Nachi NSPi Series Inverter Drive Hydraulic Unit

Made in: Japan
Manufacturer: NACHI
Model: NSPi Series (NSP-10E-15V*A*-21, NSP-10E-22V1A*-21, NSP-20E-15V1A*-21, NSP-20E-22V1A*-21)

Features of NSPi Series

If you want to save energy, then use NACHI hydraulic equipment. Just by Changing conventional hydraulic units to NSPi series inverter-driven hydraulic units Power Consumption 69% DOWN

Easy Operation and Reliable Performance

Immediate start just by turning on the power

The inverter drive NSPi unit can be started easily just by turning on the power.
Just push a single button to operate at maximum energy savings after pressure is adjusted.

Production lines keep running
Production lines continue running even if there is trouble with the inverter because it is based on our reliable NSP unit and keeps running as a regular NSP unit.

Perfomance

Energy-saving effect

Power Consumption Reduced by Approximately 69%
(as compared to NACHI-Fujikoshi’s standard hydraulic units while dwelling)
The base NSP unit consumes about 40% less energy than NACHI-Fujikoshi’s standard hydraulic units. By adding the inverter drive we increase energy savings to approximately 69% as compared to NACHI-Fujikoshi’s standard hydraulic units.

Power consumption while maintaining pressure

Power rate 40% down

As compared to NACHI-Fujikoshi’s standard hydraulic units, the NSP unit cuts 25% and the inverter drive NSPi unit cuts another approximately 40% from energy bills.

Annual energy cost

Reduces annual CO2 emissions by approximately two tons

The inverter drive NSPi unit emits about 42% less CO2 than NACHI-Fujikoshi’s standard hydraulic units.
Equivalent to two hectares of forest
Method for calculating energy costs and CO2 emissions

an annual operation time 8000hour electric power unit price 15yen/kWh
maintaining pressure 17houur/day CO2 Emission factors 0.555kgCO2/kWh
Discharge 5hour/day

*CO2 emissions factor: default value set by Ministry of Economy, Trade and Industry & Ministry of the Environment Ordinance Number 3, 2006.

Reduce increase in hydraulic fluid temperature

1.5°C increase in ambient temperature

The NSPi series benefits your entire system by lowering oil temperature to improve machining accuracy, lengthen the life of seals and hydraulic fluid, and reduce factory air conditioning costs.
Improve machining accuracy
Lengthen life of seals and hydraulic fluid
Reduce maintenance costs

Greatly reduce the volume of hydraulic fluid

Low Nois

53db. of the wonder
The noise when dwelling is as quiet as a relaxing coffee shop.
The inverter drive saves energy and increases comfort at the same time.
(6MPa while maintaining pressure NSP-10E-22V1A4-20)

Specifications

Power-supply voltage 3Ø AC200 to 240V, 50/60Hz(200V Class)
3Ø AC380 to 480V, 50/60Hz(400V Class)
Rated input current 9.7A/1.5kW, 13.4A/2.2kW(200V Class)
5.9A/1.5kW, 8.2A/2.2kW(400V Class)
Note) In the 400V grade the input current value for the fan cooler is not included.
Pressure adjustment range A2:1.5 to 4.0MPa
A3:3.5 to 6.0MPa
A4:5.5 to 8.0MPa
Discharge amount (no-load) 0A* : 14L/min
1A* : 28L/min
HYDRAULIC OILs Standard mineral-based hydraulic fluid (equivalent to ISO VG32)
OIL TEMPERATURE Use at temperatures below 60°C.
Color black (Semi-gloss)
ambient temperature / humidity 0 to 35°C/20 to 80%RH (No condensation)
(Keep the unit away from water-soluble cutting fluid mist. )

Mounting dimensions

Type Motor
(kW-P)
Measurment Approximate mass
(kg)
LA LB LC LD LE LF LG LH LI H L
NSP-10E-15V*A*-21 1.5-4 510 5 501 265 236 164 119 172 30 10L 8.5L 48
NSP-10E-22V1A*-21 2.2-4 540 35 521 256 174 129 55
NSP-20E-15V1A*-21 1.5-4 510 5 601 365 236 164 119 252 50 20L 16L 51
NSP-20E-22V1A*-21 2.2-4 540 35 621 256 174 129 58

·approximate mass, Does not include the hydraulic fluid

Explanation of model No

Hydraulic circuit diagram

Precautions for use

  • Turning the inverter on and off by cutting the main power supply (circuit breaker) significantly reduces the life of the inverter and should be limited to once an hour or less. Contact us if you need to start and stop operations frequently.
  • Do not change the inverter’s parameter settings.
  • Use a 1/2 inch diameter two meter long flexible hose rated for maximum 14 MPa working pressure to connect the hydraulic unit’s P port (discharge port) and the external manifold (or actuator).
  • Maximum peak pressure (set pressure + surge pressure) must be within 14 MPa. Install a relief valve on the hydraulic circuit side to cut surges if peak pressure is higher than 14 MPa.
  • Volume of leakage on external hydraulic circuits must be less than 1 L/min. Consult us if leakage on the external hydraulic circuit is greater than 1 L/min.
  • The volume of hydraulic fluid in the tank must stay within the range visible on the fluid level gauge (10L tank: approximately 1.5 L, 20L tank: approximately 4L).

 

REQUEST QUOTATION

PAYMENT

payment-methods

 

TOOLS & EQUIPMENT

Lifting
Eagle Clamp | Eagle Jack | Elephant | Endo Kogyo
Japan Clamp | Kanetec | Jung | KITO | Katsuyama Kikai
Kondotec | Miki Netsuren | Sanei Seiki | Taiyo

Hand Tools
Bix | Miyakawa | Nakatani Kikai | Ogura | Osakada Tool
Super Tool | TONE | Yutani

Tape
Kamoi | Kikusui | Misuzu | Nirei | Okamoto | Taiho | Teraoka

Measurement
Hasegawa | Kawaki | Kett | KGK | Line Seiki | Nagano Keiki
Niigata Seiki | Obishi Keiki | RSK | Ryoden Shonan | Sanko
Sanwa Supply | Showa Seisakusho | Showa Sokki
SK Sato | Tokyo Keiso | Tokyo Sokushin

Safety Tools
Fujii Denko | Shigematsu | Titan

Welding
Asahi Weldex | Daihen | Koike | Nissan Tanaka

Drilling
Dijet | Kansai Kogu | Nitto Kohki | Okazaki Seiko | Takeda

Chemical
Cemedine | DaitoNippon Grease | Taseto

Other Tools
Hammer Caster | Kitagawa | Matsuda Seiki | Misuz | Sanritsu
Sanyutec | Shizuoka Seiki | Toyo Kensetsu Kohki | Yamamoto
Yamari

PLANT FACILITIES

Facilities
Acokk | Bunkaboeki | Horiuchi | Konan | Murakoshi
Murakoshi Industries | Nesstech | Nihon Flux | Nikkin Flux
NFK | Omega System | Organo | Taiyo Parker | Toyo Mic

Pump
Dynaflo | Ebara | Honda Kiko | KyowaMusashino
Tsurumi

Valve
Astam | Kyowa Iron | Nachi | Nippon Daiya | Sawada
Wasino Kiki | Yoshitake

Electricity
Arkon | Asahi Bagnal | Gentos | Iwasaki | Kokosha | U_RD

CONSTRUCTION

Concrete Work
Daia | EXEN | Japan Life | Mikasa | Okasan Kiko | Taiheiyo

Railway Work
Kyoei | Sanwa Tekki | Teikoku | Toko

Scaffolding
Bullman | Okabe | Rikiman | Tsugaru

High Tension Bolt
Dong Ah | KPF | Nippon Steel Bolten | Nippon Fastener

Bolt & Nut & Washer
Hard Lock | Kishu Fastener | Matsukin | Mori Kozai
Nakaumi | Naniwa | Ogawa | Otani | Sudo | Toneji

STEEL MATERIAL

Steel & other Material
Dongil | JIS Standard | DSR | Sumitomo Wire | Winoa IKK

Pipe
Benkan

Return Top