Toyo Keiki
Toyo Keiki SVF-11M AC Voltmeter Rectifier Type
Product Made In Japan
Manufacturer: Toyo Keiki
Model: SVF-11M Rectifier Type
Features
1. A long scale meter for indicating wide angles.
2. A stepped scale plate removes any level difference between the scale and the tip of the needle, resulting in accurate readings.
3. Meter that has a bright scale due to the wide-cover lighting surface.
4. It is not affected by steel panels.
5. Can be manufactured with EL board (Electro-Luminescence Board) lighting.
6. The terminal cover is now equipped as standard.
7. It is now compatible with multi-setting set pointer models.
Remarks
Note Outside Dimensions
SVF-11M
Using VT
Use combined VT and 150V meter if 600V is exceeded.
Usage example Meter: Scale 0~9000V, input 0~150V
VT:6600V/110V
Frequency
Indicate the frequency when measuring AC voltage outside of commercial frequencies. (JIS mark not indicated)
(Can be manufactured from approximately 30Hz to 10kHz, but limited to sine waves.)
Meter Sensitivity
Standard AC voltmeter sensitivity is 1mA (1kΩ/V), but high-sensitivity meters can also be manufactured.
Waveform Distortion
If there is waveform distortion, use an electronic device type (SeVF type: M.R.S.-Response P10) that is less influenced by waveform distortion.
Scale Calibration
Conducted via sine waves.
Specifications
Measurement Range Value | SVF-11M | Note | |
---|---|---|---|
Current Consumption | Series Resistor | ||
3 V 5 V 7.5 V 10 V 15 V 30 V 50 V 75 V 100 V 150 V 300 V 600 V |
AC1 mA | Built-in | Direct Measurement |
601 V 20 kV | VT combined | Use a combination of 150V meter and VT | |
Weight | Approx. 0.45kg |
Dimensions
Connection Diagram
For Direct Measurement (If 600V or below)