Japan, Pollution and Environment
OSC92GT200, 200A Freon Gas Detector
Model: OSC92GT200, 200A
Features
- Newly developed multi layer sensor reduces other gas
– 2 layers fetches other gas and passes freon
– Reduces reaction to adhesive agent and Styrofoam which are used for alcoholic solvent and PCB board
- Excellent stability in detecting R134a and R600a
– Corresponds to various alternative refrigerant and conventional refrigerant which are commonly used for domestic refrigerator and vending machines
– Suitable for leak detect inspection at factories
- Environmental monitor incorporated as standard to check back ground status
– Possible to grasp status of laboratory environment and auto balance securely
– Environmental pollution level is displayed on LED screen in 10 steps colors
- Easy maintenance, less consumables enabling low running cost
– Durable semiconductor sensor and replacement is easy
– Basic consumables are cartridge filter only
Only for OSC 92GT200A
- NIST authorized calibration device is equipped as standard
– Detector calibration can be done quickly and easily
– Calibration gas can be used for more than 10 year without replacement
Specifications
MODEL | OSC 92GT100 | |
Objective gas | Existing general fleon gases such as R12, R22, R502, R134a, R404A, R407C, R410A, R600a | |
Detecting method | Semiconductor sensor suction method | |
Maximum sensitivity | 5X10-6ml/sec (approx. 0.5g/year) in case of R134a | |
Reaction speed | within 1.5 sec (at range H5, suction volume 250 mL/min) | |
Sensitivity range selection | H/L ranges 5 steps each | |
Suction method | Auto suction pump (max. 300 mL/min) | |
Leak indication | Analog meter and buzzer (buzzer volume and alarm point adjustable) | |
Calibration device (only OSC 92GT200A) | Incorporated NIST authorized calibration device R134a 1.1~2.9 g/year | |
Power source | AC100V-240V (50/60Hz) | |
External output | Voltage output for recorder DC0-5V, Alarm contact output (A point AC125V 1A) | |
Operational environment | 20±15℃ 65±20%RH | |
Dimensions and weight | 350W x 270D x 160H mm, approx. 8.7 kg | |
Standard accessories | Standard probe (2 m) x 1, Spare fuse (3A) x 1, Cartridge filter x 5, perfornace data sheet, operation manual, certificate of guarantee 2 | |
Optional extra | Sensor, Probe Ass’y, Probe tube, Probe tip carbon flex, Cartridge filter, O-ring for cartridge filter, Fuse for FER | |