Manufacturer: TPR Osaka Seimitsu Kikai Co., Ltd.
Model : CLP series
Features
- A fully automatic gear measuring machine suitable for measuring the accuracy of gears used under high loads, such as transmissions in automobiles and construction machinery.
- A standard model that also supports measurement of spur gears, helical gears, and various tools.
Model | CLP-15SF | CLP-35SF | CLP-65SF | CLP-85F | CLP-120F |
---|
Features | A compact machine specialized for small modules | Standard model of gear measuring machine | A medium-sized machine that can rotate heavy objects stably thanks to its enhanced torque. | Large-scale measuring machine for heavy loads such as gears for heavy machinery | Large-scale measuring machine for special gears with a maximum outer diameter of 1200 mm |
Module (mm) | 0.2-5 (0.1~) | 0.5-12 (0.1~) | 0.5-12 | 0.5-20 | 1-25 |
Maximum outer diameter (mm) | 150 | 350 | 650 | 850 | 1,250 |
Maximum weight (kg) | 50 | 300 | 350 | 200 | 3,000 |
3D probe compatible | × | × | × | × | × |
CLP-35SF

■Gear Measurement
Measurement Module | 0.5–12 mm (Option 0.1 and above) |
Maximum measurement gear outer diameter | 350 mm |
Maximum measurement face width length | 400 mm |
Measurement gear shaft length | 30 to 600 mm (Option: up to 800 mm) |
Maximum measured gear weight | 300 kg |
■External view and layout diagram

CLP-15SF

■Gear Measurement
Measurement Module | 0.2 to 5 mm(Option 0.1 and above) |
Maximum measurement gear outer diameter | 150 mm |
Maximum measurement face width length | 200 mm |
Measurement gear shaft length | 300 mm(Option: up to 500mm) |
Maximum measured gear weight | 50 kg |
■External view and layout diagram

Specification of CLP-15SF/CLP-35SF
Item | CLP-15SF | CLP-35SF |
---|
Measuring Item | Tooth profile, lead, pitch(single, adjacent and cumulative) and runout for spur and helical gear (Incl. internal gear) |
Standard software | ●Fine dividing measurement of tooth surface and its output ●Successive measurement of counter shaft gears ●Three-dimensional display of tooth surface ●Output of comparison data before and after heat treatment (Overwriting) ●ISO, JIS, DIN and AGMA classification etc. |
Module (with optional spec) | m0.2 ~ 5 (m0.1 ~ 5) | m0.5 ~ 12 (m0.1 ~ 12) |
Number of teeth | 10 ~ 500 |
Gear outer diameter | Max φ150mm | Max φ350mm |
Base circle diameter | 0 ~ φ130mm | 0 ~ φ300mm |
Tooth width | Max 200mm | Max 400mm |
Tangent length for profile measurement | ±50mm | ±120mm |
Helix angle (with optional equipment) | 0°~ ±65° ( ±65°~ ±90°) |
Gear shaft length (with optional spec) | 0 ~ 300mm (0 ~ 500mm) | 30 ~ 600mm (30 ~ 800mm) |
Gear weight | Max 50kg | Max 300kg |
Resolution | 0.0001mm |
Power supply | AC 100V ±10% (50/60Hz ±1Hz) |
Capacitance | 2KVA |
Machine weight | 0.8t | 1.3t |
Dimensions of machine (W x D x H) mm | 842.5×893×1670 | 1095×1032×1935 (1095×1007×2042) |
CLP-65SF

■Gear Measurement
Measurement Module | 0.5 to 20 mm |
Maximum measurement gear outer diameter | 650 mm |
Maximum measurement face width length | 400 mm |
Measurement gear shaft length | 50 to 800 mm(Option: up to 1,000mm) |
Maximum measured gear weight | 350 kg |
■External view and layout diagram

CLP-85F

■Gear Measurement
Measurement Module | 0.5 to 20 mm |
Maximum measurement gear outer diameter | 850 mm |
Maximum measurement face width length | 400 mm |
Measurement gear shaft length | 50 to 800 mm(Option: up to 1,000mm) |
Maximum measured gear weight | 200 kg |
■External view and layout diagram

CLP-120F

■Gear Measurement
Measurement Module | 1 to 25 mm |
Maximum measurement gear outer diameter | 1,250 mm |
Maximum measurement face width length | 600mm |
Measurement gear shaft length | 200–1,200 mm(Option: up to 1,500mm) |
Maximum measured gear weight | 3,000 kg |
■External view and layout diagram