capacity system)
Equipment capacity600kW/1200kW/1800kW
/2400kW/3600kW/4800kW
250kW/500kW/750kW/
1000kW/1250kW/1500kW/
1750kW/2000kW
Grid voltage (AC side)6.6kV(3.3kV)440V/420V/400V
Battery voltage fluctuation range (DC side)480~750V240V~600V
Applicable storage battery
FunctionsNAS battery×
Redox flow battery
Lithium ion battery
Lead storage battery
Lithium ion capacitor
Load balancing/ power peak-shaving
Autonomous operation
Dynamic voltage compensation (DVC) by UPS×
Grid stabilization
Load fluctuation suppression
Utilization of regenerative energy

REQUEST QUOTATION

PAYMENT

payment-methods

LINK

koueigroup-banner1
koueigroup-banner1

Return Top