Fluke 9142 Field Metrology Well

Manufacturer: Fluke Calibration
Model: 9142

Features

  • Lightweight, portable, and fast
  • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
  • True reference thermometry with accuracy to ±0.01 °C
  • On-board automation and documentation
  • Metrology performance in accuracy, stability, uniformity, and loading

9142

Specifications

SpecificationDetails
Temperature range at 23°C–25°C to 150°C (–13°F to 302°F)
Display accuracy±0.2°C full range
Stability±0.01°C full range
Axial uniformity at 40 mm (1.6 in)±0.05°C full range
Radial uniformity±0.01°C full range
Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes)±0.006°C full range
Hysteresis0.025
Operating conditions0°C to 50°C, 0% to 90% RH (non-condensing)
Environmental conditions (for all specifications except temperature range)13°C to 33°C
Immersion (well) Depth150 mm (5.9 in)
Insert OD30 mm (1.18 in)
Heating time16 min: 23°C to 140°C
23 min: 23°C to 150°C
25 min: –25°C to 150°C
Cooling time15 min: 23°C to –25°C
25 min: 150°C to –23°C
Resolution0.01°
DisplayLCD, °C or °F user-selectable
Size (H x W x D)290 x 185 x 295 mm (11.4 x 7.3 x 11.6 in)
Weight8.16 kg (18 lb)
Power requirements100 V to 115 V (±10%) 50/60 Hz, 635 W
230 V (±10%) 50/60 Hz, 575 W
Computer interfaceRS-232 interface
CalibrationNVLAP accredited calibration included
AutomationUse the 1586A Super-DAQ to automate temperature sensor calibration

 

Built-in reference thermometer readout accuracy (4-Wire Reference Probe)1±0.010°C at -25°C
±0.015°C at 0°C
±0.020°C at 50°C
±0.025°C at 150°C
±0.030°C at 200°C
±0.040°C at 350°C
±0.050°C at 420°C
±0.070°C at 660°C
Reference resistance range0 ohms to 400 ohms
Reference resistance accuracy20 ohms to 42 ohms: ±0.0025 ohms
42 ohms to 400 ohms: ±60 ppm of reading
Reference characterizationsITS-90, CVD, IEC-751, Resistance
Reference measurement capability4-wire
Reference probe connection6-pin Din with Infocon Technology
Built-in RTD thermometer readout accuracyNI-120: ±0.015°C at 0°C
PT-100 (JIS): ±0.02°C at 0°C
RTD resistance range0 ohms to 400 ohms
RTD resistance accuracy20 ohms to 25 ohms: ±0.002 ohms
25 ohms to 400 ohms: ±80 ppm of reading
RTD characterizationsPT-100 (385), (JIS), (3926), NI-120, Resistance
RTD measurement capability4-wire RTD (2-,3-wire RTD w/ Jumpers only)
RTD connection4 terminal input
Built-in TC thermometer readout accuracyType J: ±0.7°C at 660°C
Type K: ±0.8°C at 660°C
T: ±0.8°C at 400°C
Type E: ±0.7°C at 660°C
R: ±1.4°C at 660°C
Type S: ±1.5°C at 660°C
M: ±1.4°C at 660°C
Type L: ±0.7°C at 660°C
U: ±0.75°C at 600°C
Type N: ±0.9°C at 660°C
Type C: ±1.1°C at 660°C
TC millivolt range–10 mV to 75 mV
Voltage accuracy0.025% of reading + 0.01 mV
Internal cold junction compensation accuracy±0.35°C (ambient of 13°C to 33°C)
TC connectionSmall connectors
Built-in mA readout accuracy0.02% of reading + 2 mV
mA rangeCal 4-22 mA, Spec 4-24 mA
mA connection2 terminal input
Loop power function24 V DC loop power
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)±0.005% of range per °C

1. The temperature range may be limited by the reference probe connected to the readout. The Built-In Reference Thermometer Readout Accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors.
2. Measurement accuracy specifications apply within the operating range and assume 4-wires for PRTs. With 3-wire RTDs add 0.05 ohms to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires.

 