Toyo Keiki
TOYO KEIKI TGP Series rpm Transducer
Product Made In Japan
Manufacturer: Toyo Keiki
Model: TGP Series
TGP-□
TGP-□S: Slow pulse input type
TGP-□D: With power supply for sensor
A transducer that outputs a DC signal in proportion to AC signal and pulse sequence signal frequency.
A combination alternating current device generator and pulse encoder that supplies a direct current signal in proportion to the number of revolutions and the speed.
Plug-in type makes upkeep and configuration changes simple.
Improved reliability and greater compactness through the use of custom ICs.
The rared output can be adjusted if 50% over the operating range.
Photo couple provides complete insulation between input and output.
Specification
INPUT | OUTPUT | AUXILIARY POWER SUPPLY |
---|---|---|
3 standard type of sensor and 7 standard type of input are available | 8 standard type of output are available | AC 100/110V ±10% 50/60Hz approx. 3.5 VA AC 200/220V ±10% 50/60Hz approx. 3.5 VA DC 24V ±10% approx. 3 W DC 100/110V ±10% approx. 3.5 W types are immediately available. For types not listed above contact a company representative. |
Available with frequency input range: 9Hz~30kHz Available with sensor range AC voltage: below 200Vrms Voltage pulse: below 50V Contact signal: below 15V, 10mA |
Available with Max. voltage output 10V (600Ω~∞) Max. current output 20mA (0~500Ω) |
SPECIFICATION | ATTENTION |
---|---|
Input frequency is a slow pulse specification of below 25Hz. Either slow pulse specification electric pulse or contact signal can become the input. | When the input frequency is simultaneously converted output overshoot of about 5% may occur. When the input signal is AC there may be no response at voltages of less than 5%. |
Specified Character
(1) Tolerance
±0.5% of output span. (Ambient temperature 23℃)
Not providing of below 5% at input range (TGP-□,TGP-□D)
Not providing of below 10% at input range (TGP-□S)
(2) Effect of temperature
Within ±0.5% of output span. (For 23℃±10℃ variations)
(3) Effect of auxiliary power supply
Within ±0.25% of output span. (For rated voltage ±10% variations)
(4) Effect of load resistance
Within ±0.05% of output span. (For load resistance range)
(5) Output ripple
Within 0.5%p-p of output span.
(6) Response time (Time to 99% output)
Input : abov 100Hz Shorter than 1sec. 50Hz~100Hz Shorter than 2sec.
below 50Hz Shorter than 3sec.
(7) Dielectric strength
2000V AC,1min. (50/60Hz)
(Between input,output,auxiliary power supply and external case)
(8) Insulation resistance
Higher than 100MΩ at 500V megger.
(Between input,output,auxiliary power supply and external case)
(9) Power supply for sensor (TGP-□D only)
DC 12V ±1V,max.30mA
(10) Weight
Approx.410g
Connection Diagram
DESIGNATION ITEM AT ORDER
ORDER EXAMPLE
① TGP-1-12-8 SENSOR AC 30V
② CGP-2-29-9 INPUT : 0~150Hz,SENSOR DC 12V,OUTPUT : DC 0~7V
※For special specifications please consult company representatives.