KOKEN LTD.
Koken BL-1180H Dust Respirator

Manufacturer: KOKEN LTD.
Model: BL-1180H
Usable for a wide variety of tasks!
Replaceable Dust Respirator
Sakai Model BL-1180H
The BL-1180H is the highest-performing dust respirator in our protective mask lineup, featuring an RL3 classification (particle collection efficiency over 99.9%).
This mask can be used for both indoor and outdoor construction site operations. Featuring replaceable filters, it fits the profile of a half-face dust mask. Additionally, the filter can be swapped with a chemical cartridge for use as a gas mask in toxic environments.
![]() | ![]() |
| National Model Assay Certificate No. TM788 | Alpha Ring Filter Model RD-8 |
RL3
Primary Applications
- Asbestos removal operations (Level 1 tasks) ※1
- Indium compound manufacturing and handling operations
- Dioxin handling operations
- Welding operations
- Grinding operations
Note: Usage may be restricted depending on conditions such as workplace concentration levels.
For details, please refer to the “Examples of Applicable Work” below.
Examples of Applicable Work
Dust types and work descriptions
- Work with risk of Dioxin exposure:
Level 1 tasks utilizing asbestos removal masks classified under “Category 3” or “Category 4” for asbestos abatement. - Indium compound manufacturing and handling:
Tasks where indium compound concentrations are below 3 µg/m³. - Metal-related operations:
Tasks generating metal fumes (including welding fumes) in areas where metal fumes are present. - Work generating dust from substances with concentrations below 0.1 mg/m³:
Tasks in areas where dust is generated from substances at concentrations lower than 0.1 mg/m³.
※1: When removing Level 1 plasterboards using cutting methods, powered air-purifying respirators (PAPR) must be used.
※2: Welding operations requiring a protection factor below 10.
Replace Filter with a Chemical Cartridge for Gas Mask Usage
Painting, washing, and degreasing operations, as well as solvent handling tasks.
By exchanging the filter for an absorbent cartridge, it can be used as a G-7 Gas Mask.
National Model Assay Certificate No. TN382.
![]() | ![]() |
| When KGC-10C Cartridge is attached | KGC-10C-03 Organic Vapor Cartridge Select the appropriate cartridge based on the specific gases and vapors in the environment. See the back page for “Compatible Cartridge Types”. |
Respirator Features
For the 1180H model equipped with the Fit Checker, simply pull the lever to perform an immediate Fit Check.
Pull up the Fit Checker and instantly test for leaks!
Even with a high-efficiency filter, wearing the mask incorrectly negates its protective value. With the integrated Fit Checker model, a simple lever operation is all it takes to perform a user seal check, making fit verification fast and easy.

Facepiece contact area designed for optimal fit
Skin-friendly silicone material
The silicone facepiece reduces skin irritation and is less likely to cause dryness. This material remains highly flexible, accommodating facial movements to provide a stable and comfortable fit.
Freeposition Underchin
A specialized design providing an optimal facial contact shape.
By adjusting the nose section first and then securing the chin area, the mask accommodates varying face sizes, preventing leaks in vulnerable areas such as the bridge of the nose.

Respirator Performance Specifications
| Dust Respirator | ||
|---|---|---|
| Model Name (Product Code) | Sakai Model 1180H | |
| National Assay Certificate | No. TM788 | |
| Filter Material | Alpha Ring Filter Model RD-8 | |
| Classification | Replaceable Type ・ Direct Connection | |
| Respirator Type | Half-face | |
| Performance (Classification) | RL3 | |
| Assigned Protection Factor | 10 | |
| Internal Standard | Particle Collection Efficiency | Above 99.9% |
| Inhalation Resistance | Below 88Pa (including filter) | |
| Exhalation Resistance | Below 45Pa | |
| CO2 Concentration Increase | Below 0.5% | |
| Weight | Below 134g (including filter) | |
| Inhalation Resistance Increase (Average) | 89Pa | |
The figures above indicate the performance when using the standard product (Size M mask, RB type harness) without any accessories/options attached.
Masks are available in two sizes: Size M (Standard) and Size S.
Compatible Filters
| Filter Name | Model Name When Attached | Dust Protection (Classification) |
|---|---|---|
| Alpha Ring Filter Model RD-8 (Included) | Sakai Model 1180H No. TM788 | RL3 |
| Alpha Ring Filter Model LAS-51 (Sold separately) | Sakai Model 1180-05 No. TM538 | RL2 |
The 1180H model can be used as the 1180-05 model dust respirator by replacing the filter with the LAS-51 Alpha Ring Filter. Please check the instruction manual for applicable operations.
Compatible Chemical Cartridges (Sold Separately)
| Target Gas Type | Cartridge Name | Dust Protection (Classification) |
|---|---|---|
| For Halogen Gases | KGC-10A-03 For Halogen Gases | —– |
| KGC-10A-03 For Halogen Gases When Mighty Micron Filter is attached | Yes (S1) ※1※3 | |
| For Acid Gases | KGC-10B-03 For Acid Gases | —– |
| KGC-10B-03 For Acid Gases When Mighty Micron Filter is attached | Yes ※1※2※3 | |
| For Organic Vapors | KGC-10C-03 For Organic Vapors | —– |
| KGC-10C-03 For Organic Vapors When Mighty Micron Filter is attached | Yes (S1) ※1※3 | |
| Model KGC-10 L For Organic Vapors (C) | —– | |
| Model KGC-10 L For Organic Vapors (C) When Mighty Micron Filter is attached | Yes (S1) ※1※3 | |
| KGC-10MC-04 For Organic Vapors ・ Dust | Yes (S1) ※1※3 | |
| Model KGC-10 LMC-02 For Organic Vapors ・ Dust | Yes (S1) ※1※3 | |
| For Ethylene Oxide | KGC-10EOG (Pack of 5) For Ethylene Oxide | —– |
| For Formaldehyde | KGC-10FA-03 (Pack of 5) For Formaldehyde | —– |
| For Formaldehyde ・ Organic Vapors | Model KGC-10 L FA For Formaldehyde ・ Organic Vapors | —– |
| Model KGC-10 L FA For Formaldehyde ・ Organic Vapors When Mighty Micron Filter is attached | Yes (S1) ※1※3 |
※1 Attached to the chemical cartridge for use against dust mixed in toxic gases or vapors.
※2 Represents a testing standard equivalent to “Class S1” of the national assay regulations.
※3 The Assigned Protection Factor against dust, etc., is “4”.