Japan, Measuring Instrument
OSC57FY108 Thermo-Hygrometer With Infra Red Thermometer
Model: OSC57FY108
Applications
– Food preparation
– Safety and fire inspectors
– Plastic molding
– Asphalt
– Marine and screen printing
– Measure ink and dryer temperature
– Diesel and fleet maintenance
Features
– Two in one precise non-contact measures temperature (deg.C/deg.CF) and relative humidity simultaneously
– Dual LCD display for temperature and humidity
– Built in laser pointer to improve non-contact infrared thermometer aim
– Resolution to 0.1%RH, 0.1deg.Cor 1deg.C(deg.C/deg.CF)
– Switchable deg.C/deg.CFunits with MAX and HOLD functions
– Auto power off
– The meter at 8 inches away measure 1-inch target
– Backlit LCD display
– Ideal for clean rooms, drying rooms, greenhouses, food and textile industries
Specifications
Model | OSC 57FY 108 | ||
Display | Dual LCD display for temperature and humidity with backlight | ||
Ir Meas. Ranges | -50.0deg.C to 500deg.C/ -58.0deg.CF to 932deg.CF | ||
Humidity Ranges | 0% to 100%RH | ||
Sample Rate | 2.5 times/ second | ||
Over Range Indication | LCD will show “OL” | ||
Polarity | Automatic (no indication for positive polarity): Minus(-) sign for negative polarity | ||
Ir Spectral Response | 6 to 14micrometer | ||
Power off | Automatic shut off after 10 minutes, approx | ||
Operating temp | 0deg.C to 50deg.C (32deg.CF to 122deg.CF) | ||
Operating %rh | Max 80%RH | ||
Power supply | 9V battery | ||
Weight (g) | Approx 200 | ||
Size (H x W x D mm) | Approx 150 x 75 x 40 |
Infrared thermometer specifications
Range | Resolution | Accuracy | |
-50.0deg.C to 200.0deg.C | -50.0deg.C to -20.0deg.C | 0.1deg.C | ±5deg.C |
-20.0deg.C to 200.0deg.C | ±2% of reading or ±2deg.C | ||
200.0deg.C to 500.0deg.C | 1deg.C | ±2% of reading or ±2deg.C | |
Range | Resolution | Accuracy | |
-58.0deg.CF to 200.0deg.CF | -58.0deg.CF to -4.0deg.CF | 0.1deg.CF | ±9deg.CF |
-4.0deg.CF to 200.0deg.CF | ±2% of reading or ±4deg.CF | ||
200deg.CF to 932deg.CF | 1deg.CF | ±2% of reading or ±4deg.CF |
Note:
1. Accuracy is given at 18deg.C to 28deg.C (64deg.CF to 82deg.CF), less than 80% RH
2. Accuracy specified is for the emissivity of 0.95
Emissivity settings: 0.95 fixed
Distance factor:
D:S = Approx 8:1 (D = distance, S = spot)
Relative humidity/Air temperature
Range | Resolution | Accuracy | |
5.0%RH to 95.0%RH | 0.1%RH | ±3.5%RH | |
-20.0deg.C to 60.0deg.C | 0.1deg.C | ±2deg.C | |
-4.0deg.CF to 140.0deg.CF | 0.1deg.CF | ±3deg.CF |
Related Products
-
Matsumoto Kikai MA-305~405/MKM-405/MTR-405 Super Saw for Ironworking
-
SAKUSAKU 4SS-30D 1.5S Carbide Square End Mill 4-Flute
-
OSC77FD530HF Tilting Flow Channel (300mm Wide)
-
NAGANO KEIKI KL76 General industry application
-
ASCO Explosion-Proof Switch Box
-
Shinano SI-3003B/SI-3003BM Velcro pad model Orbital Sander