EXEN BCM1104A Blaster Control Panel
Products Made In Japan
Manufacturer: EXEN
Model: BCM1104A
A wide range of variation depending on the condition, and special specification is supported
This product is used for the following applications:
- 01.Environmental recycling plant: timer operation is performed for blaster installed in boiler facilities
- 02.Prevention of blockage in fine sand silo in ready-mixed concrete plant
- 03.Prevention of blockage in ready-mixed concrete silo in dam site
-
Features
Blaster control panel enables the automatic injection depending on injection cycle, and enables the injection by receiving external signal through non-voltage contact. Automatic type can switch between automatic and manual modes, and can make single-shot inject in manual mode. Selection can be made from a wide range of control panel series, such as the number of blasters, indoor/outdoor, input power of 100V/200V, switching between automatic and manual, manual only, etc. Manufacturing of special product is supported.
On-site manual type simple blaster control panel (BCM)
BCM (equipment side (manual) type) is a simplified control panel that allows the blaster injection only with a button on site only when needed, depending on the powder blockage situation.
Manual/automatic type blaster control panel (BCA)
For BCA, it is possible to select manual (machine side) and automatic (remote) operations by the select switch depending on the blockage situation. The manual operation allows the blaster injection only by the operation of push button on machine side. The automatic operation can be made by setting the injection cycle of individual ON and OFF timer.
1 cycle/recycle operation (model BCA)
For model BCA, it is possible to select manual or automatic (cycle/recycle (loop)) arbitrarily by the select switch, which allows operation depending on the blockage situation.
External operation (BCA)
Using external contact (non-voltage contact) enables the remote operation.
Free control is supported by built-to-order
Various combination of blasters can be used in built-to-order. Use in explosion-proof are supported in accordance with N2 (Nitrogen) filling specification.
Dimensions, installation, control panel
Product dimensional drawings
Product dimensional table
Model W H L W 1 H 1 L 1 a b c Фd A B t BCA1101A 400 300 200 – – – 450 200 50 11 500 44 6 BCA1102A 400 300 BCA1103A 500 550 600 BCA1104A 500 400 BCA1106A BCA5101A 400 300 406 330 222 450 200 500 BCA5102A 400 430 300 BCA5103A 500 505 550 600 BCA5104A 500 530 400 BCA5106A BCM1102A 300 300 – – – 350 200 400 BCM1104A 400 450 500 BCM5102A 406 330 222 BCM5104A (Imperial System)
Model W H L W 1 H 1 L 1 a b c Фd A B t BCA1101A 15.75 11.81 7.87 – – – 17.72 7.87 1.97 0.43 19.69 1.73 0.24 BCA1102A 15.75 11.81 BCA1103A 19.69 21.65 23.62 BCA1104A 19.69 15.75 BCA1106A BCA5101A 15.75 11.81 15.94 12.99 222 17.72 7.87 19.69 BCA5102A 15.75 16.93 11.81 BCA5103A 19.69 19.88 21.65 23.62 BCA5104A 19.69 20.87 15.75 BCA5106A BCM1102A 11.81 11.81 – – – 13.78 7.87 15.75 BCM1104A 15.75 17.72 19.69 BCM5102A 15.94 12.99 222 BCM5104A Specification
BCA
Model Control method Protection level Voltage Number of units
can be peratedPower
consumption
(W)Maximum Electric
Comsumption
(W)Timer’s
set timeWeight
(kg)BCA1101A Automatic control IP4X indoor type
wall tapestry typeShgle phase
AC 100V1 14 650 ON-Timer
0.1~1sOFF-Timer
0.05s~300h10 BCA1102A 2 21 12 BCA1103A 3 28 15 BCA1104A 4 35 18 BCA1106A 6 49 BCA5101A IP44 outdoor-type
wall tapestry type1 14 13 BCA5102A 2 21 15 BCA5103A 3 28 20 BCA5104A 4 35 23 BCA5106A 6 49 BCM1102A Manual control IP4X indoor type
wall tapestry type2 11 420 ON-Timer
0.1~1s8 BCM1104A 4 20 10 BCM5102A IP44 outdoor-type
wall tapestry type2 11 13 BCM5104A 4 20 (Imperial System)
Model Control method Protection level Voltage Number of units
can be peratedPower
consumption
(W)Maximum Electric
Comsumption
(W)Timer’s
set timeWeight
(lb)BCA1101A Automatic control IP4X indoor type
wall tapestry typeShgle phase
AC 100V1 14 650 ON-Timer
0.1~1sOFF-Timer
0.05s~300h22.0 BCA1102A 2 21 26.5 BCA1103A 3 28 33.1 BCA1104A 4 35 39.7 BCA1106A 6 49 BCA5101A IP44 outdoor-type
wall tapestry type1 14 28.7 BCA5102A 2 21 33.1 BCA5103A 3 28 44.1 BCA5104A 4 35 50.7 BCA5106A 6 49 BCM1102A Manual control IP4X indoor type
wall tapestry type2 11 420 ON-Timer
0.1~1s17.8 BCM1104A 4 20 22.0 BCM5102A IP44 outdoor-type
wall tapestry type2 11 18.7 BCM5104A 4 20 The value of power consumption indicates the maximum value including the power consumption of solenoid valve.
All models are built-to-order. For delivery time and price, contact EXEN.
All models with specification of single-phase 200V are manufactured. (Example of model: Model BCA1101 with specification of 200V->Model BCA1201)