It can calibrate the instrumental error of micrometers, the feed error of spindle screws (example 1), and the parallelism and flatness of the spindle and anvil every 1/4 rotation (example 2). It has a handle with high thermal insulation effect, so it can prevent the influence of heat from the human body. It can be used for in-house calibration of micrometers and vernier calipers to obtain and maintain ISO9000 series certification .
Precision and specifications
Nominal size mm | Gauge length mm | tolerance | Roundness and diameter variation | Hardness HRC |
---|---|---|---|---|
2.5–10.0 | 20 | ±0.3μm | 0.3μm | 58+ |
15.0 to 25.37 | ±0.5μm | 0.5μm |
Series Details
Set number | Nominal size mm | Number of sets | Price (yen) |
---|---|---|---|
EMC-1-10 | 2.50 5.00 5.12 5.25 5.37 5.50 10.00 15.00 20.00 25.00 |
Ten | 30,000 |
EMC-2-4 | 25.00 25.12 25.25 25.37 | Four | 30,000 |
EMC-3 | 2.50 5.00 5.50 6.00 6.50 7.00 10.00 15.00 20.00 25.00 |
Ten | 35,000 |
This product comes with an inspection report, calibration certificate, and traceability system diagram as standard.
Usage example
[Example 1]
● Measurement of micrometer instrument error and spindle screw feed error
By measuring 2.50 / 5.00 / 10.00 / 15.00 / 20.00 / 25.00 mm and comparing it with the actual measurement data, the instrument error of the micrometer can be calibrated.
[Example 2]
● Check the parallelism and flatness of the anvil and spindle every 1/4 rotation.