Toyo Machinery Co.
Toyo Machinery VMC-15 Modular Process Control System OptiPac

Manufacturer: Toyo Machinery Co., Ltd.
Model: VMC-15
Features
Operators can connect various sensors as needed to measure manufacturing and processing control parameters for sheet products—such as residual moisture content, exhaust humidity, surface temperature, set time, thickness, weight, and density—and use them for process control.
Heat setting time Perm setting VMT
An infrared radiation thermometer (pyrometer) is used. It allows for non-contact measurement of the surface temperature of the web being passed through, enabling control of the time it takes from reaching the set temperature until it exits the dryer.

Density Pharmacont PMC
This uses either a photoelectric sensor or a camera sensor. PharmaCont PMC determines fabric density by processing signals from a non-contact photoelectric sensor or image sensor.

Residual moisture content (RMS)
This is an electrical resistance measurement method. The electrodes used to measure electrical resistance determine the residual moisture content at the dryer outlet.

Exhaust Humidity Eco Mat AML
A water vapor measurement sensor is used. Ecomat AML monitors the exhaust humidity to maintain appropriate levels by controlling the exhaust fan speed or exhaust damper, and adjusts thermal energy consumption to match actual demand.