AirTAC
AirTAC DPH Series Digital Display Pressure Sensor Analog Output
Product Made in Japan
Manufacturer: AirTAC Co., Ltd.
Model: DPH Series
Specification
Model | DPHN2(3)(B)-01 / DPHP2(3)(B)-01 / DPHN2(3)(B)-10 / DPHP2(3)(B)-10 | |
---|---|---|
Input power | Voltage | 12-24 VDC ± 10% Ripple(p-p) < 10% |
Current Consumption | 40mA or less | |
Pressure range | Fluid | Non-corrosive gas |
Measurement range | DPHN2(3)(B)-01/DPHP2(3)(B)-01 : -15psi~15psi | |
DPHN2(3)(B)-10/DPHP2(3)(B)-10 : -15psi~150psi | ||
Withstand pressure | DPHN2(3)(B)-01/DPHP2(3)(B)-01 : -15psi~22psi | |
DPHN2(3)(B)-10/DPHP2(3)(B)-10 : -15psi~175psi | ||
Measurement error | ±2%F.S., ±1 digit (Temperature: 25±3°C) | |
Repetitive accuracy | ±0.2%F.S. | |
Temperature error | ±3%F.S. (Base 25°C, Range 0 to 50°C) | |
Display | Type | 4-digit measurement, 3.5-digit setting |
Output | LCD Analog and Double row LCD display | |
Color | 2-color LCD (Red/Green) | |
Switch Output | Output model | Basic mode, Hysteresis mode, Window comparator mode, Suction check mode, Leakage mode |
Transistor output | NPN: Maximum applied voltage 30V/100mA, Retained voltage < 2V | |
PNP: Maximum applied voltage 30V/100mA, Retained voltage < 2V | ||
Analog Voltage Output | 1 to 5V ±3% F.S. (Minimum load impedance 1 kΩ) | |
Analog Current Output | 4 to 20mA ±3% F.S. (Range of Load impedance is 50 – 2600Ω) | |
Output-delay time | 2ms, 20ms, 100ms, 500ms, 1000ms, 2000ms | |
Pressure Unit | DPHN2(3)(B)-01 DPHP2(3)(B)-01 | kPa, kgf/cm², bar, psi, mmHg, inHg |
DPHN2(3)(B)-10 DPHP2(3)(B)-10 | MPa, kPa, kgf/cm², bar, psi, cmHg, inHg | |
Vibration resistance | 10 to 500Hz with 10mm Amplitude in X, Y, Z directions for 2hrs | |
Impact resistance | Maximum 100m/s², X, Y, Z directions 3 times each | |
Operating Temp. range | 0-50°C | |
Stored Temp. range | -20-65°C | |
Humidity range | 35%~80% RH (No condensation) |
Ordering Code
Dimensions
Accessories
No. | Item |
---|---|
A | Value up button |
B | Setting button |
C | Value Down button |
D | Pressure display area |
E | Set pressure display area |
F | Output 1 indicator light |
G | Output 2 indicator light |
H | Power and signal connector |
I | Pressure input |
1 | DC(+) input (Brown) |
2 | OUT1 (Black) |
3 | OUT2 (White) |
4 | Analog/Zero (Orange) |
5 | DC(-) input (Blue) |