| Operating Environment | Place of installation | Indoor or outdoor |
|---|---|---|
| Temperature | 0~40°C | |
| Raw Water | Water temperature | 0~40°C (No freezing) |
| Water quality | Iron: up to 12mg/L, Manganese: up to 2mg/L | |
| General Conditions of Use | Filter material type | Iron removal: Toyolex (Air catalytic oxidation) Manganese removal: Ferrolite (Chlorine catalytic oxidation) Iron+Manganese removal: Anthracite+Ferrolite (Chlorine catalytic oxidation) |
| Filtration velocity | SV5~10m/h−1 | |
| Max. operating press. | 0.3 MPa | |
| Treated Water | Water quality | Iron: not more than 0.3mg/L Manganese: not more than 0.05mg/L |
| Backwash Water | Backwash velocity | LV20~40m/h |
Tohkemy Corporation
Tohkemy Iron And Manganese Removal Water Treatment Systems


Manufacturer: Tohkemy Corporation
Model: Iron And Manganese Removal
Filter Media
Manganese Manganese Sand
Ferrolite HC
Toyolex F
Mechanism of Chlorine Catalytic Oxidation
Manganese ions in raw water are removed by being oxidized by sodium hypochlorite using manganese dioxide on the filter media surface as a catalyst, then adhering to the filter media as manganese dioxide. Caution is required as the filter media becomes inactive if the sodium hypochlorite concentration in the water becomes insufficient.
Mechanism of Air Catalytic Oxidation
This contact oxidation filter media utilizes dissolved oxygen without employing oxidizing agents such as sodium hypochlorite. By avoiding chemical use, it helps reduce operating costs. It is also effective in environments where residual chlorine in treated water is undesirable.
Product Specifications

Related Products
-

Tohkemy Relief Valve Back Pressure Valve And Anti Siphonage Valve Pump Accessories
-

Tohkemy LPC Batch-Type Automatic pH Neutralizer Model Water Treatment Systems
-

Tohkemy Filtration Sand Turbidity And SS Removal Filter Media
-

Tohkemy CMD-G Chemical Pump
-

Tohkemy SMF Vessel System Water Treatment Systems
-

Tohkemy DulcoFlow Pump Accessories