| Model No. | Power | Rotation speed (min-1) | 2-Blade pitched paddle | Shaft (mm) | Maximum agitating capacity (m3) | ||||
|---|---|---|---|---|---|---|---|---|---|
| Output (kW) | Number of poles (P) | 50Hz | 60Hz | Paddle diameter φD | Shaft diameter φd | Standard length L | Dilute liquid | Medium viscosity liquid | |
| NTG4-001-15 | 0.1 | 4 | 96.7 | 117 | 300 | 20 | 1,200 | 0.7 | 0.24 |
| -001-21 | 69.0 | 83.3 | 350 | ||||||
| -001-29 | 50.0 | 60.3 | 450 | 0.9 | 0.32 | ||||
| -001-35 | 41.4 | 50.0 | 550 | 1.2 | 0.4 | ||||
| -001-43 | 33.7 | 40.7 | 600 | ||||||
| -001-51 | 28.4 | 34.3 | 650 | ||||||
| NTG4-002-15 | 0.2 | 4 | 96.7 | 117 | 350 | 20 | 1,200 | 1.3 | 0.44 |
| -002-21 | 69.0 | 83.3 | 450 | 1,300 | |||||
| -002-29 | 50.0 | 60.3 | 550 | 25 | 1,500 | 1.4 | 0.48 | ||
| -002-35 | 41.4 | 50.0 | 600 | 1.8 | 0.64 | ||||
| -002-43 | 33.7 | 40.7 | 700 | ||||||
| -002-51 | 28.4 | 34.3 | 750 | ||||||
| NTG4-004-15 | 0.4 | 4 | 96.7 | 117 | 400 | 25 | 1,300 | 2.4 | 0.8 |
| -004-21 | 69.0 | 83.3 | 500 | 1,500 | |||||
The standard motor is Sumitomo’s totally-enclosed fan-cooled outdoor motor with 3-phase 200V 50Hz, 200 / 220V 60Hz. A single-phase 100V is also available.
The standard impeller is a 2 stages of 2-blade pitched paddle, but the blade shape may be changed depending on the purpose and_ specifications.
The viscosity of dilute liquid is less than 0.1 Pa · s (100 cP), and medium-viscosity liquid is about 0.1 to 0.5 Pa · s (100 to 500 cP).
Please select NTC model for 0.75kW or larger.