Hakaru
Hakaru DP3–M Digital Panel Meter Thermocouple Thermometer

Manufacturer: HAKARU PLUS CORPORATION
Model: DP3–M
96 × 48, Display only, with input–power supply isolation
Model
DP3(1)M-(2)-(3)
(1) Measuring Sensor Temperature Range
| Code | Description |
|---|---|
| 01 | R: 400 to 1600°C |
| 02 | K: 0 to 1200°C |
| 04 | J: 0 to 300°C |
| 05 | T: 0 to 400°C |
(2) Power Supply
| Code | Description |
|---|---|
| 3 | AC100V, 90 to 132V |
| 5 | AC200V, 180 to 250V |
| 9 | DC24V ±10% |
(3) Display Color
| Code | Description |
|---|---|
| No code | Red LED |
| G | Green LED |
How to Order Example
Model: DP302M-3-G
Special Specification:
Device Specifications
Mounting: Panel-embedded type
Housing: Black plastic
Wiring connection: M3 screw terminal
Display Section
- Numeric range: 0 to 199
- Display element: LED red or LED green, digit height 14.2mm
- Negative polarity input: “−” display
- Input overrange: 1□□ display, where □ indicates blank
Scaling function: None
Hold: Data is held when the HOLD screw terminal and COM screw terminal are shorted.
Resolution: 1°C
Sampling period: Approx. 2.5 times/second
Isolation: Between input and power supply
Input type: Single-ended floating input
A/D conversion section: Double integration method
Unit seal: Included
Installation Specifications
Power supply:
- AC power supply: AC90 to 132V, AC180 to 264V, 50/60Hz, approx. 2VA
- DC power supply: DC24V ±10%, 70mA
Power consumption:
- AC90 to 132V, AC180 to 264V: Approx. 2VA
- DC24V: 70mA
Operating temperature range: 0 to 50°C
Storage temperature: -20 to 70°C
Dimensions: W96 × H48 × D90
Mass: AC power supply approx. 300g, DC power supply approx. 200g
Performance
Reference accuracy:
| Type Temperature Range | Reference Accuracy Displayed as % of Reading Value |
|---|---|
| 01: R, 400 to 1600°C | ±(0.3% +3°C) |
| 02: K, 0 to 1200°C | ±(0.3% +2°C), 400°C or lower |
| ±(0.3% +3°C), 400°C or higher | |
| 04: J, 0 to 300°C | ±(0.3% +2°C) |
| 05: T, 0 to 400°C |
Temperature coefficient: ±300ppm/°C
Noise rejection ratio:
- Normal mode: 40dB or more
- Common mode: 110dB or more
Insulation resistance: DC500V, 100MΩ or more
Dielectric strength:
- Between input and external case: AC1500V for 1 minute
- Between power supply and external case: AC1500V for 1 minute
- Between input and power supply: AC1500V for 1 minute, AC power supply
- Between input and power supply: AC500V for 1 minute, DC power supply
Connection Diagram

Outline Drawing
Mounting Dimensions Drawing (Unit: mm)