NOHMI BOSAI
NOHMI BOSAI FDLU019-D-X Fixed Temperature Heat Detector
Made in Japan
Manufacturer: NOHMI BOSAI
Model: FDLU019-D-X
Features of FDLU019-D-X
- Low-profile design, only 30.7mm (1.21-inch) in height.
- Equipped with a heat sensor that operates between 57°C to 85°C (135°F to 185°F).
- True analog detector for reliable fire detection.
- Operates within ambient temperatures of 0°C to 66°C (32°F to 150°F).
- Easy address setting, no need for mechanical switches.
- LED indicators provide 360° viewing for enhanced visibility.
Description of FDLU019-D-X
- The Fixed Temperature Heat Detector (FDLU019-D-X) is designed to work seamlessly with any fire alarm control panel from the IntegleX Multicrest series. Its heat sensor uses a proven thermistor for accurate and dependable heat detection. The detector and its base (not included) are built from durable plastic in an off-white color, which blends effortlessly with the ceiling.Nohmi has introduced advanced circuit integration technology into the FDLU019-D-X. This innovation simplifies the detector’s internal circuitry and significantly reduces the product’s size, making installation more efficient.With a selectable fixed temperature range of 57°C to 85°C (135°F to 185°F), the FDLU019-D-X meets UL standards. This broad range allows flexibility for different installation needs, accommodating various applications with a single unit.
The detector features two LEDs that provide 360° visibility, ensuring you can view status indicators from any angle. It is compatible with Nohmi’s wide range of bases and installs effortlessly by twisting it onto the base. Addressing the FDLU019-D-X is simple and can be done using a handheld programmer or through the control panel’s addressing function.
Specifications
No. | Item | Specification |
---|---|---|
1 | Working voltage range | 22.0 to 24.0 V |
2 | Standby current | 250 µA |
3 | Alarm indicator | 2 LEDs |
4 | Alarm indicator current | 1.5 mA D.C |
5 | Alarm set-point range | 57°C to 79°C (135°F to 174°F) 80°C to 85°C (175°F to 185°F) |
6 | Installation temperature range | 0°C to 38°C (32°F to 100°F) 0°C to 66°C (32°F to 150°F) |
7 | Operating relative humidity range | 0% to 93% (Non-condensing) |
8 | Start-up time | Max. 1 sec. |
9 | Color | Eggshell White |
10 | Weight (without base) | 65g (2.29 oz) |
11 | Dimensions (without base) | Height: 30.7mm (1.21 inch) Diameter: 99mm (4.0 inches) |
Setting the Address
Each addressable module, smoke detector, heat detector, and combination detector must have the address set before connecting the device to the Signaling Line Circuit (SLC) loop. The address is set using the hand-held programmer.
Compatible Bases
No. | Device | Description |
---|---|---|
1 | FZBU004-AB4 | 4 inches Standard Base |
2 | FZBU003-AB6 | 6 inches Standard Base |
3 | FZBU013-2Z | 4 inches Standard base, 2 terminals (without remote indication circuit) |
4 | FZBU013-4Z | 4 inches Standard Base, 4 terminals |
5 | FZBU005-AIB | 6 inches base that has an isolator module included. The base is pre-wired with a pluggable jumper to the module. |
6 | FZBU005-ARB | 6 inches base that includes a dual relay module. One relay is rated for 8 amps at 240 VAC/30 VDC and the second is rated for 2 amps at 240 VAC/30 VDC. The base is pre-wired with a pluggable jumper to the module. |
7 | FZBU005-ASB | 6 inches base with sounder module included. Sound pattern is provided from external source. The base is pre-wired with a pluggable jumper into the module. |
Wiring Diagram
Related Products
-
NOHMI BOSAI NEC3-24WR Strobe Horn
-
NOHMI BOSAI FDKU026-D-X Photoelectric Smoke Detector
-
NOHMI BOSAI FRRJ001A-Y-SS/FRRJ001-Y-2SS/FRRJ001-Y-4SD Addressable Module, Dry Contact Type
-
NOHMI BOSAI FAPN202-R-5L Fire Alarm Panel
-
NOHMI BOSAI FRRU004-MOM4 Monitored Output Module
-
NOHMI BOSAI PCA-N3060-SCU Sub Control Unit