Suntest
Suntest GY Series GYMRS Probe

Manufacturer: Suntest Co.,Ltd
Model: GYMRS
Magnetostrictive Displaiacement Transducer
Model GY Series are “Displacement Transducers” employing magnetostrictive phenomena, especially the Wiedemann effect. An ultra-sonic wave is generated by a moving magnet operating near a magnetostrictive wave guide on which the sonic wave propagates up to the head of the transducer.
The propagation time is precisely measured by state of the art technology and then the absolute displacement transducer is operational.

[ Principle ]
The figure shows the fundamental principle of operation.
When a current pulse like A is given to the wave guide, it generates a circumferential magnetic field on the wave guide, then placement of the movable magnet (polarized axially) as shown, only the axial magnetic field of the magnet affecting the wave guide produces a resultant field as indicated by the dotted line.
The vector combination of these two fields produces torsional strain, a phenomenon known as the Wiedemann Effect.
It is a form of vibration and propagates along the wave guide in the form of a transverse ultra-sonic wave.
The GY series displacement transducers detect the propagation time of the ultra-sonic wave.
GYMRS Probe.
Thin head SSI output (detachable probe element)

Flat head SSI output sensor.
GYMRS probe outputs displacement of the magnet as SSI (Synchronous Serial Interface).
SSI is output of a serial communication-type and outputs the position data of 24〜27bit(Min. resolution 1μm (option 0.1μm)).
When using SSPC-03 of separate sale, you can convert SSI to parallel data. So you can get the data in the I/O unit.
The inside probe element can be detached from the outer housing, and with the captive software (GPM), zero and gain adjustment is possible at user side.
Specifications
| Non-linearity | ≦ ±0.025%FS (Typ.) |
|---|---|
| Resolution | 0.1mm〜0.1μm |
| Repeatability | ≦ 0.001% FS (≦Min. ±3μm ) |
| Temp. drift | ≦ ±20ppm FS/°C |
| Position (Std.) | SSI ( Synchronized Serial Interface) 、 24〜27bit、Binary(Std.) or Gray |
| Velocity (option) | not available |
| Alarm output | Open drain 50V 0.1A (for magnet missing) |
| Power supply | +24(±2)VDC (60mA) |
| Sampling frequ. (*) | Std. 1kHz ( total rod length : up to 1300mm ) |
| Operating temp | -20°C〜+75°C |
| Storage temp. | -40°C〜+75°C |
| Vibration | 15G(10〜100Hz) |
| Shock | 100G(2ms) |
| IP grade | IP67 (Rod Typ.) |
・The above mentioned accuracy applies to sensors with an effective stroke of 300mm or more.
・The specification of stroke less than 300mm is equal that of stroke 300mm.
(*) Sampling frequency can be increased up to 2 kHz (total rod length 700 mm or less).
(Depends on the sampling frequency of the upper side since it is synchronous).
Model No.

① Effective stroke
15〜7500mm
② Head dead zone
50: 50mm (Std.)
□: □mm (option)(specified by customers)
・Possible Min. length depends on the selected magnet or float.
③ Tip dead zone
□: 70mm/ 90mm/ 100mm (Std.)
| □ | tip DZ | magnet | float |
|---|---|---|---|
| 70 | 70mm | M2PN, M0SM, M0LM, M3, M11N, BA | F25N, F28N |
| 90 | 90mm | F28S, F30S | |
| 100 | 100mm | T144, T163 | F40S, F42S, F50S, F54S |
□: □mm(option)(specified by customers)
・Possible Min. length depends on the selected magnet or float.
④ Thread/Rod diameter
M :M24xP1.0, rod Φ10 (Std.)
N :M18xP1.5, rod Φ10
U :3/4-16UNF-3A, rod Φ10
M8 :M24xP1.0, rod Φ8
N8 :M18xP1.5, rod Φ8
U8 :3/4-16UNF-3A, rod Φ8
M14 :M24xP1.0, rod Φ13.8
Z :EF (flexible element) only (without outer housing)
⑤ Associated magnet or float
| magnet | float |
|---|---|
| M2PN :No.2PN(Std.) M0SM :No.ΦSPM M0LM :No.ΦLPM M3 :No.3 M11N :No.11N T144 :No.T14-M4 T163 :No.T16-M3 BA :No.2KYN-17-LG | F28S :Φ28 SS316L F30S :Φ30 SS316L F40S :Φ40 SS316(B) F42S :Φ43 SS316 F50S :Φ50 SS316L F54S :Φ54 SS304 F25N :RF-A10 plastic F28N :RF-A6 plastic |
・Selecting magnet from page 116-118(GG).
・Please consult our factory in case of requesting special magnet or float.
・This model code means only specifying associated magnet or float.
・Ordering magnet or float individually.
⑥ Cable connection
△G□F: pigtail / cable end : free
△G□A: pigtail / cable end : with connector for relay
(□: cable length(m)、Max.10m)(*)
(△: cable type
S:standard, H:high temp. cable, R:robot cable, UL : cUL cable)
(*) In case of cable 10m or more, please use extension cable.
・Please confirm extension cable on page 120〜122.
⑦ Resolution
D2: 0.1mm
D3: 0.05mm
D4: 0.01mm (Std.)
D5: 0.005mm
D7: 0.002mm
D8: 0.001mm
DF: 0.5μm
DG: 0.2μm
DH: 0.1μm
⑧ Linearity option
blank: No option required
L : Linearity correction option (corrected at room temperature)
⑨ Direction
D: When magnet moves toward tip, output increase
R: When magnet moves toward tip, output decrease
⑩ Number of bits
4: 24bit (Std.)
5: 25bit
6: 26bit
7: 27bit
⑪ Output code
B : Binary (Std.)
G : Gray
⑫ Synchronous
5S: Synchronous SSI
⑬ Option
blank : without option
SRT :SRT option (pigtail type only)
・Please confirm the details of SRT option on page 114.

Dimensions
Probe

Detachable probe element

Cable
| Wire color | Functions |
|---|---|
| red | +24VDC |
| white | 0V |
| blue | DATA+ |
| green | DATA- |
| brown | CLK+ |
| black | CLK- |
| yellow | Alarm |
- Shield should be connected to FG of user’s unit.
<Material>
Probe(Materials : Probe head : Al alloy, Probe rod : SS304)