NOHMI BOSAI FPI012B-1L Series Dedicate Control Panel

Manufacturer: NOHMI BOSAI
Model: FPI012B-1L Series

Description of FPI012B-1L Series

Nohmi’s infrared three-wavelength flame detector quickly detects fire even in places with ventilation flow, external air, or high ceilings where detection is often difficult for the ordinary detectors.
This high-sensitivity detector is suitable not only for large spaces but also for outdoor facilities.

Specification

TypeDedicated control panel
For AC power supplyFor DC power supply
ModelFPJ012B-1L–5L-AFPJ012B-1L–5L-D
Number of circuits1 2 3 4 51 2 3 4 5
Mounting typeWall mounting type
Main power supplyAC100V±10%, 50/60HzDC24V±10%
Circuit voltage[Power for the detector, signal-receiving circuit, and display circuit] 24V DC (constant voltage)
[IC circuit] 3.3 VDC (constant voltage)
[Power for the detector, signal-receiving circuit, and display circuit] 24V DC (constant voltage)
[IC circuit] 3.3 VDC (constant voltage)
Power consumptionMonitoring (VA): 6 11 16 21 26
Alarm in 2 circuits (VA): 11 16 21 26 31
Monitoring (VA): 8 12 16 20 24
Alarm in 2 circuits (VA): 12 16 20 24 28
Maximum number of devicesPDCJ001-D, PDCJ002-E Infrared Three-Wavelength Flame Detector: 1unit/circuit
Panel soundBuilt-in electronic buzzer (Alarm: Constant, Trouble: Intermittent)
Test & maintenance functionDetector operation test: Manual operation test of the detector (by the test switch)
Reset: Reset of detectors and signal-receiving circuits (by the reset switch)
Signal cut-off: Cut-off of alarm and trouble output signals (by the signal cut-off switch)
Alarm silence: Silence of the control panel (by the alarm silence switch)
Trouble notice functionAutomatic open-circuit notice function: Monitors the detector status and the open circuit between the control panel and the detector (The alarm LED blinks when the circuit is open and there is a detector problem)
Signal outputAlarm (latch): All points, 30 VDC, 1 A or less
Trouble: 1 point (all points available as an option), 30 VDC, 1 A or less
Alarm detectionVerification: After 2 seconds of detector operation, reset the detector / signal-receiving circuit of the control panel. If during these 13 seconds the control panel experiences no fire, the alarm is judged as fire.
Non-verification: The control panel judges it as fire as soon as the alarm signal is received.
Environmental conditionOperating temperature: 0~40°C
Operating humidity: 20~85% (RH), No condensation
Maximum cable lengthPDCJ001-E:
330 m (when the cable size is φ0.9), 590 m (when the cable size is φ1.2)
PDCJ002-E:
560 m (when the cable size is φ0.9), 990 m (when the cable size is φ1.2)
End-of-line resistor10 kΩ, 1/2 W (Connected to the terminal in the detector)
Main materialSteel plate t1.2
FinishMelamine baking finishing
DimensionsH400×W350×D170 (mm)
WeightMax. 15 kgMax. 14 kg