Features
- Compact structure
Compact, lightweight and high panel installation density - Options
The options of heater disconnection alarm function and current limit function are available. - Phase-angle firing/zero-cross firing
The phase-angle firing system and the zero-cross firing system are selectable. The running by the phase-angle firing system at the initial stage and by the zero-cross firing system at the normal stage is possible. - Zero-cross firing system
With the delta-sigma modulation, which controls every 1 cycle, the fine control like the phase-angle firing system is possible. - Setting unit (option)
Display of various parameters, voltage/current/ power and change of the feedback system are possible. - Various protections functions built-in
The rapid fuse melts to protect the thyristor element from load short-circuits, and the gate turns off during over-current. Models with a built-in cooling fan stop output and activate an alarm when the heat-sink temperature becomes abnormal. - Self-diagnosis function built-in
The self-diagnosis function detects abnormal operation, thyristor element issues, and power supply problems.
Specifications
Phase | Single-phase |
---|---|
Rated current | 10, 20, 30, 50, 75, 100, 150, 200, 250, 300, 400, 500, 750, 1000A (to be specified) |
Rated voltage | 100, 110, 120, 200, 220, 240, 380, 400, 440VAC (to be specified) |
Rated frequency | 50/60Hz (automatic change) |
Allowable frequency fluctuation | ±2Hz of rated frequency (±1Hz for performance guarantee) |
Working temperature range | -10 to 55°C (0 to 50°C for performance guarantee) |
Input signal | Selectable on terminals of 4 to 20mADC (internal resistance 100 Ω), 1 to 5VDC (internal resistance 25k Ω), ON-OFF contact signal, and Resistance signal (10k Ω, manual) |
Output range | 0 to 98% of rated voltage |
Minimum load current | 0.5A or more (at 98% output of rated voltage) |
Applicable load | Resistive load, inductive load (primary side control of transformer, phase-angle firing system only) |
Output control system | Phase-angle firing/zero-cross firing (selectable depended on models) |
Over-current protection | Thyristor gate-off (120% or more of rated current, on built-in or external CT) |
Cooling system | Natural cooling for 150A or less of rated current Built-in cooling fan for 200A or more |
Other functions | Soft-start, soft-up/down (1 to 20 seconds), soft-start at power failure recovery |
Dimension | H150 x W70 x D165mm (for 10A, 20A) H352 x W60 x D190mm (for 35A to 75A) H325 x W128 x D190mm (for 100A to 250A) H495 x W128 x D230mm (for 300A to 500A) H495 x W260 x D350mm (for 750A, 1000A) |
Weight | About 2kg for 10A, 20A, about 3kg for 30 to 75A, about 7kg for 100 to 250A, about 12kg for 300 to 500A, about 35kg for 750A, 1000A |
Related Products
-
Namita Kiko NAMI Color (NHC-1000) Anchor metals
-
Japan Clamp S Clamp For Vertical Suspension (With Lock Device)
-
Vessel No.TA20WSQ4L Hard Forged Tilt Socket Adapter With One Half Squared 12.7mm Long
-
Tohnichi QSPLS/CSPLS/QRSPLS/SPLS/SPLS-MH/RSPLS/RSPLS-MH/SPLS-N Interchangeable Head Torque Wrenches
-
Line Seiki DK-5005E Tally Counters
-
Fujii Denko R-500E-S15 Harness & Lanyard