DEICY
Deicy CAC Series In-Line Charge Converter



Manufacturer: DEICY Co., Ltd.
Model: CAC Series
Features
- The in-line charge converter is a charge signal to voltage signal converter for using a charge type acceleration sensor with an IEPE amplifier, and can be used by inserting it between the sensor cable and the input connector of the amplifier unit.
Specifications
Model | CAC1R0 | CAC100 | CAC500 | CAC101 |
---|---|---|---|---|
Gain (mV/pC) | 1.0 ± 2.5% | 10 ± 5% | 50 ± 5% | 100 ± 5% |
Frequency Range (Hz ± 3dB) | 2 ~ 50,000 | 2 ~ 50,000 | 2 ~ 100,000 | 2 ~ 50,000 |
Output Impedance (Ω or less) | 200 | 500 | 100 | 100 |
Maximum Output Voltage (Vp-p or more) | 10 | 10 | 8.5 | 8.5 |
DC Output Voltage (V) | 10 ± 2 | 10 ± 2 | 12 ± 2 | 12 ± 2 |
Driving Voltage (VDC) | 18 ~ 36 | 18 ~ 36 | 18 ~ 27 | 18 ~ 27 |
Driving Current (mA) | 2.0 ~ 20 | 2.0 ~ 20 | 2.0 ~ 20 | 2.0 ~ 20 |
Noise Level (pC rms or less) | 0.05 | 0.05 | 0.15 | 0.15 |
Operating Temperature Range (°C) | 0 ~ +50 | 0 ~ +50 | 0 ~ +50 | 0 ~ +50 |
Input Connector | Miniature (10-32) | Miniature (10-32) | Miniature (10-32) | Miniature (10-32) |
Output Connector | BNC | BNC | BNC | BNC |
Dimensions (mm) | φ15 × L35.5 | φ15 × L35.5 | φ15 × L48.5 | φ15 × L48.5 |
Weight (g) | 20 | 20 | 25 | 25 |
Related Products
-
Deicy KS80D / KS81B One Axis Industrial Insulation Type
-
Deicy CU-DC16 16ch DC Voltage Input Unit
-
Deicy MHL1400 Series Contactless Rotary Position Sensor
-
Deicy VLP1500 Series High Performance Linear Potentiometer
-
Deicy MHR0500 Series Magnetic-Hall Rotary Position Sensor (Miniature)
-
Deicy ADMA-G-PRO+ High-Precision Inertial Sensor For Vehicle Behavior Measurement