Features
- Separate-interchangeable probes available with a main unit.
- Selections of probe for ferrous (electro-magnetic) or non-ferrous ( eddy current) substrate depending on a measuring object.
- Capability of selections probe like high-stable probe to measure minute piece objects or alike depending on applications and a measurement range.
Specification
Models | Fe-2.5※1/2.5L | Fe-2.5LwA | Fe-0.6Pen |
Methods | Magnetic inducing type | ||
Ranges | 0~2.50mm | 0~600μm | |
Display resolutions | 1μm:0~999μm switching to 0.1μm:0~400μm 0.5μm:400~500μm 0.01mm:1.00~2.50mm |
1μm:0~600μm switching to 0.1μm:0~400μm 0.5μm:401~500μm |
|
Accuracies (perpendicularly testing on flat face) |
0~100μm:±1μm or ±2% the reading value 101μm~2.50mm:±2% 0~100μm:±1μm or ±2% the reading value 101μm~600μm: ±2% the reading value |
||
Probes | One point contact constant pressure type, V cut 2.5:φ15×47mm 2.5L:18x23x67mm |
One point contact constant pressure type, Measuring part:About 20x57mm Total Length: about 550~1,540mm (flexible) |
One point contact constant pressure type, V cut φ5.6×92.2mm |
V type probe adaptors※2 /Non |
Non | ||
Accessories | Standard thickness, Zero plate for testing (Fe) |
Standard thickness, Zero plate for testing (Fe) Carrying case |
Standard thickness, Zero plate for testing (Fe) |
Measuring objects | Coating, lining, thermal spray films, plating (except electrolyte nickel plating) etc. on magnetic metal substrate like iron, steel. | Coating, lining, plating on high/hard-to-reach/remote place on magnetic metal substrate like iron, steel. | Coating, lining, plating on a narrow/small place and part substrate like iron, steel. |
1.Probes are heat-resistant (about 200℃). (Fe-2..5)
2.V type probe adaptors (3 kinds: lessΦ5, Φ5~10, Φ10~20) can be used with Fe-2.5.
Models | Fe-10 | Fe-20 | |
Methods | Magnetic inducing type | ||
Ranges | 0~10mm | 0~20mm | |
Display resolutions | 1μm:0~999μm 0.01mm:1~10mm |
1μm:0~999μm 0.01mm:1~5mm 0.1mm:5~20mm |
|
Accuracies (perpendicularly testing on flat face) |
0~3mm:±(5μm + 3% the read value) Over or 3.01mm:±3% the read value |
||
Probes | One point contact constant pressure type, V cut φ18x47mm |
One point contact constant pressure type, V cut φ35x55mm |
|
Accessories | Standard thickness, Zero plate for testing (Fe) |
||
Measuring objects | Relatively thicker objects | Thick objects |
Probe must be ordered separately.