Japan, Measuring Instrument
OSC57FY108 Thermo-Hygrometer With Infra Red Thermometer

Model: OSC57FY108
Applications
– Food preparation
– Safety and fire inspectors
– Plastic molding
– Asphalt
– Marine and screen printing
– Measure ink and dryer temperature
– Diesel and fleet maintenance
Features
– Two in one precise non-contact measures temperature (deg.C/deg.CF) and relative humidity simultaneously
– Dual LCD display for temperature and humidity
– Built in laser pointer to improve non-contact infrared thermometer aim
– Resolution to 0.1%RH, 0.1deg.Cor 1deg.C(deg.C/deg.CF)
– Switchable deg.C/deg.CFunits with MAX and HOLD functions
– Auto power off
– The meter at 8 inches away measure 1-inch target
– Backlit LCD display
– Ideal for clean rooms, drying rooms, greenhouses, food and textile industries
Specifications
| Model | OSC 57FY 108 | ||
| Display | Dual LCD display for temperature and humidity with backlight | ||
| Ir Meas. Ranges | -50.0deg.C to 500deg.C/ -58.0deg.CF to 932deg.CF | ||
| Humidity Ranges | 0% to 100%RH | ||
| Sample Rate | 2.5 times/ second | ||
| Over Range Indication | LCD will show “OL” | ||
| Polarity | Automatic (no indication for positive polarity): Minus(-) sign for negative polarity | ||
| Ir Spectral Response | 6 to 14micrometer | ||
| Power off | Automatic shut off after 10 minutes, approx | ||
| Operating temp | 0deg.C to 50deg.C (32deg.CF to 122deg.CF) | ||
| Operating %rh | Max 80%RH | ||
| Power supply | 9V battery | ||
| Weight (g) | Approx 200 | ||
| Size (H x W x D mm) | Approx 150 x 75 x 40 | ||
Infrared thermometer specifications
| Range | Resolution | Accuracy | |
| -50.0deg.C to 200.0deg.C | -50.0deg.C to -20.0deg.C | 0.1deg.C | ±5deg.C |
| -20.0deg.C to 200.0deg.C | ±2% of reading or ±2deg.C | ||
| 200.0deg.C to 500.0deg.C | 1deg.C | ±2% of reading or ±2deg.C | |
| Range | Resolution | Accuracy | |
| -58.0deg.CF to 200.0deg.CF | -58.0deg.CF to -4.0deg.CF | 0.1deg.CF | ±9deg.CF |
| -4.0deg.CF to 200.0deg.CF | ±2% of reading or ±4deg.CF | ||
| 200deg.CF to 932deg.CF | 1deg.CF | ±2% of reading or ±4deg.CF | |
Note:
1. Accuracy is given at 18deg.C to 28deg.C (64deg.CF to 82deg.CF), less than 80% RH
2. Accuracy specified is for the emissivity of 0.95
Emissivity settings: 0.95 fixed
Distance factor:
D:S = Approx 8:1 (D = distance, S = spot)
Relative humidity/Air temperature
| Range | Resolution | Accuracy | |
| 5.0%RH to 95.0%RH | 0.1%RH | ±3.5%RH | |
| -20.0deg.C to 60.0deg.C | 0.1deg.C | ±2deg.C | |
| -4.0deg.CF to 140.0deg.CF | 0.1deg.CF | ±3deg.CF | |
Related Products
-

SAKUSAKU CCGT09T308-UG Turning Insert 80° Rhombic/7° Positive
-

Hammer Caster 960BPS Trivalent Chromate Conversion Coated Caster
-

Ross Asia ISO 15407-1(W66 series) ISO valve series
-

Chino IR-TE2 Water-proof Palm-sized Radiation Thermometers
-

TONE TMC402T Lightweight Hydraulic Force Gauge
-

TONE BGBB2, BGBB2YL, BGBB2GR Bolt Bag