KETT ELECTRIC LABORATORY FD-720 Infrared Moisture Analyzer

Product Made in Japan
Manufacturer: KETT ELECTRIC LABORATORY
Model: FD-720

Features of FD-720

FD-720

Mid-class model of infrared moisture analyzer

Minimum moisture content display 0.01%, weight display 1mg

Features infrared quartz heater that achieves high drying-efficiency

Six types of measurement modes

Specification

Measurement MethodHeat drying and weight loss
Sample mass0.5~120g
Measurement subjectMoisture / Solid content / Weight
Reproducibility (Standard deviation)Sample with a weight of 5g or higher: 0.05% Sample with a weight of 10g or higher: 0.02%
Measurement range0~100% (wet base, solids),0~500%(dry base)
Resolution0.01% , 1mg
Temperature range30~180°C
Measurement modesAutomatic operation mode: Timed operation mode (1~240min or continuous): High-speed drying mode: Low-speed drying mode: Stepped drying mode (max of 5 steps): Predictive measuring mode
External outputRS-232C interface
Environmental conditionsTemperature 5~40°C, Humidity: max of 85%RH Pollution degree 2, Altitude up to 2000m
Sample dishSUS (diameter 130mm, depth 13mm )
Heat sourceMid-wave infrared quartz heater (200Wx2)
Power supplyAC100~120V / 220~240V (50/60Hz)
Power consumptionmax 900W
Size and Weight220(W)x415(D)x190(H), 4.5kg ,Shipment 310(W)x580(D)x400(H), 10kg
AccessoriesSample dish 2 pcs, Sample dish handler 2 pcs, Windshield, Sample dish tray, Spoon and spatula set, Spare fuses(T8A 250V) 2 pcs, Power cord, Aluminum sheets(20 pcs)x2, Operating manual
OptionsPrinter set( Printer VZ-330), Datalogger software “FDL-02”, Radiation thermometer calibration kit GF-100

Options

VZ-330

Example of VZ-330 output: 

FW-100

FW-100 can be installed within t h e F D -720 to reduce errors caused by the influence of external airflow on the high precision balance. Further, since a deodorizing filter is provided on its upper portion, it is also possible to reduce odors created during heat drying.

FDL-02: Data logger software

By connecting the FD-720 to a PC in which the “Datalogger software FDL-01” and MS Excel® are installed, it is possible to transfer and save the measurement data to the PC in real-time. Also, it is possible to display the recorded measurement data graphically, so that the moisture and temperature condition changes can be visually confirmed. The graph can show the moisture, thermistor (T1) temperature, and radiation thermometer (T2) temperature.

Different forms of samples can be measured

Most samples that vaporize only moisture and cause no hazardous reaction under heating can be measured.


Other items of KETT ELECTRIC LABORATORY

Request the quotation for KETT ELECTRIC LABORATORY

REQUEST QUOTATION

PAYMENT

payment-methods

Return Top