- For small and lightweight workpieces, if the workpiece does not release due to residual magnetism when relying only on its own weight, this model is effective.
- A pin at the center of the holding surface automatically releases the workpiece from residual magnetic attraction by spring pressure.
Duty Cycle: Continuous 100% ED
※ The maximum holding force is the maximum value obtained with full-surface contact using an SS400 steel test plate, 10 mm thick, with a ground-finished surface.
Common Bottom Surface
| Model | Dimensions (mm) | Maximum Holding Force (N) | Mounting Holes (mm) | Voltage (V) | Current (A) | Weight (g) | |
|---|---|---|---|---|---|---|---|
| Mounting Screw Hole | Anti-Rotation Hole | ||||||
| CEH-20R | φ20 × 25 | 4.9 (0.5 kgf) | M4 × 0.8 Depth 5 | φ2.1 Depth 2.5 | DC24 | 0.04 | 35 |
CEH-30R![]() | φ30 × 25 | 29 (3 kgf) | M6 × 1.0 Depth 12 | φ4 Depth 2 | 0.085 | 100 | |
CEH-40R![]() | φ40 × 25 | 108 (11 kgf) | φ4 Depth 2.5 | 0.13 | 160 | ||
Operating Conditions for Electromagnetic Holders
[Allowable Temperature]
Use the holder at an ambient temperature of 40°C or less and with the workpiece temperature at 50°C or less. If you plan to use it in a higher-temperature environment, please consult us in advance.
[Holding Force]
The holding force varies depending on conditions such as the material, shape, surface finish, and plate thickness of the workpiece. In addition, if full-surface contact is not possible, the workpiece cannot be held at its center of gravity, or strong impacts occur during transport, select a model with an appropriate safety margin. Please consult us in advance regarding specific operating conditions.
[Waterproofing / Rust Prevention]
The electromagnetic holder is not waterproof. Furthermore, the holding surface does not have a rust-prevention treatment, so it cannot be used in environments such as clean rooms. However, custom specifications suitable for such environments are also available. Please consult us for details.
[Residual Magnetic Attraction]
Even after switching the power OFF, a small amount of residual magnetic holding force remains. If the mass of the held object exceeds this residual magnetic force, it will not cause a problem. However, in other cases, models other than the automatic release type (CEH-R) require a demagnetizing rectifier (TPRC-R) equipped with a reverse-excitation magnetic circuit.