Japan, Measuring Instrument
OSC92OT108 3 – Component Load Cell, Mz Torque up Type

Model: OSC92OT108
Features
– High measuring resolution of 1/10000
– High accuracy by matrix operation possible
– High stability against temperature
Specifications
| Model | OSC 92OT108 | |||||||||
| Rated output | Approx. 0.5mV/V(approx. 1000×10-6 strain) | |||||||||
| for each component force | ||||||||||
| Non-linearity | +/-0.2%FS for each component force | |||||||||
| Hysteresis | +/-0.2%FS for each component force | |||||||||
| Allowed overload | +/-150%FS for each component force | |||||||||
| Cross talk* | -Between Fx, Fy | : +/-2%FS/FS | ||||||||
| -Fx, Fy by Mz | : +/-3%FS/FS | |||||||||
| -Mz by Fx, Fy | : +/-2%FS/FS | |||||||||
| – By Mx, My | : +/-3%FS/FS | |||||||||
| Temperature influence on the zero point | +/-0.01%FS/deg.C | |||||||||
| for each component force | ||||||||||
| Temperature influence on the sensitivity | +/-0.05%Reading/deg.C | |||||||||
| for each component force | ||||||||||
| Cable connection | NDI connector length = 5m | |||||||||