Chino JU Series Single-Phase Thyristor Regulators

Made in Japan
Manufacturer: Chino Corporation
Model: JU Series

Features

  • Compact structure
    Compact, lightweight and high panel installation density
  • Options
    The options of heater disconnection alarm function and current limit function are available.
  • Phase-angle firing/zero-cross firing
    The phase-angle firing system and the zero-cross firing system are selectable. The running by the phase-angle firing system at the initial stage and by the zero-cross firing system at the normal stage is possible.
  • Zero-cross firing system
    With the delta-sigma modulation, which controls every 1 cycle, the fine control like the phase-angle firing system is possible.
  • Setting unit (option)
    Display of various parameters, voltage/current/ power and change of the feedback system are possible.
  • Various protections functions built-in
    The rapid fuse melts to protect the thyristor element from load short-circuits, and the gate turns off during over-current. Models with a built-in cooling fan stop output and activate an alarm when the heat-sink temperature becomes abnormal.
  • Self-diagnosis function built-in
    The self-diagnosis function detects abnormal operation, thyristor element issues, and power supply problems.

 

Specifications

JU Series

PhaseSingle-phase
Rated current10, 20, 30, 50, 75, 100, 150, 200, 250, 300, 400, 500, 750, 1000A (to be specified)
Rated voltage100, 110, 120, 200, 220, 240, 380, 400, 440VAC (to be specified)
Rated frequency50/60Hz (automatic change)
Allowable frequency fluctuation±2Hz of rated frequency (±1Hz for performance guarantee)
Working temperature range-10 to 55°C (0 to 50°C for performance guarantee)
Input signalSelectable on terminals of 4 to 20mADC (internal resistance 100 Ω), 1 to 5VDC (internal resistance 25k Ω), ON-OFF contact signal, and Resistance signal (10k Ω, manual)
Output range0 to 98% of rated voltage
Minimum load current0.5A or more (at 98% output of rated voltage)
Applicable loadResistive load, inductive load (primary side control of transformer, phase-angle firing system only)
Output control systemPhase-angle firing/zero-cross firing (selectable depended on models)
Over-current protectionThyristor gate-off (120% or more of rated current, on built-in or external CT)
Cooling systemNatural cooling for 150A or less of rated current Built-in cooling fan for 200A or more
Other functionsSoft-start, soft-up/down (1 to 20 seconds), soft-start at power failure recovery
DimensionH150 x W70 x D165mm (for 10A, 20A)
H352 x W60 x D190mm (for 35A to 75A)
H325 x W128 x D190mm (for 100A to 250A)
H495 x W128 x D230mm (for 300A to 500A)
H495 x W260 x D350mm (for 750A, 1000A)
WeightAbout 2kg for 10A, 20A, about 3kg for 30 to 75A, about 7kg for 100 to 250A, about 12kg for 300 to 500A, about 35kg for 750A, 1000A