KOKEN LTD.
Koken 1005 Series Dust Mask

Manufacturer: KOKEN LTD.
Model: 1005 Series
Important points when wearing a mask
Dust masks utilize high-efficiency filters to effectively prevent the inhalation of hazardous particles. To protect yourself from inhaling dust while wearing a dust mask, both the performance of the filter and the “tight seal” (fit) between the mask and your face are critical.
1. Filter Technology with High Particle Collection Efficiency
Mighty (Uni) Micron Filter
Using unique technology, wool fibers are electrostatically charged, allowing electrostatic force to draw particles to the fiber surface. This is the primary mechanism for capturing particles. A high-density fiber structure is unnecessary, successfully integrating the two contrasting features: “high collection efficiency” and “low inhalation resistance.” It consistently maintains the highest standard of performance and quality, making it an excellent long-term filter solution.
![]() | ![]() |
Applied products are on P.4 ~ 6, P.11
Alpha Ring Filter
Increasing the fiber density of the filter enhances collection efficiency. To meet airflow resistance standards, paper filters traditionally require an expanded surface area.
For the first time in Japan, ultra-fine fibers were formed into pristine circular shapes in a single process, creating the Alpha Ring filter. Today, this filter continues to succeed in expanding the surface area while maintaining a compact shape, significantly reducing airflow resistance.
![]() | ![]() |
Applied products are from page P.8 to P.11
Dust Respirator Standards
In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured.
| Dust Respirator Standards | In addition to JIS standards, dust respirators are tested according to assay standards based on national regulations. These standards are comprehensive, ensuring that products meeting strict safety requirements are manufactured. |
|---|
Note: The table below is excerpted from the “Dust Respirator Standards”.
| Replaceable Dust Respirator | Isolation Type Dust Respirator |
|---|---|
| Direct-Connection Type Dust Respirator | |
| Disposable Dust Respirator | |
| Test Particles | Type | NaCl (Sodium Chloride) | DOP (Dioctyl Phthalate) | ||
|---|---|---|---|---|---|
| Particle Size | 0.06 μm to 0.1 μm | 0.15 μm to 0.25 μm | |||
| Concentration | 50mg/m³ or less | 100mg/m³ or less | |||
| Test Flow Rate | 85 ℓ /min | 85 ℓ /min | |||
| Particle Collection Efficiency (Continuous measurement; must meet values in the right column) | For NaCl test aerosol Load up to 100mg | For DOP test aerosol Load up to 200mg | |||
| Replaceable Type | RS1 | 80.0% or higher | RL1 | 80.0% or higher | |
| RS2 | 95.0% or higher | RL2 | 95.0% or higher | ||
| RS3 | 99.9% or higher | RL3 | 99.9% or higher | ||
| Disposable Type | DS1 | 80.0% or higher | DL1 | 80.0% or higher | |
| DS2 | 95.0% or higher | DL2 | 95.0% or higher | ||
| DS3 | 99.9% or higher | DL3 | 99.9% or higher | ||
| Inhalation Resistance (Test flow rate 40 ℓ /min) | Replaceable Type | Disposable Type | |||
| RS1 RL1 | 70Pa or less | DS1 DL1 | 60Pa or less (45Pa or less) | ||
| RS2 RL2 | 80Pa or less | DS2 DL2 | 70Pa or less (50Pa or less) | ||
| RS3 RL3 | 160Pa or less | DS3 DL3 | 150Pa or less (100Pa or less) | ||
| Exhalation Resistance (Test flow rate 40 ℓ /min) | Replaceable Type | Disposable Type | |||
| RS1 RL1 | 70Pa or less | DS1 DL1 | 60Pa or less (45Pa or less) | ||
| RS2 RL2 | 70Pa or less | DS2 DL2 | 70Pa or less (50Pa or less) | ||
| RS3 RL3 | 80Pa or less | DS3 DL3 | 80Pa or less (100Pa or less) | ||
( ) indicates products without an exhalation valve.
| Exhalation Valve Airtightness | Exhalation valve operation leak test | – When air is drawn, the internal pressure must decrease immediately – The time for internal pressure to return to normal atmospheric pressure must be 15 seconds or more |
|---|---|---|
| Carbon Dioxide (CO2) Concentration Increase | Using a test headform and an artificial lung to inhale/exhale air containing CO2. The difference in CO2 concentration in the inhaled air between wearing and not wearing the mask must be 1.0% or less. | |
| Dead Space Volume | Value calculated from the (Carbon Dioxide Concentration Increase Test) | |
| Inhalation Resistance Increase | Test Aerosol | NaCl (Sodium Chloride) |
|---|---|---|
| Test Flow Rate | Measured at 40 ℓ/min after loading test dust at 85 ℓ/min | |
| Amount loaded onto dust respirator | 100mg |
Test aerosol and collection efficiency Disposable Type | S | L | Classification (Collection efficiency) | |
|---|---|---|---|---|
| Test aerosol is Solid Sodium Chloride (NaCl) | Test aerosol is Liquid Dioctyl Phthalate (DOP) | |||
| R | Replaceable Dust Respirator | RS1 | RL1 | Class 1 (Above 80.0%) |
| RS2 | RL2 | Class 2 (Above 95.0%) | ||
| RS3 | RL3 | Class 3 (Above 99.9%) | ||
| D | Disposable Dust Respirator | DS1 | DL1 | Class 1 (Above 80.0%) |
| DS2 | DL2 | Class 2 (Above 95.0%) | ||
| DS3 | DL3 | Class 3 (Above 99.9%) | ||
High Efficiency Filter + Ergonomic Face Seal
2. Facepiece Fit Technology
Even if a dust mask has a high collection efficiency filter, it is ineffective if dust leaks through the facepiece seal during use. The primary cause of exposure is the “gap at the facial contact area.” We consider mask fit to be just as important as filter performance. Therefore, our company developed technology to enhance the airtightness of the facial contact area early on.
Silicone Facepiece
Silicone is a hypoallergenic material that is gentle on the skin. Its surface is flexible and effortlessly adapts to facial movements, ensuring a comfortable fit and stability during use.
HAWC harness strap
The strap design ensures a high level of fit, maximizing the “suction” effect when wearing the mask to ensure an airtight seal on the face. 
Freeposition Underchin
The unique curve of the facial contact area prevents dust entry. The nose section is aligned first, allowing it to accommodate various facial dimensions and providing a secure fit for a wide range of face sizes (see image below).

Fit Status of the Freeposition Underchin Facepiece
(Cross-sectional simulation to show the contact position between the mask and the chin).
| For large faces: Uses the outer section of the mask to adjust the fit around the chin. | ![]() | For small faces: Uses the inner section of the mask to adjust the fit around the chin. | ![]() |
| FF Lip | Wearing Stability | Internal Fit Checker | |||
|---|---|---|---|---|---|
![]() | Designed for various face shapes; the cushion naturally fits your face. | ![]() | Utilizes a 3D poly-band harness that matches head shapes to enhance fit and seal. | ![]() | Fit checker is integrated inside, helping to check the mask seal at any time (available for models 1005, 1010A, 1015, 1180 series). |
Replaceable Dust Mask
Mighty Micron Filter
The yellow filter is the hallmark
Mighty Micron Filter
Thanks to proprietary technology, this filter is created by electrostatically charging the base wool fiber material. In addition to a strong electrostatic force, a 3-layer structure with a void space between two collection layers achieves low fiber density while combining two opposing characteristics: high collection efficiency and low inhalation resistance.

- Fit checker: Perform a seal test (fit test) simply by operating a lever.
- Under-chin: Unique curve design enhances the seal at the facial contact area.
- Silicone: Uses soft, skin-friendly silicone for a comfortable wearing experience.
- Size S available: Small face size options are available for these models.
- Micron: Employs high-performance electrostatic filters compliant with RL classifications.
Sakai – Model 1005R-08
Integrated Fit Checker – Suitable for welding operations
Model Assay Certificate: TM540
Assigned Protection Factor: 10
Classification: RL2

- Fit Checker (Integrated seal check lever)
- Under-chin support
- Silicone seal
- Size S available
- Micron Filter
| Collection Efficiency | 95.0% or higher | (Average 99.1%) |
|---|---|---|
| Inhalation Resistance | 75Pa or less | (Average 58Pa) |
| Exhalation Resistance | 52Pa or less | (Average 31Pa) |
| Resistance Increase | ― | (Average 68Pa) |
| Weight | 155g or less | (Average 143g) |
| Harness | RB Type |
Sakai – Model 1005RR-05
Compatible with KBC filter for ozone and organic odor removal
Integrated Fit Checker
Model Assay Certificate: TM541
Assigned Protection Factor: 10
Compatible with KBC filter
Classification: RL2

- Fit Checker
- Under-chin support
- Silicone seal
- Size S available
- Micron Filter
| Collection Efficiency | 95.0% or higher | (Average 99.0%) |
|---|---|---|
| Inhalation Resistance | 73Pa or less | (Average 56Pa) |
| Exhalation Resistance | 52Pa or less | (Average 31Pa) |
| Resistance Increase | ― | (Average 66Pa) |
| Weight | 157g or less | (Average 145g) |
| Harness | RB Type |
Sakai – Model 1005R-AL-02
Suitable for environments with radiant heat
Aluminized coating
Integrated Fit Checker
Model Assay Certificate: TM543
Assigned Protection Factor: 10
Classification: RL2

- Fit Checker
- Under-chin support
- Silicone seal
- Size S available
- Micron Filter
| Collection Efficiency | 95.0% or higher | (Average 98.9%) |
|---|---|---|
| Inhalation Resistance | 75Pa or less | (Average 58Pa) |
| Exhalation Resistance | 52Pa or less | (Average 29Pa) |
| Resistance Increase | ― | (Average 70Pa) |
| Weight | 165g or less | (Average 143g) |
| Harness | RB Type |
Sakai – Model 1005RRX-05
Compatible with KBC filter for ozone and organic odor removal
Integrated Fit Checker
4-point head harness
Model Assay Certificate: TM542
Assigned Protection Factor: 10
Compatible with KBC filter
Classification: RL2

- Fit Checker
- Under-chin support
- Silicone seal
- Size S available
- Micron Filter
| Collection Efficiency | 95.0% or higher | (Average 99.0%) |
|---|---|---|
| Inhalation Resistance | 73Pa or less | (Average 55Pa) |
| Exhalation Resistance | 52Pa or less | (Average 30Pa) |
| Resistance Increase | ― | (Average 66Pa) |
| Weight | 168g or less | (Average 155g) |
| Harness | XRB Type |
▲ Shared Replacement Parts for 1005 Series
- Inhalation Valve (Circular)
- Exhalation Valve (T-6K)
- Moisture Sponge (Egg-shaped)
Replacement Filters · Optional Accessories
![]() | ![]() |
| Mighty Micron Filter for 1005-02 | KBC Filter for 1005 (Ozone & organic odor removal, 5 sets/pack) (Optional) → For 1005RR / 1005RRX |
(Head Harness Types)
Please replace the head straps periodically.

Collection Efficiency with DOP Particles (using 1005R)

Up to a load of 200 mg of DOP particles, the minimum collection efficiency was 98.74%. Even for DOP particles—which tend to degrade electrostatic forces faster than other oil mists—the Mighty Micron filter maintains very high performance.
Collection Efficiency against Welding Fume (30 mg/m³) – using 1005R

During the accumulation of 100 mg of welding fume, the minimum collection efficiency was 99.927%. After this, the mechanical sieving effect becomes dominant, maintaining extremely high efficiency. → Efficiency at 100 mg load: 99.993%.
Built-in Fit Checker – Rapid Seal Verification
Regardless of filter efficiency, a mask provides no protection if not worn correctly. For this reason, national regulations require replaceable dust masks to have an easy method for fit testing.
Our company was the first in Japan to develop an integrated fit checker, allowing for simpler seal checks. There is no need for external testing equipment; users can verify the fit instantly on-site.
This design encourages workers to perform seal checks every time they don the mask, ensuring consistent safety.
Applicable Series:
1005 series, 1010A, 1015, 1180 series

Simply move the lever to close the inhalation port and perform a negative pressure seal check.
Sakai Model 1010A-06
RL1 Rating
Integrated Fit Checker
Lightest in class: 76 g (compared to other replaceable filter models from Koken)
Model Assay Certificate: TM560
Assigned Protection Factor: 4

- Fit Checker
- Mighty Micron Filter
| Collection Efficiency | 80.0% or higher (Average 94.4%) |
|---|---|
| Inhalation Resistance | 70Pa or less (Average 59Pa) |
| Exhalation Resistance | 63Pa or less (Average 38Pa) |
| Resistance Increase | ― (Average 109Pa) |
| Weight | 83g or less (Average 76g) |
| Harness | RB Type |
Replacement Parts
- Inhalation Valve – Oval type (Small)
- Exhalation Valve – T-6K type
- Moisture Sponge – Egg-shaped
Sakai Model 1015-02
RL2 Rating
Integrated Fit Checker
Silicone Facepiece
Model Assay Certificate: TM570
Assigned Protection Factor: 10

- Fit Checker
- Freeposition Underchin design
- Silicone seal
- Mighty Micron Filter
| Collection Efficiency | 95.0% or higher (Average 98.6%) |
|---|---|
| Inhalation Resistance | 80Pa or less (Average 66Pa) |
| Exhalation Resistance | 60Pa or less (Average 28Pa) |
| Resistance Increase | ― (Average 107Pa) |
| Weight | 129g or less (Average 113g) |
| Harness | RB Type |
Replacement Parts
- Inhalation Valve (Oval small type)
- Exhalation Valve (T-6K type)
- Moisture Sponge (Egg-shaped)