Hakaru
Hakaru XS3-110 New Electronic Multimeter

Manufacturer: HAKARU PLUS CORPORATION
Model: XS3-110
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
Product Description
The “XS2-110 Electronic Multimeter,” which was launched in 2012, will be revamped as the “XS3-110.”
While retaining the functionality of the XS2-110, we have added new features to make the XS3-110 easier to use.
(The screens shown are from a product under development.)
Features
- In order to display more information, part of the screen has been changed to a full dot area. Characters and symbols can be displayed, so the settings are displayed when manually setting.
- By scanning the 2D code, device information such as model name and serial number, as well as a link to the download page for this page’s materials, will be displayed. *Patented
- The PC setting connector has been changed to USB TYPE-C, so that it can be set up via USB power supply. *Utility model no. 3250122
- The shape of the switch has been changed to make it easier to operate.
- To make it easier to see the terminal names and device numbers, the molding color of the case body has been changed from black to ivory.
- Some of the special products we produced in the past have been standardized.
- The backlight is now available in two colors: amber and white (green and orange have been discontinued).
Specification
Specification
| item | specification |
|---|---|
| phase wire system | (Model specification) Single-phase 2-wire, single-phase 3-wire, 3-phase 3-wire (setting switch) |
| Voltage Input | ・AC110V, AC220V (setting switch) |
| Current Input | ・5A |
| Auxiliary power supply | ・AC85~264V or DC85~143V |
Digital display
| Measurement item (number of digits) | Input Rating | inherent error | remarks |
|---|---|---|---|
| Current (3・4) | 0~1A・0~5A | ±0.5% | Display unit A/kA switching |
| Line voltage (3, 4) | 0~150V・0~300V | ±0.5% | Display unit V/kV switching |
| Electricity (4) | 0~1kW・-1~0~1kW・0~2kW・-2~0~2kW | ±0.5% | Display unit switchable between W, kW and MW, negative display |
| Reactive Power (4) | 0~Lag1kvar・Lead1~0~Lag1kvar・0~Lag2kvar・Lead2~0~Lag2kvar | ±0.5% | Display units: var, kvar, Mvar switchable, with Lag and Lead display |
| Power factor (4) | Lead50~100~Lag50・Lead0~100~Lag0(%) | ±2.0% | Lag/Lead display, 1 decimal place |
| Electricity (6) | Digital display: multiplication factor x 1, x 10, x 100, x 1000 | ±2.0% ±2.5% | 5 to 120% of rated current (power factor = 1)10 to 120% of rated current (power factor = 0.5) |
| Reactive energy (6) | Digital display: multiplication factor x 1, x 10, x 100, x 1000 | ±2.5% ±2.5% ±3.0% | 10 to 120% of rated current (power factor = 0)20 to 120% of rated current (power factor = 0.866) 10% of rated current |
| Frequency (3) | 45~65Hz・45~55Hz・55~65Hz・ | ±0.5% | 1 decimal place |
| Demand current Maximum demand current (3/4) | 0~5A | ±0.5% | Demand time selection setting, heat conduction root calculation method |
| Demand power Maximum demand power (4) | 0~1kW・0~2kW | ±0.5% | Demand time selection setting, heat conduction root calculation method |
Communication specifications
| method | item | Rating |
|---|---|---|
| RS-485 communication | Interface | RS-485 |
| 〃 | Transmission distance | Less than 1km (maximum 32 cars) |
| 〃 | communication speed | 1200・2400・4800・9600・19200bps |
| 〃 | Transmission cable | Shielded twisted pair wire (CPEV-S0.9φ) |
| 〃 | Termination resistor | Built-in 100Ω (terminal short-circuited to turn on termination resistor) |
| 〃 | Synchronization method | Start-stop synchronization method |
| 〃 | Communication Control Method | Polling selection method (half-duplex) |
| 〃 | Code used | ASCII |
| 〃 | Data format: Starbit | 1 bit |
| 〃 | Data method: Data | 7-bit |
| 〃 | Data format: Parity bit | even number |
| 〃 | Data format: Stop bit | 1 bit |
| RS-485 communication (Modbus) | Interface | RS-485 communication (Modbus) |
| 〃 | Transmission distance | Less than 1km (maximum 32 cars) |
| 〃 | communication speed | 1200・2400・4800・9600・19200bps |
| 〃 | Transmission cable | Shielded twisted pair wire (recommended: CPEV-S0.9φ) |
| 〃 | Termination resistor | Built-in 100Ω (terminal short-circuited to turn on termination resistor) |
| 〃 | Synchronization method | Start-stop synchronization method |
| 〃 | Communication Control Method | Polling selection method (half-duplex) |
| 〃 | Code used | RTU |
| 〃 | Data format: Starbit | 1 bit |
| 〃 | Data method: Data | 8-bit |
| 〃 | Data format: Parity bit | None or even number or odd number |
| 〃 | Data format: Stop bit | 1 or 2 bits |
Related Products
-

Hakaru HPA-44 PC Application For Setting New Electronic Multimeters
-

Hakaru XSTC-110 Battery-Operated Fault Indicator
-

Hakaru XT-110 Fault Indicator
-

Hakaru HLR-A8 LoRa Radio Analog 8-Point Input Model
-

Hakaru XST-110 Fault Indicator With Buzzer
-

Hakaru XM2-110-6 Electronic Multimeter, Isolated Measurement