Hakaru XM2-110-9 High-Performance (Single-Phase Two-Wire, Single-Phase Three-Wire, Three-Phase Three-Wire)

Manufacturer: HAKARU PLUS CORPORATION
Model: XM2-110-9

Product Description

The high-performance electronic multimeter XM2-110 is a digital instrument that combines an indicating instrument and a converter.
Up to four measurement elements can be displayed at once: one bar graph and three digital displays.
The size is a 110mm square cylindrical body with a depth of 89mm, making it thin and compact.
The LCD panel uses the STN method, achieving higher contrast and a wider viewing angle than conventional products.

Features

Four measurement items, including a bar graph (with digital display) and three digital displays, can be displayed simultaneously on the LCD panel.
Measurement items that were previously measured using multiple mechanical instruments can now be consolidated into one unit.
Display items can be set as desired.
Display items: Current, Voltage (Line voltage, Phase voltage), Power, Reactive power, Power factor, Energy, Reactive energy, Frequency, Demand current, Maximum demand current, Demand power, Maximum demand power, Extended current measurement, Harmonic current, Harmonic voltage, Zero-phase voltage, Maximum zero-phase voltage, Io, Ior
With a wide viewing angle of 75° up and down and 70° left and right, it can be installed anywhere.
The internal structure has been redesigned to make it thinner and more compact, with a depth of just 89mm. In addition to the conventional button operation settings, by utilizing the dedicated PC setting software, various parameters can be instantly set without operating the keys on the main unit, even when setting up multiple meters. In addition, the settings can be saved and read, making maintenance easier.
The LCD panel allows you to set the backlight automatic shut-off time and adjust the brightness.
The output test function allows for a simulated output signal to be sent externally, even without input, as long as there is a power supply.

  • Analog output: Zero/span output operation possible
  • Pulse output: Output operation possible for each pulse
  • Alarm output: Alarm output ON/OFF switching operation possible
  • Communication output: Transmission data output operation possible

The phase detection function makes it easy to check the voltage phase sequence and CT direction, making it ideal for sites where mechanical instruments are used.
You can choose from four backlight colors to suit your site: amber (standard), white, orange, and green.
Measurements can be made for single-phase two-wire, single-phase three-wire, and three-phase three-wire (selectable settings).
It can measure harmonics (current and voltage) up to the 15th order and convert it into 5th order measurements.
Depending on the model, the following optional functions can be installed: Simultaneous installation of

  • 4 analog outputs, pulse output, and alarm output
  • RS-485 + contact status input x 3 points, pulse output, and alarm output
  • RS-485 communication (Modbus/RTU) + contact status input x 3 points, pulse output, and alarm output
  • CC-Link communication + contact status input x 3 points, pulse output, and alarm output
  • 6 analog outputs, pulse output, and alarm output

specification

Specification

itemspecification
phase wire system・Single-phase 2-wire
, single-phase 3-wire
, and three-phase 3-wire
(setting switchable)
Voltage Input・AC110V
・AC220V
(setting switch)
Current Input・5A
・1A
(model designation)
Auxiliary power supply・AC85~264V or DC85~143V
・DC20~40V
・DC30~60V
(specify model)
External Operation Input2 points

Digital display

Measurement item (number of digits)Input Ratinginherent errorremarks
Current (3・4)0~1A・0~5A±0.5%Display unit A/kA switching
Line voltage (3, 4)0~150V・0~300V±0.5%Display unit V/kV switching
Phase voltage (3, 4)0~150√3V・0~300√3V±0.5%Display unit V/kV switching
Electricity (4)0~1kW・-1~0~1kW・0~2kW・-2~0~2kW±0.5%Display unit switchable between W, kW and MW,
negative display
Reactive Power (4)0~Lag1kvar・Lead1~0~Lag1kvar・0~Lag2kvar・Lead2~0~Lag2kvar±0.5%Display units: var, kvar, Mvar switchable,
with Lag and Lead display
Power factor (3)Lead50~100~Lag50・Lead0~100~Lag0(%)±2.0%Lag/Lead display,
1 decimal place
Electricity (6)Digital display:
multiplication factor x 1, x 10, x 100, x 1000
±2.0%

±2.5%

5 to 120% of rated current
(power factor = 1)10 to 120% of rated current
(power factor = 0.5)
Reactive energy (6)Digital display:
multiplication factor x 1, x 10, x 100, x 1000
±2.5%

±2.5%

±3.0%

10 to 120% of rated current
(power factor = 0)20 to 120% of rated current
(power factor = 0.866)

10% of rated current
(power factor = 0.866)

Frequency (3)45~65Hz・45~55Hz・55~65Hz・±0.5%1 decimal place
Demand current
Maximum demand current
(3/4)
0~5A±0.5%Demand time selection setting, heat conduction root calculation method
Demand power
Maximum demand power
(4)
0-1kW, 0-2kW±0.5%Demand time selection setting, heat conduction root calculation method
Current extension measurement (3, 4)0~5A・0~25A±8.0%Display unit A/kA switching
extended by 5 times (R phase only)
Harmonic current (3・4)Total RMS value:
0~1A, 0~5ATotal distortion factor:
0~100%
±2.5%Display unit A/kA switching,
R phase, S phase only measurement,
total RMS value, total distortion factor, each order RMS value, each order distortion factor, fifth order converted RMS value, fifth order converted distortion factor, distortion factor up to 50%
Harmonic voltage (3, 4)Total RMS value:
0 to 150V, 0 to 300VTotal distortion:
0 to 100%
±2.5%Display unit V/kV switch,
RS phase, ST phase only measurement,
total effective value, total distortion factor, each order effective value, each order distortion factor, fifth order converted effective value, fifth order converted distortion factor, distortion factor up to 50%
Zero-phase voltage (3, 4)

Maximum zero-phase voltage (3, 4)

EVT:
AC110V/AC190.5VZPD:
AC7V/AC7.6V
±1.0%
Io (4)AC0.8A±1.0%Display unit A
Ior (4)AC0.1A±10.0%Display unit A

Communication specifications

methoditemRating
RS-485 communicationInterfaceRS-485
Transmission distanceLess than 1km (maximum 32 cars)
communication speed1200・2400・4800・9600・19200bps
Transmission cableShielded twisted pair wire
(CPEV-S0.9φ)
Termination resistorBuilt-in 100Ω
(terminal short-circuited to turn on termination resistor)
Synchronization methodStart-stop synchronization method
Communication Control MethodPolling selection method (half-duplex)
Code usedASCII
Data format: Starbit1 bit
Data method: Data7-bit
Data format: Parity biteven number
Data format: Stop bit1 bit
RS-485 communication (Modbus)InterfaceRS-485 communication (Modbus)
Transmission distanceLess than 1km (maximum 32 cars)
communication speed1200・2400・4800・9600・19200bps
Transmission cableShielded twisted pair wire
(recommended: CPEV-S0.9φ)
Termination resistorBuilt-in 100Ω
(terminal short-circuited to turn on termination resistor)
Synchronization methodStart-stop synchronization method
Communication Control MethodPolling selection method (half-duplex)
Code usedRTU
Data format: Starbit1 bit
Data method: Data8-bit
Data format: Parity bitNone or even number or odd number
Data format: Stop bit1 or 2 bits
CC-Link communicationcommunication protocolCC-Link Ver1.1/Ver2 (8x mode)
communication speed156k・625k・2.5M・5M・10Mbps
Number of occupied stationsOccupies one remote device station
Configurable area codes1~64
Number of connectable devices42 units
(when configured with this unit only)
Word area
(CC-Link Ver1.1)
Send and receive 4 words each
(for analog data)
Word area
(CC-Link Ver2)
Send and receive 32 words each
(for analog data)
Bit area
(CC-Link Ver1.1)
32 bits for transmission and reception
(for contact data)
Bit area
(CC-Link Ver. 2)
256 bits for transmission and reception
(for contact data)
Contact status inputSame as auxiliary power supply
(operates when energized for 0.3 seconds or more, continuous energization possible)
Maximum input current is 6mA or less.